Academic literature on the topic 'Stabilité de genou'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Stabilité de genou.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Journal articles on the topic "Stabilité de genou"
Gillot, T., M. L’Hermette, and C. Tourny. "Effet de la fatigue musculaire sur la stabilité du genou : particularités de la joueuse de handball." Kinésithérapie, la Revue 17, no. 184 (April 2017): 40–41. http://dx.doi.org/10.1016/j.kine.2017.02.036.
Full textGillot, Timothée. "Effet de la fatigue musculaire sur la stabilité du genou : particularités de la joueuse de Handball." Kinésithérapie, la Revue 18, no. 194 (February 2018): 40–41. http://dx.doi.org/10.1016/j.kine.2017.12.004.
Full textAnkri, Marine, Henrique Goncalves, and Anthony Wajsfisz. "Étude du rôle des différentes structures du point d’angle postéro-latéral dans la stabilité rotatoire du genou." Revue de Chirurgie Orthopédique et Traumatologique 102, no. 8 (December 2016): S287—S288. http://dx.doi.org/10.1016/j.rcot.2016.10.042.
Full textYang, Xiong-gang, Jiang-tao Feng, Xin He, Feng Wang, and Yong-cheng Hu. "Influence des attelles de genou sur la fonction et la stabilité du genou après reconstruction du ligament croisé antérieur : revue systématique et méta analyse des études randomisées contrôlées." Revue de Chirurgie Orthopédique et Traumatologique 105, no. 6 (October 2019): 703. http://dx.doi.org/10.1016/j.rcot.2019.06.002.
Full textCavaignac, E., J. L. Tricoire, R. Pailhé, J. Murgier, N. Reina, P. Chiron, and J. M. Laffosse. "Dislocation intraprothétique récidivante sur prothèse totale de genou à charnière rotatoire. Influence du design de l’implant sur la stabilité intrinsèque." Revue de Chirurgie Orthopédique et Traumatologique 100, no. 7 (November 2014): 596–98. http://dx.doi.org/10.1016/j.rcot.2014.09.276.
Full textPison, A., and D. Saragaglia. "Contrôle de la stabilité rotatoire dans les instabilités antérieures chroniques du genou par la plastie mixte intra et extra articulaire aux ischiojambiers. Étude rétrospective de 100 cas à cinq ans de recul minimum." Revue de Chirurgie Orthopédique et Traumatologique 98, no. 8 (December 2012): S443. http://dx.doi.org/10.1016/j.rcot.2012.10.015.
Full textVentura, Alberto, Claudio Legnani, Francesca Boisio, Enrico Borgo, and Giuseppe M. Peretti. "L’ajout d’une ténodèse extra-articulaire au facia lata permet un meilleur contrôle de la stabilité rotatoire par rapport à une plastie isolée aux ischio-jambiers prélevés sur le genou controlatéral pour la chirurgie de révision des ruptures du ligament croisé antérieur." Revue de Chirurgie Orthopédique et Traumatologique 107, no. 2 (April 2021): 243. http://dx.doi.org/10.1016/j.rcot.2020.10.035.
Full textSamaei, A., A. Bakhtiary, F. Elham, and A. Rezasoltani. "Effects of Genu Varum Deformity on Postural Stability." International Journal of Sports Medicine 33, no. 06 (February 29, 2012): 469–73. http://dx.doi.org/10.1055/s-0031-1301331.
Full textHernigou, Philippe, Isaac Guissou, Tarek Nanaa, Matthieu Trousselier, Alexandre Poignard, and Charles Henri Flouzat Lachaniette. "Reprise de prothèse totale de genou par prothèse postéro-stabilisée – avantages et limites." Revue de Chirurgie Orthopédique et Traumatologique 101, no. 7 (November 2015): S192. http://dx.doi.org/10.1016/j.rcot.2015.09.130.
Full textDragosloveanu, Calin, Serban Dragosloveanu, Bogdan Cretu, and Ioana Cretu. "ORTHOPAEDIC MANAGEMENT IN EXTREME GENU VALGUM AND RECURVATUM IN A PATIENT WITH RHEUMATOID ARTHRITIS." Romanian Journal of Rheumatology 26, no. 3 (September 30, 2017): 138–41. http://dx.doi.org/10.37897/rjr.2017.3.6.
