To see the other types of publications on this topic, follow the link: Transformatorer.

Dissertations / Theses on the topic 'Transformatorer'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Transformatorer.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Danielsson, Jonny. "Reläskydd för transformatorer : Funktioneroch Skyddsfilosofier." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-90323.

Full text
Abstract:
Skyddsfilosofierna gällande reläskyddsinställningar har varit densamma genom åren. En god avvägning mellan tillförlitlighet, selektivitet, enkelhet, hastighet och ekonomi krävs. Hur det görs är ofta ganska individuellt och skyddsfilosofier kan skilja en del mellan olika ingenjörer och därför finns inget exakt svar på hur den optimala lösningen för ett specifikt reläskyddssystem ska se ut.   Närmare undersökningar på funktioner och jämförelser har gjorts mellan det elektromekaniska överströmsskyddet RRMJ 4 och det nya numeriska skyddet            ABB REF 615. De båda differentialskydden, det statiska RYDSA 20 och det numeriska SPAD 346 har också undersökts och jämförts. Arbetet har visat att de elektromekaniska och statiska reläskydden var enkla i sitt utförande och pålitliga. De äldre skydd som testades fungerade fortfarande bra efter  30-40 år i drift.    Som väntat så var REF 615 betydligt snabbare än dess äldre motsvarighet RRMJ 4. Det som var mindre väntat var att det statiska differentialskyddet RYDSA 20 var ca 10 ms snabbare än det det numeriska skyddet SPAD 346. Kompabilititetsproblem av program till enheten upptäcktes vid inställningen av REF 615.     Slutsatsen blev att snabbhet och tillförlitlighet har förbättrats med de numeriska skydden, fler funktioner finns också inbyggda i samma burk. Men med mer funktioner blir de mer komplexa också och kräver mer av den person, som ska göra alla inställningar. Rätt inställda så har de numeriska skydden inneburit ett stort steg framåt. De äldre skydden var enkla, vilket är en stor fördel, men uppväger inte de fördelar de nya numeriska skydden har inneburit.
Protection philosophies have been the same throughout the years. A good balance between reliability, selectivity, simplicity, speed and economy are required. How it is done is often quite individually and protection philosophies may differ somewhat between different engineers, and therefore there is no exact answer to how the optimal solution for a specific relay protection system should look like.   More detailed studies on the features and comparisons have been made between the electromechanical overcurrent protection RRMJ 4 and the new numerical protection ABB REF 615. Both differential protections, the static RYDSA 20 and the numerical SPAD 346 has also been investigated and compared. The work has shown that the electromechanical and static relays guards were simple in its execution and trustworthy. The elderly protection tested still worked fine after 30-40 years of operation.   As expected, it was the REF 615 that was significantly faster than its older counterpart RRMJ 4. What was less expected was that the static differential protection RYDSA 20 was about 10 ms faster than the numerical protection SPAD 346.   The conclusion was that the speed and reliability have been improved with the numerical protections and more features are also built in. But with more features, they become more complex and also require more of the person who will make all the settings. Set correctly so has the numerical protections meant a great step forward. The older systems were simple, which is a big advantage, but do not outweigh the benefits of what the new numerical protections have meant.
APA, Harvard, Vancouver, ISO, and other styles
2

Gustafsson, Henrik. "Jämförelse mellan Hexatransformator och konventionella transformatorer." Thesis, University West, Department of Technology, 2002. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-404.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Assarsson, Fredrik, and Felix Nilsson. "Utredning av övertoners effekter på transformatorer." Thesis, Högskolan i Halmstad, Akademin för informationsteknologi, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-39706.

Full text
Abstract:
Detta examensarbete är en utredning om hur en av Halmstad Energi och Miljö Nät ABs transformatorer påverkas av övertoner. Utredningen handlar till största del om hur mycket transformatorns nominella effekt måste skrivas ner. Examensarbetet visar teorin kring både vad som är övertoner, övertoners effekter på transformatorer samt beräkningsmodeller för effektnedskrivning. De metoder som används och jämförs för nedskrivning av transformatoreffekt är faktor K, som beskrivs i SS-EN 50464-3 och K-faktor, som beskrivs i ANSI/IEEE C57.100. För att på ett verklighetstroget och ingenjörsmässigt sätt beräkna hur de olika standarderna påverkar transformatorn har tre fall testats.   Övertonernas medelinverkan under en månad, utifrån insamlade mätdata. Övertonernas maximala inverkan under en månad, utifrån insamlade mätdata. Övertonernas inverkan om övertonshalterna ökar i framtiden. Resultatet av utredningen visar att transformatorns nominella effekt i fallen där mätdata behandlas bör minskas med ca 6–17% för K-faktor-metoden. För faktor K är de siffrorna ca 2,5–7,5%. Dock visar mätdata från samtliga fallen att belastningsgraden på den testade trans-formatorn är långt under den maximala nedskrivna effekten. Om mängden strömövertoner i framtiden skulle öka är en nedskrivning på 30% av maxeffekten inte orimligt.
This thesis is a study of how one of Halmstad Energi och Miljö Nät AB’s transformers is affected by current harmonics. The study is mostly about how much the transformer's nominal power must be derated. The study shows the theory of both what is harmonics, how harmonics affect transformers and calculation models for derating transformers. The methods used and compared for the transformer power write-down are factor K, which is described in SS-EN 50464-3 and K-factor, which is described in ANSI / IEEE C57.100. In order to realistically investigate how the different standards affect the transformer, three cases have been tested. The mean effect of the harmonics over a month, based on collected measurement data. The maximum effect of the harmonics over a month, based on collected measurement data. The effects of harmonics if the harmonic levels increase in the future. The result of the study shows that in the cases based on measurement data the nominal power of the transformer should be reduced by about 6-17% for the K-factor method. For factor K, the figures are about 2.5-7.5%. However, the measurement data from all cases shows that the load rate of the tested transformer is far below the maximum impaired effect. If the amount of current harmonics would increase in the future, a write-down of 30% of the maximum effect is not unreasonable.
APA, Harvard, Vancouver, ISO, and other styles
4

Enbom, Nils, and Faruk Kodzaga. "Omkonstruktion av lyftögla till ABB:s transformatorer." Thesis, Uppsala universitet, Industriell teknik, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-414647.

Full text
Abstract:
Being able to supply larger parts of the world with renewable energy and satisfy the increasing energy demand requires larger and more efficient power transformers. Larger transformers are causing problems within the transport area since most of the railway in Sweden has a maximal width that must not be exceeded. In order to lift up to 600 tons and at the same time stay within the load profile, requires innovative solutions to the lifting lugs that are being used to lift the transformers. The aim with this study is to design a lifting lug that will be used to lift ABB: s transformers. Several requirements and wishes were first established for the new design of the lifting lug. These were then used to generate concepts. Pugh´s matrix was used to compare the concepts to each other as well as the current lifting lug. The concepts with the highest points were chosen for further development. The chosen concepts were then constructed together with a representation of the transformer in CAD which were used for FEM simulations in Creo. In the end one concept was chosen for further development. Continuous FEM analyses were performed during the study to ensure that the right design and the right dimensions were used to develop the best possible concept at the end. The best selected concept met all the requirements and most of the wishes for the lifting lug. In addition, the final dimensions were optimized to meet the weight classes 30-, 40-, 70-, 100- and 150 tons represented in two different tables in the result section of the study. Unfortunately, a
För att kunna förse större delar av världen med förnybar energi och tillfredsställa det ökande energibehovet krävs större och bättre transformatorer. Större transformatorer leder till problem med transport då många av järnvägarna i Sverige har en maximal bredd som inte får överstigas. För att kunna lyfta upp emot 600 ton och samtidigt hålla sig inom lastprofilen behövs innovativa lösningar på lyftöglorna som används för att lyfta transformatorerna.   Syftet med denna studie är skapa ett koncept för en lyftögla som kan använda både syntetiska- och stålvajrar för att lyfta ABB:s transformatorer. Först fastställdes ett antal krav och önskemål för designen av lyftöglan. Dessa användes sedan vid konceptgenereringen. Med hjälp av Pughs matris jämfördes koncepten med varandra samt med den nuvarande lyftöglan som valdes som referens. De koncepten som hade högst poäng valdes för vidareutveckling. Koncepten konstruerades i CAD tillsammans med en representation av transformatorn som användes vid simuleringar i Creo. Slutligen valdes ett koncept för att vidareutvecklas. För att konceptet skulle klara alla krav som ställts utfördes rullande FEM analyser under studiens gång för att kunna testa olika dimensioner och designer av konceptet för att komma fram till ett så bra koncept som möjligt.   Resultatet av studien blev att det slutvalda konceptet uppfyllde alla ställda krav samt de flesta önskemålen. Konceptets slutgiltiga dimensioner optimerades dessutom för att klara viktklasserna 30-, 40-, 70-, 100- och 150 ton som redovisas med hjälp av två tabeller i studiens resultatavsnitt. På grund av tidsbrist i studien kunde inte en prototyp av konceptet tillverkas.
APA, Harvard, Vancouver, ISO, and other styles
5

Gustafsson, Stig. "Driftoptimering av effektkondensatorbatterier och transformatorer på mottagningsstationer." Thesis, Högskolan Väst, Institutionen för ingenjörsvetenskap, 2010. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-2543.

Full text
Abstract:
Denna rapport innehåller en utredning av effektflöden på Uddevalla Energi Elnät AB:s mottagningsstationer och optimering av driftläggning för dess effektkondensatorbatterier och transformatorer. Uddevalla Energi Elnät AB har sedan 30 år haft effektkondensatorbatterier inkopplade nästan hela året och dessa behöver av åldersskäl snart bytas ut. Uddevalla Energi Elnät AB har därför behov av nya rutiner för driftläggning av effektkondensatorbatterier efter det att Svenska Kraftnät och Vattenfall AB har infört nya regler för de reaktiva effektflödena i elnätet. I utredningen om effektkondensatorbatterier har det gjorts en investeringskalkyl med tre alternativ för inköp. Alternativ 1 med central faskompensering på mottagningsstation, alternativ 2 med faskompensering på mottagningsstation kompletterat med faskompensering på abonnentstationer och alternativ 3 med lokal faskompensering på abonnentstationer.  Det framkom i utredningen att alternativ 2: Central faskompensering kompletterat med faskompensering på abonnentstationer är mest lämplig att genomföra.   Det har tidigare konstaterats att det under delar av året har varit låg belastning på några av mottagningsstationernas transformatorer. Det har aldrig utretts om det är lönsamt att stänga av den ena transformatorn under hela eller delar av året. I utredningen om driftläggning av transformatorerna på mottagningsstationerna har det beaktats tre alternativ. Ett alternativ innebär att en transformator körs i tomgång utan last och ett alternativ med en helt avstängd transformator. Det tredje alternativet är att inte göra någon förändring. I utredningen framkom det att det mest lämpliga är att inte göra någon förändring eftersom riskerna med avstängning är större än den ekonomiska vinsten på c:a 101000 SEK.
This report contains a study of power flows in Uddevalla Energi AB receiving stations and optimization of the operation control of its power capacitor batteries and transformers. For the past thirty years, Uddevalla Energi AB has employed power capacitor batteries almost all year around and these need soon to be replaced due to ageing. Uddevalla Energi Elnät AB has a need for new procedures for the operation control of the power capacitor batteries following new regulations introduced by Svenska Kraftnät and Vattenfall AB for reactive power flows on the grid. In the study of power capacitor batteries, there has been an investment calculation with three alternative purchase options. Option one is central phase compensation at the receiving station, option two is phase compensation at the receiving station supplemented with phase compensation at subscriber stations and option three is a local phase compensation at subscriber stations. The investment calculation shows that the second option: Central phase compensation supplemented with phase compensation at subscriber stations is the most favourable to implement. It has previously been found that, during certain times of the year, there has been a low load on some of the transformers of the receiving stations. It has never been investigated if it is profitable to turn off one of the transformer for the entire, or part of the year. In the investigation of the operation control of the transformers at the receiving stations, three alternatives have been considered. One alternative is that one transformer is in idle operation without load, the second alternative is that one transformer is completely turned off. The third alternative is to make no change. The study showed that the preferred alternative is to make no change, because the risks of turning off transformers are greater than the economic gain, that is approximately 101000 SEK.
APA, Harvard, Vancouver, ISO, and other styles
6

Gerlitz, Cecilia. "Empirisk studie av nollföljdsimpedansen hos transformatorer utan deltalindning." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-234904.

Full text
Abstract:
För att på ett noggrannt sätt kunna beräkna felströmmar är det viktigt att ha kännedom om plus-, minus- och nollföljdsimpedansen hos alla komponenter i elnätet. Transformatorer är en nyckelkomponent i elnätet och är därför inget undantag. Att analytiskt bestämma nollföljdsimpedansen är ofta svårt och därför utförs en rad tester vid tillverkningen av transformatorer för att bestämma denna storhet. Dessvärre saknar Svk, Svenska kraftnät, information om nollföljdsimpedansen för en del transformatorer och för att kunna göra tillförlitliga nätberäkningar måste nollföljdsimpedansen istället approximeras. Med säkrare modellering kan felströmmar beräknas med högre noggrannhet, vilket har bäring på både drift- och personsäkerhet.‌ Detta arbete presenterar en algoritm för att estimera nollföljdsimpedansen för en typ av transformatorer, trebenta kärntransformatorer som saknar L}-lindning. Algoritmen bygger på resultatet från en fallstudie, där lättillgänglig data för en population av transformatorer med känd nollföljdsimpedans, har analyserats. Fokus för analysen har varit på att identifiera samband mellan nollföljdsimpedansen och följande parametrar; märkeffekt, märkspänning, antal lindningar, tillverkare, tillverkningsår, tomgångsförluster, tomgångsström och slutligen kopplingstyp. Dessa parametrar har efter en inledande litteraturstudie om transformatorers konstruktion och teori identifierats som storheter som kan påverka nollföljdsimpedansen. Algoritmens inledning bygger på en kategorisering av transformatorerna efter kopplingstyp och antal lind- ningar och därefter en sortering efter märkeffekt. I nästa steg approximeras ett linjärt samband mellan nollföljdsimpedansen och tomgångsimpedansen, definierad som inversen av tomgångströmmen. Minsta kvadrat- metoden används för framtagning av linjära samband, vilka har förbättrats genom tillämpning av Bisquare- metoden. Tillförlitligheten i den presenterade algoritmen diskuteras med flera olika utgångspunkter, bland annat data- kvalitet och antal transformatorer i de analyserade kategorierna. För att få en så tillförlitlig och välgrundad modell som möjligt har extra tyngd i analysen lagts på de större transformatorgrupperna (fullindade YY- kopplade transformatorer med två lindningar och motsvarande autokopplade samt fullindade YY-kopplade med tre lindningar). Kvalitén på den analyserade datan undersöktes genom att försöka hitta avvikande vär- den. Resultatet visade att transformatorer med avvikande värden var väldigt sällsynta och att kvalitén på datan var god. Resultatet från fallstudien visar att tomgångsimpedansen för de vanligt förekommande transformatortyperna (YNyn0, YNauto0 samt YNyn0yn0) kan användas för att estimera nollföljdsimpedansen. Vid jämförelse av de framtagna modellerna framgår det att det existerar skillnader mellan transformatorer med hög respektive låg märkeffekt. Dessutom visar det sig att det existerar ett samband mellan lindningarnas nollföljdsimpedans och deras märkspänningar. Approximationen av en lindnings nollföljdsimpedans baserat på information om en annan lindnings spänning och nollföljdsimpedans kan göras med stor noggrannhet medan resultatet från fallstudien visar att osäkerheten i de övriga modeller är relativt stor.
In order to accurate calculate currents during unsymmetrical faults in the electric power grid information about all components positive, negative and zero sequence impedances are important. Transformers are one key component in the power grid and accurate information about sequence impedances for power transformers are therefore essential. However, to analytically derive the zero sequence impedance is extremely hard. Therefore are the transformers tested before they are connected.‌ The Swedish TSO (Transmission System Operator), Svenska kraftnät,Svk, are responsible for operating and balancing the Swedish transmission grid. For Svk it is crucial that the grid is operated in a reliable and safe way so that the society always have available electricity at the same time as no persons working on the grid are exposed to unnecessary risks. Having accurate current calculations during unsymmetrical faults is one crucial part. Unfortunate, for some transformers in Svk area of responsibility the information about zero sequence impedance is missing and must therefore be estimated. This work propose, by applying a case study on a existing group of transformers (three limb design with no L}. windings), a method for estimating the zero sequence impedance. The aim of the the analysis is to investigate if there are any relationship between the zero sequence impedance and some more basic operating data for the transformers. From an initial literature study it was concluded that the following parameters would affect the zero sequence impedance: rated power and voltage, no-load power and currents and information about winding configuration, manufacture and production year. In the case study linear relationships was found based on a least square method and was tuned using a robust linear square method called Bisquare. The results showed that several of the tested quantities showed a growing trend when they were correlated with the zero sequence impedance. The no-load impedance was identified as one interesting quantity that was investigated further. The tested transformers were divided into different groups based on number of windings and winding confi- guration. In the next step the transformers were ordered based on rated power. New linear relationships were derived for every group and the final results were compared between the different transformer groups. The reliability of the proposed algorithm is dependent on the size of the tested transformer group and also on the data quality. The data quality was investigated by trying to identify transformer with abnormal values. The results showed that abnormal behaviour was very rare in the tested group of transformers. The results from the case study indicates that a relationship between the no-load impedance and the zero sequence impedance exists for the common types of transformers, the YNyn0, YNauto0 and YNyn0yn0. The results shows that these relationships differ depending on the rated power of the high voltage winding. The case study also concludes that it is possible to estimate a winding’s zero sequence impedance if the zero sequence impedance for a second winding is known as well as the rated voltage of the two windings. The presented relationships have all some uncertainty related to them, for some relationships the uncertainty is relatively high whereas for others it is very low. The relationship with the lowest uncertainty found was the function describing a winding’s zero sequence impedance as a function of another windings zero sequence impedance and the rated voltages
APA, Harvard, Vancouver, ISO, and other styles
7

Weidemann, Stephan. "Handlingsplan för ägare av transformatorer med korrosiv olja." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-122436.

Full text
Abstract:
Sedan början av 2000-talet har ett stort antal transformatorer havererat av en initialt, okänd anledning. Problemet visade sig vara att en antioxidationstillsats i oljan, dibensyl disulfid (DBDS), reagerat med kopparen i lindningarna och vilket gett upphov till avlagringar på isolationspapperet i form av kopparsulfid. Kopparsulfiden i sin tur försvagade papperets isolationsförmåga och allvarliga driftstörningar eller driftstopp på grund av kortslutningar kan ske. Ett stort antal studier har genomförts för att ge klarhet i vad som händer, varför det händer och vad man kan göra åt problemet. Bakgrunden till detta examensarbete är att en 230MVA transformator har, trots att ägaren vidtagit rekommenderade försiktighetsåtgärder, havererat. Denna studie visar att ett flertal faktorer, såsom värme, svavelhalt och dåliga skarvar i lindningarna, påskyndar korrosionen av koppar och bildandet av kopparsulfid. Riskerna för haveri kan minskas genom att tillsätta Irgamet 39 i ett tidigt skede eller genom att byta/avsvavla oljan om transformatorn är äldre. Den redan bildade kopparsulfiden går däremot inte att avlägsna, så ett viktigt första steg är att stärka det elektriska skyddet genom att se över avledarna på transformatorn
Since the early 2000 a great number of transformers have broken down, without any apparent reason at first. The problem was identified to be an anti-oxidization-additive in the oil, dibenzyl disufide (DBDS), that had reacted with the copper in the windings. This gave rise to copper sulfide deposits on the isolating paper, which in turn reduced the isolating properties of the paper. A large number of studies have been completed to clarify what’s happening, why it’s happening and what can be done about it. The background for this thesis is that a 230MVA transformer broke down, despite the fact that the owner had taken the recommended precautions. This study will show that a number of factors, such as heat, Sulphur content and bad joints in the windings can accelerated the corrosion of copper and the formation of copper sulfide. The risks of a break-down can be reduced by adding Irgamet 39 at an early stage or by an oil change/desulphurization if the transformer is older. The already formed copper sulfide, on the other hand, cannot be removed and so an important first step is to fortify the electrical protection of the transformer by looking over the surge-arresters.
APA, Harvard, Vancouver, ISO, and other styles
8

Al-Breihi, Mohammed. "Utveckling av laboration om trefastransformatorn : En studie om transformatorer." Thesis, KTH, Skolan för teknik och hälsa (STH), 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-166240.

Full text
Abstract:
Examensarbetet har utforts pa uppdrag av enheten for Data- och Elektroteknik pa skolan for Teknik och Halsa, KTH. Denna studie om transformatorer omfattar deras funktioner och anvandningsomraden, hur de ar uppbyggda, hur karnan och lindningarna som ar transformatorns viktigaste delar ar uppbyggda, vilka materiel som anvands vid konstruktion av dessa samt vilka typer det finns av dem beskrivs i rapporten. Vidare beskrivs flera olika transformatortypers funktioner och anvandningsomraden. Eftersom en viktig del av studien varit pa vilka satt transformatorer kan utvecklas for okad miljovanlighet och livslangd gar rapporten igenom olika vegetabiliska oljor, vilka fordelar de har gentemot mineraloljor och vilka egenskaper de har samt pa vilket satt de ar skonsammare mot miljon. HVDC-enheter transformerar hoga spanningar fran vaxelspanning till likspanning for mindre resistiva forluster och darmed lagre energiforluster vilket i sin tur leder till en renare miljo. Teorigenomgangen av transformatorn ligger till grund for utformningen av en laboration for undervisningsbruk, bl.a. i en kurs om elkraftteknik som ges i hogskoleingenjorsprogrammet Elektroteknik pa KTH.
This degree project was carried out on behalf of the unit for Computer and Electrical engineering at the School of Technology and Health, KTH. This study about transformers, their function and uses, the way they’re built, how the core and windings, which are the most important parts of a transformer, are made and what kind of materials are used to make them. Several types of transformers and their functions are described. A crucial part of the study has been to search for different ways to develop transformers to make them environmentally safer and to increase their life-span. As such this work describes different transformer oils, what advantages and disadvantages they have compared to mineral oils, what properties they have and in what way they’re less harmful for the environment. HVDC units transform high voltages from Alternating Current to Direct Current to lessen the resistive losses and energy losses which lead to a cleaner environment. The theory examination of the transformer is the basis for the formation of a lab for educational use, among others in a course about electrical power that’s included in Bachelor of Science in Electrical Engineering at KTH.
APA, Harvard, Vancouver, ISO, and other styles
9

Dahlin, Carmen. "Empirisk bestämning av nollföljdsimpedans hos transformatorer med utdragen deltalindning." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-278507.

Full text
Abstract:
The main goal of the thesis is through available data, empirically determine the ratio betweenthe zero and positive-sequence impedance of different transformers with accessible-winding, i.e. when the -winding is loaded. Reasons for using a -winding couldfor example be to generate a specific phase shift in the voltage between the primary andsecondary side, or because it is economical at high current and low voltage. The thesisalso include an analysis on dependencies to tap-position, transformer construction andconnection type (auto connected or fully wound), as well as if variations can be related tomanufacture, type denotation, production year, rated power and rated voltage.Information of the ratio between the zero- and positive-sequence impedance are used tocalculate, for example, fault currents and are important when setting the protection system.A transformer’s sequence impedance is usually determined at the end of productionthrough a number of tests. However, there are several transformers in the power systemwithout information of the zero-sequence impedance and thus, this thesis has been performedsince necessary tests cannot be performed when the transformer is in operation.The data has been divided into six groups: shunt reactors, two-winding transformers witha -winding, three-winding transformers with one -winding, three-winding transformerswith two -windings, two-winding transformers with shorted Y-winding and withouta -winding and three-winding transformers with shorted Y-winding and without a -winding.To analyse the available data, an algorithm has been created in MATLAB to find possiblecorrelations. Relations has been linear modelled and are presented visually and numericallywith prediction intervals to be used in future network calculations. The mean andthe confidence interval of the ratio between the zero- and positive-sequence impedance,as well as the ratio between the zero- and positive-sequence resistance has been calculatedfor each group, depending on the number of core legs of the transformer.The most important results include the mean (and the confidence interval) for the ratiobetween the zero- and positive-sequence impedance, as well as the ratio between the zeroandpositive-sequence resistance for transformers with three and five legs. A correlationwas found for the ratio between the zero- and positive-sequence impedance and the tapposition.Furthermore, it was found that the ratio between the zero- and positive-sequenceimpedance has had an upgoing trend over the years, while the ratio between the zero- andpositive-sequence resistance has had a downwards trend. This is especially true for twowindingtransformers with an -winding. Following, a correlation was found betweenthe zero-sequence resistance and the positive-sequence impedance, where the data pointswere divided into two groups, where one of them was gathered around transformers withfive-leg core. A possible explanation could be that these transformers are equipped withmagnetic shunts. However, this was not possible to investigate in this study.
Huvudändamålet med avhandlingen är att genom tillgänglig data, empiriskt bestämmakvoten mellan noll- och plusföljdsimpedansen hos olika transformatortyper med utdragen-lindning, d.v.s. när -lindning är belastad. Anledningar till att använda en -lindningkan t.ex. var för att tillgodose en specifik fasförskjutning i spänningen mellan primär- ochsekundärsidan, eller för att det är ekonomiskt vid hög ström och låg spänning. Avhandlingenbehandlar även beroende av lindningskopplarläge, transformatorkonstruktion ochkopplingsart (autokopplat och fullindat) och undersöker om variationer går att relatera tillfabrikat, typbeteckning, tillverkningsår, märkeffekt och märkspänning.Information om kvoten mellan noll- och plusföljdsimpedansen används för att t.ex. beräknafelströmmar, vilket är viktigt för att ställa in skyddssystem. En transformators sekvensimpedanserbestäms vanligen efter tillverkningen genom ett antal tester. Dock saknar ett antaltransformatorer i elnätet data om nollföljdsimpedansen och det är p.g.a. detta som den häravhandlingen genomförts, då nödvändiga prov inte kan genomföras när transformatorn äri drift.Datan har delats in i sex grupper: shuntreaktorer, tvålindningstransformatorer med en-lindning, trelindningstransformatorer med en -lindning, trelindningstransformatorermed två-lindningar, tvålindningstransformatorer med kortsluten Y-lindning och utan-lindning och trelindningstransformatorer med kortsluten Y-lindning och utan -lindning.För att analysera den tillgängliga datan har en algoritm skapats i MATLAB för att finnamöjliga korrelationer. Samband har modellerats linjärt och presenterats visuellt och numerisktmed tillhörande prediktionsintervall för att kunna användas i framtida nätberäkningar.Medelvärdet och konfidensintervallet av kvoten mellan noll- och plusföljdsimpedansen,samt kvoten mellan noll- och plusföljdsresistansen har beräknats för varje grupp, beroendepå det antalet kärnben transformatorn har.De viktigaste resultaten inkluderar medelvärdet (och konfidensintervallet) för kvoten mellannoll- och plusföljdsimpedansen, samt för kvoten mellan noll- och plusföljdsresistansenför fem- och trebenta transformatorer. Vidare upptäcktes korrelationer för kvoten mellannoll- och plusföljdsimpedansen och lindningskopplarläget. Dessutom observerades attkvoten mellan noll- och plusföljdsresistansen har stigit med tiden, medan kvoten mellannoll- och plusföljdsresistansen har avtagit. Detta gäller framförallt tvålindningstransformatorermed en -lindning. Dessutom upptäcktes en korrelation mellan nollföljdsresistansenoch plusföljdsimpedansen där datapunkterna delat upp sig i två grupper, där den enagruppen samlats runt fembenta transformatorer. En möjlig förklaring är att dessa transformatorerkan vara utrustade med magnetiska shuntar, men detta gick inte att undersökavidare i denna studie.
APA, Harvard, Vancouver, ISO, and other styles
10

Almqvist, Gunilla. "Lathund för val av förband mellan transformator och ställverk." Thesis, University West, Department of Technology, 2002. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-352.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Golmohammadi, Behnam. "Användning av programvaran Templife för analys av överbelastbarheten hos ett urval av Vattenfall Västnäts krafttransformatorer." Thesis, University West, Department of Technology, Mathematics and Computer Science, 2004. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-405.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Varg, Torun, and Erica Oberholtzer. "Brandrisker och skyddshöjande brandtekniska åtgärder för kabelutrymmen, lokaler för växelhuvudströmscentral och transformatorer inom vattenkraftverk." Thesis, Luleå tekniska universitet, Byggkonstruktion och brand, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-77241.

Full text
Abstract:
Dagens samhälle är beroende av el, allt från att få rent vatten i kranen till att kunna tanka bilen kräver el. Vattenkraftverk står för nästan 50% av dagens elproduktion i Sverige vilket medför att vattenkraft är en väsentlig verksamhet för att få samhället att fungera. Ur ett miljöperspektiv anses vattenkraft vara mer miljövänlig än el som produceras på fossila bränslen. I och med den stora rollen vattenkraft spelar i dagens samhälle är det viktigt att förebygga eventuella olyckor och produktionsstopp, till exempel bränder. Bränder har tidigare förekommit på vattenkraftverk runt om i världen. Colorado är ett exempel där det började brinna i det brandfarliga materialet som arbetades med i en tunnel på stationen. Detta resulterade i en brand där flera arbetare blev instängda i en tunnel under marken, samtliga omkom då det endast fanns en utrymningsväg. I vattenkraftstationer som är belägna under marken är det vanligt förekommande att det endast finns en utrymningsväg. Olyckan påvisar den komplexitet som finns vid dimensionering av vattenkraftstationer under marken. Syftet och målet med detta projekt har varit att identifiera brandrisker på två vattenkraftverk och finna passande åtgärder för att minimera och förebygga dessa. För att uppnå projektets mål har bland annat en litteraturstudie genomförts för att ge en förståelse över problem som kan uppstå. En riskidentifiering genom platsbesök har också genomförts för att se hur det ser ut i verkligheten på de två vattenkraftstationerna. Det har även gjorts en datasimulering för att ge en uppfattning av rökspridningen, denna datasimulering har genomförts med hjälp av Fire Dynamics Simulator (FDS). Litteraturstudien påvisade, genom statistik från MSB:s databas IDA, att transformatorbränder är en av de största riskerna i anläggningar under marken. Vid platsbesöket på Messaure, ett vattenkraftverk, fanns det endast lokaltransformatorer placerade under marken. Dessa lokaltransformatorer var av typen torrtransformator vilket medför en mindre brandrisk. Tidigare fanns även övriga transformatorer under mark men dessa är flyttade ovan mark för att minimera brandrisken. Till skillnad från Messaure fanns Akkats, ett vattenkraftverk, transformator placerad under mark i en egen transformatorhall vilket utgör en egen brandcell. Entrén till denna fanns i direkt anslutning till tillfartstunneln som också används för utrymning. För att undersöka hur mycket en brand i transformatorhallen skulle påverka utrymningen valdes detta utrymme för en FDS-analys. Den slutsatsen som kan dras är att skulle dörren stå öppen skulle en brand i transformatorn ha en stor negativ inverkan på utrymningen. Rökutvecklingen skedde snabbt och röken strömmade tidigt ut i tillfartstunneln vilket medförde en påverkan på all utrymning. Vanligtvis ska dörren till transformatorhallen vara stängd men den kan lätt glömmas öppen i och med att det inte finns en dörrstängare. En kostnadseffektiv förbättring vore att installera en dörrstängare, det skulle kunna rädda liv.
Today's society is dependent on electricity, from getting clean water in the faucet to being able to put fuel in the car electricity is required. Hydroelectric power plants account for almost half of today's production of electricity, which means that hydropower is a vital factor for the community to function. From an environmental perspective, hydropower is considered more environmentally friendly than electricity produced from fossil fuels. Since hydroelectric power plants play a big role in society makes it very important to prevent possible accidents and hold-ups in production, such as a fire. Fires have occurred at hydropower plants around the world. Colorado is an example where the fire started in the flammable material that was being used in a tunnel at the hydropower plant. This resulted in a fire where several workers were trapped in a tunnel underground, all workers died since there was only one escape route. In hydropower stations located underground, it is common that there is only one escape route. The accident demonstrates the complexity that exists in the dimensioning of hydropower stations underground. The purpose and goal of this project has been to identify fire risks at two hydropower plants and how to minimize and prevent them. In order to achieve the project's goals, a literature study has been conducted to provide an understanding for the problems that may arise. A risk investigation was also conducted at the hydropower plants to see what they look like in the reality. A computer simulation has also been made to give an idea of the smoke spread. This computer simulation has been performed using the Fire Dynamics Simulator (FDS). The literature study showed, through statistics from MSB's database IDA, that transformer fires are one of the biggest risks in underground facilities. During the visit to Messaure, a hydroelectric power plant, only the local transformers were placed below the ground. These local transformers were of a dry-transformer type, which results in a smaller fire hazard. Previously, there were also other transformers underground, but these are moved above ground to minimize the fire hazard. Unlike Messaure, Akkat's, a hydroelectric power plant, transformer was placed underground in a separate transformer hall, which is a separate fire cell. The entrance to this was directly adjacent to the access tunnel which is also used for evacuation. To investigate how much a fire in the transformer hall would affect the evacuation, this space was chosen for an FDS analysis. The conclusion that can be drawn is that if the door should be left open, a fire in the transformer would have a major negative impact on the evacuation. Smoke quickly streamed into the access tunnel, which has an effect on all evacuation. The door should always be closed . However, there is no automatic door closer, which can result in the door being left open. A cost-effective improvement would be to install a door closer, which could save lives.
APA, Harvard, Vancouver, ISO, and other styles
13

Bergdahl, Johan, and Andreas Karlsson. "Kraftvärmeverk 1 Egenförbrukning : En studie över frånkopplingsmöjligheter." Thesis, Linköping University, Department of Management and Engineering, 2007. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-10603.

Full text
Abstract:

Rapporten beskriver hur vi gått tillväga för att lösa uppgiften som var att bestämma om det går att stänga av några transformatorer under sommarrevisionerna när man inte producerar någon elektricitet. Den tar även upp hur förbrukad el förhåller sig till förbrukad effekt vid vissa driftfall, samt även hur förbrukningen ser ut kontra producerad över året.

Genom kartläggande av de stora effektförbrukarna, och bestämma under vilka driftfall de används, har vi kunnat konstatera att det skulle krävas ett mycket omfattande omkopplingsarbete för att kunna koppla ifrån en transformator. Vidare undersökte vi de faktiska tomgångskostnaderna för själva transformatorerna och kom fram till att dessa är väldigt små i sammanhanget.

Många problem uppenbarade sig under arbetets gång ju mer information som intogs, exempel på det är just att många komponenter till de olika pannorna är fördelade över flera transformatorer och en annan orsak är att centraler för lampor och dylikt är kopplade i olika omfattning till de olika transformatorerna, vilket gör att om man slog av dessa skulle de som jobbar under revisionerna få arbeta i mörker. Slutsatsen blir att det är svårt att hitta enkla sätt att spara energi, som att slå av och på en transformator, och att man kanske borde titta mer på enskilda komponenter.

APA, Harvard, Vancouver, ISO, and other styles
14

Härjebäck, Anders. "Avfallshantering : På Härjeåns Nät AB, med fokus på energi- och materialåtervinning." Thesis, Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-16073.

Full text
Abstract:
This thesis was conducted at Mälardalen University in Västerås and Härjeåns Nät AB, mainly in Sveg. Härjeåns Nät AB is a network company that delivers electricity in Härjedalen municipality, Ånge Municipality, Ragunda and Bräcke municipality. The maintenance and dismantling of electricity and broadband networks generates a lot of waste. The purpose of this work is to present proposals on the management of the waste. The goal is that all of Härjeåns offices should have equal management for the waste and an overview of how to manage the various wastes. This will be a step toward ISO certifications ISO 9001:2008 for quality and ISO 14001:2004 for environment. Companies are obliged to know the laws and regulations that apply to operate the business and the waste generated as a result. The alignment of the work lays on the management suggestions, which has led to a short description of today’s situation, with deeper information of all laws and regulations that affects Härjeåns waste. Today’s state at the office in Sveg is that much different waste is placed in the same container that give rise to high costs for the company. Impregnated poles lack good management and hazardous waste needs concrete guidelines to follow. Metals are sorted well but may need an overhaul. Signs exist but are old and faulty. Waste occurs with many different characteristics and handling varies depending on the type of waste, geographic location and how well it is sorted. Sorting the materials correctly reduces disposal costs and may instead generate a replacement, for example sorting iron and other metals and sell them. The laws that affects waste management is the Environmental Code, Waste Regulation, Environmental Protection Agency's Code of Statutes 2004:10 and local directives. Härjeåns are required to have the right knowledge of hazardous waste and how it affects health and the environment, rules for handling and classification, documentation, and prevention. All hazardous waste requires entrepreneurs that have a special permit to transport it from the County Council. Other waste should be transported in an environmentally sound manner using approved and conscious entrepreneurs. Management suggestions of the waste is presented, requirements for entrepreneurs and waste stations is proposed, which partitions that are necessary, which laws that must be followed and what solutions there are.
Detta examensarbete har utförts vid Mälardalens Högskola i Västerås och Härjeåns Nät AB, främst i Sveg. Härjeåns Nät AB är ett elnätsföretag som står för eldistributionen i bl.a. Härjedalens kommun, Ånge kommun, Ragunda kommun och Bräcke kommun. Vid underhåll och rasering av el- och bredbandsnät uppkommer en hel del avfall. Syftet med detta examensarbete är att lägga fram förslag på hantering av avfallet. Målet är att alla Härjeåns arbetsplatser ska ha likvärdig hantering av avfallet och en översikt om hur man ska hantera de olika avfallen. Arbetet ska bedrivas som ett steg mot ISO-certifieringarna SS-EN ISO 9001:2008 för kvalitet och SS-EN ISO 14001:2004 för miljö. Företag är skyldiga att känna till vilka lagar och regler som gäller för att bedriva verksamheten och avfallet som genereras som följd av denna. Tyngden i arbetet ligger på hanteringsförslag, vilket har lett till att nulägesbeskrivningen hållits kort med desto mer tid för informationssökning av alla lagar och förordningar som berör Härjeåns avfallshantering. Dagsläget på linjekontoret i Sveg innebär att mycket avfall läggs i en osorterad container som ger upphov till höga kostnader för företaget. Impregnerade stolpar saknar god hantering och farligt avfall behöver konkreta riktlinjer att följa. Metaller sorteras bra men kan behöva en översyn. Skyltning finns men är gammal och bristfällig. Avfall förekommer med många olika egenskaper och hanteringen varierar beroende på vilken typ av avfall det handlar om, geografiskt läge samt hur välsorterat det är. Att sortera material rätt minskar kostnader för omhändertagande och kan istället generera en ersättning, till exempel att sortera järn och metaller och sälja dessa. De styrmedel som främst berör avfallshantering är Miljöbalken, Avfallsförordningen, Naturvårdsverkets författningssamling 2004:10 och kommunala direktiv. Innehållet i dessa författningar granskas för material som uppkommer inom elnätsbranschen. Vid uppkomst av farligt avfall är företaget skyldigt att ha rätt kunskaper om avfallet och hur det påverkar hälsa och miljö, regler för hantering och klassning, dokumentering samt förebygga uppkomsten. Allt farligt avfall kräver en entreprenör som har särskilt tillstånd att transportera och/eller förvara det från Länsstyrelsen. Övrigt avfall bör transporteras och omhändertas på ett miljöriktigt sätt med godkända och medvetna entreprenörer. Förslag på hantering av avfallet läggs fram, krav på entreprenörer och mottagningsstationer föreslås, vilka partitioner som är nödvändiga, vilka lagar som måste följas och vilka helhetslösningar som finns.
APA, Harvard, Vancouver, ISO, and other styles
15

Nilsen, Ida. "Investerings- och byggnationsanalys av integrerade och fristående strömtransformatorer i Ellevios regionnät." Thesis, Högskolan Väst, Avdelningen för Industriell ekonomi, Elektro- och Maskinteknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-12388.

Full text
Abstract:
Syftet med detta examensarbete är att genomföra en teknisk- och ekonomisk undersökning av två byggnationssätt av strömtransformatorer i ställverk: fristående strömtransformatorer och strömtransformatorer inbyggda i krafttransformator. I krafttransformatorn, mättransformatorn, ström-, och spänningstransformatorn. Krafttransformatorn är en av de viktigaste komponenterna i elnätet, vars huvuduppgift är att transformera elektricitet från en spänningsnivå till en annan. Mättransformatorer används till att galvaniskt åtskilja högspänningskretsar från mätinstrument och anpassa spänningar och strömmar till lämpliga nivåer. Spänningstransformatorns uppgift är att transformera de primära spänningarna till sekundära mätspänningar medan strömtransformatorn huvuduppgift är att omvandla primära strömmar, till mindre, standardiserade, sekundära strömmar för att få mindre och mer hanterbara strömmar som är enklare att mäta. I examensarbetet jämförs för- och nackdelar med fristående och integrerade strömtransformatorer i Ellevios regionnät. Två kostnadskalkyler tas fram och en kravstudie om Ellevios gällande krav för mätning med mättransformatorer i regionnätet presenteras. Detta har skett genom omfattande kartläggning och intervjuer med sakkunniga intressenter inom området. Den teoretiska och ekonomiska undersökningen visar att investeringskostnaden för den integrerade strömtransformatorn är avsevärt lägre och att den är utrymmesbesparande samt att det är mer komplicerat att åtgärda eventuella fel på denna typ av strömtransformator.
The purpose of this diploma thesis is to conduct a technical and economic investigation of two construction methods of current transformers in substations. In the report the power transformer, the instrument transformer, the current and voltage transformers are presented. The power transformer is one of the most important components in the power grid, whose main task is to transform electricity from one voltage level to another. The instrument transformers are used to separate high voltage circuits from the measuring instruments. The voltage transformers task is to transform the primary voltages into secondary measurement voltages, and the current transformer main task is to convert primary currents to smaller, standardized secondary currents to get less and more manageable currents that are easier to measure. In the thesis, pros and cons with the independent and integrated current transformers are compared in Ellevio's regional network. Two financial calculations are presented and a requirement study about Ellevio's current requirements for measurement with instrument transformers in the regional network is submitted. This has been through extensive surveying and interviews with expert stakeholders in the area. The theoretical and economic investigation shows that the investment cost of the integrated current transformer is considerably lower and that it is space saving and that it´s more complicated to correct possible errors on this type of current transformer.
APA, Harvard, Vancouver, ISO, and other styles
16

Hellborg, Jonatan. "Analys av industrinät med spänning 7,8 kV." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-159776.

Full text
Abstract:
Bofors industrinät i Karlskoga är föråldrat och ligger kvar på en icke standardiserad spänning vilket är ett problem. Denna analys har utförts på uppdrag av Karlskoga energi och miljö AB med syfte att undersöka vad som behöver bytas ut, tillkomma eller tas bort för att höja från dagens spänning (7.8 kV) till samma standardiserade nivå som det resterande distributionsnätet (10 kV). Utöver detta även ta fram ett ramverk för hur spänningshöjningen skall gå till, samt undersöka hur stora förlustbesparingar företaget kan erhålla på grund av höjningen. Det visar sig att industrinätets samtliga 39 distributionstransformatorer måste bytas för att dessa inte skall haverera men att kablaget klarar sig då detta är konstruerat för 12 kV. Handlingsplanen som tagits fram utgår från att Karlskoga energi och miljö AB bygger ett nytt nät med spänningen 10 kV, och under en längre tid låter existerande kunder ansluta sig till detta. Gällande förlusterna i nätet visar det sig att det potentiellt finns stora besparingar att göra, cirka 415 708 kr om året vid ett elpris på 85 öre per kWh, där minskningen av tomgångsförlusterna kommer stå för majoriteten. De beräknade kabelförlusterna visar sig vara nästan obefintliga. Allt detta visar på nyttan med att genomföra spänningshöjningen och ombyggnationen som krävs för detta. Initialt är det för en avsevärd investering för företaget, men fördelarna är så pass stora att det vore oansvarigt att inte genomföra detta. Genom ombyggnationen får man ett bättre nät, inte bara bättre dimensionerat utan även driftsäkerhetsmässigt med kortare leveranstider för exempelvis transformatorer.         Undersökningen har inte gått in på de två vattenkraftanläggningarna som är anslutna till industrinätet, mer än i förbigående.
The Bofors industrial power grid in Karlskoga is aged and currently operating with a non-standardized voltage level. This analysis has been done in collaboration with “Karlskoga energi och miljö AB” with the purpose of determining what needs to be replaced, added or removed in order to facilitate an increase in voltage from today’s level (7.8 kV) to the same level as the rest of the distribution grid (10 kV). In addition to this also produce the framework for a plan on how this voltage increase is to be accomplished, as well a determining how much the losses can be reduced and how much of an economic impact this has. The results of the analysis are that all of the 39 distribution transformers currently in use must be replaced in order to not have these break down. The cables in use, however, will be fine due to them being constructed for 12 kV. The framework produced determines that the best course of action is for the company to build a new grid on top of the old one, with a voltage of 10 kV and allow existing customers to connect to this grid during a set time period. In regards of the losses in the grid, a potentially large saving can be made.  Approximately 415 708 SEK per year, calculated with an energy price of 0.85 SEK per kWh, of which the no-load losses of the transformers is the majority. The calculated cable losses were almost non-existing. All this proves the benefits of performing this voltage increase, and the construction required. Initially there is quite a large investment needed from the company, but the benefits are large enough that It would be irresponsible to not go through with the voltage increase. By doing this the company gets a better grid, not just better dimensioned but also a much more reliable grid with shorter delivery times on for example transformers. This analysis has not gone into depth regarding the two hydropower plants connected to the grid.
APA, Harvard, Vancouver, ISO, and other styles
17

Fältström, Mattias, and Berg Joakim Nelson. "Förstudie av fasningssystem : Till dieselgeneratorer på Forsmark 1." Thesis, Uppsala universitet, Elektricitetslära, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-297937.

Full text
Abstract:
Kärnkraft är en av flera energikällor i dagens samhälle men är i synnerhet den energikälla som ställer högst krav på säkerhet. På Forsmarks kärnkraftverk har alltid säkerheten varit av stor betydelse sedan uppstarten 1980, när Forsmark 1 togs i drift. Som följd av detta har det skapats ett flertal säkerhetsfunktioner, varav en av dessa är reservkraft i form av dieselgeneratorer. Dieselgeneratorerna utsätts med jämna mellanrum för verifieringsprov för att säkerhetsställa systemets funktion vid eventuell händelse och utgör en viktig del för ett robust system. Ett av verifieringsproven på dieselgeneratorerna är att de ska synkroniseras med det övriga systemet, vilket utförs av fasningssystemet. Problematik har uppstått vid tidigare synkroniseringstillfälle av en dieselgenerator, som uppkom på grund av yttre påverkan. Därför har det här examensarbetet utförts som en förstudie för Forsmarks Kraftgrupp AB i syfte att granska fasningsutrustningen och dess kringutrustning tillhörande dieselgeneratorerna på Forsmark 1. Det nuvarande systemet har undersökts för att se hur uppbyggnaden ser ut idag och för att redogöra för potentiella förbättringsmöjligheter. Examensarbetet har kartlagt nuvarande fasningssystem med tillhörande mätutrustning, genom att studera dokumentation, mätningar, kontakt med leverantörer, utförande av simuleringar samt test av mättransformatorer. Det är för att förstå fasningssystemets funktioner, lokalisera eventuella svagheter i systemet samt potentiella förbättringar och därmed öka tillförlitligheten till en säker synkronisering. Ett skäl till varför det är viktigt med ett fungerande fasningssystem är för att skydda generatorn och kringliggande system. Arbetet har gett en bra översikt över hur dagens fasningssystem och mätutrustning fungerar på Forsmark 1. Detta ger Forsmarks Kraftgrupp AB ett viktigt underlag för beslut av eventuell framtida ombyggnad av fasningssystemet eller omkonfiguration av enskilda delar om nuvarande fasningsutrusning bevaras. Rekommendation vid eventuell ombyggnation är att införa trefasmätning med kompatibel fasningsutrustning. Samt rekommenderas att trefasmätningen mäts separat istället för idag tillsammans med övrig utrustning. Om istället nuvarande fasningsutrustning bevaras och enskild del byts, rekommenderas att omkonfigurera mättransformatorerna till ∆-Y från Yn-Yn koppling. I det fall systemet byggs om eller omkonfigureras har rekommendationer för verifieringsprov av eventuella ändringar tagits fram.
It is well known that nuclear electricity production is one of the types of production with the highest demands on security. There are multiple security systems, and one consists of diesel generators. The diesel generators need a synchronization system to be able to confirm safe starting operation. This master thesis investigates the synchronization system and associated measuring systems to the diesel generators, with the purpose of advising Forsmarks Kraftgrupp AB on things that could be changed concerning transformer- and synchronization configuration at Forsmark 1. An improved solution to the existing synchronization system with its associated measurement equipment was found by studying documentation, performing measurements on the system, contacting suppliers, performing simulations and testing the instrument transformers. The results that emerged from the feasibility study have made suggestions for either possible reconstruction or reconfiguration of individual parts of the existing synchronization system. The recommendation in case of redevelopment is to introduce a three-phase measurment system compatible with the synchronization equipment with a separate three-phase measuring circuit. If instead, the existing synchronization equipment is preserved and an individual part replaced, it is recommended to reconfigure the instrument transformers to delta-Y from the present Yn-Yn connection. If the system will be rebuilt or reconfigured, recommendations for confirmatory testing of any modifications have been developed.
APA, Harvard, Vancouver, ISO, and other styles
18

Scheutz, Godin Axel. "Tillståndsbedömning av krafttransformatorer i stamnätet : En rekommendation av diagnostiska mättekniker." Thesis, KTH, Skolan för elektro- och systemteknik (EES), 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-187813.

Full text
Abstract:
Ett transformatorfel kan få stora ekonomiska konsekvenser och påverka ett elkraftsystems driftsäkerhet. Genom att övervaka en transformators tillstånd kan haverier och avbrott undvikas. Tillståndsövervakning möjliggör även att förebyggande underhåll kan planeras effektivt. Det här arbetet har undersökt tillgängliga diagnostikmetoder och övervakningstekniker för tillståndsbedömning av transformatorer.  Tillgänglig felstatistik för transformatorer har studerats ingående för att förstå vilka fel som kan uppstå i en transformator och i vilken grad de förekommer. Eftersom felen har olika konsekvenser för transformatorns fortsatta drift har dessa undersökts. Befintliga metoder för att upptäcka fel har dokumenterats. Detta har utförts genom att studera tillgänglig litteratur och via intervjuer med företag som tillverkar övervakningsutrustning för transformatorer. Övervakningsmetoderna har jämförts med avseende på kostnad, livslängd och noggrannhet. Utifrån dessa analyser har en rekommendation tagits fram över vilka övervakningsmetoder som är mest lämpade för Svenska Kraftnät. Det finns verktyg för att kvantifiera resultaten från övervakningsmetoder till lättolkad information. Ett sådant är hälsoindexet, som komprimerar data från olika mätningar, till ett enskilt värde som representerar en komponents tillstånd. En fallstudie har utförts där tre transformatorers tillstånd under perioden 2002–2015 har undersökts med ett befintligt hälsoindex. Resultatet visar att hälsoindex kan utnyttjas för att indikera transformatorernas tillstånd. Nackdelen med hälsoindexet som användes är att indexet är fortsatt högt oavsett kvaliteten på isolationsmaterialet. Därför föreslås en alternativ modell för en hälsoindexberäkning, i vilken pappersåldringen beaktas i större utsträckning.
A transformer fault could affect the reliability of a power system and have serious economic consequences. Therefore there is an increasing demand among electrical utilities to assess the actual condition of their transformers and hence detect faults before they occur. Condition monitoring has the potential to reduce operating costs and improve the reliability of operation. The aim of this master thesis has been to investigate available diagnostic measurement techniques that can assess the condition of power transformers. Transformer failure statistics has been studied in order to understand what different faults that can occur and to which extent they appear. The consequences of different faults have been investigated. Available measurement techniques were coupled with what faults they can detect. The diagnostic measurement techniques have also been compared in regard to cost, lifetime and accuracy. The comparison resulted in a recommendation over which measurement techniques that are most suitable for the Swedish transmission system operator, Svenska Kraftnät. There is a need among electrical utilities of economic and technical justifications for optimal investment and maintenance decisions. One available asset management technique that enables this is the health index. A health index is a tool that combines available measurement data from operating observations, field inspections and laboratory testing into an objective and quantitative index. The index provides information about the overall condition of an asset. A case study has been conducted where an available health index was used to estimate the condition of three transformers. The results indicate that the health index presents an efficient way to represent the condition of transformers. The disadvantage of the used index is that it implies a good condition even when the quality of the transformer insulation paper is poor. An alternative health index is therefore proposed where the paper insulation quality has a larger impact on the index.
APA, Harvard, Vancouver, ISO, and other styles
19

Goßner, Thomas. "Effizientes Design von Planar-Transformatoren." kostenfrei, 2010. https://mediatum2.ub.tum.de/node?id=823188.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Ataniyazov, Ataniyaz. "Transformatorers tekniska och ekonomiska livslängd." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-96594.

Full text
Abstract:
Detta examensarbete är utfört på WSP i Skellefteå på uppdrag av Rönnskärverket i Skelleftehamn. Rönnskärverkets började byggas av Boliden AB 1928 och var färdigt för produktion år 1930. Man producerar koppar, bly, zinkklinker, guld och silver. År 2010 producerade Rönnskär 190 000 ton koppar och år 2013 producerades 206 000 ton. Här jobbar 866 medarbetare i dagsläget. Elförbrukningen för verksamheterna inom NEW Bolidens uppgår till ca 1,2 TWh/år. Rönnskärs industriområdes elförsörjning är mycket högprioriterad och transformatorhaverier leder till långa stilleståndstider och dyra reparationer. Krafttransformatorerna måste ha hög drifttillgänglighet och transformatorerna som inhandlas till produktionsanläggningarna måste vara robusta. Syftet med detta examensarbete är att göra en jämförande studie mellan torrisolerade och oljeisolerade transformatorer som resulterar i en rekommendation med tanke på framtida inköp. Arbetet ska belysa parametrar för drifttillgänglighet och driftsäkerhet, göra beräkningar för korslutningsströmmar och förluster på transformatorer utifrån transformatortillverkarens uppgifter. Examensarbetets mål är att jämföra olika parametrar på torr- och oljeisolerade transformatorer från olika tillverkare som resulterar i en jämförelsetabell beroende på skenbar effekt och spänning, visar skillnaden mellan olika typer av transformatorer. I arbetet finns en litteraturstudie främst inom transformatorteori som underlag parallellt med en löpande dialog med uppdragsgivaren och transformatortillverkaren. Rekommendationerna ska ses som en förstudie. En djupare analys och ytterligare utredning krävs vid inköp av transformatorer, beroende på omständigheterna och driftsvillkoren. En ekonomisk analys har inte utförts på grund av den begränsade informationen. Nyckelord för examensarbetet är TD: Tillgänglighet, Driftsäkerhet.
This thesis is performed at WSP in Skellefteå, specializing in Rönnskär Education in Skelleftehamn. Rönnskär’s construction began by Boliden AB in 1928 and it was ready for production in 1930. It produces copper, lead, zinc clinker, gold and silver. In 2010 Rönnskär produced 190000 tons of copper and in 2013 it produced 206 000 tons. Current number of employees is 866. The electricity supply of the industrial area of Rönnskär is in very high priority and transformer failures leading to lengthy downtime and expensive repairs. Power transformers must have high operational availability transformers which purchases for production must be robust. This is a comparative study between dry type and oil insulated transformers which summarized in form of recommendation for the future purchases. The work will highlight the parameters of operational availability and operational safety make calculations for rated short time currents and losses in transformers based on manufacturers data. The aim of this thesis is to compare various parameters of dry and oil immersed transformers from different manufacturers summarized in a comparison table according to the apparent power and voltage which shows the difference between various types of transformers. This work is primarily based on the theory of transformers and at the same time on continuous dialogue with the client and the transformer manufacturer. The recommendations should be viewed as a preliminary study, a deeper analysis and further investigation is required when purchasing transformers, depending on the circumstances and the conditions. An economic analysis has not been performed because of the limited information. Keyword for this study is AOS: Availability and Operational Safety.
APA, Harvard, Vancouver, ISO, and other styles
21

Meinert, Michael. "Hochtemperatursupraleitende Transformatoren für künftige Schienenfahrzeuge /." Aachen : Shaker, 2007. http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&doc_number=016499393&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Blėdis, Tomas. "Sausų galios transformatorių panaudojimo tyrimas." Master's thesis, Lithuanian Academic Libraries Network (LABT), 2004. http://vddb.library.lt/obj/LT-eLABa-0001:E.02~2004~D_20040616_143628-98619.

Full text
Abstract:
In this paper is present information about dry power transformers mechanical design, common electrical characteristics, and electrical characteristics. There compare oil transformers and dry power transformers. There are given conclusions about possible in practice use dry transformers and some to offer a suggestion how to pick and choose transformers.
APA, Harvard, Vancouver, ISO, and other styles
23

Meinert, Michael [Verfasser]. "Hochtemperatursupraleitende Transformatoren für künftige Schienenfahrzeuge / Michael Meinert." Aachen : Shaker, 2007. http://d-nb.info/1166512118/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Mousavi, Takami Kourosh. "Process Control and Simulation of Ferromagnetic Strip in the Power Transformers and Electrical Machines Applications : Electric power systems." Doctoral thesis, Västerås : School of Sustainable Development of Sociaty and Technology, Mälardalen University, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-6648.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Freshwater, Dawn. "Transformatory learning in nurse education." Thesis, University of Nottingham, 1998. http://eprints.nottingham.ac.uk/11580/.

Full text
Abstract:
This study aimed to explore the effects of a transformatory learning programme in a group of Project 2000 nursing students. A secondary focus of the study was to monitor the effectiveness of reflexive action research as a tool for reducing the theory-practice gap that persists between nurse education and nursing practice. The learning programme was developed around the process of reflection and evaluated within a framework of a hierarchical model of nursing research and critical social theory. The first level of research used formal theory to generate an action strategy with a group of first year student nurses (n=42). The action strategy was evaluated after an initial period of six months and provided the data for the level two research. The level two research facilitated a macro view of the learning situation which was then examined in more detail for the level three research. Reflection on action was adopted as the method of generating informal theory with the aim of facilitating a micro view of the learning environment. Data was collected using a variety of strategies, both within methods and across methods triangulation assisted a holistic view of the phenomena under exploration. The process of transformatory leaning was found to be a notable factor in developing reflective and effective practice amongst student nurses. Additionally, reflexive action research proved an effective strategy for narrowing the theory-practice gap. The insights gained from the study have considerable significance for informing the future practice of teaching in nursing, not least the challenge that teachers, like nurses, have a professional obligation to develop and review their practical knowledge and explore the effectiveness of their practice. It is proposed that reflexive action research and reflective practice are an appropriate formula for addressing these issues.
APA, Harvard, Vancouver, ISO, and other styles
26

Andersson, Carl Fredrik. "50 kVA eller 100 kVA : En teknisk och ekonomisk jämförelse av distributionstransformatorer." Thesis, Högskolan Väst, Institutionen för ingenjörsvetenskap, 2010. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-2730.

Full text
Abstract:
Rapporten utreder om distributionstransformatorer med märkeffekten 50 kVA i Vattenfall Eldistribution AB:s elnät kan avskaffas till förmån för märkeffekten 100 kVA. Transformatorer med märkeffekten 50 kVA förekommer vid nedtransformering av spänningen från 22 kV och 11 kV till hushållens huvudspänning 0,4 kV. 50 kVA-transformatorer skiljer inte särskilt mycket från transformatorer med den högre märkeffekten i fråga om storlek och pris, och de bedöms kunna bytas ut utan större praktiska svårigheter. Fördelen med 100 kVA är att de elektriska belastningsförlusterna blir lägre i och med den högre märkeffekten. Dessutom innebär ett byte vissa elkvalitetsförbättringar. Nackdelarna med 100 kVA är att de elektriska tomgångsförlusterna är högre och att inköpspriset är högre än för 50 kVA. I övrigt kan kostnaderna likställas för de två alternativen. Endast kostnader för aktiva effektförluster berördes i rapporten då de ekonomiska kostnaderna för reaktiva effektförluster kunde försummas för de aktuella transformatorerna. För att nå ett svar på frågan om det kan vara lönsamt att avskaffa 50 kVA-transformatorerna studerades fem verkliga fall i Vattenfalls svenska elnät. Dessutom studerades eventuella elkvalitetsvinster med ett byte. Svaret blev att inte för något av de fem studerade fallen var det lönsamt med ett byte till 100 kVA-transformator. Rörande elkvalitetsaspekten blev svaret att ett byte visserligen innebär en skillnad men att andra faktorer oftast har större betydelse. Rapportens rekommendation blev att behålla 50 kVA-transformatorn i distributionsnätet.
APA, Harvard, Vancouver, ISO, and other styles
27

Gogoulou, Evangelina. "Using Bidirectional Encoder Representations from Transformers for Conversational Machine Comprehension." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-265656.

Full text
Abstract:
Bidirectional Encoder Representations from Transformers (BERT) is a recently proposed language representation model, designed to pre-train deep bidirectional representations, with the goal of extracting context-sensitive features from an input text [1]. One of the challenging problems in the field of Natural Language Processing is Conversational Machine Comprehension (CMC). Given a context passage, a conversational question and the conversational history, the system should predict the answer span of the question in the context passage. The main challenge in this task is how to effectively encode the conversational history into the prediction of the next answer. In this thesis work, we investigate the use of the BERT language model for the CMC task. We propose a new architecture, named BERT-CMC, using the BERT model as a base. This architecture includes a new module for encoding the conversational history, inspired by the Transformer-XL model [2]. This module serves the role of memory throughout the conversation. The proposed model is trained and evaluated on the Conversational Question Answering dataset (CoQA) [3]. Our hypothesis is that the BERT-CMC model will effectively learn the underlying context of the conversation, leading to better performance than the baseline model proposed for CoQA. Our results of evaluating the BERT-CMC on the CoQA dataset show that the model performs poorly (44.7% F1 score), comparing to the CoQA baseline model (66.2% F1 score). In the light of model explainability, we also perform a qualitative analysis of the model behavior in questions with various linguistic phenomena eg coreference, pragmatic reasoning. Additionally, we motivate the critical design choices made, by performing an ablation study of the effect of these choices on the model performance. The results suggest that fine tuning the BERT layers boost the model performance. Moreover, it is shown that increasing the number of extra layers on top of BERT leads to bigger capacity of the conversational memory.
Bidirectional Encoder Representations from Transformers (BERT) är en nyligen föreslagen språkrepresentationsmodell, utformad för att förträna djupa dubbelriktade representationer, med målet att extrahera kontextkänsliga särdrag från en inmatningstext [1]. Ett utmanande problem inom området naturligtspråkbehandling är konversationsförståelse (förkortat CMC). Givet en bakgrundstext, en fråga och konversationshistoriken ska systemet förutsäga vilken del av bakgrundstexten som utgör svaret på frågan. Den viktigaste utmaningen i denna uppgift är hur man effektivt kan kodifiera konversationshistoriken i förutsägelsen av nästa svar. I detta examensarbete undersöker vi användningen av BERT-språkmodellen för CMC-uppgiften. Vi föreslår en ny arkitektur med namnet BERT-CMC med BERT-modellen som bas. Denna arkitektur innehåller en ny modul för kodning av konversationshistoriken, inspirerad av Transformer-XL-modellen [2]. Den här modulen tjänar minnets roll under hela konversationen. Den föreslagna modellen tränas och utvärderas på en datamängd för samtalsfrågesvar (CoQA) [3]. Vår hypotes är att BERT-CMC-modellen effektivt kommer att lära sig det underliggande sammanhanget för konversationen, vilket leder till bättre resultat än basmodellen som har föreslagits för CoQA. Våra resultat av utvärdering av BERT-CMC på CoQA-datasetet visar att modellen fungerar dåligt (44.7% F1 resultat), jämfört med CoQAbasmodellen (66.2% F1 resultat). För att bättre kunna förklara modellen utför vi också en kvalitativ analys av modellbeteendet i frågor med olika språkliga fenomen, t.ex. koreferens, pragmatiska resonemang. Dessutom motiverar vi de kritiska designvalen som gjorts genom att utföra en ablationsstudie av effekten av dessa val på modellens prestanda. Resultaten tyder på att finjustering av BERT-lager ökar modellens prestanda. Dessutom visas att ökning av antalet extra lager ovanpå BERT leder till större konversationsminne.
APA, Harvard, Vancouver, ISO, and other styles
28

Dumke, Knut. "Untersuchungen an einer Esterflüssigkeit als Isolierstoff für Transformatoren /." Düsseldorf : VDI-Verl, 1999. http://www.gbv.de/dms/bs/toc/270224106.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Dragana, Naumović Vuković. "Prilog savremenom etaloniranju strujnih mernih transformatora." Phd thesis, Univerzitet u Novom Sadu, Fakultet tehničkih nauka u Novom Sadu, 2018. https://www.cris.uns.ac.rs/record.jsf?recordId=107383&source=NDLTD&language=en.

Full text
Abstract:
U ovoj doktorskoj disertaciji prikazana je koncepcija, realizacija i potvrda nove metodejednovremenog etaloniranja strujnih mernih transformatora sa dve različite merneaparature. Pregledom stručne literature ne postoji podatak da je ova metoda ranijeprimenjivana. U disertaciji su prikazane različite merne metode za ispitivanje ietaloniranje mernih transformatora koje imaju primenu u savremenoj praksi i kojepodrazumevaju i različite merne mogućnosti. Takođe je i ekperimentalno potvrđenojednovremeno ispitivanje i etaloniranje strujnih mernih transformatora sa nekolikomernih aparatura koje su zasnovane na različitim metodama. Sprovedna istraživanja ieksperimentalni rezultati pokazuju i potvrđuju niz prednosti ovakvog načinaetaloniranja. Detaljna analiza komponenti merne nesigurnosti pokazala je da seprimenom ove metode postiže poboljšanje merne nesigurnost etaloniranja za skoro redveličine u odnosu na klasično pojedinačno etaloniranje sa dve različite merneaparature. Analiza uticajnih veličina na mernu nesigurnost pokazuje da se po ovoj novojmetodi etaloniranja eliminiše niz komponenti od kojih su najznačajnije: uticajnejednakosti referentnih struja i ispitnog opterećenja. Istraživanja su takođe pokazalada jednovremena metoda osim što doprinosi podizanju tačnosti etaloniranja strujnihtransformatora, ima primenu i u etaloniranju mernih aparatura za ispitivanje tačnostimernih transformatora i interkonparaciji strujnih etalon transformatora. Krozkonkretne primere realizovane u praksi, razmotreni su i prikazani načini etaloniranjamernih aparatura za ispitivanje tačnosti ovom novom metodom. Interkomparacijom dvamerna sistema visoke klase tačnosti Nacionalnog merološkog instituta Kanade(National Research Council Canada), od kojih je jedna razvijena u ElektrotehničkomInstitutu "Nikola Tesla", pokazana je i prednost primene jednovremene metode u oblastiprimarne metrologije strujnih mernih transformatora.
The dissertation presents the concept, its realisation and verification of the new methodof simultaneous comparison of the current transformers by two different measuringapparatus. It is shown by searching the literature, that this method has not been usedbefore. In this dissertation different measuring methods for testing and calibration ofcurrent transformers, with their different measuring capabilities are presented. Most ofthem have been used in recent practice. Furthermore, the experimental verification ofnew simultaneous calibration method is presented. For this reason some measuringapparatus based on different measuring methods were used. Conducted research andexperimental results confirmed a number of advantages of this calibration method.Detailed analysis of the components of the uncertainty of measurements shown thatusing simultaneous method uncertainty of measurements have been improvedcomparing to method with two individual calibration by different apparatus. In that casesome of the measuring uncertainty components can be neglected. The most significantis component caused by variation of referent current and component caused by variationof burden. The research has also showed that simultaneous method can be used forcalibration of measuring apparatus for current transformer accuracy testing and theirinter-comparisons. The ways of calibration of apparatus for current transformer accuracytesting are considered and presented, through concrete examples realized in practice.A high-accuracy comparison of two NRC (National Research Council Canada)calibration systems were carried out by new simultaneous method. One measuringsystem is developed at Electrical Engineering institute Nicola Tesla, Belgrade.Accordingly the advantage of simultaneous method applied at the primary metrology ofcurrent transformer is verified.
APA, Harvard, Vancouver, ISO, and other styles
30

Berger, André [Verfasser], and M. [Akademischer Betreuer] Noe. "Entwicklung supraleitender, strombegrenzender Transformatoren / André Berger ; Betreuer: M. Noe." Karlsruhe : KIT Scientific Publishing, 2011. http://d-nb.info/1185581553/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

Semberg, Tobias. "Byggnation och mätning av kabellindad variabel transformator." Thesis, Uppsala universitet, Institutionen för teknikvetenskaper, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-162793.

Full text
Abstract:
The output voltage from the vertical axis wind turbines, build at Uppsala University, varies in the sense that it increases with the speed of the wind. To get a steady output from these wind turbines a stepless adjustable transformer was constructed. The transformer is cable wound and is adjusted by moving the turns from working with the magnetic field to working against it. With this technique the same cable can be used twice, as a consequence, half the amount of cable is required and the size of the transformer is reduced. The results from the report are that no losses can be connected exclusively to the regulating part of the transformer. No transients of significance occur when the transformer is regulated on load.
APA, Harvard, Vancouver, ISO, and other styles
32

Mutaliev, Mohammed, and Ibrahim Almimar. "Optimering av en chattbot för det svenska språket." Thesis, KTH, Hälsoinformatik och logistik, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-296616.

Full text
Abstract:
Chattbotutvecklare på Softronic använder i dagsläget Rasa-ramverket och dess standardkomponenter för bearbetning av användarinmatning. Det här är problematiskt då standardkomponenterna inte är optimerade för det svenska språket. Till följd av detta efterfrågades en utvärdering av samtliga Rasa-komponenter med syfte att identifiera de mest gynnsamma komponenterna för att maximera klassificeringsträffsäkerhet. I detta examensarbete framtogs och jämfördes flera Rasa-pipelines med olika komponenter för tokenisering, känneteckensextrahering och klassificering. Resultaten av komponenterna för tokenisering visade att Rasas WhitespaceTokenizer överträffade både SpacyTokenizer och StanzaTokenizer. För känneteckensextrahering var CountVectorsFeaturizer, LanguageModelFeaturizer (med LaBSE-modellen) och FastTextFeaturizer (med den officiella fastText-modellen tränad på svenska Wikipedia) de mest optimala komponenterna. Den klassificerare som i allmänhet presterade bäst var DIETClassifier, men det fanns flera tillfällen där SklearnIntentClassifier överträffade den.   Detta arbete resulterade i flera pipelines som överträffade Rasas standard-pipeline. Av dessa pipelines var det två som presterade bäst. Den första pipeline implementerade komponenterna WhitespaceTokenizer, CountVectorsFeaturizer, FastTextFeaturizer (med den officiella fastText-modellen tränad på svenska Wikipedia) och DIETClassifier med en klassificeringsträffsäkerhet på 91% (F1-score). Den andra pipeline implementerade komponenterna WhitespaceTokenizer, LanguageModelFeaturizer (med LaBSE-modellen) och SklearnIntentClassifier med en klassificeringsträffsäkerhet på 91,5% (F1-score).
Chatbot developers at Softronic currently use the Rasa framework and its default components for processing user input. This is problematic as the default components are not optimized for the Swedish language. Following this an evaluation of all Rasa components was requested with the purpose of identifying the most favorable components to maximize classification accuracy. In this thesis, several Rasa pipelines were developed and compared with different components for tokenization, feature extraction and classification. The results of the tokenization components showed that Rasa's WhitespaceTokenizer surpassed both SpacyTokenizer and StanzaTokenizer. For feature extraction, CountVectorsFeaturizer, LanguageModelFeaturizer (with the LaBSE model) and FastTextFeaturizer (with the official fastText model trained on Swedish Wikipedia) were the most optimal components. The classifier that generally performed best was DIETClassifier, but there were several occasions where SklearnIntentClassifier surpassed it. This work resulted in several pipelines that exceeded Rasa’s standard pipeline. Of these pipelines, two performed best. The first pipeline implemented the components WhitespaceTokenizer, CountVectorsFeaturizer, FastTextFeaturizer (with the official fastText model trained on Swedish Wikipedia) and DIETClassifier with a classification accuracy of 91% (F1 score). The other pipeline implemented the components WhitespaceTokenizer, LanguageModelFeaturizer (with the LaBSE model) and SklearnIntentClassifier with a classification accuracy of 91.5% (F1 score).
APA, Harvard, Vancouver, ISO, and other styles
33

Holm, Henrik. "Bidirectional Encoder Representations from Transformers (BERT) for Question Answering in the Telecom Domain. : Adapting a BERT-like language model to the telecom domain using the ELECTRA pre-training approach." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-301313.

Full text
Abstract:
The Natural Language Processing (NLP) research area has seen notable advancements in recent years, one being the ELECTRA model which improves the sample efficiency of BERT pre-training by introducing a discriminative pre-training approach. Most publicly available language models are trained on general-domain datasets. Thus, research is lacking for niche domains with domain-specific vocabulary. In this paper, the process of adapting a BERT-like model to the telecom domain is investigated. For efficiency in training the model, the ELECTRA approach is selected. For measuring target- domain performance, the Question Answering (QA) downstream task within the telecom domain is used. Three domain adaption approaches are considered: (1) continued pre- training on telecom-domain text starting from a general-domain checkpoint, (2) pre-training on telecom-domain text from scratch, and (3) pre-training from scratch on a combination of general-domain and telecom-domain text. Findings indicate that approach 1 is both inexpensive and effective, as target- domain performance increases are seen already after small amounts of training, while generalizability is retained. Approach 2 shows the highest performance on the target-domain QA task by a wide margin, albeit at the expense of generalizability. Approach 3 combines the benefits of the former two by achieving good performance on QA both in the general domain and the telecom domain. At the same time, it allows for a tokenization vocabulary well-suited for both domains. In conclusion, the suitability of a given domain adaption approach is shown to depend on the available data and computational budget. Results highlight the clear benefits of domain adaption, even when the QA task is learned through behavioral fine-tuning on a general-domain QA dataset due to insufficient amounts of labeled target-domain data being available.
Dubbelriktade språkmodeller som BERT har på senare år nått stora framgångar inom språkteknologiområdet. Flertalet vidareutvecklingar av BERT har tagits fram, bland andra ELECTRA, vars nyskapande diskriminativa träningsprocess förkortar träningstiden. Majoriteten av forskningen inom området utförs på data från den allmänna domänen. Med andra ord finns det utrymme för kunskapsbildning inom domäner med områdesspecifikt språk. I detta arbete utforskas metoder för att anpassa en dubbelriktad språkmodell till telekomdomänen. För att säkerställa hög effektivitet i förträningsstadiet används ELECTRA-modellen. Uppnådd prestanda i måldomänen mäts med hjälp av ett frågebesvaringsdataset för telekom-området. Tre metoder för domänanpassning undersöks: (1) fortsatt förträning på text från telekom-området av en modell förtränad på den allmänna domänen; (2) förträning från grunden på telekom-text; samt (3) förträning från grunden på en kombination av text från telekom-området och den allmänna domänen. Experimenten visar att metod 1 är både kostnadseffektiv och fördelaktig ur ett prestanda-perspektiv. Redan efter kort fortsatt förträning kan tydliga förbättringar inom frågebesvaring inom måldomänen urskiljas, samtidigt som generaliserbarhet kvarhålls. Tillvägagångssätt 2 uppvisar högst prestanda inom måldomänen, om än med markant sämre förmåga att generalisera. Metod 3 kombinerar fördelarna från de tidigare två metoderna genom hög prestanda dels inom måldomänen, dels inom den allmänna domänen. Samtidigt tillåter metoden användandet av ett tokenizer-vokabulär väl anpassat för båda domäner. Sammanfattningsvis bestäms en domänanpassningsmetods lämplighet av den respektive situationen och datan som tillhandahålls, samt de tillgängliga beräkningsresurserna. Resultaten påvisar de tydliga vinningar som domänanpassning kan ge upphov till, även då frågebesvaringsuppgiften lärs genom träning på ett dataset hämtat ur den allmänna domänen på grund av otillräckliga mängder frågebesvaringsdata inom måldomänen.
APA, Harvard, Vancouver, ISO, and other styles
34

Zorin, Aleksej. "Akmenės transformatorių pastotės elektros tinklo patikimumo didinimo priemonės." Master's thesis, Lithuanian Academic Libraries Network (LABT), 2013. http://vddb.laba.lt/obj/LT-eLABa-0001:E.02~2013~D_20130618_154914-38953.

Full text
Abstract:
Šiame darbe nagrinėjamos Akmenės transformatorių pastotės elektros tinklo gedimų bei patikimumo didinimo problemos, remiantis mokslinės literatūros analize ir praktinio darbo patirties apibendrinimu. Nustatomi Akmenės transformatorių pastotės elektros tinklo 0,4-10 kV linijų gedimų skaičius, atjungtų vartotojų skaičius, atjungimų trukmės ir priežastys. Apskaičiuojami Akmenės transformatorių pastotės elektros tinklo patikimumo rodikliai, daugiausiai gendančios elektros linijos parengties ir priverstinės prastovos koeficientai bei gedimo ir veikimo tikimybės per 12 mėnesių.
This paper deals with Akmenės transformer substation power supply failure, and increase the robustness of the problem based on the scientific literature and practical experience summary. Setting Akmenės transformer substation power supply 0.4-10 kV line number of faults, the number of disconnection, disconnection times and causes. Calculate Akmenės transformer substation power supply reliability indicators, mostly perishable standby power lines and forced inactivity rates and the probability of failure and operational within 12 months.
APA, Harvard, Vancouver, ISO, and other styles
35

Dejana, Herceg. "Modelovanje mernih transformatora bez jezgra sa feromagnetskim oklopom." Phd thesis, Univerzitet u Novom Sadu, Fakultet tehničkih nauka u Novom Sadu, 2016. https://www.cris.uns.ac.rs/record.jsf?recordId=96158&source=NDLTD&language=en.

Full text
Abstract:
U ovoj doktorskoj tezi razvijen je postupak za ispitivanje uticajaoklopa na merni transformator bez jezgra sa stanovištalinearnosti transformatora i zaštite transformatora oduticaja elektromagnetske smetnje. Formiran je parametarski modeloklopa i mernog transformatora bez jezgra. Izvedena su merenjamagnetskih karakteristika feromagnetskih materijala, dat je novianalitički model histerezisa i određene su krive magnetisanja ipermeabilnosti materijala. Na osnovu numeričkih ieksperimentalnih rezultata, a u skladu sa definisanimkriterijumom, izvršena je analiza kvaliteta oklapanja zarazmatrane tipove oklopa.
In this thesis a method for examining the effects of shielding on a corelessmeasuring transformer from the standpoint of transformer linearity and EMradiation shielding is developed. A parametric model of the shield and thecoreless measuring transformer is constructed. Measurements of magneticproperties of ferromagnetic materials were performed; a new analytical modelof hysteresis is developed; magnetization curves and permeability of thematerials are determined. Based on numerical and experimental results, andusing the defined criterion, the analysis of shielding quality of the consideredshield types was performed.
APA, Harvard, Vancouver, ISO, and other styles
36

Schwarzmann, Holger [Verfasser], and Heiner [Akademischer Betreuer] Ryssel. "Piezoelektrische Transformatoren zur Ansteuerung von Leistungsschaltern / Holger Schwarzmann. Betreuer: Heiner Ryssel." Erlangen : Universitätsbibliothek der Universität Erlangen-Nürnberg, 2012. http://d-nb.info/1021259748/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Hoffmann, Holger [Verfasser]. "Elektronischer Transformator für Hochleistungs-Traktionssysteme am Wechselspannungsnetz / Holger Hoffmann." München : Verlag Dr. Hut, 2012. http://d-nb.info/1029400326/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Bratt, Adam, and Hernekoski José Luis Jimenez. "Övertoner från UPS i transformator : Lokalisering och möjliga lösningar." Thesis, Högskolan i Borås, Akademin för textil, teknik och ekonomi, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:hb:diva-23434.

Full text
Abstract:
Avsikten med rapporten är att kartlägga och analysera förekommande övertoner i anslutning till en utav AstraZenecas Uninteruptible Power Supply (UPS) anläggningar. Samt ge en generell inblick på övertoner och dess karaktäristik i form av konsekvenser och lösningar. Analysen har skett genom mätningar med två olika instrument, en ultraljudsmikrofon och en nätanalysator. Ultraljudsmikrofonen mäter ljudfrekvenser i luften som kan kopplas till vibrationerna alstrade av övertonerna i transformatorerna. Nätanalysatorn användes i syfte att mäta övertonerna i direkt anslutning till ledningarna och ge en komplett bild av de tre fasernas vågform. Valet att använda ultraljudsmikrofonen och nätanalysatorn baserades på att ha en tvåfaldig bekräftelse av förekommande övertoner. Då två olika datainsamlingsmetoder ökar trovärdigheten i resultaten, ifall dessa överensstämmer. Resultaten visade förekomsten av 2:a, 5:e, 7:e, 11:e och 13:e strömövertoner. Dessa uppmättes i en punkt emellan transformatorn före UPS:en och UPS:en i sig. Källan till strömövertonerna är 6-puls likriktaren ansluten inuti UPS:en. Spänningens vågform påvisade inga större övertoner utan föll inom normala gränsvärden, vilket är ett resultat av att mätningen utfördes på inkommande sida av UPS:en. Efter UPS uppmättes kraftigare övertoner än före. Dessa sträckte sig ifrån 2:a till 7:e ordningen och bestod av både jämna och udda övertoner. Orsaken anses vara växelriktarens hackande av batteriets likspänning, samt pulse width modulation (PWM)-tekniken. Ultraljudsmikrofonens förmåga visade sig vara mindre anpassad för ändamålet i jämförelse med nätanalysatorn, då den inte påvisade utslag på de kraftigaste övertonerna uppmätta med nätanalysatorn. Nätanalysatorn var nyckelinstrumentet som bekräftade förekomsten av övertoner ifrån en 6-pulsbrygga före UPS och växelriktarens spår efter UPS. Konsekvenser orsakade av övertonerna framgick som slitage på materiel, onödiga energiförluster och värmeutveckling i ledningar och komponenter. Lösningarna består utav diverse filter eller ombyggnationer. Dessa åtgärder ansågs inte vara ett självklart val ur ett ekonomiskt perspektiv då skadeverkan anses låg.
The purpose of this report is to map and analyse the existing harmonics in connection with one of AstraZeneca´s Uninterruptible Power Supply (UPS) stations. Additionally, give a general insight of the harmonic distortion’s characteristics accompanied by their consequences and solutions. The analysis was carried out using two different instruments, an ultrasound microphone and a network analyser. The ultrasound microphone measures sound frequencies in the air which can be associated with the vibrations produced by the harmonics in the transformer. The network analyser was used with the intent to measure the harmonic distortions directly on the powerline in order to give a complete picture of the three phase’s waveform. The decision to use two different instruments was to achieve a twofold confirmation of the present harmonics. In the case of correlation between the two. The results showed the presence of 2nd, 5th, 7th, 11th and 13th harmonics in the current’s distortion. These were measured in a point between the transformer before the UPS and the UPS itself. The source of the harmonic distortion is the 6-pulse rectifier inside the UPS. The harmonic distortion found inside the voltage showed no sign of exceeding regular harmonic distortion levels, which is a result of the measurements taking place on the incoming line of the UPS. After the UPS, the measurements showed greater harmonics than the measurement before the UPS. These harmonics included both even and odd going from the 2nd to 7th order. The cause seems to be the inverter’s switching of the batteries DC-voltage together with the pulse width modulation (PWM)-technology. The ultrasound microphones ability proved to be less adapted for this purpose in comparison to the network analyser since it did not pick up the strongest harmonics showed by the network analyser. The network analyser proved to be the key instrument for measuring the harmonics associated with the 6-pulsebridge, which exclusively can be pointed out as belonging to the rectifier in the UPS station. The network analyser also traced the tracks left by the inverter after the UPS. The consequences caused by the harmonic distortion spawns in the shape of excessive wear, unnecessary energy losses and heat increase in power lines and components. The solutions for this matter are various types of filters or reconstruction of components. These actions are not deemed as an obvious choice from economic standpoint due to the low estimated damage caused by the harmonics.
APA, Harvard, Vancouver, ISO, and other styles
39

Voss, Stephan. "Semianalytische Modellierung elektrischer Ersatzschaltbilder für drahtgewickelte Spulen und Transformatoren in der Leistungselektronik." [S.l.] : [s.n.], 2006. http://deposit.ddb.de/cgi-bin/dokserv?idn=980372631.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Wenzel, Dirk. "Teilentladungsmessungen an Transformatoren im Netz mit Verfahren der digitalen Signalverarbeitung und Mustererkennung /." Düsseldorf : VDI-Verl, 1998. http://www.gbv.de/dms/bs/toc/252628284.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Nogerius, David. "Dimensionering av hjälptransformator." Thesis, Uppsala universitet, Nanoteknologi och funktionella material, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-191874.

Full text
Abstract:
The aims of the following project has beento make a proposition how to create aspecific kind of transformer. Thefollowing report evaluates the differentimportant variables and contains asuggestion for a possible design. Intheory it's an ordinary transformer that'ssuppose to transform electrical effect toa high voltage line. The design of thetransformer is using an already existingcurrent transformer design and is adjustedto work for it's specific purpose. Theproject also contains the developing of atransformer simulation model that will beused to evaluate and optimize thedimensions of the resulting transformer.
APA, Harvard, Vancouver, ISO, and other styles
42

Fransson, David. "Projektering av elkraftanläggning för fläktprov : dimensionering av transformator, kablar mm." Thesis, Växjö University, School of Mathematics and Systems Engineering, 2006. http://urn.kb.se/resolve?urn=urn:nbn:se:vxu:diva-808.

Full text
Abstract:

Fläkt Woods har ett fläktlab i Växjö där man utför kund och leveransprover av axiella fläktar.

Befintlig anläggning är i dag bristfällig när det gäller driftsäkerhet och personsäkerhet. Även möjligheten att köra varvtalsreglerat är idag begränsad.

Uppgiften är att projektera en ny anläggning omfattande en ny jordkabel, mellan- och lågspänningsställverk, transformatorer, kopplingsutrustningar och frekvensomriktare.

APA, Harvard, Vancouver, ISO, and other styles
43

Magnusson, Lisa. "DESIGN IMPROVEMENTS OF DISTRIBUTION TRANSFORMERS : How to improve conditions of transportation in Vietnam." Thesis, Högskolan i Skövde, Institutionen för ingenjörsvetenskap, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:his:diva-10500.

Full text
Abstract:
Nowadays international companies wish to relocate their production to developing countries in Asia. The product design is often developed in Europe and is, therefore, not always adapted to the production (transport and manufacture conditions) present in the country of manufacture. The consequence is less qualitative products e.g. distribution transformers of ABB Vietnam get damaged during transport; a problem none existing in Europe. The purpose of the project was to develop the design of distribution transformers for ABB Vietnam, so they better withstand the transport conditions. This Bachelor Degree Project in Integrated Product Development follow a general design process typically for product development and is divided into four main phases. The four faces are; Exploration (of the ill-defined problem space), Generation (of concepts), Evaluation (of the design proposals), and Communication (of the final design solution). Methodologies as literature studies and empirical investigations (observations and interviews) performed at the ABB Vietnam factory in Hanoi provided information about the problem space and a brief overview of the production of ABB transformers. In the study it emerged that the underlying problem was due to both the structure of the product and the infrastructure of the country, e.g. extreme road conditions, lower standard of transportation means etc. Design methodologies were implemented to systematically create ideas, generate and evaluate a number of concepts. The final design concept chosen was simulated to behaviour adequately of transport in real life to verify that the concept manage its purpose. The concept can be further improved and optimised. The outcome of the study revealed the possibilities of improvement, designers can contribute to increased quality of products by understanding the country of manufacture. The thesis is intended to enlighten people working with product development what they shall consider when designing for transportation, and may be used as a practical example of similar problems. The final design concept is an external support frame attached to the transformer to enhance support and contribute to improved quality – especially under extreme road conditions.
Internationella företag vill idag flytta sin produktion till utvecklingsländer i Asien. Deras produkter vars design har utvecklats i Europa är därmed inte alltid anpassade till transport- och tillverkningsförhållanden som finns i tillverkningslandet. Konsekvensen blir mindre kvalitativa produkter. Ett exempel på detta problem är distributionstransformatorer från ABB Vietnam som skadas under vägtransporter pga. dåliga vägar, ett problem som är omärkbart i Europa. Syftet med projektet var därför att analysera och utveckla designen av distributionstransformatorer, för ABB Vietnam, så att de bättre klarar av de svåra vägtransporterna. Detta examensarbete inom Integrerad Produktutveckling följer den allmänna designprocessen typiskt för produktutveckling och består av fyra faser som inkluderar Utforskning (av det vagt definierade problemområdet), Generering (av koncept), Utvärdering (av designförslag) och Kommunicering (av det slutgiltiga designförslaget). Metoder som litteraturstudier och empiriska undersökningar (observationer och intervjuer) utfördes på ABB Vietnam, i fabriken som ligger i Hanoi. Därifrån uppdagades information om problemområdet och en översikt över produktionen av ABB transformatorer. I studien framkom att det underliggande problemet berodde på en kombination av produktens struktur och landets infrastruktur t.ex. extrema vägförhållanden, lägre standard för transportmedel, etc. För att systematiskt skapa nya idéer implementerades diverse designmetoder, för att utveckla och värdera ett antal koncept. Det slutliga designkonceptet som valdes simulerades med avseende på verkliga transportförhållanden för att verifiera att konceptet kommer att motstå dessa påkänningar. Konceptet kan förbättras och optimeras ytterligare. Resultatet av studien visade att designers kan bidra till förbättringar och öka kvaliteten på produkter genom att förstå förhållanden i tillverkningslandet. Studien syftar till att upplysa vad de som arbetar med produktutveckling ska tänka på när de designar för transport och den kan användas som ett praktiskt exempel för liknande problem. Det slutliga designkonceptet är en extra stödram fäst på transformatorn för att öka transformatorns hållbarhet och förbättra kvaliteten - särskilt under extrema vägförhållanden.
APA, Harvard, Vancouver, ISO, and other styles
44

Al-Yakoubi, Murad, and Elias Roham. "Underhåll och övervakning av distributionstransformatorer." Thesis, Linnéuniversitetet, Institutionen för datavetenskap, fysik och matematik, DFM, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-30749.

Full text
Abstract:
Följande projekt går i korthet ut på att avgöra om användning av kylsystemet i en transformatorstation är relevant, om det minimerar temperaturhöjningen orsakad av effektförlusterna som transformatorn avger. Arbetet ska resultera i förslag på val av transformatorer samt beskriva dess egenskaper. Vidare vill vi finna lösningar kring problemet med överhettning i transformatorstationerna och att de generella kraven såsom låg ljudnivå och tillräcklig ventilation (för att ta bort den värmeförlust som de inre komponenterna avger) skall uppfyllas.  För att kunna ge olika förslag på val av transformator i transformatorstationerna har vi på Holtab AB utfört olika beräkningar som visar skillnad för pris, kvalitet, livslängd och egenskaper (effektförluster, energiförluster).
APA, Harvard, Vancouver, ISO, and other styles
45

Wästljung, Martin. "Ny stamstation i Yttermalung för anslutning av vindkraft : Nätstudie av olika utföranden i normal- och reservdrift." Thesis, Uppsala universitet, Elektricitetslära, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-226929.

Full text
Abstract:
Since 2004, wind power has had the largest installation of new capacity compared to other energy sources in Sweden. Accommodating new wind power may require strengthening or rebuilding of the existing grid in areas where the grid is already loaded to maximum capacity. This master thesis examine the possibility of a new 400/130 kV substation in Yttermalung, Sweden, with a connection to the two neighboring regional grids in Dalarna and Värmland owned by Fortum. This substation would provide a new connection point to the Swedish transmission system as well as an interconnection of the two, currently separated, regional grids. Different expansion scenarios where a substation with and without series compensation or a phase shifting transformer (PST) to control active power flow were studied. A total of 650MW new wind power farms connected in six different locations were also included in the scenarios. Load flow, contingency studies and fault currents were calculated for the scenarios in the software tool Power System Simulator for Engineering. The study shows that the new substation would improve redundancy of the regional grids, decrease loading of many branches and only affect voltage marginally, however increased fault currents can be expected in stations located close to the new substation. It is possible to connect the modelled wind power farms, provided that power output is regulated at sensitive parts of the grid during critical operating conditions. Värmland’s regional grid experiences unwanted power flow through the system but only during uncritical loading conditions. The unwanted power flow can be prevented, most efficiently by connecting a PST to Värmland’s regional grid. This can also be installed later on after the substation has been commissioned, when the amount of wind power connections require it.
APA, Harvard, Vancouver, ISO, and other styles
46

Hollinshead, Sophie. "Transformatory landscapes : spaces of health, reform and education on the Lincolnshire coast." Thesis, University of Nottingham, 2016. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.716673.

Full text
Abstract:
My research examines activity on the Lincolnshire coast that might lead to an identification of this landscape as transformatory. These transformations are affected on individuals through interaction with institutional spaces concerned with health, education and reform, from which participants might engage directly with the landscape in order to benefit health and moral wellbeing. During the late 19th and 20th centuries the Lincolnshire coast saw the development of institutions that aimed to heal, restore, reform and educate. These institutions were often on the edge of towns or between the leisure resorts; marginalised they operated in different, albeit consecutive spaces, to those of the resident, worker or holiday maker. These institutional spaces provided the focus for specific social, welfare, health and educational concerns which used the landscape as a tool for personal transformation, during a period that saw increasing state involvement in health, education and welfare, as well as the growth of the Lincolnshire coast as a seaside resort. These institutions were largely used by those who were from beyond east Lincolnshire; often travelling from Midland cities to the supposedly health­giving coast they would experience these landscapes and spaces as outsiders giving a particular sense of space, as both positive and negative. The institutions studied here comprise two educational field centres, at Freiston and at Gibraltar Point, two convalescent homes, the Derbyshire Miners Convalescent Home at Skegness and the Lincolnshire Seaside Convalescent Home at Mablethorpe, and two reformatory institutions, North Sea Camp Borstal and The Lincoln Diocesan Home.
APA, Harvard, Vancouver, ISO, and other styles
47

Beringer, Sebastian [Verfasser]. "Prozessentwicklung zur Fertigung von substratlosen Mikrosystemen am Beispiel eines Mikro-Transformators / Sebastian Beringer." Garbsen : TEWISS - Technik und Wissen GmbH, 2021. http://d-nb.info/1228009910/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
48

Giorgis, Stavros. "Evaluation of Approaches for Representation and Sentiment of Customer Reviews." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-291214.

Full text
Abstract:
Classification of sentiment on customer reviews is a real-world application for many companies that offer text analytics and opinion extraction on customer reviews on different domains such as consumer electronics, hotels, restaurants, and car rental agencies. Natural Language Processing’s latest progress has seen the development of many new state-of-the-art approaches for representing the meaning of sentences, phrases, and words in the text using vector space models, so-called embeddings. In this thesis, we evaluated the most current and most popular text representation techniques against traditional methods as a baseline. The evaluation dataset consists of customer reviews from different domains with different lengths used by a text analysis company. Through a train dataset exploration, we evaluated which datasets were the most suitable for this specific task. Furthermore, we explored different techniques that could be used to alter a language model’s decisions without retraining it. Finally, all the methods were evaluated against their time performance and the resource requirements to present an overall experimental assessment that could potentially help the company decide which is the most appropriate technique to replace its system in a production environment.
Klassificeringen av attityd och känsloläge i kundrecensioner är en tillämpning med praktiskt värde för flera företag i marknadsanalysbranschen. Aktuell forskning i språkteknologi har etablerat vektorrum som standardrepresentation för ord, fraser och yttranden, så kallade embeddings. Denna uppsats utvärderar den senaste tidens mest framgångsrika textrepresentationsmodeller jämfört med mer traditionella vektorrum. Utvärdering görs genom att jämföra automatiska analyser med mänskliga bedömningar för kundrecensioner av varierande längd från olika domäner tillhandahållna av ett textanalysföretag. Inom ramen för studien har olika testmängder jämförts och olika sätt att modifera en språkmodells klassficering utan om träning. Alla modeller har också jämförts med avseende på resurs- och tidsåtgång för träning för att hjälpa uppdragsgivaren fatta beslut om vilken teknik som utgör den mest ändamålsenliga utvecklingsvägen för dess driftsatta system.
APA, Harvard, Vancouver, ISO, and other styles
49

Molina, Gómez Andrea. "Improved planning of wind farms using dynamic transformer rating." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-287175.

Full text
Abstract:
Due to the increase in electrical demand and renewable penetration, electrical utilities need to improve and optimize the grid infrastructure. Fundamental components in this grid infrastructure are transformers, which are designed conservatively on the base of a static rated power. However, load and weather change continuously and hence, transformers are not used in the most efficient way. For this reason a new technology has been developed: Dynamic transformer rating (DTR). By applying DTR, it is possible to load transformers above the nameplate rating without affecting their life time expectancy. This project goes one step further and uses DTR for the short term and long term wind farm planning. The optimal wind farm is designed by applying DTR to the power transformer of the farm. The optimization is carried out using a Mixed-Integer Linear Programming (MILP) model. In respect of the transformer thermal analysis, the linearized top oil model of IEEE Clause 7 is selected. The model is executed for 4 different types of power transformers: 63 MVA, 100 MVA, 200 MVA and 400 MVA. As result, it is obtained that the net present value for the investment and the capacity of the wind farm increase linearly with respect to the size of the transformer. Then, a sensitivity analysis is carried out by modifying the wind speed, the electricity price, the lifetime of the transformer and the selected weather data. From this sensitivity analysis, it is possible to conclude that wind resources and electricity price are key parameters for the feasibility of the wind farm.
På grund av ökningen av efterfrågan av elektricitet och förnybara energin, elförsörgingsföretag måste förbättras och elnätets infrastruktur måste optimeras. Grundläggande komponenter i elnätet är transformatorer, som är designade konservativt efter en statisk märkeffekt. Laster och vädret ändras dock kontinuerligt, detta betyder att transformatorer inte används på de mest effektiva sätten. Av denna anledning har en ny teknik utvecklats: Dynamisk lastbarhet hos transformatorer (DTR). Genom att applicera DTR, gör det möjligt att belasta en transformator högre än märkdata utan att påverka den förväntade livslängden. Detta projekt går ett steg längre och använder DTR för kort och lång sikts vindkraftparkplaneringar. Den optimala vindkraftparken är designad genom att använda DLT på krafttransformatorn för vindkraftsparken. Optimeringen utförst med hjälp av Mixed-Integer Linear programming (MILP) modell. Gällande transformatorns termiska analys, så valdes den linjäriserade toppoljemodellen av IEEE Clause 7. Modellen var utförd för fyra olika krafttransformatorer: 63 MVA, 100 MVA, 200 MVA och 400 MVA. Resultatet blev att nettonuvärdet för investeringen och kapaciteten av vindkraftsparken ökade linjärt med avseende på storleken på transformatorn. En känslighetsanalys var utförd genom att ändra vindhastigheten, elpriset, livstiden av transformatorn och de valda väderdata. Från känslighetsanalysen så var det möjligt att dra slutsatsen att vindresurser och elpriset är nyckelparametrar för vindkraftsparkens genomförbarhet.
APA, Harvard, Vancouver, ISO, and other styles
50

THIBBLIN, CECILIA. "Managing a business change : framework for measuring and controlling businesses." Thesis, KTH, Entreprenörskap och Innovation, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-147787.

Full text
Abstract:
Todays changing market makes it increasingly important for companies to be able to change and adopt to different market dynamics. Companies that manage to undergo a change often differ from those that fail. Key performance indicators is a tool that enables companies to measure where they stand in relation to other companies, but also to know where they want and where they´re going. Looking at change as inevitable, it´s becoming more common for companies to take outside help from companies who are experts when it comes to change. Studies also shows that a trend shift has taken place the last 15 years, where businesses have become more likely to take help from experts to reduce burden on its own staff but also to be bale to focus on theirordinary activities. Transformator Design is one of those experts and their desire to select the "best" key performers indicators, with a focus on the customer, are the foundation of this thesis. Moreover, the objective of this study is to contribute to the understanding of how companies, in general, should work with change management. The study has, after examination of theory and previous empirical studies, conducted interviews with the five companies SEB, Netsurvey, Telia, Ica and Skandia. Common to these companies is that they are all engaged in change management. The result of the theories shows that there is no general panacea when it comes to the choice of KPI, but it varies depending on the type of business that a company carries. When it comes to the selection of KPI, all firms, regardless of business, should select those that reflect the firm´s business, employees and customers. This is because the customer indirectly is affected by a satisfied business with satisfied employees.
Dagens föränderliga marknad gör det allt mer viktigt för företag att kunna förändra och anpassa sig till olika marknaders dynamik. Företag som lyckas genomgå en förändring skiljer sig ofta från de som går i konkurs. Nyckeltal är ett verktyg som gör det möjligt för företag att mäta var de står i förhållande till andra företag, men också för att veta vart de vill och vart de är på väg. I och med att förändring är nödvändigt blir det allt vanligare för företag att ta hjälp utifrån  av  företag  som  är  experter  på  förändring.  Studier  visar  även  på  detta,  då  en trendförskjutning har skett de senaste 15 åren, där företag har blivit mer benägna att ta hjälp av  experter  gällande  förändringsarbete,  dels  för  att  minska  belastningen  på  den  egna personalen men också för att kunna fokusera på den ordinarie verksamheten. Transformator Design är en av dessa experter och deras önskan om att välja ut "de bästa" nyckeltalen, för förändring, med fokus på kunden, är grunden till detta examensarbete. Fortsättningsvis är målsättningen med studien att bidra med förståelse för hur företag, i allmänhet, bör arbeta med förändringsarbete Studien har, efter granskning av teori och tidigare empiriska studier, utfört intervjuer med de fem företagen SEB, Netsurvey, Telia, Ica och Skandia. Gemensamt för dessa företag är att de alla  bedrivit  förändringsarbete. Resultatet av  teorierna visar  på  att  det  inte  finns  någon generell patentlösning när det kommer till val av nyckeltal, utan att det varierar beroende på vilken typ av verksamhet som ett företag bedriver. Vid val av nyckeltal bör dock samtliga företag, oavsett verksamhet, välja ut sådana som speglar både verksamheten, medarbetarna och kunden. Detta eftersom kunden indirekt påverkas av en nöjd verksamhet med nöjda medarbetare.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography