Academic literature on the topic 'Total Harmonic Distortion Analysis'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Total Harmonic Distortion Analysis.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Total Harmonic Distortion Analysis"

1

Muhammad, Salman, Basit2 Abdul, Ahmad Aemal, Syed Shah zeeshan, and Alam Kamran. "Modeling of Cascaded H-Bridge Multi-level Inverter Having Low Total Harmonic Distortion by using Equal Phase Distribution Method." International Journal of Engineering Works (ISSN: 2409-2770) 6, no. 03 (2019): 84–89. https://doi.org/10.5281/zenodo.2585862.

Full text
Abstract:
Multi-level inverters’ popularity over traditional inverters can be attributed to its low total harmonic distortion. Multi-level inverter is used both for high and low power applications. This study uses Equal phase method to analyze the total Harmonic distortion of 3, 5, 7 and 9 levels by using Cascaded H-Bridge configuration for such analysis. The total harmonic distortions of three, five, seven and nine levels are analyzed, studied and finally their output is compared through fast Fourier transform. Results are acquired by simulating Cascaded H-Bridge Multi-level inverter with MATLAB/
APA, Harvard, Vancouver, ISO, and other styles
2

Yogesh Kumar Lahre, Piyush Shrivas, Sakshi Tomar, and Diksha Komra. "Performance analysis of UPQC for total harmonic distortion." World Journal of Advanced Engineering Technology and Sciences 12, no. 1 (2024): 351–63. http://dx.doi.org/10.30574/wjaets.2024.12.1.0241.

Full text
Abstract:
In order to mitigate power quality (PQ) issues in electrical power systems, the Unified Power Quality Conditioner (UPQC) is the main topic of this research study. Power Quality problems, such as voltage sag, voltage swell, harmonics, and flicker, are brought on by the increase in nonlinear loads and the integration of renewable energy sources into traditional systems. Employing a variety of control algorithms and switching techniques, including as the SRF theory, hysteresis controllers, d-q theory of current, and traditional PI controllers, to balance the system, control voltage, and reduce ha
APA, Harvard, Vancouver, ISO, and other styles
3

Carvalho, Cesar Augusto Belchior, Genaro Mariniello da Silva, Bruna Cardoso Paz, et al. "Performance and Analysis of n-Type Vertically Stacked Nanowires Regarding Harmonic Distortion." Journal of Integrated Circuits and Systems 15, no. 2 (2020): 1–5. http://dx.doi.org/10.29292/jics.v15i2.202.

Full text
Abstract:
This paper studies the harmonic distortion (or non-linearity) of vertically stacked SOI nanosheets with different fin widths and channel lengths. The total harmonic distortion and third order harmonic distortion are used as figures of merit in this work. The four approaches applied verifies the correlation between the harmonic distortions and the variety of transistor’s dimensions available for analysis.
APA, Harvard, Vancouver, ISO, and other styles
4

Balkrishna, Mirajkar Nilesh, and Dr Rahul Kumar Budania. "Advanced Harmonic Analysis in Industrial Power Systems: Its Impact on Enhancing Power Quality and System Performance." INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT 08, no. 11 (2024): 1–7. http://dx.doi.org/10.55041/ijsrem38510.

Full text
Abstract:
This paper presents an advanced harmonic analysis of industrial power systems, focusing on its impact on enhancing power quality and system performance. The study investigates the harmonic distortions caused by nonlinear loads, particularly those introduced by Variable Frequency Drives (VFDs), in a manufacturing plant. Measurements of key electrical parameters, such as voltage, current, and Total Harmonic Distortion (THD), were recorded and analysed. The results reveal significant harmonic distortion levels, exceeding industry standards, which can lead to reduced equipment efficiency and poten
APA, Harvard, Vancouver, ISO, and other styles
5

Yatim, M. H., A. Ponniran, A. A. Bakar, A. N. Kasiran, K. R. Noor, and J. N. Jumadril. "Analysis of Symmetric and Asymmetric Multilevel Inverter Topologies Using Reduced Number of Switching Devices Circuit Structure." International Journal of Engineering & Technology 7, no. 4.30 (2018): 234. http://dx.doi.org/10.14419/ijet.v7i4.30.22127.