Full textDissertations / Theses on the topic "Stabilité de genou"
Gillot, Timothée. "Étude des risques de lésion du ligament croisé antérieur chez la joueuse de sports pivot Effect of fatigue on functional stability of the knee : particularities of female handball players." Thesis, Normandie, 2019. http://www.theses.fr/2019NORMR105.
Full textACL injuries are severe and highly prevalent in female handball and basketball players. The increasing participation of women in multidirectional sports conduces to a better understand the mechanism and causes of the injury. The aim of this thesis is to investigate anterior cruciate ligament injury risk among female players in multidirectional sports and its workload-induced changes. The first part is a narrative review about the dynamic process of sports injury. Epidemiologic and biomechanic approaches were used to explain the complexity of risk factors and injury mechanism interaction. These data showed the key role of neuromuscular risk factors in building the incitative event of anterior cruciate ligament injuries. The lack of knowledge about the impact of an acute workload on those risk factors in female multidirectional sports needs to be addressed.The second part is an experimental report, including two prospective studies and a systematic review using muscular assessment, systematic tools for literature review and biomechanical analysis (kinetics, kinematics and laximetry). The results showed the specificity of female handball players when performing an isokinetic fatigue protocol. The jump landing kinetic was the most impacted by a fatigue protocol. Cutting techniques were the less impacted. The analysis of 766 side-step-cutting showed that knee joint loading is anticipated (46 to 48 ms after initial contact) in female handball and basketball players. It was also shown that women performed side-step-cutting with similar knee amplitude than the injury mechanism, a less flexed trunk position and a highest angle-velocity than men.The third part of this work proposes a discussion of those results in relation to their perspectives for the prevention of anterior cruciate ligament injury risk in female handball and basketball players
Ervestrand, Jonas. "Förbättrad förbränningsstabilitet i EBK för turbofläktmotor RM12 genom förändrad motorreglering : Improved afterburner combustion stability for turbofan engine RM12 by modified engine control." Thesis, Linköping University, Department of Electrical Engineering, 2005. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-282.
Full textThe engine of JAS 39 Gripen, RM12, has recently been equipped with a new flameholder and a new engine inlet. This change has caused an increased noise level from the engine when the afterburner is in use. The noise level reaches its peak when the afterburner is partially used. The problem is thought to be unstable combustion in the regions around the flameholder. A solution to the problem has been proposed by Volvo Aero. The idea is to modify the software in the engine control unit (FADEC) that changes the airflows in the engine. This master thesis implements the proposed changes and analyzes the effects of this implementation. The analysis is done by simulations of a model of the engine that Volvo Aero has created and implemented in MatrixX/SystemBuild. Simulations showed that it is possible to achieve the desired result by the software changes. Further the simulations showed some problems with stability for the engine when controlled by the modified control unit. This was solved by implementing a filter in the FADEC software.
Pettersson, Martin. "Analyser av två VSC-HVDC-stationer genom långtidsmätningar med elkvalitetsmätare." Thesis, Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-70056.
Full textGotland has long been known for various special solutions and been on the leading edge regarding new technology. For the past 20 years Gotland has had a VSC-HVDC station that has stabilized the voltage in the Gotlandic grid. HVDC Light has solved some of the technical limitations that has hindered the growth of wind turbines. The station has almost reached the end of its technical lifespan and the thesis is a first step in the investigation for an eventual replacement. With power quality analyzers performance and improvements were investigated. The Swedish transmission system operator Svenska kraftnät have since 2016 had a VSCHVDC station that have been used to exchange energy to the asynchronous system in Eastern Europe. Svenska kraftnät has of lately wanted to take advantage of the voltage control capabilities and investigate measurement technologies. Power quality analyzers were installed on suitable connection points to investigate the behavior of the station. ELSPEC G4500 power quality analyzers were installed on Nordbalt’s and Gotland’s HVDC Light to measure during the late summer to fall of 2017. The differences between CVT and IVT, and Rogowski coil and CT were captured. The choice of ELSPEC suited well since no trigger conditions are needed which allows small but important errors to be discovered. Gotland’s HVDC Light stabilizes the grid mostly against voltage sags for faults in the 10 kVgrid and flicker from the wind farms in node 2. The rated power for an upgrade should be based on the 10 kV-grid short-circuit power to be developed during the station’s life span. The voltage control should be based on a PI-controller and should be able to transmit full power in 40 ms. Component voltages can be used to produce reactive power on the phases in need. The need against flicker should be based on measurements in the closest center of consumption, 2 miles from node 2. If it’s needed, a separate loop for flicker-control that prevents 1.5 Hz-components based on a point 1.5 mile from node 2 should be implemented. Depending on an upgrade or replacement, the topology can either be “two-level generation 3” or MMC. Many different future scenarios affect HVDC Light’s role and more resources will be required for Gotland’s and HVDC Light’s future. Two behaviors have been observed on Nordbalt where one is slow and the other behavior is fast. The fast behavior was only observed when low impedance faults occurs, that the synchronous generators also handles. Nordbalt can contribute to small voltage variations if it was faster, like the behavior for low impedance faults. A consideration in stability is needed since a faster behavior can lead to stability problems. Since the data between CVT and IVT differed a lot, metrology problems were discovered. Some solutions were discussed, of which RCVT and PQSensor was thoroughly reviewed. Alternative solutions like MoW and mobile units were also presented vaguely. All solutions showed practical difficulties, which complicates the implementation. It is therefore encouraged to test the technologies in a laboratory environment since few studies have been made on these and competing manufactures state different information.
Oscarsson, Gustav, and Patric Johansson. "Går det att förbättra postural kontroll och ankelproprioception genom balansträning på stabilt respektive instabilt underlag hos friska unga vuxna? : En randomiserad kontrollerad pilotstudie." Thesis, Luleå tekniska universitet, Hälsa och rehabilitering, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-74150.
Full textKiss, Marc-Olivier. "Évaluation de la stabilité primaire d'une greffe ostéochondrale autologue stabilisée au moyen d'un ciment ostéoconducteur résorbable." Thèse, 2011. http://hdl.handle.net/1866/8730.
Full textThe objective of this project is to compare the primary stability of osteochondral autografts stabilized with a resorbable osteoconductive bone cement to that of bottomed press fit grafts inserted according to the original mosaicplasty technique. Biomechanical testing was conducted on pairs of cadaveric bovine femurs. For each femoral pair, osteochondral grafts were inserted and stabilized with an osteoconductive bone cement (Kryptonite, DRG inc.) on one bone whereas on the controlateral femur, grafts were inserted in a press fit fashion. Grafts were inserted in 2 different configurations, single grafts as well as groups of 3 adjacent grafts, and submitted to biomechanical testing. Axial loads needed to sink the grafts to 1, 2 and 3 millimeters below cartilage level were recorded and compared according to the fixation technique, cement or press-fit impaction, for each graft configuration. According to those results, cemented osteochondral autografts appear more stable than press fit grafts for both single and 3-in-a-row configurations. Using such a cementation technique could potentially prevent the initial loss of stability that has been shown to occur with osteochondral grafts in the post-operative period, allowing patients to perform early weight bearing and rehabilitation.
Burdová, Kamila. "Studium molekulárních mechanismů udržujících stabilitu genomu." Doctoral thesis, 2014. http://www.nusl.cz/ntk/nusl-336124.
Full textUrban, Václav. "Úloha RECQ5 helikázy při udržování stability genomu." Doctoral thesis, 2016. http://www.nusl.cz/ntk/nusl-351302.
Full textŠevčík, Jan. "Funkční in vitro analýza alternativních sestřihových variant genu BRCA1." Doctoral thesis, 2012. http://www.nusl.cz/ntk/nusl-326944.
Full textFlunkert, Julia. "Analyse genetischer Stabilität in den Nachkommen bestrahlter Zellen mittels klassischer Chromosomenbänderung und verschiedener Hochdurchsatz-Techniken." Doctoral thesis, 2018. https://nbn-resolving.org/urn:nbn:de:bvb:20-opus-173670.
