Academic literature on the topic 'Synchronous Reference Frame'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Synchronous Reference Frame.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Synchronous Reference Frame"

1

Chapman, P. L., and S. D. Sudhoff. "A multiple reference frame synchronous estimator/regulator." IEEE Transactions on Energy Conversion 15, no. 2 (2000): 197–202. http://dx.doi.org/10.1109/60.867000.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Golestan, Saeed, Josep M. Guerrero, Abdullah M. Abusorrah, and Yusuf Al-Turki. "Hybrid Synchronous/Stationary Reference-Frame-Filtering-Based PLL." IEEE Transactions on Industrial Electronics 62, no. 8 (2015): 5018–22. http://dx.doi.org/10.1109/tie.2015.2393835.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Khatsymovsky, V. M. "On the Kerr metric in a synchronous reference frame." International Journal of Modern Physics D 30, no. 10 (2021): 2150071. http://dx.doi.org/10.1142/s0218271821500711.

Full text
Abstract:
The Kerr metric is considered in a synchronous frame of reference obtained by using proper time and initial conditions for particles that freely move along a certain set of trajectories as coordinates. Modifying these coordinates in a certain way (keeping their interpretation as initial values at large distances), we still have a synchronous frame and the direct analogue of the Lemaitre metric, the singularities of which are exhausted by the physical Kerr singularity (the singularity ring).
APA, Harvard, Vancouver, ISO, and other styles
4

Pan, Rongcai, and Peide Sun. "Multifunctional inverter based on virtual synchronous machine implemented in synchronous reference frame." Electrical Engineering 103, no. 4 (2021): 2093–111. http://dx.doi.org/10.1007/s00202-021-01220-w.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Popovici, Alexandru-Tudor, and Alexandru Onea. "Generalized Differential Mathematical Model in Stator Reference Frame for PMSM and VRSM Simulation." Bulletin of the Polytechnic Institute of Iași. Electrical Engineering, Power Engineering, Electronics Section 67, no. 4 (2021): 43–55. http://dx.doi.org/10.2478/bipie-2021-0021.

Full text
Abstract:
Abstract The paper presents the deduction of a novel decoupled form (considering the differential current quantities) of the differential mathematical model in stator reference frame, useful for numeric simulation of control approaches for PMSM (permanent magnet synchronous machines) generalized for both IPMSM and SPMSM (salient and non-salient PMSM). The model is confirmed to be equivalent to the well-known model defined in the rotor synchronous reference frame using a Matlab-Simulink implementation that is verified and validated by simulation during which the power/energy conservation is mon
APA, Harvard, Vancouver, ISO, and other styles
6

Subash Kumar, C. S., and V. Gopalakrishnan. "Modified Synchronous Reference Frame Based Harmonic Extraction for Shunt Active Filter." International Journal of Power Electronics and Drive Systems (IJPEDS) 6, no. 4 (2015): 897. http://dx.doi.org/10.11591/ijpeds.v6.i4.pp897-905.

Full text
Abstract:
<p>This paper presents the modified synchronous reference frame based Shunt Active Filter (SAF) for the instantaneous compensation of harmonic current present at the Point of Common Coupling. The harmonics generated by the non linear load are extracted using the positive frame and negative frame of the input signal using the modified synchronous reference frame theory with extended Multiple Reference Frame based PLL (EMRFPLL). Based on the harmonics extracted, pulse width modulation signals are generated using Artificial Neural Network based Space Vector Pulse width Modulation technique
APA, Harvard, Vancouver, ISO, and other styles
7

Svishch, V. M. "The Features of the Reference Frame Concomitant to the Cosmic Microwave Background." European Journal of Applied Physics 3, no. 6 (2021): 1–6. http://dx.doi.org/10.24018/ejphysics.2021.3.6.115.

Full text
Abstract:
The features of reference frame, concomitant to the cosmic microwave background, immobile relatively cosmic microwave background, are considered. It is shown that the features of reference frame, concomitant to the cosmic microwave background (CMB), are determined by its properties. Any other object in the Universe and reference frame concomitant to it, is immersed in the CMB and moves relative to the reference frame concomitant to microwave background radiation. The zero pecular velocity of the reference frame concomitant to the microwave background radiation is analogous to the zero temperat
APA, Harvard, Vancouver, ISO, and other styles
8

Li, Dan, and Ting Ting Cai. "Control Strategy for VSC-HVDC under Unbalanced Grid Voltages." Applied Mechanics and Materials 863 (February 2017): 214–19. http://dx.doi.org/10.4028/www.scientific.net/amm.863.214.

Full text
Abstract:
This paper describes the use of an unbalanced control strategy to solve the faults occur in AC grid side of High voltage direct current based on Voltage Source Converter (VSC-HVDC) system. This method divides the voltage and current parameters into negative-sequence and positive-sequence. It can be obtained that the negative-sequence appears as double-frequency component in the positive-sequence synchronous reference frame; while, it appears as dc component in the negative-sequence synchronous reference frame. To mitigate the unfavourable impact of the unbalance fault, such as the DC link ripp
APA, Harvard, Vancouver, ISO, and other styles
9

Zsigmond, Andor-Attila, and András Kelemen. "Implementation of Grid Synchronization Methods on a Real Time Development System." Acta Universitatis Sapientiae, Electrical and Mechanical Engineering 13, no. 1 (2021): 52–67. http://dx.doi.org/10.2478/auseme-2021-0005.

Full text
Abstract:
Abstract The paper presents a study regarding the implementation of two representative grid synchronization methods, intended to be used in the control structure of a three phase switch mode voltage rectifier. The methods considered are the Synchronous Reference Frame Phase Locked Loop (SRF PLL) and the Double Synchronous Frame Phase Locked Loop (DSRF PLL), respectively. These synchronization methods have been compared on a real time development system type dSpace 1104 from the point of view of their performance in case of an unbalanced mains voltage system. Finally, the influence of the chose
APA, Harvard, Vancouver, ISO, and other styles
10

CIANFRANI, FRANCESCO, and GIOVANNI MONTANI. "SYNCHRONOUS QUANTUM GRAVITY." International Journal of Modern Physics A 23, no. 08 (2008): 1149–56. http://dx.doi.org/10.1142/s0217751x08040007.

Full text
Abstract:
The implications of restricting the covariance principle within a Gaussian gauge are developed both on a classical and a quantum level. Hence, we investigate the cosmological issues of the obtained Schrödinger Quantum Gravity with respect to the asymptotically early dynamics of a generic Universe. A dualism between time and the reference frame fixing is then inferred.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Synchronous Reference Frame"

1

Felicetti, Roberto. "Field Current Control for the Damping of Rotor Oscillations and for the Alternative Start of Synchronous Machines : Further Innovative Applications of Field Current Active Control besides UMP-Compensation." Thesis, Uppsala universitet, Institutionen för teknikvetenskaper, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-353669.

Full text
Abstract:
The possibility to save energy in synchronous machines operation by dismissing d-axis damping bars and surrogating them with active excitation current control in sectored field winding is proved. In particular a way to recover the energy of rotor oscillations during power regulation is shown by means of a studycase generator whereas a self-starting machine is analytically and numerically designed in view of its next construction and test. Principal design requirements and limits for both applications are presented and discussed.
APA, Harvard, Vancouver, ISO, and other styles
2

Dušek, Jiří. "Řízení stroje s PM v d-q osách při použití Matlab/Simulink." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2010. http://www.nusl.cz/ntk/nusl-218789.

Full text
Abstract:
Tato práce se zabývá synchronním motorem s permanentními magnety na rotoru (PMSM), jeho modelováním a návrhu regulační struktury. V práci jsou uvedeny způsoby a výhody použití permanentních magnetů v elektrických motorech. Dále se práce zabývá transformací třífázové soustavy do dq0. Pomocí Parkovy transformace jsou v práci odvozeny rovnice stroje v dq0 souřadnicovém systému a vytvořeny náhradní schémata stroje v dq osách. Rovnice i schémata zahrnují jak ztráty v mědi, tak ztráty v železe. Náhradní schémata jsou popsány elektrickými a mechanickými rovnicemi a následně překresleny do grafické po
APA, Harvard, Vancouver, ISO, and other styles
3

Sagha, Hossein. "Development of innovative robust stability enhancement algorithms for distribution systems containing distributed generators." Thesis, Queensland University of Technology, 2015. https://eprints.qut.edu.au/91052/1/Hossein_Sagha_Thesis.pdf.

