Academic literature on the topic 'Suspended Insulators'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Suspended Insulators.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Suspended Insulators"

1

Chen, Siyi, and Zhijin Zhang. "Dynamic Pollution Prediction Model of Insulators Based on Atmospheric Environmental Parameters." Energies 13, no. 12 (2020): 3066. http://dx.doi.org/10.3390/en13123066.

Full text
Abstract:
Pollution-induced flashover is one of the most serious power accidents, and the pollution degree of insulators depends on atmospheric environmental parameters. The pollution models used in the power system research are usually static, but the environmental parameters are dynamic. Therefore, the study on the dynamic pollution prediction model is of great importance. In this paper, the dynamic pollution prediction model of insulators based on atmospheric environmental parameters was built, and insulators’ structure coefficients were proposed based on the model. Firstly, the insulator dynamic pol
APA, Harvard, Vancouver, ISO, and other styles
2

Dr., S. K. Mahobia, and G.R.Kumrey Prof. "EXPERIMENTAL STUDY OF SUSPENDED INSULATORS USING OF ALUMINOUS PORCELAIN." International Journal of Engineering Technologies and Management Research 4, no. 10 (2017): 109–13. https://doi.org/10.5281/zenodo.1051007.

Full text
Abstract:
<strong><em>In this paper, we are studying about insulators which are used in transmission line, distribution line, power station. the best performance of the insulator during various load are achieving , the various load such as 500 Watts, 1000Watts 1500Watts, 2000Watts, 2500 watts during time. The insulator are mounted on the upper surface of pin and attached with power supply</em>.</strong>
APA, Harvard, Vancouver, ISO, and other styles
3

Mahobia, S. K., and G. R. Kumrey. "EXPERIMENTAL STUDY OF SUSPENDED INSULATORS USING OF ALUMINOUS PORCELAIN." International Journal of Engineering Technologies and Management Research 4, no. 10 (2020): 109–13. http://dx.doi.org/10.29121/ijetmr.v4.i10.2017.111.

Full text
Abstract:
In this paper, we are studying about insulators which are used in transmission line, distribution line, power station. the best performance of the insulator during various load are achieving , the various load such as 500 Watts, 1000Watts 1500Watts, 2000Watts, 2500 watts during time. The insulator are mounted on the upper surface of pin and attached with power supply.
APA, Harvard, Vancouver, ISO, and other styles
4

Zaripov, D. K., R. A. Nasibullin, D. F. Zakirov, and A. V. Zakharov. "Study of operation of a polymer insulator under uniform and non-uniform contamination." Power engineering: research, equipment, technology 25, no. 5 (2024): 20–29. http://dx.doi.org/10.30724/1998-9903-2023-25-5-20-29.

Full text
Abstract:
RELEVANCE. Suspended insulators, the technical condition of which largely determines the reliability of power supply to consumers of different categories, are one of the most damaged elements of overhead power transmission lines [1-2]. This is primarily due to the fact that during their operation, insulators are exposed to various climatic conditions that have a direct impact on their insulating properties. Moreover, precipitation, such as rain, fog or dew, has the greatest impact precisely in combination with various solid, liquid and gaseous particles deposited on the insulator surface from
APA, Harvard, Vancouver, ISO, and other styles
5

Andreenkov, Evgheny, and Sergey Shunaev. "Capacitive Sensor for Monitoring the Condition of Suspended High-Voltage Insulation." Problems of the Regional Energetics, no. 1(61) (March 2024): 66–74. http://dx.doi.org/10.52254/1857-0070.2024.1-61.06.

Full text
Abstract:
The purpose of the work is to develop the design of a sensor for monitoring the condition of high-voltage power lines suspended insulation. To achieve this goal, a diagnostic criterion was selected, the operating principle and design of the insulation monitoring sensor were determined. As a diagnostic criterion is considered a changing of voltage on the insulator plate due to a change in the distribution of electrical potential on the insulators, caused of damage in the insulators string. For the diagnostic system implementation was adopted a sensor based on a capacitive divider. The calculati
APA, Harvard, Vancouver, ISO, and other styles
6

Huang, Hai, Xun Zhang, Jun Wu, Yi Shi, Baisong Li, and Xiaohua Liu. "Discharge Severity Identification of Suspended Insulators Based on Improved SSD Algorithm." Journal of Physics: Conference Series 3012, no. 1 (2025): 012018. https://doi.org/10.1088/1742-6596/3012/1/012018.

Full text
Abstract:
Abstract In order to realize the intelligent evaluation of UV solar-blind imaging of pollution discharge of suspended insulators based on edge detection, this paper establishes a test platform for pollution discharge of suspended insulators, defines UV parameters such as relative spot area, proposes a criterion for discharge severity, and establishes a database of UV images of different discharges. The improved SSD model is used to train the model, which realizes the reduction of model parameters and the improvement of training convergence speed. The results show that the model file size of th
APA, Harvard, Vancouver, ISO, and other styles
7

Liao, Yifan, Qiao Wang, Lin Yang, Zhiqiang Kuang, Yanpeng Hao, and Chuyan Zhang. "Discharge Behavior and Morphological Characteristics of Suspended Water-Drop on Shed Edge during Rain Flashover of Polluted Large-Diameter Post Insulator." Energies 14, no. 6 (2021): 1652. http://dx.doi.org/10.3390/en14061652.

Full text
Abstract:
Rain is one of the dominant meteorological factors threatening the outdoor insulation performance of ultra-high voltage (UHV) power stations. Discharge occurring on the polluted surface of post insulators in rain has always been a major concern of power stations. Previous studies have shown that suspended water droplets on the shed edge play an important role in the rain flashover process. In this work, artificial contamination rain flashover tests were carried out in a laboratory on a UHV DC (Ultra-High Voltage Direct Current) large-diameter composite post insulator, which had a rod diameter
APA, Harvard, Vancouver, ISO, and other styles
8

Zhang, Zhijin, Siyi Chen, Xingliang Jiang, Jianlin Hu, and Qin Hu. "Analysis of Natural Pollution Accumulation Characteristics of Insulators for Railroads in High-Altitude Environment." Energies 16, no. 15 (2023): 5738. http://dx.doi.org/10.3390/en16155738.

Full text
Abstract:
Railway system insulators are affected by pollution, altitude, and other environmental situations during operation, which causes reduced electrical performance or even flashover accidents. These factors threaten the safety of railway operations in high-altitude areas. However, the natural contamination characteristics of a railroad in a plateau area is still unclear. In this study, a natural pollution accumulation test for railway insulators in a high-altitude area was carried out, and the distribution rules of nonsoluble deposit density (NSDD), equivalent salt deposit density (ESDD), NSDD/ESD
APA, Harvard, Vancouver, ISO, and other styles
9

Andreenkov, Evgeniy S., Vaclav E. Skorubskiy, and Sergey A. Shunaev. "On the issue of modeling a high-voltage insulator in the COMSOL Multiphysics 5.6 soft package." Journal Of Applied Informatics 16, no. 95 (2021): 126–35. http://dx.doi.org/10.37791/2687-0649-2021-16-5-126-135.

Full text
Abstract:
The article discusses the main aspects of modeling suspended polymer high-voltage insulation of overhead power lines (PTL) in the COMSOL Multiphysics 5.6 software package. Analytical expressions of the mathematical model of the electromagnetic field around the insulator are given, on the basis of which a numerical solution is formed within the software package that allows you to build a model of the electric field in two-dimensional and three-dimensional space. There are three main stages of working with the program interface. At the first stage, the task of the geometric dimensions of the mod
APA, Harvard, Vancouver, ISO, and other styles
10

Zhou, Quan, Yongheng Mao, Zhongkai Yin, Chang He, and Ting Yang. "A Seismic Response and AdaBoost Regressor-Based Vulnerability Analysis of an ±800 kV Suspended Filter Capacitor." Applied Sciences 15, no. 6 (2025): 3314. https://doi.org/10.3390/app15063314.

Full text
Abstract:
Existing seismic evaluations of electrical equipment in substations mainly focus on post-type equipment, with few studies addressing the suspended equipment that exhibits significant geometric nonlinearity. Most of the vulnerability analyses on substation equipment consider only ground motion uncertainty, not processing other uncertainties including material properties. Thus, this paper investigates the seismic responses of an ±800 kV suspended filter capacitor using a simulation model. A new approach for vulnerability assessment based on an adaptive boosting (AdaBoost) regressor is proposed c
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Suspended Insulators"

1

United States. National Aeronautics and Space Administration., ed. Damping and scattering of electromagnetic waves by small ferrite spheres suspended in an insulator. National Aeronautics and Space Administration, 1992.

Find full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Suspended Insulators"

1

Chen, Bo, Jiankun Zhao, Baofeng Yan, Wenping Dou, and Fanghui Yin. "Simulation Calculation Analysis of Mechanical Properties of Disc-Shaped Suspended Porcelain Insulators Under Knocking Conditions." In Lecture Notes in Electrical Engineering. Springer Nature Singapore, 2024. https://doi.org/10.1007/978-981-97-8816-3_76.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Suspended Insulators"

1

Ye, Kaixuan, Yisbel E. Marin, Matteo Cherchi, Timo Aalto, and David Marpaung. "Stimulated Brillouin scattering in a 3 µm thick non-suspended silicon platform." In CLEO: Science and Innovations. Optica Publishing Group, 2024. http://dx.doi.org/10.1364/cleo_si.2024.sth4c.6.

Full text
Abstract:
We report the first stimulated Brillouin scattering signal from the 3 µm thick low-loss silicon-on-insulator waveguide platform. The Brillouin gain coefficient is 2.5 m–1W–1 and 1.9 m–1W–1 at 37.6 GHz for the rib and strip waveguides, respectively.
APA, Harvard, Vancouver, ISO, and other styles
2

Luo, Haojun, Chunfeng Jin, Chao Shen, and Jie Yu. "Development status of zero-value detection technology for disk-type suspended insulator string of transmission line." In Ninth International Conference on Energy System, Electricity and Power (ESEP 2024), edited by Mohan Lal Kolhe, Yunfei Mu, Ze Cheng, and Qian Xiao. SPIE, 2025. https://doi.org/10.1117/12.3060100.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Alles, J., A. Beroual, J.-M. George, and E. Brocard. "Evaluation of electrical performance on high voltage glass suspended insulators." In 2017 IEEE Electrical Insulation Conference (EIC). IEEE, 2017. http://dx.doi.org/10.1109/eic.2017.8004688.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Bi, Maoqiang, Jianlin Hu, Tianyan Jiang, Xi Chen, and You Wang. "Study on the Influence of slight looseness of steel foot on performance of suspended porcelain insulators." In 2018 IEEE International Conference on High Voltage Engineering and Application (ICHVE). IEEE, 2018. http://dx.doi.org/10.1109/ichve.2018.8642247.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

White, Paul F., Gerti Kola, Ash Siddiq, and Alan Ng. "OCS Rehabilitation and Kevlar Contact Wire Fall Prevention VTA San Jose, CA." In 2021 Joint Rail Conference. American Society of Mechanical Engineers, 2021. http://dx.doi.org/10.1115/jrc2021-58229.

Full text
Abstract:
Abstract Santa Clara Valley Transportation Authority (VTA) required their original overhead contact system (OCS) along North 1st Street between interstate highway I-880 and West San Carlos Street at the Guadalupe River (opened in 1987) to be rehabilitated. HNTB was chosen to assist with the project and the first task included an overall inspection of the line to ascertain condition, operational deficiencies, and safety concerns. From this inspection, VTA prepared a scope of work for HNTB to perform and then prepare design documents for contractor bidding. During the inspection process, VTA fur
APA, Harvard, Vancouver, ISO, and other styles
6

Martinez, Linnell, and Michal Lipson. "Suspended Silicon-On-Insulator ring resonators." In 2006 Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference. IEEE, 2006. http://dx.doi.org/10.1109/cleo.2006.4628162.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Cheng, Zhenzhou, Xia Chen, C. Y. Wong, et al. "Mid-infrared suspended membrane waveguides on silicon-on-insulator." In 2012 Opto-Electronics and Communications Conference (OECC). IEEE, 2012. http://dx.doi.org/10.1109/oecc.2012.6276468.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Englert, G. W. "Damping of electromagnetic waves by small spheres suspended in an insulator." In International Symposium on Antennas and Propagation Society, Merging Technologies for the 90's. IEEE, 1990. http://dx.doi.org/10.1109/aps.1990.115297.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Andre, N., G. Li, P. Gerard, et al. "Wide band study of silicon-on-insulator photodiodes on suspended micro-hotplates platforms." In 2015 International Conference on IC Design & Technology (ICICDT). IEEE, 2015. http://dx.doi.org/10.1109/icicdt.2015.7165879.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Alaie, Seyedhamidreza, Drew F. Goettler, Khawar Abbas, Ihab El-Kady, and Zayd C. Leseman. "Measurement of In-Plane Thermal Conductivity Using Suspended SiNx Islands." In ASME 2012 International Mechanical Engineering Congress and Exposition. American Society of Mechanical Engineers, 2012. http://dx.doi.org/10.1115/imece2012-88786.

Full text
Abstract:
In order to measure in-plane thermal conductivity, electrical resistivity, and Seebeck Coefficient of Phononic Crystals (PnCs) a micro device is designed and fabricated to host different nano-scale samples. The device is comprised of two SiNx suspended membranes with patterned by Pt on top and covered by AlN. The Pt deposited on these two membranes or islands are dual-purpose temperature sensors and heaters. One side of a sample can be attached to each of the two islands. In this way 1-D heat flow can be established in the material to be tested. Covering the islands with AlN enhances the unifo
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!