Dissertations / Theses on the topic 'Transformatorer'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 50 dissertations / theses for your research on the topic 'Transformatorer.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Danielsson, Jonny. "Reläskydd för transformatorer : Funktioneroch Skyddsfilosofier." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-90323.
Full textProtection philosophies have been the same throughout the years. A good balance between reliability, selectivity, simplicity, speed and economy are required. How it is done is often quite individually and protection philosophies may differ somewhat between different engineers, and therefore there is no exact answer to how the optimal solution for a specific relay protection system should look like. More detailed studies on the features and comparisons have been made between the electromechanical overcurrent protection RRMJ 4 and the new numerical protection ABB REF 615. Both differential protections, the static RYDSA 20 and the numerical SPAD 346 has also been investigated and compared. The work has shown that the electromechanical and static relays guards were simple in its execution and trustworthy. The elderly protection tested still worked fine after 30-40 years of operation. As expected, it was the REF 615 that was significantly faster than its older counterpart RRMJ 4. What was less expected was that the static differential protection RYDSA 20 was about 10 ms faster than the numerical protection SPAD 346. The conclusion was that the speed and reliability have been improved with the numerical protections and more features are also built in. But with more features, they become more complex and also require more of the person who will make all the settings. Set correctly so has the numerical protections meant a great step forward. The older systems were simple, which is a big advantage, but do not outweigh the benefits of what the new numerical protections have meant.
Gustafsson, Henrik. "Jämförelse mellan Hexatransformator och konventionella transformatorer." Thesis, University West, Department of Technology, 2002. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-404.
Full textAssarsson, Fredrik, and Felix Nilsson. "Utredning av övertoners effekter på transformatorer." Thesis, Högskolan i Halmstad, Akademin för informationsteknologi, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-39706.
Full textThis thesis is a study of how one of Halmstad Energi och Miljö Nät AB’s transformers is affected by current harmonics. The study is mostly about how much the transformer's nominal power must be derated. The study shows the theory of both what is harmonics, how harmonics affect transformers and calculation models for derating transformers. The methods used and compared for the transformer power write-down are factor K, which is described in SS-EN 50464-3 and K-factor, which is described in ANSI / IEEE C57.100. In order to realistically investigate how the different standards affect the transformer, three cases have been tested. The mean effect of the harmonics over a month, based on collected measurement data. The maximum effect of the harmonics over a month, based on collected measurement data. The effects of harmonics if the harmonic levels increase in the future. The result of the study shows that in the cases based on measurement data the nominal power of the transformer should be reduced by about 6-17% for the K-factor method. For factor K, the figures are about 2.5-7.5%. However, the measurement data from all cases shows that the load rate of the tested transformer is far below the maximum impaired effect. If the amount of current harmonics would increase in the future, a write-down of 30% of the maximum effect is not unreasonable.
Enbom, Nils, and Faruk Kodzaga. "Omkonstruktion av lyftögla till ABB:s transformatorer." Thesis, Uppsala universitet, Industriell teknik, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-414647.
Full textFör att kunna förse större delar av världen med förnybar energi och tillfredsställa det ökande energibehovet krävs större och bättre transformatorer. Större transformatorer leder till problem med transport då många av järnvägarna i Sverige har en maximal bredd som inte får överstigas. För att kunna lyfta upp emot 600 ton och samtidigt hålla sig inom lastprofilen behövs innovativa lösningar på lyftöglorna som används för att lyfta transformatorerna. Syftet med denna studie är skapa ett koncept för en lyftögla som kan använda både syntetiska- och stålvajrar för att lyfta ABB:s transformatorer. Först fastställdes ett antal krav och önskemål för designen av lyftöglan. Dessa användes sedan vid konceptgenereringen. Med hjälp av Pughs matris jämfördes koncepten med varandra samt med den nuvarande lyftöglan som valdes som referens. De koncepten som hade högst poäng valdes för vidareutveckling. Koncepten konstruerades i CAD tillsammans med en representation av transformatorn som användes vid simuleringar i Creo. Slutligen valdes ett koncept för att vidareutvecklas. För att konceptet skulle klara alla krav som ställts utfördes rullande FEM analyser under studiens gång för att kunna testa olika dimensioner och designer av konceptet för att komma fram till ett så bra koncept som möjligt. Resultatet av studien blev att det slutvalda konceptet uppfyllde alla ställda krav samt de flesta önskemålen. Konceptets slutgiltiga dimensioner optimerades dessutom för att klara viktklasserna 30-, 40-, 70-, 100- och 150 ton som redovisas med hjälp av två tabeller i studiens resultatavsnitt. På grund av tidsbrist i studien kunde inte en prototyp av konceptet tillverkas.
Gustafsson, Stig. "Driftoptimering av effektkondensatorbatterier och transformatorer på mottagningsstationer." Thesis, Högskolan Väst, Institutionen för ingenjörsvetenskap, 2010. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-2543.
Full textThis report contains a study of power flows in Uddevalla Energi AB receiving stations and optimization of the operation control of its power capacitor batteries and transformers. For the past thirty years, Uddevalla Energi AB has employed power capacitor batteries almost all year around and these need soon to be replaced due to ageing. Uddevalla Energi Elnät AB has a need for new procedures for the operation control of the power capacitor batteries following new regulations introduced by Svenska Kraftnät and Vattenfall AB for reactive power flows on the grid. In the study of power capacitor batteries, there has been an investment calculation with three alternative purchase options. Option one is central phase compensation at the receiving station, option two is phase compensation at the receiving station supplemented with phase compensation at subscriber stations and option three is a local phase compensation at subscriber stations. The investment calculation shows that the second option: Central phase compensation supplemented with phase compensation at subscriber stations is the most favourable to implement. It has previously been found that, during certain times of the year, there has been a low load on some of the transformers of the receiving stations. It has never been investigated if it is profitable to turn off one of the transformer for the entire, or part of the year. In the investigation of the operation control of the transformers at the receiving stations, three alternatives have been considered. One alternative is that one transformer is in idle operation without load, the second alternative is that one transformer is completely turned off. The third alternative is to make no change. The study showed that the preferred alternative is to make no change, because the risks of turning off transformers are greater than the economic gain, that is approximately 101000 SEK.
Gerlitz, Cecilia. "Empirisk studie av nollföljdsimpedansen hos transformatorer utan deltalindning." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-234904.
Full textIn order to accurate calculate currents during unsymmetrical faults in the electric power grid information about all components positive, negative and zero sequence impedances are important. Transformers are one key component in the power grid and accurate information about sequence impedances for power transformers are therefore essential. However, to analytically derive the zero sequence impedance is extremely hard. Therefore are the transformers tested before they are connected. The Swedish TSO (Transmission System Operator), Svenska kraftnät,Svk, are responsible for operating and balancing the Swedish transmission grid. For Svk it is crucial that the grid is operated in a reliable and safe way so that the society always have available electricity at the same time as no persons working on the grid are exposed to unnecessary risks. Having accurate current calculations during unsymmetrical faults is one crucial part. Unfortunate, for some transformers in Svk area of responsibility the information about zero sequence impedance is missing and must therefore be estimated. This work propose, by applying a case study on a existing group of transformers (three limb design with no L}. windings), a method for estimating the zero sequence impedance. The aim of the the analysis is to investigate if there are any relationship between the zero sequence impedance and some more basic operating data for the transformers. From an initial literature study it was concluded that the following parameters would affect the zero sequence impedance: rated power and voltage, no-load power and currents and information about winding configuration, manufacture and production year. In the case study linear relationships was found based on a least square method and was tuned using a robust linear square method called Bisquare. The results showed that several of the tested quantities showed a growing trend when they were correlated with the zero sequence impedance. The no-load impedance was identified as one interesting quantity that was investigated further. The tested transformers were divided into different groups based on number of windings and winding confi- guration. In the next step the transformers were ordered based on rated power. New linear relationships were derived for every group and the final results were compared between the different transformer groups. The reliability of the proposed algorithm is dependent on the size of the tested transformer group and also on the data quality. The data quality was investigated by trying to identify transformer with abnormal values. The results showed that abnormal behaviour was very rare in the tested group of transformers. The results from the case study indicates that a relationship between the no-load impedance and the zero sequence impedance exists for the common types of transformers, the YNyn0, YNauto0 and YNyn0yn0. The results shows that these relationships differ depending on the rated power of the high voltage winding. The case study also concludes that it is possible to estimate a winding’s zero sequence impedance if the zero sequence impedance for a second winding is known as well as the rated voltage of the two windings. The presented relationships have all some uncertainty related to them, for some relationships the uncertainty is relatively high whereas for others it is very low. The relationship with the lowest uncertainty found was the function describing a winding’s zero sequence impedance as a function of another windings zero sequence impedance and the rated voltages
Weidemann, Stephan. "Handlingsplan för ägare av transformatorer med korrosiv olja." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-122436.
Full textSince the early 2000 a great number of transformers have broken down, without any apparent reason at first. The problem was identified to be an anti-oxidization-additive in the oil, dibenzyl disufide (DBDS), that had reacted with the copper in the windings. This gave rise to copper sulfide deposits on the isolating paper, which in turn reduced the isolating properties of the paper. A large number of studies have been completed to clarify what’s happening, why it’s happening and what can be done about it. The background for this thesis is that a 230MVA transformer broke down, despite the fact that the owner had taken the recommended precautions. This study will show that a number of factors, such as heat, Sulphur content and bad joints in the windings can accelerated the corrosion of copper and the formation of copper sulfide. The risks of a break-down can be reduced by adding Irgamet 39 at an early stage or by an oil change/desulphurization if the transformer is older. The already formed copper sulfide, on the other hand, cannot be removed and so an important first step is to fortify the electrical protection of the transformer by looking over the surge-arresters.
Al-Breihi, Mohammed. "Utveckling av laboration om trefastransformatorn : En studie om transformatorer." Thesis, KTH, Skolan för teknik och hälsa (STH), 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-166240.
Full textThis degree project was carried out on behalf of the unit for Computer and Electrical engineering at the School of Technology and Health, KTH. This study about transformers, their function and uses, the way they’re built, how the core and windings, which are the most important parts of a transformer, are made and what kind of materials are used to make them. Several types of transformers and their functions are described. A crucial part of the study has been to search for different ways to develop transformers to make them environmentally safer and to increase their life-span. As such this work describes different transformer oils, what advantages and disadvantages they have compared to mineral oils, what properties they have and in what way they’re less harmful for the environment. HVDC units transform high voltages from Alternating Current to Direct Current to lessen the resistive losses and energy losses which lead to a cleaner environment. The theory examination of the transformer is the basis for the formation of a lab for educational use, among others in a course about electrical power that’s included in Bachelor of Science in Electrical Engineering at KTH.
Dahlin, Carmen. "Empirisk bestämning av nollföljdsimpedans hos transformatorer med utdragen deltalindning." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-278507.
Full textHuvudändamålet med avhandlingen är att genom tillgänglig data, empiriskt bestämmakvoten mellan noll- och plusföljdsimpedansen hos olika transformatortyper med utdragen-lindning, d.v.s. när -lindning är belastad. Anledningar till att använda en -lindningkan t.ex. var för att tillgodose en specifik fasförskjutning i spänningen mellan primär- ochsekundärsidan, eller för att det är ekonomiskt vid hög ström och låg spänning. Avhandlingenbehandlar även beroende av lindningskopplarläge, transformatorkonstruktion ochkopplingsart (autokopplat och fullindat) och undersöker om variationer går att relatera tillfabrikat, typbeteckning, tillverkningsår, märkeffekt och märkspänning.Information om kvoten mellan noll- och plusföljdsimpedansen används för att t.ex. beräknafelströmmar, vilket är viktigt för att ställa in skyddssystem. En transformators sekvensimpedanserbestäms vanligen efter tillverkningen genom ett antal tester. Dock saknar ett antaltransformatorer i elnätet data om nollföljdsimpedansen och det är p.g.a. detta som den häravhandlingen genomförts, då nödvändiga prov inte kan genomföras när transformatorn äri drift.Datan har delats in i sex grupper: shuntreaktorer, tvålindningstransformatorer med en-lindning, trelindningstransformatorer med en -lindning, trelindningstransformatorermed två-lindningar, tvålindningstransformatorer med kortsluten Y-lindning och utan-lindning och trelindningstransformatorer med kortsluten Y-lindning och utan -lindning.För att analysera den tillgängliga datan har en algoritm skapats i MATLAB för att finnamöjliga korrelationer. Samband har modellerats linjärt och presenterats visuellt och numerisktmed tillhörande prediktionsintervall för att kunna användas i framtida nätberäkningar.Medelvärdet och konfidensintervallet av kvoten mellan noll- och plusföljdsimpedansen,samt kvoten mellan noll- och plusföljdsresistansen har beräknats för varje grupp, beroendepå det antalet kärnben transformatorn har.De viktigaste resultaten inkluderar medelvärdet (och konfidensintervallet) för kvoten mellannoll- och plusföljdsimpedansen, samt för kvoten mellan noll- och plusföljdsresistansenför fem- och trebenta transformatorer. Vidare upptäcktes korrelationer för kvoten mellannoll- och plusföljdsimpedansen och lindningskopplarläget. Dessutom observerades attkvoten mellan noll- och plusföljdsresistansen har stigit med tiden, medan kvoten mellannoll- och plusföljdsresistansen har avtagit. Detta gäller framförallt tvålindningstransformatorermed en -lindning. Dessutom upptäcktes en korrelation mellan nollföljdsresistansenoch plusföljdsimpedansen där datapunkterna delat upp sig i två grupper, där den enagruppen samlats runt fembenta transformatorer. En möjlig förklaring är att dessa transformatorerkan vara utrustade med magnetiska shuntar, men detta gick inte att undersökavidare i denna studie.
Almqvist, Gunilla. "Lathund för val av förband mellan transformator och ställverk." Thesis, University West, Department of Technology, 2002. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-352.
Full textGolmohammadi, Behnam. "Användning av programvaran Templife för analys av överbelastbarheten hos ett urval av Vattenfall Västnäts krafttransformatorer." Thesis, University West, Department of Technology, Mathematics and Computer Science, 2004. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-405.
Full textVarg, Torun, and Erica Oberholtzer. "Brandrisker och skyddshöjande brandtekniska åtgärder för kabelutrymmen, lokaler för växelhuvudströmscentral och transformatorer inom vattenkraftverk." Thesis, Luleå tekniska universitet, Byggkonstruktion och brand, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-77241.
Full textToday's society is dependent on electricity, from getting clean water in the faucet to being able to put fuel in the car electricity is required. Hydroelectric power plants account for almost half of today's production of electricity, which means that hydropower is a vital factor for the community to function. From an environmental perspective, hydropower is considered more environmentally friendly than electricity produced from fossil fuels. Since hydroelectric power plants play a big role in society makes it very important to prevent possible accidents and hold-ups in production, such as a fire. Fires have occurred at hydropower plants around the world. Colorado is an example where the fire started in the flammable material that was being used in a tunnel at the hydropower plant. This resulted in a fire where several workers were trapped in a tunnel underground, all workers died since there was only one escape route. In hydropower stations located underground, it is common that there is only one escape route. The accident demonstrates the complexity that exists in the dimensioning of hydropower stations underground. The purpose and goal of this project has been to identify fire risks at two hydropower plants and how to minimize and prevent them. In order to achieve the project's goals, a literature study has been conducted to provide an understanding for the problems that may arise. A risk investigation was also conducted at the hydropower plants to see what they look like in the reality. A computer simulation has also been made to give an idea of the smoke spread. This computer simulation has been performed using the Fire Dynamics Simulator (FDS). The literature study showed, through statistics from MSB's database IDA, that transformer fires are one of the biggest risks in underground facilities. During the visit to Messaure, a hydroelectric power plant, only the local transformers were placed below the ground. These local transformers were of a dry-transformer type, which results in a smaller fire hazard. Previously, there were also other transformers underground, but these are moved above ground to minimize the fire hazard. Unlike Messaure, Akkat's, a hydroelectric power plant, transformer was placed underground in a separate transformer hall, which is a separate fire cell. The entrance to this was directly adjacent to the access tunnel which is also used for evacuation. To investigate how much a fire in the transformer hall would affect the evacuation, this space was chosen for an FDS analysis. The conclusion that can be drawn is that if the door should be left open, a fire in the transformer would have a major negative impact on the evacuation. Smoke quickly streamed into the access tunnel, which has an effect on all evacuation. The door should always be closed . However, there is no automatic door closer, which can result in the door being left open. A cost-effective improvement would be to install a door closer, which could save lives.
Bergdahl, Johan, and Andreas Karlsson. "Kraftvärmeverk 1 Egenförbrukning : En studie över frånkopplingsmöjligheter." Thesis, Linköping University, Department of Management and Engineering, 2007. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-10603.
Full textRapporten beskriver hur vi gått tillväga för att lösa uppgiften som var att bestämma om det går att stänga av några transformatorer under sommarrevisionerna när man inte producerar någon elektricitet. Den tar även upp hur förbrukad el förhåller sig till förbrukad effekt vid vissa driftfall, samt även hur förbrukningen ser ut kontra producerad över året.
Genom kartläggande av de stora effektförbrukarna, och bestämma under vilka driftfall de används, har vi kunnat konstatera att det skulle krävas ett mycket omfattande omkopplingsarbete för att kunna koppla ifrån en transformator. Vidare undersökte vi de faktiska tomgångskostnaderna för själva transformatorerna och kom fram till att dessa är väldigt små i sammanhanget.
Många problem uppenbarade sig under arbetets gång ju mer information som intogs, exempel på det är just att många komponenter till de olika pannorna är fördelade över flera transformatorer och en annan orsak är att centraler för lampor och dylikt är kopplade i olika omfattning till de olika transformatorerna, vilket gör att om man slog av dessa skulle de som jobbar under revisionerna få arbeta i mörker. Slutsatsen blir att det är svårt att hitta enkla sätt att spara energi, som att slå av och på en transformator, och att man kanske borde titta mer på enskilda komponenter.
Härjebäck, Anders. "Avfallshantering : På Härjeåns Nät AB, med fokus på energi- och materialåtervinning." Thesis, Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-16073.
Full textDetta examensarbete har utförts vid Mälardalens Högskola i Västerås och Härjeåns Nät AB, främst i Sveg. Härjeåns Nät AB är ett elnätsföretag som står för eldistributionen i bl.a. Härjedalens kommun, Ånge kommun, Ragunda kommun och Bräcke kommun. Vid underhåll och rasering av el- och bredbandsnät uppkommer en hel del avfall. Syftet med detta examensarbete är att lägga fram förslag på hantering av avfallet. Målet är att alla Härjeåns arbetsplatser ska ha likvärdig hantering av avfallet och en översikt om hur man ska hantera de olika avfallen. Arbetet ska bedrivas som ett steg mot ISO-certifieringarna SS-EN ISO 9001:2008 för kvalitet och SS-EN ISO 14001:2004 för miljö. Företag är skyldiga att känna till vilka lagar och regler som gäller för att bedriva verksamheten och avfallet som genereras som följd av denna. Tyngden i arbetet ligger på hanteringsförslag, vilket har lett till att nulägesbeskrivningen hållits kort med desto mer tid för informationssökning av alla lagar och förordningar som berör Härjeåns avfallshantering. Dagsläget på linjekontoret i Sveg innebär att mycket avfall läggs i en osorterad container som ger upphov till höga kostnader för företaget. Impregnerade stolpar saknar god hantering och farligt avfall behöver konkreta riktlinjer att följa. Metaller sorteras bra men kan behöva en översyn. Skyltning finns men är gammal och bristfällig. Avfall förekommer med många olika egenskaper och hanteringen varierar beroende på vilken typ av avfall det handlar om, geografiskt läge samt hur välsorterat det är. Att sortera material rätt minskar kostnader för omhändertagande och kan istället generera en ersättning, till exempel att sortera järn och metaller och sälja dessa. De styrmedel som främst berör avfallshantering är Miljöbalken, Avfallsförordningen, Naturvårdsverkets författningssamling 2004:10 och kommunala direktiv. Innehållet i dessa författningar granskas för material som uppkommer inom elnätsbranschen. Vid uppkomst av farligt avfall är företaget skyldigt att ha rätt kunskaper om avfallet och hur det påverkar hälsa och miljö, regler för hantering och klassning, dokumentering samt förebygga uppkomsten. Allt farligt avfall kräver en entreprenör som har särskilt tillstånd att transportera och/eller förvara det från Länsstyrelsen. Övrigt avfall bör transporteras och omhändertas på ett miljöriktigt sätt med godkända och medvetna entreprenörer. Förslag på hantering av avfallet läggs fram, krav på entreprenörer och mottagningsstationer föreslås, vilka partitioner som är nödvändiga, vilka lagar som måste följas och vilka helhetslösningar som finns.
Nilsen, Ida. "Investerings- och byggnationsanalys av integrerade och fristående strömtransformatorer i Ellevios regionnät." Thesis, Högskolan Väst, Avdelningen för Industriell ekonomi, Elektro- och Maskinteknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-12388.
Full textThe purpose of this diploma thesis is to conduct a technical and economic investigation of two construction methods of current transformers in substations. In the report the power transformer, the instrument transformer, the current and voltage transformers are presented. The power transformer is one of the most important components in the power grid, whose main task is to transform electricity from one voltage level to another. The instrument transformers are used to separate high voltage circuits from the measuring instruments. The voltage transformers task is to transform the primary voltages into secondary measurement voltages, and the current transformer main task is to convert primary currents to smaller, standardized secondary currents to get less and more manageable currents that are easier to measure. In the thesis, pros and cons with the independent and integrated current transformers are compared in Ellevio's regional network. Two financial calculations are presented and a requirement study about Ellevio's current requirements for measurement with instrument transformers in the regional network is submitted. This has been through extensive surveying and interviews with expert stakeholders in the area. The theoretical and economic investigation shows that the investment cost of the integrated current transformer is considerably lower and that it is space saving and that it´s more complicated to correct possible errors on this type of current transformer.
Hellborg, Jonatan. "Analys av industrinät med spänning 7,8 kV." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-159776.
Full textThe Bofors industrial power grid in Karlskoga is aged and currently operating with a non-standardized voltage level. This analysis has been done in collaboration with “Karlskoga energi och miljö AB” with the purpose of determining what needs to be replaced, added or removed in order to facilitate an increase in voltage from today’s level (7.8 kV) to the same level as the rest of the distribution grid (10 kV). In addition to this also produce the framework for a plan on how this voltage increase is to be accomplished, as well a determining how much the losses can be reduced and how much of an economic impact this has. The results of the analysis are that all of the 39 distribution transformers currently in use must be replaced in order to not have these break down. The cables in use, however, will be fine due to them being constructed for 12 kV. The framework produced determines that the best course of action is for the company to build a new grid on top of the old one, with a voltage of 10 kV and allow existing customers to connect to this grid during a set time period. In regards of the losses in the grid, a potentially large saving can be made. Approximately 415 708 SEK per year, calculated with an energy price of 0.85 SEK per kWh, of which the no-load losses of the transformers is the majority. The calculated cable losses were almost non-existing. All this proves the benefits of performing this voltage increase, and the construction required. Initially there is quite a large investment needed from the company, but the benefits are large enough that It would be irresponsible to not go through with the voltage increase. By doing this the company gets a better grid, not just better dimensioned but also a much more reliable grid with shorter delivery times on for example transformers. This analysis has not gone into depth regarding the two hydropower plants connected to the grid.
Fältström, Mattias, and Berg Joakim Nelson. "Förstudie av fasningssystem : Till dieselgeneratorer på Forsmark 1." Thesis, Uppsala universitet, Elektricitetslära, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-297937.
Full textIt is well known that nuclear electricity production is one of the types of production with the highest demands on security. There are multiple security systems, and one consists of diesel generators. The diesel generators need a synchronization system to be able to confirm safe starting operation. This master thesis investigates the synchronization system and associated measuring systems to the diesel generators, with the purpose of advising Forsmarks Kraftgrupp AB on things that could be changed concerning transformer- and synchronization configuration at Forsmark 1. An improved solution to the existing synchronization system with its associated measurement equipment was found by studying documentation, performing measurements on the system, contacting suppliers, performing simulations and testing the instrument transformers. The results that emerged from the feasibility study have made suggestions for either possible reconstruction or reconfiguration of individual parts of the existing synchronization system. The recommendation in case of redevelopment is to introduce a three-phase measurment system compatible with the synchronization equipment with a separate three-phase measuring circuit. If instead, the existing synchronization equipment is preserved and an individual part replaced, it is recommended to reconfigure the instrument transformers to delta-Y from the present Yn-Yn connection. If the system will be rebuilt or reconfigured, recommendations for confirmatory testing of any modifications have been developed.
Scheutz, Godin Axel. "Tillståndsbedömning av krafttransformatorer i stamnätet : En rekommendation av diagnostiska mättekniker." Thesis, KTH, Skolan för elektro- och systemteknik (EES), 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-187813.
Full textA transformer fault could affect the reliability of a power system and have serious economic consequences. Therefore there is an increasing demand among electrical utilities to assess the actual condition of their transformers and hence detect faults before they occur. Condition monitoring has the potential to reduce operating costs and improve the reliability of operation. The aim of this master thesis has been to investigate available diagnostic measurement techniques that can assess the condition of power transformers. Transformer failure statistics has been studied in order to understand what different faults that can occur and to which extent they appear. The consequences of different faults have been investigated. Available measurement techniques were coupled with what faults they can detect. The diagnostic measurement techniques have also been compared in regard to cost, lifetime and accuracy. The comparison resulted in a recommendation over which measurement techniques that are most suitable for the Swedish transmission system operator, Svenska Kraftnät. There is a need among electrical utilities of economic and technical justifications for optimal investment and maintenance decisions. One available asset management technique that enables this is the health index. A health index is a tool that combines available measurement data from operating observations, field inspections and laboratory testing into an objective and quantitative index. The index provides information about the overall condition of an asset. A case study has been conducted where an available health index was used to estimate the condition of three transformers. The results indicate that the health index presents an efficient way to represent the condition of transformers. The disadvantage of the used index is that it implies a good condition even when the quality of the transformer insulation paper is poor. An alternative health index is therefore proposed where the paper insulation quality has a larger impact on the index.
Goßner, Thomas. "Effizientes Design von Planar-Transformatoren." kostenfrei, 2010. https://mediatum2.ub.tum.de/node?id=823188.
Full textAtaniyazov, Ataniyaz. "Transformatorers tekniska och ekonomiska livslängd." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-96594.
Full textThis thesis is performed at WSP in Skellefteå, specializing in Rönnskär Education in Skelleftehamn. Rönnskär’s construction began by Boliden AB in 1928 and it was ready for production in 1930. It produces copper, lead, zinc clinker, gold and silver. In 2010 Rönnskär produced 190000 tons of copper and in 2013 it produced 206 000 tons. Current number of employees is 866. The electricity supply of the industrial area of Rönnskär is in very high priority and transformer failures leading to lengthy downtime and expensive repairs. Power transformers must have high operational availability transformers which purchases for production must be robust. This is a comparative study between dry type and oil insulated transformers which summarized in form of recommendation for the future purchases. The work will highlight the parameters of operational availability and operational safety make calculations for rated short time currents and losses in transformers based on manufacturers data. The aim of this thesis is to compare various parameters of dry and oil immersed transformers from different manufacturers summarized in a comparison table according to the apparent power and voltage which shows the difference between various types of transformers. This work is primarily based on the theory of transformers and at the same time on continuous dialogue with the client and the transformer manufacturer. The recommendations should be viewed as a preliminary study, a deeper analysis and further investigation is required when purchasing transformers, depending on the circumstances and the conditions. An economic analysis has not been performed because of the limited information. Keyword for this study is AOS: Availability and Operational Safety.
Meinert, Michael. "Hochtemperatursupraleitende Transformatoren für künftige Schienenfahrzeuge /." Aachen : Shaker, 2007. http://bvbr.bib-bvb.de:8991/F?func=service&doc_library=BVB01&doc_number=016499393&line_number=0001&func_code=DB_RECORDS&service_type=MEDIA.
Full textBlėdis, Tomas. "Sausų galios transformatorių panaudojimo tyrimas." Master's thesis, Lithuanian Academic Libraries Network (LABT), 2004. http://vddb.library.lt/obj/LT-eLABa-0001:E.02~2004~D_20040616_143628-98619.
Full textMeinert, Michael [Verfasser]. "Hochtemperatursupraleitende Transformatoren für künftige Schienenfahrzeuge / Michael Meinert." Aachen : Shaker, 2007. http://d-nb.info/1166512118/34.
Full textMousavi, Takami Kourosh. "Process Control and Simulation of Ferromagnetic Strip in the Power Transformers and Electrical Machines Applications : Electric power systems." Doctoral thesis, Västerås : School of Sustainable Development of Sociaty and Technology, Mälardalen University, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-6648.
Full textFreshwater, Dawn. "Transformatory learning in nurse education." Thesis, University of Nottingham, 1998. http://eprints.nottingham.ac.uk/11580/.
Full textAndersson, Carl Fredrik. "50 kVA eller 100 kVA : En teknisk och ekonomisk jämförelse av distributionstransformatorer." Thesis, Högskolan Väst, Institutionen för ingenjörsvetenskap, 2010. http://urn.kb.se/resolve?urn=urn:nbn:se:hv:diva-2730.
Full textGogoulou, Evangelina. "Using Bidirectional Encoder Representations from Transformers for Conversational Machine Comprehension." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-265656.
Full textBidirectional Encoder Representations from Transformers (BERT) är en nyligen föreslagen språkrepresentationsmodell, utformad för att förträna djupa dubbelriktade representationer, med målet att extrahera kontextkänsliga särdrag från en inmatningstext [1]. Ett utmanande problem inom området naturligtspråkbehandling är konversationsförståelse (förkortat CMC). Givet en bakgrundstext, en fråga och konversationshistoriken ska systemet förutsäga vilken del av bakgrundstexten som utgör svaret på frågan. Den viktigaste utmaningen i denna uppgift är hur man effektivt kan kodifiera konversationshistoriken i förutsägelsen av nästa svar. I detta examensarbete undersöker vi användningen av BERT-språkmodellen för CMC-uppgiften. Vi föreslår en ny arkitektur med namnet BERT-CMC med BERT-modellen som bas. Denna arkitektur innehåller en ny modul för kodning av konversationshistoriken, inspirerad av Transformer-XL-modellen [2]. Den här modulen tjänar minnets roll under hela konversationen. Den föreslagna modellen tränas och utvärderas på en datamängd för samtalsfrågesvar (CoQA) [3]. Vår hypotes är att BERT-CMC-modellen effektivt kommer att lära sig det underliggande sammanhanget för konversationen, vilket leder till bättre resultat än basmodellen som har föreslagits för CoQA. Våra resultat av utvärdering av BERT-CMC på CoQA-datasetet visar att modellen fungerar dåligt (44.7% F1 resultat), jämfört med CoQAbasmodellen (66.2% F1 resultat). För att bättre kunna förklara modellen utför vi också en kvalitativ analys av modellbeteendet i frågor med olika språkliga fenomen, t.ex. koreferens, pragmatiska resonemang. Dessutom motiverar vi de kritiska designvalen som gjorts genom att utföra en ablationsstudie av effekten av dessa val på modellens prestanda. Resultaten tyder på att finjustering av BERT-lager ökar modellens prestanda. Dessutom visas att ökning av antalet extra lager ovanpå BERT leder till större konversationsminne.
Dumke, Knut. "Untersuchungen an einer Esterflüssigkeit als Isolierstoff für Transformatoren /." Düsseldorf : VDI-Verl, 1999. http://www.gbv.de/dms/bs/toc/270224106.pdf.
Full textDragana, Naumović Vuković. "Prilog savremenom etaloniranju strujnih mernih transformatora." Phd thesis, Univerzitet u Novom Sadu, Fakultet tehničkih nauka u Novom Sadu, 2018. https://www.cris.uns.ac.rs/record.jsf?recordId=107383&source=NDLTD&language=en.
Full textThe dissertation presents the concept, its realisation and verification of the new methodof simultaneous comparison of the current transformers by two different measuringapparatus. It is shown by searching the literature, that this method has not been usedbefore. In this dissertation different measuring methods for testing and calibration ofcurrent transformers, with their different measuring capabilities are presented. Most ofthem have been used in recent practice. Furthermore, the experimental verification ofnew simultaneous calibration method is presented. For this reason some measuringapparatus based on different measuring methods were used. Conducted research andexperimental results confirmed a number of advantages of this calibration method.Detailed analysis of the components of the uncertainty of measurements shown thatusing simultaneous method uncertainty of measurements have been improvedcomparing to method with two individual calibration by different apparatus. In that casesome of the measuring uncertainty components can be neglected. The most significantis component caused by variation of referent current and component caused by variationof burden. The research has also showed that simultaneous method can be used forcalibration of measuring apparatus for current transformer accuracy testing and theirinter-comparisons. The ways of calibration of apparatus for current transformer accuracytesting are considered and presented, through concrete examples realized in practice.A high-accuracy comparison of two NRC (National Research Council Canada)calibration systems were carried out by new simultaneous method. One measuringsystem is developed at Electrical Engineering institute Nicola Tesla, Belgrade.Accordingly the advantage of simultaneous method applied at the primary metrology ofcurrent transformer is verified.
Berger, André [Verfasser], and M. [Akademischer Betreuer] Noe. "Entwicklung supraleitender, strombegrenzender Transformatoren / André Berger ; Betreuer: M. Noe." Karlsruhe : KIT Scientific Publishing, 2011. http://d-nb.info/1185581553/34.
Full textSemberg, Tobias. "Byggnation och mätning av kabellindad variabel transformator." Thesis, Uppsala universitet, Institutionen för teknikvetenskaper, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-162793.
Full textMutaliev, Mohammed, and Ibrahim Almimar. "Optimering av en chattbot för det svenska språket." Thesis, KTH, Hälsoinformatik och logistik, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-296616.
Full textChatbot developers at Softronic currently use the Rasa framework and its default components for processing user input. This is problematic as the default components are not optimized for the Swedish language. Following this an evaluation of all Rasa components was requested with the purpose of identifying the most favorable components to maximize classification accuracy. In this thesis, several Rasa pipelines were developed and compared with different components for tokenization, feature extraction and classification. The results of the tokenization components showed that Rasa's WhitespaceTokenizer surpassed both SpacyTokenizer and StanzaTokenizer. For feature extraction, CountVectorsFeaturizer, LanguageModelFeaturizer (with the LaBSE model) and FastTextFeaturizer (with the official fastText model trained on Swedish Wikipedia) were the most optimal components. The classifier that generally performed best was DIETClassifier, but there were several occasions where SklearnIntentClassifier surpassed it. This work resulted in several pipelines that exceeded Rasa’s standard pipeline. Of these pipelines, two performed best. The first pipeline implemented the components WhitespaceTokenizer, CountVectorsFeaturizer, FastTextFeaturizer (with the official fastText model trained on Swedish Wikipedia) and DIETClassifier with a classification accuracy of 91% (F1 score). The other pipeline implemented the components WhitespaceTokenizer, LanguageModelFeaturizer (with the LaBSE model) and SklearnIntentClassifier with a classification accuracy of 91.5% (F1 score).
Holm, Henrik. "Bidirectional Encoder Representations from Transformers (BERT) for Question Answering in the Telecom Domain. : Adapting a BERT-like language model to the telecom domain using the ELECTRA pre-training approach." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-301313.
Full textDubbelriktade språkmodeller som BERT har på senare år nått stora framgångar inom språkteknologiområdet. Flertalet vidareutvecklingar av BERT har tagits fram, bland andra ELECTRA, vars nyskapande diskriminativa träningsprocess förkortar träningstiden. Majoriteten av forskningen inom området utförs på data från den allmänna domänen. Med andra ord finns det utrymme för kunskapsbildning inom domäner med områdesspecifikt språk. I detta arbete utforskas metoder för att anpassa en dubbelriktad språkmodell till telekomdomänen. För att säkerställa hög effektivitet i förträningsstadiet används ELECTRA-modellen. Uppnådd prestanda i måldomänen mäts med hjälp av ett frågebesvaringsdataset för telekom-området. Tre metoder för domänanpassning undersöks: (1) fortsatt förträning på text från telekom-området av en modell förtränad på den allmänna domänen; (2) förträning från grunden på telekom-text; samt (3) förträning från grunden på en kombination av text från telekom-området och den allmänna domänen. Experimenten visar att metod 1 är både kostnadseffektiv och fördelaktig ur ett prestanda-perspektiv. Redan efter kort fortsatt förträning kan tydliga förbättringar inom frågebesvaring inom måldomänen urskiljas, samtidigt som generaliserbarhet kvarhålls. Tillvägagångssätt 2 uppvisar högst prestanda inom måldomänen, om än med markant sämre förmåga att generalisera. Metod 3 kombinerar fördelarna från de tidigare två metoderna genom hög prestanda dels inom måldomänen, dels inom den allmänna domänen. Samtidigt tillåter metoden användandet av ett tokenizer-vokabulär väl anpassat för båda domäner. Sammanfattningsvis bestäms en domänanpassningsmetods lämplighet av den respektive situationen och datan som tillhandahålls, samt de tillgängliga beräkningsresurserna. Resultaten påvisar de tydliga vinningar som domänanpassning kan ge upphov till, även då frågebesvaringsuppgiften lärs genom träning på ett dataset hämtat ur den allmänna domänen på grund av otillräckliga mängder frågebesvaringsdata inom måldomänen.
Zorin, Aleksej. "Akmenės transformatorių pastotės elektros tinklo patikimumo didinimo priemonės." Master's thesis, Lithuanian Academic Libraries Network (LABT), 2013. http://vddb.laba.lt/obj/LT-eLABa-0001:E.02~2013~D_20130618_154914-38953.
Full textThis paper deals with Akmenės transformer substation power supply failure, and increase the robustness of the problem based on the scientific literature and practical experience summary. Setting Akmenės transformer substation power supply 0.4-10 kV line number of faults, the number of disconnection, disconnection times and causes. Calculate Akmenės transformer substation power supply reliability indicators, mostly perishable standby power lines and forced inactivity rates and the probability of failure and operational within 12 months.
Dejana, Herceg. "Modelovanje mernih transformatora bez jezgra sa feromagnetskim oklopom." Phd thesis, Univerzitet u Novom Sadu, Fakultet tehničkih nauka u Novom Sadu, 2016. https://www.cris.uns.ac.rs/record.jsf?recordId=96158&source=NDLTD&language=en.
Full textIn this thesis a method for examining the effects of shielding on a corelessmeasuring transformer from the standpoint of transformer linearity and EMradiation shielding is developed. A parametric model of the shield and thecoreless measuring transformer is constructed. Measurements of magneticproperties of ferromagnetic materials were performed; a new analytical modelof hysteresis is developed; magnetization curves and permeability of thematerials are determined. Based on numerical and experimental results, andusing the defined criterion, the analysis of shielding quality of the consideredshield types was performed.
Schwarzmann, Holger [Verfasser], and Heiner [Akademischer Betreuer] Ryssel. "Piezoelektrische Transformatoren zur Ansteuerung von Leistungsschaltern / Holger Schwarzmann. Betreuer: Heiner Ryssel." Erlangen : Universitätsbibliothek der Universität Erlangen-Nürnberg, 2012. http://d-nb.info/1021259748/34.
Full textHoffmann, Holger [Verfasser]. "Elektronischer Transformator für Hochleistungs-Traktionssysteme am Wechselspannungsnetz / Holger Hoffmann." München : Verlag Dr. Hut, 2012. http://d-nb.info/1029400326/34.
Full textBratt, Adam, and Hernekoski José Luis Jimenez. "Övertoner från UPS i transformator : Lokalisering och möjliga lösningar." Thesis, Högskolan i Borås, Akademin för textil, teknik och ekonomi, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:hb:diva-23434.
Full textThe purpose of this report is to map and analyse the existing harmonics in connection with one of AstraZeneca´s Uninterruptible Power Supply (UPS) stations. Additionally, give a general insight of the harmonic distortion’s characteristics accompanied by their consequences and solutions. The analysis was carried out using two different instruments, an ultrasound microphone and a network analyser. The ultrasound microphone measures sound frequencies in the air which can be associated with the vibrations produced by the harmonics in the transformer. The network analyser was used with the intent to measure the harmonic distortions directly on the powerline in order to give a complete picture of the three phase’s waveform. The decision to use two different instruments was to achieve a twofold confirmation of the present harmonics. In the case of correlation between the two. The results showed the presence of 2nd, 5th, 7th, 11th and 13th harmonics in the current’s distortion. These were measured in a point between the transformer before the UPS and the UPS itself. The source of the harmonic distortion is the 6-pulse rectifier inside the UPS. The harmonic distortion found inside the voltage showed no sign of exceeding regular harmonic distortion levels, which is a result of the measurements taking place on the incoming line of the UPS. After the UPS, the measurements showed greater harmonics than the measurement before the UPS. These harmonics included both even and odd going from the 2nd to 7th order. The cause seems to be the inverter’s switching of the batteries DC-voltage together with the pulse width modulation (PWM)-technology. The ultrasound microphones ability proved to be less adapted for this purpose in comparison to the network analyser since it did not pick up the strongest harmonics showed by the network analyser. The network analyser proved to be the key instrument for measuring the harmonics associated with the 6-pulsebridge, which exclusively can be pointed out as belonging to the rectifier in the UPS station. The network analyser also traced the tracks left by the inverter after the UPS. The consequences caused by the harmonic distortion spawns in the shape of excessive wear, unnecessary energy losses and heat increase in power lines and components. The solutions for this matter are various types of filters or reconstruction of components. These actions are not deemed as an obvious choice from economic standpoint due to the low estimated damage caused by the harmonics.
Voss, Stephan. "Semianalytische Modellierung elektrischer Ersatzschaltbilder für drahtgewickelte Spulen und Transformatoren in der Leistungselektronik." [S.l.] : [s.n.], 2006. http://deposit.ddb.de/cgi-bin/dokserv?idn=980372631.
Full textWenzel, Dirk. "Teilentladungsmessungen an Transformatoren im Netz mit Verfahren der digitalen Signalverarbeitung und Mustererkennung /." Düsseldorf : VDI-Verl, 1998. http://www.gbv.de/dms/bs/toc/252628284.pdf.
Full textNogerius, David. "Dimensionering av hjälptransformator." Thesis, Uppsala universitet, Nanoteknologi och funktionella material, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-191874.
Full textFransson, David. "Projektering av elkraftanläggning för fläktprov : dimensionering av transformator, kablar mm." Thesis, Växjö University, School of Mathematics and Systems Engineering, 2006. http://urn.kb.se/resolve?urn=urn:nbn:se:vxu:diva-808.
Full textFläkt Woods har ett fläktlab i Växjö där man utför kund och leveransprover av axiella fläktar.
Befintlig anläggning är i dag bristfällig när det gäller driftsäkerhet och personsäkerhet. Även möjligheten att köra varvtalsreglerat är idag begränsad.
Uppgiften är att projektera en ny anläggning omfattande en ny jordkabel, mellan- och lågspänningsställverk, transformatorer, kopplingsutrustningar och frekvensomriktare.
Magnusson, Lisa. "DESIGN IMPROVEMENTS OF DISTRIBUTION TRANSFORMERS : How to improve conditions of transportation in Vietnam." Thesis, Högskolan i Skövde, Institutionen för ingenjörsvetenskap, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:his:diva-10500.
Full textInternationella företag vill idag flytta sin produktion till utvecklingsländer i Asien. Deras produkter vars design har utvecklats i Europa är därmed inte alltid anpassade till transport- och tillverkningsförhållanden som finns i tillverkningslandet. Konsekvensen blir mindre kvalitativa produkter. Ett exempel på detta problem är distributionstransformatorer från ABB Vietnam som skadas under vägtransporter pga. dåliga vägar, ett problem som är omärkbart i Europa. Syftet med projektet var därför att analysera och utveckla designen av distributionstransformatorer, för ABB Vietnam, så att de bättre klarar av de svåra vägtransporterna. Detta examensarbete inom Integrerad Produktutveckling följer den allmänna designprocessen typiskt för produktutveckling och består av fyra faser som inkluderar Utforskning (av det vagt definierade problemområdet), Generering (av koncept), Utvärdering (av designförslag) och Kommunicering (av det slutgiltiga designförslaget). Metoder som litteraturstudier och empiriska undersökningar (observationer och intervjuer) utfördes på ABB Vietnam, i fabriken som ligger i Hanoi. Därifrån uppdagades information om problemområdet och en översikt över produktionen av ABB transformatorer. I studien framkom att det underliggande problemet berodde på en kombination av produktens struktur och landets infrastruktur t.ex. extrema vägförhållanden, lägre standard för transportmedel, etc. För att systematiskt skapa nya idéer implementerades diverse designmetoder, för att utveckla och värdera ett antal koncept. Det slutliga designkonceptet som valdes simulerades med avseende på verkliga transportförhållanden för att verifiera att konceptet kommer att motstå dessa påkänningar. Konceptet kan förbättras och optimeras ytterligare. Resultatet av studien visade att designers kan bidra till förbättringar och öka kvaliteten på produkter genom att förstå förhållanden i tillverkningslandet. Studien syftar till att upplysa vad de som arbetar med produktutveckling ska tänka på när de designar för transport och den kan användas som ett praktiskt exempel för liknande problem. Det slutliga designkonceptet är en extra stödram fäst på transformatorn för att öka transformatorns hållbarhet och förbättra kvaliteten - särskilt under extrema vägförhållanden.
Al-Yakoubi, Murad, and Elias Roham. "Underhåll och övervakning av distributionstransformatorer." Thesis, Linnéuniversitetet, Institutionen för datavetenskap, fysik och matematik, DFM, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-30749.
Full textWästljung, Martin. "Ny stamstation i Yttermalung för anslutning av vindkraft : Nätstudie av olika utföranden i normal- och reservdrift." Thesis, Uppsala universitet, Elektricitetslära, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-226929.
Full textHollinshead, Sophie. "Transformatory landscapes : spaces of health, reform and education on the Lincolnshire coast." Thesis, University of Nottingham, 2016. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.716673.
Full textBeringer, Sebastian [Verfasser]. "Prozessentwicklung zur Fertigung von substratlosen Mikrosystemen am Beispiel eines Mikro-Transformators / Sebastian Beringer." Garbsen : TEWISS - Technik und Wissen GmbH, 2021. http://d-nb.info/1228009910/34.
Full textGiorgis, Stavros. "Evaluation of Approaches for Representation and Sentiment of Customer Reviews." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-291214.
Full textKlassificeringen av attityd och känsloläge i kundrecensioner är en tillämpning med praktiskt värde för flera företag i marknadsanalysbranschen. Aktuell forskning i språkteknologi har etablerat vektorrum som standardrepresentation för ord, fraser och yttranden, så kallade embeddings. Denna uppsats utvärderar den senaste tidens mest framgångsrika textrepresentationsmodeller jämfört med mer traditionella vektorrum. Utvärdering görs genom att jämföra automatiska analyser med mänskliga bedömningar för kundrecensioner av varierande längd från olika domäner tillhandahållna av ett textanalysföretag. Inom ramen för studien har olika testmängder jämförts och olika sätt att modifera en språkmodells klassficering utan om träning. Alla modeller har också jämförts med avseende på resurs- och tidsåtgång för träning för att hjälpa uppdragsgivaren fatta beslut om vilken teknik som utgör den mest ändamålsenliga utvecklingsvägen för dess driftsatta system.
Molina, Gómez Andrea. "Improved planning of wind farms using dynamic transformer rating." Thesis, KTH, Skolan för elektroteknik och datavetenskap (EECS), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-287175.
Full textPå grund av ökningen av efterfrågan av elektricitet och förnybara energin, elförsörgingsföretag måste förbättras och elnätets infrastruktur måste optimeras. Grundläggande komponenter i elnätet är transformatorer, som är designade konservativt efter en statisk märkeffekt. Laster och vädret ändras dock kontinuerligt, detta betyder att transformatorer inte används på de mest effektiva sätten. Av denna anledning har en ny teknik utvecklats: Dynamisk lastbarhet hos transformatorer (DTR). Genom att applicera DTR, gör det möjligt att belasta en transformator högre än märkdata utan att påverka den förväntade livslängden. Detta projekt går ett steg längre och använder DTR för kort och lång sikts vindkraftparkplaneringar. Den optimala vindkraftparken är designad genom att använda DLT på krafttransformatorn för vindkraftsparken. Optimeringen utförst med hjälp av Mixed-Integer Linear programming (MILP) modell. Gällande transformatorns termiska analys, så valdes den linjäriserade toppoljemodellen av IEEE Clause 7. Modellen var utförd för fyra olika krafttransformatorer: 63 MVA, 100 MVA, 200 MVA och 400 MVA. Resultatet blev att nettonuvärdet för investeringen och kapaciteten av vindkraftsparken ökade linjärt med avseende på storleken på transformatorn. En känslighetsanalys var utförd genom att ändra vindhastigheten, elpriset, livstiden av transformatorn och de valda väderdata. Från känslighetsanalysen så var det möjligt att dra slutsatsen att vindresurser och elpriset är nyckelparametrar för vindkraftsparkens genomförbarhet.
THIBBLIN, CECILIA. "Managing a business change : framework for measuring and controlling businesses." Thesis, KTH, Entreprenörskap och Innovation, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-147787.
Full textDagens föränderliga marknad gör det allt mer viktigt för företag att kunna förändra och anpassa sig till olika marknaders dynamik. Företag som lyckas genomgå en förändring skiljer sig ofta från de som går i konkurs. Nyckeltal är ett verktyg som gör det möjligt för företag att mäta var de står i förhållande till andra företag, men också för att veta vart de vill och vart de är på väg. I och med att förändring är nödvändigt blir det allt vanligare för företag att ta hjälp utifrån av företag som är experter på förändring. Studier visar även på detta, då en trendförskjutning har skett de senaste 15 åren, där företag har blivit mer benägna att ta hjälp av experter gällande förändringsarbete, dels för att minska belastningen på den egna personalen men också för att kunna fokusera på den ordinarie verksamheten. Transformator Design är en av dessa experter och deras önskan om att välja ut "de bästa" nyckeltalen, för förändring, med fokus på kunden, är grunden till detta examensarbete. Fortsättningsvis är målsättningen med studien att bidra med förståelse för hur företag, i allmänhet, bör arbeta med förändringsarbete Studien har, efter granskning av teori och tidigare empiriska studier, utfört intervjuer med de fem företagen SEB, Netsurvey, Telia, Ica och Skandia. Gemensamt för dessa företag är att de alla bedrivit förändringsarbete. Resultatet av teorierna visar på att det inte finns någon generell patentlösning när det kommer till val av nyckeltal, utan att det varierar beroende på vilken typ av verksamhet som ett företag bedriver. Vid val av nyckeltal bör dock samtliga företag, oavsett verksamhet, välja ut sådana som speglar både verksamheten, medarbetarna och kunden. Detta eftersom kunden indirekt påverkas av en nöjd verksamhet med nöjda medarbetare.