To see the other types of publications on this topic, follow the link: Tomografo.

Dissertations / Theses on the topic 'Tomografo'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Tomografo.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Fucci, Laura. "Caratterizzazione dosimetrica e di qualità immagine del tomografo Philips Brilliance ICT 256-slice." Master's thesis, Alma Mater Studiorum - Università di Bologna, 2015. http://amslaurea.unibo.it/8354/.

Full text
Abstract:
In questo lavoro, svolto presso l'Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (I.R.S.T.) (I.R.C.C.S) di Meldola, si sono studiate le caratteristiche di un tomografo Philips Brilliance iCT 256 strati, con l'obiettivo di individuare le variazioni di qualità delle immagini e di dose in funzione dei parametri di acquisizione dello strumento, al fine di una successiva ottimizzazione dei protocolli degli esami tomografici. Le valutazioni sono state fatte sul tomografo multistrato Philips mediante uso di diversi fantocci e dosimetri, seguendo le linee guida della pubblicazione per il controllo di qualità in tomografia computerizzata dell'International Atomic Energy Agency (IAEA). Si è utilizzato il fantoccio Catphan per la caratterizzazione della qualità dell'immagine, acquisendo immagini sia in modalità assiale che spirale e variando parametri di acquisizione quali spessore di strato, kV, mAs e pitch. Per le varie combinazioni di questi parametri sono state misurate, mediante l'utilizzo dei software ImageJ ed ImageOwl, grandezze oggettive quali risoluzione spaziale, risoluzione a basso contrasto e rumore dell'immagine acquisita. Due fantocci di polimetilmetacrilato (PMMA) head e body sono serviti, insieme ad una camera a ionizzazione di tipo pencil, per la misura di indici di dose per la tomografia computerizzata (CTDI). L'irraggiamento di questi strumenti è stato effettuato a diversi valori di tensione del tubo radiogeno e ha permesso di confrontare i valori CTDI misurati con quelli forniti dal tomografo. Si sono quindi calcolate le dosi efficaci di alcuni protocolli della macchina per poi confrontarle con livelli di riferimento diagnostici (DRL), strumenti utilizzati con l'obiettivo di raggiungere valori di dose adeguati per lo scopo clinico dell'esame. Come ulteriore valutazione dosimetrica, si è utilizzato il fantoccio antropomorfo Rando, in cui sono stati inseriti dei dosimetri a termoluminescenza (TLD) per la misura della dose organo. Dai risultati si osserva un andamento inversamente proporzionale tra tensione del tubo radiogeno e contrasto dell'immagine. Impostando valori alti di kV si ottiene però un'immagine meno rumorosa. Oltre alla tensione del tubo, si è valutato come anche lo spessore di strato e la corrente influiscano sul rumore dell'immagine. I risultati ottenuti dimostrano che i valori dei parametri oggettivi di qualità delle immagini rientrano nei limiti di attendibilità, così come i valori di CTDI visualizzati dal tomografo. Lo studio della dipendenza di questi parametri oggettivi dalle impostazione di scansione permette di ottimizzare l'acquisizione TC, ottenendo un buon compromesso fra dose impartita e qualità dell'immagine.
APA, Harvard, Vancouver, ISO, and other styles
2

Da, Vià Luigi. "Applicazione di un tomografo a resistenza elettrica allo studio della miscelazione in reattori bifase agitati meccanicamente." Master's thesis, Alma Mater Studiorum - Università di Bologna, 2011. http://amslaurea.unibo.it/2560/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Rosa, Alessandro. "Caratteristiche dei radiofarmaci utilizzati per le indagini PET." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2017. http://amslaurea.unibo.it/13260/.

Full text
Abstract:
I radiofarmaci sono radionuclidi o composti chimici contenenti radionuclidi. Questi preparati radioattivi rispettano tutte le normative previste dalla farmacopea ufficiale (F.U.) per la somministrazione nell'uomo. Un rilevante numero di radiofarmaci sono da tempo utilizzati a scopo diagnostico e terapeutico nei reparti di medicina nucleare.L’avvento della tomografia ad emissione di positroni (PET), tecnica diagnostica per le immagini che fornisce informazioni di tipo funzionale-metabolica attraverso l’utilizzo di radionuclidi con breve emivita, ha incrementato la produzione di radionuclidi.Nel presente elaborato di tesi sono state analizzate le caratteristiche e il relativo campo di applicazione dei principali radiofarmaci utilizzati per le indagini PET. Per ognuno di essi è stato descritto il meccanismo d’azione e i principali utilizzi. I principali campi d’applicazione trattati sono quello Oncologico, Cardiologico e Neurologico. Oltre alle caratteristiche dei vari radiofarmaci sono state evidenziate anche le normative riguardanti le norme di buona preparazione dei radiofarmaci e i principali metodi di protezione dalle radiazioni.
APA, Harvard, Vancouver, ISO, and other styles
4

Masetti, Simone <1970&gt. "Sviluppo di un tomografo multi-energy per lo studio pre-clinico di nuove metodiche diagnostiche finalizzate al riconoscimento precoce della patologia tumorale." Doctoral thesis, Alma Mater Studiorum - Università di Bologna, 2008. http://amsdottorato.unibo.it/841/.

Full text
Abstract:
A new multi-energy CT for small animals is being developed at the Physics Department of the University of Bologna, Italy. The system makes use of a set of quasi-monochromatic X-ray beams, with energy tunable in a range from 26 KeV to 72 KeV. These beams are produced by Bragg diffraction on a Highly Oriented Pyrolytic Graphite crystal. With quasi-monochromatic sources it is possible to perform multi-energy investigation in a more effective way, as compared with conventional X-ray tubes. Multi-energy techniques allow extracting physical information from the materials, such as effective atomic number, mass-thickness, density, that can be used to distinguish and quantitatively characterize the irradiated tissues. The aim of the system is the investigation and the development of new pre-clinic methods for the early detection of the tumors in small animals. An innovative technique, the Triple-Energy Radiography with Contrast Medium (TER), has been successfully implemented on our system. TER consist in combining a set of three quasi-monochromatic images of an object, in order to obtain a corresponding set of three single-tissue images, which are the mass-thickness map of three reference materials. TER can be applied to the quantitative mass-thickness-map reconstruction of a contrast medium, because it is able to remove completely the signal due to other tissues (i.e. the structural background noise). The technique is very sensitive to the contrast medium and is insensitive to the superposition of different materials. The method is a good candidate to the early detection of the tumor angiogenesis in mice. In this work we describe the tomographic system, with a particular focus on the quasi-monochromatic source. Moreover the TER method is presented with some preliminary results about small animal imaging.
APA, Harvard, Vancouver, ISO, and other styles
5

Cepparulo, Martina. "Analisi del processo di miscelazione in sistemi solido-liquido agitati meccanicamente." Master's thesis, Alma Mater Studiorum - Università di Bologna, 2021.

Find full text
Abstract:
I processi di miscelazione sono solitamente classificati in base al tipo di materiale da analizzare e si dividono in miscelazione solido-liquido, gas-liquido e liquido-liquido. L’operazione di miscelazione solido-liquido, in serbatoi agitati meccanicamente, è un'operazione industriale molto diffusa, ampiamente utilizzata nelle industrie chimiche, alimentari, petrolifere, farmaceutiche ed elettriche. Nell’ambito della miscelazione di sistemi solido-liquido, l’agitazione del sistema influisce sulla dinamica di dispersione, sospensione e dissoluzione della fase solida, e i regimi che si instaurano dipendono dalla geometria del sistema, oltre che essere influenzati dalle proprietà fisiche delle due fasi. Dunque, l’obiettivo principale del processo di miscelazione solido-liquido è realizzare una dispersione di solidi in fase liquida, lo slurry, appropriata per il raggiungimento del grado di omogeneità desiderato. Per questo scopo, lo studio condotto si propone di monitorare i regimi di flusso di tali sistemi in un serbatoio agitato meccanicamente da girante pitched-blade turbine (PBT), al variare dell’intensità di agitazione e della concentrazione della fase dispersa, utilizzando come strumento di indagine un tomografo a resistenza elettrica (ERT). Per il monitoraggio di sistemi in serbatoi agitati, attraverso l’impiego dell’ ERT, si propone una procedura di acquisizione ed una metodologia di trattamento dati, studiate specificamente per il sistema in analisi.
APA, Harvard, Vancouver, ISO, and other styles
6

Bojková, Eva. "Design počítačového tomografu." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2009. http://www.nusl.cz/ntk/nusl-228556.

Full text
Abstract:
The graduation thesis is engaged in the design of computed tomography (CT). It is a piece of medical equipment which helps to define the diagnosis of a patient. The first part of the project is a research into contemporary stage and production of CT systems. Consequently the new design of computed tomography is designed in a way to maximise ergonomical, technical and aesthetic quality.
APA, Harvard, Vancouver, ISO, and other styles
7

Ronzová, Gabriela. "Design počítačového tomografu." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2013. http://www.nusl.cz/ntk/nusl-230498.

Full text
Abstract:
The presented master thesis concerns an own design concept of a CT scanner that meet the basic technical, ergonomical and social requirements and also brings a new look and shape as solution to the main topic.
APA, Harvard, Vancouver, ISO, and other styles
8

Kamakura, Tatiana Paula Alvarenga de Carvalho. "Avaliação da ventilação mecânica controlada a pressão utilizando-se a técnica de tomografia por impedância elétrica durante anestesia geral em cães." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/10/10137/tde-04082014-133218/.

Full text
Abstract:
A hipoventilação secundária ao procedimento anestésico é comum na prática anestésica, e, sendo assim, o emprego de técnicas de ventilação mecânica é adotado como forma de minimizar e/ou evitar os efeitos deletérios da hipoventilação. Porém, o uso de ventiladores mecânicos não é isento de risco, e atelectasias podem se formar mesmo quando são utilizados. Para análise em tempo real do pulmão, a técnica de tomografia por impedância elétrica vem sendo empregada em conjunto com outros meios de monitoração, tendo se demonstrado um meio útil de avaliação da ventilação pulmonar de maneira não invasiva, passível de ser utilizada à beira do leito e sem emissão de radiação. Estudos utilizando o tomógrafo de impedância elétrica em cães são escassos. O objetivo desse trabalho foi avaliar a ventilação de cães submetidos à anestesia inalatória e à ventilação mecânica utilizando a técnica de tomografia por impedância elétrica. Foram utilizados onze cães com peso superior a 16 kg e classificados como baixo risco anestésico (ASA I ou II). Os animais receberam acepromazina e meperidina como medicação pré-anestésica, propofol como indutor e isofluorano na manutenção da anestesia. Foram mantidos em ventilação mecânica controlada a pressão, com FiO2 de 0,6 e pressão de pico de 10 cmH2O durante os primeiros 90 minutos de anestesia. Foram então realizadas manobras de recrutamento alveolar e instituição de pressão positiva ao final da expiração (PEEP) de 5 cmH2O, e os animais foram avaliados por mais 35 minutos. Os parâmetros foram avaliados 30, 60 e 90 minutos após a indução da anestesia e 5 e 35 minutos após o recrutamento e instituição da PEEP. Apesar de não ter havido diferença estatisticamente significativa nos parâmetros de oxigenação e distribuição da ventilação, foi visível a melhora clínica e nas curvas de oxigenação e impedância. As curvas de impedância geradas a partir dos dados obtidos pelo tomógrafo de impedância elétrica acompanharam as curvas de melhora na oxigenação. O fato de, no estudo, terem sido utilizados animais hígidos e submetidos à ventilação mecânica e FiO2 de 0,6 desde o início pode ter contribuído para não ter havido melhora estatisticamente significativa, embora clinicamente visível. As manobras de recrutamento utilizadas também foram conservadoras em comparação aos outros trabalhos realizados. Infere-se que, se utilizássemos animais doentes e com FiO2 de 1, poderíamos ter obtido um grau maior de atelectasias nos primeiros 90 minutos de anestesia e/ou, se tivéssemos utilizado manobras de recrutamento menos conservadoras, poderíamos ter obtidos melhora estatisticamente significativa após as manobras e instituição da PEEP. A tomografia de impedância elétrica parece ser um bom meio de monitoração do pulmão em tempo real em cães submetidos à anestesia inalatória.
Hypoventilation secondary to anesthesia is common and, therefore, the use of mechanical ventilation techniques is adopted in order to minimize and/or prevent the deleterious effects of hypoventilation. However, the use of mechanical ventilators has risks, and atelectasis can develop even when they are used. For real-time analysis of the lung, the technique of electrical impedance tomography has been used in conjunction with other means of monitoring, having demonstrated to be useful for assessing pulmonary ventilation in a noninvasively way, and also can be used at the bedside and without radiation emission. There are not many studies using electrical impedance tomography in dogs. The aim of this study was to evaluate the ventilation of dogs subjected to inhalation anesthesia and mechanical ventilation using the technique of electrical impedance tomography. We used eleven dogs weighing more than 16 kg and classified as low anesthetic risk (ASA I or II). The animals were premedicated with acepromazine and meperidine, anesthesia was induced with propofol and maintained with isoflurane. Ventilation was then instituted with FiO2 of 0.6 and peak pressure of 10 cm H2O during the first 90 minutes of anesthesia. Alveolar recruitment maneuvers were realized and pressure positive end- expiratory pressure (PEEP) of 5 cmH2O was initiated. The animals were evaluated for more 35 minutes then. The parameters were measured at 30, 60 and 90 minutes after induction of anesthesia and 5 and 35 minutes after recruitment. Although there was no statistically significant difference in the parameters of oxygenation and ventilation distribution, clinical improvement was visible as was the oxygenation and impedance curves. The impedance curves generated from the data obtained with the electrical impedance tomograph followed the improvement in oxygenation curves. The fact that in this study we used healthy animals undergoing mechanical ventilation with FiO2 of 0.6 right from the beginning, may have contributed to no improvement statistically significant but clinically visible. Recruitment maneuvers used were also conservative in comparison to other papers. We think that, if we used animals and patients with FiO2 of 1, we could have obtained a higher degree of atelectasis in the first 90 minutes of anesthesia and/or, if we had used less conservative recruitment maneuvers, we could have obtained statistically significant improvement after maneuvers and institution of PEEP. The electrical impedance tomography seems to be a good means of real time monitoring the lung of dogs undergoing inhalation anesthesia.
APA, Harvard, Vancouver, ISO, and other styles
9

Vařeka, Karel. "Korelativní tomografie." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2021. http://www.nusl.cz/ntk/nusl-443242.

Full text
Abstract:
Předložená diplomová práce se zabývá korelativním přístupem multimodální analýzy struktur prokovování s různým rozlišením. Výzkum je součástí mezinárodního projektu týkajícího se charakterizace poruch zmíněných struktur, které jsou implementovány v polovodičových zařízeních. Kombinace korelativní mikroskopie a tomografie technikami NanoXCT, FIB-SEM (EDS), FIB-SIMS a AFM byla navržena k zavedení opakovatelného pracovního postupu. Tomografie fokusovaným iontovým svazkem je metoda přesného odprašování v řezech, která mimo jiné v každém průřezu získává cenné snímky s vysokým rozlišením (FIB-SEM) nebo mapy chemického složení (FIB-SIMS). Následující transformace obrazu umožňuje identifikaci defektů jako funkci hloubky ve struktuře. Práce dále věnuje pozornost metodám sjednocení obrazů za účelem optimální prezentace získaných dat.
APA, Harvard, Vancouver, ISO, and other styles
10

Pimenta, Wanderson Maia. "Tomografia experimental de estados quânticos:: impIementação de tomografia mínima." Universidade Federal de Minas Gerais, 2010. http://hdl.handle.net/1843/IACO-84RRCW.

Full text
Abstract:
This work has as a main goal the implementation of the experimental minimal quantum tomography in spatial variables using a spatial light modulator. To produce the two photons states entangled in spatial variables we use the properties of the photons produced by Spontaneous Parametric Down Conversion (SPDC) and double slits. A theoricaldescription was necessary for the understanding of the minimal tomography method. Four states which describe a tetrahedron in the Bloch sphere were chosen and associated to these states, were built four operators, making it a POVM set for tomography. For the experimental implementation of these operators, it took two calibrations of the spatial light modulator. Values of grayscales and polarization angles of input and output polarizers were determined in order to apply dierent phases and/or specific amplitude diferences between the beams that pass through each slit path. Thus, through the studyof minimal tomography and the knowledge of the operation of the modulator and their calibration, it was possible to experimentally perform the minimal quantum tomography for one and two qubits in spatial variables.
Este trabalho tem como principal objetivo a implementação experimental da tomografia mínima utilizando um modulador espacial de luz. Para tal fim, utilizamos as propriedades dos fótons produzidos pela conversão paramétrica descendente bem como a geração de estados discretos e multidimensionais utilizando fendas múltiplas. Uma descrição teórica foi necessária para o entendimento do método da tomografia mínima. Foram escolhidos quatro estados que descrevem um tetraedro na esfera de Bloch e associados a estes estados, foram construídos quatro projetores, constituindo assim um POVM para a tomografia. Para a implementação experimental destes projetores, foram necessárias duas calibrações do modulador espacial. Valores de escalas de cinza e polarizações de entrada e saída foram determinados com o objetivo de aplicar diferenças de fase e/ou amplitudes específicas entre os feixes que passam por fendas múltiplas. Assim, através do estudo da tomografia mínima e do conhecimento do funcionamento do modulador espacial e suas respectivas calibrações, foi possível realizar experimentalmente as tomografias para um e dois qubits.
APA, Harvard, Vancouver, ISO, and other styles
11

Almenara, Díaz Carlos. "Tomografía Axial Computarizada." Bachelor's thesis, Universidad Ricardo Palma. Programa Cybertesis PERÚ, 2007. http://cybertesis.urp.edu.pe/urp/2007/almenara_c/html/index-frames.html.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Glionna, Giuseppe. "Tomografia de hemácias." Universidade Federal de Minas Gerais, 2009. http://hdl.handle.net/1843/ESCZ-7ZFFXS.

Full text
Abstract:
Transparent objects (phase objects) render visible in a bright-eld optical microscope, if the microscope is defocused. In fact, a defocused bright-eld optical microscope is equivalent to a phase contrast microscope, presenting advantages over the conventional one, as it will be discussed in this thesis. Defocusing causes a phase difference between the transmitted light (non-diffracted) and the light diffracted bythe phase object, which when combined at the detection plane due to light interference, renders the object visible, with an image contrast different than zero. This effect was demonstrated in our laboratory in several articles and previous thesis [1-7]. In this thesis, we improved our optical model of defocusing microscopy, such that its validity was extended to any defocusing, including asymptotically large defocusing,and for larger diffaction wavenumbers. We obtain theoretical expressions for the contras of phase objects composed by one and by two parallel interfaces. In the limit of small defocusing and small diffraction wavenumbers, from the time averaged contrast, we can obtain information about the equilibrium shape of (RBC) red blood cells (erythrocytes), as previously demonstrated [4]. Our new expressions areimportant to establish a relationship between defocused image contrast fluctuations and surface height uctuations on RBCs. With our new optical model we show that by scanning the microscope objective focal plane position (zf ), and since the RBC surfaces are at different positions in relation to the z-axis, there diffracted light are affected by different phase differences, such that it surface can be distinguished by using defocusing microscopy. This fact allows us to study the properties of each interface separately. For fluctuations with wavenumbers larger than 1 um -1, one can approximate the RBC central region by parallel planes, and apply the optical model for two interfaces developed in this thesis. By using the recently developed elastic model by Auth et al. [8], which takes into account the coupling between the lipid bilayer and the spectrin cytoskeleton (and also uses the approximation of parallel planes for the RBC surfaces) and our optical model, we have obtained a very good t for the experimental data. From this t we have obtained the values for the lipid bilayer curvature modulus, for the cytoskeleton shear modulus and for the effective temperature. The RBC height uctuations are not only of thermal origin. Another contribution comes from the conversion of chemical energy into mechanical work driven by ATP (adenosine triphosphate, the cell's combustible) [9,10]. These non-equilibrium effects are lumped into a single parameter, namely the effectivetemperature introduced in an ad-hoc manner. This effect is still contoversial in the literature [11]. We also studied the relaxation of RBC height uctuations through the time autocorrelation function of contrast fluctuations. This relaxation is dictated by the elasticity of the lipid bilayer and the spectrin cytoskeleton, and by the flow of the cytoplasm through the narrow gap of width d ~ 20 to 30 nm, between the bilayer and the cytoskeleton. From the t of this theory to our data, we obtained a gap-width d = 21 +- 1 nm. We showed that defocusing microscopy is an useful and trustable technique to study height proles and static and dynamic roughness of interfaces in a transparent multilayered material, like membranes of living cells.
Objetos transparentes (objetos de fase) se tornam visíveis em um microscópio óptico operando em campo-claro, se o microscópio estiver desfocalizado operando em campo-claro é equivalente a um microscópio de contraste de fase, apresentando vantagens que serão discutidas nesta tese, em relação ao microscópio de contraste de fase convencional. A desfocalização introduz uma diferença de fase entre a luz transmitida (não-difratada) e a luz difratada pelo objeto, que ao serem recombinadas no plano de detecção e devido à interferência entre essas luzes, faz com que o objeto transparente se torne visível, com um contraste da imagem diferente de zero. Isto foi demonstrado em nosso laboratório em artigos e teses anteriores. Nesta tese, melhoramos o modelo ótico de microscopia de desfocalização, para que ele fosse válido para qualquer desfocalização, inclusive no limite assintótico de grandes desfocalizações e para maiores números de onda de difração. Obtivemos expressões teóricas para o contraste de objetos de fase compostos por uma e por duas interfaces paralelas. No limite de pequenas desfocalizações e pequenos números de onda de difração, da média temporal do contraste, podemos obter a forma de equilíbrio de hemácias, como demonstrado em publicação anterior deste laboratório. Nossa nova expressão é importante para estabelecer uma relação entre flutuações de contraste e flutuações na altura das superfícies da hemácia. Com este novo modelo óptico, nós mostramos que ao fazer uma varredura na posição do plano focal da objetiva (zf), como as superfícies das hemácias estão em posições diferentes em relação à z, elas são afetadas de fases diferentes e, portanto, podem ser distinguidas nesta técnica de microscopia de desfocalização. Este fato nos permite estudar as propriedades de cada superfície separadamente. Para flutuações com números de ondas maiores que 1 m-1, podemos aproximar a região central da hemácia como planos paralelos e aplicar o modelo óptico para objetos de fase com duas interfaces desenvolvidas nesta tese. Usando o modelo elástico recente de Auth et al, que leva em conta o acoplamento entre bicamada lipídica e o citoesqueleto de espectrina (que também considera as superfícies de hemácias como planos paralelos) e nosso modelo óptico, obtivemos um ótimo ajuste para os dados experimentais. Deste ajuste obtivemos os valores para o módulo de curvatura da bicamada, o módulo de cisalhamento do citoesqueleto e para a temperatura efetiva. As flutuações de altura em hemácia não são somente de origem térmica. Outra contribuição vem da conversão de energia química em trabalho mecânico nas superfícies, mediada por ATP (adenosina trifostato o combustível das células) Estes efeitos fora do equilíbrio são reduzidos a único parâmetro, qual seja a temperatura efetiva introduzida de uma maneira ad-hoc. Este efeito ainda é motivo de controvérsia na literatura. Estudamos também a relaxação destas flutuações analisando a função de auto-correlação temporal do contraste. Esta relaxação depende da elasticidade da bicamada lipídica e citoesqueleto de espectrina e do escoamento do citoplasma através do canal estreito, d espessura d da ordem de 20 a 30 nm, entre bicamada e o citoesqueleto. Do ajuste da teoria aos nossos dados obtivemos d=21±1nm. Mostramos que a técnica de microscopia de desfocalização é uma técnica de microscopia óptica bastante útil e confiável para o estudo do perfil e rugosidades dinâmicas e estática de interfaces em um material transparente em multicamadas, como membranas de células biológicas.
APA, Harvard, Vancouver, ISO, and other styles
13

Moura, Priscila Padilha. "Caracterização morfológica de arco zigomático, maxila e mandíbula em indivíduos com disostose mandibulofacial." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/61/61132/tde-13062017-112819/.

Full text
Abstract:
Introdução: as disostoses mandibulofaciais representam um grupo de condições geneticamente heterogêneas, caracterizado principalmente por hipoplasia de arco zigomático, hipoplasia mandibular e anomalias de orelhas. Objetivos: caracterizar a morfologia craniofacial de diferentes tipos de disostose mandibulofacial e investigar as alterações de mandíbula, maxila, arco zigomático e côndilo mandibular, meio de avaliação radiológica. Casuística e métodos: fizeram parte deste estudo 54 indivíduos (sendo 25 do sexo feminino e 13 do sexo masculino), com diagnóstico de disostose mandibulofacial definido por profissionais da Seção de Genética Clínica e Biologia Molecular do Hospital de Reabilitação de Anomalias Craniofaciais. Os indivíduos foram submetidos à atualização dos dados genético-clínicos e avaliação radiológica, por meio de tomografia computadorizada (helicoidal ou de feixe cônico). Para a análise morfológica, as imagens adquiridas foram reconstruídas em terceira dimensão e as estruturas craniofaciais segmentadas no software Mimics para auxiliar na descrição das alterações no arco zigomático, maxila e mandíbula A análise dos dados clínicos e morfológicos foi descritiva e em forma de tabela. Resultados: trinta e dois tinham diagnóstico genético-clínico de síndrome de Treacher-Collins, sete de disostose mandibulofacial tipo Bauru, quatro de disostose mandibulofacial tipo Guion-Almeida, um de disostose mandibulofacial com alopecia e dez de disostose mandibulofacial a esclarecer. A análise morfológica mostrou hipoplasia de osso e arco zigomático, maxila e mandíbula em todos os indivíduos avaliados e com alta variabilidade fenotípica. No entanto, os indivíduos com síndrome de Treacher Collins apresentaram um espectro fenotípico mais grave, foram observadas fissuras ósseas de Tessier número 6, 7 e 8, alterações nos côndilos mandibulares, processos coronoides, ramo e corpo mandibular. A disostose mandibulofacial com alopecia mostrou agenesia da porção temporal do arco zigomático, fissura óssea de Tessier número 8 (processo zigomático do osso temporal), mandíbula hipoplásica e assimétrica mandibular, os côndilos foram largos e os processos coronoides hipoplásicos. Na disostose mandibulofacial tipo Guion-Almeida foi observado fissura óssea de Tessier número 7, assimetria de face, hipoplasia mandibular com alterações de côndilo e anomalia de processo coronoide, a disostose mandibulofacial tipo Bauru apresentou uma hipoplasia de maxila bem acentuada com arco zigomático fino e hipoplásico, hipoplasia mandibular, côndilos hipoplásicos e alterações no processo coronoide e os casos com disostose mandibulofacial a esclarecer apresentaram hipoplasia de face média e mandíbula de grau variável e três casos apresentaram alterações esqueléticas, um caso sugere síndrome cerebrocostomandibular, um caso sobrepõe síndrome de Treacher Collins, dois casos sobrepõem os sinais clínicos de disostose mandibulofacial tipo Guion-Almeida e os outros três casos permanecem não esclarecidos. Conclusão: os achados na síndrome de Treacher Collins são mais graves dentro do grupo e os achados radiológicos da disostose mandibulofacial tipo Guion-Almeida sobrepõem aos observados na síndrome de Treacher Collins, os achados na disostose mandibulofacial tipo Bauru são mais leves que os outros grupos e a disostose mandibulofacial com alopecia apresenta um fenótipo peculiar e para os casos de disostose mandibulofacial não esclarecidos, a análise molecular é necessária para auxiliar no diagnóstico
Introduction: Mandibulofacial dysostoses are a genetically heterogeneous group of conditions characterized mainly by hypoplasia of the zygomatic arch, mandibular hypoplasia and ear anomalies. Purpose: Characterize the craniofacial morphology of different types of mandibulofacial dysostosis and investigate the anomalies in zygomatic arch, mandible, maxilla and mandibular condyle, by means of radiological evaluation. Methods: This study included 54 patients (with 25 female and 13 male) diagnosed with mandibulofacial dysostosis defined by professionals from Clinical Genetics Section and Molecular Biology by Hospital for Rehabilitation of Craniofacial Anomalies. The subjects underwent updating of clinical genetic and radiological evaluation by computed tomography (helical scan or cone beam). For morphological analysis, the acquired images were reconstructed in three dimensions and craniofacial structures were segmented in the Mimics software to assist in the description of the changes in the zygomatic arch, maxilla and mandible The analysis of clinical and morphological data was descriptive and in table form. Results: Thirty-two had genetic-clinical diagnosis of Treacher-Collins syndrome, 7 dysostosis mandibulofacial type Bauru, 4 dysostosis mandibulofacial Guion-Almeida type, 1 dysostosis mandibulofacial with alopecia and 10 with dysostosis mandibulofacial not defined.Morphological analysis showed hypoplasia of bone and zygomatic arch, maxilla and mandible in all evaluated individuals with high phenotypic variability. However, individuals with Treacher Collins syndrome presented in a more severe phenotype spectrum, Tessier cleft number were observed 6, 7 and 8, changes in mandibular condyles coronoides processes and mandibular ramus and body. The mandibulofacial dysostosis with alopecia showed agenesis of the temporal portion of the zygomatic arch, Tessier cleft number 8 (zygomatic process of the temporal bone), mandible hypoplastic and asymmetric, the condyles were broad and coronoides process hypoplastic. Mandibulofacial dysostosis Guion-Almeida type showed Tessier cleft number 7, facial asymmetry, mandibular hypoplasia with changes of condyle and coronoid process of anomaly, the mandibulofacial dysostosis type Bauru showed a well marked mandible hypoplasia with zygomatic arch hypoplastic and thin, mandibular hypoplasia, hypoplastic condyles and changes in the coronoid process and the cases with mandibulofacial dysostosis not defined had hypoplastic midface and varying degree of mandible and three cases showed skeletal changes, one case suggests cerebrocostomandibular syndrome, one case overlaps Treacher Collins syndrome, two cases overlapping clinical signs of dysostosis mandibulofacial Guion Almeida-type and the other three cases remain unclear. Conclusion: the radiological findings in Treacher Collins syndrome were more severe in the groups The radiological findings of mandibulofacial dysostosis Guion-Almeida type overlap those observed in Treacher Collins syndrome, the findings in mandibulofacial dysostosis Bauru type were lighter than the other groups and mandibulofacial dysostosis with alopecia presents a peculiar phenotype and for cases of dysostosis mandibulofacial not defined, molecular analysis is needed to aid in the diagnosis
APA, Harvard, Vancouver, ISO, and other styles
14

Pernas, Canadell Juan Carlos. "Significado de la visualización de la vena central de la glándula suprarrenal en la tomografía computarizada con contraste intravenoso." Doctoral thesis, Universitat Autònoma de Barcelona, 2020. http://hdl.handle.net/10803/672023.

Full text
Abstract:
Els estudis rutinaris mitjançant TC per diferents causes detecten lesions adenomatoses com troballa incidental en un percentatge significatiu dels estudis. Una situació clínica habitual és la detecció d’un nòdul suprarrenal en un estudi toràcic o abdominal rutinari amb contrast intravenós realitzat a la fase venosa (als 70 segons aproximadament després de la injecció de la mateixa), de manera que establir el diagnòstic d’adenoma en aquest tipus d’exploració és difícil ja que les característiques de la imatge es solapen amb les de les metàstasis i altres lesions suprarrenals. En base als criteris anatomopatològics de Weiss en què estableix que l’absència d’invasió vascular venosa és un criteri de benignitat d’una lesió suprarenal, aquesta tesi pretén establir el valor predictiu positiu de la visualització de la vena central de la glàndula suprarrenal en la TC amb contrast intravenós d’correspondre a una lesió suprarrenal adenomatosa benigna en els pacients als quals es realitza l’exploració per qualsevol motiu. Per a això s’ha determinat en un grup de 100 lesions suprarrenals identificades en estudis rutinaris la presència d’aquest signe radiològic. D’altra banda, es va seleccionar un grup de 90 lesions observades en estudis rutinaris en què es va visualitzar la vena central de la glàndula suprarrenal en la TC amb contrast intravenós correl.lacionant-les amb el seu diagnòstic final confirmat per la seva evolució o estudi histològic. La visualització de la vena central de la glàndula suprarrenal va mostrar una prevalença del 61% i va oferir una sensibilitat del 66%, una especificitat del 80%, un valor predictiu positiu del 97% i un valor predictiu negatiu del 21% per al diagnòstic de lesió adenomatosa. La visualització de la vena central de la glàndula suprarrenal en lesions suprarrenals incidentals ofereix un alt valor predictiu positiu que aquestes lesions siguin d’estirp adenomatosa, tant en pacients oncològics com no oncològics, però, l’absència de visualització de la vena central de la glàndula suprarrenal no permet determinar la naturalesa de la lesió.
Los estudios rutinarios mediante TC por diferentes causas detectan lesiones adenomatosas como hallazgo incidental en un porcentaje significativo de los estudios. Una situación clínica habitual es la detección de un nódulo suprarrenal en un estudio torácico o abdominal rutinario con contraste intravenoso realizado en la fase venosa (a los 70 segundos aproximadamente después de la inyección del mismo), por lo que establecer el diagnóstico de adenoma en este tipo de exploración es difícil ya que las características de la imagen se solapan con las de las metástasis y otras lesiones suprarrenales. En base a los criterios anatomopatológicos de Weiss en los que establece que la ausencia de invasión vascular venosa es un criterio de benignidad de una lesión suprarrenal, esta tesis pretende establecer el valor predictivo positivo de la visualización de la vena central de la glándula suprarrenal en la TC con contraste intravenoso de corresponder a una lesión suprarrenal adenomatosa benigna en los pacientes a los que se realiza la exploración por cualquier motivo. Para ello se ha determinado en un grupo de 100 lesiones suprarrenales identificadas en estudios rutinarios la presencia de este signo radiológico. Por otro lado, se seleccionó un grupo de 90 lesiones observadas en estudios rutinarios en las que se visualizó la vena central de la glándula suprarrenal en la TC con contraste intravenoso correlacionandolas con su diagnóstico final confirmado por su evolución o estudio histológico. La visualización de la vena central de la glándula suprarrenal mostró una prevalencia del 61% y ofreció una sensibilidad del 66%, una especificidad del 80%, un valor predictivo positivo del 97% y un valor predictivo negativo del 21% para el diagnóstico de lesión adenomatosa. La visualización de la vena central de la glándula suprarrenal en lesiones suprarrenales incidentales ofrece un alto valor predictivo positivo de que estas lesiones sean de estirpe adenomatosa, tanto en pacientes oncológicos como no oncológicos, sin embargo, la ausencia de visualización de la vena central de la glándula suprarrenal no permite determinar la naturaleza de la lesión.
Routine CT studies for different causes detect adenomatous lesions as an incidental finding in a significant percentage of the studies. A common clinical situation is the detection of an adrenal nodule in a routine thoracic or abdominal study with intravenous contrast performed in the venous phase (approximately 70 seconds after injection), therefore establishing the diagnosis of adenoma in this this type of examination is difficult since the image characteristics overlap with those of metastases and other adrenal lesions. Based on the Weiss pathological criteria in which it is established that the absence of venous vascular invasion is a benign criterion of an adrenal lesion, this thesis aims to establish the positive predictive value of visualization of the central vein of the adrenal gland in the Intravenous contrast-enhanced CT to correspond to a benign adrenal lesion in patients undergoing exploration for any reason. For this, the presence of this radiological sign has been determined in a group of 100 adrenal lesions identified in routine studies. On the other hand, a group of 90 lesions observed in routine studies in which the central vein of the adrenal gland was visualized on CT with intravenous contrast were selected, correlating them with their final diagnosis confirmed by their evolution or histological study. Visualization of the central vein of the adrenal gland showed a prevalence of 61% and offered a sensitivity of 66%, a specificity of 80%, a predictive positive value of 97% and a negative predictive value of 21% for the diagnosis of adenomatous lesion. Visualization of the central vein of the adrenal gland in incidental adrenal lesions offers a high predictive positive value that these lesions are adenomatous, both in oncological and non-oncological patients, however, the absence of visualization of the central vein of the adrenal gland it does not allow to determine the nature of the lesion.
Universitat Autònoma de Barcelona. Programa de Doctorat en Medicina
APA, Harvard, Vancouver, ISO, and other styles
15

Perlin, Lourenço Panosso. "Tomografia ultrassônica em concreto." Florianópolis, SC, 2011. http://repositorio.ufsc.br/xmlui/handle/123456789/95463.

Full text
Abstract:
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2011
Made available in DSpace on 2012-10-26T02:00:55Z (GMT). No. of bitstreams: 1 291197.pdf: 5731903 bytes, checksum: a2652036a9f0348e1c65fbf72f41df65 (MD5)
Nessa pesquisa efetua-se uma revisão bibliográfica da técnica ultrassônica convencional, demonstrando suas capacidades e limitações na localização de não homogeneidades no concreto. A proposta dessa dissertação é utilizar a técnica tomográfica aplicada com os resultados dos equipamentos já disponíveis para as leituras ultrassônicas no concreto, de modo a melhorar consideravelmente o potencial de visualização dessas não homogeneidades. Para tal, a tomografia também é estudada e adaptada ao uso com o ultrassom. Como é indispensável a utilização de programas de computador para a resolução do problema tomográfico, também nessa pesquisa é efetuada a implementação computacional da tomografia adaptada para o uso do ultrassom. Com o programa TUCon implementado e numericamente verificado, vários ensaios experimentais são executados em corpos de prova de concreto sem armadura e com diferentes não homogeneidades internas conhecidas. Pesquisadores internacionais afirmam que a técnica da tomografia ultrassônica em concreto tem grandes potencialidades para ser utilizada na reconstituição de seções internas de concreto para identificação de não homogeneidades. Através de ensaios experimentais, os resultados dessa dissertação reafirmam tal constatação.
This work presents a review of the ultrasonic pulse velocity method, showing its capacity and limitations for internal flaws identification in plain concrete members. To further improve this ability, the main goal of this work is to use the tomography technique with the results from of conventional ultrasonic equipment already available. Thus, the tomography theory is also presented and adapted to be used with ultrasound equipment. Since is necessary to solve the system of equations yielded by the tomography technique, a software was developed in this work, called TUCon. After TUCon has been numerically checked, several experiments were performed on plain concrete specimens with known internal flaws. International researchers agree that ultrasonic tomography technique has great potential to be used in the reconstitution of internal sections of concrete members and to identify flaws. The experiments performed in this work endorse this statement.
APA, Harvard, Vancouver, ISO, and other styles
16

Jeništa, Petr. "Optimalizace metody měření magnetické susceptibility." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2011. http://www.nusl.cz/ntk/nusl-218874.

Full text
Abstract:
The aim of this thesis is measure the specimens placed in field of MR tomograph, the measured data to evaluace the process and measurement errors. The theoretical part is focused on describing basic parameters of magnetic field, commissioning some older methods of measurement and design methods for the measurement of samples not issuing MR signal. There is performed modeling for the proposed Metod and the 1D, 2D and 3D environments using COMSOL Multiphysics. The practical part is the measurements samples in the tomograph the Institute of Scientific Instruments Academy of Science in Brno. The measured data are processed in Marevisi and Matlab programs. The MATLAB program is written for processing, analysis and data evaluation, after which it is possible to determine the value of the magnetic susceptibility of the selected samples. In conclusion of the work is the quantification accuracy of measurements.
APA, Harvard, Vancouver, ISO, and other styles
17

Garcia, Garcia Olga. "Tomografia de coherència òptica swept-source com a mètode de valoració de la coroide en les coroiditis estromals primàries." Doctoral thesis, Universitat de Barcelona, 2017. http://hdl.handle.net/10803/402940.

Full text
Abstract:
ANTECEDENTS DEL TEMA: La valoració de la coroides s’ha fet fins el 2005 amb l’angiografia amb verd d’indocianina (AVI), mètode invasiu que requereix l’ injecció d’un contrast per vena antecubital. A partir del 2010, amb la tomografia de coherència òptica d’alta penetració, s’ha aconseguit valorar-la amb un mètode no invasiu. Però, l’ interpretació d’aquest mètode és lleugerament subjectiva i laboriosa, ja que requereix mesurar el gruix de la coroides de forma manual. Per tant, no és aplicable a la clínica diària. A partir del 2013 comença la tecnologia swept source. HIPÒTESI: Amb la utilització d’una tomografia de coherència òptica tipus swept source (SS-OCT), l’aparell es capaç de valorar automàticament el gruix coroïdal; la qual cosa pot permetre tenir una mesura objectiva de l’esmentat gruix i poder valorar l’evolució de les coroïditis estromals primàries (CEP) de forma més fiable, ràpida i no invasiva. OBJECTIUS: 1- Valorar les alteracions qualitatives de la coroides en les CEP en la fase aguda i crònica. 2- Valorar les alteracions quantitatives (variacions del gruix coroïdal) en la fase aguda per a valorar la resposta al tractament segons l’evolució del gruix coroïdal. 3- Valorar les alteracions quantitatives (variacions del gruix coroïdal) en la fase crònica/ convalescent per valorar la repercussió de la cicatrització i les recidives. 4- Valorar la diferencia entre el gruix coroïdal subfoveal i el promig del gruix de l’àrea corresponent a la reixeta de l’EDTRS en les CEP. METODOLOGIA UTILITZADA: Estudi prospectiu, longitudinal i cas-control dels pacients diagnosticats al Servei d’Oftalmologia de l’Hospital Universitari de Bellvitge des de finals del 2013 fins a finals del 2016. Realització d’una SS-OCT (prototipus Atlantis DRI-1 OCT, Topcon Corporation) en el diagnòstic i seguiment de les CEP [Síndrome de Vogt-Koyanagi-Harada (VKH) i malaltia de birdshot o corioretinopatia en perdigonada (BD)]. RESULTATS : 1- En la corioretinopatia en perdigonada, la SS-OCT ens confirma l’existència d’inflamació retiniana i coroïdal, gracies a les alteracions qualitatives observades; però, degut al poc engruiximent de la coroides i a la manca d’observació directa dels granulomes (pel seu petit tamany), no substitueix la informació obtinguda amb l’AVI. Tanmateix, son exploracions complementaries, ja que la SS-OCT ens permet discernir si les lesions hipofluorescents de l’angiografia son veritables zones inflamades o be zones atròfiques, i per tant, curades. Hi ha hagut una correlació positiva en el 60 % de les visites entre els resultats obtinguts amb la SS-OCT i la resta de les exploracions utilitzades fins ara pel seguiment de la malaltia ( camp visual, AVI i electroretinograma). 2- En la síndrome de VKH aguda, la SS-OCT ha demostrat ser molt útil pel diagnòstic (alteracions qualitatives: despreniments serosos multifocals bilaterals, septes,...i alteracions qualitatives: engruiximent coroïdal), i per a valorar la resposta al tractament (engruiximent coroïdal basal que es va aprimant). En la forma recidivant ha permès detectar l’augment del gruix coroïdal en les recidives; i en les formes curades, fer el seguiment de la malaltia (aprimament progressiu de la coroide) i diagnosticar recidives. La SS-OCT ha diagnosticat recidives coroïdals asimptomàtiques (sense pèrdua d’agudesa visual) que haurien passat desapercebudes. Del total de les recidives: 62.5 % en aguts, 42 % en recidivants i 25 % en curats, van ser diagnosticades amb SS-OCT). 3- En tots els casos s’ha confirmat la inflamació coroïdal detectada amb la SS-OCT mitjançant la realització d’una AVI. CONCLUSIONS: 1- La medició automàtica del gruix coroïdal amb la SS-OCT és una exploració ràpida, incruenta i objectiva que ha permès fer un millor seguiment de les CEP. 2- En la BD ens dona informació complementària a les exploracions que disposàvem fins ara. 3- En la VKH en fase aguda ha permès valorar la resposta al tractament i les recidives. En la fase convalescent/crònica ha permès valorar les recidives i la tendència a l’aprimament coroïdal. 4- La SS-OCT ha diagnosticat recidives coroïdals asimptomàtiques. 5- La SS-OCT podria estalviar l’AVI quan el diagnòstic de recaiguda és evident.
Background: Since 2010, high-penetration optic-coherence tomography (OCT) has been used to measure choroidal thickness manually. However, the choroid can be now be be measured automatically with swept-source OCT (SS-OCT). Hypothesis: Using the automatic measurement feature of SS-OCT to qualitatively and quantitatively assess changes in primary stromal choroiditis (PSC) may provide a rapid and accurate approach to monitoring these patients. Methods: Prospective, longitudinal case-control study of PSC [Vogt-Koyanagi-Harada syndrome (VKH) and birdshot disease (BD)] in a tertiary university hospital with a 3-year follow-up period (from 2013 to 2016). SS-OCT was performed at each visit and choroidal thickness was measured automatically. The study sample consisted of the following: 12 BD patients and 35 VKH patients (9 acute and 26 convalescent/chronic) and 17 healthy controls. There were no statistically differences between the groups in terms of sex or age at baseline. Patients with more than 3 diopters of myopia or hypermetropia were excluded. Results: 1- BD: SS-OCT confirms retinal and choroidal inflammation. However, the small size of the choroidal granulomas, together with the small increase in choroidal thickness, suggest that SS-OCT is best used as a complement to other methods, including visual acuity assessment, indocyanine green angiography (ICGA), electroretinogram, and visual field testing (which was perfectly correlated with SS-OCT in nearly 60% of patients) . 2- VKH: SS-OCT was useful in the diagnosis of VKH, helping to detect both qualitative (multifocal bilateral serous retinal detachments, retinal pigmentary epithelial folds, and ondulations) and quantitative changes (choroidal thickening). In addition, SS-OCT was valuable for follow-up, enabling detection of post-treatment decreases in choroidal thickness and increases in patients with VKH relapse: 62% of acute VKH choroidal relapses (42% of these relapses in the convalescent/chronic group) were diagnosed with SS-OCT based on increased choroidal thickness without loss of visual acuity and no intraocular signs of inflammation. 3- All the choroidal relapses were confirmed with inflammatory signs evidenced on ICGA. Conclusions: SS-OCT is a non-invasive and rapid approach to assessing choroidal and retinal changes in patients with primary stromal choroiditis (VKH and BD), providing a simple method of monitoring the course of these diseases. SS-OCT complements conventional tests in BD and decreases the need for ICGA in VKH.
APA, Harvard, Vancouver, ISO, and other styles
18

Kubásek, Ondřej. "Měření doběhu gradientních magnetických polí v MR tomografu." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2010. http://www.nusl.cz/ntk/nusl-218551.

Full text
Abstract:
The objective of my thesis is to measure magnetic field gradient decay in an MR tomograph, process and evaluate the data measured and analyse the issue. The theoretical section focuses on the reasons for the gradient distortion which has a negative impact on NMR measuring techniques and it also describes options to eliminate the negative effects, focusing mainly on pre-emphasis filtration. It also lists methods of gradient magnetic field measuring. The practical section contains results of magnetic field decay measurements taken with the tomograph in the Institute of scientific instruments of the Academy of sciences in Brno using the method of instantaneous frequency with and without pre-emphasis compensation. The data are processed with MAREVISI and MATLAB programmes. MATLAB is used to develop a modern method of filtration to eliminate noise in useful signal leading to more accurate measurements of MR magnetic fields. This filtration uses a method of time-dependent variable thresholds and two-channel filter banks. MATLAB is also used to design a programme for approximation of the measured gradient magnetic field decay. The decay must be approximated in order to obtain time constants and the degree of exponential decay, which serve to set up the pre-emphasis compensation.
APA, Harvard, Vancouver, ISO, and other styles
19

Accettola, Alessandra. "Tomografia quantistica: applicabilità e limiti." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2020. http://amslaurea.unibo.it/19973/.

Full text
Abstract:
I presupposti alla base dell’analisi tomografica dei fenomeni quantistici furono presentati in primis da Fano nel 1957. Egli colse alcune esigenze fondanti per un approccio nuovo allo studio quantistico, ad esempio la necessità di effettuare molteplici misure su sistemi preparati identicamente per ricostruire lo stato di un sistema quantistico. La proposta che, però, diede inizio propriamente alla tomografia quantistica fu quella di Vogel e Risken. Quest’ultima consisteva nell’utilizzare gli stessi algoritmi dell’imaging per la ricostruzione di uno stato quantistico. In primo luogo verrà fatto un excursus sulla meccanica quantistica, si presenteranno gli stati coerenti e la rappresentazione di Bergmann-Fock. Dopodiché si procederà con l’affrontare l’associazione di Weyl. Tutte le strutture matematiche precedenti serviranno per il passaggio da tomografia classica a quantistica. Verranno quindi presentati il ragionamento e gli algoritmi alla base della ricostruzione della distribuzione di massa di un oggetto e quindi della tomografia classica. Dopodiché sarà posta attenzione sulla definizione della funzione di Wigner generalizzata, funzione corrispondente ad una quasi distribuzione, rilevabile sperimentalmente. Si presenterà, inoltre, la metodologia di rilevazione sperimentale. Infine, saranno presentati gli algoritmi di ricostruzione dello stato quantistico. L’ampliamento al dominio quantistico, al netto della necessità di strumenti matematici adeguati, avviene con le stesse modalità della tomografia classica. Per questo motivo e per la possibilità di definire osservabili sia classici che quantistici nello stesso spazio, si può dire che il vero raggiungimento della tomografia è nella comparazione efficace di stati classici e quantistici.
APA, Harvard, Vancouver, ISO, and other styles
20

Kratochvíla, Jiří. "Dynamická fokusace v ultrazvukové tomografii." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2010. http://www.nusl.cz/ntk/nusl-218658.

Full text
Abstract:
The aim of the master’s thesis, is to get acquainted with the dynamic focusing in conventional ultrasound systems, to modify this method for ultrasound computer tomography and to realize and interpret this modification on simulated and real data in a transparent graphic interface. The modification of the dynamic focusing was executed for the 3D ultrasound computer tomograph developed in Karlsruhe. Simulated data, that are necessary for focusing, were generated by existing program, which was adjusted. The new created program of the dynamic focusing was tested and evaluated with those simulated and real data.
APA, Harvard, Vancouver, ISO, and other styles
21

Šejnohová, Marie. "Rentgenová počítačová tomografie embrya myši." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2015. http://www.nusl.cz/ntk/nusl-221377.

Full text
Abstract:
The aim of this semestral thesis is to compare the possibilities of available micro-CT systems. Theoretic part of this thesis there deals with possibilities of staining soft tissues and embryos because of enhancement the contrast of micro-CT images. Here follows a description of sources X-ray and detectors of available micro-CT systems. In practice there was realized the staining of embryo in cooperation with Department of histology and embryology in Brno. Then followed a measuring on FSI in Brno, ČVUT in Prague and synchrotron Elettra in Italy. In semestral thesis are described of the thesis there are compared the micro-CT systems and results of measuring embryos by means of presented systems and results are compared.The best results were obtained on micro-CT in Brno, where X-ray tube and flat panel detector were used. This images were used for a segmentation of cartilage olfactory system by means of 3D region growing. From results they were created 3D models for comparison with a manually segmented model. A less accurate results were obtain with the semi-automatic segmentation but this method isn’t too time-consuming.
APA, Harvard, Vancouver, ISO, and other styles
22

Gallego, Baena Susanna. "Creació d’un programa informàtic per a la valoració de la tomografia computeritzada en pacients amb poliposis nasosinusal. Estudi epidemiològic i creació d’una nova classificació objectiva radiològica." Doctoral thesis, Universitat Autònoma de Barcelona, 2016. http://hdl.handle.net/10803/401184.

Full text
Abstract:
La poliposis nasosinusal és una malaltia inflamatòria crònica que afecta a la mu¬cosa nasal i als sins paranasals. La prevalença de la poliposis nasosinusal és del 2 al 5% de la población. El diagnòstic de la poliposis es realitza a través de la clínica i l’exploració oto-rinolaringològica ja sigui per rinoscopia anterior com per endoscopia nasal. La prova d’imatge útil per al diagnòstic és la tomografia computeritzada. En l’actualitat existeixen vèries classificacions i estadiatges en la poliposis nasosinusal, però no existeix cap classificació objectiva. El tractament es basa en la combinació de tractament mèdic i quirúrgic, de¬penent de l’evolució de la malaltia. Les hipótesis del nostre estudi 1. És possible l’objectivitar, en tomografía computeritzada, l’ocupació dels sins paranasals avaluat a través del nombre de píxels. Fins a l’actualitat to¬tes les classificacions radiològiques en poliposis nasal estan basades en ter¬mes subjectius 2. Existeix una correlació estadísticament significativa en l’ocupació dels sins paranasals en la tomografía computeritzada en relació al grau de la malaltia. 3. És possible avaluar la decissió del tractament quirúrgic en relació al grau d’ocupació segons: tomografía computeritzada — grau de poliposis nasosinusal (valorada a través escala de lildholdt) 4. El grau de la malaltia, valorat a través d’endoscopia nasal i tomografía, ens pot determinar la decissió terapéutica en poliposis nasosinusal. Els objectius del nostre estudi 1. Creació d’un programa informàtic per a la segmentació d’imatges tomo¬gràfiques en pacients amb poliposis nasal. 2. Estudiar els diferents graus d’àrees i volums en la tomografia axial compu¬teritzada. 3. Estudiar la correl.lació existent entre la clínica, la tomografia computerit¬zada, abans i després de la cirurgia. 4. Crear una nova classificació i/o estadiatge de la poliposis nasosinusal en base a la tomografia computeritzada. Establir una correl.lació entre la tomografía computeritzada, en pacients amb poliposis, pacients amb poliposis i asma i pacients amb poliposis, asma i intolerancia a l’aspirina. 5. Estudiar la resposta al tractament a la simptomatologia nasal i les àrees i/o volum de la poliposis nasosinusal en el la tomografia computeritzada. 6. Establir una correl.lació amb endoscòpia nasal en pacients amb poliposis, poliposis nasal i poliposis nasal i asma. 7. Avaluar si existiexen diferències en la tomografía en pacients amb tracta¬ment mèdic versus el tractament quirúrgic.
The nasal polyposis is an inflamatory chronic disease who affects to the nasal mucosa and the paranasal sinus. The prevalence is arround 2-5%. The diagnose is doing about the clinical and complementary tests. The gold standard is axial tomography. In our days, there are some classifications about polyposis and TC, but there aren’t any objective classification. The treatment is based in medicine and surgery. The Hypotesis in this study are: 1.- It is possible to do and objective classification in TC, based in number of pixels 2.- There are a statistically significant correlation between the grade of disease and TC 3.- It is possible to decide the treatment based on grade occupation on TC and grade of nasal polyposis based on Lindholt classification. 4.- The grade of polyposis is a important factor to decide the correct treatment The objective in this study are: 1.- Creation a computer program for segmentation images on axial tomography in patients with nasal polyposis 2.- Study the different area and volume on axial tomography 3.- Study the correlation between the symptoms on axial tomography pre and post surgery 4.- Create a new classification of nasal polyposis in relation to axial tomography and to study the correlation between patients with nasal polyposis, nasal polyposis and asthma and nasal polyposis, asthma and intolerance to acidacetilsalycilic (AAS) 5.- Study the answer of treatment based on area and volume in axial tomography 6.- Study the correlation between nasal endoscopy in patients with polyposis, nasal polyposis and astma and nasal polyposis, asthma and intolerance to AAS 7.- Study if there are statistically significant differences in axial tomography between surgery and medical treatment.
APA, Harvard, Vancouver, ISO, and other styles
23

Saddy, Mario Sergio. "\"Estudo comparativo entre a tomografia computadorizada e a tomografia volumétrica na confecção de modelos de prototipagem\"." Universidade de São Paulo, 2006. http://www.teses.usp.br/teses/disponiveis/23/23139/tde-22032007-120737/.

Full text
Abstract:
O objetivo neste estudo foi comparar modelos de prototipagem, originados a partir de dados obtidos em exames de tomografia volumétrica (TV) e tomografia computadorizada (TC), a fim de verificar a precisão de reprodutibilidade destas tecnologias. Uma mandíbula seca foi submetida aos exames de TV (NewTom 9000? QR, Itália) e TC (Select SP-Elscint, Israel). Os dados obtidos nos exames foram manipulados em dois sistemas de tratamento de imagem, o 3D- Analyze (Mayo Clinic, E.U.A.) e o InVesalius (CenPRA, Brasil) e confeccionados protótipos, em duas diferentes tecnologias (SLS - sinterização seletiva a laser e 3DP - impressão tridimensional). A mandíbula seca (padrão ouro) e os oito conjuntos de protótipos gerados, sendo I-TC-Analyze?3DP; II-TC-Invesalius?3DP; III-TC-Analyze?SLS; IVTC- Invesalius-SLS; V-TV-Analyze?3DP; VI-TV-Invesalius?3DP; VIII-TV-Analyze? SLS; VIII-TV-Invesalius-SLS, foram submetidos a processos de engenharia reversa com a finalidade de digitalizar as superfícies dos objetos para uma comparação de cada modelo de prototipagem produzido com o padrão ouro, com precisão de 0,001mm. Os desvios de até 1mm e até 2mm foram calculados, comparados e analisados estatisticamente os erros percentuais. Os modelos de prototipagem rápida originados por meio da obtenção de dados de exames de tomografia computadorizada são mais precisos que os modelos de prototipagem originados por meio de dados de exames de tomografia volumétrica.
The purpose of this study is to compare rapid prototyping models created from cone beam computerized tomography (CBCT) and multislice computerized tomography (CT) data, in order to verify the accuracy of these technologies. A dry skull mandible was submitted in a CBCT (NewTom ? QR, Italy) and CT (Select SP-Elscint, Israel) exams. The tomographies data were processed by two different Medical Image processing systems, 3D-Analyze (Mayo Clinic, U.S.A.) and InVesalius (CenPRA, Brazil). Rapid prototypes models were built in two different rapid prototyping technologies, 3D Printer (3DP) and Selective Laser Sintering (SLS). The dry skull mandible (gold standard) and the eight prototypes, as follows; I-CT-Analyze?3DP; IICT- Invesalius?3DP; III-CT-Analyze?SLS; IV-CT-Invesalius-SLS; V-CBCT-Analyze? 3DP; VI-CBCT-Invesalius?3DP; VIII-CBCT-Analyze?SLS; VIII-CBCT-Invesalius-SLS, were submitted to a reverse engineering process aimed to digitalize the surfaces of the objects to compare each rapid prototype model with the gold standard with a precision of 0.001mm. Percentage deviations errors until 1.0mm and 2.0mm were calculated, compared and statistically analyzed. The prototyped models obtained with multislice computerized tomography data shows more accuracy than those obtained with data from cone beam computerized tomography.
APA, Harvard, Vancouver, ISO, and other styles
24

Silva, Isabela Maria de Carvalho Crusoé. "Avaliação comparativa dos coeficientes de Hounsfield entre a tomografia computadorizada de feixe cônico e tomografia multislice." [s.n.], 2011. http://repositorio.unicamp.br/jspui/handle/REPOSIP/290135.

Full text
Abstract:
Orientador: Solange Maria de Almeida
Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
Made available in DSpace on 2018-09-11T21:16:55Z (GMT). No. of bitstreams: 1 Silva_IsabelaMariadeCarvalhoCrusoe_M.pdf: 2322395 bytes, checksum: 2378f18e1c22e49e20d1b9f0670b3d52 (MD5) Previous issue date: 2011
Resumo: O objetivo no presente estudo foi comparar os coeficientes das unidades de Hounsfield (HU) em imagens adquiridas por tomografia de Feixe Cônico e tomografia multislice. Para tanto, foram utilizadas imagens de vinte mandíbulas maceradas adquiridas em dois tomógrafos: tomógrafo multislice de 40 canais (Somatom Sensation 40 - Siemens) com protocolo de cortes axiais de 0,7 mm de espessura e intervalo entre os cortes de 0,5 mm; e tomógrafo de feixe cônico i-CAT (Imaging Sciences International), com cortes axiais de 0,2 mm de espessura, tempo de aquisição de 40 segundos e Field of View (FOV) de 8 cm. As análises das imagens foram feitas pelos softwares Syngo CT (tomógrafo multislice). Os valores obtidos por este último foram considerados como Padrão Ouro. Para as mensurações foram utilizadas as coordenadas X e Y, bem como a ferramenta de HU de ambos os softwares. Ficando assim, viável a comparação dos resultados após as Análises Estatísticas Descritivas e do Teste t pareado. Os dados obtidos indicaram um valor médio das regiões de interesse de 313,13 HU para a tomografia multislice e de 418.06 HU para a tomografia de feixe cônico, com valor de P < 0,001. Portanto, os valores de HU, obtidos pelo software da tomografia de feixe cônico, apresentaram-se superestimados em relação aos encontrados no Tomógrafo multislice. Na ausência de correspondência entre os dados amostrados, a tomografia de feixe cônico não oferece segurança e credibilidade ao cirurgião-dentista na avaliação da densidade óssea no planejamento para implantes e em cirurgias do complexo maxilofacial
Abstract: The aim of this study was to compare the attenuation coefficients (Hounsfield Unit) in both cone-beam computed tomography (CT) and multislice CT images. The 40-channel CT scanner (SOMATOM Sensation 40 - Siemens) was used to obtain images (n=20) of macerated mandibles considering the following protocol: axial slices of 0.7 mm in thickness and an interval of 0.5 mm between cuts. This same sample was submitted to i-CAT cone-beam CT scanner (Imaging Sciences International): axial slices of 0.2 mm in thickness and a field of view of 8 cm. Images were analyzed by means of computer software - XoranCat (cone-beam CT scan) and the Syngo CT (multislice CT scan) - the latter of which was considered Gold Standard. Coordinates X and Y and the HU tool were used for the measurements. Data were submitted to the descriptive statistical analysis and the paired sample t-test. A mean value of 313.13 HU was obtained for Multislice CT and 418.06 HU for the cone-beam CT (p<0.001). The attenuation coefficient values obtained for the cone-beam CT were overestimated when compared to those for the multislice CT. Since no correspondence was found among the data sampled, cone-beam CT offers no credibility for the dentist to evaluate bone during planning of implant and/or maxillofacial complex surgery
Mestrado
Radiologia Odontologica
Mestre em Radiologia Odontológica
APA, Harvard, Vancouver, ISO, and other styles
25

La, Ciacera Giorgio. "Tomografia computerizzata a fascio conico (CBCT)." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2016. http://amslaurea.unibo.it/12315/.

Full text
Abstract:
Questo elaborato tratta le apparecchiature per la tomografia computerizzata a fascio conico (CBCT). Inizialmente sono descritte le caratteristiche dei raggi X ed il loro utilizzo in campo clinico, analizzando le varie tipologie di radiografia. Successivamente, si introduce il tomografo computerizzato, del quale si descrive la struttura e i principi di funzionamento, fino ad arrivare alla trattazione dei sistemi CBCT. Di questi viene studiato il funzionamento, il meccanismo di formazione delle immagini, gli ambiti di applicazione e i rispettivi vantaggi e limiti. Infine si analizza la dose di radiazione X emessa dall'apparecchiatura, studiando se il paziente corra rischi sottoponendosi a questi esami radiologici.
APA, Harvard, Vancouver, ISO, and other styles
26

Valente, Marcelo. "Torus Palatinus: estudo por Tomografia Computadorizada\"." Universidade de São Paulo, 1999. http://www.teses.usp.br/teses/disponiveis/5/5151/tde-18092014-113201/.

Full text
Abstract:
Estudou-se prospectivamente o comportamento das calcificações, da atrofia, das alterações da substância branca e alterações vasculares nas imagens de tomografia computadorizada de crânio de 162 crianças e adolescentes infectados pelo vírus da imunodeficiência humana (HIV) por transmissão vertical e que estavam ou estiveram em acompanhamento clínico no Ambulatório de Infectologia Pediátrica do Instituto da Criança do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, entre 1992 e 2002. Analisaram-se as possíveis correlações entre estas alterações e seu aspecto evolutivo. Para tal finalidade, foram avaliadas 606 tomografias computadorizadas de crânio (média de 3,74 exames por paciente), as quais constituíram o grupo de estudo. Após a caracterização quanto à presença ou não das alterações supracitadas, e suas possíveis inter-relações, realizou-se a análise estatística dos resultados obtidos através do teste exato de Fisher com nível de significância de 5%. Posteriormente, os mesmo aspectos foram avaliados em função do seu comportamento evolutivo em um subgrupo de 61 pacientes (média, 4,18 exames por paciente, totalizando 321 exames tomográficos). Estes pacientes tinham, pelo menos, quatro estudos tomográficos seriados (com intervalo mínimo de noventa dias entre os exames subseqüentes e pelo menos dois anos de intervalo total entre o primeiro e o último exame). As alterações tomográficas foram abordadas individual e qualitativamente segundo o critério de presença e intensidade. Inicialmente, o conjunto dos resultados foi tratado de forma individual (para cada paciente) e, depois, em relação à totalidade do grupo em questão. As calcificações foram encontradas em 46,30% dos pacientes; a atrofia, em 37,65%; as alterações da substância branca, em 25,93%; as anomalias vasculares, em 25,19%. Constatou-se uma correlação significativa entre as alterações de substância branca e a atrofia, bem como entre as calcificações e as alterações vasculares. A análise evolutiva destas características demonstrou haver um acréscimo significativo das alterações entre o momento inicial e o quarto momento no conjunto das alterações, sobretudo para as calcificações e para as alterações vasculares. Concluiu-se que as calcificações e a atrofia foram as alterações mais freqüentes nesta série de crianças e adolescentes com HIV adquirido por transmissão vertical. A atrofia e as alterações da substância branca apresentaram uma inter-relação importante na amostra descritiva, assim como as alterações vasculares e as calcificações mostraram uma associação evolutiva significativa em relação à sua progressão
We prospectively studied the behavior of calcifications, atrophy, white matter and vascular abnormalities on the images of computed tomography (CT) of 162 children and adolescents infected with the human immunodeficiency virus (HIV) acquired by vertical transmission, who are or were clinically followed in the Ambulatory of Pediatric Infectology of the Children Institute at the Clinics Hospital of University of São Paulo Medical School, from 1992 to 2002. We analyzed the possible correlation between these abnormalities, as well as, their evolutive aspects. For this purpose, we evaluated 606 CT scans (mean 3.74 exams per patient), which composed the group of study. After the characterization according to the presence or not of the anomalies mentioned above, and their possible inter-relations, we performed a statistical analysis of the obtained results with the Fisher test with a level of significance below 5%. Later, these aspects were evaluated regarding its evolutive behavior in a subgroup of 61 patients (mean, 4.18 exams per patient, summing 321 exams). These patients had, at least, four serial cranial CT (with minimum interval of ninety days between the subsequent exams and, at least, two years of total interval between the first and the fourth exam). The cranial CT abnormalities presented were assessed individually as absent or present. Initially, the set results were assessed individually (for each patient) and, later in relation to the totality of the group. Calcifications were found in 46.30% of all patients, atrophy in 37.65%, white matter abnormalities in 25.93% and vascular anomalies in 25.19%. We found a significant correlation between white matter abnormalities and atrophy, as well as, between calcifications and vascular anomalies. Evolutive analysis of these characteristics demonstrated a significant increase of the abnormalities between the first and the fourth moment, with emphasis to the calcifications and vascular anomalies. We concluded that, calcifications and atrophy were the most frequent abnormalities in this series of children and adolescents with HIV acquired by vertical transmission. Atrophy and white matter abnormalities presented a significant correlation in the descriptive sample, as well as, vascular anomalies and calcifications that also demonstrated a significant evolutive association regarding its progression
APA, Harvard, Vancouver, ISO, and other styles
27

Silva, Alcenísio José de Jesus. "Probabilidades negativas e tomografia de Qubits." Universidade Federal de São Carlos, 2007. https://repositorio.ufscar.br/handle/ufscar/4997.

Full text
Abstract:
Made available in DSpace on 2016-06-02T20:16:42Z (GMT). No. of bitstreams: 1 1653.pdf: 1076652 bytes, checksum: 1961cc3ed414f75dc01fe54141a52bb2 (MD5) Previous issue date: 2007-03-28
Financiadora de Estudos e Projetos
In this dissertation we approached the tomography of discrete systems, understood as the representation and the reconstruction of states. For the tomography we used distribution functions of symmetrical pseudo-probabilities. The coefficients of the distribution function of "probabilities" are "joint probabilities", that eventually can be negative, associated to incompatible observables. The "negative probabilities" contains not only information about the measurements of counts, but also on the quantum state of the systems. We present the argument of Scully, Walther and Schleich that uses double slit interference to give a meaning to the "negative probabilities" and we propose one alternative example using beam splitters and an single photon. Like this, moreover we define distribution functions based in generalized quantization axes for any directions, we present the physical interpretation of the resulting "negative probabilities". We showed the reason because all explanation usually done to justify "negative probabilities" seems to be contradictory and are not convincing. Is the interpretation of the "negative probabilities" that retain the heart, not only of the present work, but also, of the whole Quantum Mechanics, its only mystery, as Feynman says
Nesta dissertação abordamos a tomografia de sistemas discretos, entendida como a representação e a reconstrução de estados. Para a tomografia utilizamos funções distribuição de pseudo-probabilidades simétricas. Os coeficientes dessa função distribuição de "probabilidades" são "probabilidades conjuntas", que eventualmente podem ser negativas, associadas a observáveis incompatíveis. As "probabilidades negativas" contém não só informação sobre as medições de contagens, mas também sobre o estado quântico dos sistemas. Apresentamos o argumento de Scully, Walther e Schleich que utiliza interferência na dupla-fenda para dar um significado às "probabilidades negativas" e propomos um exemplo alternativo utilizando divisores de feixe e um único fóton. Assim, além de definir funções de distribuição baseadas em eixos de quantização generalizados para direções quaisquer, apresentamos a interpretação física das "probabilidades negativas" decorrentes. Mostramos porque toda explicação que possa ser feita para justificar "probabilidade negativa" parece ser contraditória e não é convincente. É na interpretação das pseudo-probabilidades onde está o coração não só do presente trabalho, mas também, de toda a Mecânica Quântica, o seu único mistério, como diz Feynman
APA, Harvard, Vancouver, ISO, and other styles
28

Fonseca, Filho Paulo Roberto da [UNESP]. "Tomografia por biosusceptometria de corrente alternada." Universidade Estadual Paulista (UNESP), 2014. http://hdl.handle.net/11449/123264.

Full text
Abstract:
Made available in DSpace on 2015-05-14T16:53:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-03Bitstream added on 2015-05-14T16:59:09Z : No. of bitstreams: 1 000822024_20160203.pdf: 74282 bytes, checksum: 81fcaba4dabd99298046b62189ca92be (MD5) Bitstreams deleted on 2016-02-03T15:35:12Z: 000822024_20160203.pdf,. Added 1 bitstream(s) on 2016-02-03T15:35:53Z : No. of bitstreams: 1 000822024.pdf: 798249 bytes, checksum: cf24aa6eedaa8b219d13e0e5cf032c2e (MD5)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos
The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research
APA, Harvard, Vancouver, ISO, and other styles
29

Fonseca, Filho Paulo Roberto da. "Tomografia por biosusceptometria de corrente alternada /." Botucatu, 2014. http://hdl.handle.net/11449/123264.

Full text
Abstract:
Orientador: José Ricardo de Arruda Miranda
Banca: Oswaldo Baffa Filho
Banca: Roberto Morato Fernandez
Banca: Fernando Gomes Romeiro
Banca: Valmir Fadel
Resumo: A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos
Abstract: The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research
Doutor
APA, Harvard, Vancouver, ISO, and other styles
30

Perlin, Lourenço Panosso. "Tomografia ultrassônica em concreto e madeira." reponame:Repositório Institucional da UFSC, 2015. https://repositorio.ufsc.br/xmlui/handle/123456789/158870.

Full text
Abstract:
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2015
Made available in DSpace on 2016-02-09T03:13:15Z (GMT). No. of bitstreams: 1 337478.pdf: 14260207 bytes, checksum: 2d17c4effaa380cc7a6b68e56a497c89 (MD5) Previous issue date: 2015
As edificações estão expostas a diversos tipos de ações degradativas, requerendo que inspeções periódicas sejam executadas. Para auxiliar estas inspeções, diferentes ensaios não destrutivos podem ser empregados, entre eles, o ultrassônico. Esta tese pesquisou a teoria tomográfica e demonstrou como a mesma pode ser utilizada para melhorar consideravelmente o resultado do ensaio ultrassônico, permitindo a visualização interna de seções transversais de elementos estruturais de concreto e madeira. Para isso, é descrito a implementação do programa computacional tomográfico TUCOM, responsável pela obtenção de tomogramas. A teoria empregada possibilita o cálculo de um caminho não retilíneo do pulso ultrassônico, contornando não homogeneidades e regiões de baixa velocidade. Além disso, através das equações de Christoffel e Hankinson, e pela discretização dos anéis de crescimento da madeira, foi possível incorporar a natureza anisotrópica das peças de madeira dentro do processamento tomográfico. Simulações numéricas e ensaios experimentais foram executados e utilizados no TUCOM, que emitiu tomogramas onde foi possível visualizar as diferentes formas de não homogeneidades conhecidas, demonstrando então as capacidades do método. Esta pesquisa confirmou que a tomografia ultrassônica é uma importante ferramenta na avaliação de possíveis patologias presentes em elementos estruturais de concreto e madeira.

Abstract : The buildings are exposed to several types of degradative actions, requiring the execution of periodic inspections. In order to help in these inspections, different non-destructive test methods can be used, with the ultrasonic pulse velocity being one of them. This thesis presents a research on the tomographic theory and its application to concrete and wood structural elements. It is demonstrated how tomography can be used to greatly improve the outcome of ultrasonic testing, allowing to visualize the internal cross-sections of concrete and wood structural elements. The implementation of tomographic software TUCOM, which supplies tomograms is described. Non-straight paths of the ultrasonic pulse were implemented, which avoid internal flaws and low density regions. Furthermore, using Christoffel and Hankinson equations, and the discretization of the wood growth rings, it was possible to incorporate the anisotropic nature of wood species in the tomographic processing. Numerical simulations and experimental tests were performed with TUCOM. In the generated tomograms it was possible to visualize the different shapes of known internal flaws, thus demonstrating the capabilities of the method. This research confirmed that the ultrasonic tomographic is an important tool in the evaluation of possible pathologies present in concrete and wood structural elements.
APA, Harvard, Vancouver, ISO, and other styles
31

MAGALHÃES, Cinthia Marques Sousa de. "Dosimetria em tomografia computadorizada utilizando fototransistor." Universidade Federal de Pernambuco, 2007. https://repositorio.ufpe.br/handle/123456789/9978.

Full text
Abstract:
Made available in DSpace on 2014-06-12T23:17:09Z (GMT). No. of bitstreams: 2 arquivo9131_1.pdf: 831093 bytes, checksum: 2cc080afeb09dcde8a47b4817e2ca483 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007
O aumento do uso da tomografia computadorizada (CT) na prática médica e a dose relativamente alta proporcionada ao paciente fazem da CT um forte contribuinte na dose populacional em radiologia médica. Portanto, existe a necessidade de avaliar e otimizar as doses de radiação em CT para os pacientes submetidos a essa técnica de radiodiagnóstico. A dosimetria atual é baseada na medida da integral do perfil de dose para um único corte utilizando uma câmara de ionização de 100 mm de extensão. Contudo, um sistema alternativo tem sido sugerido através da utilização de detectores menores. Nesse trabalho, o fototransistor OP520 foi proposto para avaliar a dose em raios-X de tomógrafo. Inicialmente, foi feita a caracterização do fototransistor em laboratório e no hospital. Em seguida, o detector foi utilizado no tomógrafo para avaliar o perfil de dose de um único corte no ar e num simulador de cabeça. Essas medidas foram feitas transladando o fototransistor através do feixe, utilizando múltiplas rotações da fonte e diferentes extensões de varredura. Os resultados da caracterização do fototransistor mostraram que o dispositivo apresenta resposta similar a do detector padrão para diferentes potenciais de tubo no experimento com o tomógrafo. As respostas em função da dose e da taxa de dose apresentaram comportamento linear, com coeficientes de determinação maiores que 0,95. A dependência angular foi expressiva nas irradiações em laboratório, mas no tomógrafo essa dependência foi menor que 3%. Os resultados das medidas do perfil de dose mostraram que o sensor pode ser utilizado para determinar os detalhes da distribuição de dose de um único corte em CT. Ao utilizar uma varredura de 100 mm de extensão, os perfis de dose obtidos com os fototransistores foram comparados com indicadores convencionais de dose no paciente em CT obtidos com a câmara de ionização: o índice de dose em tomografia computadorizada (CTDI) e o CTDI ponderado (CTDIw). A partir daí, obtiveram-se fatores de conversão para converter a medida em nC para dose em mGy e os indicadores puderam ser obtidos utilizando o fototransistor. Efetuando uma varredura de 150 mm de extensão, ao invés dos 100 mm usual, foi observado que existe dose além do comprimento da câmara de ionização em concordância com a opinião de alguns autores de que a dosimetria atual pode deixar de ser adequada
APA, Harvard, Vancouver, ISO, and other styles
32

Corrente, Diogo Emílio da Fonseca Ussemane Pires. "Tomografia computorizada intraoperatória na artrodese lombar." Master's thesis, Universidade de Aveiro, 2013. http://hdl.handle.net/10773/9916.

Full text
Abstract:
Mestrado em Materiais e Dispositivos Biomédicos
O presente relatório desenvolvido com base na prática clínica tem como objetivo demonstrar a importância da utilização da Tomografia Computorizada Intraoperatória (iTC) na realização de artrodese lombar, sendo este um procedimento que consiste na fusão de uma ou mais vértebras lombares de modo a aliviar a dor relacionada com certas patologias. A fusão entre as vértebras ocorre através da utilização de excertos ósseos ou outros materiais, como ligas metálicas, polímeros, compósitos ou cerâmicos. De modo a ajudar no processo de fusão são também utilizados dispositivos de fixação tais como parafusos pediculares, hastes e barras. A possibilidade de reconstruções MPR (Multiplanar Reformation) e VRT (Volume Rendering Technique), assim como a possibilidade de variar as janelas de visualização das imagens de iTC permitem uma melhor descriminação anatómica e, consequentemente, que a utilização da iTC, quando comparada com a do intensificador de imagem móvel, seja mais precisa na avaliação da colocação dos parafusos pediculares, evitando possíveis lesões causadas pela sua má colocação.
This report developed in clinical practice aims to demonstrate the importance of the intraoperative Computed Tomography (iCT) in the lumbar arthrodesis performance. It consists in the fusion of single or multiple lumbar vertebrae in order to relieve the pain related to some specific pathologies. The vertebral fusion is accomplished using bone grafts or other materials such as bone substitutes, metal alloys, polymers, composites or ceramics. In order to assist in the interbody fusion process, fixation devices such as pedicle screws, rods and plates are also used. The possibility of MPR (Multiplanar Reformation) and VRT (Volume Rendering Technique) reconstructions, as well as the ability of changing the windows levels of iCT images, allow a better anatomical discrimination and consequently, when compared with commonly used the mobile C-arm, the iCT appears more accurate in evaluating the placement of pedicle screws, avoiding possible injuries caused by their misplacement.
APA, Harvard, Vancouver, ISO, and other styles
33

Rocha, João Pedro Mendes. "Tomografia sísmica da Litosfera Continental Algarvia." Master's thesis, Universidade de Évora, 2010. http://hdl.handle.net/10174/21019.

Full text
Abstract:
A Tomografia Sísmica produz imagens detalhadas da litosfera, das variações de velocidade ou das suas velocidades absolutas (Tomografia Sísmica Local- TSL). Com a TSL é possível determinar a velocidade de propagação das ondas P e S. Em Portugal Continental, a região sul representa a zona de maior actividade sísmica e por isso mais susceptível de sofrer impactes significativos. Em Janeiro de 2006 o Centro de Geofísica de Évora/Universidade de Évora (CGE/UE), instalou uma rede sísmica na região Algarvia. Os dados entre Janeiro e Abril de 2006 foram processados e analisados, tendo-se procedido à sua localização, relocalização e inversão. A TSL realizada principalmente nas regiões compreendidas entre Monchique­ Portimão (M-P) e Loulé-Faro (L-F) permitirá um conhecimento detalhado da crosta e possibilitará o constrangimento dos limites das zonas sismogénicas e a determinação das áreas geradoras de sismos e zonas de falhas activas na região. – ABSTRACT: Seismic Tomography produces detailed images of the litosphere, of the variations in velocity or in terms of its absolute velocities (Local Earthquake Tomography- LET). With the LET is possible to determine the velocity propagation of P and S seismic waves. ln Continental Portugal, the region at south and respective coastline, represents the major seismic zone and so has more susceptibility to this hazard. ln January 2006, the Geophysical Centre of Évora/University of Évora (CGEIUE), installed a seismic network in the Algarve region. Data corresponding to the period between January and April 2006 were processed and analyzed, to proceed for location, relocation and inversion. The LET of Monchique-Portimão (M-P) and Loulé-Faro (L-F) will give knowledge of the crust and will constrain the limits of seismogenic zones and also determines the potential areas responsible for major earthquakes as active faults in the region.
APA, Harvard, Vancouver, ISO, and other styles
34

Basso, Caio Ferraz. "Padronização do volume pulmonar pela tomografia." Botucatu, 2019. http://hdl.handle.net/11449/183536.

Full text
Abstract:
Orientador: Sergio Marrone Ribeiro
Resumo: A medida correta e acurada do volume pulmonar é uma importante ferramenta de avaliação diagnóstica e terapêutica na prática clínica. Atualmente, com o avanço da capacidade de reconstrução tridimensional da Tomografia Computadorizada (TC) é possível mensurar o volume pulmonar total por este aparelho. O presenta trabalho busca apresentar uma nova técnica de mensuração do volume pulmonar e estabelecer uma padronização de valores normais do volume pulmonar na população adulta. O volume pulmonar total de 95 pacientes, assim como quatro medidas antropométricas obtidas na TC foram analisados. Em um intervalo de confiança de 95%, se estabeleceu os limites inferiores e superiores da relação entre o volume e cada uma das medidas, assim valores de importância estatística.
Abstract: Correct and accurate measurement of lung volume is an important diagnostic and therapeutic evaluation tool in clinical practice. Nowadays, with the advancement of the capacity of three-dimensional reconstruction of Computed Tomography (CT), it is possible to measure the total lung volume by this device. The present paper aims to present a new technique for measuring lung volume and establish a standardization of normal values of lung volume in the adult population. The total lung volume of 95 patients, as well as four anthropometric measurements obtained at CT were analyzed. In a 95% confidence interval, we established the lower and upper limits of the relationship between the volume and each of the measures, thus values of statistical importance.
Mestre
APA, Harvard, Vancouver, ISO, and other styles
35

Pop, Tomáš. "Měření rychlosti šíření ultrazvuku průzvučnou tomografií." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2008. http://www.nusl.cz/ntk/nusl-217179.

Full text
Abstract:
The study deals with the image reconstructions using the ultrasound propagation speed measuring and it extends the project of the ultrasound transmission tomography organised in cooperation with the research centre Forschungszentrum Karlsruhe (Germany). There were data processed which had been gained with the 3D ultrasound transmission tomography system (3D USCT). The ultrasound propagation speed was measured using the detection of ultrasound ray travelling time from a transmitter to a receiver. There were three new algorithms developed for the detection of an ultrasound impulse and the software generating suitable testing data. The developed algorithms were consequently tried with these data and, then, included into the existing software. All software was developed within the Matlab programming environment.
APA, Harvard, Vancouver, ISO, and other styles
36

Filipík, Adam. "KALIBRACE ULTRAZVUKOVÉHO PRŮZVUČNÉHO SYSTÉMU VÝPOČETNÍ TOMOGRAFIE." Doctoral thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2009. http://www.nusl.cz/ntk/nusl-233451.

Full text
Abstract:
Tato dizertace je zaměřena na medicínskou zobrazovací modalitu – ultrazvukovou počítačovou tomografii – a algoritmy zlepšující kvalitu zobrazení, zejména kalibraci USCT přístroje. USCT je novou modalitou kombinující ultrazvukový přenos signálů a principy tomografické rekonstrukce obrazů vyvíjených pro jiné tomografické systémy. V principu lze vytvořit kvantitativní 3D obrazové objemy s vysokým rozlišením a kontrastem. USCT je primárně určeno pro diagnózu rakoviny prsu. Autor spolupracoval na projektu Institutu Zpracování dat a Elektroniky, Forschungszentrum Karlsruhe, kde je USCT systém vyvíjen. Jeden ze zásadních problémů prototypu USCT v Karlsruhe byla absence kalibrace. Tisíce ultrazvukových měničů se liší v citlivosti, směrovosti a frekvenční odezvě. Tyto parametry jsou navíc proměnné v čase. Další a mnohem závažnější problém byl v pozičních odchylkách jednotlivých měničů. Všechny tyto aspekty mají vliv na konečnou kvalitu rekonstruovaných obrazů. Problém kalibrace si autor zvolil jako hlavní téma dizertace. Tato dizertace popisuje nové metody v oblastech rekonstrukce útlumových obrazů, kalibrace citlivosti měničů a zejména geometrická kalibrace pozic měničů. Tyto metody byly implementovány a otestovány na reálných datech pocházejících z prototypu USCT z Karlsruhe.
APA, Harvard, Vancouver, ISO, and other styles
37

Štohanzlová, Petra. "Perfuzní modelování v optické koherentní tomografii." Doctoral thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2018. http://www.nusl.cz/ntk/nusl-371796.

Full text
Abstract:
This thesis deals mainly with perfusion modeling in optical coherence tomography (OCT). The introductory part deals with basic theory of the OCT, including a description of its basic applications. Part of the work was the testing of selected contrasting materials suitable for the OCT and the design and implementation of phantoms, which were subsequently used in the main part of the thesis. In the practical part, attention is paid to the perfusion analysis in the OCT, first the application of the dilution theory in the OCT for flow estimation, then a study testing the basic theory of perfusion on OCT by means of tissue phantom. Another part of the thesis is devoted to the method of speckle variance analysis for flow visualization.
APA, Harvard, Vancouver, ISO, and other styles
38

Pizzi, María Nazarena. "Tomografía por emisión de positrones con 18F-fluordesoxiglucosa/Angio-Tomografía cardíaca (PET/CTA) en pacientes con sospecha de endocarditis infecciosa: Utilidad diagnóstica e impacto en las decisiones terapéuticas." Doctoral thesis, Universitat Autònoma de Barcelona, 2019. http://hdl.handle.net/10803/667481.

Full text
Abstract:
La endocarditis infecciosa (EI) es una patología grave que continúa teniendo mal pronóstico a pesar de los avances en el tratamiento médico y quirúrgico y cuyo diagnóstico es siempre un desafío clínico. De la misma manera, la infección de dispositivos intracardíacos es un problema creciente que también comporta una alta morbimortalidad y que posee importantes dificultades diagnósticas. Por este motivo el desarrollo de una nueva técnica de imagen que contribuya a mejorar la detección de estas patologías constituye un tema de relevancia en el momento actual. La presente tesis doctoral se compone de dos artículos que analizan diferentes aspectos de la utilidad de la tomografía por emisión de positrones con 18F-fluordesoxiglucosa/ Angiotomografía computarizada cardíaca (18F-FDG-PET/CTA (PET/CTA) para el diagnóstico de EI y la infección de dispositivos intracardíacos. El primer artículo demuestra que que el PET-CT/CTA es una técnica útil en el diagnóstico de los pacientes con sospecha de EI portadores de válvulas protésicas o dispositivos intracardíacos y que la combinación de sus hallazgos con los Criterios de Duke modificados mejora la sensibilidad diagnóstica del 52% al 90,7% permitiendo establecer un diagnóstico concluyente en el 95% de los casos en esta población de enfermos. Asimismo, demuestra que la combinación de la gran sensibilidad para detectar inflamación de la 18F-FDG-PET/CT con la alta resolución espacial del CTA cardíaco para definir el daño estructural es la mejor estrategia para el diagnóstico y la detección de complicaciones periprotésicas, con resultados superiores al PET/CT convencional (sensibilidad diagnóstica del 88,6% para la combinación de los Criterios de Duke y los estudios de PET/CT sin contraste y del 91% para la combinación de los primeros con el PET/CTA). El segundo artículo aborda la utilidad de esta técnia en un grupo particularmente complejo de pacientes adultos con cardiopatías congénitas y portadores de materiales protésicos, observándose también un incremento de la sensibilidad diagnóstica en estos últimos del 39,1% al 87%, con un diagnóstico concluyente en el 92% de los casos. Dicho incremento representa un impacto superior al demostrado en la población general. En forma adicional y en ambos grupos, el PET-CT/CTA permitió documentar eventos embólicos y metástasis sépticas en un 15% de los casos, identificó la puerta de entrada de la bacteriemia en casos concretos y ofreció un diagnóstico alternativo en el 54% de los casos de EI o infección de dispositivos intracardíacos rechazadas.
Infectious endocarditis (IE) is a serious pathology that continues to have a poor prognosis despite advances in medical and surgical treatment and its diagnosis poses always a clinical challenge. In the same way, the infection of intracardiac devices is a growing problem that also entails a high morbidity and mortality and that has important diagnostic difficulties. For this reason, the development of a new imaging technique that contributes to improve the detection of these pathologies is an issue of relevance at the present time. This doctoral thesis is composed of two articles that analyze different aspects of the usefulness of the positron emission tomography with 18F-fluorodeoxyglucose/cardiac computed tomography (18F-FDG-PET/CTA (PET CTA) for the diagnosis of IE and the infection of intracardiac devices. The first article shows that PET-CT/CTA is a useful technique in the diagnosis of patients with suspected prosthetic valve IE or intracardiac device infection and that the combination of its findings with the modified Duke Criteria improves the diagnostic sensitivity from 52% to 90.7%, making it possible to establish a conclusive diagnosis in 95% of the cases in this patient population. Besides, it demonstrates that the combination of the high sensitivity of the 18F-FDG-PET/CT to detect inflammation with the high spatial resolution of the cardiac CTA to define structural damage is the best strategy for the diagnosis and the detection of periprosthetic complications, with superior results to the conventional PET/CT technique (diagnostic sensitivity of 88.6% for the combination of the Duke Criteria and non-enhance PET/CT and 91% for the combination of the former with the PET/CTA). The second article addresses the usefulness of this technique in a particularly complex group of adult patients with congenital heart disease that have several prosthetic materials also observing an increase in the diagnostic sensitivity in this specific cohort, from 39.1% to 87%, with a conclusive diagnosis in 92% of the cases. This increase represents a greater impact than that observed in the general population. Additionally and in both groups, the PET-CT/CTA allowed the detection of embolic events and septic metastases in 15% of the cases, identified the source of the bacteremia in some specific cases and elucidated an alternative diagnosis in 54% of the rejected IE or device infection cases.
APA, Harvard, Vancouver, ISO, and other styles
39

Gras, Andreu Clàudia. "Inversion of multichannel seismic data by combination of travel-time and full-waveform tomography." Doctoral thesis, Universitat de Barcelona, 2019. http://hdl.handle.net/10803/668456.

Full text
Abstract:
This thesis presents the implementation and application of a procedure combining different geophysical techniques to extract high-resolution information that helps characterizing the structure and properties (p-wave velocity, Vp) of the subsurface by using marine multichannel seismic (MCS) data alone. The challenge is overcoming the inherent non-linearity and non-uniqueness of inverse methods, in general, and of full-waveform inversion (FWI), in particular, which are especially critical for short-offset, band-limited seismic data. I have designed and applied a modelling sequence consisting of: (1) data re-datuming or downward continuation (DC) by back-propagation of the recorded seismograms to the seafloor; (2) travel-time tomography (TTT) using especially the first arrivals of the re-datumed shot gathers, and (3) FWI of the original shot gathers using the model obtained by TTT as initial reference. This workflow is first tested with synthetic data, and then applied to field data acquired in the Alboran Sea (SE Iberia). Due to the short source-receiver offset and the depth of the water column, refractions are hardly identified as first arrivals. To solve this problem, I changed the reference datum of the data set from the sea surface to the seafloor, by implementing a DC code that uses a solver of the acoustic wave equation developed at Barcelona-CSI [Dagnino et al., 2016]. By modifying the MCS records to simulate a seafloor-type acquisition it is possible to recover refracted phases, crucial in Vp modelling, as first arrivals. Then, I performed TTT using the travel times of the DC first arrivals to obtain a coarse, but kinematically correct, Vp model. This TTT Vp model has the correct low-wavenumber information because the waveforms simulated with the inverted model and the recorded ones are not cycle-skipped. To better constrain the result, particularly in the deep parts of the model, I have incorporated the seismic phases corresponding to a major reflecting interface (top of the basement, TOB) and performed a joint refraction and reflection TTT combining the original and the DC field data. Finally, finer structural details are progressively introduced in the initial model by applying iterative, multi-scale FWI to the original MCS data. The results confirm that the combination of data re-datuming and TTT provides reference models that are accurate enough to apply FWI to relatively short offset streamer data in deep-water settings as the ones used, even if records lack low frequencies (< 4 Hz). I also show that, when the initial model is not kinematically correct, the FWI falls into a local minimum. The application of the workflow to the Alboran field data reveals a number of geological structures in the FWI Vp model that cannot be appreciated in the TTT Vp model, nor easily interpreted based on MCS images alone. A sharp strong velocity contrast defines the geometry of an irregular TOB that includes high velocity volcano-like structures. The model clearly images steeply dipping Vp changes at the flanks of the basin that may correspond to faults. Moreover, it displays a 200–300 m thick high-velocity layer that could probably correspond to evaporites deposited during the Messinian crisis in the Mediterranean. The result is validated by comparing the two-way time-transformed Vp model and the time-migrated MCS image, showing that velocity changes coincide with major reflectivity contrasts. Overall, this study shows that by using an appropriate workflow, in our case including DC of MCS data to the seafloor, joint refraction and reflection TTT, and FWI, accurate, geologically meaningful Vp models can be obtained even for non-optimal data sets. In particular, our results provide information that improves the geological characterization and interpretation of the subsurface of the Alboran Basin. The main results have recently been published in Solid Earth [https://doi.org/10.5194/se-2019-46].
Aquesta tesi presenta el desenvolupament, implementació i aplicació d'un procediment que combina diferents tècniques d'inversió tomogràfica per extreure informació d'alta resolució que permeti caracteritzar l'estructura i propietats (velocitat d'ona p, Vp) del subsòl marí, utilitzant exclusivament dades de sísmica de reflexió multicanal (MCS). El repte principal és el de superar els problemes inherents de no-linealitat i no-unicitat dels mètodes d'inversió, en general, i de la inversió de forma d’ona completa (FWI), en particular, especialment crítics en registres sísmics que manquen de baixes freqüències (<4 Hz) i han estat adquirits amb un abast experimental relativament curt (~6 km). Per afrontar el problema, l’estudi proposa i segueix un flux de treball que primer es posa a prova amb dades sintètiques, i després s'aplica a dades de camp adquirides al mar d’Alboran. Primerament es va desenvolupar un codi que modifica les dades sísmiques retro-propagant-les a la superfície del fons marí, simulant així una adquisició virtual en aquesta superfície. Els registres resultants permeten identificar les refraccions com a primeres arribades, que aporten informació robusta i essencial per modelar la Vp. Posteriorment, amb els temps d'aquestes arribades es va dur a terme la tomografia de temps de trajecte (TTT). En l'aplicació amb dades de camp, es va afegir la reflexió del sostre del basament (TOB) per acotar millor el resultat. Els models obtinguts mostren la variació de Vp correcta del subsòl, ja que els sismogrames simulats amb aquests models i els que es pretenen reproduir no mostren desfasaments importants. Aquest fet possibilita la correcta aplicació de tècniques més complexes com la FWI utilitzant el model de TTT com a inicial. La FWI proporciona un model de Vp d’alta resolució del medi utilitzant tot el camp d'ones de les dades originals. Aquesta tesi és la primera aplicació pràctica de FWI amb dades de camp a nivell nacional, i s’han utilitzat essencialment codis desenvolupats al BCSI. Els resultats revelen diverses formes geològiques d'interès, la geometria irregular del TOB, causada per possibles estructures volcàniques, i falles; a més d'una capa d'alta Vp que pot correspondre a evaporites dipositades durant el Messinià. Els resultats principals s’han publicat recentment a Solid Earth [https://doi.org/10.5194/se-2019-46].
APA, Harvard, Vancouver, ISO, and other styles
40

Rosell, Ferrer Francesc Xavier. "Tomografía de impedancia eléctrica para aplicaciones médicas." Doctoral thesis, Universitat Politècnica de Catalunya, 1989. http://hdl.handle.net/10803/6371.

Full text
Abstract:
En esta tesis se analizan las bases de la Tomografía de Impedancia Eléctrica (TIE) desde los aspectos de campos electromagnéticos, los electrodos y las propiedades eléctricas de los tejidos en seres vivos. Se analizan los distintos tipos de sistemas electrónicos para poder obtener los datos de impedancia en sistemas multielectrodo para TIE y los métodos para obtención de imágenes. A partir de estos estudios se diseña e construye un sistema de TIE. Este sistema se verifica en maquetas resistivas y en medidas sobre humanos. Las contribuciones más relevantes son en el diseño del equipo (con soluciones inéditas como la realimentación activa y los algoritmos para calibración y detección de forma), el análisis de la sensibilidad para distintas estrategias de inyección y el estudio sobre impedancia de electrodos en diversas posiciones del cuerpo.
In this thesis we analyze the basic concepts of the Electrical Impedance Tomography (EIT), from electromagnetic field theory, electrodes and the electrical properties of biological tissues. We analyze different types of electronic systems to be able to obtain the information of impedance in multielectrode systems for TIE and the methods for obtaining images. From these studies, a TIE system is designed and constructed. This system is tested in resistive models and in measures on human beings. The most relevant contributions are in the design of the equipment (with innovative solutions like the active feedback and the algorithms for calibration and detection of the objects's shape section), the analysis of the sensitivity for different strategies of current injection and the study of electrode impedance in different body locations
APA, Harvard, Vancouver, ISO, and other styles
41

Rosell, Ferrer Javier. "Tomografía de impedancia eléctrica para aplicaciones médicas." Doctoral thesis, Universitat Politècnica de Catalunya, 1989. http://hdl.handle.net/10803/6371.

Full text
Abstract:
En esta tesis se analizan las bases de la Tomografía de Impedancia Eléctrica (TIE) desde los aspectos de campos electromagnéticos, los electrodos y las propiedades eléctricas de los tejidos en seres vivos. Se analizan los distintos tipos de sistemas electrónicos para poder obtener los datos de impedancia en sistemas multielectrodo para TIE y los métodos para obtención de imágenes. A partir de estos estudios se diseña e construye un sistema de TIE. Este sistema se verifica en maquetas resistivas y en medidas sobre humanos. Las contribuciones más relevantes son en el diseño del equipo (con soluciones inéditas como la realimentación activa y los algoritmos para calibración y detección de forma), el análisis de la sensibilidad para distintas estrategias de inyección y el estudio sobre impedancia de electrodos en diversas posiciones del cuerpo.
In this thesis we analyze the basic concepts of the Electrical Impedance Tomography (EIT), from electromagnetic field theory, electrodes and the electrical properties of biological tissues. We analyze different types of electronic systems to be able to obtain the information of impedance in multielectrode systems for TIE and the methods for obtaining images. From these studies, a TIE system is designed and constructed. This system is tested in resistive models and in measures on human beings. The most relevant contributions are in the design of the equipment (with innovative solutions like the active feedback and the algorithms for calibration and detection of the objects's shape section), the analysis of the sensitivity for different strategies of current injection and the study of electrode impedance in different body locations
APA, Harvard, Vancouver, ISO, and other styles
42

Sassi, Andrea. "PET (Positron Emission Tomography) e tomografia computerizzata." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2013. http://amslaurea.unibo.it/4961/.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Nanni, Giacomo. "Tomografia a coerenza ottica: principi ed applicazioni." Bachelor's thesis, Alma Mater Studiorum - Università di Bologna, 2016. http://amslaurea.unibo.it/11568/.

Full text
Abstract:
La tomografia a coerenza ottica (Optical Coherence Tomography, OCT) rappresenta fondamentalmente una nuova modalità di diagnostica per immagini non invasiva e ad alta risoluzione. L’OCT fornisce immagini, sotto forma di sezioni trasversali o tomografiche, delle microstrutture dei tessuti biologici tramite la misura del ritardo dell’eco e dell’intensità della luce retrodiffusa o riflessa dal campione in analisi. L’OCT è una potente tecnica poiché fornisce in tempo reale immagini in situ delle strutture tissutali normali o patologiche, con una risoluzione da 1 a 15 micron, che è da uno a due ordini di grandezza maggiore rispetto alle tecniche per immagini convenzionali come ultrasuoni, risonanza magnetica o tomografia computerizzata. Tutto questo senza la necessità di ottenere e analizzare un campione tramite biopsia e studio istopatologico. Sin dall’inizio della sua utilizzazione nel 1991, l’OCT è stata impiegata in un vasto spettro di applicazioni cliniche, principalmente l'oftalmologia. In strutture non trasparenti, diverse da quelle oculari, la profondità massima esplorabile è limitata a 2-3 mm a causa dei fenomeni di attenuazione secondari e alla dispersione della luce. Inoltre, i numerosi sviluppi fatti dalla tecnologia OCT hanno portato ad alte velocità di acquisizione e, grazie all’utilizzo di sorgenti laser di ultima generazione, risoluzioni assiali dell’ordine di 1 micrometro. Dunque, la tomografia a coerenza ottica può essere sfruttata: - Quando la biopsia escissionale è pericolosa o impossibile. - Quando si rischiano errori di campionamento, come guida alla biopsia in modo da ridurre errori nel prelievo del campione. - Come guida alla procedura d’intervento, in associazione alle procedure di cateterismo, endoscopia e laparoscopia.
APA, Harvard, Vancouver, ISO, and other styles
44

Helou, Neto Elias Salomão. "Algoritmos incrementais com aplicações em tomografia computadorizada." [s.n.], 2009. http://repositorio.unicamp.br/jspui/handle/REPOSIP/307603.

