Dissertations / Theses on the topic 'Termický systém'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Termický systém.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Jelínek, Petr. "Využití referenčního klimatického roku pro hodnocení a návrh termického solárního systému." Doctoral thesis, Vysoké učení technické v Brně. Fakulta stavební, 2019. http://www.nusl.cz/ntk/nusl-408022.
Full textKrňávek, Martin. "Regionální energetické využití odpadů." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2015. http://www.nusl.cz/ntk/nusl-231798.
Full textMikšík, František. "Stárnutí teplonosných kapalin v termických solárních systémech a propan-1,3-diol jako nová možnost." Doctoral thesis, Vysoké učení technické v Brně. Fakulta chemická, 2018. http://www.nusl.cz/ntk/nusl-385285.
Full textŠevčíková, Kateřina. "Zpracování projektu fotovoltaického systému." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2011. http://www.nusl.cz/ntk/nusl-216786.
Full textHrazdira, David. "Energetický audit." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2018. http://www.nusl.cz/ntk/nusl-372193.
Full textKohont, Alexander, and Roger Can Isik. "TERMISKT SMARTA HANTERINGSSYSTEM FÖR LITIUMJONBATTERIER : Analys av litium-jonbatteriets termiska beteende." Thesis, Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-55065.
Full textHorský, Martin. "Termické solární systémy." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2014. http://www.nusl.cz/ntk/nusl-226842.
Full textPutna, Ondřej. "Termické zpracování odpadů jako klíčový prvek efektivních systémů odpadového hospodářství." Doctoral thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2020. http://www.nusl.cz/ntk/nusl-433521.
Full textLainka, Pavel. "Využití termických panelů pro zvýšení účinnosti chladiciho okruhu TČ." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2016. http://www.nusl.cz/ntk/nusl-254311.
Full textHosová, Žaneta. "Vliv malých domácích spotřebičů na ekonomiku kombinovaných systémů." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2013. http://www.nusl.cz/ntk/nusl-216939.
Full textOhlsson, Pontus. "Termisk lagring vid Akademiska sjukhuset : Kapning av effekttoppar, ökad redundans och energisäkerhet." Thesis, Uppsala universitet, Fasta tillståndets fysik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-348020.
Full textHaglund, Mikael. "Kylbehovet hos ett batteribaserat elenergilager : Med avseende på kyldistribution, drifttemperatur, klimat, isolering och termisk tröghet." Thesis, Karlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013), 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-28650.
Full textIn 2011 MacBat AB began to develop a electrical energy storage system called Macbat Energy Storage System (MESS), which is made up of 360 two volt lead acid batteries housed in a 20 foot container. However, while lead acid batteries are sensitive to heat this study is focused on investigating how great a cooling demand will be required under different conditions in which chilled distribution, operating temperature of the batteries, climate, insulation and thermal inertia are varied parameters. The study will also determine the configuration of chilled distribution and isolation that gives minimum cooling requirements for the studied climates, which is warm temperate, arid and tropical nature To answer the study's two goals four mathematical models were developed in SIMULINK. Two air-cooled and two water-cooled where one of each was insulated with 100 mm mineral wool while the other was bare. For all models the operating temperature varied between 25 - 35 ° C and the studied climates consisted of Phnom Penh, Cambodia, Djibouti, Djibouti, Baghdad, Iraq, and London, England. For the water cooled models thermal inertia was also varied in the range of 1.8058 to 9.0288 MJ/ K by increasing the amount of cooling water in the system used to cool the batteries. The battery operating temperature was proven to have the most significant impact on the cooling load. The isolation yielded a reducing effect on the cooling load in the case where the ambient temperature surpassed the battery operating temperature during longer periods. Varying thermal inertia of the water cooled models had little or no impact on the cooling load. It is probably due to the electrolyte in the batteries. It is a considerably larger source of thermal mass and is constant in all the models. Which configuration, regarding the distribution system and insulation, that obtains a low cooling requirement was found to depend on the ambient climate and the battery operating temperature. However, warm temperate climates such as London requires no cooling system at all.
Hansson, Kajsa. "Jämförelse av VAV- och CAV-ventilationssystem för nybyggd skola och dess känslighet för ökad personbelastning : En simuleringsstudie med IDA ICE." Thesis, Högskolan i Gävle, Energisystem och byggnadsteknik, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-29750.
Full textTo reduce the energy use is as much a global goal as it is an international goal. The Swedish goal is to increase the efficiency of energy use with 20 % by year 2020. This means that almost all the sectors are affected, that includes the housing and service sector which accounts for almost 40 % of Sweden’s energy use. The ventilation system is one thing that can contribute to saving energy. In this study a new built primary school has been simulated, regarding energy use and thermal comfort, where different ventilation system has been tested to determine which system are the most profitable in economically, energy and comfortably. The ventilation system different in the flow control. Two main types of flow control have been tested: Variable Air Volume (VAV) and Constant Air Volume (CAV). The building, which is well insulated and has a heavy body has also been simulated with increased personal load to see how it affects the ventilation system. The method used to perform the work is a comparative type simulation study. The computer program IDA ICE 4.8 has been used to build the model and do the simulations. The model that has been simulated resemble the primary school Stigslundsskolan in Gävle in both construction, ventilation and degree of use. Data has been collected from the consulting company Ramboll’s database with information on the planning of the school. Personal communication has also been used to collect information. The simulations have been performed for a school year and a schedule for the personal load has been set for each hall to imitate the schedule that the students are following today. The result of the simulations showed that the VAV ventilation system, which resemble the planned case, cover the ventilation requirements, uses less energy than the CAV system and create a very good thermal climate in the building. The result also shows that the increased personal load had a great influence on the VAV ventilation system and increased the repayment period from 11 to 30 years.
NAHUEL, CARDENAS JOSE P. "Monitoracao continua do balanco termico para determinacao da potencia do reator IEA-R1." reponame:Repositório Institucional do IPEN, 2000. http://repositorio.ipen.br:8080/xmlui/handle/123456789/10799.
Full textMade available in DSpace on 2014-10-09T14:07:37Z (GMT). No. of bitstreams: 1 06916.pdf: 11842255 bytes, checksum: 3613e123a5688532ff6194076f7f0e1a (MD5)
Dissertacao (Mestrado)
IPEN/D
Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
Payá, Herrero Jorge. "Modelling and analysis of a metal hydride cooling system." Doctoral thesis, Universitat Politècnica de València, 2010. http://hdl.handle.net/10251/8911.
Full textPayá Herrero, J. (2010). Modelling and analysis of a metal hydride cooling system [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/8911
Palancia
Neradil, Petr. "Analýza reologických vlastností teplonosných kapalin." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2016. http://www.nusl.cz/ntk/nusl-242100.
Full textFlorian, Ondřej. "Příprava a průběh hydratace pojivového systému na bázi stroncium yttritého cementu." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2015. http://www.nusl.cz/ntk/nusl-217146.
Full textVILAFRANCA, MANGUÁN ANA. "Convesion of industrial compression cooling to absorption cooling in an integrated district heating and cooling system." Thesis, University of Gävle, University of Gävle, Department of Technology and Built Environment, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-4145.
Full textAstra Zeneca plant in Gärtuna has many compression cooling machines for comfort that consume about 11.7 GWh of electricity per year. Many of the cooling machines are old; due to the increase of production of the plant, cooling capacity was limited and new machines have been built. Now, the cooling capacity is over-sized. Söderenergi is the district heating plant that supplies heating to Astra Zeneca plant. Due to the strict environmental policy in the energy plant, last year, a bio-fuelled CHP plant was built. It is awarded with the electricity certificate system.
The study investigates the possibility for converting some of the compression cooling to absorption cooling and then analyzes the effects of the district heating system through MODEST optimizations. The effects of the analysis are studied in a system composed by the district heating system in Södertälje and cooling system in Astra Zeneca. In the current system the district heating production is from boiler and compression system supplies cooling to Astra Zeneca. The future system includes a CHP plant for the heating production, and compression system is converted to absorption system in Astra Zeneca. Four effects are analyzed in the system: optimal distribution of the district heating production with the plants available, saving fuel, environmental impact and total cost. The environmental impact has been analyzed considering the marginal electricity from coal condensing plants. The total cost is divided in two parts: production cost, in which district heating cost, purchase of electricity and Emissions Trading cost are included, and investment costs. The progressive changes are introduced in the system as four different scenarios.
The introduction of the absorption machines in the system with the current district heating production increases the total cost due to the low electricity price in Sweden. The introduction of the CHP plant in the district heating production supposes a profit of the production cost with compression system due to the high income of the electricity produced that is sold to the grid; it profit increases when compression is replaced by absorption system. The fuel used in the production of the future system decreases and also the emissions. Then, the future system becomes an opportunity from an environmental and economical point of view. At higher purchase electricity prices predicted in the open electricity market for an immediately future, the future system will become more economically advantageous.
Christopher, Magnusson. "Förbättrat inomhusklimat med lägre energiförbrukning i öppet kontorslandskap : Ventilationens påverkan på inomhusklimatet och termisk komfort." Thesis, Högskolan i Gävle, Avdelningen för byggnadsteknik, energisystem och miljövetenskap, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-30414.
Full textHájovská, Pavla. "Příprava a charakterizace směsných hydrogelů na bázi systému hyaluronan-albumin." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2017. http://www.nusl.cz/ntk/nusl-316178.
Full textLarek, Adrian, and Jimmy Tran. "Inverkan av värmesystem på termisk komfort i ett flerbostadshus med hänsyn till energianvändning." Thesis, KTH, Installations- och energisystem, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-170439.
Full textThe indoor climate plays a crucial role in human health and well-being when people are indoors for nearly half their life. There are several aspects to how one should achieve good indoor climate, but the more significant aspects are both good air quality and thermal comfort. Simultaneously one must regard that the reduction of energy has an important role in today’s development. While trying to reduce energy consumption in order to facilitate the environmental load, it raises the questions whether the thermal comfort is affected by this. The purpose of the report will lie in the identification of a heating system for a given apartment building in the Stockholm area, with a focus on thermal comfort and energy use. The evaluation is based on various types of impacts from various systems that have been computed in IDA ICE. A reference case for an apartment building was used as a basis and was modeled according to architectural and constructional drawings while input data was used according to Sveby. It will also include the environmental certifications used in Sweden and specify their requirements regarding the thermal comfort, and each focus area as various environmental certifications have different assessment criteria’s. During this study it was found that we rarely take into account the thermal comfort in the same way we do with the energy consumption. It has also been found that in cases where the requirements for the thermal comfort exist, it is often insufficiently defined to provide one with a good perception of comfort. The requirements do, in other words, not take into account how well a building performs during a whole year but instead focuses on one instantaneous value. For the simulation a sensitivity analysis was made that revealed the importance and necessity of a clear standard for undefined variables to express the people’s assessment of thermal comfort. After the simulation part, the energy calculations were examined according to a review template from WSP Systems. This provided a basis for fair consideration. From the obtained results it was shown that floor heating and increasing the setpoint to 22 °C gave an increased thermal comfort but at the same time an increase in energy use. An HVAC system with a heat exchanger and radiators resulted in reduced energy use by about a third from the reference case and a slight increase in current thermal comfort. It also proved that the choice of an HVAC system with heat exchanger produced the highest annual energy savings. However one must take into account installation costs for different types of systems as opposed to when the setpoint is increased to 22 °C. Thus it becomes a cost issue and a critical parameter for selecting among these three types of solutions.
TORRES, WALMIR M. "Desenvolvimento de uma tecnica de medida de nivel em vasos de pressao utilizando sondas termicas e redes neurais artificiais." reponame:Repositório Institucional do IPEN, 2008. http://repositorio.ipen.br:8080/xmlui/handle/123456789/11761.
Full textMade available in DSpace on 2014-10-09T14:07:16Z (GMT). No. of bitstreams: 0
Tese (Doutoramento)
IPEN/T
Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
Zálešáková, Romana. "Příprava a charakterizace polymerních kompozitních systémů s přídavkem grafenu." Master's thesis, Vysoké učení technické v Brně. Fakulta chemická, 2018. http://www.nusl.cz/ntk/nusl-438896.
Full textVerde, Trindade María. "MODELLING AND OPTIMIZATION OF AN ADSORPTION COOLING SYSTEM FOR AUTOMOTIVE APPLICATIONS." Doctoral thesis, Universitat Politècnica de València, 2015. http://hdl.handle.net/10251/54120.
Full text[ES] Esta tesis doctoral se centra en el modelado de un sistema de adsorción diseñado para proporcionar aire acondicionado de vehículos a partir del calor residual disponible en el circuito de refrigeración de agua/glicol del motor. El sistema se basa en el calentamiento/enfriamiento secuencial de dos reactores que contienen un material adsorbente sólido que desorbe o absorbe vapor de agua. La condensación del vapor se lleva a cabo mediante un circuito de refrigeración, mientras que la posterior evaporación del agua condensada se emplea para producir agua fría, que se emplea finalmente en enfriar el aire de la cabina. El modelo desarrollado es completamente dinámico y se basa en modelos cero dimensionales de parámetros concentrados, para todos y cada uno de los componentes del sistema global incluyendo el motor, los reactores, el circuito de calentamiento, el circuito de enfriamiento, el circuito de agua fría y la cabina del vehículo. El modelo del reactor contempla el no equilibrio de los procesos de adsorción o desorción y es capaz de trabajar con cualquier par de materiales adsorbentes. No obstante el estudio se ha restringido a gel de sílice y zeolita que se encuentran entre los materiales más adecuados para esta aplicación. El modelo se emplea para simular un ciclo de conducción estándar del vehículo, evaluando el calor disponible instantáneamente en el sistema de refrigeración del motor, y el comportamiento dinámico del sistema descrito adsorción-Aire Acondicionado, permitiendo como resultado principal la estimación de la evolución de la temperatura de la cabina a lo largo el ciclo. El modelo del sistema global se ha desarrollado en el marco del entorno de programación MATLAB Simulink. El modelo del sistema de adsorción se ha validado primero contra resultados experimentales demostrando las excelentes capacidades del modelo para predecir el comportamiento dinámico del sistema. A continuación, el modelo se ha aplicado para analizar la influencia de los principales parámetros de diseño del reactor, y de los principales parámetros de operación, sobre el rendimiento del sistema: la capacidad y coeficiente de operación (COP), con el fin de proporcionar directrices para el diseño y operación óptima de este tipo de sistemas. Por último, el modelo ha sido empleado para analizar el funcionamiento y prestaciones del sistema en su conjunto (motor, sistema de absorción, los circuitos de calefacción y refrigeración, circuito de agua fría, y la cabina) a lo largo de un ciclo de conducción estándar, bajo diferentes estrategias de operación en lo que se refiere al estado inicial del material adsorbente en los reactores, y las condiciones de operación, para el caso de un coche, y para el de un camión. Los resultados muestran las dificultades de la activación del sistema en los periodos iniciales del ciclo, cuando el motor se está calentando, y las dificultades para sincronizar el funcionamiento del sistema con la disponibilidad de energía térmica excedente del motor, así como la limitación en la capacidad de enfriamiento del sistema diseñado, que no resulta capaz de satisfacer los requerimientos mínimos de confort dentro de la cabina en los días calurosos o de enfriarlo con suficiente rapidez cuando el vehículo ha estado estacionado bajo el sol durante varias horas. Parte de este estudio de doctorado se ha llevado a cabo en el marco de un proyecto de I + D denominado " Thermally Operated Mobile Air Conditioning Systems - TOPMACS", financiado parcialmente por la UE en el marco del programa FP6, y que perseguía la evaluación de la viabilidad y el potencial de aplicación de soluciones de sistemas de adsorción activadas por el calor residual del motor para el aire acondicionado de vehículos.
[CAT] Aquesta tesi doctoral es centra en el model d'un sistema d'adsorció dissenyat per a proporcionar aire acondicionat a vehicles a partir de la calor residual disponible al circuit de refrigeració d'aigua / glicol del motor. El sistema es basa en l'escalfament / refredament seqüencial de dos reactors que contenen un material adsorbent sòlid que desorbeix o absorbeix vapor d'aigua. La condensació del vapor es porta a terme mitjançant un circuit de refrigeració, mentre que la posterior evaporació de l'aigua condensada s'utilitza per a produir aigua freda, que s'empra finalment en refredar l'aire de la cabina. El model desenvolupat és completament dinàmic i es basa en models zero dimensionals de paràmetres concentrats, per a tots i cada un dels components del sistema global incloent el motor, els reactors, el circuit d'escalfament, el circuit de refredament, el circuit d'aigua freda i la cabina del vehicle. El model del reactor contempla el no equilibri dels processos d'adsorció o desorció i és capaç de treballar amb qualsevol parell de materials adsorbents. No obstant això, l'estudi s'ha restringit a gel de sílice i zeolita que es troben entre els materials més adequats per a aquesta aplicació. El model s'utilitza per a simular un cicle de conducció estàndard del vehicle, avaluant la calor disponible instantàniament en el sistema de refrigeració del motor, i el comportament dinàmic del sistema descrit Adsorció-Aire Acondicionat, permetent com a resultat principal l'estimació de l'evolució de la temperatura de la cabina al llarg del cicle. El model del sistema global s'ha desenvolupat en l'entorn de programació MATLAB Simulink. El model del sistema d'adsorció s'ha validat primer amb resultats experimentals demostrant les excel¿lents capacitats del model per a predir el comportament dinàmic del sistema. A continuació, el model s'ha aplicat per analitzar la influència dels principals paràmetres de disseny del reactor, i dels principals paràmetres d'operació, sobre el rendiment del sistema: la capacitat i coeficient d'operació (COP), amb la finalitat de proporcionar directrius per al disseny i operació òptima d'aquest tipus de sistemes. Finalment, el model ha estat utilitzat per analitzar el funcionament i prestacions del sistema en el seu conjunt (motor, sistema d'absorció, els circuits de calefacció i refrigeració, circuit d'aigua freda, i la cabina) al llarg d'un cicle de conducció estàndard, sota diferents estratègies d'operació pel que fa a l'estat inicial del material adsorbent en els reactors, i les condicions d'operació, per al cas d'un cotxe, i per al d'un camió. Els resultats mostren les dificultats de l'activació del sistema en els períodes inicials del cicle, quan el motor s'està escalfant, i les dificultats per sincronitzar el funcionament del sistema amb la disponibilitat d'energia tèrmica excedent del motor, així com la limitació en la capacitat de refredament del sistema dissenyat, que no resulta capaç de satisfer els requeriments mínims de confort dins de la cabina en els dies calorosos o de refredar amb suficient rapidesa quan el vehicle ha estat estacionat sota el sol durant diverses hores. Part d'aquest estudi de doctorat s'ha dut a terme en el marc d'un projecte d'I + D denominat "Thermally Operated Mobile Air Conditioning Systems - TOPMACS", finançat parcialment per la UE en el marc del programa FP6, i que perseguia l'avaluació de la viabilitat i el potencial d'aplicació de solucions de sistemes d'adsorció activats per la calor residual del motor per a l'aire condicionat de vehicles.
Verde Trindade, M. (2015). MODELLING AND OPTIMIZATION OF AN ADSORPTION COOLING SYSTEM FOR AUTOMOTIVE APPLICATIONS [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/54120
TESIS
Perez, Garnes Manuel. "Structures based on semi-degradable biomaterials for neural regeneration in the central nervous system." Doctoral thesis, Universitat Politècnica de València, 2015. http://hdl.handle.net/10251/48799.
Full textPerez Garnes, M. (2015). Structures based on semi-degradable biomaterials for neural regeneration in the central nervous system [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/48799
TESIS
Koláček, Richard. "Výkonové parametry systému pro energetické využití biomasy." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2008. http://www.nusl.cz/ntk/nusl-228093.
Full textBaiget, Orts María Amparo. "HYALURONAN BASED BIOMATERIALS FOR CENTRAL NERVOUS TISSUE REGENERATION." Doctoral thesis, Universitat Politècnica de València, 2012. http://hdl.handle.net/10251/14576.
Full textBaiget Orts, MA. (2012). HYALURONAN BASED BIOMATERIALS FOR CENTRAL NERVOUS TISSUE REGENERATION [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/14576
Palancia
Djuric, Natasa. "Real-time supervision of building HVAC system performance." Doctoral thesis, Norwegian University of Science and Technology, Faculty of Engineering Science and Technology, 2008. http://urn.kb.se/resolve?urn=urn:nbn:no:ntnu:diva-2215.
Full textThis thesis presents techniques for improving building HVAC system performance in existing buildings generated using simulation-based tools and real data. Therefore, one of the aims has been to research the needs and possibilities to assess and improve building HVAC system performance. In addition, this thesis aims at an advanced utilization of building energy management system (BEMS) and the provision of useful information to building operators using simulation tools.
Buildings are becoming more complex systems with many elements, while BEMS provide many data about the building systems. There are, however, many faults and issues in building performance, but there are legislative and cost-benefit forces induced by energy savings. Therefore, both BEMS and the computer-based tools have to be utilized more efficiently to improve building performance.
The thesis consists of four main parts that can be read separately. The first part explains the term commissioning and the commissioning tool work principal based on literature reviews. The second part presents practical experiences and issues introduced through the work on this study. The third part deals with the computer-based tools application in design and operation. This part is divided into two chapters. The first deals with improvement in the design, and the second deals with the improvement in the control strategies. The last part of the thesis gives several rules for fault diagnosis developed using simulation tools. In addition, this part aims at the practical explanation of the faults in the building HVAC systems.
The practical background for the thesis was obtained though two surveys. The first survey was carried out with the aim to find the commissioning targets in Norwegian building facilities. In that way, an overview of the most typical buildings, HVAC equipment, and their related problems was obtained. An on-site survey was carried out on an example building, which was beneficial for introducing the building maintenance structure and the real hydronic heating system faults.
Coupled simulation and optimization programs (EnergyPlus and GenOpt) were utilized for improving the building performances. These tools were used for improving the design and the control strategies in the HVAC systems. Buildings with a hydronic heating system were analyzed for the purpose of improving the design. Since there are issues in using the optimization tool, GenOpt, a few procedures for different practical problems have been suggested. The optimization results show that the choice of the optimization functions influences significantly the design parameters for the hydronic heating system.
