To see the other types of publications on this topic, follow the link: Värmeåtervinning.

Dissertations / Theses on the topic 'Värmeåtervinning'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Värmeåtervinning.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

Ahlqvist, Björn. "Värmeåtervinning från kylsystem : Uddeholm AB." Thesis, Innovations- och designingenjörsprogrammet, 2011. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-8171.

Full text
Abstract:
Sammanfattning Uddeholm AB är en världsledande leverantör och tillverkare av verktygsstål med ca 3 500 anställda världen över. Under de närmaste åren planeras ökad produktion och miljökrav blir allt hårdare. För att klara detta utförs en rad viktiga investeringar. En av dem är att minska utsläppet av kylvatten och ta tillvara på spillvärme från produktionen. Projektet har utförts på Granmelt som är en avdelning under stålverket. Här omvandlas stålskrot till kulor, även kallat granulat. Första steget i processen är att smälta stålskrot. Detta sker i högfrekventa induktionsugnar. Induktionsspolen i ugnarna måste kylas för att undvika överhettning. Kyleffekten erhålls genom att låta vatten transportera värmeenergi från ugnskomponenterna till en värmeväxlare. Syftet med projektet är att förbättra kylsystemet, ta tillvara på spillvärmen och på det viset minska miljöpåverkan samt spara energi.    En viktig del i projektet har varit insamling av data från befintligt system. Intervjuer och litteraturstudier har också genomförts. Informationen har legat till grund för olika förslag på hur systemet skall konstrueras och spillvärmen användas. Genom beräkningar redogörs hur mycket tillgänglig värmeenergi det går att utvinna, vilka värmekällor som kan ersättas och hur mycket pengar företaget sparar. Konstruktionen är visualiserad med schematiska ritningar som beskriver flödet genom systemet och dess komponenter. Rapporten innehåller också skisser och ritningar för att förbättra layouten med tanke på underhållsarbete. Resultatet av projektet är att det nya systemet ersätter en stor del av befintliga värmekällor för uppvärmning av lokaler. Vattenkonsumtionen minskar kraftigt genom att två slutna slingor används. Återbetalningstiden för nyinstallationen är mindre än två år. Efter tio år har företaget sparat över tre miljoner kronor i uppvärmningskostnader genom att använda spillvärmen.<br>AbstractUddeholm AB is a leading global supplier and manufacturer of tool steel with about 3500 employees worldwide. Over the next few years production will increase and environmental requirements are becoming tougher. To manage this series of important investments are implemented. One of them is to reduce the consumption of cooling water and make use of residual heat generated by the production. The project has been performed at Granmelt which is a sub section to the steel mill. At this section scrap metal is melted and granulated for production of refined steel. The first step in the process is melting in high frequency induction furnaces. Some components in the furnace must be cooled to avoid overheating. The cooling effect is obtained by water transferring heat energy from the furnace components to a heat exchanger.  The project aims to improve the cooling system, take advantage of waste heat, thereby reducing environmental impact and save energy. An important part of the project has been collecting data from existing systems. The information has been the basis of various proposals on how the system should be designed and how the waste heat should be used. The design is visualized by schematic drawings that describe the flow through the system and its components. The report also contains sketches and drawings to improve the layout in view of maintenance work. Calculations explain how much available heat energy can be extracted, which heat sources that can be replaced and how much money it will save.The result of this project is that the new system has a payback period under two years, after ten years the company has saved over three million SKR by warming the buildings with the residual heat.
APA, Harvard, Vancouver, ISO, and other styles
2

Hurlov, Almedina. "Värmeåtervinning med spillvatten i flerbostadshus." Thesis, Högskolan i Gävle, Avdelningen för byggnadsteknik, energisystem och miljövetenskap, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-30104.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Öhman, Christian, and Robert Richnau. "Värmeåtervinning från spillvatten i flerbostadshus." Thesis, KTH, Byggteknik och design, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-191252.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Eliasson, Marcus. "Värmeåtervinning från nedlagda vattenfyllda gruvor." Thesis, Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-69796.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Nykvist, Anders. "Värmeåtervinning ur spillvatten i befintliga flerbostadshus." Thesis, KTH, Byggvetenskap, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-91388.

Full text
Abstract:
Drain water heat recovery is an uncommon measure in multi-unit residential buildings. There is technology available for the purpose but the knowing and experience of the heat recovery systems is little. The purpose of this thesis is to evaluate the future potential of drain water heat recovery in multi-unit residential buildings. A major part of the multi-unit residential buildings in Sweden were built during modernismen and rekordåren (1940 – 1975). Many of the buildings have worn out drain and water supply systems and many are in need of a general refurbishment. If drain water heat recovery is considered for a building it is suitable to install the recovery system at the same time as the refurbishment to minimize the installation cost. Existing heat recovery systems consist of heat exchangers, heat pumps or a combination of both. There are passive heat exchangers that are placed close to the shower, on the vertical drain pipe and on the horizontal drain pipe. Recovery systems comprising heat pumps are more complicated and space demanding. They are rarely suited for multi-unit residential buildings but have the potential of recovering more heat from the drain water. In some buildings, where heat recovery systems have been installed, the performance of the systems has been measured. The measurements show that passive heat exchangers can recover about 10 – 15 % of the hot water energy consumption, not including standstill losses and hot water circulation. Calculations indicate that the energy savings for passive heat exchangers could be 20-25 %. If several kinds of heat exchangers are combined the energy savings could be almost 40 %. Recovery systems with heat pumps could generate even larger energy savings, between 50 – 70 %. However, with heat pumps the electricity consumption increases and that has to be considered in profitability calculations. When developing new heat recovery systems the emphasis should be on energy storage and reactivity since most taps are short and unpredictable. In a technology procurement there should be demands on energy effectiveness. Based on experience from installed heat recovery systems and calculations the following is suggested:  The buildings heating and hot water energy consumption must decrease with at least 15 % of the current hot water energy consumption.  The buildings heating and hot water energy consumption should decrease with at least 20 % of the current hot water energy consumption. Furthermore there should be demands on profitability. The present value of future energy savings ought to exceed the investment cost and the present value of future costs of the system within a period of time. The following is suggested:  The condition must be fulfilled within 20 years  The condition should be fulfilled within 15 years iii
APA, Harvard, Vancouver, ISO, and other styles
6

Linder, Kristofer. "Värmeåtervinning av gruvventilationsluft - LKAB i Kiruna." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2011. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-58990.

Full text
Abstract:
For att brytning under jord ska vara mojlig maste stora mangder frisk luft pressas ned till brytningsnivan, vilket gors fran olika gruvventilationsstationer. For att undvika nedisning i schakten varms tilluften upp till 1 . innan luften transporteras ned i berget. Idag sker denna uppvarmning av varmebatterier som nyttjar spillvarme fran kulsinterverken. Finns ett extra varmebehov spetseldas det med olja. Franluften ar fuktig och varm. Det ar darfor intressant att undersoka om det skulle kunna vara mojligt att installera varmevaxling pa gruvventilationsstationerna och nyttja varmen i franluften fran gruvan till att varma tilluften. Varmevaxlarsystem som undersokningen grundar sig pa ar av typen batterivarmevaxlare. Batteritillverkaren skickade ett forslag pa batterityp som skulle klara de krav som stallts och en oert for detta system. Det system som valdes hade 4 tilluftsbatterier av storleken 4500x2000 mm och 3 franluftsbatterier av storleken 8000x2200 mm. Varje tilluftsbatteri hade en dimensionerad eekt av 661 kW och varje franluftsbatteri var dimensionerat till 882 kW. Berakningar pa energibesparingen i olja som varmevaxlingen kunde medfora gjordes. Dessutom raknades det ocksa pa hur mycket spillvarmesenergi som kunde sparas genom att installera varmevaxling. Berakningarna genomfordes pa sammanlagt 9 gruvventilationsstationer, dels varje station for sig, dels om era stationer installerades. Den energi som station 1arligen kunde bespara i olja var ungefar 4,7 GWh per ar. Skulle varmevaxling installeras pa 9 stationer skulle energimangden insparad olja bli ungefar 29 GWh per ar. Den energi som kunde sparas in i station 1 i form av spillvarme var 0,6 GWh per ar. Skulle varmevaxling installeras pa 9 stationer skulle den ersattningsbara spillvarmen vara ungefar 18 GWh per ar. De ekonomiska berakningarna gjordes i tva fall. Ett da berakningarna endast byggde pa fortjansten av insparad olja och ett fall da det aven beraknades att den insparade spillvarmen kunde saljas till TVAB. Den totala installationskostnaden per station beraknades till cirka 4,3 miljoner kr och vid berakning pa bara fortjanst av olja skulleaterbetalningstiden for 1 station bli ungefar 1,4 ar. Med 9 stationer skulle aterbetalningstiden bli 3,6 ar. Tas forsaljning av spillvarme med i beaktning och adderas till fortjansten av olja sa blir aterbetalningstiden for 1 station anda 1,4 ar, men for installation pa 9 stationer blir aterbetalningstiden 2,4 ar. De problem som skulle kunna uppsta ar problem med nedsmutsning, nagot som skulle kunna forebyggas genom storre lamelldelning i batterivarmevaxlarna samt skyddsmalning med Heresite pa franluftsbatterierna. Utbyggnad av franluftskanalen maste ocksa goras da franluftsbatterierna ar for stora for att fa plats i den kanal som nns idag. Berakningarna bygger i alla stationer pa en franluftstemperarur pa 8 . och en relativ fuktighet pa 100 procent. Samma sorts batterivarmevaxlare har alltsa anvants i berakning av de olika stationerna. Vid en ytterligare projektering foreslas att exakta varden for varje station skickas in till batteritillverkaren sa att stationsprecisa batteriprestandakurvor kan beraknas fram. Rekommendation ar att en forsta installation av varmevaxlarsystem genomf ors pa KV10 da dar nns gott om plats nns for installation av tilluftsbatterier samtidigt som den har nast hogst franluftstemperatur.<br>In order to make underground mining production, large amounts of outdoor air must be pushed down to the mining level. At the LKAB facility in Kiruna this is done by a number of mining ventilations stations. The air has to be heated before it is transported down to the mining levels. This is done in order to prevent icing in the shaft. Today, the heating of the air is done by using waste heat from the pellet mills and if extra heating is needed, due to lower outdoor air temperatures, oil is used. The exhaust air from the underground is moist and warm. It is therefore interesting to investigate if it is possible to install a heat exchanger in the mine ventilation stations and use the heat in the exhaust air to heat the supply air. The heat recovery system which has been investigated in this study is a type of coil heat exchanger. Heat exchanger manufacturer has submitted a proposal on the type of coil heat exchanger that could withstand the specic demands and oer a price for the system. The chosen heat recovery system has four supply exchangers with the size 4500x2000 mm and 3 exhaust exchangers with size 8000x2200 mm. Each Supply air coil had a power of 661 kW and each exhaust exchanger was sized at 882 kW. Analyses were made to estimate reductions in the use of oil by implementing the heat recovery system. In addition, also the amount of waste heat energy that could be saved by installing the heat exchangers was calculated. The calculations were carried out on a total of 9 mining ventilation stations. The energy that the rst installed station could save in form of oil during a year has been estimated to 4,7 GWh. If heat exchangers were installed in all the 9 stations the energy reduction would be approximately 29 GWh per year. The energy that could be saved at station 1 in the form of waste heat was 0.6 GWh per year. If heat exchangers were installed at all the 9 stations, the recoverable waste heat was calculated to be approximately 18 GWh per year. The nancial analyses were made for two cases. One that was based only on prots from the saved oil and, the other also by selling of the saved waste heat to TVAB. The total installation cost per station was estimated at to around 4.3 million skr. Considering the saved amount of oil the payback time for a single station was found to be approximately 1.4 years. For all the 9 stations the payback time was estimated to be 3.6 years. If sale of waste heat is included and added to the analysis, the payback time for a single ventilation station is 1,4 years and for an installation in all the stations the payback time is 2,4 years. The problems that could arise are due to contamination, which could be prevented by greater spacing of the battery heat exchangers and protective coating with Heresite. Expansion of the exhaust duct must also be made when the exhaust air coils are too big to t in the available channel . The calculations are based on the assumptions that the temperature of the exhaust air is 8 . and the relative humidity is 100 % in all stations. The same kind of coil heat exchanger has therefore been used in the calculation of the dierent stations. In the next design step it is proposed that more accurate values for each station are provided to the heat exchanger manufacturer to improve design performance of the recovery system. A futher recommendation is that the rst installation of the heat exchange system should be implemented in ventilation station KV10 where there is plenty of space available for a heat exchanger system, and KV10 also has the second highest exhaust air temperature.
APA, Harvard, Vancouver, ISO, and other styles
7

Björklund, Erik, and Linus Hansson. "VÄRMEÅTERVINNING I ALBANO : Energieffektivisering i studentbostäder." Thesis, KTH, Industriell ekologi, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-139087.

Full text
Abstract:
Rapporten beskriver undersökningen av två värmeåtervinningsmetoder, frånluftsvärmepump och frånlufts/tilluftsvärmeväxlingssystem (FTX-system), för en av Svenska Bostäders byggnader i det kommande byggprojektet i Albano. Syftet var att göra detta utifrån hållbarhetsaspekterna energieffektivitet, klimatpåverkan i form av växthusgasutsläpp samt driftskostnader för inköpt energi. Uppbyggnad av en värmeflödesmodell, baserad på en av byggnaderna i området, samt energiberäkningar för respektive uppvärmningssystem, visade att det relativt nollalternativ gick att spara 55 % av uppvärmningsbehovet om frånluftsvärmepumpen väljs och 45 % om FTX-systemet väljs. Totalt sett tyder resultaten på att frånluftsvärmepumpsystemet utgör ett något mer fördelaktigt alternativ, men om den studerade byggnadens totala klimatskalsprestanda kan uppnå mycket låga värmegenomgångstal utgör FTX-alternativet det bättre alternativet.<br>The report describes the investigation of two heat recovery methods, an exhaust air heat pump and an exhaust/supply air heat exchange system (FTX), for use in Svenska Bostäder’s buildings in the upcoming construction project in Albano. The aim was to do this based on the sustainability aspects of energy efficiency, environmental impact in terms of greenhouse gas emissions and operating costs for purchased energy. The construction of a heat flow model, based on one of the buildings in the area, as well as energy calculations for each heating system, showed that 55% of the heating requirement could be saved with the exhaust air heat pump option, while 45% if the FTX system was selected. Overall, the results suggest that the exhaust air heat pump system is a slightly more favorable option, but if the studied building’s total envelope can achieve a very low heat transfer coefficient, the FTX option is superior.
APA, Harvard, Vancouver, ISO, and other styles
8

Johansson, Robert. "Utvärdering värmeåtervinning av spillvärme : Fallstudie Gävleborg." Thesis, Högskolan i Gävle, Avdelningen för bygg- energi- och miljöteknik, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-17273.

Full text
Abstract:
Jordens klimat är idag tunga frågor, det handlar om allt från polarisen som smälter på grund av den stigande temperaturen till sinande oljeresurser i världen. Arbetets mål är att minska energianvändningen, uppskatta vad ett sådant system skulle kosta och vad blir miljövinsten? Med hjälp av en energikartläggning identifieras energiflödena samt ett koncept tas fram för värmeåtervinning med värmeåtervinningsbatteri och värmepump. En kostnadsbedömning och resultatkalkyl görs med konceptet som grund. Resultatet blir ett system som kostar runt 5,3mnkr med en payoff-tid på ca 4 år. Arbetet minskar \(CO_2\)-utsläppen med ca 747ton vilket motsvarar 738 resor med flyg från Stockholm till New York tur och retur.<br>Today's climate change is a big issue, it covers everything from the polar ice melting due to rising temperatures to dwindling oil resources in the world. This paper aims to reduce the energy use, estimate what such a system would cost and what will be the environmental benefit? With the help of an energy audit identifies energy flows as well as a heat scource and a heat sink. A concept was made with the run-around for a heat pump and heat exchanger. A cost assessment and profit and loss statement is done with the concept as a basis. The result is a system that cost around 5.3 million with a payoff period of about 4 years. Work decreases \(CO_2 \) emissions by about 747ton which is equivalent to 738 Flight from Stockholm to New York and back.
APA, Harvard, Vancouver, ISO, and other styles
9

Ali, Rony. "Värmeåtervinning - styrning för frånluftsvärmepump i flerbostadshus." Thesis, Högskolan i Gävle, Avdelningen för elektroteknik, matematik och naturvetenskap, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-30041.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Halvarsson, Niklas, and Sayf Alwali. "Förutsättningar för värmeåtervinning hos Magnihill AB." Thesis, Linnéuniversitetet, Sjöfartshögskolan (SJÖ), 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-55376.

Full text
Abstract:
Magnihill AB har en ambition att ingenting skall gå till spillo, och har begärt att deras mest energikrävande processer skall undersökas, detta för att minska den mängd värmeenergi som används. Magnihill har processer som kräver stora mängder av ånga för att fungera, men även olika källor av överskottsvärme som inte tidigare setts över, som till exempel avgaserna från ångpannan. Fokus lades ned på Magnihills största spillvärme källor, med dessa lösningsförslag, kan Magnihill bli en grönare och mer konkurrenskraftigt företag.
APA, Harvard, Vancouver, ISO, and other styles
11

Nordbåge, Peter, and Anton Engwall. "Energianvändning för driftsatta ventilationsaggregat med värmeåtervinning." Thesis, KTH, Byggteknik och design, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-230887.

Full text
Abstract:
I dagens samhälle ligger stort fokus på energianvändningen för bostäder och kommersiella fastigheter. Energianvändningen beskriver inte bara en byggnads energibehov, utan också miljö- och ekonomiska aspekter. Flerbostadshus är en del av Sveriges bostad- och servicesektor, som utgör 40 % av Sveriges totala energianvändning (Henning, 2017). Ventilationssystem i flerbostadshus utgör således en betydande del av fastighetens energianvändning och måste därför ständigt effektiviseras för att tjäna ett hållbart samhälle. I nuläget är den verkliga energianvändningen för ett flertal av JM:s driftsatta FTX-aggregat (till- och frånluftssystem med värmeåtervinning) okänd. Detta på grund av att tillgängliga energiberäkningar och deklarationer redovisar byggnadens totala energianvändning uppdelat i fyra huvudkategorier; uppvärmning, komfortkyla, tappvatten och byggnadens fastighetsenergi. Energianvändningen för ventilationssystemet framgår inte specifikt från dessa beräkningar, utan delas in i kategorierna uppvärmning och byggnadens fastighetsenergi. Rapporten undersöker, under perioden mars – juni 2018, energianvändningen för totalt elva stycken FTX-aggregat i två av JM:s projekt i Stockholm, Kista Torn och Nya Kvarnen 2. Undersökningens syfte är att försöka beräkna den verkliga energianvändningen för dessa FTX-aggregat. Energiberäkningar har genomförts med värden hämtade från egna samt tidigare utförda mätningar, som jämförts med projekterade värden. Resultatet indikerar att den genomsnittliga energianvändningen för FTX-aggregaten i Kista Torn är ca 120 000 kWh/år. Den större delen av energianvändningen går åt till att värma tilluften. Undersökningen visar på att den genomsnittliga temperaturverkningsgraden är ca 7 % lägre än den projekterade verkningsgraden. De beräkningar som genomförts visar även att uppvärmningskostnaden har ökat med ca 150 000 kr/år, i jämförelse med de projekterade värdena. Det beror till stor del på den minskade temperaturverkningsgraden, men också på grund av förändrade luftflöden i aggregaten. Undersökningen i Nya Kvarnen 2 har inte kunnat göras lika omfattande. Beräkningarna som genomförts här tyder på att energianvändningen uppgår till ca 61 000 kWh/år och aggregat. Tillförlitligheten av beräkningarna störs dock av att inga egna mätningar kunde utföras, att dokumentationen var bristfällig, samt att övervakningssystemet SCADA redovisade orimliga värden. Slutsatsen för rapporten indikerar att den verkliga energianvändningen för FTX-aggregaten generellt är högre än vad som tidigare projekterats. Energianvändningen varierar markant beroende på luftflöden och temperaturverkningsgrad. Störst påverkan på energianvändningen har dock temperaturverkningsgraden. Det visade sig att temperaturverkningsgraden vara svår att bestämma, då många felkällor och faktorer påverkar framtagningen, samt att resultatet varierar beroende på vald mätmetod. För bättre kontroll på energianvändning rekommenderas fler och mer kontinuerligt genomförda mätningar. Alternativt skulle övervakningsprogrammet SCADA kunna användas i större utsträckning för beräkning av energianvändning, förutsatt att precisionen och placering av temperaturgivare förbättras.<br>In today's society the energy use within residential and commercial real estate is of great importance. Energy use does not only describe a building's energy needs, but also its environmental and economic aspects. Apartment buildings are a part the Swedish residential and service sector, which constitutes 40 % of Sweden's total energy use (Henning, 2017). The ventilation system in apartment buildings makes up a significant part of the property's energy use, it must therefore continuously be improved to work towards a more sustainable society. The actual energy use for several of JM's powered air assemblies is unknown today. Energy calculations and declarations show that the building's total energy use is divided into four main categories; heating, comfort cooling, tap water and property energy. The energy use of the ventilation system is not made apparent in these aforementioned calculations since it is distrubuted into two of the main categories, heating and property energy. The report examines the energy use for a total of eleven air assemblies within two of JM's projects in Stockholm, Kista Torn and Nya Kvarnen 2. The purpose of the study is to find the actual energy use of these air assemblies. Energy calculations will be carried out using values ​​taken from our own and previously performed measurements, which will be compared to expected projected data. The result indicate that the average energy use of the air assemblies in Kista Tower is approximately 120 000 kWh/year. The majority of the energy use goes to heating the supply air. The study shows that the average heat recovery efficiency is circa 7 % lower than the projected efficiency. The calculations show that the cost of heating has increased by approximately 150 000 SEK/year compared to projected data. This is largely due to the reduced heat recovery efficiency but partly due to changes in the airflow within the air assemblies. The study made in Nya Kvarnen 2 was not as extensive, although calculations of energy use have been carried out. These calculations show an energy use of approximately 61 000 kWh/year for each separate air assembly. The reliability of these numbers is considered low because no control measurements could be made. The documentation was inadequate along with the monitoring system, SCADA, which reported unrealistic values. The conclusion of the report shows that the actual energy use of the air assemblies is in general higher than expected. The energy use varies depending on the airflow and heat recovery efficiency, however the greatest impact comes from the heat recovery efficiency in the air assemblies. Heat recovery efficiency was proven difficult to determine because of the multiple sources and factors affecting the measurement. This made the results fluctuate greatly depending on the method chosen of calculating the heat recovery efficiency. To oversee the actual energy use in these air assemblies, more frequent measurements are recommended. Alternatively, the SCADA monitoring program could be used to calculate the energy use, but to do so the accuracy and placement of temperature sensors needs to be improved.
APA, Harvard, Vancouver, ISO, and other styles
12

Abdi, Faisa, and Muse Farah. "Energieffektivisering av Limatvätten AB : Värmeåtervinning från manglar." Thesis, Högskolan Dalarna, Energiteknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:du-28697.

Full text
Abstract:
Energieffektivisering är intressant för alla industrier, eftersom det handlar om minskning av både energianvändning och kostnad. Syftet med detta examensarbete är att analysera potentiell energiåtervinning av spillvärme från en mangel vid Limatvätten AB. Limatvätten AB är en stor och modern tvätterianläggning. Limatvätten tvättar åt främst hotell- och restaurangkunder. Limatvätten AB har egna textilier som hyrs ut till hotell, konferenser m.m. Största kunderna finns i Sälenfjällen och Siljansregionen. Då inga processdata fanns tillgängliga för detta arbete krävdes mätningar för att få basinformationen. Utifrån mätningar beräknas mängden av energi som kan återvinnas. Systemförslag för värmeåtervinning ges även i rapporten. Aquavent är en värmeväxlare som använder ventilationsvärme från manglar. Vattnet som värms upp i aquavent leds in i tvättrören, vilket leder till minskning av ångförbrukning i tvättprocesser. Temperaturförändring är beroende av värmeväxlarens verkningsgrad, ju högre temperaturförändring det är desto mer mängd av energiåtervinning fås. Efter identifiering av problemet kartlades tidsplan, lämpliga instrument samt intressanta parametrar. Fukthalten, temperaturen och dynamiska trycket har mätts. Formlerna som beskrivs i teoriavsnittet har använts till de flesta beräkningarna med hjälp av Excel. Av resultatet framkommer att maximala energibesparingen blir 184 MWh/år om all överskottsvärme från manglarna återanvänds. Utifrån resultatet blir den totala besparingspotentialen på 57 000 SEK/år. Ytterligare kompletterande mätningar och analyser behövs för att få tillräckligt bra beslutsunderlag. Men detta arbete tyder på att ytterligare analys är intressant. Resultaten visar det att finns potential att använda överskottsvärme från Limatvättens manglar. Förutom besparingen av energin så minskas också klimatpåverkan eftersom överskottsenergin återanvänds igen som annars skulle försvinna ut i atmosfären. Om två av manglarna kopplas med ett värmeåtervinningssystem, resulterar det en dubblering på besparingspotentialen. För att få ett mera noggrant resultat kunde man logga en längre tid för mätningarna för att se förändring kring de mätande storheterna t.ex. genom att installera mätare som loggar till en dag eller till med en vecka. Övervakning och tolererande givare behövs dock.<br>Energy efficiency is in the interest of all industries, as it involves the reduction of both energy and cost. The purpose of this project for a bachelor’s degree is to analyse potential energy recovery of waste heat from an ironer. The work was carried out at Limatvätten AB, which is a large and modern laundry facility. Limatvätten AB is a textile service company that has been in existence for 50 years. The Lima laundry’s main customers are from the hotel and restaurant business. Limatvätten AB has its own textiles that are rented to hotels, conferences, etc. The largest customers are in Sälenfjällen and in the Siljan region. The work is done by identifying moisture, temperature and dynamic pressure in an ironer Based on measurements, the amount of energy that can be recycled is calculated. Heat recovery system proposals are also given in the report. Aquavent is a heat exchanger that uses ventilation heat from the ironers. The water that is heated in the aquavent is led into the washing pipes, which leads to the reduction of steam consumption in washing processes. Temperature change depends on the heat exchanger's efficiency, the higher the temperature change, the more amount of energy recovery is obtained. After identification of the problem, a timetable was mapped, and appropriate instruments and interesting parameters were chosen. The moisture content, temperature and dynamic pressure have been measured. The equations described in the theory section are used for most of the calculations with the help of Excel. According to the result, the energy saving will be 184 MWh/year if all excess heat from a mangle is reused. Based on the result, the total savings potential is SEK 57 000 /year. According to the results, it is shown that there is the potential to use excess heat from the Lima wash ironers. In addition to the saving of energy, climate impact is also reduced, as the excess energy is again reused which would otherwise disappear into the atmosphere. If two of the ironers are coupled with a heat recovery system, it results in a doubling on the savings potential.
APA, Harvard, Vancouver, ISO, and other styles
13

Cedergren, Jessica. "Värmeåtervinning från smidesprocess : Värme från smidesprocess blir varmvatten." Thesis, Mälardalen University, School of Sustainable Development of Society and Technology, 2008. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-670.

Full text
Abstract:
<p>Sammandrag</p><p>Detta examensarbete utförs i samarbete med företaget Componenta Wirsbo AB. Componenta smider detaljer till den tunga fordonsindustrin. Företaget använder sig av sänksmide där materialet formas genom slag från två rörliga verktyg. Smitt material har mycket goda hållfasthets egenskaper samt en mycket homogen struktur.</p><p>Företaget har som miljömål att minska sin uppvärmningsenergi med 5 %. Componenta arbetar även med ett Leanprojekt som ska leda till en mer kontinuerlig produktion. Det föreslagna värmeåtervinningssystemet kommer även att avsevärt korta avkylningstiden för detaljerna och på så sätt bidra till en mer störningsfri produktion. Detta projekt går ut på att dimensionera en anläggning för värmeåtervinning av kylvattnet från de färdigsmidda detaljerna. Det uppvärmda vattnet kan sedan användas till att värma tappvarmvatten och lokaluppvärmning. För dimensionering av anläggningen genomfördes praktiska test. I dessa test nedsänktes korgar med de smidda detaljerna i vatten och temperaturändringen på detaljerna och vattnet uppmättes. Resultatet av testerna visade att det går att utvinna ca 65 kWh energi ur varje korg med detaljer. Med värmeåtervinning av detaljerna från den mekaniska pressen kan i stort sett endast företagets varmvattenbehov täckas. Om hela produktionen värmeåtervinns kan utöver tappvarmvattenbehovet, ca 50 % av lokaluppvärmningsbehovet tillgodoses. De praktiska testerna visade att korgarna behöver ca 4 - 6 minuter i vattenbadet för att uppnå önskad avkylning. Det beräknade massflödet som pump och värmeväxlare dimensionerats efter är 2 - 9 kg/s.</p><p>Återbetalningstiden för den investering som behövs för att bygga systemet har beräknats. Om detaljerna från den mekaniska pressen värmeåtervinns återbetalar sig systemet på ca 20 månader. Värmeåtervinning från hela produktionen resulterar i en återbetalningstid på ca 7 månader.</p><br><p>Abstract</p><p>This diploma work is performed in cooperation with Componenta Wirsbo AB. Componenta are a company specialized in forging parts for the vehicle industry. The company uses drop forging where the material is moulded through hammering by two separated tools. Forged material has very good tensile properties and a very homogenous structure. The environmental goal for the company is to reduce their heating energy with 5%. Componenta are also involved in a Lean project to obtain a more continuous production. The suggested heat recycling system will also shorten the cooling time for the products and thereby contribute to a more non-stop production. The goal of this diploma work is to dimension a system for heat recycling of the cooling water from the forged details. The heated water can then be used for hot water and heating.</p><p>For dimensioning the system practically testing was performed. In these test's baskets with forged details was dipped in water and the temperature changes on the details and the water was measured. The results from these testes showed that it is possible to extract approximately 65 kWh of energy from each basket. With heat recycling of the details from the mechanical press it is possible to cover the total need of hot water for the company. If the Componenta decides to heat recycle the total production it is possible to cover the hot water need and about 50 % of the heating. The practical testing showed that the baskets needed about 4 – 6 minutes in the water to obtain the desired cooling effect. The pump and the heat exchanger are dimensioned for a flow of 2-9 kg/s.</p><p>The payoff time for this investment has been calculated. If the company heat recycles the details from the mechanical press the payoff time will be approximately 20 months. Heat recycling of the whole productions will reduce the payoff time too approximately 7 months.</p>
APA, Harvard, Vancouver, ISO, and other styles
14

Rask, Kristoffer. "Värmeåtervinning ur spillvatten : En utredning av möjligheterna med spillvattenvärmeväxlare." Thesis, Högskolan i Gävle, Avdelningen för bygg- energi- och miljöteknik, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-12440.

Full text
Abstract:
The purpose of this report is to investigate the possibilities with drain water heat recovery (DWHR) in residential buildings. Information and relevant theory has been collected and summarized in this report. Calculations have been done for given scenarios to evaluate profits. DWHR heat exchangers use simple technology and have long life-time. The heat exchanger is connected to outgoing drainage pipe and incoming cold-water supply so countercurrent flow is accomplished. This makes it possible to increase the temperature of the incoming cold-water and thereby decrease the amount of energy used to heat water. There are mainly two types of models on the markets, vertically and horizontally heat exchangers. DWHR can be cost-effective if installed during new constructions or renovation, otherwise installation costs can be quite expensive. An installation of a DWHR-unit means no increasing risks of bacteria growth (legionella). Approximately 20 % of the energy used to heat hot-water can be counted as internal heat gain, with a DWHR heat exchanger the amount increases which will result in less energy consumed in the room heating system. More development of existing models is required to reduce the prices and spread information. A big advantage with DWHR is that the energy need for heating water is quite constant during the whole year compared to other demands, for example room-heating. Results from calculations in this report show that a reduction of 43 % of the heating demand for hot-water could be made in a normal family house and 17 % reduction could be made in a residential building with fifty apartments.<br>Syftet med arbetet är att undersöka möjligheterna med att återvinna värme från spillvatten i bostäder. Fakta och relevant teori inom området har samlats ihop och sammanfattats i denna rapport. Egna beräkningar har gjorts för att utvärdera hur mycket det är möjligt att återvinna. Tekniken för spillvattenvärmeväxling är enkel och växlarna håller i regel länge och kräver inget underhåll. En spillvattenvärmeväxlare kopplas in så att motströmsvärmeväxling uppnås. En växlare ansluts till utgående spillvattenledning och inkommande kallvattenledning. Ett problem är att de större växlarna för flerbostadshus kan vara platskrävanade och dyra. En installation av en växlare lämpar sig bäst vid nybyggnation för både småhus och flerbostadshus. Vid renoveringar av miljonprogrammen som uppfördes på 1960–70-tal finns det goda möjligheter att installera spillvattenvärmeväxlare då man genom exempelvis en stamrenovering gör ingrepp på befintliga ledningar, detta kan minska installationskostnaderna. Det finns inga tillkommande risker för legionellabakterier med spillvattenvärmeväxlare. Mer utveckling borde ske inom området så att nya modeller tillkommer. För nuvarande är den vertikala växlaren liten och passar bäst i småhus medan den horisontella växlaren passar bättre vid större anläggningar, med utveckling kan modellerna anpassas så de kan fungera oavsett användningsområde. I småhus bör man i första hand titta på andra åtgärder att för att minska energiförbrukningen, exempelvis driftoptimering, tätning av fönster, tilläggsisolering av vind m.m. En spillvattenvärmeväxlare kan istället vara ett alternativ för ett lågenergihus eller passivhus där vanliga åtgärder redan vidtagits. Ungefär 20 % av energiåtgången för tappvarmvatten kan tillgodoräknas som internvärme, med en installerad spillvattenvärmeväxlare ökar denna del vilket är bra då mindre effekt krävs till värmesystemet. En stor fördel som kan ses med spillvattenvärmeväxling är att tappvarmvattenförbrukningen är relativt konstant under året till skillnad från exempelvis värmebehovet. Utifrån givna scenarion visade beräkningarna i denna rapport att 43 % kunde besparas i småhus och 17 % i flerbostadshus.
APA, Harvard, Vancouver, ISO, and other styles
15

Vidar, Caroline. "Värmeåtervinning på förskolan Rymdattacken 1 : En jämförelse av värmeväxlare." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-96410.

Full text
Abstract:
In the spring of 2014 Sweco Systems AB were commissioned to design a ventilation system for a newly built preschool in Linköping. Terms from the client was that it cost efficiency would cope with the energy demands that are placed on the building. The unit chosen was a cross-flow heat exchanger, and this work is to compare it with two other heat exchangers to see if a more energy and cost efficient could have been chosen. The heat exchangers that was chosen for the comparison was a rotating- and a counterflow heat exchanger. Simulations have been made to the different heat exchangers by the manufacturers. The values from the simulations are then used to make calculations of the heat exchangers use of energy in Joulin. Even a comparison of temperature efficiencies have been made to see how well the heat recycler is working. To get an economic aspect, the calculation of LCC have been made. This work was in addition to the comparison even to find out about the values that came from the simulations to the original unit consists. It turned out that the temperature efficiency shown in these simulations was calculated at a different temperature than the other heat exchangers so it showed a higher percentage than if it had been shown for the same temperature as the other units showed in their simulation. Thus, a calculation of the temperature efficiency for the same temperature in order to make a fair comparison. After studying the different values it was concluded that a rotating heat exchanger should have been chosen instead of the original cross-flow heat exchanger.
APA, Harvard, Vancouver, ISO, and other styles
16

Olsson, Johan. "Optimerande av gasanläggning : genom värmeåtervinning och förlustreducering. Gässlösa Reningsverk." Thesis, Högskolan i Borås, Institutionen Ingenjörshögskolan, 2008. http://urn.kb.se/resolve?urn=urn:nbn:se:hb:diva-18692.

Full text
Abstract:
The municipality, of Gatukontoret in Local government of Borås has in the long run, a required need to look after the current heating devices (the gas production plant) in sewage treatment plant, called Gässlösa. The practical work of the examination is about, trying to find a better way to take care of the current heat recovery. That may be one way or another, rather easy to implement in the existent construction.Through the work to increase the efficiency of the gas engine, implement of some external cooling system by heating exchange device. That gives an opportunity to heat (primary) the digester, (but even all internal public areas) with its own superfluous heating.The report shows that if the management group may invest 422 704 crown to implement a heat exchanging device, it gives more space to reduce the need to buy expensive external energy. Gatukontoret´s pay off time, for buying machines, is 20 years, with reservation to calculate with 4 percent internal interest, leads to the yearly mount of 31103 crowns.If Gässlösa increases the gas engine time in (effective) duty approximately (correspondingly) 48 hours a month the entire investment will generate a profit in January in year seven after the implementations. The amount of profit should therefore be 1 033 337 crowns after 20 years.<br>Uppsatsnivå: C
APA, Harvard, Vancouver, ISO, and other styles
17

Mazraeh, Hifa, and Abdiaziz Abdullahi. "Värmeåtervinning ur spillvatten för flerbostadshus : Kornstigen 25 i Borlänge." Thesis, Högskolan Dalarna, Energiteknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:du-28166.

Full text
Abstract:
Syftet med detta arbete är att sammanställa kunskap om värmeåtervinningssystem för spillvatten i flerbostadshus från litteratur, tidigare studier och relevanta aktörer för ämnesområdet. Syftet är också att göra temperaturmätningar i ett flerbostadshus i Borlänge för att beräkna och analysera energibesparingspotential för Ekoflow värmeväxlaren från Isaksson Rostfria AB. Ekoflow är en spillvattenvärmeväxlare som återvinner värmeenergi ur spillvattnet. Genom spillvattenvärmeväxlare strömmas spillvattnet från avloppet och kallt vattnet i motströmriktningen. Ekoflow har monterats i vissa badhus och hotell och visade bra återvinningsgrader i dessa byggnader. Det är lite svårt att hitta en temperaturmätare på marknaden som kan mäta och lagra mätvärden på en vertikal avloppsstam, därför tillverkades en egen avloppstemperaturmätare som användes för att samla in mätdata för analysering och beräkning av avloppsvärmeförluster. Tillämpningen av tekniken i referensbyggnaden tillför vissa problem. ett problem är att både grå och svartvatten går igenom samma rör vilket minskar temperaturen för spillvattnet. Ett annat problem är att flerbostadshuset inte har någon gemensam anslutningspunkt till den kommunala avloppsledningen, vilket innebär att det kommer att behövas en avloppsvärmeväxlaren för varje stamledning. Energianvändningen i flerbostadshus varierar beroende på boarean och antal boende i huset. Antal boende i referensbyggnaden är inte känt men vattenflödets-och spillvattnets temperaturmätningar visade att byggnaden har hög varmvattenförbrukning. Energibesparingen är beroende av flera parametrar som inkommande kall- och spillvattentemperatur till spillvattenvärmeväxlare samt längden av värmeväxlaren. Energibesparingen för tre olika längder på Ekoflow värmeväxlaren beräknades och en 48 meters värmeväxlare visade energibesparing som ligger på ca. 40 MWh/år vilket motsvarar 24% av varmvattenbehovet i fastigheten. Detta förutsätter att avloppsledningarna kan sammankopplas till en gemensam anslutningspunkt i källarplanet.<br>The purpose of this work is to compile knowledge of waste water recovery systems in multi-family houses from literature, previous studies and relevant actors on the subject area. The purpose is also to make temperature measurements in a multi-family house in Borlänge to calculate and analyze the energy saving potential of the Ekoflow heat exchanger from Isaksson Rostfria AB. Ekoflow is a waste water heat exchanger that recycles heat energy from wastewater. Through wastewater heat exchanger, the waste water flows from the drain and the cold water in the countercurrent direction. Ekoflow has been installed in some bath houses and hotels and showed good recovery rates in these areas. It is a little difficult to find a temperature meter on the market that can measure and store the measured values of a vertical drainage stream. Therefore, produced own temperature meter, which was used to collect measurement data for analysis and calculation of the results. Application of the technology in the reference building adds some problems. One problem is that both gray and black water pass through the same pipe which reduces the temperature of the waste water. The second problem is that the building does not have a common connection point to the municipal sewers, which means that a heat exchanger will be needed for each main line. Energy consumption in multi-family houses varies depending on the living space and number of residents in the house. The number of residents in the reference building is not known but the temperature and water flow and spill water temperature measurements showed that the building has high hot water consumption. Energy saving depends on several parameters such as incoming cold and waste water temperature to waste water heat exchanger and the length of heat exchanger. The energy savings for three different lengths of the Ekoflow heat exchanger were calculated and a 48-meter heat exchanger showed energy savings of approximately 40 MWh / year, which is profitable from the energy saving perspective.
APA, Harvard, Vancouver, ISO, and other styles
18

Oldmark, Anna. "Energieffektivisering av maskinsalsventilation : Utredning av nuläget och utvärdering av åtgärdsförslag." Thesis, Karlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013), 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-36448.

Full text
Abstract:
Stora Enso, Skoghalls bruk är en av världens största producenter av livsmedelskartong och tillverkar ca 700 000 ton per år. Pappers- och massatillverkning är en energikrävande industri och det finns stort intresse att sänka energianvändningen i olika processer. Maskinsalsventilationen på kartongmaskinen KM8 är utrustad med ett värmeåtervinningssystem som tar tillvara på överskottsenergi från pappersmaskinens torkparti. Denna energi används sedan för att förvärma tilluften till maskinalen. På grund av att styrningen och driften inte fungerar optimalt idag måste energi tillsättas från ett ångbatteri.Målet med denna studie var att utreda systemet i dagsläget i form av mass- och energibalanser för sommaren och vintern. Som referens i utredningen användes den beräknade totala ång-användningen över ett år.Utifrån kartläggningen togs åtgärdsförslag fram med syfte att sänka ånganvändningen i systemet som sedan utvärderades. De åtgärder som studerades var att ändra börvärdestemperaturen på glykolflödet, variera glykolflödet, sänka luftflödet i maskinsalen under driftstopp, sänka luftflödet i maskinsalen under vintern samt att installera en ackumulatortank.Resultatet visar att ånganvändningen i systemet kan sänkas med 72 % vilket innebär en besparing på 1,2 miljoner kronor per år utan att någon investering behöver göras. Den mest effektiva åtgärden var att använda en börvärdestemperatur i glykolsystemet som varierar med utetemperaturen. Att installera en ackumulatortank i systemet för att sänka ånganvändningen visade sig inte vara lönsamt och föreslås därför inte som åtgärd.<br>Stora Enso, Skoghall’s mill is one of the largest producers of consumer board in the world and produces approximately 700 000 metric tons per year. Pulp- and paper manufacturing is an energy demanding industry and there is a large interest in lowering the energy use in different processes.The machine hall ventilation system at board machine KM8 is equipped with a heat recovery system which utilizes the excess energy from the machine’s dryer section. This energy is used to preheat the supply air to the machine hall. As a result of inaccurate control and operation, the system is not working at its optimum today and energy has to be added from a steam battery.The aim of this study is to investigate the system in its current state in terms of energy and mass balances during both the summer and the winter. The calculated energy derived from steam was used as a reference in this investigation.Based on the investigation, different proposals of action were made in order to lower the use of steam in the system. The proposals were evaluated in terms of saved energy and costs. The proposals evaluated were to change the set point of the temperature in the glycol system, change the flow in the glycol system, change the air flow in the machine hall ventilation system when the paper machine is not in use, lower the air flow in the machine hall during the winter and to install a storage tank.The result of the study showed that the steam use in the system could be lowered by 72 % which means a saving by 1.2 million SEK annually without any investment cost. De most effective proposal was to change the set point for the temperature in the glycol system so that it’s depending on the outside temperature. Installing a storage tank in order to lower the steam use is not profitable and is not proposed.
APA, Harvard, Vancouver, ISO, and other styles
19

Arlestrand, Oscar. "Energieffektivisering av kvalmgasåtervinning vid Barilla i Filipstad : Energikartläggning och åtgärdsförslag för en lägre energiförbrukning på Västra fabriken." Thesis, Karlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013), 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-36311.

Full text
Abstract:
EU har som mål att år 2020 ha en 20 % lägre energiförbrukning jämfört med den prognostiserade användningen år 2020 (EU-upplysningen 2014). Ett företag som strävar efter att reducera sin energiförbrukning är Barilla i Filipstad som bedriver en bageriindustri där Wasa knäckebröd tillverkas. Vid bakningssteget förbrukas vanligtvis den största energin för bageriindustrier och kan stå för 66 % av den totala energiförbrukningen (Therkelsen et. al 2014). För att sänka denna energiförbrukning har Barilla värmeåtervinningssystem som tar tillvara på en del av energin i den kvalmgas[1] som sugs ut ur ugnen i bakningssteget. Detta sker genom att kvalmgasen duschas av kallare vätska i skrubbrar, vilket medför att vätskan värms upp och den värmeväxlas mot de lokala värmesystemen på fabriken. Den utvunna energin ersätter energibehoven från fabrikens elpanna eller oljepannor. De kallar denna process för kvalmgasåtervinning och den tillgodoser en stor del av det årliga energibehovet. Om det gick att erhålla mer energi ur kvalmgaserna innan de lämnar skorstenarna kunde en mer hållbar brödproduktion uppnås till följd av det lägre energianvändandet av både olja och el. Målet med denna studie var därmed att undersöka om kvalmgasåtervinningen på två av fabrikens produktionslinor kan effektiviseras sett ur ett energi- och miljöperspektiv. Studiens resultat visar att det finns flera åtgärdsförslag som skulle medföra att mer energi kan erhållas ifrån kvalmgasåtervinningssystemen jämfört med rådande konfiguration. Detta energitillskott skulle innebära lägre driftkostnader för Barilla samt en reduktion av bränslebehov och koldioxidutsläpp sett ur ett bredare energiperspektiv. Genom att införa värmeväxling mellan skrubbervattnet på produktionslina 18 och det lokala värmesystemet VS6 skulle driftkostnaden reduceras med 1488 kSEK/år. Om hänsyn tas till den olja som Barilla slipper elda samt att den frigjorda elen ses som marginalel skulle 3765 MWh bränsle/år och 1261 ton CO2/år kunna reduceras via denna åtgärd. Via nuvärdesmetoden beräknades den maximala investeringspotentialen till 18,27 MSEK för detta åtgärdsförslag. Studien har gjorts genom att utföra en kartläggning av samtliga energi- och masstransporter som de två kvalmgasåtervinningssystemen inkluderar. En dynamisk modell har skapats utifrån dessa balanser med hjälp av programvaran SIMULINK. Modellen konstruerades så att den beräknade ett årsbehov av energi ifrån el och oljepannorna som överensstämde med statistik angående energianvändningen 2014. I denna modell skapades också funktioner som kunde simulera konsekvenserna av att införa sju olika individuella åtgärder samt sex kombinationer av dessa. Studien åskådliggör att det finns goda investeringsmöjligheter för att uppnå en mer hållbar brödproduktion. Gjorda känslighetsanalyser visar dock på att resultatens tillförlitlighet berörs av majoriteten av den uppskattning av data som gjorts. För att resultaten skall kunna anses vara mer precisa än kvalificerade gissningar krävs bättre indata i form av medelvärden baserade på loggade värden och mer information om de komponenter som används i systemet. [1] Kvalmgas är ett samlingsnamn för den vattenånga som drivs ut, den luft som används för att driva med sig vattenångan samt den koldioxid som bildas under bakningsprocessen.<br>The EU aims to have a 20% lower power consumption compared to the forecasted usage by 2020 (EU-upplysningen 2014). A company that strives to reduce its power consumption is Barilla in Filipstad who conducts a bakery industry where Wasa crisp bread is manufactured. The baking stage is usually where most energy is required for bakery industries and could account for 66% of the total energy usage (Therkelsen et. al in 2014). To reduce this energy usage, Barilla uses a heat recovery system which extracts some of the energy in the fume gases[1] which are sucked out of the ovens in the baking step. This is accomplished by showering the hot gases with a colder fluid in a scrubber, which then heats up and can be transferred by a heat exchanger to the local heating systems at the factory. The extracted energy replaces energy needs from the plant's electric boiler or oil furnaces. They call this process fume gas recycling and it provides a major part of the annual energy demand. If it was possible to obtain more energy from the fume gases before they leave the chimneys, a more sustainable production of bread be could be achieved due to the lower energy usage of both oil and electricity. The objective of this study was to investigate whether the fume gas recycling on two of the plant's production lines work can be more efficient from an energy and environmental point of view. The results of the study show that there are several measures that would allow the fume gas recycling to give more energy compared to the current configuration. This would mean lower operating costs for Barilla but also a reduction of fuel demands and carbon emissions seen from a broader energy perspective. By introducing a heat exchanger between the scrubber water at production line 18 and the local heating system VS6, operating cost would be reduced with 1488 kSEK/year. If account is taken to the amount of oil that Barilla doesn’t need to burn and if the released electricity that is no longer required is seen as electricity at the margin. A total of 3765 MWh fuel/year and 1261 tonnes CO2/year could be reduced with this measure. By using the present value method the lifetime cost was calculated to 18,27 MSEK. This means that investment costs should be less than this value in order to provide greater or equal revenue than expenditure. The study was done by conducting a survey of all energy and mass transport that the two fume gas recycling systems include. A dynamic model was created based on these balances by using SIMULINK software. The model was configured so that the calculated energy needs from electricity and oil furnaces was the same as the statistics on energy use from 2014.  The capability to simulate the effects of introducing seven different individual actions and six combinations of these were also added to this model. The study illustrates that there are good investment opportunities in order to achieve a more sustainable production of bread. Sensitivity analyses that were implemented in the study show, however, that the validity of the results is affected by a majority of the evaluated data. Input data in the form of averages based on logged values and more information about the components used in the system are required to obtain results that are to be considered more precise than educated guesses. [1] Fume gases is a generic term for the water vapor that is driven out, the air that is used to carry the water vapour and the carbon dioxide produced during the baking process.
APA, Harvard, Vancouver, ISO, and other styles
20

Åleheim, Jennie. "Återvinning och energieffektivisering av varukylanläggningar." Thesis, Linnéuniversitetet, Institutionen för byggd miljö och energiteknik (BET), 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-36716.

Full text
Abstract:
Denna studie undersöker möjligheten till värmeåtervinning och energieffektivisering av mindre varukylanläggningar genom en fallstudie. Värmeåtervinning visade sig mest lönsam, med hänsyn till energivinst, investeringskostnad samt återbetalningstid, från en anläggning med ett direkt expansionssystem. Anläggningen kompletteras med en kondensorväxlare och en sekundärkrets för ackumulering av värme i ackumulatortankar. Varvtalsregleringen visar sig vara mycket lönsam med hänsyn till behovet av tillförd elenergi, jämfört med en anläggning med konstant varvtal, även vid fullast. Dock minskar driftsäkerheten av anläggningen.
APA, Harvard, Vancouver, ISO, and other styles
21

Fredlund, Markus, and Markus Olsson. "Jämförande undersökning av värmeåtervinning ur frånluft i två flerbostadshus med frånluftvärmepumpar." Thesis, KTH, Byggteknik och design, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-101670.

Full text
Abstract:
Två olika värmesystem i två flerbostadshus har analyserats. Målet med analysen är att få en uppfattning om vilket värmesystem som är mest fördelaktigt i flerbostadshus. I analysen jämförs två olika värmesystem. I värmesystemen används två olika sorters frånluftsvärmepumpar för att återvinna värme ur frånluften. När värmepumparna inte klarar av att producera tillräckligt med värme för att täcka fastighetens värmebehov används fjärrvärme som spetsning. Värmepumparna är fastighetens huvudvärmekälla. I den ena fastigheten, Gäddan 1, används en luft-vatten frånluftvärmepump. Kylbatteriet som finns i frånluftsvärmepumpen är placerat i frånluftkammaren. Den andra fastigheten, Gäddan 2, använder sig av två utomhusvärmepumpar. Dessa två är placerade i en frånluftskammare för att kunna återvinna den varma luften.  Under analysen har en sammanställning av egna mätningar och prognoser tagits fram ur en mätningsperiod på tre veckor. I analysen jämförs de olika värmesystemen utifrån tre olika faktorer; energi, miljö och ekonomi. De parametrar som beräknats är värmefaktor (COP), energiförbrukning (kWh), livscykelkostnad (LCC), återbetalningstid (år) och kostnad för producerad värmeenergi (kr/kWh). Resultaten utgår från statistiken och jämförs mellan varandra. Resultatet av analysen visar att värmesystemet i fastigheten Gäddan 1 är mest fördelaktig enligt de metoder som har använts som berör både energi och ekonomi.  Det resultat som visats är att Gäddan 1 har 20 % högre värmefaktor, 12 % lägre driftskostnad och 50 % snabbare återbetalningstid för värmesystemet. Dock har värmesystemet 36 % högre koldioxidsutsläpp under systemets levnadslängd, som är baserat på 20 år.  I slutsatsen kan fastigheternas storlek påverka resultaten. Gäddan 1 är en större byggnad och har fler lägenheter jämfört med Gäddan 2. Detta påverkar förbrukningen av fjärrvärme i värmesystemen som ökar koldioxidsutsläppen, vilket kan vara en bidragande faktor till att Gäddan 1 har högre koldioxidsutsläpps resultat (36 %) än Gäddan 2.<br>Two different heating systems in two apartment buildings have been analyzed. The goal of this analysis is to get an idea of which heating system is most beneficial in apartment buildings. The analysis compares two different heating systems. Two different kinds of exhaust air heat pumps are used to recover heat from exhaust air. When heat pumps are unable to produce enough heat to cover the heating demand of the buildings, district heating is used. The heat pumps are the property's main source of heat. In one property, Gäddan 1, an air-water heat pump is used. The cooling coil located in the exhaust air heat pump is placed in the exhaust chamber. The other property, Gäddan 2, features two outdoor heat pumps. These two pumps are disposed in an exhaust chamber in order to recover the hot air. During analysis, a compilation of measurements and predictions from a measurement period of three weeks has been analyzed in order to calculate the various parameters. The analysis compares the different heating systems based on three different factors including energy, environment and economy. The parameters that are calculated are the coefficient of performance (COP), energy consumption (kWh), life cycle cost (LCC), payback period (years) and cost of the produced thermal energy (SEK / kWh). The results are based on statistics and compared between each other. The result of the analysis shows that the heating system in the property Gäddan 1 is the most beneficial, according to the methods used concerning both energy and economy. The result shows that Gäddan 1 has a 20 % higher coefficient of performance, 12 % lower operating cost and 50 % faster payback time for the heating system. However, this heating system has 36 % higher carbon dioxide emissions during its life span, which is based on 20 years. In conclusion the properties size may also affect the results. Gäddan 1 is a larger building and has more flats than Gäddan 2. This affects the consumption of district heating in the heating systems with increase carbon emissions. This may be a contributing factor to a higher carbon dioxide emission in Gäddan 1 (36 %) compare to Gäddan 2.
APA, Harvard, Vancouver, ISO, and other styles
22

Alegrim, Georg, and Alexander Anaje. "Värmeåtervinning av luft i kycklingstallar : Återanvändning av energin i frånluften för luftförvärmning." Thesis, Linnéuniversitetet, Sjöfartshögskolan (SJÖ), 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-82239.

Full text
Abstract:
I Sverige har konsumtionen av kyckling per invånare ökat de senaste åren och idag konsumeras 23,2kg per person och år. Eftersom tillväxten för svensk kyckling är hög ökar också medvetenheten hos företag att investera i klimatsmarta alternativ för att minska energibehovet som leder till en minskad uppvärmningskostnad. Det valda djurstallet värms upp med en flispanna där vattenburna värmeelement förser stallet med värme längs väggarna. Syftet med studien är att undersöka hur mycket värmeenergi som går att spara genom att använda den utsugna luften för att värma den luften som sugs in med hjälp av en värmeväxlare. Det har ansetts problematiskt att använda stallets frånluft för att tillgodose energi i form av värme eftersom den oftast är dammig och detta bidrar till att filter och kanaler täpps igen. Idag finns det ett antal luftvärmeväxlare som klarar denna typ av damm och partiklar.  Två olika värmeväxlare har jämförts, en rekuperativ (plattvärmeväxlare) och en regenerativ (roterande värmeväxlare). Stallet måste hålla ett lågt CO2 värde och kycklingarnas ströbädd måste hållas torr med hjälp av en låg luftfuktighet. Ventilationens volymflöde är ett beräknat teoretiskt värde. Resultatet av de två jämförda värmeväxlarna visar att den regenerativa (roterande) värmeväxlaren återför fukt vilket som bidrar till en fuktigare ströbädd jämfört med den rekuperativa (plattvärmeväxlare) som inte återför fukt. Studien genomfördes under kycklingarnas uppfödningstid, vilket varade från första januari i 34 dagar framåt. Dag 28–30 blir stallet självförsörjande på värme och värmeväxlaren kan då generera den värmen som krävs utan anläggningens tillhörande flispanna. Med hänsyn till skallklimatet är det att föredra en plattvärmeväxlare då den roterande värmeväxlaren återför vatten av tre gram per kg torr luft. Undersökningen visar det totala värmebehovet, som idag är cirka 48,2 MWh under en uppfödningsomgång, kan minskas med 24,8 MWh med hjälp av en värmeväxlare under denna omgång.<br>The consumption of chicken per inhabitant have increased in Sweden the last couple of years and today 23,2 kg is consumed per inhabitant and year. Because of this rise of Swedish chicken consumption, the awareness of investing in climate-smart alternatives have increased by the companies. The companies are decreasing the energy required during production, which ultimately leads to a reduced heating cost. The animal stall is heated by a boiler where water-based heating elements are providing the animal stall with heat along the walls.  It has been considered problematic to heat up the animal stall by reintroducing the air from inside the stall due to the fact that this air often is too dusty, which contributes to blockage of filters and ducts. There are a number of different heat exchangers that can handle this kind of dust and particles today.  Two different heat exchangers will be compared, a recuperative plate heat exchanger and a regenerative rotary heat exchanger. The animal stall must keep a low CO2 value and it is important to keep the chickens bedding dry by a low humidity inside the stall. The study shows that the total heat for one breeding round, which today is approximately 48,2MWh, which equals a saving by using an air heat exchanger of 24,8MWh. The result of the comparison of the two heat exchangers has shown that the regenerative (rotary) heat exchanger reintroduces moisture in the stall, which the recuperative (plate heat exchanger) does not. The follow up for this study was 34 days, from the chickens’ birth to the slaughter. During day 28-30 the animal stall becomes self-sufficient considering heat, which means that the heat exchanger could generate the heat required for the facility without the use of the stalls chip boiler. The study is implemented with a calculated volume flow due to a short outlet channel on the system, this can lead to a risk of a minor faulty value. Regard to the humidity in the stall, it is preferable to use a plate heat exchanger as the rotating heat exchanger precipitates water of 3 grams/kg of dry air.
APA, Harvard, Vancouver, ISO, and other styles
23

Eriksson, Viktor. "Energikartläggning av ett mjukpappersbruk : Värmeåtervinning som alternativ till ånga för uppvärmning av lokaler." Thesis, Karlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013), 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-45444.

Full text
Abstract:
Massa- och pappersindustrin i Sverige stod för 51 % av den svenska industrisektorns totala energianvändning år 2015. Det gör det extra viktigt för svenska massa- och pappersbruk att dokumentera sin energianvändning med jämna mellanrum för att identifiera var och hur energin används, en så kallad energikartläggning. På så vis kan brister i systemet identifieras och eventuella åtgärder sedan tas fram. Denna studie utfördes på Katrinefors bruk som är placerat i Mariestad och är ett av tre mjukpappersbruk som koncernen Metsä Group har i Sverige. På Katrinefors bruk används både returfibrer och nya träfibrer för att producera mjukpapper i form av bland annat toalett- och hushållspapper. En energikartläggning av Katrinefors bruk utfördes där brukets totala energianvändning år 2015 identifierades genom att analysera Excel dokument som bruket använder för att dokumentera sin energianvändning. Vidare studerades värmeåtervinningen av den våta luften från en av pappersmaskinernas yankeekåpa för att ta reda på om ytterligare energi skulle kunna hämtas ur en av värmeväxlarna för användning i uppvärmningssystemet. Massbalanser över yankeekåpan ställdes upp för att identifiera massflödet av luft och luftens vatteninnehåll. Energi- och massbalanser tillsammans med temperaturmätningar användes för att identifiera energiinnehållet i luften vid olika steg i värmeåtervinningsprocessen. Beräkningar utfördes för hur mycket vatten som skulle krävas för att befukta luften till mättat tillstånd. Det antogs att om luften gjordes mättad på vatten skulle kondensationen öka i efterliggande värmeväxlare och på så vis skulle värmeöverföringen också öka. Energikartläggningen visade att pappersmaskinerna och avsvärtningsanläggningen var brukets stora energianvändare. Energikartläggningen visar också att förbättringar gällande energianvändningen på bruket utförts sedan 2010 med en stadigt minskande energianvändning per ton producerat papper per år. Resultaten från beräkningarna gällande värmeåtervinningen visar att energiinnehållet i luften skulle räcka för att täcka uppvärmningen av samtliga byggnader. Resultaten visar dock också att värmeväxlaren som studerades troligtvis inte är tillräckligt stor utan den skulle behöva kompletteras eller bytas mot en ny värmeväxlare. Åtgärderna framtagna i denna studie skulle fortfarande vara möjliga att implementera utan att komplettera eller byta ut den befintliga värmeväxlaren. Då krävs en fortsatt studie som undersöker värmebehovet byggnad för byggnad för att ta reda på om en del av den totala uppvärmningen skulle kunna täckas av de åtgärder som presenteras i denna studie.<br>The pulp and paper industry in Sweden accounted for 51% of the Swedish industrial sector's total energy consumption in 2015. This makes it particularly important for the Swedish pulp and paper industries to document their energy on a regular basis to identify where and how energy is used, a so-called energy audit. This allows for the weaknesses in the system to be identified and measures to fix them can then be developed. This study was performed on Katrinefors mill, which is located in Mariestad and is one of three tissue mill that the group Metsä Group has in Sweden. Katrinefors mill uses both recycled fiber and virgin wood fibers to produce tissue paper in the form of toilet paper and paper towels among others. An energy audit on Katrinefors mill was performed where the mill's total energy consumption in 2015 was identified by analyzing Excel documents used by the mill to document their energy usage. The heat recovery system for the wet air from one of the paper machines Yankee hoods was also studied to see if additional energy could be extracted from one of the heat exchangers for use in the heating system. The mass flow of air and water through the Yankee hood was calculated using mass balances. The energy content in the air at different positions in the heat recovery system was established using energy- and mass balance calculations together with dry- and wet bulb temperature measurements. Calculations were performed for the amount of water that would be required to humidify the air to a saturated state. It was assumed that if the air were to be saturated that the heat transfer in the heat exchanger would increase due to a higher rate of condensation. The energy audit showed that the paper machines and deinking plant was the mill's largest energy users. It also showed that the improvements made at the mill since 2010 have led to a steadily declining energy usage per ton of paper produced per year. The results of the calculations regarding the heat recovery shows that the energy content of the air would suffice to cover the heating of all buildings that otherwise would rely on steam. The results show, however, that the heat exchanger studied probably is not big enough and that it would need to be supplemented or replaced by a new heat exchanger. The actions developed in this study could still be possible to implement without supplementing or replacing the existing heat exchanger. This requires a further study investigating the heating requirements for the each building individually to see if a portion of the total heating could be covered by the measures presented in this study.
APA, Harvard, Vancouver, ISO, and other styles
24

Jonell, Magnus, and Robin Kairis. "Torkventilation vid kartongtillverkning : En fallstudie på Fiskeby Board AB." Thesis, Linköpings universitet, Energisystem, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-94534.

Full text
Abstract:
Pappers- och massaindustrin stod år 2010 för 52 procent av den svenska industrins energianvändning, vilket motsvarade 76 TWh. Detta gör branschen intressant ur ett energieffektiviseringsperspektiv då små åtgärder kan leda till stora besparingar. Fiskeby Board AB är ett företag som tillverkar kartong baserad på returfiber. Då torkning- samt bestrykningsprocessen står för 2/3 av företagets energibehov föreligger intresse att använda energin på ett bättre sätt för att minska energibehovet och därav minska sina kostnader. Syftet med denna rapport var således att genomföra en energikartläggning av tork- samt bestrykningspartiet och utifrån resultaten presentera åtgärder för att minska energibehovet. Arbetet utfördes genom mätningar av lufttemperaturer och flöden, beräkningar, litteraturstudier samt intervjuer. De ytvikter som undersöktes var för vinterdrift 300 g/m2, 350 g/m2 samt 450 g/m2 och för sommardrift 450 g/m2. Resultaten visade att inläckaget till torkkåpan, som rekommenderas till 25 procent av totalt inflöde, var mellan 48 och 59 procent. Vidare påvisades även hypotesen om att det i regel används större mängd luft för att transportera bort vattnet från kartongen än vad som krävs. Detta på grund av att det inte finns någon reglering av värmeåtervinningsaggregatens fläktar, vilket medför att frånluften får ett lågt vatteninnehåll vid viss produktion. Ett annat viktigt resultat behandlar hetluftsystemet. Här bör ett visst undertryck föreligga i hetluftskåporna, men genomförda mätningar visade på att enbart en av tre hetluftskåpor erhöll detta undertryck. Åtgärdsförslagen som presenteras i rapporten behandlar bland annat de påträffade bristerna ovan. Ett förslag är att minska det våta frånluftsflödet samtidigt som den inläckande luften bör ersättas med redan uppvärmd luft från andra delar av anläggningen. Enligt förslaget kan detta göras genom att nyttja frekvensstyrda till- och frånluftsfläktar vilka styrs av frånluftens daggpunktstemperatur och nollnivån i torkkåpan. Denna lösning har potential att minska den årliga energianvändningen med 17,9 GWh vilket kan ge en kostnadsbesparing av 2,25 miljoner SEK per år. Ett annat åtgärdsförslag är att ta bort förbigångsventilerna till värmeåtervinningsaggregaten och låta ångtillförseln styras med enbart reglerventiler. Detta ger en potential att minska energibehovet med 0,47-0,64 GWh per år vilket skulle ge en kostnadsbesparing av 55 000-77 000 SEK per år. För hetluftsystemet finns potential att spara 0,64 GWh vilket skulle ge en kostnadsbesparing på 77 000 SEK per år. Det som behövs är ett manuellt reglerspjäll i kanalen från hetluftskåpa 1 alternativt hetluftskåpa 2, för att styra luftflödet och därav erhålla ett undertryck i systemet. Genom att sammanställa de tre mest rekommenderade åtgärdsförslagen skapas en möjlighet att spara 5,7 procent av Fiskeby Board ABs energibehov vilket skulle resultera i en årlig kostnadsreduktion av 2,41 miljoner SEK. Om en generalisering att även den övriga pappers- och massaindustrin besitter liknande potential finns möjlighet för denna bransch att årligen minska energianvändningen med 4,4 TWh.
APA, Harvard, Vancouver, ISO, and other styles
25

Mariam, Bel Fdhila, and Qader Daron. "Värmeåtervinning i ventilationsluft : En studie om FX- och FTX-ventilation vid energieffektivisering av flerbostadshus." Thesis, Mälardalens högskola, Akademin för ekonomi, samhälle och teknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-40045.

Full text
Abstract:
To reduce the heating demand and do savings in energy cost of buildings there are several possible actions while renovating. Thru using heat recovering systems in buildings or constructions that are well-insulated the heat demand in buildings gets reduces. Air and supply air systems with heat recovery (FTX) and exhaust air heat pump (FX) are two different ventilation types that can recycle heat in a building. Heat recovery in FTX systems is done with a heat exchanger, while in FX systems it is done by a heat pump. In this degree project, a comparison has been made between the two ventilation systems, FTX and FX, by calculating the energy consumption of a building and their recycling opportunities. Possible energy savings have been calculated and how the profitability of the systems looks. Further, the actual performance of the FTX system is investigated and if it complies with the currently reported temperature efficiency specified by the ventilation manufacturers. Indoor air is used as a heat source when it is taken out of the building and is called exhaust air, energy is then recycled from the hot exhaust air. Exhaust air is hot because it contains indoor temperature. If heat recovery does not occur, the heat in the extract air is vented out of the housing, which means that the heat energy is lost. The energy calculations that gave an answer to how much energy is saved for each system compared to an F system has been performed in Excel and the recovered heat of the systems is calculated for each hour for a whole year and in different parts of the country, such as Kiruna, Stockholm, Örebro and Ystad . Moisture and temperature variation can affect the efficiency and recovery rates of the investigated units, therefore, cities with such geographical depiction have been chosen to be analyzed. The residual heating requirement in the house is supplied by district heating. The result of this study shows that the FTX system brings the greatest cost savings, while the FX system offers the highest energy savings. However, FTX ventilation has a relatively large energy saving in colder climate, which makes the system more competitive with FX with respect to energy savings. Installation costs are slightly lower for FX ventilation compared to FTX ventilation, but the life span of FTX systems is 40 years while it is only 15 years for the FX system. In a short period of time, FX systems can be cheaper, but in the long run, FTX systems become more profitable. Due to the fact that the electricity price is higher in relation to the price paid for district heat, energy savings in FX systems can not lead to cost savings. This means that the heat pump already has no economic competitiveness at many locations in the country today. According to the building rules of the building, real estate is to be calculated by 85% after the introduction of primary energy factor, which is 1.85 for electricity in a few years, which means that FX systems will not become more competitive even in energy use against the FTX system. This means that FTX systems should stand as an obvious choice of ventilation in the future. The current temperature efficiency of FTX systems can be replaced by an energy efficiency rate, which might be more accurate measure of recycled amount of energy. The energy efficiency could therefore be introduced to avoid that more energy than expected is actually needed in the energy use of the house.<br>För att minska uppvärmningsbehovet och energikostnader i byggnader finns det ett flertal olika möjliga åtgärder. Genom att återvinna värme som finns tillgänglig i byggnader eller konstruktioner med välisolerade byggnader minskas värmebehovet i byggnader. Från- och tilluftssystem med värmeåtervinning (FTX) och frånluftvärmepump (FX) är två olika ventilationstyper som kan återvinna värme i en byggnad. Värmeåtervinningen i FTX-system sker med hjälp av en värmeväxlare medan den i FX-system sker med hjälp av en värmepump. I detta examensarbete har en jämförelse gjorts mellan de två ventilationssystemen, FTX och FX, genom att beräkna energiåtgången för en byggnad och återvinningsmöjligheterna. Möjliga energibesparingar har beräknats samt hur lönsamheten för systemen ser ut. Ytterligare undersöks FTX-systemets verkliga prestanda och om denna överensstämmer med den aktuellt redovisade temperaturverkningsgraden som ventilationsfabrikanterna anger. Inomhusluften används som värmekälla då den förs ut ur byggnaden och kallas frånluft, energi återvinns då från den varma frånluften. Frånluft är relativt varm för att den håller inomhustemperatur. Om värmeåtervinning inte sker ventileras värmen i frånluften ut ur bostaden, vilket innebär att värmeenergin går förlorad. Energiberäkningarna som gett svar på hur mycket energi som sparas för respektive system jämfört med ett F-system, har utförts i Excel och systemens återvunna värme beräknas för varje timme under ett helt år och i olika delar av landet, Kiruna, Stockholm, Örebro och Ystad. Fuktigheten och temperaturvariation kan påverka effektiviteten och återvinningsgraden hos de undersökta aggregaten, därför har städer med så geografisk skildring valt att analyseras. Det återstående värmebehovet i huset försörjs av fjärrvärme. Resultatet av denna studie visar att FTX-systemet medför störst kostnadsbesparing, medan FX-systemet för med störst energibesparing. FTX-ventilation har dock en relativ stor energibesparing i kallare klimat, vilket gör systemet mer konkurrenskraftig mot FX med avseende på energibesparingen. Installationskostnaden är något lägre för FX-ventilation jämfört med FTX-ventilation, men livslängden för FTX-system är på 40 år medan den enbart är 15 år för FX-systemet. På kort tid kan FX-system vara billigare, men på lång sikt blir FTX-system mer lönsamt. På grund av att elpriset är högre i förhållande till det pris som betalas för värme kan energibesparing i FX-system inte leda till någon kostnadsbesparing. Detta gör att värmepumpen redan idag inte har någon ekonomisk konkurrenskraft på många platser i landet. Enligt boverkets byggregler ska fastighetsel räknas upp med 85% efter införing av primärenergifaktor, som är 1,85 för el om några år, vilket gör att FX-system ska ha det svårare att konkurrera även energimässigt mot FTX-systemet. Detta innebär att FTX-system ska stå som ett självklart ventilationsval i framtiden. Gällande temperaturverkningsgraden för FTX-system kan en energiverkningsgrad vara ett mer rätt mått på återvunnen mängd energi. Energiverkningsgraden skulle därför kunna införas för att undvika att mer energi än beräknat egentligen åtgår i husets energianvändning.
APA, Harvard, Vancouver, ISO, and other styles
26

Danielsson, Elisabet. "Möjligheter till energieffektivisering genom ökad värmeåtervinning på ett massabruk : Pinchanalys av sulfatmassabruket i Olshammar." Thesis, Karlstads universitet, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-67955.

Full text
Abstract:
Syftet med det här examensarbetet är att undersöka möjligheter för energieffektivisering i form av ökad värmeåtervinning hos Ahlström-Munksjö Aspa Bruk AB med målet att föreslå åtgärder som minskar behovet av färskånga till uppvärmning i processerna. Detta har gjorts med hjälp av en pinchanalys där de externa behoven, pinchöverträdelser och effektiviseringsmöjligheter har identifierats och analyserats för att avgöra hur effektiv värmeväxlingen på Aspa Bruk är. Strömdata har samlats in på plats på bruket främst genom givare som loggar data kontinuerligt men även genom mätningar, miljöbesiktningsrapporter och antaganden.  Ur pinchanalysen framkom det att de externa värmebehoven potentiellt skulle kunna reduceras med ca 19,2 MW, vid ett så energieffektivt system som möjligt, jämfört med dagens behov av färskånga som ligger på 71,5 MW. I praktiken är det dock inte möjligt att genomföra åtgärder för att minska det externa värmebehovet fullständigt till följd av tekniska- och ekonomiska begränsningar. Pinchöverträdelser står för ca 7,7 MW av de ca 19,2 MW och återfinns i sekundärvärmesystemet då det råder överskott av värme i varmvatten- och hetvattenproduktionen.  De åtgärdsförslag som läggs fram bygger på att effektivisera energianvändningen och avlägsna pinchöverträdelser med åtgärder som anses genomförbara. Tre åtgärder presenteras:  Använda värmeenergin från rökgaserna från sodapannan för att förvärma förbränningsluften till sodapannan och därmed ersätta delar av färskångan som används till detta. Öka andelen flashånga från tank 2 till förbasningsfickan där flisen förvärms innan kokaren istället för terpentinkondensorn. Detta skulle medföra en reducering av färskånga till förvärmningen av flisen.  Eliminera 3 bars ångan till hetvattentanken och kompensera med ett ökat varmvattenflöde genom ett ökat intag av råvatten som ska bli varmvatten.  Totalt skulle dessa åtgärder potentiellt kunna minska förbrukningen av färskånga med ca 12,5 MW. Potentiellt skulle även mer ånga kunna sparas om rökgaserna från sodapannan tilläts kondensera. Åtgärdsförslag nummer 3 är den som bidrar mest till reduceringen av färskånga på Ahlstrom-Munksjö Aspa Bruk AB.<br>The purpose of this master’s thesis is to investigate opportunities for a higher energy efficiency in terms of increased heat recovery at Ahlstrom-Munksjö Aspa Bruk AB with the goal of suggesting actions that reduces the need for live steam in process heating. In order to do this a pinch analysis was conducted where the utility consumptions, pinch violations and opportunities for increased energy efficiency were identified and analyzed in order to determine how efficient the heat exchange at Aspa Bruk is. Stream data was gathered at the mill mainly through continuously logging sensor data but also through measurements, environmental inspection reports and assumptions.       From the pinch analysis it was discovered that the external hot utility potentially could be reduced by approximately 19,2 MW given that the system would be as energy efficient as possible, compared to the current need of live steam that is 71,5 MW. However, in reality it is not possible to accomplish this reduction due to technical and economic limitations. Pinch violations stand for about 7,7 MW of the 19,2 MW and are located in the secondary heat system since there is an excess of heat in the warm water- and hot water production.  The actions suggested are based on increasing the efficiency of the energy consumption and removing pinch violations and are also considered feasible. Three suggestions are presented:  Recover the heat in the fumes from the recovery boiler and use it to preheat the combustion air in to the recovery boiler and thereby replace some of the live steam used for this.  Increase the amount of flash steam from tank 2 to the preheating of the woodchips before the boiler by reducing flash steam to the turpentine condenser. This would lead to a reduction in live steam used to preheat the woodchips. Eliminate the 3-bar live steam to the hot water tank and compensate it by increasing the amount of cold water that is going to become warm water.  In total, these proposed arrangements will potentially lead to a reduction in the use of live steam of approximately 12,5 MW. Potentially even more live steam can be saved if the fumes from the recovery boiler are allowed to condense. Number 3 amongst the proposed actions is the one that has the biggest influence on the reduction of live steam at Ahlstrom-Munksjö Aspa Bruk AB.
APA, Harvard, Vancouver, ISO, and other styles
27

Winsjansen, Frida. "Utredning av energibesparingspotential och lönsamhet hos kompressorsystem med värmeåtervinning : För integrering i industriellt uppvärmningssystem." Thesis, Högskolan i Gävle, Avdelningen för bygg- energi- och miljöteknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-27776.

Full text
Abstract:
För att tillgodose framtidens växande behov av energi och samtidigt bidra till en långsiktigt hållbar energitillförsel krävs resurs- och energieffektivisering inom flera sektorer. Inte minst inom industrin som år 2016 stod för mer än 50 procent av det globala energibehovet. Tillvaratagandet av befintliga resurser såsom spillvärme från tryckluftsproduktion är en möjlig effektiviseringsåtgärd. Till grund för examensarbetet ligger ett önskemål från koncernen Sandvik AB att utreda besparingspotential och kostnader för reinvestering i en av industrins kompressorcentraler, Götvalsverket. Reinvesteringen avser två nya kompressorer vars spillvärme integreras i industrins befintliga närvärmesystem och möjliggör för minskade resurs- och energikostnader samt utsläpp av CO2. Arbetet syftar till att analysera olika kompressorlösningar utifrån ett ekonomiskt och miljömässig perspektiv. Detta görs med hjälp av insamlad data, känslighetsanalyser och lönsamhetskalkyler med tillhörande LCC. Målet är att kunna besvara olika frågeställningar rörande total investeringskostnad, energi- och resursbesparing samt utsläppsreducering. Två fall av produktion undersöks, dels vid drift enligt Götvalsverkets befintliga produktionstid och dels med en optimerad drifttid för kompressorenheterna. En litteraturstudie har också genomförts där flera studier visar att tryckluft är ett dyrt alternativ för energiproduktion och att implementering av effektiviseringsåtgärder, däribland återvinning av spillvärme, därför kan vara väl grundade investeringar. Även andra fördelar kan kopplas till energieffektivisering, exempelvis förbättrad produktion och arbetsmiljö för anställda. Resultatet av arbetet visade att särskilt ett kompressoralternativ stod ut från de övriga ur både en ekonomisk- och miljömässig synpunkt. Detta alternativ erbjöd inte den billigaste investeringen men däremot var mängden återvunnen värme så pass mycket större än för andra alternativ, att energibesparingen minskade återbetalningstiden drastiskt. Tillvaratagande av befintliga resurser som spillvärme, tillsammans med industrins minskade energianvändning, anses vara en nödvändighet för att kunna säkerställa välmående hos både människor, djur och natur i framtiden.<br>In order to meet the growing demand for energy in the future, while contributing to a long-term sustainable energy supply, resource and energy efficiency measures are required within several sectors. In 2016 the industry sector accounted for more than 50 percent of the global power demand. The use of existing resources, such as waste heat from compressed air production, is a possible efficiency measure.  Behind this thesis work is a request from the Sandvik AB Group to estimate savings potential and reinvestment costs in one of the industry's compressor centers, Götvalsverket. The reinvestment refers to two new compressors whose waste heat is integrated into the industry's existing district heating system and allows for reduced resource and energy costs as well as a reduction of CO2-emissions.  This work aims to investigate different compressor alternatives from an economic- and environmental perspective. This is done using collected data, a sensitivity analysis and profitability calculations with an attached LCC-analysis. The aim is to answer various questions regarding total investment cost, energy and resource saving as well as emission reduction. Two cases in production are investigated. The first according to the existing operation hours in Götvalsverket and the second case with an optimized operating time for the compressor units.  A literature review has also been conducted where several studies show that compressed air is an expensive alternative to energy production and that implementation of efficiency measures, including waste heat recovery, can be well-founded investments. Other benefits can also be linked to energy efficiency, such as improved production and an improved work environment for employees.  The result of the work showed that one alternative in particular stood out from the other compressor solutions, both from an economic and environmental point of view. This option did not offer the cheapest investment but the amount of recovered waste heat was much larger than for the other alternatives and therefore, energy savings reduced the payback period drastically.  The utilizing of existing resources such as waste heat, together with the industry sector’s reduced energy consumption, is considered a necessity in order to ensure the well-being of people, animals and nature in the future.
APA, Harvard, Vancouver, ISO, and other styles
28

Östin, Ronny, Erik Eklund, and Christer Johansson. "Energieffektivt byggande i kallt klimat." Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2012. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-68737.

