Contents
Academic literature on the topic 'Strömungsmessverfahren'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Strömungsmessverfahren.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Dissertations / Theses on the topic "Strömungsmessverfahren"
Fischer, Andreas [Verfasser]. "Messbarkeitsgrenzen optischer Strömungsmessverfahren: Theorie und Anwendungen / Andreas Fischer." Aachen : Shaker, 2013. http://d-nb.info/1048457966/34.
Full textHerzog, Hendrik [Verfasser]. "Entwicklung bionischer Strömungsmessverfahren basierend auf Untersuchungen des Seitenliniensystems der Fische / Hendrik Herzog." Bonn : Universitäts- und Landesbibliothek Bonn, 2016. http://d-nb.info/1107184770/34.
Full textKuschewski, Mario [Verfasser], and Eckart [Akademischer Betreuer] Laurien. "Entwicklung und Anwendung von Strömungsmessverfahren zur Untersuchung wandnaher Temperaturfelder / Mario Kuschewski ; Betreuer: Eckart Laurien." Stuttgart : Universitätsbibliothek der Universität Stuttgart, 2016. http://d-nb.info/1118367928/34.
Full textPutze, Torsten. "Geometrische und stochastische Modelle zur Optimierung der Leistungsfähigkeit des Strömungsmessverfahrens 3D-PTV." Doctoral thesis, Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2009. http://nbn-resolving.de/urn:nbn:de:bsz:14-ds-1231402875520-12137.
Full text3D Particle Tracking Velocimetry (3D PTV) is an image based method for flow field determination. It is based on seeding a flow with tracer particles and recording the flow with a multi camera system. The results are 3D trajectories of a large number of particles for a statistical analysis of the flow. The thesis shows different novel models to increase the spectrum of applications and to optimize efficiency of 3D PTV. Central aspects are the use of the mirror system to generate a virtual multi camera system, the modelling of complex interfaces of multimedia photogrammetry, a probability based tracking method and a novel method for tomographic reconstruction of volume raster data. The improved models are tested in three real testing facilities and with synthetic data. Using a beam splitter in front of the camera lens and deflecting mirrors arranged in the optical path, a four headed virtual camera system can be generated. This method is characterised by its economic efficiency and by the fact that a synchronisation is not necessary. These facts are important especially when using high speed cameras. When observing phenomena in water, there will be refraction at the different interfaces. This has to be taken into account and modelled for each application. Approaches which use correction terms are not suitable to handle complex optical interfaces. The developed approach is based on a multiple refraction ray tracing with known interface parameters and camera orientations. Mostly the multi image matching of particles is performed using epipolar geometry. Caused by the not stable camera orientation or a very high particle density this geometric properties are not sufficient to solve the ambiguities. Using further geometrical radiometrical and physical properties of particles, the determination of the 3D trajectories can be performed. After the analysis of different properties those of them are chosen which are suitable for spatio-temporal matching. 3D PTV bases on the discretisation of particle images in image space and the following object coordinate determination. A raster based approach is the tomographic reconstruction of the volume. Here the light intensity distribution in the volume will be reconstructed. Afterwards the flow information is determined from the differences in successive 3D images. Using tomographic reconstruction techniques a higher particle density can be analysed. The developed approach bases on a slice by slice rectification of the camera images and on a following assembly of the volume. The developed models and approaches are tested at different testing facilities. These differ in size (0.5 dm³ – 20 dm³ – 130 m³) and flow velocities (0.3 m/s – 7 m/s – 0.5 m/s)
Putze, Torsten. "Geometrische und stochastische Modelle zur Optimierung der Leistungsfähigkeit des Strömungsmessverfahrens 3D-PTV." Doctoral thesis, Technische Universität Dresden, 2008. https://tud.qucosa.de/id/qucosa%3A23711.
Full text3D Particle Tracking Velocimetry (3D PTV) is an image based method for flow field determination. It is based on seeding a flow with tracer particles and recording the flow with a multi camera system. The results are 3D trajectories of a large number of particles for a statistical analysis of the flow. The thesis shows different novel models to increase the spectrum of applications and to optimize efficiency of 3D PTV. Central aspects are the use of the mirror system to generate a virtual multi camera system, the modelling of complex interfaces of multimedia photogrammetry, a probability based tracking method and a novel method for tomographic reconstruction of volume raster data. The improved models are tested in three real testing facilities and with synthetic data. Using a beam splitter in front of the camera lens and deflecting mirrors arranged in the optical path, a four headed virtual camera system can be generated. This method is characterised by its economic efficiency and by the fact that a synchronisation is not necessary. These facts are important especially when using high speed cameras. When observing phenomena in water, there will be refraction at the different interfaces. This has to be taken into account and modelled for each application. Approaches which use correction terms are not suitable to handle complex optical interfaces. The developed approach is based on a multiple refraction ray tracing with known interface parameters and camera orientations. Mostly the multi image matching of particles is performed using epipolar geometry. Caused by the not stable camera orientation or a very high particle density this geometric properties are not sufficient to solve the ambiguities. Using further geometrical radiometrical and physical properties of particles, the determination of the 3D trajectories can be performed. After the analysis of different properties those of them are chosen which are suitable for spatio-temporal matching. 3D PTV bases on the discretisation of particle images in image space and the following object coordinate determination. A raster based approach is the tomographic reconstruction of the volume. Here the light intensity distribution in the volume will be reconstructed. Afterwards the flow information is determined from the differences in successive 3D images. Using tomographic reconstruction techniques a higher particle density can be analysed. The developed approach bases on a slice by slice rectification of the camera images and on a following assembly of the volume. The developed models and approaches are tested at different testing facilities. These differ in size (0.5 dm³ – 20 dm³ – 130 m³) and flow velocities (0.3 m/s – 7 m/s – 0.5 m/s).
Putze, Torsten [Verfasser]. "Geometrische und stochastische Modelle zur Optimierung der Leistungsfähigkeit des Strömungsmessverfahrens 3D-PTV / vorgelegt von: Torsten Putze." 2008. http://d-nb.info/992724309/34.
Full text