Full text
Abstract:
This paper presents symmetric and asymmetric multilevel inverter principles using reduced number of switching devices circuit structure. Principally, asymmetric multilevel inverter topology able to produce higher output voltage level without modification of the structure in order to reduce total harmonic distortion at the output voltage. In contrast, the number of switching devices need to be increased with symmetric principle when higher output voltage level is considered. In this study, 5-level reduced number of switching devices circuit structure is selected as a circuit configuration for s
APA, Harvard, Vancouver, ISO, and other styles
6

Adesina, Lambe Mutalub, Olalekan Ogunbiyi, Khalil D. Dalegan, and Ahmed B. Olaoye. "Assessment of Total Harmonic Distortion for Power Quality Improvement in Low Voltage Distribution Networks." Journal Of Engineering Research Innovation And Scientific Development 3, no. 1 (2025): 56–71. https://doi.org/10.61448/jerisd31256.

Full text
Abstract:
Ensuring high power quality in low-voltage distribution networks is crucial for efficient and reliable electricity supply. However, the increasing presence of nonlinear loads introduces harmonics into the power system network (PSN), leading to waveform distortions that degrade power quality. These harmonics, primarily generated by electronic devices, motors, generators, and transformers, contribute to power losses, system instability, and unbalanced load distribution at feeder pillars, ultimately affecting service delivery. This study aims to assess the Total Harmonic Distortion (THD) levels i
APA, Harvard, Vancouver, ISO, and other styles
7

Suresh, N., and Samuel Rajesh Babu R. "Reduction of Total Harmonic Distortion in Cascaded H-Bridge Inverter by Pattern Search Technique." International Journal of Electrical and Computer Engineering (IJECE) 7, no. 6 (2017): 3292–98. https://doi.org/10.11591/ijece.v7i6.pp3292-3298.

Full text
Abstract:
Pattern Search technique can be used to find the solution for the optimization problem. In this paper, pattern search algorithm has been utilized to calculate the switching angles for the cascaded H-bridge inverter with the consideration of minimizing total harmonic distortion. Mathematical equations for the optimization problem were formulated by fourier analysis technique. Lower order harmonics such as third, fifth, seventh, ninth and eleventh order harmonics were taken into account to mitigate the total harmonic distortion of the inverter. Simulations have been carried out for thirteen leve
APA, Harvard, Vancouver, ISO, and other styles
8

N., Suresh, and R. Samuel Rajesh Babu. "Reduction of Total Harmonic Distortion in Cascaded H-Bridge Inverter by Pattern Search Technique." International Journal of Electrical and Computer Engineering (IJECE) 7, no. 6 (2017): 3292. http://dx.doi.org/10.11591/ijece.v7i6.pp3292-3298.

Full text
Abstract:
Pattern Search technique can be used to find the solution for the optimization problem. In this paper, pattern search algorithm has been utilized to calculate the switching angles for the cascaded H-bridge inverter with the consideration of minimizing total harmonic distortion. Mathematical equations for the optimization problem were formulated by fourier analysis technique. Lower order harmonics such as third, fifth, seventh, ninth and eleventh order harmonics were taken into account to mitigate the total harmonic distortion of the inverter. Simulations have been carried out for thirteen leve
APA, Harvard, Vancouver, ISO, and other styles
9

Saad T. Y. Alfalahi. "Harmonic Distortion Analysis and Mitigation in an On-Grid Wind Farm using Passive Filters: A Case Study on the Shahat Distribution Network." Journal of Information Systems Engineering and Management 10, no. 44s (2025): 812–22. https://doi.org/10.52783/jisem.v10i44s.8661.

Full text
Abstract:
The numerous non-linear power electronic components in a wind energy conversion system (WECS) cause harmonic distortion, which diminishes the quality of the electricity produced. For WECS to function optimally with the power grid, these distortions must not exceed the limits established by international standards for total harmonic distortion (THD) in voltage and current waveforms. As required by current rules, this study looks at the harmonic distortion at the point of common coupling (PCC) between a planned 10.5 MW wind farm and the SHAHAT distribution network in northeastern Libya. MATLAB/S
APA, Harvard, Vancouver, ISO, and other styles
10

Al-Sharif, Yahya M., Gamal M. Sowilam, and Tamer A. Kawady. "Harmonic Analysis of Large Grid-Connected PV Systems in Distribution Networks: A Saudi Case Study." International Journal of Photoenergy 2022 (November 23, 2022): 1–14. http://dx.doi.org/10.1155/2022/8821192.

Full text
Abstract:
The increasing penetration of grid-connected PV rooftops at the distribution level still entails significant technical challenges affecting seriously the power quality indices such as harmonics and voltage fluctuations. Owing to the intermittent nature of renewable resources, the changing incident energy from renewables can generate considerable amounts of harmonics. Moreover, power electronic devices and nonlinear loads that are used frequently in the industry may exaggerate the harmonic distortions as well. Accordingly, utilizing suitable filtration techniques for harmonic reduction is cruci
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Total Harmonic Distortion Analysis"

1

Dey, Sourav. "Large-Signal Analysis of Buck and Interleaved Buck DC-AC Converters." Wright State University / OhioLINK, 2014. http://rave.ohiolink.edu/etdc/view?acc_num=wright1409578634.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Gokgoz, Sinan. "A Stand-alone Induction Powered Current And Current Harmonics Measurement System For Distribution Lines." Master's thesis, METU, 2012. http://etd.lib.metu.edu.tr/upload/12614967/index.pdf.

Full text
Abstract:
The presence of information and communication technologies in the field of energy is increasing every day. Smart grid subject which aims to increase the percentage of energy generation through renewable resources and to make consumers to be involved in grid actively, is gaining importance day by day. In order to provide an effcient and reliable operation of smart grid network, it is necessary to collect relevant parameters from network components via communication infrastructure and to evaluate collected information. Also, with the inclusion of distributed energy sources in the power lines, co
APA, Harvard, Vancouver, ISO, and other styles
3

Neužil, Jan. "Uživatelské rozhraní pro HP89410A." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2009. http://www.nusl.cz/ntk/nusl-217775.

Full text
Abstract:
The aim of this thesis was to develop user interface in LabVIEW to make typical measurements with spectral analyzer HP89410A There is introduced the theory of operation of an analogue heterodyne and a digital FFT spectral analyzer. It is explained the background of the Fast Fourier Transform. There are discussed the key settings in measuring with FTT analyzer, like window function, bandwidth, number of frequency points, or the averaging. Further is described the program, which was developed for measuring frequency characteristic by white noise and by stepped measurement. It was also made a mod
APA, Harvard, Vancouver, ISO, and other styles
4

Lee, J. H. "Two-dimensional modelling and harmonic distortion analysis of bipolar transistors." Thesis, Brunel University, 1986. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.356585.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Gedo, Christopher N. "Computer analysis of harmonic distortion in electrical power distribution systems." Thesis, Monterey, California. Naval Postgraduate School, 1991. http://hdl.handle.net/10945/28056.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Duggan, E. "Measurement, analysis and mathematical modelling of harmonic distortion in power systems." Thesis, Staffordshire University, 1990. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.232907.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Tella, Pranavi Chowdari Islam Naz E. "The study of single phase diode rectifiers with high power factor and low total harmonic distortion." Diss., Columbia, Mo. : University of Missouri--Columbia, 2008. http://hdl.handle.net/10355/5677.

Full text
Abstract:
The entire thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file; a non-technical public abstract appears in the public.pdf file. Title from PDF of title page (University of Missouri--Columbia, viewed on October 6, 2009). Thesis advisor: Dr. Naz E. Islam. Includes bibliographical references.
APA, Harvard, Vancouver, ISO, and other styles
8

West, Edward G. S. M. Massachusetts Institute of Technology. "Analysis of harmonic distortion in an Integrated Power System for naval applications." Thesis, Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/33594.

Full text
Abstract:
Thesis (Nav. E.)--Massachusetts Institute of Technology, Dept. of Ocean Engineering; and, (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2005.<br>Includes bibliographical references (p. 89-91).<br>This research quantifies the voltage distortion over the broad range of operating conditions experienced by a Naval warship. A steady state model of an Integrated Power System (IPS) was developed in a commercially available power system simulation tool. The system chosen for this study was a three-phase, 4160 VAC, 80 MW power system with a 450 VAC
APA, Harvard, Vancouver, ISO, and other styles
9

Negumbo, Rosalia. "Analysis for electrical energy and overall efficiency in distribution networks with harmonic distortion." Thesis, Cape Peninsula University of Technology, 2009. http://hdl.handle.net/20.500.11838/1103.

Full text
Abstract:
Thesis (MTech (Electrical Engineering))--Cape Peninsula University of Technology, 2009<br>Traditionally, harmonics are ignored in overall efficiency and energy usage studies. However, in the modern era, power systems contain levels of harmonics which can no longer be ignored by engineers, planners, energy conservationists and economists. The directions of power flows have to be considered when harmonics are present in the power network. A methodology and new formulae for individual and overall efficiency and energy usage is developed at each frequency (f1, h and H) and forms the main co
APA, Harvard, Vancouver, ISO, and other styles
10

Collins, Christopher Donald. "FACTS device modelling in the harmonic domain." Thesis, University of Canterbury. Electrical and Computer Engineering, 2006. http://hdl.handle.net/10092/1103.

Full text
Abstract:
This thesis describes a novel harmonic domain approach for assessing the steady state performance of Flexible AC Transmission System (FACTS) devices. Existing harmonic analysis techniques are reviewed and used as the basis for a novel iterative harmonic domain model for PWM FACTS devices. The unified Newton formulation adopted uses a combination of positive frequency real valued harmonic and three-phase fundamental frequency power-flow mismatches to characterise a PWM converter system. A dc side mismatch formulation is employed in order to reduce the solution size, something only possible beca
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Total Harmonic Distortion Analysis"

1

Gedo, Christopher N. Computer analysis of harmonic distortion in electrical power distribution systems. Naval Postgraduate School, 1991.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

D, Baust Henry, Agrell Johan, and NASA Glenn Research Center, eds. Management of total pressure recovery, distortion and high cycle fatigue in compact air vehicle inlets. National Aeronautics and Space Administration, Glenn Research Center, 2002.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Tenney, James. John Cage and the Theory of Harmony. Edited by Larry Polansky, Lauren Pratt, Robert Wannamaker, and Michael Winter. University of Illinois Press, 2017. http://dx.doi.org/10.5406/illinois/9780252038723.003.0012.

Full text
Abstract:
James Tenney examines some of John Cage's theoretical ideas and their possible implications for a new theory of harmony that he argues requires new definitions of “harmony,” “harmonic relations,” etc.; such definitions, he contends, will emerge from a more careful analysis of the “total soundspace” of musical perception. Tenney begins with a discussion of the current disparity between harmonic theory and compositional practice before explaining what a true theory of harmony should be: a theory of harmonic perception (one component in a more general theory of musical perception) consistent with
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Total Harmonic Distortion Analysis"

1

Petružela, Michal, Vojtěch Blažek, and Jan Vysocký. "Analysis of Appliance Impact on Total Harmonic Distortion in Off-Grid System." In Lecture Notes in Electrical Engineering. Springer International Publishing, 2019. http://dx.doi.org/10.1007/978-3-030-14907-9_81.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Reddy, K. M. N. Chaitanya Kumar, N. Kanagasabai, and N. Gireesh. "BLDC Motor and Its Speed Characteristics Analysis Based on Total Harmonic Distortion." In Advances in Cognitive Science and Communications. Springer Nature Singapore, 2023. http://dx.doi.org/10.1007/978-981-19-8086-2_89.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Rohit, Repalle, and Gudipati Kishor. "Performance Analysis of Grid-Connected Photovoltaic Inverter Based on the Total Harmonic Distortion." In Proceedings of the International Conference on Computational Innovations and Emerging Trends (ICCIET 2024). Atlantis Press International BV, 2024. http://dx.doi.org/10.2991/978-94-6463-471-6_6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Weik, Martin H. "total harmonic distortion." In Computer Science and Communications Dictionary. Springer US, 2000. http://dx.doi.org/10.1007/1-4020-0613-6_19767.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Devi, Niharika, and Pranabjyoti Haloi. "Simulation of symmetrical conventional cascaded H bridge seven level inverter using LC filter with different PWM techniques for minimization of total harmonic distortion." In Intelligent Computation and Analytics on Sustainable Energy and Environment. CRC Press, 2024. http://dx.doi.org/10.1201/9781003540199-9.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Zhang, Xueyuan, and Dominik Moosbauer. "Application of Harmonic and Total Harmonic Distortion Instrumentation in Corrosion." In Advances in Electrochemical Techniques for Corrosion Monitoring and Laboratory Corrosion Measurements. ASTM International, 2019. http://dx.doi.org/10.1520/stp160920170220.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Chothani, Nilesh, Maulik Raichura, and Dharmesh Patel. "Total Harmonic Distortion-Based Improved Transformer Protective Scheme." In Studies in Infrastructure and Control. Springer Nature Singapore, 2023. http://dx.doi.org/10.1007/978-981-99-3870-4_6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Afanas’eva, Elena, and Anatoly Golberg. "Topological mappings of finite area distortion." In Harmonic Analysis and Partial Differential Equations. Springer Nature Switzerland, 2023. http://dx.doi.org/10.1007/978-3-031-25424-6_2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Aala Kalananda, Vamsi Krishna Reddy, and Venkata Lakshmi Narayana Komanapalli. "Enhanced Krill Herd Optimization Algorithm: Total Harmonic Distortion Minimization." In Advances in Automation, Signal Processing, Instrumentation, and Control. Springer Singapore, 2021. http://dx.doi.org/10.1007/978-981-15-8221-9_226.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Baldoni-Silva, Velleda, and Michèle Vergne. "Morris identities and the total residue for a system of type A r." In Noncommutative Harmonic Analysis. Birkhäuser Boston, 2004. http://dx.doi.org/10.1007/978-0-8176-8204-0_1.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Total Harmonic Distortion Analysis"

1

Fouda, Tarek. "Total Harmonic Distortion (THD) Analysis of 5-Level and 7-Level Cascaded Multilevel Inverters at Different Switching Frequencies." In 2024 25th International Middle East Power System Conference (MEPCON). IEEE, 2024. https://doi.org/10.1109/mepcon63025.2024.10850392.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Kus, Slawomir, Sridhar Srinivasan, Kwei Meng Yap, et al. "On-Line, Real Time Electrochemical Corrosion Monitoring in Low Conductive Fluids – Sulfolane Aromatic Extraction." In CORROSION 2018. NACE International, 2018. https://doi.org/10.5006/c2018-11065.

Full text
Abstract:
Abstract Electrochemical corrosion monitoring techniques such as Linear Polarization Resistance (LPR), Electrochemical Noise (ECN) or Harmonic Analysis are widely recognized for their responsiveness and accuracy for determination of instantaneous corrosion rate. However, field application has generally been limited by the need for a conductive / aqueous process environment. This limitation stems from the fact that electrochemical systems cannot provide reliable readings in media at conductance levels less than 10μS/cm due to significant impact of solution resistance on measured values of total
APA, Harvard, Vancouver, ISO, and other styles
3

Aslan, Harun Fecri, and Murtaza Farsadi. "Total Harmonic Distortion Reduction in Three-Phase PV Inverters." In 2024 13th International Conference on Renewable Energy Research and Applications (ICRERA). IEEE, 2024. https://doi.org/10.1109/icrera62673.2024.10815230.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Jain, Rakhee, and Dheeraj Agrawal. "Total Harmonic Distortion of Multifunctional Converter for Electric Vehicles." In 2024 IEEE 2nd International Conference on Innovations in High Speed Communication and Signal Processing (IHCSP). IEEE, 2024. https://doi.org/10.1109/ihcsp63227.2024.10959782.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Maile, Phemelo, and Sampath Jayalth. "Foreign Object Detection Using Total Harmonic Distortion of Input Current." In 2025 IEEE Wireless Power Technology Conference and Expo (WPTCE). IEEE, 2025. https://doi.org/10.1109/wptce62521.2025.11062129.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Kalbat, Abdulrahman. "PSCAD simulation of grid-tied photovoltaic systems and Total Harmonic Distortion analysis." In 2013 3rd International Conference on Electric Power and Energy Conversion Systems (EPECS). IEEE, 2013. http://dx.doi.org/10.1109/epecs.2013.6713002.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Reddy Sudharshana, K., V. Muralidhara, A. Ramachandran, and R. Srinivasan. "Analysis of Total Harmonic Distortion in 5-level Inverter fed Induction Motor." In 2018 International Conference on Computing, Power and Communication Technologies (GUCON). IEEE, 2018. http://dx.doi.org/10.1109/gucon.2018.8674891.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Li Yalu and Liu Min. "Analysis of Influence of DAC on Total Harmonic Distortion in Digital Waveform Synthesis." In 2007 8th International Conference on Electronic Measurement and Instruments. IEEE, 2007. http://dx.doi.org/10.1109/icemi.2007.4351077.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Sharma, Piyush, Dheeraj K. Dhaked, Sachin Saini, Love K. Tripathi, and Ashish Shrivastva. "Analysis of Different Converters for Reduced Total Harmonic Distortion and Improved Power Factor." In 2018 5th International Conference on Signal Processing and Integrated Networks (SPIN). IEEE, 2018. http://dx.doi.org/10.1109/spin.2018.8474197.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Thakre, M. P., S. Shinde Sayali, and Jain A. M. "Stability and Total Harmonic Distortion Analysis with Performance of Grid-Tied PV Systems." In 2020 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS). IEEE, 2020. http://dx.doi.org/10.1109/icpects49113.2020.9337036.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Total Harmonic Distortion Analysis"

1

Torres, Marissa, and Norberto Nadal-Caraballo. Rapid tidal reconstruction with UTide and the ADCIRC tidal database. Engineer Research and Development Center (U.S.), 2021. http://dx.doi.org/10.21079/11681/41503.

Full text
Abstract:
The quantification of storm surge is vital for flood hazard assessment in communities affected by coastal storms. The astronomical tide is an integral component of the total still water level needed for accurate storm surge estimates. Coastal hazard analysis methods, such as the Coastal Hazards System and the StormSim Coastal Hazards Rapid Prediction System, require thousands of hydrodynamic and wave simulations that are computationally expensive. In some regions, the inclusion of astronomical tides is neglected in the hydrodynamics and tides are instead incorporated within the probabilistic f
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!