Full text
Abstract:
This project was a step forward in improving the voltage profile of traditional low voltage distribution networks with high photovoltaic generation or high peak demand. As a practical and economical solution, the developed methods use a Dynamic Voltage Restorer or DVR, which is a series voltage compensator, for continuous and communication-less power quality enhancement. The placement of DVR in the network is optimised in order to minimise its power rating and cost. In addition, new approaches were developed for grid synchronisation and control of DVR which are integrated with the voltage qual
APA, Harvard, Vancouver, ISO, and other styles
4

Barden, Alisson Thomas. "Projeto e análise de controladores robustos aplicados a inversores trifásicos de fontes ininterruptas de energia (UPS)." reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, 2016. http://hdl.handle.net/10183/141945.

Full text
Abstract:
O objetivo principal deste trabalho é o desenvolvimento de controladores robustos baseados no princípio do modelo interno, em referenciais síncrono e estacionário, para aplicação ao estágio de saída de uma fonte ininterrupta de energia (UPS) a fim de minimizar a distorção na tensão de saída causada pela conexão de cargas não lineares balanceadas e desbalanceadas. A formulação em referencial estacionário (abc) é realizada através da aplicação de controladores com múltiplos modos ressonantes, a fim de se estabelecer erro nulo ao seguimento de referência senoidal e rejeição de distúrbios na tensã
APA, Harvard, Vancouver, ISO, and other styles
5

Teng, Chao-Hsi, and 滕肇熙. "The Implementation of a Vector-Controlled Induction Motor Drive in the Synchronous Reference Frame." Thesis, 1994. http://ndltd.ncl.edu.tw/handle/48452011961818856402.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>電機工程研究所<br>82<br>In this paper, a vector-controlled induction motor drive is implemented in the synchronous reference frame. The principle of field orientation is employed in a speed-controlled application. This algorithm provides a dynamic decoupling of a fourth-order dynamic system of the induction motor and reduces it to a first-order one in the synchronous reference frame. And the voltage space vector modulation method is also employed in this paper. In the hardware st
APA, Harvard, Vancouver, ISO, and other styles
6

Eren, Suzan. "Modifying the Three-Phase Synchronous Reference Frame Phase-Locked Loop to Remove Unbalance and Harmonic Errors." Thesis, 2008. http://hdl.handle.net/1974/1635.

Full text
Abstract:
As an increasing number of distributed power generation systems (DPGS) are being connected to the utility grid, there is a growing requirement for the DPGS to be able to ride through short grid disturbances. This requires improvements to be made to the grid-side control scheme of the DPGS. An important part of the grid-side control scheme is the grid synchronization method, which is responsible for tracking the phase angle of the grid voltage vector. The state-of-the-art grid synchronization methods being used today are phase-locked loops. This thesis presents a modified phase-locked loop wh
APA, Harvard, Vancouver, ISO, and other styles
7

Abhijit, K. "Design And Control of Power Converters for Renewable Energy Systems." Thesis, 2016. http://etd.iisc.ac.in/handle/2005/2663.

Full text
Abstract:
Renewable energy sources normally require power converters to convert their energy into standardized regulated ac output. The motivation for this thesis is to design and control power converters for renewable energy systems to ensure very good power quality, efficiency and reliability. The renewable energy sources considered are low voltage dc sources such as photovoltaic (PV) modules. Two transformer-isolated power circuit topologies with input voltage of less than 50V are designed and developed for low and medium power applications. Various design and control
APA, Harvard, Vancouver, ISO, and other styles
8

Abhijit, K. "Design And Control of Power Converters for Renewable Energy Systems." Thesis, 2016. http://etd.iisc.ernet.in/handle/2005/2663.

Full text
Abstract:
Renewable energy sources normally require power converters to convert their energy into standardized regulated ac output. The motivation for this thesis is to design and control power converters for renewable energy systems to ensure very good power quality, efficiency and reliability. The renewable energy sources considered are low voltage dc sources such as photovoltaic (PV) modules. Two transformer-isolated power circuit topologies with input voltage of less than 50V are designed and developed for low and medium power applications. Various design and control
APA, Harvard, Vancouver, ISO, and other styles
9

ZHENG, FU-SHENG, and 鄭富升. "Dynamic analysis of a slip energy recovery system based on synchronously rotating reference frame." Thesis, 1990. http://ndltd.ncl.edu.tw/handle/36613700301203114472.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Books on the topic "Synchronous Reference Frame"

1

Vaez-Zadeh, Sadegh. Machine Modeling. Oxford University Press, 2018. http://dx.doi.org/10.1093/oso/9780198742968.003.0002.

