Dissertations / Theses on the topic 'Steel bars'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Steel bars.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Zheng, Hang. "Tempcore reinforcing steel : microstructure and mechanical properties." Phd thesis, Department of Civil Engineering, 1998. http://hdl.handle.net/2123/8671.
Full textWang, X., S. Dong, Ashraf F. Ashour, S. Ding, and B. Han. "Bond behaviors between nano-engineered concrete and steel bars." Elsevier, 2021. http://hdl.handle.net/10454/18564.
Full textThis paper investigated the bond characteristics between eight types of nanofillers modified reactive powder concrete (RPC) and plain steel bars, aiming to explore the modifying mechanisms and establish a bond-slip relationship model for nanofillers modified RPC and steel bar interface. The experimental results indicated that the incorporation of nanofillers can increase the bond strength and reduce the slip between RPC and plain steel bars. It was shown that a 2.15 MPa/20.5% of absolute/relative increase in cracking bond strength, a 1.25 MPa/10.3% of absolute/relative increase in ultimate bond strength, a 2.35 MPa/22.4% of absolute/relative increase in residual bond strength, a 0.592 mm/56.5% of absolute/relative reduction in ultimate bond slip, and a 1.779 mm/52.1% of absolute/relative reduction in residual bond slip were the best achieved due to the addition of various nanofillers. The enhancement of nanofillers on RPC-steel bar interface has been mainly attributed to RPC microstructure improvement, optimization of intrinsic compositions, and elimination of defects in the interface, especially the underside near steel bar, due to the nano-core effect of nanofillers enriched in the interface. In addition, the bond-slip relationship of nanofillers modified RPC-steel bar interface can be accurately described by the proposed model considering an initial branch.
The authors would like to thank the funding offered by the National Science Foundation of China (51978127 and 51908103), and the Fundamental Research Funds for the Central Universities (DUT21RC(3)039).
The full-text of this article will be released for public view at the end of the publisher embargo on 22 Jul 2022.
García, Taengua Emilio José. "Bond of Reinforcing Bars to Steel Fiber Reinforced Concrete (SFRC)." Doctoral thesis, Universitat Politècnica de València, 2013. http://hdl.handle.net/10251/32952.
Full textGarcía Taengua, EJ. (2013). Bond of Reinforcing Bars to Steel Fiber Reinforced Concrete (SFRC) [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/32952
TESIS
Mbewe, Peter Binali Kamowa. "Development of analytical flexural models for steel fibre-reinforced concrete beams with and without steel bars." Thesis, Stellenbosch : Stellenbosch University, 2011. http://hdl.handle.net/10019.1/18088.
Full textENGLISH ABSTRACT: There is an increasing demand for the development and use of innovative materials with reduced cost of construction while offering improved structural properties. Steel fibre reinforced concrete (SFRC) can be used as a structural material to substitute the conventional reinforcing bars partially or fully. However, there is little or no codified approach on the design procedures for SFRC members in the latest guidelines outlined in the draft 2010 Model code. It is against this background that analytical methods are derived in this study for the determination of the flexural capacity of strain-softening, deflection-hardening SFRC with and without steel reinforcing bars. Models used for the determination of the flexural capacity of SFRC rectangular sections are based on equivalent stress blocks for both compression and tensile stresses. These are derived from an elastic-perfect plastic model for compression and either an elastic-constant post-peak response or Rilem’s multi-linear model for tension, in which strain compatibility and force equilibrium theories are used. By employing the equivalent stress blocks for both tensile and compressive stress states, parameters are defined by converting the actual stress-strain distribution to an equivalent stress block, depending on the ratio of yield (or cracking) strain and post-yield (post-cracking) strains. Due to the simplicity of a drop-down tensile model and a bilinear compression model, these material models are used for the subsequent derivation of the flexural models for both SFRC with and without steel reinforcing bars. An experimental program is designed and executed for model verification. This includes material characterisation experiments for the determination of material model input parameters, and main beam flexural experiments for the determination of the beam bending capacity. An indirect tensile test is used for the characterisation of the tensile behaviour while a four-point bending test is used for beam bending behaviour. Both flexural models for SFRC with and without reinforcing bars have been verified to fairly predict the flexural capacity of the beams. However, the flexural model for SFRC with steel bars offers some challenges as to whether the synergetic effect of using both steel bars and steel fibres should be incorporated at the low fibre volumes as used in the verification exercise. Furthermore, the use of indirect methods to characterise tensile behaviour added some uncertainties in the material model parameters and hence may have affected the predictability of the model. More research on the verification of the models is required to enable the use of a wider concrete strength spectrum for the verification and possible modification of the models. Studies on the model uncertainty may also help determine the reliable safety factor for the use of the model in predicting design strength of beam sections at a prescribed reliability index.
AFRIKAANSE OPSOMMING: Daar is ‘n groeiende aanvraag na die ontwikkeling en gebruik van innoverende materiale met verminderde konstruksiekoste maar verbeterde strukturele eienskappe. Staalvesel-gewapende beton (SVGB) kan gebruik word as strukturele materiaal om die konvensionele wapeningstawe gedeeltelik of ten volle te vervang. Daar is egter min of geen gekodifiseerde benaderings tot die ontwerpprosedures vir SVGB-dele in die nuutste riglyne uitgestippel in die konsepweergawe van die 2010 Modelkode nie. Dit is teen hierdie agtergrond dat in hierdie studie analitiese metodes afgelei is vir die bepaling van die buigkapasiteit van spanning-versagtende, defleksie-verhardende SVGB met en sonder staalbewapeningstawe. Modelle wat gebruik is vir die bepaling van die buigkapasiteit van SVGB reghoekige snitte is gebaseer op ekwivalente spanningsblokke vir beide druk- en trekspannings. Hierdie is afgelei van ‘n elasties-perfekte plastiese model vir druk en óf ‘n elasties-konstante post-piek respons óf Rilem se multi-lineêre model vir spanning, waarin teorieë vir drukkapasiteit en krag-ewewig gebruik is. Deur die ekwivalente spanningsblokke vir beide trek- en drukspanningstoestande te implementeer, is parameters bepaal deur die werklike verspreiding van spanningsdruk om te wissel na ‘n ekwivalente spanningsblok, afhangend van die verhouding van swig- (of kraak-)spanning en post-swig (post-kraak) spannings. Te wyte aan die eenvoud van ‘n aftrek trekmodel en ‘n bilineêre kompressiemodel, is hierdie materiaalmodelle gebruik vir die daaropvolgende afleiding van die buigingsmodelle vir beide SVGB met en sonder staalbewapeningstawe. ‘n Eksperimentele program vir modelkontrolering is ontwerp en uitgevoer. Dit sluit eksperimente in vir materiaalbeskrywing, om invoerparameters van materiaalmodelle te bepaal, asook eksperimente vir hoofbalkbuigings, om balkbuigingskapasiteit te bepaal. ‘n Indirekte trektoets is gebruik vir die beskrywing van die trekgedrag, terwyl ‘n vierpuntbuigingstoets gebruik is vir balkbuiggedrag. Dit is bewys dat beide buigingsmodelle vir SVGB met en sonder staalbewapeningstawe die buigingskapasiteit van die balke redelik akkuraat kan voorspel. Nietemin, bied die buigingsmodel vir SVGB met staalbewapeningstawe sekere uitdagings: die vraag ontstaan rondom die insluiting van die sinergetiese effek van die gebruik van beide staalstawe en staalvesels met die lae veselvolumes soos gebruik in die kontroleringsoefening. Verder het die gebruik van indirekte metodes om die buigingsgedrag te bepaal, onsekerhede gevoeg by die materiaalmodelparameters en dit mag dus as sulks die voorspelbaarheid van die model beïnvloed. Meer navorsing moet uitgevoer word oor die kontrolering van die modelle sodat ‘n wyer spektrum van betonsterkte gebruik kan word vir die verifikasie en moontlike aanpassing van die modelle. Navorsing oor die wisselvalligheid van die modelle mag ook help om die betroubare veiligheidsfaktor te bepaal vir die model se gebruik in die berekening van ontwerpkrag van balkdele teen ‘n voorgeskrewe betroubaarheidsindeks.
Nachiappan, Vijayakumar. "Corrosion of high-chromium and conventional steels embedded in concrete." Morgantown, W. Va. : [West Virginia University Libraries], 2003. http://etd.wvu.edu/templates/showETD.cfm?recnum=3195.
Full textTitle from document title page. Document formatted into pages; contains ix, 56 p. : ill. (some col.). Includes abstract. Includes bibliographical references (p. 51-52).
Wuertz, Augustine F. "Strengthening rectangular beams with NSM steel bars and externally bonded GFRP." Thesis, Kansas State University, 2013. http://hdl.handle.net/2097/15624.
Full textDepartment of Civil Engineering
Hayder Rasheed
The technology of FRP strengthening has matured to a great extent. However, there is always room for performance improvements. In this study, external bonding of GFRP and near surface mounting (NSM) of regular steel bars is combined to improve the behavior, delay the failure, and enhance the economy of the strengthening. E-Glass FRP is selected due to its inexpensive cost and non-conductive properties to shield the NSM steel bars from corrosion. On the other hand, the use of NSM bars gives redundancy against vandalism and environmental deterioration of the GFRP. An experimental program is conducted in which four rectangular cross-section beams are designed, built, and tested in four-point bending. The first beam is tested as a control beam failing at about 12.24 kips. The second beam is strengthened using two #5 steel NSM bars and 1 layer of GFRP, both extending to the support. This beam failed at 31.6 kips. The third beam is strengthened with the same system used for the second beam. However, the NSM steel bars were cut short covering 26% of the shear-span only while the GFRP was extended to the support. This beam failed at 30.7 kips due to reaching the full flexural capacity of the section at the NSM bars cut off point and the shear stress concentration at the steel bar cut off point. The fourth beam was strengthened with same system as the third beam but then submerged in a highly concentrated saline solution for six months and then tested. This beam failed at a maximum applied load of 29.8 kips, which shows that the GFRP sheet provided good corrosion resistance from the saline solution.
Araba, Almahdi M. A. A. "Behaviour of continuous concrete beams reinforced with hybrid GFRP/steel bars." Thesis, University of Bradford, 2017. http://hdl.handle.net/10454/16920.
Full textSong, Mengli. "Effectiveness of steel bars in reinforced masonry walls under concentric compression." Thesis, Queensland University of Technology, 2019. https://eprints.qut.edu.au/132724/1/Mengli_Song_Thesis.pdf.
Full textAbosrra, L. R. "Corrosion of steel reinforcement in concrete : corrosion of mild steel bars in concrete and its effect on steel-concrete bond strength." Thesis, University of Bradford, 2010. http://hdl.handle.net/10454/5417.
Full textHayford, Frank. "CLEANLINESS ASSESSMENT OF STEEL BARS PRODUCED FROM A HIGH FREQUENCY INDUCTION FURNACE." Thesis, KTH, Tillämpad processmetallurgi, 2011. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-125018.
Full textTraplsi, Abdelbaset Mahmoud. "Combined NSM steel bars and externally bonded GFRP in strengthening T beams." Thesis, Kansas State University, 2012. http://hdl.handle.net/2097/15170.
Full textDepartment of Civil Engineering
Hayder A. Rasheed
Nowadays, using the technology of FRP strengthening has become acknowledged by engineers and has reached a full acceptance. However, researchers are always looking for improvement in performance. In this study, external bonding of GFRP and near surface mounting of regular steel bars are combined to improve the behavior, delay the failure and enhance the economy of the strengthening. E-Glass FRP is selected due to its inexpensive cost and non-conductive properties to shield the NSM steel bars from corrosion. On the other hand, the use of NSM bars gives redundancy against vandalism and environmental deterioration of GFRP. An experimental program was conducted in which four full scale T beams were designed and built. All four specimens were fabricated with Grade 70 steel reinforcement and 8000 psi concrete. Only one beam was loaded beyond first cracking then exposed to highly concentrated deicing salt water to accelerate the corrosion process. All beams were tested by monotonic loading until failure. The load rate was 1 kips/min. The first specimen is tested as a control beam failing at about 15 kips. The second specimen is strengthened using two #5 steel NSM bars and 1 layer of GFRP, both extending to the support. This beam failed at 38.4 kips by GFRP debonding. The third specimen is strengthened with the same system used for the second beam. However, the NSM steel bars were cut short covering only 30% of the shear-span while the GFRP was extended to the support. This beam failed at 25.9 kips by GFRP debonding and NSM delamination due to the lack of sufficient development of the NSM steel bars and the shear stress concentration at the steel bar cut off point. Nevertheless, the fourth beam is strengthened with the same system used for the third beam. The fourth specimen was exposed to severe attack of deicing salt by immersing it in concentrated deicing salt solution for three continuous months. In order to accelerate the corrosion process, the beam was loaded beyond its cracking load before the corrosion procedure. After the completion of the three months, the beam was tested monotonically to failure. It failed at 23.2 kips indicating that some deterioration might have taken place. The failure mode was by GFRP debonding and NSM delamination like the case of Beam 3.However, it was observed after failure that the NSM bars were very well protected by the surrounding epoxy.
Ge, W., K. Chen, Z. Guan, Ashraf F. Ashour, W. Lu, and D. Cao. "Eccentric compression behaviour of concrete columns reinforced with steel-FRP composite bars." Elsevier, 2021. http://hdl.handle.net/10454/18412.
Full textEccentric compression behaviour of reinforced concrete (RC) columns reinforced by steel-FRP composite bars (SFCBs) was investigated through experimental work and theoretical analyses. The tension and compression test results show that SFCBs demonstrate a stable post-yield stiffness. The mechanical properties of the composite reinforcement have a significant influence on eccentric compression behaviour of the reinforced concrete columns, in terms of failure mode, crack width, deformation and bearing capacity. Formulae were also developed to discriminate failure mode and to determine moment magnification factor, bearing capacity and crack width of the columns studied, with the theoretical predictions being in a good agreement with the experimental results. In addition, parametric studies were conducted to evaluate the effects of mechanical properties of reinforcement, reinforcement ratio, eccentricity, slenderness ratio, types of reinforcement and concrete on the eccentric compression behaviour of RC columns. The results show that the compressive performance is significantly improved by using the high performance concrete, i.e. reactive powder concrete (RPC) and engineered cementious composites (ECC).
financial supports of the work by the National Natural Science Foundation of China (51678514), the Natural Science Foundation of Jiangsu Province, China (BK20201436), the China Postdoctoral Science Foundation (2018M642335), the Science and Technology Project of Jiangsu Construction System (2018ZD047), the Deputy General Manager Science and Technology Project of Jiangsu Province (FZ20200869), the Cooperative Education Project of Ministry of Education, China (201901273053), the Blue Project Youth Academic Leader of Colleges and Universities in Jiangsu Province (2020), the Six Talent Peaks Project of Jiangsu Province (JZ-038, 2016), the Yangzhou University Top Talents Support Project and the Jiangsu Government Scholarship for Overseas Studies.
The full-text of this article will be released for public view at the end of the publisher embargo on 3 Apr 2022.
El-Nemr, Amr Maher. "Serviceability of concrete members reinforced with FRP bars." Thèse, Université de Sherbrooke, 2013. http://hdl.handle.net/11143/6124.
Full textAmleh, Lamya. "Influence of corrosion of reinforcing bars on the bond between steel and concrete." Thesis, McGill University, 1996. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=24050.
Full textLess, Thomas Matthew. "Structural Performance and Corrosion Resistance of Fiber Reinforced Polymer Wrapped Steel Reinforcing Bars." The Ohio State University, 2013. http://rave.ohiolink.edu/etdc/view?acc_num=osu1366222349.
Full textShah, Falak Dipak. "Time-dependent behavior of pretensioned stainless steel bars used for structural rehabilitation and retrofitting." Diss., Georgia Institute of Technology, 2014. http://hdl.handle.net/1853/53063.
Full textBelghiti, Moulay El Mehdi. "Influence of steel fibres on response of beams." Thesis, McGill University, 2007. http://digitool.Library.McGill.CA:80/R/?func=dbin-jump-full&object_id=100222.
Full textThis research project demonstrated a clear improvement of the shear capacity resulting from the use of steel fibres for the beams without transverse reinforcement. For the beams with transverse reinforcement, displacement ductility was highly increased. This suggests that fibres have the potential to reduce the congestion of the reinforcement if fibres are designed to replace partially closely spaced transverse reinforcement. Also, it was noted that a redistribution of stresses occurred resulting in the formation of more well-controlled cracks. Finally, the strength predictions using the method developed by Aoude (Aoude, 2007) agree very well with the experimental results.
Wassouf, Mohamad. "Bond and ductility of concrete reinforced with various steel bars surface and ductility conditions." Thesis, University of Birmingham, 2015. http://etheses.bham.ac.uk//id/eprint/6272/.
Full textKhanna, Om Shervan. "Experimental investigation of transverse confinement in deck slabs by glass fibre reinforced polymer and steel bars." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1999. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape8/PQDD_0007/MQ42717.pdf.
Full textLi, Jing, and 李靜. "Effects of diagonal steel bars on performance of interior beam-column joints constructed with high-strength concrete." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2003. http://hub.hku.hk/bib/B31244464.
Full textWeidenmüller, Jens [Verfasser]. "Optimization of Encircling Eddy Current Sensors for Online Monitoring of Hot Rolled Round Steel Bars / Jens Weidenmüller." Aachen : Shaker, 2014. http://d-nb.info/1058316036/34.
Full textMoallemi, Pour Sadaf. "Investigation of compressive bond behavior of steel and fiber reinforced polymer bars embedded in recycled aggregate concrete." Thesis, University of British Columbia, 2016. http://hdl.handle.net/2429/57927.
Full textApplied Science, Faculty of
Engineering, School of (Okanagan)
Graduate
Abushoglin, Fathi. "Computer-aided nonlinear analysis of simple beams and one way slabs reinforced by FRP and/or steel bars." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk2/tape17/PQDD_0003/MQ32391.pdf.
Full textDing, Yongcong. "Residual stresses in hot-rolled solid round steel bars and their effect on the compressive resistance of members." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 2000. http://www.collectionscanada.ca/obj/s4/f2/dsk1/tape3/PQDD_0030/MQ62207.pdf.
Full textAbushoglin, Fathi Carleton University Dissertation Engineering Civil and Environmental. "Computer-aided nonlinear analysis of simple beams and one way slabs reinforced by FRP and/or steel bars." Ottawa, 1997.
Find full textAndreolli, Mauro. "Giunti semirigidi con barre incollate per strutture lignee = Ductile moment-resistant steel-timber connections with glued-in bars." Doctoral thesis, Università degli studi di Trento, 2011. https://hdl.handle.net/11572/368695.
Full textAndreolli, Mauro. "Giunti semirigidi con barre incollate per strutture lignee = Ductile moment-resistant steel-timber connections with glued-in bars." Doctoral thesis, University of Trento, 2011. http://eprints-phd.biblio.unitn.it/509/1/PhD_Thesis_ANDREOLLI.pdf.
Full textHabeeb, M. N. "Flexural behaviour of continuously supported FRP reinforced concrete beams." Thesis, University of Bradford, 2011. http://hdl.handle.net/10454/5727.
Full textOLIVEIRA, WALTER EDGLEY DE. "EXPERIMENTAL STUDY ON THE INFLUENCE OF CONCRETE COVER ON THE INTERACTION BETWEEN STEEL BARS AND CONCRETE IN ELEMENTS SUBJECTED TO COMPRESSION." PONTIFÍCIA UNIVERSIDADE CATÓLICA DO RIO DE JANEIRO, 2008. http://www.maxwell.vrac.puc-rio.br/Busca_etds.php?strSecao=resultado&nrSeq=13067@1.
Full textCONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO
O presente trabalho trata da influência do cobrimento da armadura longitudinal sobre a resistência de aderência em regiões de emenda por traspasse de elementos de concreto armado comprimidos. Neste estudo foram ensaiados dezoito pilares de concreto armado com seção transversal de 200 mm x 150 mm e comprimento de 1100 mm, com armadura longitudinal composta de barras de aço CA-50 com diâmetro nominal de 12,5 mm e estribos de 5 mm. O arranjo da armadura longitudinal definiu três séries de pilares, sendo a Série 1 composta por seis pilares com a armadura longitudinal contÃnua, e as Séries 2 e 3 cada uma composta por seis pilares com a armadura longitudinal, tendo uma emenda por traspasse localizada na região da metade da altura do pilar de 470 cm e 235 mm de comprimento, respectivamente. Os ensaios consistiram na aplicação de uma força de compressão com uma excentricidade de 20 mm, sendo tal excentricidade aplicada apenas na direção da menor dimensão da seção transversal. Para os seis pilares de cada série o cobrimento da armadura longitudinal variou de 25 mm até que a metade do diâmetro da barra longitudinal ficasse exposta. Os resultados obtidos indicam que a influência do cobrimento sobre a capacidade do pilar resistir à s solicitações torna-se visÃvel quando a relação c/ à da espessura do cobrimento c e do diâmetro da barra à é inferior a 0,4. Para pilares com barras emendadas por traspasse e com armadura exposta até a metade de seu diâmetro, a aderência na zona da emenda foi substancialmente afetada, provocando a ruptura do pilar sob forças inferiores à s alcançadas em pilares com cobrimento adequado.
The present work describes the influence of the concrete cover of the longitudinal reinforcement on the bond strength along the overlapping splice zones of compressed elements. Tests have been carried out on eighteen reinforced concrete columns, with cross section of 200 mm x 150 mm and 1100 mm of length. The longitudinal reinforcement consisted of CA-50 steel bars with nominal diameter of 12,5 mm and stirrups of 5 mm. Three series of columns (Serie 1, Serie 2 and Serie 3) were defined according to the arrangements of the longitudinal reinforcement: Series 1 composed by six columns with continuous longitudinal reinforcement; Series 2 and 3 composed by six columns each, presenting an overlapping splice of 470 mm and 235 mm of lenght, respectively. The columns were submited to a load apllied with an eccentricity of 20 mm in the direction of the smallest dimension of the cross section. In each series, the concrete cover varied from 25 mm to a value corresponding to the situation in which half of the diameter of the longitudinal bar was exposed. The results showed that the influence of the concrete cover on the column strength becomes relevant when the ratio c/ à of the cover thickness c to the bar diameter à is less than 0,4. For columns with overlapping splice and reinforcement exposed up to the half of diameter, the bond along the overlapping zone has been substancially affected, resulting in the column failure at lower loads when compared to columns with proper value of concrete cover.
Walker, Jason Matthew. "Evaluation of elliptical, glass fiber reinforced polymer, and stainless steel dowel bars in concrete pavements with consideration to subgrade resilient modulus." [Ames, Iowa : Iowa State University], 2008.
Find full textImohamed, Imohamed Ali Omar <1981>. "Experimental Study of the Bond Behaviour of Steel FRP-Concrete Joints and Shear Behavior of Concrete Beams Reinforced with GFRB Bars." Doctoral thesis, Alma Mater Studiorum - Università di Bologna, 2017. http://amsdottorato.unibo.it/7857/1/Imohamed_ImohamedAliOmar_tesi.pdf.
Full textYosefani, Anas. "Flexural Strength, Ductility, and Serviceability of Beams that Contain High-Strength Steel Reinforcement and High-Grade Concrete." PDXScholar, 2018. https://pdxscholar.library.pdx.edu/open_access_etds/4402.
Full textGravina, Rebecca Jane. "Non-linear overload behaviour and ductility of reinforced concrete flexural members containing 500MPa grade steel reinforcement." Title page, contents and abstract only, 2002. http://web4.library.adelaide.edu.au/theses/09PH/09phg777.pdf.
Full textHeathcote, Lydia. "An Inductive Scanning System for Detection of Corrosion in Reinforcing Steel Bars at Distances of up to 90mm and a Procedure to Extract Bar Dimensional Information." Thesis, University of Manchester, 2010. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.525292.
Full textRivera-Corral, Jesus Octavio. "Contribution à l'évaluation de l'état de dégradation de divers types de barres d'acier utilisées comme armatures dans des bétons carbonatés ou pollués par des chlorures." Thesis, Toulouse 3, 2016. http://www.theses.fr/2016TOU30210/document.
Full textCorrosion of reinforcing bars in concrete is considered as the most important problem that affects the integrity of the civil structures. In order to obtain a better resistance to corrosion, various superficial processes as coatings with zinc (AG) or such as the dual covering metallic-polymeric (AD) are applicate to ordinary steel bars (AC). On the other hand, steel bars with thermal treatments (ATT), principally developed as an alternative to improve the mechanical properties without the use of ferroalloys, are not used in concrete. The behavior of these kinds of bars in front of mechanisms of deterioration as the corrosion induced by chlorides or carbonation has not yet been studied. In this work, all these various steel bars (AG, AD, AC and ATT) were embedded in prismatic specimens of concrete made with two ratio water/cement: 0.45 and 0.65. Previously, steels bars were characterized by mechanical tests and metallographic identifications. Then, specimens were placed in several sites of exposition: urban/industrial environment, or coastal environment, or controlled atmosphere in laboratory. During these expositions, measurements of corrosion potential, linear polarization resistance, and electrochemical impedance spectroscopy were regularly carried out. For each type of steel bar, chloride threshold level and progress of the carbonation depth were determined. Furthermore, by means of the induction of a galvanic couple during design of new samples, the electrochemical behavior of the steels bars AC, ATT and AG was followed up experimentally and then analyzed with finite element model. It was founded that the different steels bars exposed in controlled atmosphere of laboratory followed a same sequence in depassivation for both ratios water/cement: ATT, AC, AG and AD. The chloride thresholds were higher for steels bars AG and AD. However, visual inspection showed that the morphology of damages caused on AG bars was most important compared with the other steel bars. In the propagation phase, the corrosion current density of the ATT bars was lower, even to that obtained by the AG bars
Pappas, Adlreburg Nickolas. "To Make Iron of Iron : A Comprehensive Analytical Study of Spade Shaped Iron Bars." Thesis, Stockholms universitet, Arkeologiska forskningslaboratoriet, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-145694.
Full textGudelis, Andrius. "Klijuotųjų medienių sijų jungties su įklijuotaisiai plieniniais strypais tyrimas." Master's thesis, Lithuanian Academic Libraries Network (LABT), 2009. http://vddb.library.lt/obj/LT-eLABa-0001:E.02~2009~D_20090702_141646-55416.
Full textIn this master degree paper are discussed advantages and imperfections, practice and use in construction industry of glulam with glued-in steel rods. Theoretical calculations analysis according to Eurocode and Russian standards of glued-in steel rods parallel, perpendicular and at an angle to the grain were made. Theoretical calculations of rigid joint glulam beam with glued-in steel bars were made. Tests methods were analyzed. In the part of the researches these tests were made: yield stress evaluation test of steel rods; moisture and density evaluation tests of wood; parallel, perpendicular ant at an 45 o angle to the grain compression tests of the glued-in steel rods; rigid joint of the glulam beam with glued-in steel rods test. Fundamental factors, which have influence to the results of the tests, character of the disruptions and the behavior of elements during the experiments were defined. The results of the calculations were compared with the results of tests in which natural size specimens were tried. In this work the results of theoretical calculations and experimental tests are proposed, evaluated and analyzed. The reasons of divergence in results are indicated. Recommendations and suggestions how to improve the methods of calculations and for better use the glued-in steel rods in the practice were offered.
Popovič, Tomáš. "Návrh konstrukce pro fotbalové hřiště." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2016. http://www.nusl.cz/ntk/nusl-240365.
Full textSILVA, Juliano Rodrigues da. "Estudo Experimental de Pavimentos de Concreto: Influência da Posição da Barra de Transferência e do Tipo de Concreto." Universidade Federal de Goiás, 2009. http://repositorio.bc.ufg.br/tede/handle/tde/681.
Full textThis work presents an experimental study of the behavior of transverse joints in unreinforced concrete slabs under elastic support. Due to the tensions caused by loads and volumetric variations in the slab, transverse joints when badly executed can cause a efficiency reduction in the shear transfer, thus reducing the useful life of the concrete pavement. To have a better efficiency in the shear transfer in joints of concrete pavements, 500 mm transfer bars are used with bar diameters varying from 10 mm to 32 mm. These bars are positioned at midheight of the sawed joints spaced at every 300 mm. This research seeks to verify the influence of the positioning of the transfer bars and the influence of different types of concrete on sawed joints of concrete pavements. Three different types of unreinforced concrete were used: conventional concrete, steel fiber concrete and self-compacting concrete. The experimental program consisted of the application of static monotonic loading in nine concrete plates, simulating concrete pavements, with dimensions 2200 mm x 600 mm, with a sawed joint at midlength supported by an elastic rubber layer. The experimental results showed that joints with transfer bars performed much better than those joints without transfer bars and that bars located at midheight perform better than those bars positioned at 45 mm from the base. The concrete types were quite different, however the steel fiber concrete was shown to be more efficient than the other two concrete types, and the conventional concrete was more efficient than self-compacting concrete, probably because aggregate interlock is better in conventional concrete
Este trabalho apresenta um estudo experimental do comportamento de juntas transversais em placas de concreto simples, apoiadas sobre uma fundação elástica. Devido às tensões provocadas pelo carregamento e por variações volumétricas das placas, as juntas transversais quando mal executadas podem ocasionar uma redução da eficiência da transferência de esforços, reduzindo assim, a vida útil do pavimento de concreto. Para que ocorra uma melhor eficiência da transferência dos esforços nas juntas transversais são utilizadas barras de transferência com diâmetro comercial variando de 10 mm a 32 mm e comprimento de 500 mm. Essas barras são posicionadas sob as juntas serradas na altura de ½ da espessura da placa de concreto e posicionadas a cada 300 mm uma da outra. Esta pesquisa visa verificar a influência das juntas serradas em função do posicionamento das barras de transferência e a influência do uso de concreto simples autoadensável, concreto simples convencional e concreto convencional simples com fibras de aço. O programa experimental constou de ensaios com aplicação de carregamento estático monotônico em nove placas, simulando pavimentos de concreto, com dimensões 2200 mm x 600 mm, dotadas de junta transversal serrada e apoiadas sobre uma camada de borracha. Os ensaios experimentais mostraram que a junta serrada em placas com a presença de barras de transferência tem um desempenho muito melhor do que as placas sem barra de transferência, e que quanto à altura das barras em relação à base, tiveram um melhor desempenho nas barras posicionadas a ½ altura que a 45 mm da base. Os tipos de concreto foram bastante distintos, porém o concreto convencional com fibras se mostrou mais eficiente que os outros dois tipos de concreto, e o concreto convencional se mostrou mais eficiente que o concreto autoadensável, provavelmente em função do intertravamento dos agregados do concreto convencional que são mais solicitados do que os agregados do concreto autoadensável
Beyer, André. "Résistance des barres en acier à section ouverte soumises à une combinaison d’effort normal, de flexion et de torsion." Thesis, Université de Lorraine, 2017. http://www.theses.fr/2017LORR0204/document.
Full textStructural steel members with open cross-section are, in the majority of cases, subject to a combination of axial forces and mono- or bi-axial bending. Nonetheless, owing to specific use they may be subject to torsion as well. Even if torsional loads are of practical interest for steel members of open section, the European standard for the design of steel structures, Eurocode 3, does not contain a generally accepted design method addressing the resistance of these members. Consequently, the main objective of this thesis is to close the lack in the current standard. So as to attain this objective the behaviour of members of open section subject to a complex load combination has been studied theoretically, experimentally and numerically. First, the plastic resistance of steel members has been analysed. It has been shown that members subject to torsion may possess a high plastic system reserve that cannot be predicted by simple elastic analysis. So as to account for the beneficial effect of the plastic reserve, a simplified analysis method has been developed and validated with numerical simulations. After this, the plastic interaction between all internal forces and moments has been studied. Several laboratory tests have been performed to characterise the interaction between bending moments and the shear force. The study is then extended to more complex interaction cases including torsion by means of numerical simulations. The laboratory test and the numerical simulations allowed the development of a precise resistance model based on the “Partial Internal Force Method” developed in the past. The last part of this thesis was dedicated to the member resistance including instability. A resistance model has been developed based on the Eurocode 3 interaction equations. So as to overcome some of the limitations linked to this method, a second design approach is developed based on the “Overall Interaction Concept”
Petrík, Tomáš. "Pavilon šelem v zoologické zahradě Lešná." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2013. http://www.nusl.cz/ntk/nusl-226062.
Full textCOSTA, ISOLDA. "Effect of minor addition elements on the corrosion behaviour of bare and coated steels." reponame:Repositório Institucional do IPEN, 1991. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10281.
Full textMade available in DSpace on 2014-10-09T13:56:00Z (GMT). No. of bitstreams: 1 04366.pdf: 5734662 bytes, checksum: 226af9141e1984ce9dff1230b5f437ed (MD5)
Tese (Doutoramento)
IPEN/T
University of Manchester, England
Miàs, Oller Cristina. "Analysis of time-dependent flexural behaviour of concrete members reinforced with fibre reinforced polymer bar." Doctoral thesis, Universitat de Girona, 2012. http://hdl.handle.net/10803/96914.
Full textEn aquest treball, es presenta una nova metodologia per a la determinació de fletxes diferides degudes als efectes de la fluència i la retracció del formigó. La metodologia presentada es basa en coeficients multiplicadors, essent així un mètode directe i simple, apte per ser utilitzar en el disseny. Addicionalment, l’estudi presenta els resultats d’una campanya experimental realitzada en dues etapes, on bigues armades amb barres de material compost han estat sotmeses a càrregues a llarg termini. S’han considerat diferents quanties de reforç, resistències de formigó i nivells de càrrega. Per tal de comparar-ne els resultats, també s’han assajat bigues armades amb barres d’acer. Els resultats experimentals han estat analitzats i comparats amb els models de predicció més significatius, així com amb la metodologia desenvolupada i presentada en aquest estudi.
Shi, Feifei. "Comportement des tôles métalliques à gradient de propriété sous chargement dynamique." Thesis, Cachan, Ecole normale supérieure, 2015. http://www.theses.fr/2015DENS0035/document.
Full textThis Ph.D dissertation aimed at the comprehensive understanding and the constitutive modeling of the mechanical behaviours of the surface mechanical attrition treatment (SMAT) treated AISI304 stainless steel sheet under a large range of loading rates. SMAT treated AISI304 stainless steel sheets are multi-layered functionally graded materials (FGM). The main research results and conclusions are summarized as followed:(1) The overall rate sensitivity SMAT treated AISI304 stainless steel sheet is characterized by the double shearing test under quasi-static and dynamic loading where a large strain can be achieved without geometry instability. Impact double shear test are performed with a large diameter Hopkinson bar system and an adapted equal-impedance clamping device. Significant rate sensitivity is found. It is also observed that such a rate enhancement does not induce an important reduction of the ductility.(2) In order to extract accurate material information from the double shear tests, their testing conditions are thoroughly analyzed using numerical simulation. Numerical models including clamping devices have been built to investigate the influence of this clamping device at the early stage of loading. A limited effect was found for various imperfect testing conditions such as the clamping device stiffness, non-homogeneous stress and strain fields, non-equilibrium state, etc. On the contrary, numerical and analytical study shows that the simple small strain assumption usually used in double shear tests are not accurate enough. Eulerian cumulated strain definition should be used to get consistent numerical results. From this finding, the experimental rate sensitivity obtained for the SMAT treated AISI304 stainless steel sheet are recalculated.(3) A multi-layers elastic plastic damageable constitutive model is proposed to model SMAT treated AISI304 stainless steel sheet. The parameters are identified using tensile testing results. The elastic plastic behavior is curve fitted with a simple Ludwig hardening model. However, the damage parameters should be identified using an inverse method on the basis of numerical simulation of these tensile tests. In order to validate this multi-layer elastic plastic damageable constitutive model, indentation/piercing tests on SMAT treated AISI304 stainless steel sheet are performed. Numerical simulation of this indentation/piercing tests is also realized. It is found that the identified multi-layer elastic plastic damageable constitutive model allows for a quite accurate prediction of the experimental piercing tests.(4) In order to evaluate the impact anti-piercing capacity of the SMAT treated AISI304 stainless steel sheet, the impact perforation tests using Hopkinson bar are carried out. Numerical simulation of these impact perforation tests are realized with a similar FEM model as the quasi-static case. As the rate sensitivity of SMAT treated AISI304 stainless steel sheet is experimentally characterized with double shear test, a rate sensitive multi-layer elastic plastic damageable constitutive model is introduced. The numerical results agree well with the experimental ones, which indicates the effectiveness of the numerical model as well as the rate sensitive multi-layer elastic plastic damageable constitutive model
Baxant, Radek. "Řešení stability prutových konstrukcí." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2015. http://www.nusl.cz/ntk/nusl-227507.
Full textBettanin, Viviane. "Tanino da ac?cia negra como inibidor da corros?o de a?o API5L X65 em meio ?cido." Pontif?cia Universidade Cat?lica do Rio Grande do Sul, 2018. http://tede2.pucrs.br/tede2/handle/tede/8353.
Full textApproved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-11-19T13:58:36Z (GMT) No. of bitstreams: 1 Disserta??o homologa??o Viviane Bettanin 14.11.2018.pdf: 3436850 bytes, checksum: 12199a52b8023657a598a8254ca85c0f (MD5)
Made available in DSpace on 2018-11-19T14:07:36Z (GMT). No. of bitstreams: 1 Disserta??o homologa??o Viviane Bettanin 14.11.2018.pdf: 3436850 bytes, checksum: 12199a52b8023657a598a8254ca85c0f (MD5) Previous issue date: 2018-08-29
Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES
In order to reduce the environmental impacts caused by chemical harmful to the environmental and to human health, the development of natural substances that are able to substitute these dangerous components have been increased. Tannins are a group of natural poliphenolic components extracted from plants that could be used as corrosion inhibitors. This study investigates the utilization of two bark of black wattles (Acacia mearnsii) as corrosion inhibitors, Weibull and Macrospec, in acidic medium and in atmospheric environment and in aqueous CO2 rich medium under high pressure. API 5L X65 steel samples were exposed to a corrosive medium (0.1 M HCl) with different tannin concentrations. The best results were duplicate to an environmental with CO2 saturated water at 15 MPa and 50?C. In order to characterize the specimens scanning electron microscopy by gun field emission, energy dispersive spectroscopy, X ray diffraction, mass loss tests and potenciodynamic polarization tests were used. The results indicated that both tannins, at atmospheric pressure and 0.1 M HCl corrosive environment have similar performance as corrosion inhibitors, and the higher dosage tested (12 g/L) exhibited the best efficiency. However, when the tannins were tested in environment with presence of CO2 under high pressure (15 MPa) and 50?C the results were different, and only Macrospec tannin had an inhibitory action under the conditions tested.
Visando diminuir os impactos ambientais causados por subst?ncias qu?micas nocivas ao meio ambiente e ? sa?de humana, a procura por substitutos naturais destes compostos em diversas aplica??es vem sendo intensificada. Taninos compreendem uma classe de compostos polifen?licos naturais extra?dos de plantas, podendo ser usados como inibidores de corros?o em meio aquoso. Neste estudo avaliou-se a utiliza??o de dois taninos vegetais da ac?cia negra (Acacia mearnsii), Weibull (em p?) e Macrospec (l?quido), como inibidores de corros?o em meios ?cidos em ambiente atmosf?rico e em ambiente com a presen?a de CO2 a alta press?o. Corpos de prova de a?o API5L X65 foram expostos a meio acidificado com HCl 0,1 M com diferentes concentra??es de taninos e o melhor resultado no que se refere ? concentra??o do tanino para a inibi??o de corros?o foi replicado para um meio com ?gua saturada com CO2 a 15 MPa e 50?C. Para caracteriza??o foram realizadas as an?lises de microscopia eletr?nica de varredura, difra??o de raios X, medidas eletroqu?micas de polariza??o potenciodin?mica, e testes de perda de massa. Os resultados indicaram que ambos os taninos, em meio de HCl 0,1 M e press?o atmosf?rica, apresentaram desempenho similar no que diz respeito aos efeitos de inibi??o da corros?o e a maior dosagem utilizada (12 g/L) foi a que apresentou melhor efici?ncia de inibi??o. Por?m, quando testados em meio de ?gua saturada com CO2 a 50?C e 15 MPa o comportamento dos taninos foi distinto, sendo que apenas o tanino Macrospec teve a??o inibit?ria nas condi??es testadas.
Tunková, Martina. "Městské lázně." Master's thesis, Vysoké učení technické v Brně. Fakulta architektury, 2010. http://www.nusl.cz/ntk/nusl-215713.
Full textHsieh, Man-yun, and 謝嫚紜. "Compression behavior of corroded steel deformed bars." Thesis, 2014. http://ndltd.ncl.edu.tw/handle/52342192450196648678.
Full text國立臺灣科技大學
營建工程系
102
This research uses the steel tension and compression test to investigate the effects of corrosion bars. Through use the electrochemical method to achieve the bars corrosion behavior. There are 6 groups of RC specimens. It contain three different weight loss rete are 10%, 20% and 30% respectively. Remove corrosion bars from RC specimens and do the bars tension and compression test. Then directly test none corrosion bars. Currently, there is only one group of RC specimens (10% of the corrosion ratio) take into test, containing 8 bars for each longitudinal and transverse bar. Randomly select the bar from none corrosion and 10% of the corrosion ratio of longitudinal bar to test. As the result, the ultimate stress and yield stress of the corrosion bars is slightly less than none corrosion bar in tensile test. But the strain difference between it is approximately 10%. And the stress of none corrosion bar is generally greater than the corrosion bar in compression test. Compare the terms of the deformation curve, the deformation of longer length of the unsupported steel are also larger.
Yang, Li Tai, and 楊禮黛. "Bond Behavior Between Steel bars and Steel Fiber Reinforced High Performance Concrete." Thesis, 1999. http://ndltd.ncl.edu.tw/handle/17011357398822957935.
Full text國立臺灣科技大學
營建工程系
87
In this research, macro mechanics behavior and micro interface of steels and local concrete TAICON with the addition of steel fiber is investigated. The aim is to understand the change of bonding behavior after different amount of steel fiber is added in TAICON and conventional concrete. Besides, through micro observation, the mechanism of bonding behavior is analyzed and discussed. The results indicate for both TAICON mixed by Densified Mixture Design Algorithm (DMDA) and conventional concrete that has followed the ACI specification, slump and slump flow loss occur after steel fiber is added. However, for TAICON, after 1.5% steel fiber is added, the workability can be maintained, but for conventional concrete, after mixing and compacting process, honey comb, cave and bleeding appear, and tensile resistance, toughness and crack resistance of fiber concrete can not be improved, consequently influencing the quality and durability of concrete. The interfacial bonding of steel and concrete is an important factor that will influence the bonding failure; therefore, the mechanical test results and the micro structure of interface are studied to analyze the quality of interface. The compressive strength of TAICON grows slower than that of conventional concrete in the early age, and then it performs better after long-term test. Further, from the splitting test and ultrasonic pulse velocity, it is found that the more the steel fiber of TAICON is, the better the quality of concrete will be. In other words, the interfacial texture between steel fiber and TAICON concrete can be dense enough to ensure the constraining and bonding ability. The results can be observed from the micro structure before and after interface failure, and the bonding strength of TAICON can be improved.
王家儀. "Evaluating Corrosion Conditions of Steel Bars in Concrete." Thesis, 2012. http://ndltd.ncl.edu.tw/handle/91045757456191305903.
Full text建國科技大學
土木與防災研究所
100
The main purpose of this research is to evaluate corrosion conditions of steel bars in concrete by non-destructive testing, using an electrochemical method able to detect the corrosion potential of steel bars in concrete and concrete current impedance. According to ASTM C876 description, when the corrosion potential measurement values of the steel bar below -350 mV, corrosion may be more than a 90 percent chance. If the concrete current impedance below 10 kΩ-cm, the Steel bar there is the possibility of corrosion. In accordance with the different corrosion factors, the factors of the test planning changes are as follows: concrete containing different concentration of chloride ions, and the steel bar to connect the current to accelerate the corrosion reaction. In addition, plan the use of spraying the solution of chloride ions, the simulation of reinforced concrete structures by sea tidal erosion, the observation of reinforced concrete corrosion process, as the future use of electrochemical detection reference. According to the experimental observations, the concrete containing chloride ions is very easy to cause internal corrosion of the steel bar. In addition, the specimens were placed in a large area of water vapor, water will penetrate through the pores will lead to concrete impedance and corrosion potential decreased, resulting in early damage to reinforced concrete. Current impedance of the concrete can be used as the basis for assessment of concrete internal humidity and moisture content, with the increase in curing time of concrete resistance was correspondingly increased.