Full text
Abstract:
Orientador: Alvaro Rodolfo De Pierro
Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Cientifica
Made available in DSpace on 2018-08-13T11:27:52Z (GMT). No. of bitstreams: 1 HelouNeto_EliasSalomao_D.pdf: 7993687 bytes, checksum: 12333395c593dd0cbddf79352f61c458 (MD5) Previous issue date: 2009
Resumo: O problema de viabilidade convexa é um campo fértil de pesquisa que deu origem a uma grande quantidade de algoritmos iterativos, tais como pocs, art, Cimmino e uma miríade de variantes. O motivo para tal interesse é o amplo leque de aplicabilidade que algoritmos gerais para a solução de problemas desse tipo podem alcançar. Dentre tais aplicações encontra-se a reconstrução de imagens em tomografia, caso que geralmente apresenta uma estrutura especial de esparsidade e tamanhos gigantescos. Também bastante estudados por seu interesse prático e teórico são problemas envolvendo a minimização irrestrita de funções convexas. Aqui, novamente, a variada gama de aplicações torna impossível mencionar uma lista minimamente abrangente. Dentre essas a tomografia é, outra vez, um exemplo de grande destaque. No presente trabalho desenvolvemos uma ponte que permite o uso de uma variedade de métodos para viabilidade em conjunto com algoritmos de otimização para obter a solução de problemas de otimização convexa com restrições. Uma teoria geral de convergência é apresentada e os resultados teóricos são especializados em métodos apropriados para problemas de grande porte. Tais métodos são testados em experimentos numéricos envolvendo reconstrução de imagens tomográficas. Esses testes utilizam-se da teoria de amostragem compressiva desenvolvida recentemente, através da qual conseguimos obter resultados sem par na reconstrução de imagens tomográficas a partir de uma amostragem angular altamente esparsa da transformada de Radon. Imagens obtidas a partir de dados simulados são recuperadas perfeitamente com menos de 1/20 das amostras classicamente necessárias. Testes com dados reais mostram que o tempo de uma leitura spect pode ser reduzido a até 1/3 do tempo normalmente utilizado, sem grande prejuízo para as reconstruções.
Abstract: The convex feasibility problem is a research field which has originated a large variety of iterative algorithms, such as pocs, art, Cimmino and a myriad of variants. The reason for such interest is the wide array of applicability that general algorithms for this kind of problem may reach. Among such applications there is tomographic image reconstruction, instance that generally presents a special sparsity structure and huge sizes. Also widely studied because its practical and theoretical interests are problems involving unconstrained minimization of convex functions. Here, again, the huge array of applications makes it impossible to mention even a minimal list. Among these, once more, tomography is a major example. In the present work we have developed a bridge that allows the use of a variety of methods for feasibility in conjunction with optimization algorithms in order to obtain the solution for convex optimization problems with restrictions. A general convergence theory is presented and the theoretical results are specialized into methods useful for large scale problems. These methods are tested in experiments involving tomographic image reconstruction. Such tests make use of the recently developed compressive sensing theory, through which we have been able to obtain unmatched results in tomographic image reconstruction from highly sparse angular sampling from the Radon transform. Images obtained from simulated data are perfectly reconstructed using less than 1/20 from the classically needed. Tests with real data show that the time of a spect scan can be reduced to 1/3 of the usual, without too much image deterioration.
Doutorado
Matematica Aplicada
Doutor em Matemática Aplicada
APA, Harvard, Vancouver, ISO, and other styles
45

Gonçalves, Douglas Soares 1982. "Métodos matemáticos em tomografia de estados quânticos." [s.n.], 2013. http://repositorio.unicamp.br/jspui/handle/REPOSIP/305944.

Full text
Abstract:
Orientadores: Marcia Aparecida Gomes Ruggiero, Carlile Campos Lavor
Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Matemática, Estatística e Computação Científica
Made available in DSpace on 2018-08-21T21:36:13Z (GMT). No. of bitstreams: 1 Goncalves_DouglasSoares_D.pdf: 2439739 bytes, checksum: 5c9361d700cb32cae7880de49fa5e892 (MD5) Previous issue date: 2013
Resumo: A preparação, manipulação e caracterização de sistemas quânticos são tarefas essenciais para a computação quântica. Em Tomografia de Estados Quânticos, o objetivo é encontrar uma estimativa para a matriz de densidade, associada a um ensemble de estados quânticos identicamente preparados, baseando-se no resultado de medições. Este é um importante procedimento em computação e informação quântica, sendo aplicado, por exemplo, para verificar a fidelidade de um estado preparado ou em tomografia de processos quânticos. Nesta tese, estudamos métodos matemáticos aplicados aos problemas que surgem na reconstrução de estados quânticos. Na estimação por Máxima Verossimilhança, apresentamos dois métodos para a resolução dos problemas de otimização dessa abordagem. O primeiro se baseia em uma reparametrização da matriz de densidade e, neste caso, provamos a equivalência das soluções locais do problema de otimização irrestrita associado. No segundo, relacionado à verossimilhança multinomial, demonstramos a convergência global do método sob hipóteses mais fracas que as da literatura. Apresentamos também duas formulações para o caso de tomografia com um conjunto incompleto de medidas: Máxima Entropia e Tomografia Quântica Variacional. Propusemos uma nova formulação para a segunda, de modo a apresentar propriedades mais parecidas as da Máxima Entropia, mantendo a estrutura de um problema de programação semidefinida linear. Para outros problemas de otimização sobre o espaço de matrizes de densidade além do problema da Tomografia de Estados Quânticos, apresentamos um método de Gradiente Projetado que se mostrou efetivo em testes numéricos preliminares. Por fim, discutimos sobre a implementação de inferência Bayesiana, através de métodos Monte Carlo via cadeias de Markov, no problema de estimação da matriz de densidade
Abstract: Preparation, manipulation and characterization of quantum states are essential tasks for quantum computation. In Quantum State Tomography, the aim is to find an estimate for the density matrix associated to an ensemble of identically prepared quantum systems, based on the measurement outcomes. This is an important procedure in quantum information and computation applied for instance, to verify the fidelity of a prepared state or in quantum process tomography. In this thesis we study mathematical methods applied to problems that raise from the reconstruction of quantum states. In the Maximum Likelihood Estimation we present two methods to solve the optimization problems of this approach. The first one is based on a reparameterization of the density matrix and, in this case, we prove the equivalence of local solutions of the related unconstrained optimization problem. In the second one, related to multinomial likelihoods, we prove the global convergence of the method under weaker assumptions than those of literature. We also discuss two formulations to the case of quantum state tomography with incomplete measurements: Maximum Entropy and Variational Quantum Tomography. We propose a new formulation for the second one in order to have a similar behavior to the Maximum Entropy approach, keeping the linear semidefinite positive programming structure. Furthermore, in order to solve other optimization problems over the density matrices space besides the Quantum State Tomography, we present a Projected Gradient method which shows a good performance in preliminary numerical tests. We also briefly talk about the implementation of a Bayesian inference scheme, through Monte Carlo Markov chains methods, to the density matrix estimation problem
Doutorado
Matematica Aplicada
Doutor em Matemática Aplicada
APA, Harvard, Vancouver, ISO, and other styles
46

Selistre, Luciano da Silva. "Nefropatia induzida por contraste após tomografia computadorizada." Pontifícia Universidade Católica do Rio Grande do Sul, 2009. http://hdl.handle.net/10923/4427.

Full text
Abstract:
Made available in DSpace on 2013-08-07T19:04:27Z (GMT). No. of bitstreams: 1 000423234-Texto+Completo-0.pdf: 1078063 bytes, checksum: 6a299e1c4b16d08e29d7fca46679d196 (MD5) Previous issue date: 2009
Contrast-induced nephropathy (CIN) is defined as worsening in renal function after administration of parenteral contrast and exclusiona of other causes. CIN is usually manifested as acute non-oliguric renal failures. Cases of CIN are usually defined by a fixed (0. 5 mg/dl) or proportionate (25%) rise in serum creatinine levels 24-48 hours after exposure to the contrast medium. Prevention strategies are based on the correction of factors leading to the development of CIN and are divided into choice of less nephrotoxic contrast (non-ionic); improvement in the patient’s clinical status through hydration; use of drugs that reduce renal vasoconstriction and oxidative stress; and temporary suspension of drugs with nephrotoxic potential or that are hamful in case of reduced glomerular filtration. This review aims on the management recommendations to prevent its occurrence.
A nefropatia por contraste (NIC) é definida como uma piora na função renal que se segue à administração de contraste parenteral, tendo sido excluídas outras causas. A NIC manifesta-se, usualmente, como uma insuficiência renal aguda não oligúrica. Por definição, deve haver um aumento na creatinina basal de 25-50% ou um aumento superior a 0,5 mg/dl de 24 a 48 horas após o uso vascular de contraste. As medidas de prevenção são baseadas na correção dos fatores que levam ao desenvolvimento da NIC e dividem-se em: escolha de agentes de contrastes menos nefrotóxicos (não-iônicos) e utilização de doses menores; melhora no estado clínico do paciente com hidratação; uso de drogas que reduzam vasoconstrição renal e estresse oxidativo; e suspensão temporária de drogas com potencial nefrotóxico ou prejudiciais, no caso de diminuição da filtração glomerular. Essa revisão tem o objetivo de examinar as principais recomendações de manejo para prevenir sua ocorrência.
APA, Harvard, Vancouver, ISO, and other styles
47

Francesco, Sílvia de. "Simulação e reconstrução em tomografia cardio-torácica." Doctoral thesis, Universidade de Aveiro, 2009. http://hdl.handle.net/10773/2219.

Full text
Abstract:
Doutoramento em Engenharia Electrotécnica
Esta dissertação aborda o tema da Tomografia Axial Computorizada com especial enfoque na reconstrução da imagem, ou seja, nos métodos matemáticos que, dado um conjunto de amostras da intensidade de radiação X transmitida, recolhidas segundo uma geometria de irradiação específica, permitem obter o mapa da distribuição tri-dimensional (3D) do coeficiente de atenuação linear no interior do objecto. Em termos mais formais, dado que, do ponto de vista matemático, o processo de aquisição dos dados corresponde à amostragem da transformada de Radon da função que descreve a distribuição do coeficiente de atenuação no volume sob estudo, estamos interessados nos métodos matemáticos que permitem calcular a transformada inversa de Radon a partir de conjuntos suficientemente densos de amostras. O ambiente de simulação utilizado, desenvolvido de forma a permitir a aquisição de amostras da transformada de Radon de um modelo digital dinâmico do tórax humano (4D MCAT) segundo qualquer uma das geometrias de amostragem actualmente em uso nos equipamentos modernos, permitiu a implementação e avaliação de novos métodos de reconstrução. Nomeadamente, são propostos novos métodos de reconstrução rápida baseados na teoria de Fourier e no cálculo da transformada de Fourier a partir de amostras não equiespaçadas, quer para geometria de aquisição paralela quer divergente, e é abordado o tema da reconstrução dinâmica sendo exploradas várias técnicas de reconstrução que permitem reduzir os efeitos do movimento nos estudos cardio-torácicos. Os estudos realizados permitem demonstrar que o desempenho dos métodos de Fourier propostos é equivalente, no que respeita à qualidade de imagem, ao desempenho do método de Retroprojecção Filtrada, habitualmente utilizado nos equipamentos comerciais mas a custos computacionais significativamente mais baixos.
This thesis addresses the theme of Computed Tomography, with special emphasis on tomographic reconstruction techniques, this means, the mathematical methods which, given a set of samples of transmitted radiation intensity, acquired with a specific sampling geometry, provide a threedimensional (3D) map of linear attenuation coefficient of the given object. Since, from a mathematical point of view, the acquisition process corresponds to the sampling of the Radon transform of the function describing the spatial distribution of attenuation coefficient in the volume under study, we are interested in methods and algorithms leading to diverse numerical implementations of the inverse Radon transform from sufficiently dense sets of samples. The developed simulation environment, capable to perform virtual acquisition of Radon transform’s samples of a digital anatomical model, in our case the dynamical digital model of human thorax (4D MCAT), through any of the sampling geometries currently used in commercial equipments, enabled the implementation and evaluation of new reconstruction methods. We propose new methods for fast reconstruction based on Fourier theory and on the calculation of Fourier transform for non-equispaced samples, both for parallel and for divergent acquisition geometries, and we deal with the topic of dynamic reconstruction, by exploring some reconstruction techniques capable of minimizing movement artifacts in cardio-thoracic images. The studies performed demonstrated that the performance of the proposed Fourier methods regarding image quality is similar to the Filtered Backprojection method, traditionally used in commercial equipments but at significantly lower computational costs.
APA, Harvard, Vancouver, ISO, and other styles
48

Smékal, Ondřej. "Restaurace obrazových dat z optické koherenční tomografie." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2012. http://www.nusl.cz/ntk/nusl-219497.

Full text
Abstract:
Restoration of image data has become an essential part of the processing of medical images obtained by any system. The same applies in the case of optical coherence tomography. The aim of this work is to study the first restoration methods. Second, the description of the data representation from optical coherence tomography and subsequent discussions that restoration methods based on deconvolution would potentially find application in processing of Optical coherence tomography. Finally, the third to create a program solution of the OCT data restoration process in MATLAB environment and followed by discussion of effectiveness of the presented solutions.
APA, Harvard, Vancouver, ISO, and other styles
49

Candrák, Matúš. "Zpracování difuzně vážených obrazů pořízených MR tomografem." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2014. http://www.nusl.cz/ntk/nusl-220983.

Full text
Abstract:
The semester thesis describes the basic principles of MRI, methods for measuring diffusion coefficients and creating DWI and DTI images. As a result a practical implementation of program was implemented in Matlab, based on theoretical knowledge of the problem.
APA, Harvard, Vancouver, ISO, and other styles
50

Kalasová, Dominika. "Využití fázového kontrastu v rentgenové počítačové tomografii." Master's thesis, Vysoké učení technické v Brně. Fakulta strojního inženýrství, 2016. http://www.nusl.cz/ntk/nusl-241843.

Full text
Abstract:
X-ray computed tomography is a nondestructive method for 3D imaging of inner structure of objects; it is, however, restricted by absorption properties of materials. With phase contrast imaging, observation of samples with low absorption or with parts with similar absorption becomes possible. For a long time, phase contrast imaging has been restricted to synchrotron radiation sources or special techniques due to requirement of spatial coherence of radiation. Along with recent development of X-ray micro and nanofocus tubes and X-ray detectors a phase contrast imaging becomes available also with laboratory sources. In this work an overview of phase contrast imaging methods is given, with an emphassis on propagation based method. Examples of this method and application of phase retrieval algorithm on samples from RIGAKU Nano3DX and GE phoenix v|tome|x L240 stations within Laboratory of X-ray micro and nanotomography CEITEC BUT are shown.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography