Academic literature on the topic 'Transformateur à air'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Transformateur à air.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Transformateur à air"

1

Widyastuti, Christine, Tasdik Darmana, and Oktaria Handayani. "PENGARUH KADAR AIR TERHADAP TEGANGAN TEMBUS MINYAK TRANSFORMATOR DISTRIBUSI." Energi & Kelistrikan 10, no. 2 (January 28, 2019): 129–36. http://dx.doi.org/10.33322/energi.v10i2.232.

Full text
Abstract:
Abstract Transformer oil is one of the liquid insulating materials that functions as insulation and cooling in the transformer. Some oil insulation materials must have the ability to withstand penetrating stresses, while as a transformer oil cooler must be able to reduce the heat generated, so that with these two capabilities transformer oil is expected to be able to protect the transformer from interference. Examination of breakdown stress using the IEC 60156-1995 method. For evaluation of oil on the power transformer determines the water content. The feasibility of transformer oil uses breakdown voltage and water content testing as a result of feasibility simulations based on international standards to improve reliability in the treatment of power transformers in the industrial world especially for community service. With greater breakdown voltage, it proves that the oil is still suitable for use. Whereas if the oil water content is higher, it proves that the oil is not suitable for use. Transformer oil, according to the PLN (SPLN) test standards 49-1 / 1992, must have a 30kV / 2.5mm breakdown voltage. In the study of sample A and sample B it has a breakdown voltage of 14kVA and 18kVA. With this, sample A and sample B are not suitable for use. Keywords: moisture content, transformer oil, breakdown voltage, SPLN 49-1 / 1992 ABSTRAK Minyak transformator merupakan salah satu bahan isolasi cair yang berfungsi sebagai isolasi dan pendingin pada transformator. Sebagian bahan isolasi minyak harus memiliki kemampuan untuk menahan tegangan tembus, sedangkan sebagai pendingin minyak transformator harus mampu meredam panas yang ditimbulkan, sehingga dengan kedua kemampuan ini maka minyak transformator diharapkan mampu melindungi transformator dari gangguan. Pengujian tegangan tembus menggunakan metode IEC 60156-1995. Untuk evaluasi minyak pada transformator daya menentukan kadar air. Kelayakan minyak transformator menggunakan pengujian tegangan tembus dan kadar air sebagai hasil simulasi kelayakan berdasarkan standar internasional untuk meningkatkan kehandalan dalam perawatan transformator daya dalam dunia industri khususnya terhadap pelayanan masyarakat. Dengan tegangan tembus yang semakin besar membuktikan minyak tersebut masih layak pakai. Sedangkan apabila kadar air minyak tersebut semakin tinggi membuktikan minyak tersebut sudah tidak layak pakai. Minyak transformator, sesuai standar uji PLN (SPLN) 49-1/1992 harus memiliki tegangan tembus 30kV/2,5mm. Dalam penelitian dari sampel A dan sampel B memiliki tegangan tembus sebesar 14kVA dan 18kVA. Dengan ini, sampel A dan sampel B tidak layak pakai. Kata kunci: kadar air, minyak trafo, tegangan tembus, SPLN 49-1/1992
APA, Harvard, Vancouver, ISO, and other styles
2

Irawan, Bambang, and Wahri Sunanda. "UNJUK KERJA TRANSFORMATOR DAYA PADA GARDU INDUK SISTEM KELISTRIKAN PULAU BANGKA." Transmisi 22, no. 2 (June 30, 2020): 51–55. http://dx.doi.org/10.14710/transmisi.22.2.51-55.

Full text
Abstract:
Efisiensi transformator dapat didefinisikan sebagai perbandingan antara daya listrik keluaran dengan daya listrik yang masuk pada transformator. Oleh karenanya akan dianalisis pengaruh perubahan beban terhadap efisiensi dan rugi-rugi transformator daya di gardu induk Air Anyir, gardu induk Pangkalpinang dan gardu induk Sungailiat. Hasil analisis yang didapatkan pada transformator daya gardu induk Air Anyir pembebanan tertinggi 13.36 MW dengan efisiensi 99.62 % dan rugi total 49.46 kW serta pembebanan terendah sebesar 2.37 MW dengan efisiensi 96.65 % dan rugi total 38.83 kW. Pada tranformator daya gardu induk Pangkalpinang pembebanan tertinggi 17,38 MW dengan efisiensi 99.69 % dan rugi total 61.64 kW serta pembebanan terendah 11.93 MW dengan efisiensi 99.65 % dan rugi total 41.22 kW. Pada transformator daya gardu induk Sungailiat pembebanan tertinggi 12.98 MW dan efisiensi 99.65 %, dan rugi total 45.61 kW sedangkan pembebanan terendah 2.06 MW dengan efisiensi 97.46% dan rugi total 23.88 kW
APA, Harvard, Vancouver, ISO, and other styles
3

Suryadi, Aris. "DAMPAK HARMONISA TERHADAP PENINGKATAN TEMPERATUR TRANSFORMATOR DISTRIBUSI 1000 kVA DI POLITEKNIK ENJINERING INDORAMA." Simetris : Jurnal Teknik Mesin, Elektro dan Ilmu Komputer 8, no. 2 (November 1, 2017): 421. http://dx.doi.org/10.24176/simet.v8i2.1187.

Full text
Abstract:
Transformator distribusi memiliki peran penting dalam mendistribusikan tenaga listrik sehingga peran transformator ini untuk beroperasi dengan baik harus dalam kondisi stabil. Salah satu kondisi yang mengganggu beroperasinya adalah gangguan harmonisa yang terjadi pada sistem distribusi tenaga listrik akibat terjadinya distorsi gelombang arus dan tegangan.Kandungan harmonisa yang tinggi pada jaringan sistem tenaga listrik akan menyebabkan transformator distribusi mengalami temperatur berlebih dan apabila tidak segera ditangani maka usia pengoperasian transformator lebih singkat.Salah satu perangkat yang dapat merusak transformator distribusi adalah beban non-linear, diantaranya yang terdapat pada Kampus Politeknik Enjinering Indorama sebagai sebagian penyumbang harmonisa yang terjadi seperti komputer, refrigerator, air conditioning disetiap ruang kelas, peralatan elektronika laboratorium, serta adjustable speed drive (ASD) yang terdapat pada unit mesin Drawn Texture Yarn (DTY).Penelitian ini dilakukan untuk mengetahui harmonisa dan pengaruhnya terhadap peningkatan temperatur pada transformator distribusi 1000 kVA yang terdapat di area Politeknik Enjinering Indorama dengan cara melakukan pengukuran harmonisa pada transformator distribusi dalam keadaan berbeban. Pembebanan transformator sesuai dengan beban operasional dalam melaksanakan kegiatan akademik dan admistratif serta laboratorium.Kata kunci: harmonisa, temperatur, transformator
APA, Harvard, Vancouver, ISO, and other styles
4

Jumardin, Jumardin, Jumiati Ilham, and Sardi Salim. "Studi Karakteristik Minyak Nilam Sebagai Alternatif Pengganti Minyak Transformator." Jambura Journal of Electrical and Electronics Engineering 1, no. 2 (October 30, 2019): 40–48. http://dx.doi.org/10.37905/jjeee.v1i2.2881.

Full text
Abstract:
Isolasi minyak umumnya menggunakan minyak mineral karena memiliki penyerapan panas yang baik dan karakteristik dielektrik sebagai isolator. Karena minyak mineralnya yang semakin lama semakin berkurang dan kurang ramah lingkungan, sangat penting mencari solusi untuk mengatasinya. Penelitian ini bertujuan untuk mengetahui karakteristik minyak nilam sebagai alternatif pengganti minyak Transformator. Penelitian ini menggunakan beberapa macam pengujian diantaranya kadar asam, kadar air, viskositas dan mengetahui pengaruh tegangan tembus. Hasil pengujian tegangan tembus minyak nilam belum memenuhi standar sebagai alternatif pengganti minyak transformator di mana tegangan tembus dengan menggunakan elektroda stengah bola yakni 15, 89 kV. Selanjutnya hasil pengujian kadar asam, kadar air dan viskositas ditemukan bahwa nilai pengujian kadar asam 35,344 mg/kg, kadar air 58.596 mg/kg dan viskositas 33. 16 cst.. syarat minyak transformator harus memenuhi standar SPLN 49- 1: 1982 dan IEC 60296-2003. Dalam penelitian ini minyak nilam belum memenuhi memenuhi standar IEC 60296-2003. SPLN 49-1
APA, Harvard, Vancouver, ISO, and other styles
5

Ondrialdi, Rifky, Usaha Situmeang, and Zulfahri. "Analisis Pengujian Kualitas Isolasi Transformator Daya di PT. Indah Kiat Pulp and Paper Perawang." SainETIn 4, no. 2 (June 30, 2020): 72–81. http://dx.doi.org/10.31849/sainetin.v4i2.6288.

Full text
Abstract:
Degradasi isolasi/penuaan merupakan salah satu penyebab utama kerusakan transformator. Bagian terlemah dari sistem isolasi adalah kerentanan terhadap kadar air, oksigen, terhadap panas berlebih dan tekanan mekanis. Pemburukan atau kegagalan isolasi dapat menyebabkan kegagalan operasi atau bahkan kerusakan transformator. Salah satu metode untuk mengetahui kondisi isolasi adalah dengan melakukan pengujian pengujian power factor (PF) atau Dissipation factor (DF) isolasi dan pengujian rasio belitan. Pengujian ini dilakukan berdasarkan standart IEEE C57.152-2013 dimana nilai standar pengujian 0,5 % dalam keadaan baik, apabila melebihi dari 0,5 % dianggap mengalami pemburukan. Nilai pengujian PF/DF untuk transformator IP954-T01 adalah 0,243 % masih kecil dari standart 0,5 % yang mengidentifikasi kondisi isolasi masih bagus. Sedangkan untuk pengujian PF/DF transformator IP254-T02 adalah 0,655 % lebih besar dari 0,5 % yang mengidentifikasi terjadinya penurunan kualitas isolasi. Pengujian PF/DF isolasi minyak untuk transformator IP954-T01 hasil uji dari tegangan 10 kV adalah 0,054 % dan IP254-T02 hasil uji dari tegangan 10 kV adalah 0,144 % masih kecil dari 0,5 % yang mengidentifikasi kualitas isolasi minyak masih bagus. Untuk hasil pengujian ratio belitan/tegangan untuk transformator IP954-T01 nilai persen deviasi belitan pada posisi Tap changer 3 bernilai 0,288 %, persen devisiasi masih kecil dari 0,5%. Sedangkan transformator IP254-T02 nilai pada posisi Tap changer 3 bernilai 1,440 % besar dari 0,5 % mengindikasikan adanya masalah pada belitan.
APA, Harvard, Vancouver, ISO, and other styles
6

Jurnal, Redaksi Tim. "PENGARUH PENAMBAHAN PENDINGIN AIR PADA TRANSFORMATOR DAYA UNTUK PEMBEBANAN." Energi & Kelistrikan 9, no. 1 (November 26, 2018): 8–15. http://dx.doi.org/10.33322/energi.v9i1.55.

Full text
Abstract:
Power transformers are one of the important equipment in the electric power system. Power transformers are devices with the largest investment in a transmission and distribution substations. Currently, the use of power transformers at Marunda substations on average has reached 80% of rated load. Then require maximum of cooling transformers, to restrain the rate of the winding and oil temperature rise. Result of the research were obtained with the addition of water cooling at power transformers can be reduce the heat due to the high ambient temperatures. The results showed a decrease in temperature of 3°C, so can be used to add transformers loading of 2,51 MW. While of water consumption was 2,052 m3 per day.
APA, Harvard, Vancouver, ISO, and other styles
7

Pratama, Fajar Ramadhan, and Peby Wahyu Purnawan. "Perancangan Sistem Kendali Temperature Suhu dan Level Oil Pada Prototype Transformator Tenaga." TELKA - Telekomunikasi Elektronika Komputasi dan Kontrol 6, no. 2 (November 24, 2020): 85–92. http://dx.doi.org/10.15575/telka.v6n2.85-92.

Full text
Abstract:
Dalam beberapa transformator yang terdapat di unit gardu induk PLN sering terjadi peningkatan temperatur suhu oil secara drastis dikarenakan kurang efektif dalam metode sistem pendinginan. Selain itu sering terjadi kebocoran kecil pada penutup atau sambungan tangki transformator yang mengakibatkan menurunnya level oil pada transformator yang dapat membuat kerusakan pada transformator tersebut. Makalah ini membahas rancangan sebuah prototype sistem kendali suhu oil (dimana oil di ganti dengan air keran) yang dapat mengendalikan temperatur suhu oil pada tangki transformator agar tidak terjadi overheat dengan mengatur kecepatan putaran kipas dan kendali level oil yang dapat menjaga level oil dalam kondisi selalu full. Sistem yang dirancang terdiri dari mikrokontroler Arduino Nano, sensor DS18B20, sensor DHT22, kipas pendingin, sensor level 1, sensor level 2, pompa pengisian, LCD (Liquid Cyrstal Display). Dalam sistem kendali suhu oil dengan metode fuzzy terdapat 2 inputan yaitu suhu oil dan suhu udara yang difuzzyfikasi menjadi 5 membership function dengan output nilai kecepatan untuk mengatur putaran kipas. Metode Defuzzyfikasi yang digunakan adalah WAA (Weighted Average Area). Hasil yang didapatkan suhu oil transformator stabil pada suhu 40°C - 41°C sehingga peralatan transformator tidak akan cepat rusak dan pembebanan akan lebih efektif. Sementara itu, hasil kendali level oil selalu dalam kondisi Full sehingga transformator tidak akan padam dikarenakan level oil kurang. Sometimes, the transformers in the PLN Substation Unit has common problem such as the increases of oil temperature since ineffective method in cooling system. As well as frequent small leaks in the cover or connection of the transformer tank resulting in a decrease in the oil level in the transformer which can cause damage to the transformer. This paper describe a design of system prototype for an oil temperature control system which can control the temperature of the oil temperature in the transformer tank so that there is no overheating. The controlling is by adjusting the fan speed and control the oil level which can keep the oil level in full condition. The system designed consists of an Arduino Nano microcontroller, DS18B20 sensor, DHT22 sensor, cooling fan, level 1 sensor, level 2 sensor, filling pump, LCD (Liquid Cyrstal Display). We used a fuzzy logic method in oil temperature control. There are 2 inputs, namely the oil temperature and air temperature which are fuzzyfied into 5 membership functions with the output speed values to regulate fan rotation. We used Weighted Average Area (WAA) for defuzzyfication process. Based on the results, we obtained that the transformer oil temperature is stable at a temperature of 40° C - 41° C so that the transformer equipment will not be damaged quickly and the loading will be more effective. Furthermore, the results of the oil level control are always in full condition so that the transformer will not go out because the oil level is not enough.
APA, Harvard, Vancouver, ISO, and other styles
8

Yanto, I. Putu Eka April, I. A. Dwi Giriantari, and W. G. Ariastina. "Perencanaan Sistem Kelistrikan PLTMH Banjar Dinas Mekar Sari." Majalah Ilmiah Teknologi Elektro 20, no. 1 (March 1, 2021): 37. http://dx.doi.org/10.24843/mite.2021.v20i01.p04.

Full text
Abstract:
Intisari— Artikel ini mengemukakan tentang desain ulang Pembangkit Listrik Tenaga Mikrohidro (PLTMH) di Banjar Dinas Mekar Sari, Desa Panji, Kecamatan Sukasada, Kabupaten Buleleng, Bali. PLTMH tersebut telah beroperasi sejak tahun 1980, dengan memanfaatkan aliran air Sungai Tukad Pasut. Investigasi awal menunjukkan adanya penurunan kapasitas produksi PLTMH karena kurangnya perawatan. Selain itu, desain awal PLTMH tersebut belum mengadopsi sistem kontrol yang modern, sehingga mengakibatkan produksi listrik yang tidak efisien. Rancangan baru untuk PLTMH di Banjar Dinas Mekar Sari menggunakan turbin crossflow untuk mengakomodasi laju aliran air 1,32 m3/detik dan dengan tinggi head efektif 16 m. Energi mekanik turbin dikopel ke generator melalui sistem kopel belt dengan panjang sabuk 3099 mm. Diameter pulley adalah 750 mm untuk sisi turbin, dan 149 mm untuk sisi generator. Kapasitas generator adalah 185 kVA, 50 Hz, 230/400 V, 1500 rpm, dan dengan efisiensi 94%. Electronic Load Controller memiliki kapasitas 180 kW, dengan 6 ballast load 30 kW. Sambungan dari generator ke transformator menggunakan kabel bawah tanah NYFGbY 4 × 95 mm2, dengan panjang 69 m. Transformator berjenis step-up/step-down dengan kapasitas 250 kVA.
APA, Harvard, Vancouver, ISO, and other styles
9

Fauzani, Fazahaqi Nahr, Karnoto Karnoto, and Tejo Sukmadi. "PERANCANGAN DAN ANALISIS PEMILIHAN SUMBER ENERGI LISTRIK PADA RUMAH POMPA BANDARA AHMAD YANI SEMARANG MENGGUNAKAN PROGRAM ETAP 12.6." TRANSIENT 7, no. 4 (May 25, 2019): 957. http://dx.doi.org/10.14710/transient.7.4.957-964.

Full text
Abstract:
Kelangsungan energi listrik pada sebuah instalasi listrik adalah hal yang sangat penting. Pada sistem instalasi pompa air Bandara Ahmad Yani Semarang, dibutuhkan sebuah sistem energi utama dan cadangan yang dapat mengasut semua motor yang diperlukan dalam kondisi apapun. Apabila terjadi gangguan listrik dan pompa air tidak dapat berjalan, maka seluruh operasional bandara akan terganggu. Tugas akhir ini akan menentukan peralatan yang dibutuhkan oleh instalasi yaitu dengan metode penentuan daya reaktif total dan penentuan arus yang mengalir. Sehingga peralatan yang digunakan untuk sistem energi utama yaitu transformator dengan kapasitas 1600 dan 2000 kVA, yang dihubungkan dengan kabel N2XFGbY 3x (2x300 mm2) dengan Variasi pertama menggunakan CB Cutler-Hammer RW 3 Pole sedangkan variasi kedua menggunakan CB ABB F2L 3 Pole. Sistem energi cadangan yaitu satu buah generator Perkins 45 kVA, dengan kabel penghantar N2XFGbY 2x10mm2 dan CB Cutler-Hammer EGB 3 Pole. Dua buah generator Perkins 1500 kVA, dengan kabel penghantar N2XFGbY 3x (2x300 mm2) dan CB Cutler-Hammer HNW 3 Pole. Tiga buah generator Perkins 1250 kVA, dengan kabel penghantar N2XFGbY 3x (2x300 mm2) dan CB Cutler-Hammer HNW 3 Pole. Penentuan kapasitas generator, transformator, CB, kabel sudah sesuai dengan standar yang berlaku
APA, Harvard, Vancouver, ISO, and other styles
10

Yuhendri, Muldi, Aswardi Aswardi, and Ahyanuardi Ahyanuardi. "Implementasi Pompa Air Tenaga Surya Menggunakan Inverter Boost Satu Fasa." INVOTEK: Jurnal Inovasi Vokasional dan Teknologi 20, no. 3 (October 30, 2020): 1–10. http://dx.doi.org/10.24036/invotek.v20i3.813.

Full text
Abstract:
Pompa air tenaga surya adalah salah satu alternatif penyediaan air bersih untuk daerah yang belum terjangkau jaringan listrik. Pompa air tenaga surya membutuhkan peralatan yang dapat menaikan tegangan panel surya sesuai dengan rating tegangan motor pompa air dan inverter untuk mengkonversikan tegangan dc panel surya menjadi tegangan ac sesuai dengan tegangan motor pompa air. Paper ini mengusulkan inverter boost satu fasa untuk pompa air tenaga surya yang dapat menaikan sekaligus mengkonversikan tegangan dc menjadi tegangan ac tanpa menggunakan transformator. Modulasi inverter dirancang menggunakan metode Sinusoidal Pulse Width Modulation (SPWM) yang diimplementasikan dengan arduino uno. Pompa air tenaga surya diimplementasikan untuk penyediaan air bersih di Mesjid dengan menggunakan panel surya 300 WP. Hasil pengujian di lapangan menunjukan bahwa pompa air tenaga surya yang diusulkan telah bekerja dengan baik sesuai dengan yang diharapkan. Inverter boost satu fasa yang diusulkan telah dapat mengkonversikan tegangan panel surya sesuai dengan rating tegangan motor pompa air.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Transformateur à air"

1

Wanderoild-Morand, Yohan. "Enfouissement d’une alimentation isolée sous contraintes de température et d’isolation." Thesis, Lyon, 2018. http://www.theses.fr/2018LYSE1193/document.

Full text
Abstract:
Certaines applications haute température telles que le forage, l’aéronautique ou l’aérospatial, amènent à repenser la conception des alimentations isolées permettant la commande des éléments de puissance. Ce mémoire s’articule autour de l’étude de la faisabilité et de l’enfouissement d’un convertisseur isolé possédant une forte isolation statique (10kV) et dynamique (<10 pF), pouvant travailler sous de hautes températures (>250°C), dans les gammes de tension de sortie de la dizaine de volts et de puissance de l’ordre du Watt. Pour ne pas être contraint par la température de Curie d’un matériau magnétique, cette alimentation DC/DC se base sur un transformateur à air. Dans un premier temps, cette thèse détaille l’origine, la mesure et l’estimation des éléments du modèle électrique choisi pour le transformateur. Ensuite, afin de maximiser la transmission de puissance, nous constituons un système résonnant en ajoutant des condensateurs en parallèle ou en série avec le transformateur, puis nous développons une méthode permettant d’accorder l’ensemble. La comparaison entre les topologies nous amène ensuite à choisir compensation série-série. Puis nous constatons que la technologie choisie pour les condensateurs, la contrainte d’isolation statique et dynamique peuvent diviser par plus de deux la puissance transmise au travers d’une surface. Enfin, nous abordons comment redresser et réguler la tension de sortie sans affecter la résonnance ou l’isolation apportée, tout en minimisant les pertes générées. Une dernière partie montre que, moyennant un système de dissipation un processus de fabrication adapté, il est possible d’intégrer la structure complète sur silicium
High temperature applications such as deep drilling, aeronautics or aerospace, lead to rework the isolated power supplies used for the control of the power elements. This work study the feasibility of an embedded converter with high static (10kV) and dynamic (<10 pF) insulation, able to work under high temperatures (> 250 ° C), in the ranges of dozens volts for the output voltage and several Watt of transmitted power. To avoid being constrained by a magnetic material Curie temperature of, we use a coreless transformer based DC/DC power supply. First of all, this thesis details the origin, the measurement and the estimation of the elements of the chosen transformer electric model. Then, to maximize the transferred power, we form a resonant structure by adding capacitors in parallel or in series with the transformer, then we develop a method to tune the whole. The comparison between the topologies leads us to choose a serial-serial compensation. Then we note that the technology chosen for capacitors, the static and dynamic insulation constraint can divide by more than two the power transmitted through a surface. Finally, we discuss how to rectify and regulate the output voltage without affecting the resonance or insulation provided, while minimizing the losses generated. A last part exhibit that with a suitable dissipation system and manufacturing process, it is possible to integrate the complete structure on silicon chips
APA, Harvard, Vancouver, ISO, and other styles
2

Sibué, Jean-Romain. "Conception de systèmes d'alimentation sans contact pour la traction ferroviaire." Thesis, Grenoble, 2011. http://www.theses.fr/2011GRENT074/document.

Full text
Abstract:
Les travaux présentés dans cette thèse portent sur la conception et le dimensionnement de composant magnétique dédié au transfert d'énergie sans contact pour des applications ferroviaires de type tramway. Cette famille de composant présente un comportement fortement inductif. Un convertisseur à double fréquence de résonance est utilisé pour l'alimenter et compenser l'énergie réactive du coupleur. Pour parvenir à dimensionner ce composant et son convertisseur associé, un outil d'aide au dimensionnement a été mis au point. Celui-ci est basé sur des modèles analytiques du composant magnétique et de la structure d'électronique de puissance. Une fois le dimensionnement réalisé, une étude des pertes, dans les bobinages et les circuits magnétiques, est réalisée par simulation numérique en utilisant la méthode d'homogénéisation (représentation macroscopique des éléments avec des propriétés électromagnétiques complexes). Puis, la modélisation du comportement thermique du système est présentée afin de garantir la température de fonctionnement désirée. Afin de valider l'approche de dimensionnement et les outils mis en place, des expérimentations ont été menées sur des prototypes de 1,6 et 100 kW. Les résultats obtenus ont montré la précision et la pertinence de l'approche théorique. Cette étude valide la faisabilité de ce type de système forte puissance
The works presented in this thesis deal with the design and the sizing of magnetic component dedicated to contactless energy transfer for railway application like tramway. This family of component presents a strongly inductive behavior. A double resonance converter is used to supply and compensate reactive energy of transformer. In order to design this component and its associated converter, a design tool has been implemented. This one is based on analytical models of magnetic component and power electronic converter. One time designing realized, a study of losses, in windings and in magnetic cores, is realized by numerical simulation by using homogenization method (macroscopic representation of elements with electromagnetic complex properties). Then, the establishment of a model of thermal behavior of system is presented in order to guarantee desired working temperature. In order to check designing approach and tools, experimentations have been performed on prototypes of 1.6 and 100 kW. Obtained results show the accuracy and relevance of theoretical approach. Moreover, this study confirms the feasibility of this kind of high power system
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography