Dissertations / Theses on the topic 'Sistemas elétricos de potência'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Sistemas elétricos de potência.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Silva, Lazaro Eduardo da. "Tecnologias WEB aplicadas aos sistemas elétricos de potência." Universidade de São Paulo, 2010. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-04102010-153801/.
Full textThe use of digital equipment and data communication for the connection of the devices in an electric power substation provides the implementation of new technologies to improve and upgrade the potentialities of control and supervision of an electrical power system. The utilities demand high investments in the establishment and implementation of supervision, control and data acquisition systems. Based on these systems, it is possible to visualize a map of the electrical network, the installation points of digital relays and the status of their functions, making it possible the diagnosis and control of such equipment. The World Wide Web started a convenient access to information due to the friendly interface with the user. The implementation of a supervising and control system using free web technologies can, in a competitive cost, join data which are geographically available to an ergonomic computational platform and also provides access to the users from any device connected to the web. As a result of this work, a supervision Web control System of a typical bay with a simple interface was set up, as well as the development of reports and announcement of events. A second network supervision system for cutting load and for power reestablishment, known as regional load relief scheme, was implemented. Finally, a voltage and frequency data acquisition system from a power quality equipment with time varying graphics was developed as well as a implementation of a multiple neural perception net (Time Delay Neural Network) in order to predict future values of the frequency. The supervision and control applications were developed with web technologies and tested using an intranet in order assure the application on the electrical power system, which can be accessed by a standard browser. It is relevant to mention that the whole system was tested in actual equipment which belongs to a laboratorial structure available to the post graduation students at the University of São Paulo, School of Engineering of São Carlos, Power Systems Laboratory where two substations with commercial digital relays are simulated and interconnected by a fiber optics backbone and also connected to the local laboratory network which allows remote access to the equipment. Such system as set up in a web platform that can add resources which are distributed in the development of a friendly and intuitive interface in addition to the availability of access to the information from any point connected to the web.
Silva, Roberval Madeira da. "Análise de estabilidade transitória na otimização de sistemas elétricos de potência." reponame:Repositório Institucional da UnB, 2009. http://repositorio.unb.br/handle/10482/22295.
Full textSubmitted by Camila Duarte (camiladias@bce.unb.br) on 2017-01-26T17:10:30Z No. of bitstreams: 1 2009_RobervalMadeiraDaSilva.pdf: 1848670 bytes, checksum: 0aad4f72191abc216c7f7112596179ac (MD5)
Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2017-01-29T10:43:00Z (GMT) No. of bitstreams: 1 2009_RobervalMadeiraDaSilva.pdf: 1848670 bytes, checksum: 0aad4f72191abc216c7f7112596179ac (MD5)
Made available in DSpace on 2017-01-29T10:43:00Z (GMT). No. of bitstreams: 1 2009_RobervalMadeiraDaSilva.pdf: 1848670 bytes, checksum: 0aad4f72191abc216c7f7112596179ac (MD5)
Esta dissertação apresenta uma metodologia para associação de estudos de estabilidade transitória de ângulo de rotor com estudos de otimização de sistemas elétricos de potência. Nesta metodologia, são alterados, nas restrições do Fluxo de Potência Ótimo (FPO), os limites de potência ativa do(s) gerador(es) previamente identificado(s) através do cálculo da diferença angular entre cada gerador e o Centro de Inércia (Cl), na condição préperturbação. O FPO é utilizado para calcular o despacho que resulte no menor valor de perdas elétricas na transmissão, do ponto de vista estático. Em seguida, são realizadas diversas simulações de estabilidade transitória, avaliando o comportamento dos ângulos de rotor frente aos critérios de segurança dinâmica estabelecidos. Caso os critérios de segurança sejam violados, será necessário repetir a execução do FPO até que seja encontrado um ponto de operação que atenda aos critérios do FPO e aos critérios de segurança dinâmica. Com o cálculo da diferença angular entre os geradores e o Cl, a repetição do FPO deixa de utilizar o método de “tentativa e erro”, uma vez que é possível estabelecer o sentido da variação na potência ativa do(s) gerador(es) mais crítico(s). Os geradores que possuem maior defasagem angular em relação ao Cl terão seu despacho de potência ativa restringido a valores próximos ao seu limite inferior, nas situações em que o ângulo do gerador for maior que o ângulo do Cl, ou ao seu limite superior (ângulo do gerador menor que o ângulo do Cl). Esta metodologia foi testada em uma rede de 9 barras e em um sistema real de 41 barras.
This dissertation presents a methodology to associate angle transitory stability analysis with electric power system optimization studies. Whenever dynamic security criteria are violated in a pre-disturbance condition, the active power generation capacity constraints are modified in the optimal power flow (OPF) for generators previously selected. The selection is based on the calculation of the angular displacement between each generator and the Inertial Center (IC). The OPF is used for dispatch calculation which results in lowest transmission losses, concerning the static point of view. Then, several transitory stability simulations are accomplished to evaluate the rotor's angle behavior in relation to established dynamic security criteria. In the occurrence of security criteria violations, a new optimal dispatch is calculated, and the process is repeated until reaching an operation point with no violations. Once the presented methodology makes use of angular displacement calculations to select which generators are candidates to solve the security problem, the usual empiric check-and-bound methods are not utilized. The method presented in this work allows to identifying the generators with greater angular displacements, choosing them and changing their active power constraint. The constraint is changed to a value close to the generator’s lower limit of generation capacity if the generator's angle is larger than the IC's angle. On the contrary, the generator's active power constraint is changed to its upper generation capacity limit. The methodology was tested with a 9-bus network and a real 41-bus system.
Almeida, Carlos Frederico Meschini. "Fontes distribuídas de harmônicos em sistemas elétricos de potência." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/3/3143/tde-22032012-120241/.
Full textThe growing rate of harmonic generation present in the electric power systems has gained special attention in the planning process of power networks. The major factor that contributed for this new context is the increasing harmonic generation observed in regions that did not use to represent any concern in the past. One of the main causes for this new trend is the distributed characteristic of the harmonic generation. In this new environment, sophisticated methods and models have become necessary, in order to precisely represent the electric elements behaviour and to accurately evaluate the systems performance. As a result, the research work presented in this thesis focused in three different topics, in order to provide contributions that would lead to a more accurate performance evaluation of the power networks and that would provide results closer to the values found in the field: Aggregate Load Modeling; Network Equivalents; Harmonic State Estimation. These contributions would allow the consideration of aspects that normally are ignored in the harmonic assessment of power systems. Consequently, the evaluation of the impacts caused by the distributed generation of harmonics becomes more accurate.
Marchesan, Gustavo. "Estimadores de frequência aplicados a sistemas elétricos de potência." Universidade Federal de Santa Maria, 2013. http://repositorio.ufsm.br/handle/1/8523.
Full textA estimação de frequência é um problema muito estudado em diversas áreas, dentre elas a dos sistemas elétricos de potência. Inúmeras metodologias foram propostas para esse fim, sendo que a maioria delas apresenta bom desempenho quando o sinal não está distorcido por componentes harmônicas ou ruídos. Este trabalho propõe duas novas metodologias fundamentadas em Redes Neurais Artificiais, de modo a estimar a frequência. Elas utilizam a transformada de Clarck para gerar um fasor que representa o sinal trifásico do sistema. Na primeira metodologia, esse fasor é normalizado e alimenta a Rede Neural de Regressão Generalizada, que faz a ponderação dos valores. Ao final, obtém-se um fasor em que ruídos e harmônicas são atenuados. A saída da rede neural é, então, utilizada para o cálculo da frequência do sistema elétrico. A segunda metodologia utiliza a Rede Neural Linear Adaptativa. Neste trabalho, também são testadas, para uso em sistemas elétricos de potência, diversas metodologias propostas em outras áreas de conhecimento, tais como radar, sonar, comunicação, biomedicina e aviação. São elas: Lavopa (proposta por Lavopa et al. 2007), Quinn (proposta por Quinn, 1994), Jacobsen (proposta por Jacobsen e Kootsookos, 2007), Candan (proposta por Candan, 2011), Macleod (proposta por Macleod, 1998), Aboutanios (proposta por Aboutanios, 2004), Mulgrew (proposta por Aboutanios e Mulgrew, 2005), Ferreira (proposta por Ferreira 2001) e DPLL (proposta por Sithamparanathan, 2008). Com exceção da DPLL, os demais métodos são fundamentados na transformada discreta de Fourier e buscam encontrar o pico do espectro de frequências, para, então, encontrar a frequência fundamental. As nove metodologias são comparadas juntamente com os métodos propostos e as técnicas já comumente usadas ou estudadas para sistemas elétricos. Os testes incluem sinais com ruídos, harmônicas, sub-harmônicas, variações de frequência em degrau, rampa e senoidal, variações de fase e tensão em degrau. Os testes ainda incluem um sinal provindo de simulação em que um bloco de carga é inserido e logo após retirado do sistema. Ao final é realizada uma comparação entre as técnicas, sendo possível identificar as vantagens e desvantagens de cada uma e, assim, indicar as melhores a serem usadas em sistemas elétricos de potência.
Lerm, Andre Arthur Perleberg. "Análise de bifurcações locais em sistemas elétricos de potência." Florianópolis, SC, 2000. http://repositorio.ufsc.br/xmlui/handle/123456789/79174.
Full textMade available in DSpace on 2012-10-18T00:06:14Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T18:02:52Z : No. of bitstreams: 1 170964.pdf: 3996205 bytes, checksum: 57ef03befbe88ec8a3a07c302dad9fb3 (MD5)
Este trabalho apresenta uma metodologia para a determinação de diagramas de bifurcação em sistemas elétricos de potência reais. Esta metodologia prevê a determinação dos pontos de equilíbrio de um sistema elétrico a partir do seu conjunto de equações algébrico-diferencial, em que os valores de referência dos reguladores automáticos de tensão e outros controladores sejam mantidos constantes ao longo de toda a análise efetuada. Este procedimento permite que as curvas potência/tensão obtidas sejam equivalentes aos diagramas de bifurcação da teoria de bifurcações, tornando a análise coerente com esta. A proposição de análise de sistemas reais, por outro lado, fundamenta-se no uso de uma modelagem realista dos componentes que possuem uma participação decisiva no processo de instabilidade de um sistema, tais como reguladores de tensão, limitadores de sobrecorrente de campo, limitadores de subcorrente de campo e compensadores de corrente reativa. A metodologia proposta é utilizada na simulação de dois sistemas elétricos. O primeiro, refere-se a um sistema hipotético de 3 barras, útil para a compreensão de alguns fenômenos relacionados ao processo de instabilidade de um sistema elétrico. O segundo sistema refere-se ao sistema sul brasileiro reduzido, com a representação de 213 barras e 20 geradores. Os geradores deste sistema possuem representação detalhada de RATs, ESPs, limitadores de tensão e corrente de campo, bem como limites de corrente de armadura. Os resultados obtidos e apresentados através de diversas figuras demonstram a importância da modelagem proposta no processo de identificação de margens de estabilidade realistas para um sistema elétrico.
Vargas, Germán Andrés López. "Análises de sistemas elétricos de potência com aerogeradores utilizando fluxo de potência ótimo." reponame:Repositório Institucional da UFABC, 2015.
Find full textDissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2015.
Este trabalho visa à operação ótima de um sistema de energia elétrica com a presença de aerogeradores. Considerando as injeções de potência ativa e reativa para a geração eólica, será analisado o comportamento da rede por meio de um Fluxo de Potência Ótimo Multiobjetivo (FPO - MO). A metodologia consiste na modelagem da rede elétrica, inserindo as características do gerador eólico na formulação do FPO - MO, objetivando minimizar as perdas ativas em conjunto com o perfil de tensão por meio do despacho ótimo de potência ativa e reativa. O problema modelado como um FPO - MO reativo é resolvido com auxilio do AMPL (Modeling Language for Mathematical Programming) e do solver Knitro. Estudos realizados com os sistemas IEEE de 14, 30, 57 e 118 barras evidenciam os benefícios da utilização da geração eólica aliada ao FPO - MO.
This approach aims optimal operation of power system with wind turbines. Considering the active and reactive power injections for wind generation, network behavior is analyzed using a multi-objective Optimal Power Flow (OPF - MO). The methodology consists in modeling the electrical network by entering characteristics of wind generator in the formulation of the FPO - MO, aiming to minimize active power losses in conjunction with the voltage profile through the optimal dispatch of active and reactive power. The problem modeled as a FPO - MO reactive is solved with the aid of AMPL (Modeling Language for Mathematical Programming) and Knitro solver. Studies with the IEEE 14, 30, 57 and 118 modified system show the benefits of using wind power combined with the FPO - MO.
Altran, Alessandra Bonato [UNESP]. "Sistema inteligente para previsão de carga multinodal em sistemas elétricos de potência." Universidade Estadual Paulista (UNESP), 2010. http://hdl.handle.net/11449/100304.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A previsão de carga, em sistemas de energia elétrica, constitui-se numa atividade de grande importância, tendo em vista que a maioria dos estudos realizados (fluxo de potência, despacho econômico, planejamento da expansão, compra e venda de energia, etc.) somente poderá ser efetivada se houver a disponibilidade de uma boa estimativa da carga a ser atendida. Deste modo, visando contribuir para que o planejamento e operação dos sistemas de energia elétrica ocorram de forma segura, confiável e econômica, foi desenvolvida uma metodologia para previsão de carga, a previsão multinodal, que pode ser entendida como um sistema inteligente que considera vários pontos da rede elétrica durante a realização da previsão. O sistema desenvolvido conta com o uso de uma rede neural artificial composta por vários módulos, sendo esta do tipo perceptron multicamadas, cujo treinamento é baseado no algoritmo retropropagação. Porém, foi realizada uma modificação na função de ativação da rede, em substituição à função usual, a função sigmoide, foram utilizadas as funções de base radial. Tal metodologia foi aplicada ao problema de previsão de cargas elétricas a curto-prazo (24 horas à frente)
Load forecasting in electric power systems is a very important activity due to several studies, e.g. power flow, economic dispatch, expansion planning, purchase and sale of energy that are extremely dependent on a good estimate of the load. Thus, contributing to a safe, reliable, economic and secure operation and planning this work is developed, which is an intelligent system for multinodal electric load forecasting considering several points of the network. The multinodal system is based on an artificial neural network composed of several modules. The neural network is a multilayer perceptron trained by backpropagation where the traditional sigmoide is substituted by radial basis functions. The methodology is applied to forecast loads 24 hours in advance
Altran, Alessandra Bonato. "Sistema inteligente para previsão de carga multinodal em sistemas elétricos de potência /." Ilha Solteira : [s.n.], 2010. http://hdl.handle.net/11449/100304.
Full textAbstract: Load forecasting in electric power systems is a very important activity due to several studies, e.g. power flow, economic dispatch, expansion planning, purchase and sale of energy that are extremely dependent on a good estimate of the load. Thus, contributing to a safe, reliable, economic and secure operation and planning this work is developed, which is an intelligent system for multinodal electric load forecasting considering several points of the network. The multinodal system is based on an artificial neural network composed of several modules. The neural network is a multilayer perceptron trained by backpropagation where the traditional sigmoide is substituted by radial basis functions. The methodology is applied to forecast loads 24 hours in advance
Orientador: Carlos Roberto. Minussi
Coorientador: Francisco Villarreal Alvarado
Banca: Anna Diva Plasencia Lotufo
Banca: Maria do Carmo Gomes da Silveira
Banca: Gelson da Cruz Junior
Banca: Edmárcio Antonio Belati
Doutor
Vianna, Marcelo Pinto. "Gerenciamento de potência reativa em sistemas de distribuição utilizando controlador fuzzy de fator de potência." Pontifícia Universidade Católica do Rio Grande do Sul, 2009. http://hdl.handle.net/10923/3217.
Full textThis dissertation tackles the management of reactive power in distribution systems using the concept of centralized control of power factor as a DMS (Distribution Management System) function. The methodology developed uses two fuzzy controllers in cascade with the purpose to coordinate the operation of capacitor banks and synchronous generators in the medium voltage distribution network. The aim is to ensure an adequate range of power factor and reactive power, using as control variables the power factor violation, the sensitivity of the equipment and the positions of control devices. The methodology was implemented in Matlab using the fuzzy logic toolbox. The voltage control is treated as a local controller and it is provide for voltage regulators and under load tap change transformer. Power factor violations, voltage levels and overloads are monitored for a power flow routine. The results and analysis of simulations of two distribution tests systems showed the effectiveness of the proposed model to maintain the operational limits within ranges suitable for both the electric utility and costumers.
Esta dissertação aborda o gerenciamento de potência reativa em sistemas de distribuição, utilizando o conceito de controle centralizado de fator de potência como uma função do DMS (Distribution Management System). A metodologia desenvolvida utiliza dois controladores fuzzy em cascata para coordenar a operação de bancos de capacitores e geradores síncronos existentes na rede de distribuição de média tensão, com o objetivo de assegurar uma faixa adequada de fator de potência e potência reativa, utilizando como variáveis de controle a violação do fator de potência, a sensibilidade dos equipamentos e a posição dos dispositivos de controle. A metodologia foi implementada no toolbox de lógica fuzzy do Matlab. O controle de tensão foi realizado de forma local pelos reguladores de tensão e pelo transformador com mudança de tap da subestação. As violações de fator de potência e os níveis de tensão e carregamento são verificados por uma rotina de fluxo de potência. São apresentados os resultados e análises das simulações de dois sistemas testes de distribuição que demonstraram a eficácia do modelo proposto para manter os limites operacionais dentro de faixas adequadas tanto para a concessionária de energia como para os consumidores.
Martin, Claudio. "Prognóstico de demanda de potência elétrica para planejamento e operação de sistemas elétricos." Florianópolis, SC, 2005. http://repositorio.ufsc.br/handle/123456789/101749.
Full textMade available in DSpace on 2013-07-15T23:06:39Z (GMT). No. of bitstreams: 1 224285.pdf: 2388221 bytes, checksum: c158e3cabf9161b337f2c705f9867968 (MD5)
O objeto da pesquisa é o estudo das técnicas utilizadas para o prognóstico de demandas de potência elétrica, apresentadas na forma de séries temporais, motivado pela necessidade de definir valores futuros com base em valores históricos, visando a utilização em estudos de planejamento de curto prazo de sistemas elétricos, utilizando a máquina de vetor de suporte como ferramenta de treinamento e prognóstico. A máquina de vetor de suporte desenvolvida nos anos 90, baseada na teoria estatística da aprendizagem se apresenta como uma máquina de aprendizagem universal, em que não é necessário determinar a priori o número de neurônios da camada de entrada, o qual é definido ao longo do processo. O projeto da máquina depende da extração de um subconjunto, dos dados de treinamento, que servirão como vetores suporte, representando uma característica estável do conjunto de dados de treinamento, evitando o excesso de ajuste da máquina de aprendizagem. A pesquisa efetuada apresenta as principais formulações existentes para regressão de séries temporais, focando sobre o desenvolvimento da máquina de vetor de suporte, apresentando um estudo de caso com série temporal de demanda de potência. Os resultados encontrados com a utilização da máquina de vetor de suporte são compatíveis com as necessidades do planejamento e operação de sistemas elétricos, apresentando erros de prognóstico menores, na ordem de 16,3% para os prognósticos dos perfis de demanda de meio de semana(terça a sexta-feira), e, de 37,3% para os prognósticos dos perfis de final de semana(sábado, domingo e segunda-feira), comparativamente com aqueles obtidos com a rede de função de base radial.
MELO, Natã Venâncio de. "Uma técnica de análise de causa raiz para Sistemas Elétricos de Potência." Universidade Federal de Campina Grande, 2015. http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/548.
Full textMade available in DSpace on 2018-05-01T14:10:40Z (GMT). No. of bitstreams: 1 NATÃ VENÂNCIO DE MELO - DISSERTAÇÃO PPGCC 2015..pdf: 1756988 bytes, checksum: 57d7a292fbbca336c632f27a98fe34bc (MD5) Previous issue date: 2015-08-19
Análise de causa raiz de ocorrências de falha é uma tarefa extremamente importante para a recomposição e estabilidade do Sistema Elétrico de Potência (SEP). Nos Centros de supervisão e Controle, os operadores têm o desafio de analisar centenas de alarmes e descobrir a causa raiz das falhas num período curto de tempo. Caso não sejam executadas ações emergenciais, pode ocorrer um efeito cascata na rede elétrica e, em última instância, prejuízos de diversas ordens. surge, portanto, a necessidade de soluções que automatizem a descoberta da causa raiz de falhas. este trabalho apresenta uma nova técnica de análise de causa raiz que oferece a geração de árvores de propagação de falha, adaptabilidade e mudanças topológicas, facilidade de adaptação a novos alarmes, tratamento à dessincronização de alarmes e meios fáceis de alertar as regras de negócio. ele se destaca pela simplicidade de implementação, que utiliza regras de causa e efeito entre os equipamentos, e pelo bom desempenho na geração de árvores de falha. Sua validação foi realizada por especialistas da área de operação de sistemas elétricos de potência, utilizando ocorrências de falhas reais decorrentes de grandes redes elétricas.
The root cause analysis of fault is an extremely task to keep the stability of the Eletric Power System (EPS). In the Supervision and Control Centers, the operators have the challenge of analyzing hundreds of alarms and discover the root cause of failures in a short period of time. If actions are not performed very quickly, the fault can spread and generate a ripple effect in the power grid. To help the operators, it becomes necessary to develop a solution to automate the discovery of root cause of faults. This work presents a new technique of root cause analysis of fault that offers the generation of trees of fault propagation, adaptability to topological changes, facility to change the business rules. It shows a simple implementation that use rules of cause and effect between the equipments and a good performance in generating fault trees. the new technique was validated by engineers of the area of eletric poert systems with fault occurrences of big power grids.
Padua, Junior Carlos Rezende de. "Modelos lineares de sistemas elétricos de potência: um estudo comparativo /." Ilha Solteira, 2014. http://hdl.handle.net/11449/111120.
Full textCo-orientador: Marcos Amorielle Furini
Banca: Maria Lúcia Martins Lopes
Banca: Ricardo Frangiosi de Moura
Resumo: Este trabalho apresenta estudos comparativos entre o Modelo de Sensibilidade de Potência, o Modelo de Sensibilidade de Corrente (proposta deste trabalho) e o Modelo de Heffron e Phillips, todos os três modelos no ambiente multimáquinas. O objetivo principal do trabalho é analisar o Modelo de Sensibilidade de Corrente e comparar quantitativamente e qualitativamente seus resultados com os obtidos pelo Modelo de Sensibilidade de Potência e Modelo de Heffron e Phillips. Estes modelos serão utilizados no estudo da estabilidade a pequenas perturbações de sistemas elétricos de potência. Os três modelos foram implementados computacionalmente utilizando-se o software Mat- Labr e foram realizadas simulações em quatro sistemas teste muito conhecidos na literatura. Os resultados obtidos permitiram concluir a respeito da utilização dos modelos e sua validade na análise da estabilidade a pequenas perturbações de sistemas elétricos de potência
Abstract: This paper presents comparative studies with the Power Sensitivity Model and the Current Sen- sitivity Model (which is a proposal of this work) and the Heffron and Phillips Model, all of them for multimachine systems. The main objective of this work is to analyze the Current Sen- sitivity model and compare quantitatively and qualitatively the results with those obtained with the Power Sensitivity Model and the Heffron and Phillips Model. These models will be used to study the small-signal stability of the electric power systems. The three models are computationally implemented using MATLAB software and simula- tions were executed for four test systems very known in the literature. The results obtained are important to validate the use in analyzing of the small-signal stability in electric power systems
Mestre
Sousa, Thales. "Estudo de planejamento de reativos em sistemas elétricos de potência." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-09082004-164410/.
Full textThe present dissertation proposes the development of a novel approach to the solution of reactive planning problem in electrical power systems. A bibliographical survey to show the different researches developed in this area was done. This study uses langrange multipliers obtained from the optimal power flow solution, through interior point method, to determine the buses where reactive power will be allocated. Starting from the determination of these buses, a linear programming problem is solved to quantify the reactive power to be allocated. Studies were carried ou for the proposed approach validation and verification in the systems Ward & Hale of 6 buses, system of 8 buses, systems IEEE of 30 and 118 buses.
Oliveira, Ricardo Vasques de. "Projeto de controladores de amortecimento para sistemas elétricos de potência." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-02072006-192756/.
Full textThe present work proposes, as innovation, an upper bound for the output energy of the closed loop system to be used as a performance index in the design of robust controllers to damp low-frequency electromechanical oscillations in electric power systems. The output of the closed loop system is specified so that the output energy corresponds to the accumulated value of the kinetic energy deviation of the closed loop system. The performance index used in the procedure has shown to be suitable to the oscillation problem. The proposed performance index is used in the formulation of a systematic design methodology. The control problem is structured in the form of linear matrix inequalities, allowing a numerical solution to the control problem. The adopted performance index is less costly in terms of computational effort when compared with the traditional minimum damping ratio (performance index usually accepted in power system as small signal stability margin) via regional pole placement in the LMI formulation. This characteristic may be significant to the computational time required for the controller design involving large power system models. The robust damping controller design, based on multimachine models without the infinite-bus assumption, constitutes the second part of this research proposal. The problems inherent to the infinte-bus assumption are solved by means of two approaches which do not use such assumption. The first proposed approach refers to the use of a multimachine model adopting one machine angle of the system as angular reference. The second adopted approach is the incorporation of the primary speed control in the multimachine model regarding to the first approach. Besides solving the problem regarding to the use of infinite-bus assumption, the present work also proposes analyses of such assumption influence in the design of damping controllers. The influence of such assumption, in the design of the controllers, is outlined by means of exposed fundamentals and results obtained with the proposed approaches
Padua, Junior Carlos Rezende de [UNESP]. "Modelos lineares de sistemas elétricos de potência: um estudo comparativo." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/111120.
Full textEste trabalho apresenta estudos comparativos entre o Modelo de Sensibilidade de Potência, o Modelo de Sensibilidade de Corrente (proposta deste trabalho) e o Modelo de Heffron e Phillips, todos os três modelos no ambiente multimáquinas. O objetivo principal do trabalho é analisar o Modelo de Sensibilidade de Corrente e comparar quantitativamente e qualitativamente seus resultados com os obtidos pelo Modelo de Sensibilidade de Potência e Modelo de Heffron e Phillips. Estes modelos serão utilizados no estudo da estabilidade a pequenas perturbações de sistemas elétricos de potência. Os três modelos foram implementados computacionalmente utilizando-se o software Mat- Labr e foram realizadas simulações em quatro sistemas teste muito conhecidos na literatura. Os resultados obtidos permitiram concluir a respeito da utilização dos modelos e sua validade na análise da estabilidade a pequenas perturbações de sistemas elétricos de potência
This paper presents comparative studies with the Power Sensitivity Model and the Current Sen- sitivity Model (which is a proposal of this work) and the Heffron and Phillips Model, all of them for multimachine systems. The main objective of this work is to analyze the Current Sen- sitivity model and compare quantitatively and qualitatively the results with those obtained with the Power Sensitivity Model and the Heffron and Phillips Model. These models will be used to study the small-signal stability of the electric power systems. The three models are computationally implemented using MATLAB software and simula- tions were executed for four test systems very known in the literature. The results obtained are important to validate the use in analyzing of the small-signal stability in electric power systems
Mustafa, Thair Ibrahim Abdel Hamid. "Contribuição ao estudo da proteção de sistemas elétricos de potência." Florianópolis, SC, 2004. http://repositorio.ufsc.br/xmlui/handle/123456789/86900.
Full textMade available in DSpace on 2012-10-21T11:53:11Z (GMT). No. of bitstreams: 1 204072.pdf: 4243559 bytes, checksum: 1bc87ff64847aaadbf6352bb0e858613 (MD5)
Araujo, Elaynne Xavier Souza. "Fluxo de potência ótimo em sistemas elétricos de potência através de um algoritmo genético multiobjetivo." Universidade Estadual Paulista (UNESP), 2018. http://hdl.handle.net/11449/153015.
Full textApproved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-03-14T12:06:56Z (GMT) No. of bitstreams: 1 araujo_exs_dr_ilha.pdf: 5331631 bytes, checksum: 60e1011da397d7e88cc9d80319169d76 (MD5)
Made available in DSpace on 2018-03-14T12:06:56Z (GMT). No. of bitstreams: 1 araujo_exs_dr_ilha.pdf: 5331631 bytes, checksum: 60e1011da397d7e88cc9d80319169d76 (MD5) Previous issue date: 2018-02-23
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Neste trabalho é proposto o desenvolvimento de uma ferramenta computacional para o planeja-mento e despacho ótimo de fontes de potência ativa, considerando as incertezas das cargas (le-ve, nominal e pesada) e fontes de energia renováveis não despacháveis através de uma aborda-gem probabilística. O modelo matemático é um problema de programação não linear inteiro misto, multiobjetivo, não convexo e probabilístico na sua forma original sem a necessidade de realizar qualquer tipo de simplificação ou linearização tanto das funções objetivo como das res-trições. Um algoritmo baseado na meta-heurística Non-dominated Sorting Genetic Algorithm (NSGA-II) é proposto para resolver o problema de maneira eficaz. Os resultados obtidos com as simulações realizadas usando a implementação computacional nos sistemas de testes IEEE30 barras e IEEE118 barras mostram a eficiência e robustez da metodologia proposta.
This work proposes the development of a computational tool for the planning and optimal dispatch of active power sources, considering the uncertainties of the loads (light, nominal and heavy) and non-dispatchable renewable energy sources through a probabilistic approach. The mathematical model is a multi-objective mixed-integer nonlinear programing problem, that is nonconvex and probabilistic in its original form, without the need to perform any kind of simplification or linearization of both objective functions and constraints. An algorithm based on the Non-dominated Sorting Genetic Algorithm (NSGA-II) meta-heuristic is pro-posed to solve the problem effectively. The results obtained with the simulations performed using the computational implementation in the IEEE30 bus and IEEE118 bus test systems show the efficiency and robustness of the proposed methodology.
167761/2014-5
Fraissat, Fernando Buzzo. "Estudo da teoria de potência conservativa para análise de sistemas elétricos /." Bauru : [s.n.], 2011. http://hdl.handle.net/11449/87175.
Full textBanca: Mario Oleskovicz
Banca: Flavio Alessandro Serrão Gonçalves
Resumo: A influência de distorções e assimetrias nos sistemas elétricos é um assunto quase tão antigo quanto o próprio sistema elétrico de corrente alternada. Importantes discussões datam do final do século XIX. Entretanto, com o crescimento contínuo do uso das chamadas cargas não-lineares, não só em atividades industriais e comerciais, mas também em aplicações residenciais, a presença de distorções nas formas de onde de corrente e/ou tensão tem provocado perturbações cada vez mais relevantes para o sistema elétrico. Somem-se a isto os efeitos do desbalanço de cargas ao longo dos sistemas polifásicos. Tem-se então uma situação que demanda uma revisão detealhada da metodologia de cálculo da potência e fator de potência nos sistemas elétricos atuais. Neste sentido, inúmeras teorias e definições de potência para circuitos com tensões e correntes distorcidas e/ou desequilibradas tem sido apresentadas, tanto no domínio da frequencia, quanto no domínio do tempo. No entanto, ainda existem muitas divergências em torno das várias metodologias apresentadas. A única certeza parece ser o fato de que a teoria convencional tem se mostrado incompatível com a realidade dos sistemas monofásicos e polifásicos atuais. Neste contexto, buscando contribuir com a discussão de novas propostas de teorias de potência, este trabalho apresenta uma breve revisão histórica de algum dos mais importantes métodos propostos na literatura, para o cálculo da potência elétrica sob condições ditas não ideais de transferência e consumo de energia. Além disso, o trabalho traz uma análise detalhada da aplicação da Teoria de Potência Conservativa (TPC), proposta recentemente por Tenti et. al. A teoria TPC foi analisada por meio de simulações computacionais de circuitos elétricos sob diversas condições de operação, bem como através do estudo de um caso experimental... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: The discussion about the influences of waveform distortions and asymmetries dates almost from the same period of the alternating current power system. However, considering the continuous increasing of non linear loads utilization, not only in industrial applications, but also in commercial and residential installations, such voltage and current distortions have lead to relevant power system's pertubation. In addition, assuming multiphase electrical circuits, the effects of load unbalaces lead to a novel situation, which demands a meticulous review of power and power factor calcultion methodologies. In this sense, numerous power theories have been proposed in order to deal with distorted and unbalanced voltage and current conditions, some in the frequency domain and some in the time domain. Nevertheless, there is not a convergence in terms of the specialists opinions. The only certainty seems to be the fact that the conventional theory should be revised, since it does not comply anymore with the modern power system's reality. In such context, this work tries to contribute to the discussion and undertanding of novel power theories. It starts with a concise review of some proposals found in literature and then, it presents a particular analysis of the Conservation Power Theory (CPT), proposed by Tenti et al. The CPT has been analyzed by means of the computational simulation of several different power circuits, as well as by means of experimental activities. The results indicate that such theory could be an interesting alterntive for the understanding of the physical phenomena related to multiphase and non linear power circuits
Mestre
Tortelli, Odilon Luís. "Alocação e operação de controladores FACTS em sistemas elétricos de potência." [s.n.], 2010. http://repositorio.unicamp.br/jspui/handle/REPOSIP/260631.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação
Made available in DSpace on 2018-08-17T09:21:57Z (GMT). No. of bitstreams: 1 Tortelli_OdilonLuis_D.pdf: 1186857 bytes, checksum: 5e13f6473425287a72e7c516fe18dc39 (MD5) Previous issue date: 2010
Resumo: Este trabalho apresenta um estudo relativo ao problema de alocação, operação e análise de desempenho de Controladores FACTS em Sistemas Elétricos de Potência. Nesse sentido são descritos os mais importantes Controladores FACTS em termos de suas características operativas e potencialidades e uma rotina computacional para cálculo de fluxo de potência, baseada no método de Newton-Raphson incluindo a representação dos diversos Controladores FACTS é apresentada. A abordagem de alocação e determinação ótima dos parâmetros de controle é vista de maneira desacoplada, sendo o problema de alocação tratado pela técnica de Algoritmos Genéticos e a otimização dos parâmetros dos controladores por meio do método do Gradiente Reduzido. É também proposta uma estratégia alternativa de alocação/operação baseada na funcionalidade dos diferentes controladores. Também neste trabalho, é apresentado o conceito de tracking de potência, que é estendido para permitir uma avaliação não convencional da interferência dos Controladores FACTS na redistribuição dos fluxos de potência. A fim de sumarizar os diversos aspectos associados a alocação, operação e análise de desempenho de Controladores FACTS, um estudo de caso é apresentado
Abstract: This thesis presents a study related to the problem of allocating, operating and analyzing the performance of FACTS Controllers in Electrical Power Systems. In this sense, the most important FACTS controllers are described in terms of their operational features and their potentialities and, also, a computational routine for calculating the power flow, based on the Newton-Raphson method and including the representation of several FACTS controllers, is developed. The allocation process and the optimal controllers adjustment are conducted in a decoupled approach based on expansion and operational planning aspects. Genetic Algorithms are employed in the allocation procedure and the controllers optimization is dealt by the classical Reduced Gradient technique. An alternative strategy for allocation/operation of the controllers is proposed, based on the functionality of the different FACTS devices. The concept of Power tracking is also presented and expanded in order to allow a non-conventional evaluation about the interference of the FACTS controllers in the redistribution of the power flows. To summarize the several aspects connected to the allocation, operation and performance of the FACTS controllers, a case study is presented
Doutorado
Energia Eletrica
Doutor em Engenharia Elétrica
Peres, Wesley. "Contribuições ao estudo de recomposição fluente de sistemas elétricos de potência." Universidade Federal de Juiz de Fora, 2012. https://repositorio.ufjf.br/jspui/handle/ufjf/1784.
Full textApproved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T13:30:59Z (GMT) No. of bitstreams: 1 wesleyperes.pdf: 1629298 bytes, checksum: 979f44672c05a9876154ebaff4efaf74 (MD5)
Made available in DSpace on 2016-07-13T13:30:59Z (GMT). No. of bitstreams: 1 wesleyperes.pdf: 1629298 bytes, checksum: 979f44672c05a9876154ebaff4efaf74 (MD5) Previous issue date: 2012-03-05
Este trabalho apresenta uma metodologia baseada em Fluxo de Potência Ótimo (FPO) e Análise de Sensibilidade para a definição da configuração mínima de rede necessária para garantir, com segurança, o processo de recomposição fluente de corredores radiais de transmissão. Nos instantes iniciais de recomposição, devido à baixa capacidade de geração que o sistema se encontra, uma estratégia importante consiste em elevar a Capacidade de Curto Circuito das barras. Neste sentido, a metodologia proposta baseia-se na incorporação, na função objetivo do FPO, da maximização da potência de curto circuito das barras. Para tanto, uma Análise de Sensibilidade é realizada a cada iteração do processo iterativo para determinar os fatores de ponderação de alocação associados à impedância equivalente permitindo a inclusão no FPO da maximização da potência de curto circuito das barras. Na metodologia proposta os reatores que mais reduzirem a impedância receberão menores fatores de ponderação de alocação. Adicionalmente, o FPO contempla a modelagem das máquinas síncronas, curva de capabilidade e o estudo de cada cenário de recomposição em regime permanente, pré e pós rejeição de carga. O programa desenvolvido em MATLAB é utilizado para a simulação de corredores de recomposição fluente do sistema elétrico brasileiro. Os resultados obtidos apontam para uma ferramenta eficaz ao estudo de recomposição fluente.
This work presents a methodology based on Optimal Power Flow (OPF) and Sensitivity Analysis to define a minimum network configuration for a power system fluent restoration taking security issues into account. At this early restoration stage, the system has low Short-Circuit Capacity due to the low generation capacity. An important strategy is to increase the Short Circuit Capacity at this operation stage through search network configurations with low bus equivalent impedance. In this work, the Short-Circuit Capacity is incorporated in the objective function of the OPF formulation by using sensitivity analysis which yields lowest allocation factors for more suitable reactors to reduce the equivalents impedances. The proposed OPF takes into account the synchronous machine model, the capability curves and the set of overvoltage critical restoration scenarios following load rejection. The restoration scenarios are represented at steady state prior and after load rejection. The computational tool is developed in the MATLAB platform and it is used to conduct case studies for fluent restoration branches of Brazilian Electric System. The results show that the proposed methodology is effective.
Ruback, Rodolfo Oliveira. "Análise de faltas em sistemas elétricos de potência considerando dados incertos." Universidade Federal de Juiz de Fora (UFJF), 2016. https://repositorio.ufjf.br/jspui/handle/ufjf/3657.
Full textApproved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-16T12:53:44Z (GMT) No. of bitstreams: 1 rodolfooliveiraruback.pdf: 2343401 bytes, checksum: 8f9848927e2f5b7628d4e279716725d4 (MD5)
Made available in DSpace on 2017-03-16T12:53:44Z (GMT). No. of bitstreams: 1 rodolfooliveiraruback.pdf: 2343401 bytes, checksum: 8f9848927e2f5b7628d4e279716725d4 (MD5) Previous issue date: 2016-08-02
A análise de faltas, também conhecida como análise de curto-circuito, é imprescindível tanto no âmbito de planejamento quanto na operação de um sistema elétrico de potência. Essa análise é geralmente realizada de forma determinística, para dados valores em um instante de tempo. Contudo, o sistema de potência é dinâmico e seus parâmetros estão sujeitos a variações. Desta forma, a utilização do modelo determinístico se torna inviável face as inúmeras simulações necessárias no sentido de representar todas as possíveis combinações das variações envolvidas no problema. Este trabalho propõe incorporar a matemática intervalar na análise de faltas, de modo a possibilitar a representação das incertezas dos parâmetros na forma de intervalos e, por conseguinte, gerar resultados intervalares de tensão e corrente na barra de falta, refletindo tais incertezas. Portanto, o objetivo básico é modelar e implementar um método para análise de faltas intervalar. Dois sistemas testes, um de 5 barras e outro de 14 barras, são utilizados para gerar as tensões e correntes intervalares no ponto de falta. Tais resultados são validados pela simulação de Monte Carlo.
Fault Analysis, also known as short-circuit analysis, is essential both in the planning and the operation of an electric power system. This analysis is usually done in a deterministic way for data values in an instant of time. However, the power system is dynamic and his parameters are subject to variations. Thus, using the deterministic model has become inaccurate face the numerous simulations required to represent all the combinations of possibles variations involved in the problem. This paper proposes to incorporate interval mathematics to fault analysis, in a way to represent the parameter uncertainties as intervals and therefore generate interval results of voltage and current in the short-circuited bar, reflecting these uncertainties. Therefore, the basic objective is to model and implement a method for interval fault analysis. Two test systems, one with 5 bars and the other with 14 bars, are used to generate voltages and currents interval in the fault point. These results are validated by Monte Carlo simulation.
Jorge, David Calhau. "Redes neurais artificiais aplicadas a proteção de sistemas elétricos de potência." Universidade de São Paulo, 1997. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-19012018-161622/.
Full textA distance relay for the protection of transmission lines is usually designed on the basis of fixed settings. The performance of such relays is therefore affected by the changing network parameters. The implementation of a pattern recognizer for power system diagnosis can provide great advances in the protection field. This work demonstrates the use of an Artificial Neural Network as a pattern classifier for a distance relay operation. The scheme utilizes the magnitudes of three phase voltage and current phasors, from one busbar of the transmission line, as inputs. An improved performance with the use of an Artificial Neural Networks approach is experienced once the relay can operate correctly, keeping the reach when faced with different fault conditions as well as network parameters change.
Silva, Raphael Philipe Mendes da. "Algoritmos genéticos aplicados à estimação fasorial em sistemas elétricos de potência." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-05102012-091637/.
Full textThis work presents the implementation and analysis of an intelligent technique, the genetic algorithm (GA), for the implementation of phasor measurement units (PMUs). The estimation of phasors in several spots in an electrical power system is important for the monitoring, control, protection and study of this system. However, these phasors must be in a common time reference in order to be usefull. This reference is achieved by using signals provided by the Global Positioning System (GPS) that synchronize the PMUs installed in the system. There are several techniques that can be used to estimate the phasors and local frequency using current and voltage wave signals. This project introduces the GAs as a phasor estimation tool applied to PMUs. Besides that, a version of the GA that demands less computational resources, the compact Genetic Algorithm is studied and implemented. A detailed study is performed using the international standard C37.118 as a guide comparing the GAs with two traditional techniques. The two traditional techniques are based on the DFT (Discrete Fourier transform) and a phaselocked loop filter (PLL). Synthetic and simulated data is used to evaluate the performance of the implemented algorithms. In order to take advantage of the parallel behavior of the genetic algorithms, a study of its implementation in FPGA (field programmable gate array) using the VHDL language is performed to make the genetic algorithms useful in real PMUs.
Yoshida, Everton Shigueaki. "Algoritmos para análise automática de faltas em sistemas elétricos de potência." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/3/3143/tde-29122014-175150/.
Full textThis work presents the development of algorithms for the automatic analysis of overcurrent events in electrical power systems. The algorithms proposed in this paper are based on data of voltages and currents recorded by intelligent electronic devices (digital oscillographs and / or protection relays) installed in electrical networks, which can evaluate the operating state of these networks based on this information. The algorithms incorporate an automatic system for overcurrent analysis, which is able to estimate the time of occurrence of the event, identify the steps involved and classify the fault type using the phasors of voltages and currents calculated from their records. Furthermore, this work presents a comparison between two distinct techniques for phasor calculation (the first one uses the Discrete Fourier Transform, with a cycle window, and the second one is based on genetic algorithms) and three distinct techniques to estimate the time of the occurrence of the event (the first is based on Fourier Transform and a digital filter that implements a probability density function, the second one replaces Fourier transform by Genetic Algorithm and the third one is based on Park transform). For the evaluation of the developed algorithms, cases from two distribution network model have been generated in the ATP software - Alternative Electromagnetic Transients Program, additionally, actual data from distribution Brazilian utilities systems were also analyzed by the developed algorithm.
Canola, Saulo Ricardo. "Alocação de unidades de geração termoelétrica em sistemas elétricos de potência." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-26022016-144332/.
Full textThe aim of this paper is to present a study of thermoelectrical generation allocation in electric power systems. The optimal power flow (OPF) was used to evaluate the optimal operation point for the power system and also Lagrange multipliers associated with the constraints. The Lagrange multipliers are the sensitivity between the objective function and its constraints. This sensitivity is used to verify in a power system where is the best place to incentive the allocation of new thermoelectrical power plants. Tests on the systems: 5 buses, IEEE 14 buses, IEEE 30 buses, equivalent CESP 440kV 53 buses and IEEE 118 buses showed the efficiency of the presented approach. This method of analyzing the system can be used in study of expansion planning system.
PESOTI, Paulo Murinelli. "Recomposição de Sistemas Elétricos de Potência com Auxílio de Função Energia." reponame:Repositório Institucional da UNIFEI, 2013. http://repositorio.unifei.edu.br:8080/xmlui/handle/123456789/775.
Full textMade available in DSpace on 2017-05-23T12:57:52Z (GMT). No. of bitstreams: 1 dissertacao_pesoti_2013.pdf: 8285943 bytes, checksum: 3bc7f40fb62340babfdc73e6627fc390 (MD5) Previous issue date: 2013-12
Após um blecaute, o processo de recomposição de sistemas elétricos entra em ação. É um processo extremamente complexo, podendo levar várias horas. Geralmente, o processo de recomposição segue alguns passos predefinidos. No caso do sistema brasileiro, algumas unidades geradores com capacidade de "black-star" iniciam o processo energizando pequenas ilhas geolétricas e reconectando algumas cargas prioritárias, Logo após, as ilhas são interconcetadas. Ocorrências têm mostrado dificuldades do Operador Nacional do Sistema (ONS) durante a coordenação e execução do processo. Uma abordagem baseada em função energia é apresentada como uma ferramenta que pode ajudar a tomada de decisão durante este processo. Inicialmente, a ferramenta é apresentada e aplicada em um sistema teste do IEEE. Em seguida, a ferramenta é aplicada em um caso real do sistema brasileiro. Simulações estáticas e dinâmicas são executadas para mostrar sua eficiência e robustez.
Fraissat, Fernando Buzzo [UNESP]. "Estudo da teoria de potência conservativa para análise de sistemas elétricos." Universidade Estadual Paulista (UNESP), 2011. http://hdl.handle.net/11449/87175.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
A influência de distorções e assimetrias nos sistemas elétricos é um assunto quase tão antigo quanto o próprio sistema elétrico de corrente alternada. Importantes discussões datam do final do século XIX. Entretanto, com o crescimento contínuo do uso das chamadas cargas não-lineares, não só em atividades industriais e comerciais, mas também em aplicações residenciais, a presença de distorções nas formas de onde de corrente e/ou tensão tem provocado perturbações cada vez mais relevantes para o sistema elétrico. Somem-se a isto os efeitos do desbalanço de cargas ao longo dos sistemas polifásicos. Tem-se então uma situação que demanda uma revisão detealhada da metodologia de cálculo da potência e fator de potência nos sistemas elétricos atuais. Neste sentido, inúmeras teorias e definições de potência para circuitos com tensões e correntes distorcidas e/ou desequilibradas tem sido apresentadas, tanto no domínio da frequencia, quanto no domínio do tempo. No entanto, ainda existem muitas divergências em torno das várias metodologias apresentadas. A única certeza parece ser o fato de que a teoria convencional tem se mostrado incompatível com a realidade dos sistemas monofásicos e polifásicos atuais. Neste contexto, buscando contribuir com a discussão de novas propostas de teorias de potência, este trabalho apresenta uma breve revisão histórica de algum dos mais importantes métodos propostos na literatura, para o cálculo da potência elétrica sob condições ditas não ideais de transferência e consumo de energia. Além disso, o trabalho traz uma análise detalhada da aplicação da Teoria de Potência Conservativa (TPC), proposta recentemente por Tenti et. al. A teoria TPC foi analisada por meio de simulações computacionais de circuitos elétricos sob diversas condições de operação, bem como através do estudo de um caso experimental...
The discussion about the influences of waveform distortions and asymmetries dates almost from the same period of the alternating current power system. However, considering the continuous increasing of non linear loads utilization, not only in industrial applications, but also in commercial and residential installations, such voltage and current distortions have lead to relevant power system's pertubation. In addition, assuming multiphase electrical circuits, the effects of load unbalaces lead to a novel situation, which demands a meticulous review of power and power factor calcultion methodologies. In this sense, numerous power theories have been proposed in order to deal with distorted and unbalanced voltage and current conditions, some in the frequency domain and some in the time domain. Nevertheless, there is not a convergence in terms of the specialists opinions. The only certainty seems to be the fact that the conventional theory should be revised, since it does not comply anymore with the modern power system's reality. In such context, this work tries to contribute to the discussion and undertanding of novel power theories. It starts with a concise review of some proposals found in literature and then, it presents a particular analysis of the Conservation Power Theory (CPT), proposed by Tenti et al. The CPT has been analyzed by means of the computational simulation of several different power circuits, as well as by means of experimental activities. The results indicate that such theory could be an interesting alterntive for the understanding of the physical phenomena related to multiphase and non linear power circuits
Andrade, Sonia Ribeiro Campos. "Sistemas de medição fasorial sincronizada:: aplicações para melhoria da operação de sistemas elétricos de potência." Universidade Federal de Minas Gerais, 2008. http://hdl.handle.net/1843/BUOS-8D3FHK.
Full textA presente dissertação de mestrado investiga as aplicações dos Sistemas de Medição Fasorial Sincronizada na monitoração e no controle dos Sistemas Elétricos de Potência. Esta tecnologia de medição pode trazer ganhos extremamente significativos para a operação dos sistemas elétricos. Entretanto, por ser ainda recente, constitui campo aberto a investigações, principalmente no que diz respeito ao uso dos fasores sincronizados. Visando contribuir nesta direção, este trabalho apresenta um texto estruturado de forma a se tornar uma referência para aqueles que se iniciam no tema. São discutidas as aplicações já registradas na literatura, identificando os fundamentos teóricos nos quais estas se sustentam, e são apresentadas propostas para viabilizar a implementação de sistemas fasoriais nas empresas. Exemplos de aplicação das propostas são incluídos no trabalho.
Milanezi, Junior Jayme. "Predição espacial temporal de sistemas elétricos de potência incluindo fontes renováveis emergentes." reponame:Repositório Institucional da UnB, 2014. http://repositorio.unb.br/handle/10482/16515.
Full textSubmitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-10-15T18:54:01Z No. of bitstreams: 1 2014_JaymeMilaneziJunior.pdf: 6506741 bytes, checksum: 35af0d3d19c8dcffb7174539404b393b (MD5)
Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2014-10-16T17:36:58Z (GMT) No. of bitstreams: 1 2014_JaymeMilaneziJunior.pdf: 6506741 bytes, checksum: 35af0d3d19c8dcffb7174539404b393b (MD5)
Made available in DSpace on 2014-10-16T17:36:58Z (GMT). No. of bitstreams: 1 2014_JaymeMilaneziJunior.pdf: 6506741 bytes, checksum: 35af0d3d19c8dcffb7174539404b393b (MD5)
A atividade de planejamento de sistemas de potência inclui, como um de seus maiores desafios, a predicação do comportamento da carga. Com a finalidade de otimizar oinvestimento ante os dados de consumo, as empresas do setor elétrico lançam mão de várias técnicas de previsão da evolução da demanda que devem atender. No presente trabalho, o tema da predição espacial e temporal da carga é enfrentado, estudando e incorporando, simultaneamente, a tendência hoje já observada de inclusão de fonte sem microgeração distribuída. Três fontes renováveis e emergentes de geração foram consideradas como geradoras de energia pelos consumidores: enguias elétricas, painéis fotovoltaicos para aproveitamento da luz solar e de interiores, e antenas para reciclagemda energia existente nas ondas eletromagnéticas de radiodifusão. Quatro métodos preditivos foram empregados para prever o comportamento da carga: modelo Auto-Regressivo (AR), Auto-Regressivo com Variável eXógena (ARX), Auto-Regressivo deMédia Móvel com Variável eXógena (ARMAX) e Redes Neurais Artificiais (ANN). Os dados de consumo foram as máximas demandas semanais registradas em 8 Subestações da cidade de Leipzig (Saxônia, Alemanha), durante os anos de 2001, 2002, 2003 e 2004.O dado exôgeno considerado foi a temperatura, em valores diretos e logarítmicos. Das 209 semanas existentes entre 2001 e 2004, as 200 primeiras destinaram-se ao ajuste dos coeficientes nos modelos AR e ao treinamento da rede neural; as 9 semanas restantesforam destinadas à comparação de resultados. A aplicação das técnicas deu-se, assim,em dois estágios: no primeiro, os dados reais da rede de Leipzig foram considerados, eno segundo estágio trabalhou-se com novos valores de demandas máximas, originadaspela inserção de valores hipotéticos de energia recebida das três fontes citadas. Emambos os estágios, o modelo ARMAX foi o de melhor precisão na previsão de dados.O sistema de redes neurais demonstrou ser um sistema sub-ótimo de previsão. ______________________________________________________________________________ ABSTRACT
Power systems planning activities include load behavior prediction as one of its mostchallenging tasks. In order to optmize investments related to consumption data, utilitiesfrom the Electrical Sector resort to several forecasting techniques so that theycan predict the power demand which these utilities must support. Along the presentwork, issues related to the spatial and temporal predictions are faced, considering,simultaneously, the observed trend of microgeneration spread. Three emergent renewablesources were proposed to be taken on by consumers: electric eels, photovoltaicsolar panels for outdoor generation and indoor light energy harvesting, and antennasfor radio frequency energy recycling. Four predictive methods were employed in orderto forecast load evolution: Auto-Regressive (AR), Auto-Regressive with eXogeneousinputs (ARX), Auto-Regressive Moving Average with eXogeneous inputs (ARMAX)models and Artificial Neural Networks (ANN). Consumption data were the maximumweekly power demands registered over 8 Power Substations from the city of Leipzig(Saxony, Germany), during the years 2001, 2002, 2003 and 2004. The exogeneousvariable adopted was temperature, in realistic and in logarithmic values. During the209 weeks which are comprised between 2001 and 2004, the _rst 200 weeks served tocoe_cients adjustments, with regards to AR models, and the trainning of the neuralnetwork, in the case of ANN. The last 9 weeks were destinated for results comparison.Techniques were undertaken in two stages: _rstly, only realistic data from LeipzigSubstations were considered, and in the second stage, new values for maximum powerdemands were obtained by means of simulations upon the three emergent sources. Inboth stages, ARMAX model returned the _ttest results, whereas ANN characterizeditself as a sub-optimal prediction system.
Brito, Hélio Glauco Ferreira. "Técnicas de filtragem digital aplicadas à proteção de sistemas elétricos de potência." Universidade de São Paulo, 1996. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-04012018-173957/.
Full textThis work introduces an analysis and a comparative study of some of the techniques for digital filtering of the voltage and current waveforms from faulted transmission lines. This study is of fundamental importance for the development of algorithms applied to digital protection of electric power systems. The techniques studied are based on the Discret Fourier Transform theory, the Walsh functions and the Kalman filter theory. Two aspects were emphasised in this study: Firstly, the non-recursive techniques were analysed, with the implementation of filters based on the Fourier theory and the Walsh functions. Secondly, recursive techniques were analysed, with the implementation of the filters based on the Kalman theory and once more on the Fourier theory.
Zeferino, Cristiane Lionço. "Avaliação e controle de margem de carregamento em sistemas elétricos de potência." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-05052011-091651/.
Full textThis work proposes the determination of the Maximum Loading Point (MLP) in electric power system via Lagrangian Modified Barrier Function (LMBF) method, a variant of Interior Point (IP). The LMBF method is also used to determine which bus, for each system, has the highest sensitivity of load factor, i.e., which bus would be the first to have load shedding in order to increase the loading margin system and thus prevent voltage collapse. To validate this approach, the Sensitivity Analysis (SA) technique was used for the confirmation of the results obtained by the LMBF method. The formulation of the problem considered the equations of power balance of the electrical system equality constraints, and the buses voltage magnitude limits, as well as the limits of reactive power control at the buses of that power inequality constraints. Case studies were conducted in a system of 3 buses and IEEE systems 14, 57, 118 and 300 buses, demonstrating the robustness and efficiency of the proposed algorithms.
Barbosa, Daniel. "Estimação da freqüência em sistemas elétricos de potência através de filtragem adaptativa." Universidade de São Paulo, 2007. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-11092007-155259/.
Full textThis work presents a method for frequency estimation in power systems using adaptive filters based in the algorithm of least mean square (LMS). The analysis of the power system is made through the conversion of the three-phase voltages in a complex signal with the application of \'alfa\'\'beta\' transform, whose complex form was directed to the algorithm of adaptive filtering. The method is based on the application of the adaptive filtering for tracking the input signal, and it allows verifying its variant behavior in time. The algorithm was tested through waveforms generated by Matlab software and simulations carried out through Alternative Transients Program (ATP) software. It is important to point out that in the simulations using ATP many diferent power system equipments had been modeled, including a synchronous generator with speed regulation, transmission lines with variation in frequency and power transformers with their saturation curves. The objective of these tests was to generate data for diverse and distinct situations for the verification and the analysis of the proposed methodology. The results of the research show the excellence in the applicability of the algorithm considered in frequency estimation of an electrical system, even with noisy signals, as well as the tracking of the frequency during operation. Some of the results are compared to the ones presented by a commercial relay set to track frequency.
Siqueira, Daniel Souto. "Controle não linear aplicado a dispositivos FACTS em sistemas elétricos de potência." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-20062012-152858/.
Full textThe TCSC is one of the most effective dynamic compensators used in electric power systems, offering a flexible adjustment, quickly and reliably, enabling the application of advanced theories in their control. These devices can play important roles for the operation and control of the networks, bringing many benefits. Because of the beneficial use of these devices a large amount of work has been developed in order to synthesize their control laws. However most of these studies are based on the classical control techniques, designing control laws based on linearized systems at specific operating points. However, these techniques do not guarantee that system disturbances which lead to operating points far away from those used for the controller design, the performance of the controller will be effective contributing to the system stabilization. Aiming to further studies and understanding of the physical phenomena occurring in the real world systems, nonlinear models have being employed in the controller design and techniques based on these methodologies have been proposed as never. In this work the technique of nonlinear control based on the Generalized Control Energy Function, for synthesis of control laws, which stabilize the TCSC devices considering the losses in the system transmission lines are employed. These techniques were recently developed by SILVA et al. (2009), and they extend the ideas of Control Lyapunov Function for a larger class of problems. Besides allowing the controller design, the technique provides estimates of the system stability region and therefore can support the systematic evaluation of the contribution to the transient stability controller.
PESTANA, Marcelo Martinho. "Recomposição de Sistemas Elétricos de Potência e ferramentas de apoio à recomposição." reponame:Repositório Institucional da UNIFEI, 2009. http://repositorio.unifei.edu.br/xmlui/handle/123456789/1555.
Full textMade available in DSpace on 2018-08-17T18:40:48Z (GMT). No. of bitstreams: 1 dissertacao_0035948.pdf: 5195528 bytes, checksum: 448ef08eeaaa3c2d1e2845e203f1e87a (MD5) Previous issue date: 2009-12
Esta dissertação descreve os aspectos relacionados a recomposição de sistemas elétricos de potência, principalmente no caso brasileiro, que é bastante singular devido à extensão do mesmo e forte predominância hidroelétrica. Descreve o processo de recomposição de sistema elétrico brasileiro na atualidade e como é realizado o treinamento dos operadores de sistema do Centro Regional de Operação Sudeste (COSR-SE) do Operador Nacional do Sistema Elétrico (ONS). Este trabalho possui, como primeiro subproduto, uma ferramenta computacional proposta para treinamento destes profissionais. Outro aspecto importante focado neste trabalho é a necessidade dos operadores de sistemas terem como ferramentas computacionais de apoio à atividade de recomposição de sistemas elétricos sob sua responsabilidade. Para atender esta necessidade, este trabalho tem como segundo subproduto, a proposição de uma ferramenta computacional, que tem como objetivo apoiar a equipe de tempo real do COSR-SE na recomposição do sistema elétrico em sua área de atuação.
Santos, André Katayama dos. "Metodologia inteligente para o diagnóstico de alarmes em sistemas elétricos de potência." reponame:Repositório Institucional da UFPR, 2013. http://hdl.handle.net/1884/28993.
Full textDurce, Carolina Corrêa. "Normalização complexa e cálculo de fluxo de potência para sistemas elétricos emergentes." reponame:Repositório Institucional da UFPR, 2013. http://hdl.handle.net/1884/29271.
Full textSilva, Josimar Oliveira. "Controle de emergência em sistemas elétricos de potência com rejeição de carga." reponame:Repositório Institucional da UFSC, 1992. https://repositorio.ufsc.br/handle/123456789/111706.
Full textSENA, José Adolfo da Silva. "Desenvolvimento de framework para análise e simulação dinâmica de sistemas elétricos de potência." Universidade Federal do Pará, 2013. http://repositorio.ufpa.br/jspui/handle/2011/3799.
Full textApproved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-05-06T13:57:42Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_DesenvolvimentoFrameworkAnalise.pdf: 4581009 bytes, checksum: 6edb3a474cd7c7d7f271c175bbd47f06 (MD5)
Made available in DSpace on 2013-05-06T13:57:42Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_DesenvolvimentoFrameworkAnalise.pdf: 4581009 bytes, checksum: 6edb3a474cd7c7d7f271c175bbd47f06 (MD5) Previous issue date: 2013
Esta tese apresenta uma metodologia flexível orientada a objetos (OO) para a aplicação no projeto e implementação de sistemas de software utilizados na realização de estudos dinâmicos de sistemas elétricos de grande porte. A metodologia OO proposta objetiva tornar mais simples o desenvolvimento, a atualização e a manutenção de complexos sistemas de software para estudos de transitórios eletromecânicos em sistemas elétricos de potência. Os requisitos de usuário são mapeados para um conjunto de classes básicas, as quais são usadas para efetuar a modelagem de dispositivos dinâmicos tais como geradores elétricos. Para avaliação da metodologia foram realizados dois estudos de casos. No primeiro estudo caso o Framework foi aplicado na simulação das unidades geradoras da Usina Hidrelétrica de Tucuruí. Os resultados da simulação foram comparados com medições obtidos em ensaios no campo e mostrou a boa performance do Framework na reprodução dos fenômenos eletromecânicos desta usina de grande porte. No segundo estudo de caso, por outro lado, o Framework foi aplicado na modelagem de um sistema de geração fotovoltaico (PV) com seu sistema de Rastreamento da Potência Máxima (MPPT). O controle MPPT foi implementado usando técnicas digitais. Os resultados das simulações demonstram a performance do Framework na modelagem do sistema de controle de corrente, assim como no controle MPPT, dos sistemas de geração PV.
This thesis presents a flexible Object Oriented (OO) methodology for the design and implementation of simulation software system used to perform dynamic studies of large electrical power systems. The proposed OO methodology aims at make easier the development, upgrade and maintenance of complex software systems. The user's requirements are mapped to set base classes which are atomic classes to perform the modeling of the dynamic devices such as electrical generators. In order to evaluate the methodology, a simulation software system was developed using the OO modeling. In order to evaluate the Framework performance, two study cases were carried out. The first one apply the Framework on the modeling and simulation of generation units at Tucuruí Power Plant. The simulation results were comparated to data measurements from field tests and shown the good performance of the Framework on reproducing electromechanical phenomena of this large Power Plant. In the second study, by its turn, the Framework was applied to the modeling of a Photovoltaic (PV) generation system, along with its Maximum Power Tracking (MPPT). The MPPT control was implemented using digital techniques. The simulation results show the good performance of the Framework on modeling the current as well as MPPT control of PV generations systems.
Rosa, William Moreti da. "Ferramenta para análise estática em sistemas elétricos de potência com uso de sensibilidade." reponame:Repositório Institucional da UFABC, 2014.
Find full textToledo, Siles Paulino de. "Representação de conhecimentos e sistemas especialistas aplicados a sistemas de potência." Instituto Tecnológico de Aeronáutica, 1996. http://www.bd.bibl.ita.br/tde_busca/arquivo.php?codArquivo=1645.
Full textOstermann, Roberto. "Desenvolvimento de um sistema de gerenciamento de transformadores de potência instalados no sistema de transmissão da Companhia Estadual de Energia Elétrica." Pontifícia Universidade Católica do Rio Grande do Sul, 2006. http://hdl.handle.net/10923/3201.
Full textThis dissertation describes the conception, the implantation of the results reached in the development of "SGTF - CEEE / ATTN" - System of Administration of Power Transformers, that was implanted in the Area of Transmission of CEEE. It has as reference the experience of the energy company as well as a bibliographical revision of the methodologies and techniques regarding the theme. It begins with an approach on the evolution of the industrial engineering maintenance in Brazil, drawing a parallel one what happened in the evolution of the maintenance of transformers in the Brazilian electric system, it goes by a revision in the concepts of power transformers, degradation of the insulating system, identification of emissions through analysis of the gases dissolved in the oil and aging of the insulating paper. The base concepts of the Administration of Power Transformers are demonstrated through the details of the structures and resources of the "Modules" or available "Tools" in the system: Modules of Register, Maintenance, Evaluation of the Useful Life and Monitoring. The results and benefits reached with the implantation of the system of administration of transformers are presented as well as the advantages in applying the same ideas to the other equipments or facilities of the energy company.
Esta dissertação descreve a concepção, a implantação e os resultados alcançados no desenvolvimento do "SGTF - CEEE / AT", Sistema de Gerenciamento de Transformadores de Potência, implantado na Área de Transmissão da CEEE. Tem como referência a experiência da concessionária assim como uma revisão bibliográfica das metodologias e técnicas referente ao tema. Inicia com uma abordagem sobre a evolução da engenharia de manutenção industrial no Brasil, traçando um paralelo com o que ocorreu na manutenção de transformadores no sistema elétrico brasileiro, passa por uma revisão nos conceitos de transformadores de potência, degradação do sistema isolante, identificação de falhas através de análise dos gases dissolvidos no óleo e envelhecimento do papel isolante. Os fundamentos do Gerenciamento de Transformadores de Potência são demonstrados através do detalhamento das estruturas e recursos dos "Módulos" ou "Ferramentas" disponíveis no sistema: Módulos de Cadastro, Manutenção, Avaliação da Vida Útil e Monitoramento. São apresentados os resultados e benefícios alcançados com a implantação do sistema de gerenciamento de transformadores bem como as vantagens em estender os mesmos princípios a outros equipamentos ou instalações da concessionária.
Mijolaro, Ana Paula. "Sincronização de uma classe de sistemas não-lineares acoplados com aplicações em sistemas elétricos de potência." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-15102008-134152/.
Full textSynchronization of a class of coupled non-linear systems is studied in this work. From the theoretical point of view, we present synchronization results that provide sufficient conditions on the vector field and estimates of the coupling parameters that guarantee synchronization. Differently from the existing approaches in the nonlinear systems literature, our results can be applied to demonstrate synchronization in systems that do not have global attractors, including even unstable cases, where the solutions are unbounded. When the system does not globally synchronize, a result that provides uniform estimates of attractors is used to present an estimate of a positively invariant set contained in the synchronization region. The theoretical results are applied to demonstrate synchronization between two nonlinear pendulums and two coupled Duffing\'s systems. From the applied point of view, we study the problem of coherency between generators in electrical power systems. Using the theoretical results of this thesis, an index is proposed to detect and identify groups of weakly-coherent generators, the so called clusters. The proposed coherency analysis methodology proposed in this text does not require a great computational effort and is suitable for online applications. Our results have shown that this index analysis provides important information about the strong coupling between the generators, the location of the controlling unstable equilibrium points and the existence of combined unstable modes.
Silva, Mauricio Chinarelli Alves. "Análise de sistemas elétricos de potência com alocação de compensadores estáticos de reativos utilizando fluxo de potência ótimo." reponame:Repositório Institucional da UFABC, 2015.
Find full textDissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2014.
Esse trabalho apresenta uma análise da introdução de controladores FACTS no sistema elétrico através do fluxo de potência ótimo. O fluxo de potência ótimo foi modelado utilizando as ferramentas AMPL e o solver Knitro. Nos estudos feitos buscouse determinar a quantidade de reativos e também o ponto ótimo de instalação desses dispositivos. Para realizar a análise, os estudos foram feitos em três cenários de carga diferentes e com três funções objetivos diferentes. Com análises feitas nos sistemas IEEE 14 e 118 barras, foi possível notar uma melhora no sistema quando temos os controladores FACTS conectados. Observou-se que o ponto ideal de instalação de fonte de reativos depende da função objetivo e da carga do sistema. Com isso, demonstra-se que a introdução desse tipo de dispositivo pode aumentar a capacidade do sistema elétrico, suprindo o aumento da demanda de potência reativa.
This study presents an analysis of the introduction of different FACTS controllers in the electrical system by optimal power flow. For the analysis we used an optimal power flow in the system using the tools AMPL and solver Knitro. In studies of the electrical system were made seeking not only determine the amount of reactive, but also determine the optimum installation location of these devices. To perform the analysis studies were performed in three different load scenarios and with three different objectives functions. With analyzes the IEEE systems 14 and 118 bars, it was possible to notice an improvement in the system when we have the FACTS controllers connected. It was observed that the ideal location of reactive depends of the objective function and system load. Thus it is shown that the introduction of this type of device can be made to meet the increased demand of reactive power.
Piereti, Saulo Augusto Ribeiro. "Estimação de estado em sistemas elétricos de potência: composição de erros de medidas." Universidade de São Paulo, 2011. http://www.teses.usp.br/teses/disponiveis/18/18154/tde-13092011-160307/.
Full textBretas et al. (2009) has proved, using geometric background, that the measurement error can be decomposed into two components the detectable and the undetectable component respectively. Bretas has also demonstrated that the current methodologies used for processing of gross errors (GE), consider only the detectable component of the error. Thus, depending on the magnitude of the undetectable error components, such methods may fail. Given the above explanation, in this work a new methodology for processing the measurements with GE is proposed. This proposition is obtained by decomposing each measurement error into two components: the first, orthogonal to the Jacobian range space, whose magnitude is equal to the measurement residual and the other contained in that space, which does not contribute to the measurement residual. The ratio between the norms of those components was proposed as the measurement Innovation Index (II) which provides the new information a measurement contains regarding the other measurements. Using the II, a threshold value (TV) for each measurement is computed so that one can declare a measurement suspicious of having a GE. Then a filtering index (FI) is proposed to filter up, from the suspicious measurements, the one that has more chances of containing a GE. The IEEE-14 bus system, IEEE-30 bus system, and reduced 45-bus power system of south of Brazil, will be used to demonstrate the accuracy and efficiency of the proposed methodology. Tests conducted with the above systems were: i) The level test for GE detection, which consists in finding the minimum GE value in order it can be detected using the measurement TV; ii) The test where GE of 10 standard deviations is added to each measurement, once at a time, and using the measurement FI to identify which measurement has the error ant the using the composed measurement error (CNE) to correct measurement value; iii) The GE simple test.
Oliveira, Ricardo Vasques de. "Análise da coordenação entre estabilizadores clássicos e robustos em sistemas elétricos de potência." Universidade de São Paulo, 2003. http://www.teses.usp.br/teses/disponiveis/18/18133/tde-01032016-113918/.
Full textThis work presents an analysis carried out in electric power systems equipped with damping controllers designed by different methodologies. Three types of damping controllers were used. One of them is designed using the classical methodology (usually known as PSS, or power system stabilizer) and the other ones are designed using robust control techniques, and are called robust stabilizer in this text. One of the methodologies for the design of robust stabilizers uses the Heffron-Phillips model and the other utilizes the Multimachine model. Both robust stabilizers are based on a polytopic model that allows the modeling of uncertainties in the system through a convex set, where each vertex of the set represents a typical operating point of the system. The technique of dynamic output feedback associated to the regional pole placement is used to ensure that the robust stabilizers meet the practical requirements of the problem. The text presents an overview of power system modeling, as well as the problem of small signal stability. A detailed explanation of the proposed control schemes and the design procedures used is also presented. The results, obtained through nonlinear simulations and modal analysis of the closed loop system, show that stabilizers designed by different methodologies, operating simultaneously in a system, not always achieve a good performance. However, such performance is directly associated to the control technique used, to the system model adopted and to the application of coordination techniques.
SILVA, Saulo Ribeiro. "Planejamento Hidrotérmico Considerando a Penetração de Geração Eólica em Sistemas Elétricos de Potência." reponame:Repositório Institucional da UNIFEI, 2014. http://repositorio.unifei.edu.br:8080/xmlui/handle/123456789/352.
Full textMade available in DSpace on 2016-02-23T13:14:03Z (GMT). No. of bitstreams: 1 dissertacao_silva3_2014.pdf: 3331419 bytes, checksum: 3fc505bd6725949555106d65237a95ff (MD5) Previous issue date: 2014-05
Esta dissertação trata do problema de planejamento hidrotérmico do sistema elétrico brasileiro levando em consideração a penetração de geração eólica. Em um problema de planejamento hidrotérmico deseja-se minimizar os custos de produção de eletricidade buscando atender a demanda de energia elétrica do sistema considerando a operação de ambos: hidrelétricas e termelétricas. Atualmente, o modelo brasileiro de planejamento da operação não representa a geração eólica de maneira adequada dentro da modelagem matemática, sendo o montante de geração proveniente dessa fonte apenas descontado da demanda total de energia do sistema. Com o recente crescimento e evolução da energia eólica ao redor do mundo, torna-se necessário buscar soluções para um melhor planejamento dos sistemas elétricos. O Brasil possui um enorme potencial eólico, concentrado principalmente ao longo de sua costa atlântica e relativamente próximo aos grandes centros, o que torna esta opção ainda mais atraente. A geração de energia elétrica por meio de turbinas eólicas constitui uma alternativa para diversos níveis de demanda. As pequenas centrais podem suprir pequenas localidades distantes da rede, contribuindo para o processo de universalização do atendimento. Quanto às centrais de grande porte, estas têm potencial para atender uma significativa parcela do Sistema Interligado Nacional (SIN) com importantes ganhos: contribuindo para a redução da emissão, pelas usinas térmicas, de poluentes atmosféricos; diminuindo a necessidade da construção de grandes reservatórios; e reduzindo o risco gerado pela sazonalidade hidrológica, à luz da complementaridade evidenciada em trabalhos existentes na literatura. Este trabalho apresenta um modelo eficiente para simular o planejamento hidrotérmico-eólico do sistema brasileiro utilizando dados reais. São utilizadas técnicas de previsão de afluências e de velocidade do vento para simular as condições futuras do sistema, obtendo, desta maneira, um planejamento mais completo e que possa auxiliar mais adequadamente os operadores do sistema durante o processo de tomada de decisão.
GONZÁLEZ, Reinaldo Andrés Fernández. "Aplicações do Método da Entropia Cruzada na confiabilidade de Sistemas Elétricos de Potência." reponame:Repositório Institucional da UNIFEI, 2012. http://repositorio.unifei.edu.br/xmlui/handle/123456789/1161.
Full textMade available in DSpace on 2018-03-21T15:01:17Z (GMT). No. of bitstreams: 1 tese_gonzalez_2012.pdf: 2690214 bytes, checksum: 1b223db16d0e58df17656b036127790f (MD5) Previous issue date: 2012-10
Metodologias baseadas em modelos probabilísticos são extremamente úteis na avaliação do desempenho de sistemas elétricos de potência. No caso específico dos estudos de confiabilidade, as ferramentas baseadas em Simulação Monte Carlo (SMC) são muito robustas e flexíveis, principalmente para sistemas complexos e de grande porte. Estes métodos, porém, podem encontrar dificuldades no que diz respeito a eventos raros: e.g., para avaliar valores muito pequenos do índice LOLP (Loss of Load Probability), i.e., 10⁻⁵. Além disso, existe atualmente um interesse crescente por fontes de energia renováveis como, por exemplo, a geração eólica. O planejamento de um sistema com alta penetração de fontes renováveis é mais complexo devido ao grande número de variáveis aleatórias envolvidas e às flutuações nas capacidades destas fontes. Por outro lado, modelos de carga detalhados por área ou barramento têm sido uma preocupação para muitos planejadores, considerando o dimensionamento mais adequado para as redes de transmissão. As fontes de geração renováveis e os modelos cronológicos de carga são considerados dependentes do tempo devido a suas fortes correlações com variáveis climáticas e/ou temporais. Assim, novos modelos matemáticos e ferramentas computacionais precisam ser desenvolvidos a fim de tratar eficientemente estas novas tendências. Esta Tese apresenta alguns algoritmos novos e eficientes baseados em SMC e no método da Entropia Cruzada (CE – Cross-Entropy) para avaliar índices de confiabilidade em sistemas elétricos de potência. O procedimento comum em todas as metodologias é aplicar uma “distorção ótima” aos parâmetros probabilísticos dos componentes utilizando um processo de otimização estocástico baseado em CE. A amostragem dos eventos mais relevantes (i.e., eventos de falha do sistema) é assim incentivada e as propriedades de convergência dos algoritmos são melhoradas significativamente. Como resultado, as metodologias propostas podem aproveitar as características positivas de uma SMC, como a flexibilidade e a capacidade de avaliar sistemas de grande porte, mas sem sua principal limitação; o custo computacional em simulações de eventos raros. Os métodos propostos são testados em vários sistemas a fim de verificar seus desempenhos computacionais. Finalmente, sugestões de trabalhos futuros são também apresentadas e discutidas.
CRUZ, Ricardo Alexandre Passos da. "Identificação dos fluxos energéticos (origem, destino e intensidade) em sistemas elétricos de potência." reponame:Repositório Institucional da UNIFEI, 2009. http://repositorio.unifei.edu.br/xmlui/handle/123456789/1767.
Full textMade available in DSpace on 2018-10-18T19:11:47Z (GMT). No. of bitstreams: 1 dissertacao_0035395.pdf: 2379564 bytes, checksum: 62e6cf3d21f6117339479323d3521792 (MD5) Previous issue date: 2009-08
Nos estudos elétricos de fluxo de carga, os cálculos desenvolvidos não permitem saber de onde vem a energia que alimenta cada carga. Sabem-se somente os fluxos de potência nas linhas, sem que as mesmas estejam “carimbadas” ou “coloridas”. Saber de onde vem a energia, ou, de maneira dual, de onde não vem, pode ser uma informação importante para a alocação de reforços de geração (térmica principalmente), face a mudanças de critérios operativos, restrições ambientais ou face a riscos hidrológicos. No presente trabalho é apresentada uma modelagem para o cálculo do impacto em cada uma das barras, de um determinado sistema elétrico de potência, face a impactos sobre a energia firme de cada uma das centrais. Desenvolveu-se um modelo de fluxo energético, partindo-se do fluxo de carga, teórico ou real, que permite identificar a origem da energia afluente a cada ponto, permitindo, assim, saber o peso de cada geração sobre a respectiva barra. Utilizou-se Programação Linear como ferramenta matemática para a solução do problema. Este, por sua vez, consiste em minimizar a somatória dos fluxos energéticos em todos os ramos, pois não tem sentido haver circulação adicional de energia, causando perdas desnecessárias. Denomina-se isto de “mínima entropia”, pois maior circulação de energia promove aumento da entropia. As restrições são divididas em restrições de barra, onde a soma das energias que chegam e saem deve ser zero; nas linhas, a soma dos fluxos energéticos das diferentes gerações deve ser igual ao fluxo calculado ou medido. Chega-se à denominada “Matriz de impacto”, onde as linhas e colunas são respectivamente “carga” e “geração”, e seus elementos o peso de cada geração no atendimento de respectiva carga. Para facilitar a análise e o próprio tratamento numérico, desenvolveu-se uma técnica de redução do sistema elétrico, que permite agregar as barras, focando naquelas de maior interesse.
BARBOSA, Daniele de Alcântara. "Análise e desenvolvimento de metodologias de otimização aplicadas em sistemas elétricos de potência." reponame:Repositório Institucional da UNIFEI, 2009. http://repositorio.unifei.edu.br/xmlui/handle/123456789/1534.
Full textMade available in DSpace on 2018-08-13T18:26:20Z (GMT). No. of bitstreams: 1 tese_0035453.pdf: 3580942 bytes, checksum: 6adefbe3e60cceb699987a5b6a8d79c4 (MD5) Previous issue date: 2009-10
Este trabalho aborda o desenvolvimento de softwares para Fluxo Ótimo de Potência de duas formas: A primeira é através da modelagem e desenvolvimento de um software computacional mais flexível, onde mudanças em variáveis e funções objetivo sejam facilmente alteradas ou incorporadas. Isto é realizado através de um novo paradigma de modelagem e desenvolvimento de software denominado Orientação a Aspectos (Aspect-Oriented Programming AOP). A segunda é através do desenvolvimento de um algoritmo de otimização eficaz que já incorpore e minimize algumas das dificuldades existentes em outros métodos. Ou seja, uma abordagem foca a análise de software que pode ser aplicada a qualquer método de otimização e outra se concentra no desenvolvimento de um método de otimização específico que integre diversas características de outros sistemas. Da mesma forma, este trabalho apresenta duas linhas gerais, uma para cada abordagem previamente descrita, onde a integração destas produz um paradigma eficaz para a resolução de fluxo de potência ótimo.
Lopez, Sepulveda Gloria Patricia. "Aplicação de inteligência computacional na resolução de problemas de sistemas elétricos de potência /." Ilha Solteira, 2017. http://hdl.handle.net/11449/152469.
Full textResumo: Nesta tese são utilizados algoritmos de Inteligência Computacional para resolver quatro problemas da área de sistemas elétricos de potência, com o intuito de automatizar a tomada de decisões em processos que normalmente são realizados por especialistas humanos ajudados de métodos computacionais clássicos. Nesta tese são utilizados os algoritmos de aprendizado de máquina: árvores de decisão, redes neurais artificiais e máquinas de vetor de suporte, para realizar o processo de aprendizado dos sistemas inteligentes e para realizar a mineração de dados. Estes algoritmos podem ser treinados a partir das medições disponíveis e ações registradas nos centros de controle dos sistemas de potência. Sistemas Inteligentes foram utilizados para realizar: a) o controle centralizado Volt-VAr em modernos sistemas de distribuição de energia elétrica em tempo real usando medições elétricas; b) a detecção de fraudes nas redes de distribuição de energia elétrica realizando um processo de mineração de dados para estabelecer padrões de consumo que levem a possíveis clientes fraudadores; c) a localização de faltas nos sistemas de transmissão de energia elétrica automatizando o processo de localização e ajudando para que uma ação de controle da falta seja realizada de forma rápida e eficiente; e d) a coordenação de carga inteligente de veículos elétricos e dispositivos de armazenamento em tempo real utilizando a tecnologia V2G, nos sistemas de distribuição de energia elétrica a partir de medições elé... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: In this thesis Computational Intelligence algorithms are used to solve four problems of the area of power electrical systems, in order to automate decision making in processes that are usually performed by human experts aided by classical computational methods. In this thesis the machine learning algorithms are used: decision trees, artificial neural networks and support vector machines to carry out the learning process of Intelligent Systems and to perform Data Mining. These algorithms are trained from the available measurements and actions recorded in the control centers of the systems. Intelligent Systems were used to perform: a) the centralized control Volt-VAr in modern systems of distribution of electrical energy in real time using electrical measurements; b) detection of fraud in electricity distribution networks by performing a data mining process to establish patterns of consumption that lead to possible fraudulent customers; c) fault location in electric power transmission systems by automating the localization process and helping to ensure that a fault control action is performed quickly and efficiently; and d) coordination of intelligent charging of electric vehicles and storage devices using V2G technology in real-time, in electric power distribution systems using electrical measurements. For the centralized control problem Volt-VAr was tested in 42-node distribution system, for the problem of loading electric vehicles and storage devices the tests were performed... (Complete abstract click electronic access below)
Doutor