Full text
Abstract:
This chapter presents dynamic and steady-state modeling of permanent magnet synchronous (PMS) machines with the help of reference frames. The modeling starts with a machine model in terms of phase variables. An equivalent two-axis model in a stationary reference is then obtained by a reference frame transformation. A further transformation to a two-axis rotor reference frame, with its direct axis aligned with the axis of a permanent magnet rotor pole, is derived. Another transformation to a two-axis stator flux linkage reference frame is also presented. Finally, a motor model in polar coordina
APA, Harvard, Vancouver, ISO, and other styles
2

Vaez-Zadeh, Sadegh. Control of Permanent Magnet Synchronous Motors. Oxford University Press, 2018. http://dx.doi.org/10.1093/oso/9780198742968.001.0001.

Full text
Abstract:
This is the first comprehensive, coherent, and up-to-date book devoted solely to the control of permanent magnet synchronous (PMS) motors, as the fastest growing AC motor. It covers a deep and detailed presentation of major PMS motor modeling and control methods. The readers can find rich materials on the fundamentals of PMS motor control in addition to new motor control methods, which have mainly been developed in the last two decades, including recent advancements in the field in a systematic manner. These include extensive modeling of PMS motors and a full range of vector control and direct
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Synchronous Reference Frame"

1

Ruan, Xinbo, Xuehua Wang, Donghua Pan, Dongsheng Yang, Weiwei Li, and Chenlei Bao. "Prefilter-Based Synchronous Reference Frame Phase-Locked Loop Techniques." In CPSS Power Electronics Series. Springer Singapore, 2017. http://dx.doi.org/10.1007/978-981-10-4277-5_12.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Manohara, M., T. Nageswara Prasad, D. Leela Rani, et al. "Solar grid power quality improvement with synchronous reference frame filters." In Challenges in Information, Communication and Computing Technology. CRC Press, 2024. http://dx.doi.org/10.1201/9781003559092-68.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Rini Ann Jerin, A., K. Palanisamy, S. Umashankar, and Padmanaban Sanjeevikumar. "Comparative Analysis of Feed-Forward and Synchronous Reference Frame Control-Based Dynamic Voltage Restorer." In Advances in Power Systems and Energy Management. Springer Singapore, 2017. http://dx.doi.org/10.1007/978-981-10-4394-9_41.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Sridharan, K., B. Chitti Babu, B. Naga Parvathi, and P. Kartheek. "Pre-filters Based Synchronous Rotating Reference Frame Phase Locked Loop (SRF PLL) Design for Distorted Grid Conditions." In Advances in Intelligent Systems and Computing. Springer Singapore, 2017. http://dx.doi.org/10.1007/978-981-10-3174-8_16.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Prasad, Dinanath, Narendra Kumar, and Rakhi Sharma. "Shunt Active Power Filter Based on Synchronous Reference Frame Theory Connected to SPV for Power Quality Enrichment." In Lecture Notes in Electrical Engineering. Springer Singapore, 2021. http://dx.doi.org/10.1007/978-981-16-2354-7_26.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Vijayakumari, A., A. T. Devarajan, and N. Devarajan. "Effect of Grid Impedance Variation on the Control of Grid Connected Converters with Synchronous Reference Frame Controllers in Micro-Grids." In Lecture Notes in Electrical Engineering. Springer India, 2014. http://dx.doi.org/10.1007/978-81-322-2119-7_126.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Kabat, Subash Ranjan, Chinmoy Kumar Panigrahi, and Bibhu Prasad Ganthia. "Comparative Analysis of Fuzzy Logic and Synchronous Reference Frame Controlled LVRT Capability Enhancement in Wind Energy System Using DVR and STATCOM." In Advances in Sustainability Science and Technology. Springer Singapore, 2022. http://dx.doi.org/10.1007/978-981-16-9033-4_32.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Rajak, Mrinal Kanti, and Rajen Pudur. "Hardware-In-The-Loop Simulation Approach for Grid Integration of a 2.2 kW Self-Excited Induction Generator Using Synchronous Reference Frame Theory." In Energy, Environment, and Sustainability. Springer Nature Singapore, 2024. http://dx.doi.org/10.1007/978-981-97-1406-3_14.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Lipo, T. A. "Reference Frame Theory." In Analysis of Synchronous Machines. CRC Press, 2017. http://dx.doi.org/10.1201/b12211-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

"Synchronous Reference Frame PLL." In Enhanced Phase-Locked Loop Structures for Power and Energy Applications. John Wiley & Sons, Inc, 2014. http://dx.doi.org/10.1002/9781118795187.ch6.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Synchronous Reference Frame"

1

Chitpadi, Nagesha, and Lakshminarasamma N. "LCLC Resonant Converter Modelling in Synchronous Reference Frame." In 2024 IEEE Kansas Power and Energy Conference (KPEC). IEEE, 2024. http://dx.doi.org/10.1109/kpec61529.2024.10676302.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Zhao, Yichen, and Yongming Zhang. "Study of Improved Decoupled Double Synchronous Reference Frame Phase-Locked Loop." In 2024 5th International Conference on Smart Grid and Energy Engineering (SGEE). IEEE, 2024. https://doi.org/10.1109/sgee64306.2024.10865888.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Mousavi, Mohammad Hossein, Mojtaba Ahmadi, and Hassan Moradi. "Decoupled Double Synchronous Reference Frame Sequence Extraction Technique: A Compact Review on Applications in Microgrids." In 2024 9th International Conference on Technology and Energy Management (ICTEM). IEEE, 2024. http://dx.doi.org/10.1109/ictem60690.2024.10631965.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Gonzatti, R. B., Carlos H. da Silva, E. M. Vaciloto, S. C. Ferreira, L. E. Borges da Silva, and G. Lambert-Torres. "STATCOM based on Modified Synchronous Reference Frame." In 2013 Brazilian Power Electronics Conference (COBEP 2013). IEEE, 2013. http://dx.doi.org/10.1109/cobep.2013.6785269.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

He, Xiaoyang, Miao Liu, Yunlu Li, Feng Hong, Junyou Yang, and Feng Jiang. "Synchronous Reference Frame Paralleled MAF/DSC-Based PLL." In 2020 Asia Energy and Electrical Engineering Symposium (AEEES). IEEE, 2020. http://dx.doi.org/10.1109/aeees48850.2020.9121525.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Stojic, Djordje, Slavko Veinovic, and Milan Milinkovic. "Modified Synchronous Reference Frame Based Hysteresis Current Controller." In 2019 20th International Symposium on Power Electronics (Ee). IEEE, 2019. http://dx.doi.org/10.1109/pee.2019.8923322.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Mazumdar, Joy, Ronald G. Harley, and Ganesh K. Venayagamoorthy. "Synchronous Reference Frame Based Active Filter Current Reference Generation Using Neural Networks." In IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics. IEEE, 2006. http://dx.doi.org/10.1109/iecon.2006.348114.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Marques, G. D., V. Fernao Pires, Mariusz Malinowski, and Marian Kazmierkowski. "An Improved Synchronous Reference Frame Method for Active Filters." In EUROCON 2007 - The International Conference on "Computer as a Tool". IEEE, 2007. http://dx.doi.org/10.1109/eurcon.2007.4400408.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Kim, Junwoo, Sungyoon Jung, and Kwanghee Nam. "Dynamic overmodulation in the synchronous reference frame for IPMSMs." In 2012 IEEE Energy Conversion Congress and Exposition (ECCE). IEEE, 2012. http://dx.doi.org/10.1109/ecce.2012.6342735.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Sheikh, Ahmed, Tarek Youssef, and Osama Mohammed. "AC Microgrid Control Using Adaptive Synchronous Reference Frame PLL." In 2017 Ninth Annual IEEE Green Technologies Conference (GreenTech). IEEE, 2017. http://dx.doi.org/10.1109/greentech.2017.13.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Synchronous Reference Frame"

1

APPLICATION OF HYDRAULIC SYNCHRONOUS LIFTING TECHNOLOGY IN THE CONSTRUCTION OF LONG-SPAN HYBRID STEEL STRUCTURES. The Hong Kong Institute of Steel Construction, 2022. http://dx.doi.org/10.18057/icass2020.p.070.

Full text
Abstract:
The aim of this study was to solve technical problems, such as uneven structures, multiple lifting points, high accuracy control requirements, and multi-disciplinary collaborative work, in the process of lifting and hoisting long-span hybrid steel structures based on the lifting work of a steel roof and steel beams of the Hunan Radio and Television studio F. First, after conducting research on the comparison and selection of the construction scheme, lifting process, quality control and other aspects, a floor assembly + hydraulic lifting + overhead supplementary bar construction plan was propos
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!