Since building construction and equipment characteristics are changing over time, there is a need to find new control strategies which can meet the actual building demand. This problem has been also elaborated on by using EnergyPlus and GenOpt. The control strategies in two different HVAC systems were analyzed, including the hydronic heating system and the ventilation system with the recovery wheel. The developed approach for the strategy optimization includes: involving the optimization variables and the objective function and developing information flow for handling the optimization process.
The real data obtained from BEMS and the additional measurements have been utilized to explain faults in the hydronic heating system. To couple real data and the simple heat balance model, the procedure for the model calibration by use of an optimization algorithm has been developed. Using this model, three operating faults in the hydronic heating system have been elaborated.
Using the simulation tools EnergyPlus and TRNSYS, several fault detection and diagnosis (FDD) rules have been generated. The FDD rules were established in three steps: testing different faults, calculating the performance indices (PI), and classifying the observed PIs. These rules have been established for the air cooling system and the hydronic heating system. The rules can diagnose the control and the component faults. Finally, analyzing the causes and the effects of the tested faults, useful information for the building maintenance has been descriptively explained.
The most important conclusions are related to a practical connection of the real data and simulation-based tools. For a complete understanding of system faults, it is necessary to provide real-life information. Even though BEMS provides many building data, it was proven that BEMS is not completely utilized. Therefore, the control strategies can always be improved and tuned to the actual building demands using the simulation and optimization tools. It was proven that many different FDD rules for HVAC systems can be generated using the simulation tools. Therefore, these FDD rules can be used as manual instructions for the building operators or as a framework for the automated FDD algorithms.
Denne avhandlingen presenterer noen fremgangsmåter for forbedring av ytelser for VVS-tekniske anlegg i eksisterende bygninger basert på bruk av simuleringsverktøy og virkelige måledata. Ett av målene har vært å undersøke behov og muligheter for vurdering og forbedring av ytelser for VVS-anlegg i bygninger. I tillegg har denne avhandlingen hatt som mål å fremme bruk av SD-anlegg samt å fremskaffe nyttig informasjon til driftspersonalet.
Bygninger blir stadig mer kompliserte systemer som inneholder flere og flere komponenter mens SD-anlegg håndterer en stadig større mengde data fra bygningsinstallasjoner. På den ene siden registreres det ofte feil og problemer med hensyn til ytelsene til de VVS-tekniske installasjonene. På den andre siden innføres det stadig strengere lovmessige pålegg og kost-nyttekrav motivert i energieffektiviseringen. SD-anlegg og databaserte verktøy bør derfor brukes mer effektivt for forbedring av ytelsene.
Avhandlingen består av fire hoveddeler hvor hver del kan leses separat. Den første delen, som er basert på literatturstudie, forklarer funksjonskontroll som begrep og prinsipper for oppbygging av verktøy for funksjonskontroll. Den andre delen presenterer praktisk erfaring og problemstillinger utviklet og behandlet i løpet av arbeidet med avhandlingen. Den tredje delen handler om anvendelse av databaserte verktøy for forbedring av ytelsen for VVS-tekniske installasjoner. Den tredje delen er delt opp i to kapitler, hvorav et handler om forbedring av systemløsninger og et om forbedring av styringsstrategier. Den siste delen presenterer flere regler for feilsøking og diagnostisering utviklet gjennom bruk av simuleringsverktøy. I tillegg gir denne delen en praktisk forklaring av feilene i de VVS-anleggene som er behandlet i undersøkelsen.
Det praktiske grunnlaget for avhandlingen er etablert gjennom to undersøkelser. Den første var en spørreundersøkelse som hadde til hensikt å kartlegge målsetninger for funksjonskontroll i norske bygninger. Gjennom dette ble det etablert en oversikt over de mest typiske bygninger med tilhørende VVS-anlegg og de mest forekommende problemene. En dypere undersøkelse ble utført på ett casebygg. Denne undersøkelsen viste seg å være nyttig både for kartlegging av betydningen av organisering av driften av bygningen og for avdekking av de virkelige feilene i det vannbårne oppvarmingssystemet.
En kobling mellom et simulerings- og et optimaliseringsprogram (EnergyPlus og GenOpt) har vært benyttet for forbedring av ytelsene for de VVS-tekniske installasjonene. Disse verktøyene har vært brukt for forbedring av både systemløsningene og styringsstrategiene for VVS-anlegg. Bygninger med vannbåren oppvarmingssystem har vært analysert for å forbedre systemløsningen. På grunn av begrensninger i bruken av optimaliseringsverktøyet GenOpt, har det blitt utviklet egne prosedyrer for håndtering av visse typer problemstillinger hvor denne begrensningen opptrer. Resultatene for optimaliseringen viser at valg av objektfunksjoner påvirker betydelig parametrene i det vannbårne oppvarmingssystemet.
Endringer i egenskapene til både bygningskonstruksjoner og utstyr som skjer på grunn av aldring over tiden, gjør det nødvendig med tilpassning av styringsstrategier slik at det virkelige behovet kan bli dekket. Denne problemstillingen har vært analysert ved bruk av EnergyPlus og GenOpt. Styringsstrategiene for to forskjellige VVS-anlegg, et vannbåret oppvarmingssystem og et ventilasjonsanlegg med varmegjenvinner har blitt behandlet. Den utviklete prosedyren for optimalisering av styringsstrategien består av følgende steg: innføring av optimaliseringsvariabler og objektfunksjon, samt utvikling av informasjonsflyt for behandling av optimaliseringsprosessen.
De virkelige data, både fra SD-anlegg og tilleggsmålinger, har vært benyttet for praktisk forklaring av feilene i oppvarmingssystemet. En prosedyre for modellkalibrering basert på bruk av en optimaliseringsalgoritme som kobler sammen de virkelige data og en enkel varmebalansemodell har blitt foreslått. Tre konkrete driftsfeil i oppvarmingssystemet har blitt belyst gjennom bruk av denne varmebalansemodellen.
Flere regler for feilsøking og diagnostisering har blitt utviklet ved hjelp av simuleringsverktøyene EnergyPlus and TRNSYS. Denne utviklingen har bestått av tre ulike steg: testing av bestemte feil, beregning av ytelsesindikatorer og til slutt klassifisering av de observerte ytelsesindikatorer. Reglene har blitt utviklet for et system av aggregater for luftkjøling og for et vannbåret oppvarmingssystem. Reglene kan diagnostisere både styringsfeil og komponentfeil. Til slutt presenteres informasjon som er nyttig for drift av VVS-tekniske installasjoner i bygninger basert på en analyse av årsakene for og virkningene av de feil som er behandlet.
De viktigste konklusjonene er knyttet til praktisk kombinasjon av virkelige måleverdier og simuleringsverktøy. Informasjon fra det virkelig liv er helt nødvendig for å få en god forståelse av feil som oppstår i anlegg. Det er også vist at potensialet som ligger i alle de data som er tilgjengelige gjennom SD-anlegg, ikke er fullt utnyttet. Gjennom bruk av simuleringsverktøy kan styringsstrategiene alltid bli bedre tilpasset og innjustert til de virkelige behov i bygningen. Simuleringsverktøy kan også brukes for utvikling av prosedyrer for feilsøking og diagnostisering i VVS-tekniske anlegg. Disse prosedyrene kan brukes enten som en veileder for manuell feilsøking og detektering eller som grunnlag for utvikling av automatiserte algoritmer.
Paper II, VI and VII are reprinted with kind permission from Elsevier, sciencedirect.com
Hägg, Cecilia. "Ice Slurry as Secondary Fluid in Refrigeration Systems : Fundamentals and Applications in Supermarkets." Licentiate thesis, KTH, Energy Technology, 2005. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-478.
Full textThis thesis summarises the work performed within the project known as ICE-COOL at the Royal Institute of Technology (KTH) on low tem-perature applications of ice slurry. The ICE-COOL project is a Euro-pean Community funded project within the 5th Framework Program. The task given to KTH was to find and characterize the best possible aqueous solution with a freezing point of -25 °C applicable for ice slurry with an operating temperature of -35 °C. The circumstances differ for low temperature ice slurry from medium temperature as a result of for example the change in thermo-physical properties due to increased addi-tive concentration and the lower temperature.
Ice slurry is a mixture of fine ice crystals, water and freezing point de-pressant additives. The typical ice crystal size ranges between 0.1 to 1 mm in diameter. The main purpose of using ice slurries is to take advan-tage of the latent heat. More than a few requirements are to be fulfilled by an ideal ice slurry fluid. It should have good thermo-physical proper-ties, high heat transport and transfer abilities, as well as low pressure drop to facilitate small pumping power. The ice content of ice slurry af-fects all the mentioned abilities. Apart from the mentioned factors of the fluid, there are other aspects that have to be taken into consideration such as environmental pollution and toxicity, flammability, material compatibility, corrosion, handling security and cost.
This thesis reports on the experiences accomplished and the initial ex-periments performed on low temperature ice slurry. The thesis also gives the background and fundamentals necessary for a discussion and com-parison of different aqueous fluids suitable for ice slurry in general and for low temperature in particular. In addition to the low temperature ap-plication, the thesis also reports on an initial energy consumption com-parison between using ice slurry and single-phase fluid in supermarkets by means of the simulation program CyberMart developed by Jaime Arias at the Department of Energy Technology at KTH.
Coimbra, Ricardo Pureza. "Geração de tensão de referencia e sinal de sensoriamento termico usando transistores MOS em forte inversão." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/262029.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação
Made available in DSpace on 2018-08-14T00:43:32Z (GMT). No. of bitstreams: 1 Coimbra_RicardoPureza_M.pdf: 4991793 bytes, checksum: 2b5fb9293ae9abe4c248964485ff74e3 (MD5) Previous issue date: 2009
Resumo: Fontes de referência de tensão e sensores de temperatura são blocos extensivamente utilizados em sistemas microeletrônicos. Como alternativa à aplicação de estruturas consolidadas, mas protegidas por acordos de propriedade intelectual, é permanente a demanda pelo desenvolvimento de novas técnicas e estruturas originais destes circuitos. Também se destaca o crescente interesse por soluções de baixa tensão, baixo consumo e compatíveis com processos convencionais de fabricação. Este trabalho descreve o desenvolvimento de um circuito que atende a estas exigências, fornecendo uma tensão de referência e um sinal de sensoriamento térmico, obtidos a partir de um arranjo adequado de transistores MOS, que operam em regime de forte inversão. O princípio de operação do circuito desenvolvido foi inspirado no conceito de que é possível empilhar n transistores MOS, polarizados com corrente adequada, de tal forma que a queda de tensão sobre a pilha de transistores, com amplitude nVGS, apresente a mesma taxa de variação térmica que a tensão VGS produzida por um único transistor. Nesta condição, a diferença entre as duas tensões é constante em temperatura, constituindo-se em uma referência de tensão. No entanto, o empilhamento de dois ou mais transistores impossibilita a operação do circuito sob baixa tensão. Isto motivou a adaptação da técnica, obtendo a tensão nVGS com o auxílio de um arranjo de resistores, sem o empilhamento de transistores. Desta forma, o potencial limitante da tensão mínima de alimentação tornou-se a própria tensão de referência, cuja amplitude é próxima de um único VGS. A estrutura desenvolvida fornece também um sinal de tensão com dependência aproximadamente linear com a temperatura absoluta, que pode ser aplicado para sensoriamento térmico. Foram fabricados protótipos correspondentes a diversas versões de dimensionamento do circuito para comprovação experimental de seu princípio de operação. O melhor desempenho verificado corresponde à geração de uma tensão de referência com coeficiente térmico de 8,7ppm/ºC, no intervalo de -40ºC a 120ºC, operando com tensão de 1V. Embora o estado da arte seja representado por índices tão baixos quanto 1ppm/ºC, para a mesma faixa de temperatura, a característica compacta do circuito e seu potencial de aplicação sob as condições de baixa tensão e baixo consumo lhe conferem valor como contribuição para este campo de pesquisa e desenvolvimento.
Abstract: Voltage references and temperature sensors are blocks extensively used in microelectronic systems. As an alternative to the use of consolidated structures that are protected by intellectual property agreements, there is a permanent demand for the development of new techniques and structures for these circuits. It can be also highlighted the growing interest for low-voltage and low-power solutions, implemented in conventional IC technologies. This work describes the development of a circuit that meets these requirements by providing a voltage reference and temperature sensing signal obtained from a suitable arrangement of MOS transistors biased in strong inversion. The operation principle of the circuit developed is based on the concept that it is possible for a stack of n MOS transistors, biased by an appropriate current, to show a voltage drop, equal to nVGS, with the same thermal variation rate as a VGS voltage produced by a single transistor. Hence, the difference between the two voltage signals is temperature independent, characterizing a voltage reference. However, the stacking of two or more transistors prevents the operation of the circuit under low voltage. This fact motivated to adapt the technique by obtaining the voltage nVGS with the aid of an array of resistors and no stacked transistors. The minimum supply voltage becomes limited only by the reference voltage itself, whose amplitude is close to a single VGS. The circuit developed also provides a voltage signal almost linearly dependent with the absolute temperature, which can be applied for thermal sensing. Prototypes corresponding to various dimensional versions of the circuit were produced to experimentally verify the principle of operation. The best performance corresponds to the generation of a voltage reference signal with 8.7ppm/ºC thermal coefficient, from -40ºC to 120ºC, under a 1V supply voltage. Although the state of the art is represented by values as low as 1ppm/ºC, at the same temperature range, the circuit's compact aspect together with the possibility to attend low-voltage and low-power requirements grants it value as contribution to this field of research and development
Mestrado
Eletrônica, Microeletrônica e Optoeletrônica
Mestre em Engenharia Elétrica
Real, Minuesa Marcelo. "Modelling, control and diagnosis of aftertreatment systems based on three-way catalyst in spark-ignited engines." Doctoral thesis, Universitat Politècnica de València, 2020. http://hdl.handle.net/10251/137040.
Full text[CAT] Malgrat la tendència actual cap a l'electrificació del transport per carretera, els motors de combustió interna alternatius han sigut essencials en aquest sector i s'espera que continuen sent una tecnologia amb notable presència durant les pròximes dècades. Els vehicles de passatgers actuals basats en motors de combustió interna són més ecològics que els utilitzats fa anys, encara que hi ha treball per fer. Els sistemes de post-tractament estan enfocats a minimitzar tant com siga possible l'impacte dels motors de combustió interna en termes d'emissions contaminants. En el cas dels motors d'encés provocat, els catalitzadors de tres vies representen la tecnologia més estesa en les últimes dècades, pel fet que són compactes i posseeixen bona relació preu-prestacions. Aquests convertidors són capaços d'oxidar hidrocarburs i monòxid de carboni al mateix temps que redueixen els òxids de nitrogen. No obstant això, per a aconseguir la seua millor eficiència, el dosatge ha de controlar-se amb precisió entorn de condicions estequiomètriques. En aquest sentit, els sistemes electrònics de gestió del motor són essencials per a aprofitar les característiques d'aquests convertidors. En particular, les estratègies de control i diagnòstic exerceixen un paper clau per aconseguir una reducció efectiva de les emissions en l'ampli rang de condicions d'operació que es donen en condicions de funcionament reals. El desenvolupament d'aquestes estratègies és fonamental, especialment tenint en compte el baix nivell d'emissions permès per les normatives actuals i la tendència cap a zero emissions. El propòsit d'aquesta tesi doctoral és analitzar el comportament del sistema de post-tractament en condicions específiques però alhora molt comunes en conducció real, i desenvolupar estratègies que proporcionen una reducció addicional de les emissions en sistemes basats en catalitzador de tres vies. Amb la popularització de xicotets motors amb sobrealimentació d'encés provocat, ha augmentat l'ús d'estratègies de curtcircuit per a mitigar els típics problemes de falta de parell a baix règim. Aquesta tesi analitza l'impacte dels polsos de curtcircuit en el catalitzador i en les sondes ¿. El procés de curtcircuit d'aire fresc té un impacte important en la dinàmica intra-cicle de la composició dels gasos. En particular, els polsos de monòxid de carboni i hidrogen seguits pels polsos d'aire fresc pertorben el normal funcionament del sensor d'oxigen. Per tant, s'ha proposat un nou mètode per a estimar la taxa de curtcircuit del motor. Aquest mètode permet corregir la desviació patida pel sensor i, per tant, ajuda a reduir la penalització en emissions d'aquest tipus d'estratègies. Per a millorar l'eficiència del catalitzador en condicions transitòries, no solament es requereix un control precís del dosatge aigües amunt del catalitzador, sinó que també resulta imprescindible considerar el comportament dinàmic del convertidor en si mateix. Per exemple, l'emmagatzematge d'oxigen és un bon indicador de l'estat del catalitzador, però no es pot mesurar directament mitjançant sensors. Per tant, el desenvolupament de models és clau en les estratègies de control actuals, per poder estimar els diferents paràmetres relacionats amb l'estat del catalitzador. Diversos models de catalitzador s'han desenvolupat en aquesta tesi doctoral per a tractar diferents qüestions, des de la predicció dels efectes de la condensació d'aigua en l'evolució de la temperatura del catalitzador just després de l'arrencada en fred, a la quantificació del nivell d'envelliment, passant pel control òptim de porga del catalitzador.
[EN] In spite of the current tendency towards the electrification of the road transport, internal combustion engines have been essential in this sector and it is expected to continue being a technology with a noticeable presence during next decades. Current passenger cars based on internal combustion engines are greener than those used years ago, although it is still a developing process. Aftertreatment systems are aimed to minimize as much a possible the impact of internal combustion engines in terms of pollutant emissions. In case of spark-ignited engines, three-way catalytic converters represent the most widespread technology during last decades, due to their compactness and cost-performance. These converters are capable to oxidise hydrocarbons and carbon monoxide while simultaneously reducing nitrogen oxide. Nonetheless, to achieve their best efficiency, the air-to-fuel ratio must be accurately controlled close to stoichiometric conditions. In this sense, electronic engine management systems are essential to take advantage of the features of these converters. In particular, control and diagnosis strategies play a key role to achieve an effective emissions reduction under the wide range of operating conditions that arise in real driving conditions. The further development of this strategies is fundamental, especially taking into account the low emissions level allowed by current regulatory procedures and the trend towards zero emissions. The purpose of this dissertation is to analyse the behaviour of the aftertreatment system under very specific but at the same time very common conditions, and developing strategies that provide a further emissions reduction for systems based on three-way catalyst. With the popularization of small turbocharged spark-ignited engines, the use of scavenging strategies to solve the typical low-end torque issues has increased. This dissertation analyses the impact of the short-circuit pulses on both three-way catalyst and ¿ sensors. The short-circuit process has an important effect on the in-cycle dynamics of the exhaust gas composition. In particular, the carbon monoxide and hydrogen pulses followed by fresh air pulses cause a sensor bias. Thus a new method to on-line estimate the short-circuit rate has been proposed. This method allows to correct the sensor bias and, therefore, help to reduce the emissions penalty. To improve the TWC efficiency under transient conditions, not only an accurate air-to-fuel ratio control upstream of the converter is required, but also to consider the dynamic behaviour of the converter itself. For example, the oxygen storage is the main responsible for the converter dynamics, and thus, a good indicator of the catalyst state, but it cannot be directly measured. Hence the development of models is key in current control strategies, to on-line track different parameters related with the state of the converter. Several models have been derived in this dissertation in order to fulfil different requirements, from the prediction of water condensation effects on the temperature evolution inside the converter just after cold-start, to the quantification of the ageing level, through the optimal catalyst purge control, or the air-to-fuel ratio disturbances rejection.
Real Minuesa, M. (2020). Modelling, control and diagnosis of aftertreatment systems based on three-way catalyst in spark-ignited engines [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/137040
TESIS
Green, Gustav. "Systemanalys av termisk samverkan mellan solceller och värmepump i flerbostadshus : Modellering och scenarioanalyser av innovativa systemutformningar samt väderförhållanden med fokus på energi, klimat och ekonomi." Thesis, Karlstads universitet, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-67780.
Full textIt is discussed in today’s society to reduce the carbon dioxide emissions by replacing old, fossil fueled, electricity production with new, renewable and “green” ways of producing electricity. Photovoltaics have lately become cheaper which can be seen by looking at the increase in installed electric power from apartment buildings for each year in Sweden. This is mainly caused by the introduction of subsidies towards photovoltaics in 2006 from the Swedish state. The efficiency of photovoltaics increases when the solar radiation is higher but decreases with increasing cell temperature of the photovoltaic cells. The COP of heat pumps, which is commonly used for heating apartment buildings, is increased with increased brine temperature which increases the potential of heating. This means that photovoltaics can benefit from a cold brine while heat pumps can benefit from a higher brine temperature by heat exchanging with photovoltaics. Thermal cooperation is possible. The purpose of the study is to do a system analysis of how photovoltaics and heat pump can cooperate in an energy and cost-efficient energy system through thermal cooperation. Two models, of an energy system in an apartment building located in Karlstad, have been built in this study; with and without thermal cooperation between heat pump and photovoltaics. The energy system is divided in two subsystems; heating and electricity system. The heating system consists of an exhaust air heat pump with district heating during peaks and the electricity system consists of the electricity demand from the apartment building and photovoltaics. The results of the models are compared with focus on purchase of electricity and district heating, selling of electricity, carbon dioxide emissions and economical costs. The results from the models have also been analyzed and compared in 8 different scenarios. The scenarios change the configuration of the energy system and weather factor. Examples of scenarios that have been analyzed are optimization of electricity production and change of geographical location. The models are built in Matlabs modeling program Simulink and are based on energy balances. Data is gathered with help from HSB Värmland, product sheet of the solar panels (one solar panel is a matrix of several photovoltaics), own measurements, assumptions and similar studies from scientific articles. Carbon dioxide emissions are based on the merit order curve for electricity production (“marginal-energy-principle”). An energy system in Karlstad with thermal cooperation, between photovoltaics and exhaust air heat pump, contributes to reduced carbon dioxide emissions by 1239 kg/year (short term) and 448 kg/year (long term). However, it is hard to warrant thermal cooperation from an economical perspective with th. This is because the investment costs of an energy system with thermal cooperation is only allowed to reach a maximum of 7250 kr over 25 years for it to be economically profitable. The amount of electricity that needs to be purchased decreases and the amount of electricity that is sold as well as district heating purchased increases. The yearly average COP of the heat pump increases from 4,56 to 5,30 and the yearly average solar panel efficiency increases from 21,15 to 21,16 %. If the price of electricity increases, then thermal cooperation will become more profitable. One scenario from the scenario analysis stands out in comparison with other scenarios due to reduced yearly costs from a cooperating system of 1920 kr/year. This is when the electricity production from the photovoltaics are optimized. However, this scenario requires adjustments in brine flow, heat exchanger area and external cooling which can cause practical complications. One scenario has the potential to become economically profitable with the construction of new heating systems. This is when the exhaust air recycling is removed from the heating system. The removal of exhaust air recycling in a cooperating system contributes to lower yearly costs but not as low as a cooperating system with exhaust air recycling. However, this might mean that the construction of new heating systems can be profitable without exhaust air recycling because the investment cost of the exhaust air recycling is removed. Since this study has not taken investment and operating costs of exhaust air recycling into account, further studies are needed to determine this. Thermal cooperation is more profitable in warmer countries than Sweden but does not contribute to as low reduction in carbon dioxide emissions. When the energy system is placed in Kiruna, Sweden, it causes both the yearly cost and carbon dioxide emissions to increase. The energy system is placed in Lund, Sweden, yielded similar results as if the system was placed in Karlstad, Sweden. The yearly cost and carbon dioxide emissions decreased when the energy system was placed in Athens, Greece. However, when comparing the energy systems in Athens and Lund, Athens had the lower yearly cost but higher carbon dioxide emissions. Since the energy system placed in Lund contributes to the lowest carbon dioxide emissions in comparison to both Kiruna and Athens then there might be a break point in relation to local climate where the emissions are the lowest possible.
Grozdek, Marino. "Load Shifting and Storage of Cooling Energy through Ice Bank or Ice Slurry Systems modelling and experimental analysis /." Doctoral thesis, Stockholm : Skolan för industriell teknik och management, Kungliga Tekniska högskolan, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-11119.
Full textCervera, Vázquez Javier. "Control and energy optimization of ground source heat pump systems for heating and cooling in buildings." Doctoral thesis, Universitat Politècnica de València, 2016. http://hdl.handle.net/10251/66748.
Full text[ES] En un contexto de creciente preocupación por el calentamiento global y de políticas energéticas internacionales, en el cual los sistemas de climatización en edificios representan una parte importante del consumo energético global, los sistemas de bomba de calor geotérmica están ampliamente considerados como una de las tecnologias de climatización de espacios más eficientes disponibles en la actualidad. Sin embargo, tanto un buen diseño de los componentes como una óptima operación del sistema son de vital importancia para que estos sistemas puedan contribuir de manera significativa a atenuar el problema energético global. El objetivo general de esta tesis doctoral es el control y la optimización energética de una instalación experimental de bomba de calor geotérmica construida en la Universitat Politècnica de València, haciendo que el sistema de control se adapte a la demanda térmica del edificio y a las condiciones climatológicas. Para ello, se proponen diferentes estrategias de control, las cuáles son descritas, desarrolladas, implementadas y evaluadas a lo largo de este trabajo de investigación. La optimización de cualquier sistema requiere un amplio estudio de su comportamiento, analizando concienzudamente todas las variables y parámetros implicados en su funcionamiento. Por tanto, el primer paso llevado a cabo es el análisis de los días típicos de funcionamiento de la instalación, pero también su comportamiento a más largo plazo, a partir de los datos experimentales recogidos. En segundo lugar, y como paso previo al desarrollo de las estrategias de optimización, es importante analizar la configuración óptima del sistema de acuerdo con los objetivos perseguidos. Este objetivo incluye el estudio de la posición del sensor de temperatura empleado para el control y del depósito de inercia, así como el dimensionamiento adecuado de este depósito. Finalmente, una vez se ha analizado en profundidad el funcionamiento del sistema, los componentes del mismo son lo más eficientes posible, y éstos han sido conectados de manera adecuada, el objetivo final es el desarrollo de estrategias de control y optimización energética que optimicen la operación de la instalación experimental de bomba de calor geotérmica. Estas estrategias se dirigen principalmente a la optimización del sistema completo. El objetivo no es optimizar el funcionamiento de cada componente de manera individual, sino optimizar el comportamiento energético del sistema trabajando como un todo. En este sentido, se desarrolló una primera metodología que combinaba la compensación de la temperatura de consigna de la bomba de calor en función de la temperatura ambiente exterior, y la variación de la frecuencia de las bombas de circulación (y por tanto el caudal de agua) en función de la carga térmica del edificio. La aplicación de esta primera estrategia resultó en una importante mejora del rendimiento energético, pero también en la pérdida de confort en algunas de las oficinas climatizadas cuando las condiciones climatológicas eran extremas durante el verano. En consecuencia, la metodología de control y optimización desarrollada fue mejorada dando como resultado un algoritmo global de optimización energética (que es el resultado final de esta tesis), el cual acopla ambas estrategias anteriores de manera que se cumpla el confort del usuario y se mantenga un ahorro de energía significativo. En resumen, esta tesis doctoral proporciona un estudio experimental exhaustivo de la optimización energética de un sistema de bomba de calor geotérmica para la climatización de un edificio de oficinas. Los resultados experimentales para un año completo de funcionamiento del sistema muestran un ahorro de energía significativo en comparación con el modo de control de referencia, hasta un 35% en modo refrigeración y un 53% en modo calefacción, a la vez que se mantiene el confort de los usuarios.
[CAT] En un context de creixent preocupació per l'escalfament global i de polítiques energètiques internacionals, en el qual els sistemes de climatització en edificis representen una part important del consum energètic global, els sistemes de bomba de calor geotèrmica estan amplament considerats com una de les tecnologies de climatització més eficients disponibles en la actualitat pel que fa a la climatització d'espais. No obstant això, tant un bon disseny dels components com una operació òptima del sistema són de vital importància per tal que aquests sistemes puguen contribuir de manera significativa a atenuar el problema energètic global. L'objectiu general d'aquesta tesi doctoral és el control i l'optimització energètica d'una instal·lació experimental de bomba de calor geotèrmica construïda a la Universitat Politècnica de València, fent que el sistema de control s'adapte a la demanda tèrmica de l'edifici i a les condicions climatològiques. Amb aquest objectiu, es proposen diferents estratègies de control, les quals són descrites, desenvolupades, implementades i avaluades al llarg d'aquest treball d'investigació. L'optimització de qualsevol sistema requereix un ampli estudi del seu comportament, analitzant conscienciosament totes les variables i paràmetres implicats en el seu funcionament. Per tant, el primer pas duit a terme és l'anàlisi dels dies típics de funcionament de la instal·lació, però també el seu comportament a més llarg termini, a partir de les dades experimentals recollides. En segon lloc, i com pas previ al desenvolupament de les estratègies d'optimització, és important analitzar la configuració òptima del sistema d'acord als objectius perseguits. Aquest objectiu inclou l'estudi de la posició del sensor de temperatura emprat pel control i del dipòsit d'inèrcia, així com el correcte dimensionament d'aquest dipòsit. Finalment, una vegada s'ha analitzat en profunditat el funcionament del sistema, els components d'aquest són el més eficients possible, i han sigut connectats de manera adequada, l'objectiu final és el desenvolupament d'estratègies de control i optimització energètica les quals optimitzen l'operació de la instal·lació experimental de bomba de calor geotèrmica. Aquestes estratègies es dirigeixen principalment a l'optimització del sistema complet. L'objectiu no és optimitzar el funcionament de cada component de manera aïllada, sinó més bé optimitzar el comportament energètic del sistema treballant com un tot. En aquest sentit, es va desenvolupar una primera metodologia que combinava la compensació de la temperatura de consigna de la bomba de calor en funció de la temperatura ambient exterior, i la variació de la freqüència de les bombes de circulació (i per tant del cabdal d'aigua) en funció de la càrrega tèrmica de l'edifici. L'aplicació d'aquest primer apropament va resultar en una important millora del rendiment energètic, però també en la pèrdua de confort en algunes de les oficines climatitzades quan les condicions climatològiques eren extremes durant l'estiu. En conseqüència, la metodologia de control i optimització desenvolupada va ser millorada resultant en un algoritme global d'optimització energètica (resultat principal d'aquesta tesi), el qual acobla ambdues estratègies anteriors de manera que es complisca el confort de l'usuari i es mantinga un important estalvi d'energia. En resum, aquesta tesi doctoral proporciona un estudi experimental exhaustiu de l'optimit\-zació energètica d'un sistema de bomba de calor geotèrmica per la climatització d'un edifici d'oficines. Els resultats experimentals per un any complet de funcionament del sistema mostren un estalvi d'energia significatiu en comparació amb el mode de control de referencia, fins un 35% en mode refrigeració i un 53% en mode calefacció, a la vegada que es manté el confort dels usuaris.
Cervera Vázquez, J. (2016). Control and energy optimization of ground source heat pump systems for heating and cooling in buildings [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/66748
TESIS
Eriksson, Rickard, and Pontus Andersson. "Thermal storage solutions for a building in a 4th generation district heating system : Development of a dynamic building model in Modelica." Thesis, Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-40114.
Full textBekele, Getachew. "Study into the Potential and Feasibility of a Standalone Solar-Wind Hybrid Electric Energy Supply System." Doctoral thesis, KTH, Tillämpad termodynamik och kylteknik, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-11799.
Full textQC 20100623
Schober, Benjamin. "Membrane Stratified Solar Ponds." Thesis, University of Gävle, Faculty of Engineering and Sustainable Development, 2010. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-7083.
Full textThis project deals with the potential of membrane stratified solar ponds which consist of two water layers, where one is a salt solution here, and a separating translucent membrane. An experimental pond was set up to study the thermal behaviour of such collector systems. The input is mainly solar radiation, sometimes when the ambient temperatures are higher than the pond temperatures also heat from the environment is transferred into the pond.
The measured temperatures of the pond, the ambient temperature, the global radiation and wind speed were the basis data for thermal calculations which showed that the pond was working well as a solar collector and thermal storage system all in one. Heat was not extracted from the pond however, only the losses to the environment were studied.
It was found out that the pond temperatures were higher than the ambient temperature over the whole measurement period of 12 days, and insulation and pollution problems as well as future prospects and suggestions for further studies are discussed at the end of this paper.
Varnier, Olivier Nicolás. "Trends and Limits of Two-Stage Boosting Systems for Automotive Diesel Engines." Doctoral thesis, Universitat Politècnica de València, 2012. http://hdl.handle.net/10251/16880.
Full textVarnier ., ON. (2012). Trends and Limits of Two-Stage Boosting Systems for Automotive Diesel Engines [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/16880
Palancia
Gustafsson, Filip. "Waste heat recovery systems : Fuel energy utilisation for a marine defence platform." Thesis, Blekinge Tekniska Högskola, Institutionen för maskinteknik, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:bth-19681.
Full textDenna rapport är ett examensarbete för BTH i samarbete med företaget Saab Kockums AB. Arbetet utforskar möjligheterna att möta framtida miljömässiga och ekonomiska krav genom att låta fartyg minska sin bränsleförbrukning. System för återvinning av spillvärme (WHRS) fångar upp värmeenergi som vanligtvis kyls ner eller släpps ut i naturen och för den tillbaka till systemet. Termisk energilagring (TES) är metoder för lagring av värme som gör det möjligt att använda termisk energi när det behövs. Vissa applikationer av TES är säsongslagring, där sommarvärme lagras för användning på vintern eller när is produceras under vintern och används för kylning senare. Syftet med denna studie är att undersöka möjligheterna att utnyttja ett fartygs spillvärme genom att omvandla termisk energi till elektrisk energi. Detta examensarbete syftar också till att undersöka förhållandena för hur SaltX Technology’s nanobelagda salt kan användas som en potentiell lösning för lagring av termisk energi. Inledningsvis undersöktes WHRS:s förväntningar och krav i en funktionsanalys. Fortsättningsvis bestod metoden av en kombination av en litteraturstudie och dialoger med intressenter. Litteraturstudien användes som ett verktyg för att identifiera, välja och studera intressanta koncept baserade på vetenskapligt beprövade fakta. Dialoger hölls som ett komplement till litteraturstudien för att hitta information. Studien visade att en organisk Rankine-cykel har den högsta verkningsgraden för låg-medelhög temperatur och därför är bäst lämpad för att återvinna energi buren i kylvattnet samt att en ång-Rankine-cykel är bäst lämpad för att utnyttja energin från avgaserna för direkt användning. Studien erhöll förhållanden för termisk energilagring i salt samt viktiga parametrar för systemet. Slutligen visade resultatet att en Stirlingmotor är det mest effektiva konceptet för omvandling av lagrad energi till elektrisk energi. Slutsatserna är att det finns stora möjligheter för återvinning av restvärme på marina försvarsplattformar. En Stirlingmotor för energiomvandling i kombination med termisk energilagring visar störst potential som ett framtida system för återvinning av spillvärme på denna typen av plattformar.
Persson, Tomas. "Combined solar and pellet heating systems for single-family houses : How to achieve decreased electricity usage, increased system efficiency and increased solar gains." Doctoral thesis, Stockholm : Kungliga Tekniska högskolan, 2006. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-4204.
Full textStrand, Anna. "Optimization of energy dispatch in concentrated solar power systems : Design of dispatch algorithm in concentrated solar power tower system with thermal energy storage for maximized operational revenue." Thesis, KTH, Kraft- och värmeteknologi, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-264410.
Full textKoncentrerad solkraft (CSP) är en snabbt växande teknologi för elektricitets-produktion. Med speglar (heliostater) koncentreras solstrålar på en mottagare som genomflödas av en värmetransporteringsvätska. Denna uppnår därmed höga temperaturer vilket används för att driva en ångturbin för att generera el. Ett CSP kraftverk är oftast kopplat till en energilagringstank, där värmelagringsvätskan lagras innan den används för att generera el. El säljs i de flesta fall på en öppen elmarknad, där spotpriset fluktuerar. Det är därför av stor vikt att generera elen och sälja den vid de timmar med högst elpris, vilket också är av ökande betydelse då supportmekanismerna för att finansiellt stödja förnybar energiproduktion används i allt mindre grad för denna teknologi då den börjar anses mogen att konkurrera utan. Ett solkraftverk har således ett driftsprotokoll som bestämmer när el ska genereras. Dessa protokoll är oftast förutbestämda, vilket innebär att en optimal produktion inte fås då exempelvis elspotpriset och solinstrålningen varierar. I detta examensarbete har en optimeringsalgoritm för elförsäljning designats (i MATLAB). Optimeringsscriptet är designat genom att för en given tidsperiod lösa ett optimeringsproblem där objektivet är maximerad vinst från såld elektricitet från solkraftverket. Funktionen tar hänsyn till timvist varierande elpris, timvist varierande solfältseffektivitet, energiflöden i solkraftverket, kostnader för uppstart (on till off) samt villkor för att logiskt styra de olika driftlägena. För att jämföra prestanda hos ett solkraftverk med det optimerade driftsprotokollet skapades även två traditionella förutbestämda driftprotokoll. Dessa tre driftsstrategier utvärderades i tre olika marknader, en med ett varierande el-spotpris, en i en reglerad elmarknad med tre prisnivåer och en i en marknad med spotpris men noll-pris under de soliga timmarna. Det fanns att det optimerade driftsprotokollet gav både större elproduktion och högre vinst i alla marknader, men störst skillnad fanns i de öppna spotprismarknaderna. För att undersöka i vilket slags kraftverk som protokollet levererar mest förbättring i gjordes en parametrisk analys där storlek på lagringstank och generator varierades, samt optimerarens tidshorisont och kostnad för uppstart. För lagringstank och generator fanns att vinst ökar med ökande storlek upp tills den storlek optimeraren har möjlighet att fördela produktion på dyrast timmar. Ökande storlek efter det ger inte ökad vinst. Ökande tidshorisont ger ökande vinst eftersom optimeraren då har mer information. Att ändra uppstartkostnaden gör att solkraftverket uppträder mindre flexibelt och har färre cykler, dock utan så stor påverkan på inkomst.
Torregrosa, Jaime Bárbara. "Modelling and analysis of an air-conditioning system for vehicles based on magnetocaloric refrigeration." Doctoral thesis, Universitat Politècnica de València, 2016. http://hdl.handle.net/10251/68503.
Full text[ES] En la presente tesis doctoral se ha estudiado la aplicación de un refrigerador magnético en un sistema de aire acondicionado para automóviles. Con el fin de determinar las prestaciones de dicho sistema de manera global y precisa, se ha desarrollado un modelo térmico de cada uno de sus componentes. Por un lado, se ha desarrollado un modelo dinámico unidimensional de regenerador magnético activo (AMR) de placas planas paralelas, basado en un nuevo esquema numérico que reduce el tiempo de cálculo hasta en un 88% respecto al esquema más empleado. El modelo reproduce con gran exactitud los casos de regenerador con solución analítica y ha sido validado exhaustivamente con resultados experimentales funcionando como regenerador pasivo y como AMR. Para obtener buenos ajustes ha sido clave la inclusión en el modelo de las propiedades magnetocalóricas medidas experimentalmente con una muestra del material empleado, el efecto desmagnetizante, la mala distribución del fluido y las pérdidas hacia el ambiente del montaje experimental. La influencia de las incertidumbres y las simplificaciones en el modelado de estos fenómenos se ha analizado detalladamente, lo cual ha permitido validar diferentes aproximaciones. Por otro lado, se ha desarrollado un modelo dinámico del sistema de aire acondicionado de un vehículo eléctrico. Se incluye el modelo térmico de la cabina, los bucles hidráulicos para la distribución de la potencia térmica con los intercambiadores de calor agua-aire y los auxiliares eléctricos. La metodología empleada para el desarrollo de estos modelos, basada en la combinación de ecuaciones de conservación con el ajuste semi-empírico de los coeficientes globales de transmisión de calor, ha producido excelentes resultados de validación con resultados experimentales en un amplio rango de condiciones de funcionamiento. El modelo del vehículo se ha empleado para obtener la demanda de refrigeración y calefacción de un minibús eléctrico comercial, así como las temperaturas de funcionamiento del sistema. Con el modelo de AMR se ha llevado a cabo un amplio estudio de optimización para determinar los parámetros de diseño y de funcionamiento de dicho refrigerador que cubren las necesidades de refrigeración del vehículo una masa del conjunto del sistema y un consumo eléctrico mínimos, incluyendo el consumo de los auxiliares. Adicionalmente se han calculado las prestaciones de calefacción de las combinaciones óptimas. La aplicabilidad de este sistema en automóviles se analiza en comparación con un sistema equivalente de compresión de vapor.
[CAT] En aquesta tesi doctoral s'ha estudiat l'aplicació d'un refrigerador magnètic en un sistema d'aire condicionat per a automòbils. A fi de determinar les prestacions d'aquest sistema de manera global i precisa, s'ha desenvolupat un model tèrmic de cadascun dels components. D'una banda, s'ha desenvolupat un model dinàmic unidimensional de regenerador magnètic actiu (AMR) de plaques planes paral·leles, basat en un nou esquema numèric que redueix el temps de càlcul fins d'un 88% respecte a l'esquema més emprat. El model reprodueix amb gran exactitud els casos de regenerador amb solució analítica, i ha sigut validat exhaustivament amb resultats experimentals funcionant com a regenerador passiu i com a AMR. Per a obtenir bons ajustos ha sigut clau la inclusió en el model de les propietats magnetocalòriques mesurades experimentalment amb una mostra del material emprat, l'efecte desmagnetitzador, la mala distribució del fluid i les pèrdues cap a l'ambient del muntatge experimental. La influència de les incerteses i les simplificacions en la modelització d'aquests fenòmens s'ha analitzat detalladament, la qual cosa ha permès validar diferents aproximacions. D'altra banda, s'ha desenvolupat un model dinàmic del sistema d'aire condicionat d'un vehicle elèctric. S'hi inclouen el model tèrmic de la cabina, els bucles hidràulics per a la distribució de la potència tèrmica amb els bescanviadors de calor aigua-aire i els auxiliars elèctrics. La metodologia emprada per al desenvolupament d'aquests models, basada en la combinació d'equacions de conservació amb l'ajust semiempíric dels coeficients globals de transmissió de calor, ha produït excel·lents resultats de validació amb resultats experimentals en un ampli rang de condicions de funcionament. El model del vehicle s'ha emprat per a obtenir la demanda de refrigeració i calefacció d'un minibús elèctric comercial, així com les temperatures de funcionament del sistema. Amb el model d'AMR s'ha dut a terme un ampli estudi d'optimització per determinar els paràmetres de disseny i de funcionament de la refrigeradora esmentada que cobreixen les necessitats de refrigeració del vehicle, una massa del conjunt del sistema i un consum elèctric mínims, incloent el consum dels auxiliars. Addicionalment s'han calculat les prestacions de calefacció de les combinacions òptimes. L'aplicabilitat d'aquest sistema en automòbils s'analitza comparant-la amb la d'un sistema equivalent de compressió de vapor.
Torregrosa Jaime, B. (2016). Modelling and analysis of an air-conditioning system for vehicles based on magnetocaloric refrigeration [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/68503
TESIS
Premiado
Andersson, Victor. "Väderprognosstyrda värmesystem i byggnader : En jämförelse mot traditionell styrning." Thesis, KTH, Hållbara byggnader, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-254810.
Full textDenna rapport har i avsikt att undersöka hur energianvändningen och värmeeffekterna för uppvärmning påverkas med prognosstyrning i jämförelse med traditionell styrning av värmesystem i lokaler av olika byggnadskonstruktioner. 2013 var energianvändningen 80 TWh för uppvärmning och tappvarmvatten i hushåll och lokalbyggnader. Detta motsvarade då 55 % av den totala energianvändningen inom sektorn där lokaler representerar 28 % av byggnaderna. Med andra ord finns det utrymme för effektivisering av uppvärmningen i lokaler.Krav från direktiv om skärpt energianvändning av byggnader måste införas i svenska regler. Den 19 juni 2018 publicerades nya ändringsdirektiv som måste vara införda i svenska regler senast den 10 mars 2020. Kraven på byggnader blir allt hårdare för att uppnå kraven som ställs från BBR och så även för att uppnå miljöcertifieringar som miljöbyggnad. Det blir alltså allt viktigare att hitta detaljlösningar som kan minska på energianvändningen på byggnader.För att ställa prognosstyrning mot traditionell styrning har en referensbyggnad använts. Den har byggts upp i simuleringsverktyget IDA ICE med tre olika byggnadskonstruktioner. Ett med både högt U-värde och liten termisk massa (originalkonstruktion), en med lägre U-värde men fortfarande liten termisk massa (lätt konstruktion) och en med lägre U-värde och mycket termisk massa (tung konstruktion).Den centralt styrda prognosstyrningen prövades sedan mot den traditionella styrningen för respektive byggnadskonstruktion. Med traditionell styrning används vanligtvis termosstatventiler i lokaler men då hållbarheten på dessa är låg vilket också underhållet av dessa kan vara, prövas även båda strategierna utan termostatventiler också.Resultatet visar att prognosstyrningen förbättrar energianvändningen som mest med 3.4 % i det fallet termostatventiler inte används och 2.7 % i det fallet termostatventiler används. Effekttopparna kan förbättras med 33 % utan termostatventiler och 15 % med termostatventiler. Dessa förbättringar genererades med den tunga konstruktionen. En tung konstruktion kan visa på fördelar med prognosstyrning med avseende på lägre effekttoppar. Utifrån resultaten går det däremot inte att se några fördelar med avseende på energianvändningen.Stora fördelar kunde däremot gå att se med lokal reglering med termostatventiler, vilket var särskilt gynnsamt för byggnader med högt U-värde och låg termisk massa. Resultatet visade då på en förbättring med 30 % för den traditionella styrningen och 28 % för prognosstyrningen när jämförelse med om de inte användes.En god förståelse av byggnadsstommens karaktär har en betydande roll för valet av reglersystem. Prognosstyrning kan vara fördelaktigt med avseende på toppeffekterna, framför allt med den tunga konstruktionen i resultatet. För att minska på energianvändningen är det dock troligtvis viktigast att se över och injustera det befintliga systemet på både central som lokal nivå.
Condò, Marco. "Electrical characterization of innovative insulating materials for HVDC energy transmission cable systems." Master's thesis, Alma Mater Studiorum - Università di Bologna, 2019.
Find full textRelefors, Axel. "Investigation and Application of Safety Parameters for Lithium-ion Battery Systems." Thesis, KTH, Skolan för kemi, bioteknologi och hälsa (CBH), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-281226.
Full textFörsvarsmakten undersöker högriskapplikationer där litiumjonbatterier kan ersätta traditionella blysyrabatterier. Att förstå säkerhetsrisker och utvärdera ett batteris instabilitet är särskilt viktigt för militära tillämpningar. Denna rapport syftar till att identifiera kritiska säkerhetsparametrar (temperatur, spänning och impedans) för kommersiella batterier med NMC- och LFP-elektrodkemier samt undersöka hur omkringliggande celler påverkas när ett batteri termiskt rusar (TR) i en batterimodul utvecklad av FOI. ARC-experiment genomfördes på NMC-baserad Samsung SDI INR21700-40T och INR21700-50E och A123 Systems ANR26650m1-B batterier för att karakterisera förloppet av termisk rusning (TR). ARC-experiment utfördes med kontinuerliga elektrokemisk impedansspektroskopi (EIS) för att korrelera termiskt beteende med elektrokemiska förändringar i cellimpedansen och spänningen. Det NMC-baserade batterierna uppvisade en tydlig endotermisk reaktion mellan 116 °C och 121 °C, exotermiska reaktioner påbörjades vid 120 °C och ledde till explosiv termisk rusning vid cirka 170 °C, vilket gav upphov till en adiabatisk temperaturökning på 250 °C till 290 °C. En signifikant ökning av cellens impedans vid cirka 100 °C indikerade att den inre säkerhetsventilen utlöstes på grund av gasbildning och kritisk tryckuppbyggnad i cellen. Det LFP-baserade batteriet visade förbättrad termisk stabilitet under ARC-mätningar och drabbades inte av TR vid uppvärmning till 300 °C. Termiska rusningsförsök genomfördes på en batterimodul utvecklad av FOI. De identifierade starttemperaturerna och elektrokemiska markörerna användes för att utvärdera modulcellernas stabilitet. Celltemperaturökningar mellan 16 °C och 48 °C observerades i celler direkt intill triggcellen. Celler längre från triggcellen upplevde likformiga temperaturökningar mellan 8 °C och 30 °C. EIS-mätningar av modulcellerna avslöjade inga signifikanta förändringar i deras impedansspektra. Det isolerande polymeromslaget runt varje cell var avgörande för att förhindra propagering av termisk rusning i modulen. Termisk rusning propagerade från cell till cell i modulen när de isolerande omslagen togs bort och cellerna var i direkt kontakt med den värmeledande kylflänsen.
Vaquerizo, Sánchez Daniel. "Study on Advanced Spray-Guided Gasoline Direct Injection Systems." Doctoral thesis, Universitat Politècnica de València, 2018. http://hdl.handle.net/10251/99568.
Full textAbstract Fuel injection systems have been one of the main focal points of engine research, particularly in Diesel engines, where the internal geometry, needle lift and flow behavior are known to affect the external spray an in turn completely determine the combustion process inside engines. Because of environmental regulation and the potential development of the more inefficient Otto engines, a lot of research efforts are currently focused into gasoline direct injection systems. GDi engines have the potential to greatly increase fuel economy and comply with pollutant and greenhouse gases emissions limits, although many challenges still remain. The current thesis studies in detail a modern type of GDi nozzle that was specifically developed for the international research group known as the Engine Combustion Network (ECN). With the objective of employing state-of-the-art techniques, this hardware has been used in a wide range of experimental facilities in order to characterize the internal flow and several geometrical and constructive aspects like needle lift; and assess how it relates to the effects seen external spray. For the internal flow characterization, the goal was to determine the nozzle geometry and needle displacement, to characterize the rate of injection and rate of momentum, and evaluate the near-nozzle flow. Some methodologies applied here have never been applied to a GDi injector before, and many have only been applied rarely. For the internal geometry, needle lift and near-nozzle flow, several advanced x-rays techniques were used at Argonne National Laboratory. For the rate of injection and rate of momentum measurements, the techniques available in CMT-Motores Térmicos have been adapted from Diesel spray research and brought to multi-hole GDi injectors. Given the novelty of the techniques used, the particular methodologies and setups are discussed in detail. Despite the high turbulence of the flow, it was seen that the injector behaves consistently injection to injection, even when studying variation in individual holes. This is attributed to the repetitive behavior of the needle that was observed in the experiments. It was also observed that the stabilized flow has a high frequency variability that could not be explained by random movement of the needle, but rather by the particular design of the nozzle. The geometrical analysis done to eight, nominally equal nozzles, allowed a unique view into the construction of the nozzle and provided insights about the variability of key dimensions. The rate of injection measurements allowed to study the hydraulic response of the injector to the main variables like rail pressure, discharge pressure, fuel temperature and command signal duration. These measurements were combined with the rate of momentum measurements to study the low value of the discharge coefficient, that ultimately was attributed to the low needle lift and low L/D ratio of the orifices. On the other hand, the study of the external spray yielded the identification of very important phenomena specific to this particular hardware, the spray collapse. The extensive experimental campaigns featuring shadowgraph (Schlieren) and Diffused Back Illumination (DBI) visualization techniques allowed identifying and describing the macroscopic characteristics of the spray and the conditions under which the collapse occurs. The spray collapse engenders from a combination of the internal flow that creates plume interaction, and ambient conditions that promote air entrainment and evaporation. At moderate density and temperature levels the collapse develops, completely modifying the expected trends in the behavior of the plumes.
Resum Els sistemes d'injecció directa han sigut un dels principals punts focals de la investigació en motors, particularment en sistemes dièsel, en què la geometria interna, el moviment de l'agulla i el comportament del flux afecten l'esprai extern i per tant determinen completament el procés de combustió dins del motor. Degut a regulacions mediambientals i al potencial dels (més ineficients) motors "Otto", grans esforços s'estan aportant en investigació sobre sistemes d'injecció directa de gasolina. Els motors GDi tenen el potencial d'incrementar substancialment l'economia del combustible i complir les regulacions de gasos contaminants i d'efecte hivernacle, encara que existeixen molts desafiaments per davant. Esta tesi estudia en detall una moderna tovera GDi que va ser especialment dissenyada per al grup d'investigació conegut com a ECN. Amb l'objectiu de desenvolupar metodologies punteres, este injector ha sigut usat en un ampli ventall d'instal·lacions experimentals per tal de caracteritzar el flux intern i diverses característiques clau de la seua geometria i funcionament, per tal d'avaluar com es relacionen amb els efectes observats del comportament de l'esprai extern. Per a la caracterització interna del flux, l'objectiu ha sigut determinar la geometria de la tovera i el desplaçament de l'agulla, caracteritzar la taxa d'injecció i el flux de quantitat de moviment, i avaluar el flux proper. Algunes metodologies no s'havien empleat abans en injectors GDi, i moltes altres ho han sigut únicament de manera eventual. Per a la geometria interna, l'alçament de l'agulla i el flux proper, s'han aplicat diverses tècniques avançades amb raigsx a les instal·lacions d'Argonne National Laboratory. Per a la taxa d'injecció i el flux de quantitat de moviment, les tècniques disponibles al departament han sigut adaptades des de Dièsel i aplicades a injectors GDi multi-orifici. Considerant la novetat de les tècniques aplicades, les particularitats de les metodologies es discuteixen en detall al document. A pesar de l'elevada turbulència del flux intern, l'injector es comporta de manera consistent injecció a injecció, inclús quan l'estudi se centra en la variabilitat orifici a orifici. Aquest fet s'ha atribuït al comportament repetitiu de l'agulla, avaluat als experiments. També es va observar que el flux estabilitzat té una variació d'altra freqüència que no pot ser explicat pel moviment de l'agulla, sinó pel particular disseny de les toveres. L'anàlisi de la geometria interna realitzat a vuit toveres nominalment iguals va permetre obtenir un punt de vista únic en la construcció de toveres i la variabilitat de dimensions clau. Les mesures de taxa d'injecció van permetre estudiar la resposta hidràulica de l'injector a diverses variables com la pressió d'injecció, la pressió de descàrrega, la temperatura del combustible i la duració de la senyal de comandament. Estes mesures van ser combinades amb mesures de flux de quantitat de moviment per tal d'estudiar el baix valor del coeficient de descàrrega, el qual va ser atribuït al baix alçament de l'agulla i al coeficient L/D dels orificis. D'altra banda, l'estudi de l'esprai extern va permetre identificar un important fenomen específic d'aquest hardware particular: el col·lapse de l'esprai. Les extensives campanyes experimentals, utilitzant Schlieren i il·luminació darrera difusa (DBI) van permetre identificar i descriure les característiques macroscòpiques de l'esprai i les condicions sota les quals el col·lapse té lloc. El col·lapse de l'esprai es forma per una combinació d'interacció de les diverses plomes (causat pel flux intern) i determinades condicions ambient que promouen evaporació i entrada d'aire. Es va determinar a quins nivells de densitat i temperatura moderats es desenvolupa el col·lapse, modificant completament el comportament esperat de l'esprai.
Vaquerizo Sánchez, D. (2018). Study on Advanced Spray-Guided Gasoline Direct Injection Systems [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/99568
TESIS
Ismail, Dahman, and Alexis Andrei. "Thermomechanical stress analysis of the main insulation system of traction electrical machines." Thesis, Blekinge Tekniska Högskola, Institutionen för maskinteknik, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:bth-20305.
Full textMer effektiva tunga fordon utvecklas med högre räckvidd, uppdaterade elektroniska och mekaniska delar. Bränsleeffektiviteten och föroreningen av koldioxid måste vara lägre för att uppnå nya EU-förordningar. Antalet tunga fordon ökar i takt med att den globala befolkningen ökar, detta leder i sin tur till ökad utsläpp av bland annat koldioxid. Genom att ta de elektriska och mekaniska delarna till nästa steg kan de globala utsläppsproblemen minskas massivt. Elektriska maskiner för framdrivning är nästa steg mot en renare framtid. Studiens huvudmål för att undersöka den elektriska maskinens isoleringssystem. Termomekaniska påfrestningar på grund av termisk cykling påverkar de elektriska maskinerna och dess delkomponenter. Genom att använda en FEM-applikation med förenklade modeller av den elektriska maskinen erhålls och diskuteras resultat. Specifikt om 2D-modeller är tillräckliga för att representera en 3D-modell. Hur tillräckligt de olika 2D-modeller kan representera 3D-modellen jämförs och diskuteras i denna studie. Ett fysiskt experiment utförs för att validera och kalibrera FEA-modellerna. Vilken av de mindre frekventa cykler med högre amplitud eller mer frekventa cyckler med lägre amplitud påverkar isoleringssystemet mest har undersökts. Simuleringarna kan göras med antingen, temperatur kopplad förskjutnings analys eller sekventiellt kopplad analys. Temperatur kopplad kopplad förskjutning är den snabbaste metoden att använda i simuleringsmodellerna. En 3D-modell är det bästa sättet att beskriva ett objekt och har därför implementerats. Ytterligare två, 2Dmodeller är framtagna i FEM-miljö för snabbare beräkning och för att undersöka om 2D-modellerna kan representera den tredimensionella geometrin. Samtliga tre modeller har specifika randvillkor för att förenkla modellerna. Känslighetsstudier görs för att bestämma vilken parameter som påverkar de inducerade termomekaniska spänningarna mest. Ett fysiskt experiment har utförsts för att validera och kalibrera simuleringsmodellerna. Resultatet visar att 3D-modellen representerar ett tre dimensonellt objekt bäst. Simuleringsresultat har visat att epoxy, som är en av huvudkomponenterna i isoleringssystemet, är mest kritisk när det gäller att först nå brott- och sträckgräns, följt av pappersisolering och koppar beläggningen. Detta är ett typiskt resultat av alla tre simuleringsmodeller. Slutsatsen visar att vissa 2D-modeller kan presentera 3D-modellen, andra kan inte. Den beroende faktorn beror på ur vilket tvärsnitt man tittar på den elektriska maskinen. Det fysiska experimentet visar liknande resultat jämfört med simuleringen när det gäller belastning vid en lägre temperatur, och avvikelsen blir större när temperaturen ökar. 3D-modellen, är den modell som har den bästa representationen av en riktig elektrisk maskin eftersom den inkluderar normal- och skjuvspänningskomponenter i alla riktningar. Anledningen är att den har bättre randvillkor jämfört med 2Dmodellerna. 2D-modellen i XY-planet har visat liknande resultat som 3D-modellen. En av huvudkomponenterna i isoleringssystemet, epoxy, utsätts för de högsta spänningarna jämfört med dess sträck- och den brottgräns, följt av pappersisolering och koppar beläggning. Känslighetsstudien har kommit fram till att statorns axiella längd inte påverkar spänningsamplituderna. Den mest kritiska parametern som påverkar de termomekaniska spänningarna är temperatur amplituden, materialens CTE och tjockleken på det skarvade skiktet. Alla maximala spänningsamplituder för samtliga tre komponenter är belägna i den fria änden.
Mora, Pérez Javier. "Control-oriented modelling and diagnostics of diesel after-treatment catalysts." Doctoral thesis, Universitat Politècnica de València, 2019. http://hdl.handle.net/10251/115937.
Full text[CAT] Esta tesi doctoral abasta el desenvolupament d'algoritmes orientats a millor el sistema de control d'emissions en motors Diesel. Per a este propòsit, la inclusió en el vehicle de sensor embarcats com els de temperatura, els de NOx o el d'NH3 permet realitzar el diagnòstic a bord dels sistemes de post-tractament focus d'este treball, els quals són el DOC i el SCR. Així doncs, l'objectiu és el de satisfer les normatives de diagnòstic a bord per a mantindre les emissions per baix de l'umbral permés per la normativa al llarg del temps. Els tests experimentals, incloent les mesures amb analitzador de gasos, permeten obtindre una visió més àmplia de les espècies en la línia d'escapament. Complementàriament, s'utilitzen unitats noves i envellides per tal de tindre l'efecte experimental de l'envelliment en els catalitzadors. D'aquesta manera, s'analitza l'efecte de la temperatura, la despesa d'escapament, les concentracions de les espècies i l'envelliment en el DOC i en el SCR, així com l'avaluació d'algunes mesures rellevants realitzades pels sensors. Les temperatures tenen una influència destacada en el funcionament dels catalitzadors, pel que es requerix l'avaluació de les mesures dels sensors de temperatura, junt amb el desenvolupament de models de transmissió de calor, per a alimentar les funcions a continuació desenvolupades. En este sentit, la mesura lenta del sensor a l'entrada del DOC es millora en condicions transitòries mitjançant una tècnica de fusió de la informació basada en un filtre de Kalman. Després, es presenta un model de transmissió de calor 1D i un model agrupat 0D, en els quals s'avaluen les entrades a l'entrada segons l'ús del model. Per altra banda, es presenta una tècnica per a estimar l'increment de temperatura degut a l'oxidació dels polsos de post-injecció en el DOC. Es proposen models per a DOC i SCR per a estimar l'efecte de l'envelliment en les emissions, en els quals es modela el factor d'envelliment com un paràmetre sintonitzable, que permet variar des d'estats nous a envellits. Per altra banda, un model agrupat 0D _es desenvolupat per al DOC amb el propòsit d'estimar la relliscada de HC i CO, el qual és validat en un WLTC per a després ser usat en simulació. Per altra banda, un model 1D i un model 0D es desenvolupen per al SCR, els quals s'usen a continuació per a alimentar l'estratègia de diagnòstic i per a simulació. Finalment, les estratègies de diagnòstic es presenten per a la fallada total o retirada del DOC, així com per a l'estimació de l'eficiència en DOC i SCR. Per altra banda, la primera estratègia es divideix en passiva i activa, en la que s'utilitzen post-injeccions en la activa per a excitar el sistema i confirmar la fallada total si es dona el cas. A continuació, l'eficiència del DOC s'estima a través d'una tècnica indirecta en la que la temperatura d'activació es detecta i es relaciona amb l'increment d'emissions a través del model. Per altra banda, es desenvolupa un observador per a estimar l'estat d'envelliment del SCR, el qual està basat en un filtre de Kalman extés. No obstant això, per a evitar associar baixa eficiència degut a pobre qualitat de l'urea injectada a l'envelliment del SCR, un indicador de la qualitat de l'urea s'executa en paral·lel.
[EN] This dissertation covers the development of algorithms oriented to improve the emission control system of Diesel engines. For this purpose, the inclusion of on-board sensors like temperature, NOx and NH3 sensors allows performing on-board diagnostics to the after-treatment systems focus of this work, which are the DOC and the SCR system. Then, the target is to meet on-board diagnostics regulations in order to keep emissions below a regulation threshold over time. Experimental tests, including gas analyzer measurements, allow having a wider view of the species in the exhaust line. Complementary, new and aged units are used in order to have the experimental effect of ageing on the catalysts. Then, the effect of temperature, exhaust mass flow, species concentrations and ageing is analyzed for DOC and SCR, in combination with the assessment of some relevant sensors measurements. As a result, the characteristics, opportunities and limitations extracted from experimental data are used as the basis for the development of models and diagnostics techniques. The assessment of temperature sensors measurements, along with the development of heat transfer models is required to feed temperature dependent functions. In this sense, the slow measurement of the DOC upstream temperature sensor is improved in transient conditions by means of a data fusion technique, based on a fast model and a Kalman filter. Then, a 1D and a 0D lumped heat transfer models are presented, in which the upstream inputs are assessed in relation to its use. On the other hand, a technique to estimate the temperature increase due to post-injection pulses oxidation is also presented. Both DOC and SCR models are proposed in order to estimate the effect of ageing on emissions, in which an ageing factor is modelled as a tunable parameter that allows varying from new to aged states. On the one hand, a 0D lumped model is developed for DOC in order to estimate the HC and CO species slip, which is validated in a WLTC and is then used for simulation. On the other hand, a 1D and a 0D models are developed for SCR, which are then used to feed the diagnostics strategy and for simulation. Finally, diagnostics strategies are presented for total failure or removal of DOC, as well as for efficiency estimation of DOC and SCR. On the one hand, the former strategy is separated into passive and active diagnostics, in which post-injections are used in active diagnostics in order to excite the system and confirm a total failure, in case. Then, the DOC efficiency estimation is done by means of an indirect technique in which the light-off temperature is detected and an emissions increase is related by means of the DOC ageing model. On the other hand, an observer to estimate the SCR ageing state is developed, which is based on an extended Kalman filter. However, in order to avoid associating low SCR efficiency to ageing, an indicator of the injected urea quality is developed to run in parallel.
Mora Pérez, J. (2018). Control-oriented modelling and diagnostics of diesel after-treatment catalysts [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/115937
TESIS
Davidsson, Lukas, and Isak Alsterlund. "Badrumsrenovering i bostäder : Jämförelse mellan radiatorsystem och golvvärmesystem ur energi-, fukt- och komfortaspekt i Västerås." Thesis, Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-45091.
Full textGonilho, Marcos Diogo Mota. "A reabilitação energicamente sustentável e a requalificação do (ex) Convento de Santa Marta." Master's thesis, Universidade de Lisboa. Faculdade de Arquitetura, 2013. http://hdl.handle.net/10400.5/6679.
Full text