Full textIonizing radiation is important in medical diagnosis and cancer treatment but can lead to genomic instability and secondary malignancies as a late effect. Radiation induced genomic instability (RIGI) can be observed in the progeny of irradiated cells but the underlying cellular processes remain to be elucidated. To study delayed genetic radiation effects, single cell fibroblast clones from two different male donors were established after a single X ray dose of 2 Gray. Non irradiated cells were used as controls to account for aging related effects. Clones were characterized using chromosome banding analysis. Stable clones were endowed with no karyotype abnormalities in all analysed metaphases after 20 Population doublings, whereas unstable clones showed both normal and abnormal metaphases. Two fibroblast strains were used to detect differences in radiation sensitivity. More than half of the irradiated clones were chromosomally abnormal and thus classified as unstable. Both banding analysis and fluorescence in situ hybridization revealed an increased rate of Y chromosome loss in irradiated clones which might be associated with RIGI. Using SNP Arrays, an increased rate of de novo copy number variations (CNVs) was detected in the progeny of irradiated cells when compared to non irradiated controls. However, a significant difference between chromosomally stable and unstable clones was not found. CNVs clustered in chromosomal regions that are associated with known fragile sites. The fragile site 3B, which encompasses the gene FHIT, was found to be affected by CNVs in unstable clones suggesting a RIGI related effect. Exome sequencing of clones and the respective primary cultures revealed an increased rate of variants during in vitro aging. This effect was further increased by radiation exposure. Analysis of single nucleotides showed a RIGI independent accumulation of damage in specific regions. The results of the present study show that radiation induced changes can manifest as chromosomal abnormalities, copy number variations and DNA sequence mutations promoting tumorigenesis independent from RIGI. However, changes in FRA3B and loss of Y chromosome might trigger cancer through destabilizing the genome
Book chapters on the topic "Stabilité de genou"
Minuto, Diego, and Luca Morandi. "Geotechnical Characterization and Slope Stability of a Relict Landslide in Bimsoils (Blocks in Matrix Soils) in Dowtown Genoa, Italy." In Engineering Geology for Society and Territory - Volume 2, 1083–88. Cham: Springer International Publishing, 2015. http://dx.doi.org/10.1007/978-3-319-09057-3_192.
Full textConference papers on the topic "Stabilité de genou"
Caratozzolo, Francesco, Alberto Traverso, and Aristide F. Massardo. "Development and Experimental Validation of a Modelling Tool for Humid Air Turbine Saturators." In ASME Turbo Expo 2010: Power for Land, Sea, and Air. ASMEDC, 2010. http://dx.doi.org/10.1115/gt2010-23338.
Full textNguyen, Tri, and Elia Merzari. "Computational Fluid Dynamics Simulation of a Single-Phase Rectangular Thermosiphon." In 2020 International Conference on Nuclear Engineering collocated with the ASME 2020 Power Conference. American Society of Mechanical Engineers, 2020. http://dx.doi.org/10.1115/icone2020-16934.
Full textLarosa, Luca, Alberto Traverso, Mario L. Ferrari, and Valentina Zaccaria. "Pressurized SOFC Hybrid Systems: Control System Study and Experimental Verification." In ASME Turbo Expo 2014: Turbine Technical Conference and Exposition. American Society of Mechanical Engineers, 2014. http://dx.doi.org/10.1115/gt2014-25246.
Full textAccornero, Daniele, Mario Caruggi, Alessandro Nilberto, and Ferruccio Pittaluga. "Numerical and Experimental Investigations of Combustion Instability Phenomena in Gas Turbine Burners for Heavy Duty and Aero-Engine Applications." In ASME 2011 Turbo Expo: Turbine Technical Conference and Exposition. ASMEDC, 2011. http://dx.doi.org/10.1115/gt2011-46490.
Full textGoretzki, L., E. Miller, and A. Henschen. "CLEAVAGE PATHWAY,AND SPECIFICITY OF LEUCOCYTE ELASTASE AS COMPARED TO PLASMIN DURING FIBRINOGEN DEGRADATION." In XIth International Congress on Thrombosis and Haemostasis. Schattauer GmbH, 1987. http://dx.doi.org/10.1055/s-0038-1643897.
Full text