Academic literature on the topic 'Third harmonic resistive leakage current'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Third harmonic resistive leakage current.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Third harmonic resistive leakage current"

1

Anil, S. Khopkar, and S. Pandya Katik. "Online Condition Monitoring Technique for Metal Oxide Surge Arresters Based on Leakage Current Components." Engineering and Technology Journal 10, no. 03 (2025): 4095–98. https://doi.org/10.5281/zenodo.15031429.

Full text
Abstract:
Metal Oxide Surge Arresters (MOSA) are connected in the system for protection of power system against over voltages. MOSA behaves as an insulator under normal working condition and offers conductive path under over voltage condition.  Zinc oxide elements (ZnO Blocks) having non-linear voltage-current characteristics is used in construction of MOSA. Ageing effect under various operating conditions such as pollution, moisture ingress caused degradation of MOSA. Degradation of zinc oxide elements increase the leakage current flowing through it which can create thermal runaway conditions for
APA, Harvard, Vancouver, ISO, and other styles
2

Dai, Xian Bin, Xiao Hua Yuan, Wen Yao Sun, and Xin Liu. "Simulation Study of the MOA Resistive Leakage Current Detection Method." Advanced Materials Research 655-657 (January 2013): 177–84. http://dx.doi.org/10.4028/www.scientific.net/amr.655-657.177.

Full text
Abstract:
On-line monitoring of the insulating state of metal oxide surge arresters (MOA) is monitoring its resistive leakage current. This paper analyses the common detection methods of resistive current, pointed out the problems. According to the relationship among the grid voltage and the flow through the leakage current of MOA, the resistive and capacitive current, put forward a new resistive leakage current detection method, and established a mathematical model. Using this mathematical model, new detection method can be verified by simulation. Confirmed that the new method can effectively reduce th
APA, Harvard, Vancouver, ISO, and other styles
3

Novizon, Abdul-Malek Zulkurnain, and Aulia. "Artificial Neural Network Application for Thermal Image Based Condition Monitoring of Zinc Oxide Surge Arresters." Indonesian Journal of Electrical Engineering and Computer Science 5, no. 1 (2017): 593–605. https://doi.org/10.11591/ijeecs.v7.i3.pp593-605.

Full text
Abstract:
Manual analysis of thermal image for detecting defects and classifying of condition of surge arrester take a long time. Artificial neural network is good tool for predict and classify data. This study applied neural network for classify the degree of degradation of surge arrester. Thermal image as input of neural network was segmented using Otsu’s segmentation and histogram method to get features of thermal image. Leakage current as a target of supervise neural network was extracted and applied Fast Fourier Transform to get third harmonic of resistive leakage current. The classification
APA, Harvard, Vancouver, ISO, and other styles
4

Novizon, Novizon, Zulkurnain Abdul-Malek, and Aulia Aulia. "Artificial Neural Network Application for Thermal Image Based Condition Monitoring of Zinc Oxide Surge Arresters." Indonesian Journal of Electrical Engineering and Computer Science 7, no. 3 (2017): 593. http://dx.doi.org/10.11591/ijeecs.v7.i3.pp593-605.

Full text
Abstract:
<p>Manual analysis of thermal image for detecting defects and classifying of condition of surge arrester take a long time. Artificial neural network is good tool for predict and classify data. This study applied neural network for classify the degree of degradation of surge arrester. Thermal image as input of neural network was segmented using Otsu’s segmentation and histogram method to get features of thermal image. Leakage current as a target of supervise neural network was extracted and applied Fast Fourier Transform to get third harmonic of resistive leakage current. The classificati
APA, Harvard, Vancouver, ISO, and other styles
5

Saeed, Vahabi Mashak, Zulkurnain Abdul-Malek, Nabipour Afrouzi Hadi, Chin Leong Wooi, and Amir Hesam Khavari. "Surge Arrester Leakage Current Analysis by Using Particle Swarm Optimization Technique." Applied Mechanics and Materials 554 (June 2014): 608–12. http://dx.doi.org/10.4028/www.scientific.net/amm.554.608.

Full text
Abstract:
Surge arresters, as protective equipment, are used to limit any overvoltage in a power system resulting from various sources. The surge arrester affects from degradation due to the continuous operating voltage system as well as due to repeated lightning current discharge. Therefore, condition monitoring and health diagnostics of surge arresters are a necessary issue. Hence, as a feasible solution, a condition monitoring based on leakage current measurement techniques was selected to tackle the problem of age diagnostics of surge arresters. The Particle Swarm Search Algorithm was introduced as
APA, Harvard, Vancouver, ISO, and other styles
6

Xia, Xing-Yu, Feng Zhang, Shu Pan, et al. "Research on Leakage Current Waveform Spectrum Characteristics of Artificial Pollution Composite Insulator." Journal of Nanoelectronics and Optoelectronics 19, no. 5 (2024): 465–71. http://dx.doi.org/10.1166/jno.2024.3596.

Full text
Abstract:
In order to know about the change features of leakage current during the pollution flashover process of composite insulators, the study of the pollution flashover test on composite insulator under the pollutional condition is presented in the artificial fog cabinet. The characteristics of leakage current waveforms in time-domain and frequency-domain are measured and analyzed during the test. The analysis results show that there is a strong correlation among the fundamental harmonic, the third harmonic and fifth harmonic. The characteristics of leakage current spectrum are represented by the ma
APA, Harvard, Vancouver, ISO, and other styles
7

BENISHEIKH, UMAR ALI, and Zulkurnain Abdul-Malek. "Leakage Current Harmonic Index as A Diagnostic Technique for Tool to Assess the Surface Condition Assessment of Aged Insulator Surface Under Varying Humidity." ELEKTRIKA- Journal of Electrical Engineering 23, no. 1 (2024): 141–47. http://dx.doi.org/10.11113/elektrika.v23n1.529.

Full text
Abstract:
Leakage current has been widely utilized as an effective means to monitor the pollution severity of outdoor insulators. The indices of the odd harmonic components of the leakage current have proven to be reliable indicators of insulator performance, particularly in the third to fifth harmonic orders. However, significant challenges exist in using these indices to monitor and classify the leakage current of aged insulators under varying harmonic and pollution conditions. This paper introduces the harmonic index K((3/(5+7) ) which employs third up to seventh odd harmonic component of the leakage
APA, Harvard, Vancouver, ISO, and other styles
8

Quan, Yu Sheng, Bo Yi, Shai Gen Han, and Zi Sen Ning. "Aging Characteristic Parameters Analysis and Experimental Study of MOA Varistor." Advanced Materials Research 805-806 (September 2013): 859–62. http://dx.doi.org/10.4028/www.scientific.net/amr.805-806.859.

Full text
Abstract:
This paper does aging test about zinc oxide varistor and collects the waveform data from the arrester before and after aging, then uses numerical calculation and FFT to analyze the waveform data. Through comparing the changes of characteristic parameters before and after aging such as power loss of varistor, leakage current and every harmonic current, this paper can get the relationship between varistor aging and leakage current, especially the changes of resistive fundamental and harmonic current after aging. Based on analysis and study of aging characteristic parameters of the arresters, it
APA, Harvard, Vancouver, ISO, and other styles
9

Sun, Jixing, Yongzhi Fan, Kun Zhang, Jiyong Liu, Xin Wang, and Shengchun Yan. "The Leakage Current Characteristics of High-Gradient MOA Plate and Its Heating Analysis with Coatings under High-Frequency Overvoltage." Coatings 13, no. 3 (2023): 497. http://dx.doi.org/10.3390/coatings13030497.

Full text
Abstract:
High-frequency overvoltage generated in railways results in explosions of Electric Multiple Units’ (EMUs) arrestors. To solve this problem, the leakage current characteristics and heat transfer process of high-gradient MOA plates under high-frequency overvoltage has been studied. The leakage current characteristics of arrestor plates under high-frequency voltage was obtained and the element distribution has been analyzed. Heat transfer distribution and the thermal properties of the Metal Oxide Arrestor (MOA) have been modelled. According to the results, for a given voltage, the higher the harm
APA, Harvard, Vancouver, ISO, and other styles
10

N., Suresh, and R. Samuel Rajesh Babu. "Reduction of Total Harmonic Distortion in Cascaded H-Bridge Inverter by Pattern Search Technique." International Journal of Electrical and Computer Engineering (IJECE) 7, no. 6 (2017): 3292. http://dx.doi.org/10.11591/ijece.v7i6.pp3292-3298.

Full text
Abstract:
Pattern Search technique can be used to find the solution for the optimization problem. In this paper, pattern search algorithm has been utilized to calculate the switching angles for the cascaded H-bridge inverter with the consideration of minimizing total harmonic distortion. Mathematical equations for the optimization problem were formulated by fourier analysis technique. Lower order harmonics such as third, fifth, seventh, ninth and eleventh order harmonics were taken into account to mitigate the total harmonic distortion of the inverter. Simulations have been carried out for thirteen leve
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Third harmonic resistive leakage current"

1

Junior, Milton Zanotti. "Contribuição à metodologia de avaliação dos pára-raios do sistema de transmissão de energia elétrica." Universidade de São Paulo, 2009. http://www.teses.usp.br/teses/disponiveis/86/86131/tde-24042009-154345/.

Full text
Abstract:
Os sistemas elétricos de potência estão sujeitos a diversos tipos de sobretensões que podem causar desligamentos ou avarias nos equipamentos elétricos que o compõe, comprometendo a continuidade do fornecimento de energia elétrica aos consumidores e impactando negativamente nos índices de qualidade. Um dos dispositivos mais importantes utilizados na proteção destes equipamentos são os pára-raios, os quais podem ser classificados, no sistema elétrico brasileiro, em função de sua tecnologia: a primeira, mais antiga, utiliza carboneto de silício (SiC), a segunda e mais atual utiliza óxido de zinco
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Third harmonic resistive leakage current"

1

Gondaliya, Jay B., Hemang Tailor, Umesh Soni, and Anil S. Khopkar. "Effect of Supply Harmonics on Measurement of 3rd Harmonic Resistive Leakage Current of Metal Oxide Surge Arrester." In 2024 IEEE 3rd International Conference on Electrical Power and Energy Systems (ICEPES). IEEE, 2024. http://dx.doi.org/10.1109/icepes60647.2024.10653584.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Yongqiang, Wang, Lu Fangcheng, Shang Jing, and Li Heming. "Influence of Power System¿s Harmonic Voltage and Interphase Interference to On-line Resistive Leakage Current monitoring of MOA." In The 2006 4th Asia-Pacific Conference on Environmental Electromagnetics. IEEE, 2006. http://dx.doi.org/10.1109/ceem.2006.258031.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Lange, Martin, Matthias Rolfes, Ronald Mailach, and Henner Schrapp. "Periodic Unsteady Tip Clearance Vortex Development in a Low Speed Axial Research Compressor at Different Tip Clearances." In ASME Turbo Expo 2017: Turbomachinery Technical Conference and Exposition. American Society of Mechanical Engineers, 2017. http://dx.doi.org/10.1115/gt2017-64256.

Full text
Abstract:
Since the early work on axial compressors the penalties due to radial clearances between blades and side walls are known and an ongoing focus of research work. The periodic unsteadiness of the tip clearance vortex, due to its interaction with the stator wakes, has only rarely been addressed in research papers so far. The current work presents experimental and numerical results from a four stage low speed research compressor modeling a state of the art compressor design. Time-resolved experimental measurements have been carried out at three different rotor tip clearances (gap to tip chord: 1.5%
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!