Academic literature on the topic 'Validation analytique'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Validation analytique.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Validation analytique"

1

Mannessier, L., F. Roubinet, M. Delamaire, J. Chiaroni, and A. Lejealle. "Validation analytique en immunohématologie érythrocytaire." Transfusion Clinique et Biologique 7 (June 2000): 51s—54s. http://dx.doi.org/10.1016/s1246-7820(00)80017-8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Rabut-Piccione, Elodie, Laëtitia Charbonnier, and Léna Le Flem. "Génotypage RHD fœtal non invasif : validation stabilité pré-analytique > 48 h." Transfusion Clinique et Biologique 26, no. 3 (September 2019): S61. http://dx.doi.org/10.1016/j.tracli.2019.06.093.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Hugny, O., C. Aparicio, K. Lièvre, V. Leduc, and C. Cueille. "Exemple de la validation d’une méthode analytique : dosage de l’allergène majeur Ole e 1." Revue Française d'Allergologie 53, no. 3 (April 2013): 345. http://dx.doi.org/10.1016/j.reval.2013.02.039.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Rivierre, Laurent, Pierre Mignon, and Jean-Luc Campion. "Validation ďun modèle analytique de la pose par poussage des câbles à fibres optiques." Annales Des Télécommunications 56, no. 9-10 (September 2001): 560–68. http://dx.doi.org/10.1007/bf03008833.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Evrard, Marion, Véronique Planas, Sophie Dufay, Nouha Denguir-Rihane, Christelle Pinchon, Jean-Jacques Houri, and Dominique Pradeau. "Validation d’une méthode analytique de dosage du D-mannose par CLHP couplée à un réfractomètre." Le Pharmacien Hospitalier et Clinicien 51, no. 1 (March 2016): 85. http://dx.doi.org/10.1016/j.phclin.2016.01.053.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Allart, E., C. Rogeau, J. Paquereau, F. Beaucamp, W. Daveluy, O. Kozlowski, and M. Rousseaux. "Validation d’une échelle d’évaluation analytique et fonctionnelle de l’équilibre et de la marche chez le patient hémiplégique vasculaire." Annals of Physical and Rehabilitation Medicine 56 (October 2013): e127. http://dx.doi.org/10.1016/j.rehab.2013.07.259.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Chenevier-Gobeaux, C., C. Simonneau, O. G. Ekindjian, B. Weill, and C. Goulvestre. "Dosage automatisé des anticorps anti-peptides cycliques citrullinés (anti-CCP) sur l'analyseur Elecsys®: validation analytique et valeur diagnostique." Annales de biologie clinique 67, no. 4 (July 2009): 405–10. http://dx.doi.org/10.1684/abc.2009.0342.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Bennis, S., F. Berrada, and F. Bernard. "Méthodologie de validation des données hydrométriques en temps réel dans un réseau d'assainissement urbain." Revue des sciences de l'eau 13, no. 4 (April 12, 2005): 483–98. http://dx.doi.org/10.7202/705404ar.

Full text
Abstract:
L'objectif du présent travail est l'élaboration d'une méthodologie de validation des données hydrométriques mesurées dans un réseau d'assainissement. L'information validée est utilisée aussi bien en temps réel, pour optimiser les consignes de gestion, qu'en temps différé, pour poser le véritable diagnostic et évaluer, sur une base quotidienne, l'efficacité des systèmes d'assainissement. Le principe de base de la méthodologie proposée repose sur la redondance analytique de l'information provenant d'une part de la mesure directe du débit sur le terrain et d'autre part du débit simulé à partir des variables météorologiques. On compare ainsi d'une part, l'écart entre la valeur prévue par un modèle autorégressif (AR) et la valeur mesurée et d'autre part, l'écart entre la valeur prévue par ce même modèle AR et la valeur simulée par un modèle hydrologique. Parmi les valeurs, mesurée et simulée, celle qui se rapproche le plus de la valeur prévue est retenue. Afin de considérer des modèles non stationnaires et d'éviter le biais d'estimation des paramètres de régression par la méthode standard des moindres carrés, le filtre de Kalman est utilisé pour identifier les paramètres du modèle AR. La méthodologie proposée a été testée avec succès sur un bassin urbain de la municipalité de Verdun. L'hydrogramme mesuré a été bruité artificiellement à la fois par un bruit blanc et par un certain nombre de perturbations de grandes amplitudes et de différentes formes. Le processus de validation a permis de retrouver pratiquement les mesures initiales, non bruitées. Les critères de performance introduits sont largement concluants.
APA, Harvard, Vancouver, ISO, and other styles
9

Charmelot, R., M. Sonnery Bouillon, F. Khayi, and D. Kryza. "Mise au point et validation d’une méthode analytique par CLHP et CCM du PSMA-I&T radiomarqué au 177-Lutétium." Médecine Nucléaire 45, no. 4 (July 2021): 188. http://dx.doi.org/10.1016/j.mednuc.2021.06.033.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Lajzerowicz, Céline, Yves-Marie Vincent, and Catherine Jung. "La supervision indirecte idéale d’après l’expérience des internes en stage autonome en soins primaires ambulatoires supervisé." Pédagogie Médicale 19, no. 1 (February 2018): 27–35. http://dx.doi.org/10.1051/pmed/2019004.

Full text
Abstract:
Contexte et objectif : Pendant le stage autonome en soins primaires ambulatoires supervisé (SASPAS), l’interne réalise seul les consultations médicales. Son maître de stage lui apporte une rétroaction régulière lors de séances de supervision indirecte (SI). L’objectif de cette étude est d’explorer l’expérience de la SI par les internes en SASPAS, afin de faire émerger les caractéristiques de la séance de supervision idéale de leur point de vue. Méthodes : Une étude qualitative par entretiens individuels semi-dirigés a été réalisée auprès des internes en SASPAS en Aquitaine. Une analyse thématique de contenu a été menée dans une approche analytique inductive. Résultats : Douze entretiens ont été réalisés entre janvier et mars 2017. Les internes ont décrit la séance de SI idéale comme un temps pédagogique centré sur l’interne et sa pratique, dans un climat de bienveillance et d’échange entre « pairs ». Elle se déroule dans un temps et un espace dédié. La rétroaction, guidée par le maître de stage expert, est une dynamique entre validation de l’action et critique sous forme de marge de progression. L’enjeu est le développement de la réflexivité, des compétences et du sentiment d’efficacité personnelle. Conclusion : La séance de SI idéale présente les caractéristiques d’une supervision formative, centrée sur l’interne en formation. La réflexion développée sur cet outil pédagogique peut favoriser son appropriation par le maître de stage et l’interne, et amener à une amélioration des pratiques de supervision.
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Validation analytique"

1

Nguyen, Trong Hoan. "Développement et validation d'une méthode analytique de prévision de l'érosion de cavitation." Grenoble INPG, 1994. http://www.theses.fr/1994INPG0010.

Full text
Abstract:
Le present travail est consacre au developpement et a la validation d'une technique de prevision de l'erosion par cavitation. La premiere etape consiste a caracteriser par une methode semi-empirique l'agressivite hydrodynamique de l'ecoulement cavitant. Celle-ci basee d'une part sur la realisation d'essais de marquage et d'autre part sur la mesure in-situ des surpressions instantanees responsables de l'erosion. Des capteurs de pression ont ete realises specifiquement pour cette application a partir de films piezoelectriques en polyfluorure de vinylidene. Deux methodes d'etalonnage dynamique ont ete mises en uvre et une technique de traitement du signal a ete developpee. La deuxieme etape consiste a analyser la reponse du materiau a cette agressivite en vue d'estimer la perte de masse. Le materiau est ici caracterise par ses proprietes mecaniques classiques et des caracteristiques metallurgiques d'ecrouissage. L'ensemble de la methode est appliquee au cas de l'erosion produit dans une boucle a mercure. Une partie du travail est egalement consacree a l'analyse de l'effet d'un changement d'echelle geometrique sur le phenomene d'erosion par cavitation
APA, Harvard, Vancouver, ISO, and other styles
2

Tachon, Philippe. "Mise au point et validation de méthodes d'analyse pour un automate de laboratoire." Bordeaux 2, 1995. http://www.theses.fr/1995BOR2P024.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Dehee, Axelle. "Charge virale EBV : développement et validation analytique d'une technique d'amplification génique en temps réel." Paris 5, 1998. http://www.theses.fr/1998PA05P049.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Vialaret, Jerome. "Développement et validation de méthodes de protéomique innovantes pour des applications de biochimie clinique." Thesis, Montpellier, 2019. http://www.theses.fr/2019MONTT038.

Full text
Abstract:
Depuis quelques années, la spectrométrie de masse est considérée comme la méthode de référence en chimie analytique. La « protéomique », concept qui a émergé dans les années 2000, consiste en l’identification et/ou la quantification d’un ensemble de peptides et protéines présentes dans un échantillon donné (cellules, tissus, ou des prélèvements biologiques), à un instant donné. Un champ plus spécifique de ce concept, la « protéomique clinique » concerne plus particulièrement l’étude du protéome pour la recherche d’une part, de marqueurs diagnostiques, pronostiques et de suivi thérapeutique des pathologies humaines et, d’autre part, d’acteurs physiopathologiques pouvant servir de cible thérapeutique. Actuellement, la technologie de choix utilisée pour l’analyse des protéines en biochimie clinique est le dosage immuno-enzymatique de type ELISA qui possède des inconvénients majeurs : pas ou peu multiplexable, une grande variabilité, pas de standardisation interne et l’incapacité à distinguer des protéoformes d'une même protéine. La protéomique ciblée de type Liquid Chromatography/Multiple Reaction Monitoring (LC-MRM) permet de surpasser ces inconvénients car elle est multiplexable (>200 protéines/expérimentations), robuste, permet l’utilisation de standard protéique/peptidique interne, et permet de distinguer une grande variété de modifications post traductionnelles.Ce projet de thèse consiste donc à évaluer et valider des techniques de spectrométrie de masse ciblées de type LC-MRM pour la quantification de protéines d’intérêt cliniques. Dans ce cadre, nous allons présenter trois développements de méthode de protéomique clinique : le phénotypage de l’Apolipoprotéine E, facteur de risque de la maladie d’Alzheimer ; la quantification sérique d’un anticorps monoclonal thérapeutique (Bevacizumab) avec immuno-enrichissement ; et la quantification absolue de l’hepcidine dans le cadre des pathologies liées au métabolisme du fer
In recent years, mass spectrometry has been considered in the analytical chemistry field as the reference method. "Proteomics", a concept that emerged in the 2000s, consists in the identification and/or quantification of peptides and proteins in different type of samples (cells, tissues, or biological samples), in various conditions. A more specific field of this concept, the "clinical proteomics" specifically concerns the study of proteome for the research on one hand, diagnostic markers, prognostic and therapeutic follow-up of human pathologies and, on the other hand, of pathophysiological actors that can serve as a therapeutic target.Currently, the technology of choice used for the analysis of proteins in clinical biochemistry is the ELISA (Enzyme-linked immunosorbent assay) which has major drawbacks: not a multiplex analysis, high variability, no standardization, and the inability to distinguish proteoforms of one protein. The targeted proteomics by Liquid Chromatography/Multiple Reaction Monitoring (LC-MRM) allows to surpass these disadvantages because is highly multiplexable (> 200 proteins/analysis), robust, compatible to the use of protein/peptide standards, and is able to distinguish a wide variety of post translational modifications.In this thesis project, evaluation and validation of the targeted mass spectrometry (LC-MRM) will be perform for the quantification of proteins with clinical interest. In this context, we will present three clinical proteomics developments: apolipoprotein E phenotyping, considered as the best risk factor for Alzheimer's disease; Monoclonal therapeutic antibody (Bevacizumab) quantification in patient serum; and absolute quantification of hepcidin-25 in the context of diseases related to iron metabolism
APA, Harvard, Vancouver, ISO, and other styles
5

Tchamitchian, Marc. "Photosynthèse d'une culture de tomates sous serre : mise au point et validation d'un modèle analytique." Toulouse, INPT, 1990. http://www.theses.fr/1990INPT019A.

Full text
Abstract:
Un modele probabiliste d'absorption lumineuse (sinoquet 1989) a ete modifie pour decrire la distribution de surface foliaire par rapport au rayonnement par incident. Cette distribution est utilisee par des fonctions de reponse photosynthetique foliaire, variant avec l'age des feuilles, pour donner une cartographie de l'activite des plantes, ainsi que sa photosynthese totale, calculee par integration des activites foliaires. Le module d'interception lumineuse a ete cale sur une culture de printemps de tomates de serre. Des relations statistiques entre les composantes du rayonnement, direct et diffus, dans la serre et a l'exterieur, ont ete etablies pour permettre les simulations. Sur cette meme culture, la photosynthese de plantes entieres a ete mesuree pour valider le modele de photosynthese. Mesures et simulations de la photosynthese totale sont en bon accord. La routine d'interception lumineuse et la cartographie de l'activite photosynthetique necessitent cependant une validation plus detaillee. La souplesse de ce modele permet de simuler les differents modes de conduites (densites, arrangements des rangs) existants sous serre
APA, Harvard, Vancouver, ISO, and other styles
6

Alberti, Christophe. "Validation de données et redondance analytique : application à une usine de traitement des eaux usées." Corte, 2002. http://www.theses.fr/2002CORT3065.

Full text
Abstract:
Lors de la conduite des processus industriels, une des préocupations majeures des opérateurs concerne la fiabilité des informations fournies par l'instrumentation. La seul connaissance des mesures effectuées s'avère insuffisante pour donner une image complète et réaliste de l'état du système. En complément de cette volonté de s'assurer une image réaliste de l'état du procédé, les automaticiens se sont depuis longtemps penché sur le problème de la détection d'une anomalie dans le fonctionnement du processus. Une méthode de diagnostic d'un procédé doit se donner les moyens de réaliser au moins une des fonctions suivantes : détecter une défaillance, localiser cette défaillance, estimer le biais induit par la défaillance sur le comportement du procédé. Dans cette thèse, nous nous intéresserons plus particulièrement à l'étude du degré de redondance des systèmes et de la fiabilité qui en découle. De nombreux travaux relatifs à l'étude des systèmes linéaires et multilinéaires ont été menés. Nous en citerons plusieurs, qui traitent aussi bien de l'observabilité que de l'estimation d'état. Ces travaux concernent des réseaux du type transport de matière, et les contraintes qui y sont rattachées sont du type bilan-matière. Nous allons dans un premier temps présenter le cadre de l'étude et rappeler les principes existant en terme de surveillance des procédés. Dans le chapitre II, nous allons développer les notions de degré de redondance des variables et présenter une méthodologie afin de le déterminer pour les systèmes linéaires et bilinéaires. Nous proposons également le calcul de la fiabilité d'une instrumentation donnée. Le chapitre III présente la technique d'estimation d'état et d'étude du degré de redondance appliquées à un procédé de traitement des eaux usées de Bastia. Dans cette partie, on se propose également de modéliser par un modèle ARMA saisonnier le débit entrant dans la station afin de prédire en cas de défaillance du capteur associé.
APA, Harvard, Vancouver, ISO, and other styles
7

JONVEL, PATRICK. "Objectif : validation; implications reglementaires et pratiques pour les laboratoires de chimie analytique de l'industrie pharmaceutique." Université Louis Pasteur (Strasbourg) (1971-2008), 1992. http://www.theses.fr/1992STR15061.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Amagbégnon, Apollinaire-Roland. "Approches analytique et numérique des modes acoustiques en canal rectangulaire avec un obstacle sphérique : validation expérimentale." Poitiers, 1996. http://www.theses.fr/1996POIT2349.

Full text
Abstract:
Nous presentons dans cette these un principe de decomposition des modes propres dans les conduits rectangulaires a l'aide de la sonde intensimetrique tridirectionnelle spherique. La premiere etape du travail consiste en l'evaluation de la diffraction engendree par la sonde et au calcul de la pression acoustique pour chaque mode individuel par une formulation analytique. Une approche numerique fondee sur la methode des elements finis a ete envisagee pour le meme probleme et a aboutit a des resultats parfaitement en accord avec la theorie surtout pour la frequence. Enfin, des experiences menees sur deux canaux de dimensions differentes ont permis de valider les deux theories. Ce travail a aussi fait la preuve que la sonde pouvait etre un bon outil de mesure dans les conduits si ces derniers ont des dimensions suffisamment importantes afin que les autres types de perturbation en l'occurrence celle de la dissipation par viscosite ne predominent sur les effets de la diffraction
APA, Harvard, Vancouver, ISO, and other styles
9

Ghouali, Mohamed Amine. "NNouvel outil-d'aide à la conception de formes optimales : analyse de sensibilité analytique locale : principes, validation et applications." Cachan, Ecole normale supérieure, 1997. http://www.theses.fr/1997DENS0018.

Full text
Abstract:
Cette thèse fait l'objet du développement d'un outil d'aide a la conception de forme optimale. Il s'agit de la méthode d'analyse de sensibilité analytique locale. Celle-ci consiste à évaluer la sensibilité (dérivée partielle) d'un champ (déplacements, contraintes,. . . ) solution d'un problème aux limites elliptique. Cette sensibilité sera ensuite utilisée pour le calcul du gradient du critère d'optimisation. L'approche analytique de la méthodologie a été d'abord précisée en confrontant celle-ci a une méthode (analytique) d'analyse de sensibilité globale, dans le cas des problèmes de Dirichlet, de Neumann et mixte. Elle a été ensuite confirmée sur un certain nombre d'applications (mécaniques) simples disposant de solutions analytiques. La mise en œuvre numérique de ces dernières applications par la méthode des éléments finis et/ou la méthode des éléments de frontière a été réalisée avec beaucoup de succès. Ce travail se distingue aussi par une étude orientée vers deux applications, a caractère plus général, et dont l'intérêt industriel est considérable. La première application vise l'optimisation du comportement homogénéise des structures composites a renforts unidirectionnels. Pour ce faire, un couplage de l'outil propose a la technique d'homogénéisation a été réalisé en écrivant l'analyse de sensibilité locale des problèmes cellulaires associes au composite. Sa mise en œuvre numérique (lansdru, logiciel d'analyse de sensibilité locale des composites a renforts unidirectionnels implante dans la bibliothèque éléments finis modulef) a conduit a des résultats d'optimisation très intéressants. La seconde application rentre dans le cadre de l'optimisation des gammes de forgeage. En effet, l'analyse de sensibilité locale du problème de forgeage évolutif et fortement non linéaire (comportement viscoplastique, frottement non linéaire, contact bilatéral, contact unilatéral,. . . Etc. ) a été proposée. Les résultats numériques de sensibilité obtenus par lasl, logiciel d'analyse de sensibilité locale implante dans forge2, sont très satisfaisants.
APA, Harvard, Vancouver, ISO, and other styles
10

Amara, Salah. "Elaboration et validation d'un modèle de transferts thermiques instationnaires gaz-paroi dans la chambre de combustion d'un moteur." Ecully, Ecole centrale de Lyon, 1994. http://bibli.ec-lyon.fr/exl-doc/TH_T1547_samara.pdf.

Full text
Abstract:
Les variations rapides de pression et de température influent considérablement sur les échanges thermiques instantanés entre le gaz et les parois de la chambre de combustion. Une étude expérimentale de la densité surfacique du flux de chaleur échangé en deux points de la paroi de la culasse a permis en effet de mettre en évidence l'accumulation d'énergie dans la couche limite thermique qui se manifeste par un déphasage temporel entre le flux et l'écart de température global gaz-paroi. En régime laminaire instationnaire, une simulation de ces échanges fait bien apparaître des extrema locaux de température dans la couche limite thermique. Une interprétation du mécanisme de formation et de déplacement de ces extrema est donnée. Les échanges thermiques en régime turbulent sont décrits à l'aide du modèle monodimensionnel de yang et martin ou l'effet de la turbulence est pris en compte par le biais de la conductivité thermique turbulente. Ce modèle a été modifie pour limiter l'augmentation de la conductivité thermique turbulente avec la distance à la paroi. Le paramètre de limitation est lié à la valeur locale de la viscosité turbulente. Le modèle ainsi obtenu permet une meilleure détermination de l'épaisseur de la couche limite thermique et s'adapte de lui-même à toute situation intermédiaire entre le régime laminaire et les régimes fortement turbulents, la densité du flux de chaleur étant modulée en conséquence. L'implantation de ce modèle dans le code de simulation kiva2 a montré que la prise en compte des instationnarités de température et de pression constitue une amélioration par rapport aux lois de paroi logarithmiques mais se révèle insuffisante. Une superposition du modèle monodimensionnel et d'une loi de paroi logarithmique rendant compte de l'effet de la vitesse tangentielle donne des résultats se rapprochant au mieux des évolutions expérimentales et ceci pour différentes vitesses de rotation. Une étude paramétrique comparative est ensuite réalisée pour montrer l'impact du choix d'un modèle de calcul du flux de chaleur pariétal sur la détermination des champs de vitesse, de température, d'énergie cinétique turbulente et de son taux de dissipation à la fin de la course de compression.
APA, Harvard, Vancouver, ISO, and other styles
More sources
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography