Academic literature on the topic 'Sistema tomografico'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Sistema tomografico.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Sistema tomografico"
Rutkauskaitė, Dileta, Gediminas Navickas, Eligijus Poškus, and Kęstutis Strupas. "RETROREKTINIŲ-PRESAKRALINIŲ DARINIŲ RADIOLOGINĖS DIAGNOSTIKOS IR GYDYMO PATIRTIS VUL SANTARIŠKIŲ KLINIKOSE 2004–2015 M." Medicinos teorija ir praktika 21, no. 4.1 (September 10, 2015): 606–11. http://dx.doi.org/10.15591/mtp.2015.095.
Full textSouza, Giordana Salvi de, Ana Paula Pastre Froner, and Ana Maria Marques da Silva. "Doses em tomografia computadorizada de crânio: impacto do uso do controle automático de exposição." Revista Brasileira de Física Médica 11, no. 2 (December 4, 2017): 21. http://dx.doi.org/10.29384/rbfm.2017.v11.n2.p21-24.
Full textAlmeida Junior, José Guiomar de, Maria Lúcia de Oliveira Santos, Telmo Pimentel do Vabo, Klezer Gaspar Carvalho da Silva, Alessandro Severo Alves de Melo, Luiza Beatriz Melo Moreira, Maria Angélica Soares Muniz, Alexandre Szerman, and Edson Marchiori. "Carcinoma de células transicionais do trato urinário: aspectos da tomografia computadorizada." Radiologia Brasileira 36, no. 1 (January 2003): 11–15. http://dx.doi.org/10.1590/s0100-39842003000100005.
Full textSantos, Diana Lima dos, Handerson Jorge Dourado Leite, Davide Rasella, and Sebastião Antonio Loureiro de Souza e. Silva. "Capacidade de produção e grau de utilização de tomógrafo computadorizado no Sistema Único de Saúde." Cadernos de Saúde Pública 30, no. 6 (June 2014): 1293–304. http://dx.doi.org/10.1590/0102-311x00140713.
Full textAihara, André Yui, Artur da Rocha Corrêa Fernandes, Christian Munia Viertler, and Jamil Natour. "Tomografia multi-slice no sistema músculo-esquelético." Revista Brasileira de Reumatologia 43, no. 6 (December 2003): 372–76. http://dx.doi.org/10.1590/s0482-50042003000600010.
Full textReis, Elton Fialho dos, Carlos Ernesto G. R. Schaefer, Haroldo Carlos Fernandes, João de Mendonça Naime, and Eduardo Fontes Araújo. "Densidade do solo no ambiente solo-semente e velocidade de emergência em sistema de semeadura de milho." Revista Brasileira de Ciência do Solo 30, no. 5 (October 2006): 777–85. http://dx.doi.org/10.1590/s0100-06832006000500003.
Full textRolim, Cristina Lúcia Rocha Cubas, and Monica Martins. "O uso de tomografia computadorizada nas internações por Acidente Vascular Cerebral no Sistema Único de Saúde no Brasil." Revista Brasileira de Epidemiologia 15, no. 1 (March 2012): 179–87. http://dx.doi.org/10.1590/s1415-790x2012000100016.
Full textSouza, Luís Ronan Marquez Ferreira de, Salomão Faintuch, Daniel Bekhor, Dario Ariel Tiferes, Suzan Menasce Goldman, and Jacob Szejnfeld. "Avaliação da concordância interobservador na análise da tomografia computadorizada sem contraste no diagnóstico da urolitíase em pacientes com cólica renal aguda." Radiologia Brasileira 39, no. 5 (October 2006): 341–44. http://dx.doi.org/10.1590/s0100-39842006000500008.
Full textFaçanha, Mônica Cardoso. "Casos de cisticercose em pacientes internados pelo Sistema Único de Saúde: distribuição no Estado do Ceará." Revista da Sociedade Brasileira de Medicina Tropical 39, no. 5 (October 2006): 484–87. http://dx.doi.org/10.1590/s0037-86822006000500012.
Full textAdomaitienė, Irina, Reda Černiauskaitė, Artūras Samuilis, and Robertas Adomaitis. "Prostatos magnetinio rezonanso tomografijos tyrimo indikacijų ir atlikimo metodikų analizė Vilniaus universiteto ligoninės Santariškių klinikose 2006–2014 metais." Medicinos teorija ir praktika 21, no. 2.2 (February 26, 2015): 271–76. http://dx.doi.org/10.15591/mtp.2015.044.
Full textDissertations / Theses on the topic "Sistema tomografico"
Fusillo, Elena. "Un sistema tomografico trasportabile per indagini in situ di opere d’arte." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2018. http://amslaurea.unibo.it/15417/.
Full textPedrazzini, Filippo. "Sviluppo di un sistema tomografico con tubo a raggi x da 300 kv: progettazione e test preliminari." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2013. http://amslaurea.unibo.it/6145/.
Full textMorroni, Paolo. "Progettazione e sviluppo di un collimatore multi-slit per un sistema tomografico cone-beam con raggi X di alta energia." Master's thesis, Alma Mater Studiorum - Università di Bologna, 2015. http://amslaurea.unibo.it/8351/.
Full textKesheh, Foad Mobini. "Desenvolvimento de sistema eletrônico para tomografia de indução magnética." Universidade do Estado de Santa Catarina, 2011. http://tede.udesc.br/handle/handle/1912.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior
Magnetic induction tomography is a contactless conductivity imaging technique. This technique uses a magnetic field generator (usually a coil) to induce Eddy currents in the target object and several magnetic sensors (usually coils as well) that capture the magnetic field generated by these induced currents. The measurements obtained by these sensors can be used to construct a conductivity image of the space inside the tomograph. The purpose of this dissertation is to develop an electronic system for magnetic induction tomography. The main objective is to detect the magnetic field generated by the induced Eddy currents measuring the disturbance on the phase of the sensor s signal when a conductive object is placed inside the tomograph. Coils were used as magnetic field sensors and generator. The frequency used to generate the excitation fields and also on phase detection circuit were 10.7 MHz. The system is capable to measure only one sensor and enable only one generator at a time. A system with 16 sensors and 16 generators was achieved through multiplexing. All the electronics were analyzed and results are shown on this dissertation. Also a preliminary tomograph prototype was build and some measurements were taken and compared to measurements done by commercial electromagnetic sensor and a scope. For a 1 S/m sample the average square error on the measurements compared to simulations was 0.41°.
A tomografia por indução magnética é uma técnica que possibilita o mapeamento da condutividade de uma determinada região sem um contato elétrico. Essa técnica utiliza um gerador de campos magnéticos (geralmente uma bobina) para induzir correntes Eddy em um objeto e vários sensores magnéticos (também usualmente bobinas) que capturam o campo magnético gerado por essas correntes induzidas. As medidas obtidas por esses sensores podem ser usadas para construir uma imagem da condutividade no espaço no interior ao tomógrafo. A proposta desta dissertação é desenvolver um sistema eletrônico para tomografia por indução magnética. O principal objetivo é detectar o campo magnético gerado pelas correntes Eddy induzidas medindo o distúrbio provocado na fase dos sinais dos sensores quando um objeto condutivo é colocado no interior do tomógrafo. A frequência do sinal utilizado para excitação da amostra foi de 10,7 MHz. O sistema construído é capaz de medir a fase de uma combinação de bobina sensora e geradora de campo por vez. Para medir 16 sensores e controlar 16 geradores foram utilizadas técnicas de multiplexação. Toda a eletrônica construída foi analisada e os resultados são mostrados nesta dissertação. Também foram feitas medições utilizando um protótipo preliminar de tomógrafo e essas medidas foram comparadas às medidas realizadas utilizando osciloscópios e um sensor de campo magnético comercial. Para uma amostra de 1 S/m o erro médio quadrático máximo nas medidas quando comparadas com as simulações foi de 0,41°.
Azevedo, Filho Azamor Cirne de. "Desenvolvimento de um sistema de tomografia capacitiva para processos multifasicos." [s.n.], 2002. http://repositorio.unicamp.br/jspui/handle/REPOSIP/263381.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica
Made available in DSpace on 2018-08-02T07:43:28Z (GMT). No. of bitstreams: 1 AzevedoFilho_AzamorCirnede_D.pdf: 22444366 bytes, checksum: d02c293148932683939acd13b1b26459 (MD5) Previous issue date: 2002
Resumo: Este trabalho apresenta o desenvolvimento de um sistema de tomografia capacitiva aplicado ao estudo de processos multifásicos. A pesquisa se inicia com uma revisão da literatura sobre tomografia. Uma análise através de elementos finitos é realizada de forma a oferecer dados para a otimização do sensor de capacitância e para uma análise comparativa com os resultados experimentais. A reconstrução de imagens de diversos padrões de escoamento nessa análise numérica, através do método de retro-projeção-linear, permite verificar a adaptabilidade de vários parâmetros, que contribuíram para a qualidade das imagens, recomendando sua aplicação no procedimento experimental. A parte eletrônica do sistema tomográfico inclui um transdutor de capacitância associado a um circuito de multiplexagem de sinais, que permite o chaveamento das medidas via computador. O sensor de capacitância utilizado constitui-se de um tubo de acrílico com oito eletrodos localizados na parede externa do tubo. A fração de vazio é obtida através de um sistema eletromecânico de medição. A qualidade das imagens reconstruídas a partir de testes experimentais nas composições ar-água, ar-nylon e água-nylon, em diversas frações de vazio, atesta a validade do sistema tomo gráfico desenvolvido
Abstract: This work presents the development of a capacitive tomography system to the study of multiphase processes. The research starts with a literature review about tomography. A finite element analysis is accomplished to offer data for the optimization of the capacitance sensor and for a comparative analysis with the experimental results. The image reconstruction of several flow patterns in the numerical ana1ysis through the linear-back-projection method asserts the adaptability of various parameters which have contributed to the quality of the images, attesting its application in the experimental procedures. The e1ectronic part of the tomographic system inc1udes a capacitance transducer associated to a signal multiplex circuitry, controlled by computer. The capacitance sensor consists of eight electrodes mounted circunferentially around a perspex pipe. The void fraction is obtained through an electromechanical device. The quality of the reconstructed images of experimental data in air-water, air-nylon and water-nylon compositions, for several different void fractions, attests the validity of the developed tomographic system
Doutorado
Termica e Fluidos
Doutor em Engenharia Mecânica
Cardi, Riccardo. "Tomografia da analisi di rumore sismico nell'Italia settentrionale." Master's thesis, Alma Mater Studiorum - Università di Bologna, 2015. http://amslaurea.unibo.it/8347/.
Full textBertolo, Antonio Carlos Nunes. "Avaliação do desempenho de um sistema de tomografia PET com geometria elipsoidal." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/59/59135/tde-24072014-150954/.
Full textAmong the diagnostic imaging techniques, in Nuclear Medicine, have been prominent in Positron Emission Tomography (PET). PET provides functional images of the region or organ of interest, allowing diagnostic of various diseases and also a mapping of the development or regression of the same. Current PET systems feature blocks arranged in circular geometry crystals, but the search for new arrangements, in different geometries, is relevant because it can provide a better performance of these scanners. The objective of this study is to evaluate the performance of a PET system consisting of blocks of crystals ellipsoidal arrangement. For this study, we used the GATE simulation environment for emission tomography that presented satisfactory results compared to the devices used in the clinical routine. This way we prepared two PET systems, the first one containing 46 blocks of crystals arranged in a circular geometry, where the opposite detectors were separated by a distance of 816.4 mm in the transaxial direction. In the second case, we used 36 blocks of crystals arranged in an elliptical geometry, where the detectors are separated a distance of 500 mm in the vertical direction and 816.4 mm in the horizontal direction. After the simulations were performed, the validation tests for sensitivity, scatter fraction, NEC (Noise Equivalent Count Rate) and Spatial Resolution were made, to finally evaluate and compare the performance of the PET system for both proposed geometries. The tests were made accordingly to specified NEMA NU 2-2007 standard. For the sensitivity test, with the phantom located in the center of FOV transaxial of the tomography, we obtained a gain in PET system with elliptical geometry of 28.7% compared to the conventional system, the circular geometry. For the phantom shifted to 10 cm from the center of the transaxial FOV, the sensitivity of PET elliptical system was 26.2% higher than in the circular. The acquisition time for each simulation in this test was 400 s. For Scatter Fraction test and NEC, were made 33 simulations for each geometry, varying the time of acquisition and activity. The scatter fraction in the elliptical geometry was 35,5% and 34,6% in the circular geometry. In the circular geometry, NEC curve reaches its peak in 259.3 kcps at an activity concentration of 34.1 kBq ml-1, for the elliptical geometry, the maximum peak is reached at 239.1 kcps at an activity concentration of 24.8 kBq ml-1. For the spatial resolution test we used a point source containing 18F with 4 MBq activity and acquisition time of 200 s. The measurements were acquired in three transaxials positions (x,y) in the center of FOV and, shifted in ¼ of the center of the FOV, summarizing 6 measurements for each geometry. For each one of these 6 measurements, we found the FWHM (Full width at half-maximum amplitude) and the FWTM (Full width at tenth-maximum amplitude) in the three axis (x,y,z), in this way, for each proposed geometry, we obtained 18 values of FWHM and 18 values of FWTM. The elliptical geometry showed improvement in the spatial resolution in FWHM in 4 of the 18 resolution values. For the FWTM, the elliptical geometry showed improvement in 8 of 18 resolution values. Regarding the FWHM, where there was an improvement in spatial resolution, we obtained the average gain of 18,7%. For the losses, in spatial resolution was an average of 43,26%. For the FWTM, the improvement in spatial resolution was an average percentage of 12,09%, while the loss of resolution had the average percentage of 45,59%. It can be concluded that the proposed geometry showed some advantages regarding the traditional geometry. In the elliptical geometry there is one reduction of 10 blocks of crystals in relation to the circular geometry, which possibly can cut fabrication costs of the tomography. Regarding to sensibility, there is a significant improvement for the new geometry, as well as one reduction of the activity concentration in which the tomography reaches the best performance, although the occurrence of a slight fall in the counts in the elliptical system. This reduction in the activity concentration can help to reduce the test time and the use less radioactive material, reducing the risk for the patients and the test costs, as well as improving the number of tests in the same period of time. The scattering fraction in the elliptical system is slight higher to the circular system. The major loss in the elliptical PET system is the spatial resolution, where there was not improvement for the great fraction of the obtained measurements, requiring some modifications that can be made, in special, in the crystal blocks arrangement. It is believed that some modifications to the angle of the detectors and in the formation of the coincidences can improve the resolutions and NEC.
Stelzer, Murilo [UNESP]. "Biosusceptometria de corrente alternada: tomografia, validação e avaliação da motilidade fúndica gástrica." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/100599.
Full textO estudo da atividade do sistema digestório apresenta vários desafios, pois para termos medidas eficientes do seu funcionamentos as técnicas atualmente aplicadas ou são invasivas ou apresentam o uso de radiação ionizante, o que pode causar desconforto ou outros problemas ao individuo. ABiosusceptometria de Corrente Alternada (BAC), tem sido utilizada com sucesso no estudo da motilidade do trato gastrintestinal, sem a necessidade de radiação ionizante e sem ser invasiva.Essatese foi desenvolvida em três partes, com cada parte representando um trabalho, no primeiro foi estudado aOscilação Tônica no Estomago Proximal, no segundo foi feita a validação da BAC in vitro e in vivo como um método biomagnético para registrar contrações gástricas e finalmente no terceiro foi iniciado o desenvolvimento de uma nova instrumentação de modo a permitir a obtenção de imagens tomográficas utilizando a BAC. Desta forma, este trabalho apresenta estudos de validações da BAC para análise das atividades de contração tônica e fásica do estômago e de emprego como técnica tomográfica
The evaluation of gastric-intestinal activity presents a lot of challenges, because, the techniques to obtain efficient measures or is an invasive technique or it makes use of ionizing radiation, what could cause some discomfort or another problems related to the radiation. The Alternated Current Biosusceptometry (ACB) has been utilized with success, in the gastricintestinal activity studies, without the necessity of ionizing radiation and it isn´t a invasive method. This thesis has been developed in three parts, in the first part was studied the stomach proximal tonic oscillation, in the second was studied the validation of theACB method in vitro and in vivo as a biomagnetic method to register the gastric contractions, and finally the third, it was started the development of a new instrumentation capable of obtain tomography images by means of BAC
Tambellini, Flavio. "Estudo experimental e numerico da tomografia eletrica aplicada a sistemas bifasicos." [s.n.], 1999. http://repositorio.unicamp.br/jspui/handle/REPOSIP/263387.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica
Made available in DSpace on 2018-07-25T04:14:28Z (GMT). No. of bitstreams: 1 Tambellini_Flavio_D.pdf: 10882636 bytes, checksum: 4cd40929cd4ea82a33b7db9c8c968bf0 (MD5) Previous issue date: 1999
Resumo: o objetivo principal deste trabalho é fazer uma análise da tomografia de capacitância elétrica aplicada ao sistema bifásico, onde os componentes são ar e água, visando obter a reconstrução de imagem deste sistema. A tomografia de capacitância é constituída de um sensor com Seletrodos localizados em tomo de um tubo de acrílico e um transdutor eletrônico baseado em corrente alternada, cuja frequência de excitação pode atingir até 16 MHz. Foi feita a calibração do transdutor eletrônico e esta comparada com as curvas teóricas. Testes experimentaise simulações numéricas foram realizados, sendo os resultados comparados para frações de líquido variando de 0,1 a 0,95. A imagem foi reconstruída usando o algoritmo de retro-projeção linear, juntamente com a utilização da técnica de filtro para melhorar a imagem reconstruída e com uma estimativa da fração de líquido, obtida a partir de uma correlação entre a fração de líquido volumétrica e as capacitâncias experimentais. As informações necessárias para o algoritmo são as medidas experimentaisde capacitância, a fração de líquido estimada e a distribuição de sensibilidade, sendo esta última, obtida a partir de simulações numéricas. Os resultados são apresentados, as limitações descritas e propostas de melhoria para trabalhos futuros apresentadas
Abstract: The main objective ofthis work is the analysis ofthe electrical capacitance tomography for imaging of two-phase system, where the components are water and air. The capacitance tomography is consists by a sensor built with eight electrodes around an insulating pipe. An electronic transducer based in alternated current was developed to support excitation frequency up to 1611Hz. The calibration of the electronic transducer was made and compared with the theoretical curves. Numerical and experimental tests were made and the results compared for liquid fractions ranging from 0,1 to 0,95. The image was reconstructed using the linear back projection algoritm. A filtering technique was applied to the algoritm to improve the image quality. A liquid fraction estimative was obtained from the correlation of volumetric liquid fraction and experimental capacitances. The necessary information to the algoritm are the experimental measurements of capacitance, the estimated liquid fraction and sensitivitydistribuition. The results are shown, the limitationsare described and the improvement ofthis technique to the future works are indicated.
Doutorado
Termica e Fluidos
Doutor em Engenharia Mecânica
Reina, Thamiris Rosado. "Avaliação de sistemas de controle automático de exposição em tomografia computadorizada." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/43/43134/tde-28112014-152409/.
Full textThe development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AEC-system. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without compromising the diagnostic image quality.
Conference papers on the topic "Sistema tomografico"
Carvalho, Edelson, and Edson Carvalho. "Classification of CT images in COVID-19 and Non-COVID-19 using CNN to extract features and multiple classifiers." In Escola Regional de Computação Ceará, Maranhão, Piauí. Sociedade Brasileira de Computação - SBC, 2020. http://dx.doi.org/10.5753/ercemapi.2020.11493.
Full textAlonso Martins, Guilherme, Raquel Goncalves, and STELLA STOPA ASSIS PALMA. "INTERFERÊNCIAS DA MEDULA, DE NÓS E DO SISTEMA DE INTERPOLAÇÃO EM IMAGENS DE TOMOGRAFIA ULTRASSÔNICA." In XXIV Congresso de Iniciação Científica da UNICAMP - 2016. Campinas - SP, Brazil: Galoa, 2016. http://dx.doi.org/10.19146/pibic-2016-50987.
Full textSilva, N., K. Blane, and F. Y. Hiodo. "SISTEMA DIGITAL DE AQUISIÇÃO DE DADOS PARA CAMINHAMENTO E TOMOGRAFIA GEOELÉTRICA, USANDO MICROCONTROLADOR- PROJETO E CONSTRUÇÃO." In 8th International Congress of the Brazilian Geophysical Society. European Association of Geoscientists & Engineers, 2003. http://dx.doi.org/10.3997/2214-4609-pdb.168.arq_503.
Full textBraga, Mateus Figueiredo, Rui de Barros Correia-Filho, and Jorge Luiz Silva Araujo-Filho. "A IMPORTÂNCIA DE EXAMES DE IMAGEM EM PACIENTES COM TOXOPLASMOSE CEREBRAL E DIAGNÓSTICO DE AIDS: REVISÃO BIBLIOGRÁFICA." In I Congresso Brasileiro de Parasitologia Humana On-line. Revista Multidisciplinar em Saúde, 2021. http://dx.doi.org/10.51161/rems/710.
Full textAndrade Guimarães, Marjory Caroline, Taís Maria Araújo, Meila Cátia Castro, and Thalis Leon Ávila Saint Yves. "Programa de Otimização de Doses em Tomografia Computadorizada em um hospital de grande porte do Leste Mineiro." In Congresso Internacional de Qualidade em Serviços e Sistemas de Saúde. São Paulo - SP, Brazil: Galoa, 2017. http://dx.doi.org/10.17648/qualihosp-2017-69489.
Full textDe Azevedo, Saulo Bueno, Gean Scherer da Silva, Gabriela Kohl Hammacher, and Natália Gonçalves Rengel. "MANEJO DE INFECÇÃO POR TOXOPLASMOSE NO SISTEMA NERVOSO CENTRAL DE PACIENTES HIV POSITIVO." In I Congresso Brasileiro de Parasitologia Humana On-line. Revista Multidisciplinar em Saúde, 2021. http://dx.doi.org/10.51161/rems/689.
Full textHoroz, Muhammed Alperen, and Seda Arslan Tuncer. "Bilgisayarlı Tomografi Görüntülerini Kullanarak Covid-19 Hastalığının Derin Öğrenme Teknikleriyle Tespiti." In International Students Science Congress. Izmir International Guest Student Association, 2021. http://dx.doi.org/10.52460/issc.2021.021.
Full textMacedo, Victória. "HIPERALDOSTERONISMO EM FELINOS." In I Congresso On-line Nacional de Clínica Veterinária de Pequenos Animais. Revista Multidisciplinar em Saúde, 2021. http://dx.doi.org/10.51161/rems/1905.
Full textMachado, Polyana de Paula Mendes, Cristiano Salles Rodrigues, Bruna Lahud Abreu Netto, Fernanda Fernandes Figueira, and Karolinne Rangel Riscado Arruda. "Fibrossarcoma ovariano: apresentação de caso e revisão da literatura." In 44° Congresso da SGORJ - XXIII Trocando Ideias. Zeppelini Editorial e Comunicação, 2020. http://dx.doi.org/10.5327/jbg-0368-1416-2020130243.
Full text