Full text
Abstract:
Projektet energieffektivt byggande i kallt klimat är en fältstudie där 6 nybyggda lågenergihus i Umeåregionen utvärderats. Fyra byggnader är villor och två byggnader är flerbostadshus som är lokaliserade från Sikeå i norr till Nordmaling i söder. Byggnaderna har utrustats med trådlös mätutrustning för verifiering av energiprestanda för hela byggnaden ned till komponentnivå. Mätare för fukt och temperatur i luft och klimatskal har också installerats där de senare är placerade på olika djup i konstruktionen. Syftet med studien är att undersöka byggnadernas energiprestanda och vilka risker det finns med att bygga lågenergihus i kallt klimat. Genomförda fukt- och temperaturmätningar i konstruktionen visar idag inga tecken på röt- eller mögelangrepp, dock krävs längre mättid eftersom fukttransport är en långsam process. Baserat på energisignatur har uppmätt energianvändning i byggnaderna normalårskorrigerats och U-medelvärdet beräknats. Dessa värden har jämförts med projekterad energianvändning och U-medelvärde. Två av byggnaderna är utrustade med en markförlagd uteluftskanal, 36 respektive 10 m där den första lösningen visade sig eliminera behovet av eftervärmning av tilluften. Markförvärmning av uteluft är en enkel och effektiv metod för att höja temperaturen på inkomande uteluft, t.ex. vid -25°C värmdes inkommande luft till värmeväxlaren till +2°C. Mätningar av energianvändning visar att det går att bygga hus som använder betydligt mindre energi än boverkets krav på specifik energianvändning. Villorna uppvisar en specifik energianvändning enligt boverkets definition (energi för uppvärmning och tappvarmvatten dividerat med Atemp) från 59,7 till 91,8 kWh/m2, år och flerbostadshusen från 68 till 75,5 kWh/m2, år, vilket är lägre en gällande krav på 130 kWh/m2, år och vid elvärme 95 kWh/m2, år.<br>The project Energy efficient construction in cold climate is a study of six newly produced low energy buildings in the region of Umeå. Four buildings are houses and two residential buildings which are located from Sikeå up north to Nordmaling down south. The buildings have been equipped with wireless logger system for collecting data of energy performance for the entire building and for individual components of the energy system. Loggers for relative humidity and temperature have been placed in ventilation and the buildings construction shell. The later of the position of loggers have been placed in different depths of the constructions isolating shell. The purpose of this study is to investigate these buildings energy performance and what risks constructing energy efficient buildings in cold climate due to humidity. The relative humidity and temperature sensors located in the construction shell show no signs of risk for rotting and mold. Moisture migration is a slow process and to be certain longer measurements are required. With the method called energy signature the measured energy usage have been normal corrected by year and the average U-value calculated. Expected energy usage and average U-value is compared to our measured data in this report. Two buildings in the study are equipped with a buried pipe for supply air which is 36m and 10 m long. The longest (36m) shows a big increase of air temperature (from -25°C outside to +°2 at the inlet connecting to the heat exchanger). This by means no extra heat is required for the inlet air to reach comfortable temperature. The measurement of energy displays that constructing buildings with lower energy use then the Swedish Boverkets requirements are confirmed. The houses shows a specific energy usage as Boverkets definition (energy for heating and for domestic hot water per heated surface area) from 59.7 to 91.8 kWh/m2, year and the residential buildings from 68 to 75.5 kWh/m2, year which are lower than today regulations at 130 kWh/m2, year and 95 kWh/m2, year for electric heated.
APA, Harvard, Vancouver, ISO, and other styles
29

Olofsson, Per. "Simuleringsmodul för energiflödesanalys av ett hybridfordons drivlina." Thesis, Karlstads universitet, Avdelningen för energi-, miljö- och byggteknik, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-33785.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Medina, Jean Pierre, and Zjikar Abdulla. "Värmeåtervinning ur ventilationsluft i äldre flerbostadshus : En jämförande studie av centralt FTX- och FX system." Thesis, KTH, Byggteknik och design, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-127004.

Full text
Abstract:
En jämförelsestudie har genomförts mellan två värmesystem. Analysen har genomförts med ett flerbostadshus som referensfasighet. Fastigheten är lokaliserad i Södertälje kommun. Analysen går ut på att bestämma vilket värmesystem som är fördelaktigt vid renovering av äldre flerbostadshus med avseende på energi och kostnad. De systemen som har behandlats är ett centralt värmesystem med motströmsvärmeväxlare och ett centralt värmesystem med frånluftsvärmepump. Det centrala värmesystemet (Eq aggregat) är ett centralt från- och tilluftssystem med återvinning (FTX system). Systemet använder en motströmsvärmeväxlare för överföring av värmeenergi mellan från- och tilluften. Det centrala värmesystemet (Energi well) är ett frånluftssystem (FX system) med en ny teknisk lösning. Systemet återvinner värme ur frånluften med hjälp av kondenserande frånluftsvärmpumpar. Värmepumparna finns i en frånluftskammare på vindsvåningen. Den återvunna värmen förs sedan vidare till undercentralen för att värma upp varmvattnet. Analysen har genomförts med hjälp av teoretiska energi- och kostnadsberäkningar, intervjuer och faktainsamlingar.  Energiberäkningarna har bestått av en energibalansberäkning för att få fram den köpta energiförbrukningen. Kostnadsberäkningar har bestått av en livscykelkostnads kalkyl och en kostnads beräkning per producerad värmeenergi. De resulterande värdena för båda värmesystemen har sedan jämförts med varandra. Resultatet visade att värmesystemet Energy well var mest fördelaktig ur både energi och kostnad perspektiv. Den årliga köpta energiförbrukningen var                          lägre än värmesystemet (Eq aggregat) med en motströmsvärmeväxlare. Driftkostnaden var  lägre än Eq aggregat, installations-kostnaderna var  lägre än Eq aggregat och slutlig var livscykelkostnaden  lägre än värme-systemet (Eq aggregat) med motströmsvärmeväxlare. Men underhållskostnaden var  högre än värmesystemet Eq aggregat. Slutsatserna för de teoretiska undersökningarna gav bättre värden för värmesystemet Energy well. Vilket innebär att Energy well är mest fördelaktig utifrån energi- och kostnads perspektiv. Däremot ger värmesystemet med motströmsvärmeväxlare en lägre risk att ett driftfel inträffar i verkligheten.<br>A comparing study between two different heating systems has been accomplished. The analysis has been conducted with an apartments building as a reference project. The building is located in the municipality of Södertälje. The goal of the analysis is to determine which of the heating system is beneficial for older apartment buildings in terms of energy and cost. The systems that have been treated are a central heating system with a counterflow heat exchanger and a central heating system with an exhaust air heat pump. The central heating system (Eq unit) is a central exhaust- and supply air system with heat recovery. The system uses a counterflow heat exchanger to transfer the heat energy between the exhaust- and supply air. The central heating system (Energy well) is the latest technical solution of a central exhaust air system. The system recovers heat from exhaust air by condensing exhaust air heat pumps. The heat pumps are in an exhaust air chamber and it´s placed on the attic floor. The recovered heat energy sends then to the mechanical room to heat up the water system. The analysis has been accomplished by using theoretical energy- and cost calculations, interviews and data collection. The energy calculations are based on an energy balance equation to determine the bought energy consumption. The cost calculation is based on a life cycle cost equation and a cost equation per produced heat energy. The results of both heating systems have been compared with each other. The results showed that the heating system Energy well was most beneficial in both energy and cost perspective. The annual consumption of bought energy was                          lower each year than the heating system (Eq unit) with a counterflow heat exchanger. The operating costs of the system were  lower than Eq unit, the installation costs were  lower than Eq unit and final was the life cycle cost  less than the heating system (Eq unit) with counterflow heat exchanger. But the service cost was  higher than the heating system Eq unit. The conclusion of the theoretical investigations gave better values ​​for the heating system Energy well. This means than Energy well is most beneficial from the energy and cost perspectives. Contrariwise has the heating system with counterflow heat exchanger a lower risk of an operational failure to occur in reality.
APA, Harvard, Vancouver, ISO, and other styles
31

Fjellstedt, Johan. "Energioptimering av tryckluft : Genom värmeåtervinning och driftoptimeringar för industriella tillämpningar på Volvo Trucks i Umeå." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-160431.

Full text
Abstract:
Volvo Trucks in Umeå use large amounts of compressed air and the air compressors at Volvo use large amounts of energy every year. The majority of the energy supplied to the compressors goes to heat losses cooled to the Ume River and groundwater. The purpose of this project was to develop a new heat recovery system where a larger part of the compressor heat is used and various suggestions for optimizations on the compressed air system. Lack of digital control systems on the compressed air system has led to various operating problems and difficulties in diagnosing them while making optimizations difficult. The absence of logged data led to lack of various critical compressor data that instead had to be estimated with different calculation methods. The report resulted in a number of measures that were proposed, such as an investment in a variable speed drive compressor with heat recovery to the district heating system, various operating optimizations and a reworking of the current heat recovery system. The heat recovery systems showed to have great saving potential with a short payback period. The heat recovery systems that were developed in the project was to recycle heat from a new air compressor to the return line on the district heating at a station inside the factory and a heat exchange on three current compressors towards a nearby district heating line. It was thus possible to show significant reductions in the amount of purchased district heating and energy costs without affecting other processes. An outdated compressed air system showed higher future costs due to increased service costs and a future need for renovations on compressors. This means that Volvo probably would have reduced costs by investing in a new air compressor.
APA, Harvard, Vancouver, ISO, and other styles
32

Hammarström, Anton. "Utvärdering av potential för värmeåtervinning från laborationsutrustning : Möjligheten att använda en kylvattenbassäng som termiskt säsongslager." Thesis, Mittuniversitetet, Avdelningen för kemiteknik, 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-34309.

Full text
Abstract:
HETA utbildningar i Härnösand har ett ångkraftverk för undervisningssyfte som kyls ner med vatten från en underjordisk bassäng på cirka 329 m³. Syftet med detta examensarbete har varit att undersöka hur bassängen med spillvärmen från kraftverket kan användas som ett säsongslager i kombination med en befintlig 7,8 kW värmepump för att värma upp maskinhallen i deras laboratoriebyggnad. Ett kalkylark skapades i Microsoft Excel för att kunna genomföra beräkningarna. Då mätdata saknades skapades ett simulerat scenario baserat på temperaturstatistik och körschema för kraftverket från år 2017. Transmissionsförluster beräknades för bassängen och maskinhallen. För bassängen användes mestadels observationsdata och kännedom hos personalen, medan maskinhallens isolering i huvudsak fick uppskattas efter byggår. Resultatet blev att värmepumpen med aktuellt körschema kunde täcka cirka 45 % av maskinhallens årliga uppvärmningsbehov. Av de 276 GJ som tillfördes genom kylning av ångkraftverket under ett år beräknades endast 2,7 % kunna utnyttjas till uppvärmning av maskinhallen, på grund av för lite isolering i bassängen. De största begränsningarna för högre täckning och större nyttjande av spillvärmen bedömdes vara placeringen i tid av kraftverkets körningar, och värmepumpens effekt. Om körningarna skulle förläggas i huvudsak till november–april och värmepumpen ersättas med en på 10 kW, skulle 74 % av värmebehovet kunna täckas och över 18 % av spillvärmen utnyttjas. Andra saker som förbättrad isolering i bassängen och större vattenvolym bedömdes också kunna förbättra bassängens kapacitet som energilager.<br>HETA Education in Härnösand has a steam power plant for educational purposes which is cooled with water from a 329 m³ underground basin. The purpose of this thesis has been to examine how the basin with the waste heat can be used as seasonal thermal energy storage with an existing 7.8 kW heat pump in order to heat the machine room of their lab building. A spreadsheet was created in Microsoft Excel in order to carry out the calculations. As no measurement data was available, a simulated scenario was created based on temperature statistics and the operating schedule for the power plant from the year 2017. Transmission losses were calculated for the basin and the machine room. For the basin, mostly observational data and knowledge among the staff were used, while the insulation for the machine room mainly had to be estimated based on the construction year. The result was that the heat pump, with the current operating schedule, could cover around 45% of the yearly heating demand of the machine room. Of the 276 GJ that were added through cooling of the power plant during a year, according to calculations, only 2,7% could be used for heating the machine hall, due to lacking insulation in the basin. The greatest limitations for achieving a higher heating coverage and a greater usage of the waste heat were assessed to be the placement in time of the power plant runs, and the effect of the heat pump. If the runs would be placed mainly in November–April, and the heat pump replaced with a 10 kW one, around 74% of the heating demand could be covered and 18 % of the waste heat used. Other things, such as increased insulation in the basin and larger water volume were also assessed to be able to increase the capacity of the basin as heat storage.
APA, Harvard, Vancouver, ISO, and other styles
33

Brorsson, Martin, and Erik Danielsson. "Vätskekopplade värme- och kylåtervinningssystem : Utveckling av ett verktyg för energiberäkningar." Thesis, KTH, Installationsteknik, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-126026.

Full text
Abstract:
According to a decision of the European Commission, measures are to be taken to reduce the use of energy in the EU. The goal is to reduce it by 20 % compared to the current use. This shall be done to the year 2020 (European Commission, 2011). One industry that use large amounts of energy is the construction of buildings which account for almost a third of the energy use (Brogren, 2012). The major part of the energy that is used in the construction industry is not used when the buildings are built, but rather during the rest of their subsequent lifetime. There is a great potential to save energy by reducing the energy that is used to maintain a satisfactory indoor climate. Recovery of excess heat and excess cold is a solution that the European Commission think has the biggest potential to reduce the total energy consumption. The most common system used for energy recovery is air to air heat exchangers connected with the supply air and the exhaust air. For different reasons it is not possible to use this kind of system in several buildings. If that is the case there is a possibility to use a liquid coupled recovery system instead. If an additional source of excess heat or excess cooling exist within the building, or nearby, it is also possible to connect this to the system which would increase the ability to save energy even more. The purpose of this thesis has been to develop a tool for energy calculations in liquid-coupled recovery systems. This tool has been developed in the program IDA ICE (used for energy calculations) and has made it possible to perform dynamic simulations in this kind of system over the timeframe of a whole year and with a very short calculation time. The tool is flexible in terms of its components and system design so it can be used for several different types of projects. Everything from simple systems with fixed brine flow with only one supply air and exhaust air unit to systems with several units, various types of control possibilities and an addition of excess heat from, for example, a room containing computer servers. The tool that has been developed has been verified and used to calculate the potential to save energy in a system that is installed at the Ångström laboratory in Uppsala. The tool has shown that with the kind of control and the conditions that currently exist at the laboratory the energy consumption could be reduced by 444 MWh which in this case almost is 50 % of the current energy consumption. Besides the recovery system in Ångström two more systems have been investigated, a server room for The Royal Institute of Technology and the server halls that Facebook is building near Luleå town. The investigation shows that there exist very large amounts of heat that is possible to recover in buildings that include server rooms and that the installed recovery systems, if there are any, in many cases could be improved. Besides constructing recovery systems that recover heat or cold in buildings it is also possible to build this kind of system that recover heat or cold between buildings in the same area. The tool can also be used to investigate how such a system should work in order to minimize the use of energy as much as possible. A solution where heat and cold is recovered between multiple buildings is a solution that probably will be very interesting in the future, which means that this tool could come in handy.
APA, Harvard, Vancouver, ISO, and other styles
34

Lipczynski, Marcus, and Rasmus Becke. "Analys av fjärrvärme med värmeåtervinning via ventilationssystem : Effekterna i form av primärenergi och livscykelutsläpp av koldioxidekvivalenter." Thesis, Linnéuniversitetet, Institutionen för byggd miljö och energiteknik (BET), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-96420.

Full text
Abstract:
För att uppnå Sveriges energi- och klimatmål för energieffektivisering och koldioxidutsläpp måste nya tekniker och innovationer undersökas för att bidra till att göra energianvändningen mer effektiv i bostadssektorn. Ett alternativ för att uppnå målen är att använda ett integrerat värmesystem. De integrerade värmesystemen som undersöks i den här rapporten innefattar värmeåtervinning via ventilation som komplement till fjärrvärme, vilket jämförs med uppvärmning av bara fjärrvärme.   De valda integrerade värmesystemen från HögforsGST kommer undersökas ur ett livscykelutsläpps- och primärenergiperspektiv. Analysen ska utreda om systemen bidrar till att sänka energianvändningen och hur stora livscykelutsläppen av koldioxidekvivalenter är för värmesystemen i två olika fastigheter.   Slutsatsen för rapporten var att de valda integrerade värmesystemen var mer energieffektiva, då de använde mindre primärenergi, oavsett fall för elproduktion. De använde även 36 procent och 32,8 procent mindre producerad energi, för Lärlingen respektive Rundeln. Fjärrvärmesystemet medförde istället lägre totala livscykelutsläpp av koldioxidekvivalenter än det integrerade värmesystemen, för de flesta fallen av elproduktion. För att få ett mer tillförlitligt resultat bör de integrerade värmesystemen granskas under en längre tidsperiod för att vidare analysera använd primärenergi och livscykelutsläpp.
APA, Harvard, Vancouver, ISO, and other styles
35

Eriksson, Simon. "Utredning av potentialen att återvinna mer värmeenergi på boardmaskin 2." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-184373.

Full text
Abstract:
Denna rapport undersöker om det är möjligt att återvinna mer energi och skapa ett större energiöverskott ur värmeåtervinningstornen (AHR-tornen) kopplade till Boardmaskin 2 (BM2) och bestrykaren (CM1) i Metsä Board Husum. Potentiell energieffektivisering och styrning av systemet undersöks även. Anledningen till denna utredning är att Husums kartongbruk utreder möjligheterna till att bygga ut BM1 och öka kartongproduktionen vilket skulle medföra en ökad ångförbrukning och därför ett minskat energiöverskott och mindre elproduktion från turbinerna. Rapporten inleds med allmän information om energisektorn i Sverige och massa/kartongbruk. Innan AHR-tornens uppbyggnad beskrivs så förklaras värmeväxlares funktion. Både hur värmeväxlare fungerar generellt och hur de som används i tornen fungerar. I de tre AHR-tornen cirkulerar tre stycken rörslingor som används för att värma processvarmvatten och lokalerna i fabriken. Fokuset under projektet har främst legat på BM2 AHR1 då det är tornet som överför mest energi från torkluften och involverar alla tre slingor. Om vattnet i en slinga inte når upp till den önskade temperaturen efter det passerat tornen så värms vattnet upp med hjälp av en ångvärmeväxlare. Slingan som är placerad längst ner i BM2 AHR1 kallas för slinga 2. Den håller höga temperaturer året om och ångvärmeväxlaren i kretsen behövs inte användas. Slinga 1 som är placerad ovan värmer processvarmvattnet och måste använda sig av ångvärmeväxlaren året om. Den tredje slingan tar i princip den energi som finns över i tornet efter luften passerat de andra slingorna och håller relativt låga temperaturer, beroende på om CM1 går eller inte. För att uppnå målsättningen gjordes först effektberäkningar över tornen från olika vinterdagar. Resultat visar att tornen överför nästan dubbelt så mycket effekt från torkluften då utetemperaturen är  -15°C jämfört med då utetemperaturen är 10°C . Flödesreglering gjordes sedan på slingorna för att försöka öka utloppstemperaturer och minska elförbrukning från pumparna i slingorna. Utloppstemperaturen i slinga 1 steg med 4°C men ångförbrukningen ökade i viss omfattning, och elbesparingen över pumparna blev 44630 kr/år om flödet skulle reglerats ner under hela året. Slinga 3 har styrts mot ett börvärde på 50°C med hjälp av ångvärmeväxlare vilket ansågs vara onödigt högt. Den ånga som sparas vid varje grads sänkning av börvärde och vad det motsvarar i kostnader beräknades fram till ca 1,12 ton ånga/h eller 1,06 Mkr/år. Slutligen gjordes en beräkning på den potentiella besparingen vid omplacering av slinga 1 och 2. Slinga 1 blir då placerad längst ner i tornet och tar upp mer värme från torkluften. Denna ombyggnad skulle kunna spara 1,79 ton ånga/h eller 1,69 Mkr/år vid bästa fall.<br>This report examines whether it is possible to recover more energy and create a larger energy surplus from the heat recovery towers (AHR towers) connected to Board machine 2 (BM2) and the coater (CM1) in Metsä Board Husum. Potential energy efficiency and control of the system are also investigated. The reason for this investigation is because Husum board mill is investigating the possibilities of expanding BM1 and increasing board production, which would lead to increased steam consumption and therefore a reduced energy surplus and less electricity production from the turbines. The report begins with general information about the energy sector in Sweden and pulp/board use. Before describing the structure of the AHR towers, the function of heat exchangers is explained. In the three AHR towers, three water-filled pipe loops are used to heat process hot water and the premises in the factory. The focus during the project has mainly been on BM2 AHR1 as that tower transfers the most energy from the drying air and involves all 3 pipes. If the water in a pipe does not reach the desired temperature after passing the towers, the water is heated by means of a steam heat exchanger. The pipe located at the bottom of BM2 AHR1 is called pipe 2. It maintains high temperatures all year round and does not need any heating from the steam heat exchanger. Pipe 1, which is located above, heats the process hot water and requires heat addition all year round. The third pipe basically gets the energy left over in the tower after the air has passed the other pipes and maintains relatively low temperatures, depending on whether the CM1 is running or not. To achieve the goal, energy calculations were first made over the towers from different winter days. Results show that the towers transfer almost twice as much energy from the drying air when the outdoor temperature is -15°C compared to when the outdoor temperature is 10°C. Flow control was then done on the pipes to try to increase outlet temperatures and reduce electricity consumption from the connected pumps. The outlet temperature in pipe 1 rose by 4°C, but the steam consumption increased to some extent, and the electricity savings over the pumps were 44630 SEK/year if the flow were to be regulated down throughout the year. Pipe 3 has been controlled to a setpoint of 50°C by means of a steam heat exchanger, which was considered to be unnecessarily high. The steam saved by each degree reduction of setpoint and what it corresponds to in money was calculated up to about 1,12 tonnes of steam/h or 1,06 million SEK/year. Finally, a calculation was made of the potential savings when relocating pipe 1 and 2. Pipe 1 is then placed at the bottom of the tower and absorbs more heat from the drying air. This conversion could save 1,79 tonnes of steam/h or 1,69 million SEK/year at best.
APA, Harvard, Vancouver, ISO, and other styles
36

Persson, Nils. "Utvärdering av värmepumpanläggning på Ödlan 2 : Utredning och felsökning av värmepump för värmeåtervinning med fjärrvärme som spets." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-82050.

Full text
Abstract:
Detta examensarbete har utförts vid Riksbyggen i Umeå och är det avslutande arbetet som uppfyller kraven för en magisterexamen i energiteknik vid Umeå Universitet.   Riksbyggen övertog 2010 ägandet av flera fastigheter på korpralsvägen i Umeå. En upprustning av fastigheterna hade vid övertagandet påbörjats av den tidigare ägaren under 2009. Förutom att rusta upp och bygga till fler lägenheter i de befintliga huskropparna installerades ventilationsåtervinning med värmepump i några av husen. Sedan idrifttagning av den nya ventilationsåtervinningen i husen har värmepumparna levererat dåligt med värme, vilket medfört en högre fjärrvärmeanvändning och driftkostnad för husen än vad som ursprungligen var beräknat. Enligt rådande prismodell för fjärrvärme från Umeå Energi, ska en fjärrvärmekund som installerat värmepump beläggas med en korrektionsfaktor som kraftigt ökar den fasta kostnaden i fjärrvärmepriset. Detta trotts att värmepumpen sänker toppeffektbehovet vilken även är dyr att producera för Umeå Energi. Riksbyggen vill främst veta vad som är fel i de nuvarande värmepumpanläggningarna och om Umeå Energi verkligen förlorar på att toppeffektbehovet sänks för fastigheterna. Genom samtal med underentreprenörer, beräkningar med befintliga data samt utförda mätningar av ventilationsflöde och temperatur har energiprofiler beräknats för värmepumparna och husen.   Det visade sig att den tänkta styrningen av värmepumparnas produktion medför återkopplingsproblem orsakade av fjärrvärmen. Det går att styra fjärrvärmetillsatts överordnat från pumparna vilket eliminerar återkopplingsproblemet men denna lösning har av okänd anledning inte valts. Vid beräkningar av husens energiprestanda visar det sig även att både Umeå Energi och de boende i husen i dagsläget förlorar upp emot 11-13 % av de möjliga intäkterna/ driftkostnaderna på det nuvarande driftfallet. Optimeringsberäkningar visar att förlusten kan vändas till en nästan lika stor vinst för Umeå Energi och göra fjärrvärme som spets betydligt billigare för de boende. Detta förutsätter att värmepumparna stängs av sommartid och att de levererar en jämn grundlast året om. Vinst/förlustmarginalerna för fjärrvärmens vara eller icke vara är dock små och ligger innanför felmarginalen i beräkningarna.<br>This thesis has been written for Riksbyggen in Umeå and is the final examination that completes the requirements necessary to obtain a master’s degree in energy technology of length 1 year at the University of Umeå. Riksbyggen took in 2010 over the ownership of several residential buildings on korpralsvägen in Umeå. The former owner prior to Riksbyggens overtaking initiated a major restoration of the buildings during 2009. In addition to renovating the buildings more apartments were built within the existing building shells. Exhaust air heat recovery in the exiting ventilation with heat pumps, was also installed in some of the houses. Since commissioning the heat pumps haven’t delivered as expected. This has led to higher district heat usage and operating costs than originally calculated. According to Umeå Energis current price model for district heat, customers who install a heat pump get charged with a correction factor that greatly increases the fixed cost of district heat. This is done despite the heat pumps reduce peak power which is the most expensive power to produces for Umeå Energi. Riksbyggen mainly wants to know what’s wrong with the heat pumps and if Umeå Energi really loses when peak power is reduced. Through conversations with the contractors, calculations with existing data and own measurements of air flow and temperature, the energy profiles have been calculated for the buildings and heat pumps. It turned out that the control system for the heat pumps involved a feedback error caused by the addition of district heat. The addition of district heat during peak power tip can be controlled from the pumps own internal control system which eliminates the current feedback problem but this solution has for unknown reasons not been chosen. When calculating the buildings energy performance, it also appears that both Umeå Energi and the residents of the buildings loses up to 11-13% of the possible revenues/operating costs  due to the current operating mode. Optimization calculations show that the loss can be turned into an almost equally large gain for Umeå Energi and make district heat cheaper for the residents to use as peak power tip. This assumes that the heat pumps are turned off during the summer and that heat is delivered steady during the rest of the year.  The gain/loss margin for keeping or getting rid of district heat as peak power tip are although small and lies within the error margin of the calculations.
APA, Harvard, Vancouver, ISO, and other styles
37

Selo, Jovan, and Bora Tayfur. "Frånluftsåtervinning i ett äldre flerfamiljehus : Hovgården - Borlänge." Thesis, Högskolan Dalarna, Byggteknik, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:du-13821.

Full text
Abstract:
I detta examensarbete undersöktes möjligheten att installera värmeåtervinningssystem för ett flerfamiljehus i Hovgården som ligger en bit utanför Borlänge. I rapporten redovisas två olika sätt för energibesparingar som är aktuella för att ersätta borttagning av oljepannan som används i huset i dag. En rad svårigheter dök upp under undersökningen för installation av nytt värmesystem. Lämpliga lösningar kunde hittas efter mycket analys. Syftet med rapporten var att undersöka möjligheten och lönsamheten för installation av något av följande system; FVP eller VBX-modul som kan återvinna värme ur frånluften. Undersökningen visade att varken VBX eller FVP kan ersätta oljepannans värmeavgivning på ett tillfredsställande sätt. Med VBX ökas COP från 2,8 till 3,11 vilket leder till 17 MWh/år elbesparing. Däremot FVP kan försörja huset med 59 MWh/år men kan inte täcka effektbehovet för gården under kallaste dagarna. Resultatet blev att de båda undersökta systemen inte har möjlighet att ersätta oljeeldning.<br>In this thesis, we have studied a building located in Hovgården in Borlänge. The report investigates two energy saving installations that can help to reduce the amount of oil used today in the house. The purpose of the report was to examine the possibilities and viability of exhaust heat pump (FVP) and VBX module that can recover heat from the exhaust air. The investigation showed that neither VBX nor FVP can replace the oil-fired boiler in an acceptable way. With VBX the COP of the existing heat pump is increased from 2.8 to 3.11 leading to 17 MWh/year electricity saving. However FVP can recycle 59 MWh/year from the exhaust air but still cannot cover the power demand of the building during the coldest days. The result was that the two investigated systems are not able to replace oil heating.
APA, Harvard, Vancouver, ISO, and other styles
38

Tuvner, Jesper, and Linnea Schindelar. "Energieffektivisering genom installationstekniska lösningar : Tillämpat på ett projekterat modulhus i Alnarp med fokus på energianvändning inom ventilation med värmeåtervinning och solceller." Thesis, Linnéuniversitetet, Institutionen för byggd miljö och energiteknik (BET), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-96234.

Full text
Abstract:
FN:s klimatpanel IPCC har tagit fram rapporter som visar att de närmaste årens agerande är avgörande för hur klimatförändringarna kommer att se ut. Energianvändningen världen över måste minska och en sektor som har en stor energianvändning är: bostads- och servicesektorn, 39 % av Sveriges totala energianvändning. I den här undersökningen granskades ett projekterat modulhus på 1 650,3 m2 beläget i Alnarp i Malmö, där syftet är att komma med energieffektiviserande åtgärder kopplade mot aktuell BBR. Granskningen av det kommer ske i VIP-Energy, genom simulering och optimering av installationstekniken. Kriterierna som undersöktes är från bedömningssystemet Miljöbyggnad 3.0 där målet på den här undersökningen var att nå GULD, vilket är de med högst krav. Eftersom vi spenderar ca 90 % av vår tid inomhus är det viktigt att inomhusklimatet är av god kvalitet, vilket innebär att en stor energiandel går till den delen. En annan viktig faktor är nyttjandet av solceller på byggnaden och användandet av solceller i Sverige ökar ständigt.   Olika ventilationsaggregat simulerades i IV Produkt Designer G305 och informationen som fåtts från det kunde sedan sättas in i VIP-Energy. Utöver utbyte av ventilationsaggregat granskas även de olika klimatskalen, värmesystem samt olika typer och storlekar på solcellsanläggningen. Energianvändningen för byggnaden jämförs sedan mot målet för Miljöbyggnad GULD på 48 kWh/m2 år. För den specifika byggnaden rekommenderas att välja ventilationsaggregatet Envistar Flex 400 med en solcellsanläggning på 225 m2 på byggnadens söderlutande tak. Om inte fjärrvärme skulle varit ett krav från beställaren hade rekommendationen varit att använda en värmepump istället som värmesystem.
APA, Harvard, Vancouver, ISO, and other styles
39

Salovaara, Tom, and Anna Nordgren. "Energikartläggning & optimering av energisystem : En utredning gällande förbättringsåtgärder av centralkökets energisystem vid Västerås sjukhus." Thesis, Mälardalens högskola, Framtidens energi, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-49139.

Full text
Abstract:
Methods for reduced energy consumption is a current subject due to ongoing climate changes and therefore a current matter in the global discussion. Policies and propositions are developed on both a global and national level, in order to decrease the overall consumption. The global target which embraces the reduction in use of energy affects industries and buildings to practice a more energy efficient usage, as well as developing efficient systems for heat recovery. This project investigates the potential in energy efficiency in a food manufacturing facility who serves Västerås central hospital. The buildings use of energy is calculated as an active heat balance, including ventilation, transmission and unintended ventilation losses. The active heat balance is used as a reference where the percentual energy reduction followed by application of the energy efficient suggestions is calculated, hence, suggestions for energy efficient actions are presented. Energy efficient and economical sustainable suggestions are developed along with the obtained information from visits on-site as well as through discussions with the operating manager. The suggestions contain operation improvements, renovation and upgrades of technical devices. The main focus of the study addressed the buildings heat consumption in both cooled and heated areas.  The suggestions were presented in terms of life cycle cost analysis to display whether the improvement is economical sustainable. It is shown that if all of the suggested improvements are implemented, the reduced energy use for heating could be decreased by 24.5 %. The economic analysis shows that all suggested actions are more cost efficient than the current building and hence considered as profitable. Discussion regarding the proposed actions and the locally developed claim for energy efficient actions were reviewed. The discussion illustrates advantages and disadvantages regarding different kind of heat exchangers as well as how additional isolation in walls affects the buildings heat balance. In conclusion, the results of the suggested actions are discussed and however they are appropriate for the investigated facility.
APA, Harvard, Vancouver, ISO, and other styles
40

Samir, Yasin, and Radojevic Stefan. "Värme och kylbehov för en villa förlagd i en klippa." Thesis, Linnéuniversitetet, Institutionen för byggteknik (BY), 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-97143.

Full text
Abstract:
En stor del av energianvändningen i Sverige används av byggbranschen som uppskattas använda 30 procent av den totala energianvändningen. Därför finns det regler idag som ställer krav för att minska denna energianvändning. I denna studie har en undersökning gjorts av om det går att använda marken för att minska en byggnads värme- och kylbehov. Studien går ut på att beräkna värme- och kylbehovet för ett hus placerat i berg och jämföra det med ett motsvarande hus placerat på mark. Ett klimat motsvarande Malmös valdes för att beräkna värme- och kylbehovet och beräkningarna gjordes med hjälp av programvaran VIP-Energy. Värmetrögheten som finns i berget påverkar värme- och kylförluster genom att värmen behöver längre väg att ta sig ut genom berget till markytan och att temperaturförändring är mycket trögare än i luften. Huset under marken med ett berg med värmekonduktiviteten 1,4 W/moC visade 20 procent lägre värme- och kylbehov jämfört med samma hus placerat på mark. För huset under mark med ett berg med värmekonduktiviteten 3,0 W/moC är värme- och kylbehovet 17 procent lägre jämfört med samma hus placerat på mark.
APA, Harvard, Vancouver, ISO, and other styles
41

Vatn, Sandra. "Möjligheter för nyttiggörandet av värme : Från två metallindustrier i Kronobergs län." Thesis, Linnéuniversitetet, Institutionen för byggd miljö och energiteknik (BET), 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:lnu:diva-45080.

Full text
Abstract:
Potentialen för nyttiggörandet av spillvärme hos två metallindustrier utvärderas. Det ena företaget härdar stål med vatten och det andra gjuter aluminiumtackor i vattenbad och sprayar även vatten som bildar fuktig luft. Vattnet, ej det sprayade, kyls sedan i kyltorn för att kunna återanvändas i processerna. Sankey-diagram för båda företagen presenteras för att tydligt presentera energiflödena i processerna. Värmeåtervinningsförslag presenteras med gasolkostnadsbesparings exempel. Investeringskostnader och återbetalningstider har ej utvärderats. Teoridelen och metoden är användbar för den som vill utvärdera potentialen för värmeåtervinning hos industrier som använder vatten i olika typer av kylprocesser. I teorin presenteras elproduktions metoder för låga temperaturer, dock ansågs inget av företagen vara lämpliga för elproduktion. Värmeåtervinningsförslagen som presenteras innefattar golvvärme, luftvärmare, fjärrvärmeintegrering och värmelager.
APA, Harvard, Vancouver, ISO, and other styles
42

Iverlund, Per. "Värmeväxling med torkluft från Valmets pilotmaskin TM1 : Återvinning av spillvärme vid torkning av mjukpapper." Thesis, Karlstads universitet, Institutionen för ingenjörs- och kemivetenskaper, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-32910.

Full text
Abstract:
Idag ställs stora krav på företag att vara miljömedvetna och resurseffektiva i sin verksamhet. Vid mjukpapperstillverkning används stora energimängder och inom industrin har det under många år funnits en strävan att energieffektivisera processer och att tillvarata spillenergi, bland annat genom värmeåtervinning. Valmet Tissue Technology Center i Karlstad har idag en pilotmaskinen utan värmeåtervinningssystem. Den här undersökningen gjordes i syfte att ta reda på hur stor återvinningspotentialen är för värmeväxling i pilotmaskinens torkpartier, bestående av Yankeekåpan och TAD-cylindrarna. Tre maskinkoncept undersöktes: DCT®, NTT™ och TAD. Entalpi och effekt i utgående torkluft bestämdes utifrån dess massflöde, temperatur och fukthalt för respektive koncept och torkparti. För att beräkna återvinningspotential i luftflödena undersöktes effektbehov för avsättningsalternativ bestående av förvärmning av förbränningsluft och make-up air, uppvärmning av radiatorvatten samt ånggenerering med Waste Heat Steam Generator. Effekt- och energimässig återvinningspotential beräknades dels teoretiskt och dels reellt med simuleringsprogram för befintliga produkter. Ekonomisk besparing från minskad energianvändning samt investeringskostnad för respektive avsättningsalternativ och torkparti beräknades. Paybacktid användes som mått på ekonomisk lönsamhet. Utöver ovanstående undersöktes om det finns ett samband mellan aktivitet på pilotmaskinen och effekttopparna för fjärrvärmeanvändning i den aktuella byggnaden. Störst entalpi har utgående torkluftsflöden från Yankeekåpan vid DCT-körning följt av NTT-körning. Den största effektmässiga återvinningspotentialen för luftförvärmning finns i TAD-cylinder 1 men betydande tryckfall uppstår i värmeväxlaren på grund av stora luftflöden. Waste Heat Steam Generator kan inte användas ihop med pilotmaskinen på grund av för låg entalpi och effekt i utgående torkluft. Generellt är den reella återvinningspotentialen vid luftförvärmning mindre än den teoretiskt beräknade. Totalt innebär värmeväxling från Yankeekåpan den största årliga energibesparingen vid luftförvärmning. Reell energibesparing vid luftförvärmning i Yankeekåpan är 55 MWh per år vilket motsvarar 4 300 kg gasol. För uppvärmning av radiatorvatten finns den största effekt- och energimässiga återvinningspotentialen vid värmeväxling i Yankeekåpan under DCT-körning följt av NTT-körning. TAD-körning innebär en mindre återvinningspotential vid värmeväxling både i Yankeekåpan och TAD-cylindrarna. Totalt innebär värmeväxling från Yankeekåpan den största årliga energibesparingen vid uppvärmning av radiatorvatten. Reell energibesparing vid uppvärmning av radiatorvatten med torkluft från Yankeekåpan är 153 MWh fjärrvärme per år. Årlig kostnadsbesparing vid luftförvärmning är 43 000 SEK och vid uppvärmning av radiatorvatten 63 400 SEK. Paybacktid för investering i luftförvärmning är 2,6 år och för uppvärmning av radiatorvatten 4,4 år. Ett samband mellan att pilotmaskinen körs och hög fjärrvärmeförbrukning finns, dock är det rutinförändringar kring lokalventilering under körning som främst kan bidra till att sänka de högsta effekttopparna.<br>There are great demands on industrial companies today to be environmentally responsible and resource-efficient. Within the paper and tissue industry a lot of energy is being used in the processes and since many years there’s been a development towards a more efficient energy use, for example by recovery of waste heat. Valmet Tissue Technology Center in Karlstad, Sweden, has a pilot tissue machine without a waste heat recovery system. This thesis was carried out to investigate the waste heat recovery potential of the pilot machine’s drying sections, being the Yankee hood and TAD cylinders. Three different concepts of the machine were studied: DCT®, NTT™ and TAD. The enthalpy and heat flows of the exhaust air from the drying sections were calculated by the air’s mass flow, temperature and humidity. To calculate the heat recovery potential the heat demand for pre-heating combustion and make-up air, heating radiator water and generating steam by using a Waste Heat Steam Generator was investigated. The heat recovery potential was calculated theoretically but also simulated using programs for real heat exchangers. Economic savings from reduced energy use and investment costs was used to calculate the payback time for each investment alternative. As a separate task the maximum district heating loads in the facility of the pilot machine was cross checked with the pilot machine activity, to clarify any relationship between them. The largest enthalpy was found to be in the exhaust air from the Yankee hood when running the DCT concept followed by the NTT concept. However, the largest heat flow is in the exhaust air from the first TAD cylinder. The air from the first TAD cylinder meant the largest heat recovery potential but caused big pressure drops in the heat exchanger. The Waste Heat Steam Generator cannot be used together with the pilot machine due to too low enthalpy and heat flow in the exhaust air from the drying sections. In general the real heat recovery potential when pre-heating combustion and make-up air is smaller than the theoretical potential. In total, heat exchange using exhaust air from the Yankee hood means the largest energy saving when pre-heating air. The real energy saving when pre-heating air using outgoing air from the Yankee hood is 55 MWh per year, meaning 4 300 kg of propane. The largest potential for heating radiator water occurs when using exhaust air from the Yankee hood when running the DCT concept followed by the NTT concept. The TAD concept means smaller heat recovery potential regardless of air from the Yankee hood or TAD cylinders is being used. In total, heat exchange using outgoing air from the Yankee hood means the largest yearly energy saving when heating radiator water, the real energy saving in district heating being 153 MWh per year. The economic saving when pre-heating air is 43 000 SEK per year and when heating radiator water 63 400 SEK per year. The payback time when investing in pre-heating air is 2,6 years and when heating radiator water 4,4 years. A relationship between running the pilot machine and big loads of district heating use can be seen. However, changing the routines of ventilation in the machine hall during trial days would probably be the easiest way to reduce the maximum loads.
APA, Harvard, Vancouver, ISO, and other styles
43

Andersson, Edwin. "Cooperation for Heat Recovery : A Case Study on Heat Utilization From a Supermarket Refrigeration System." Thesis, KTH, Energiteknik, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-299769.

Full text
Abstract:
The study looks at heat recovery of a refrigeration system in a supermarket where the heat was supplied to apartments in the same building. Such a system requires cooperation between the supermarket owner and the property owner, with both having different motives. By gaining understanding of each other's needs and obligations, cooperation can become easier to achieve, with a result that is more optimal for both actors. Heat recovery for use within the supermarkets has existed for a long time, though supplying the heat to other actors is not as common. Using CO2 as refrigerant is becoming more popular in supermarket refrigeration systems, which allows for achieving higher temperatures in recovered heat, enabling use in radiator systems or for preheating domestic hot water. In lack of other cooling solutions, the supermarket studied in the project had previously used municipal water for cooling of the condenser in the refrigeration system, which is a costly solution that does not utilize the heat. The amount of heat that can be recovered was estimated and compared to the varied amount of heat demand in the supermarket and the rest of the property over a year. Findings show that heat recovery from the refrigeration system create considerable cost savings for both the supermarket owner and the property owner, despite still requiring cooling with municipal water during summer. Financial compensation for delivered heat is difficult to argue for at moment, though it may become relevant if new solutions for cooling of the refrigeration system are proved to be feasible.<br>Se filen
APA, Harvard, Vancouver, ISO, and other styles
44

Svensson, Mikaela. "Funktionsbeskrivning och styrning av industriellt värmesystem : Avgaspanna, Volvo GTO i Skövde." Thesis, Högskolan i Skövde, Institutionen för ingenjörsvetenskap, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:his:diva-17285.

Full text
Abstract:
Med hjälp av systembilder, PLC-kod, studiebesök och intervjuer konstruerades en funktionsbeskrivning för styrning och hantering av ett värmeåtervinningssystem vid namn Avgaspannan, på Volvo GTOs, f.d. Powertrain, anläggning i Skövde. Syftet bakom examensarbetet var att skapa en funktions-beskrivning som skulle vara ett stöd för nuvarande, men även blivande personal. Eftersom det i dags-läget inte finns någon dokumentation kring styrningen av systemet. Tanken bakom arbetet är att med hjälp av redan existerande programkod och systembilder skapa en väldokumenterad och välfylld funktionsbeskrivning. För att komplettera dokumentet till största möjliga mån, genomfördes även studiebesök för att se systemet i verkligheten samt genomfördes även intervjuer för att erhålla information och kommentarer från driftpersonalen. Värmeåtervinningssystemet utvinner värmen från producerade avgaser från smältugnarna i Gjuteriet. Värmen som utvinns värmer i sin tur upp fjärrvärmevatten som sedan pumpas ut på Skövde kommuns Fjärrvärmenät för att under vinterhalvåret hjälpa till och förse Skövde med värme. De steg och moment som utfördes under arbetets gång har resulterat i ett godkänt dokument hos aktörerna och de är nöjda med arbetet. För att kunna nå det färdiga resultatet genomfördes studier kring och i PLC-programmet samt systembilder, det utfördes även studiebesök och intervjuer. Dessa mo-ment var byggstenarna för att kunna få ett godkänt resultat.<br>With the aid of system images, PLC-code, studies at the facility and interviews, a functional description was designed for the control and management of a waste heat boiler named Avgaspannan, at Volvo GTOs, Powertrain, plant in Skövde. The purpose of the thesis was to create a functional description that would support current, but also prospective staff. Since there is currently, no documentation regarding the control of the system. The idea behind the work is to create a well-documented and well-filled function description by using already existing program-code and system images. To supplement the document to the greatest extent possible, studies at the facility and the real system was made. Interviews were also conducted to obtain information and comments from the operating staff.The heat recovery system extracts the heat from produced exhaust gases from the smelters in the foundry. The heat that is extracted, will heat up the district heating water, which is then pumped out on Skövde municipality’s heating network in order to help and provide Skövde with heat during the winter. The steps performed during the course of the work have resulted in an approved document by the actors and they are satisfied with the work. To be able to achieve the final result, studies were conducted on and in the PLC-code and system images, as well as study visits and interviews. These elements were the building blocks for being able to get an approved result.
APA, Harvard, Vancouver, ISO, and other styles
45

Wallin, Jonas, and Gustav Dahlqvist-Sjöberg. "Energioptimering av VVS-system : Energibesparingsåtgärder och arbetsmetoder för att minska inköpt energi." Thesis, KTH, Byggteknik och design, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-259940.

Full text
Abstract:
Akademiska Hus AB är ett statligt ägt fastighetsbolag med uppdrag att äga och förvalta fastigheter för utbildning, forskning och studentbostäder. Ett av deras energimål är att halvera mängden inköpt energi till år 2025 med startår 2000. Syftet med detta examensarbete är att undersöka förbättringsmöjligheter och åtgärder kopplade till VVS-system för att nå energimålet. Arbetet har utförts på förvaltningsområdet Campus Solna som har ett specialavtal med Stockholm Exergi för fjärrvärme och fjärrkyla. Specialavtalet är utformat med fördelaktiga tariffer vid hög nyttjandegrad, ett exempel är kompensation vid användning av fjärrkyla under vinterperioden men det föreligger tilläggsavgifter vid underutnyttjad leverans. Detta sätter begränsningar i vilka typer av besparingsåtgärder som kan utföras med positivt ekonomiskt resultat samt minskad andel inköpt energi. De besparingsåtgärder som har valts för beräkningar är två typer av värmepumpslösningar och ett byte till effektivare värmeåtervinningsbatterier. Beräkningarna har utförts med hänsyn till gällande avtal och därefter jämförts mot ett annat befintligt standardavtal inom Akademiska Hus för att undersöka om förvaltningsområdet Campus Solna skulle gynnas av en annan avtalsform. Nyttjandetiden för fjärrvärme och fjärrkyla är ett förhållande mellan energi och effekt visar resultatet att de åtgärder där den procentuella andelen mellan energi- och effektbesparing är ungefär lika stor finns största ekonomiska lönsamheten. Resultatet efter utförda beräkningar visar att de två typerna av värmepumpslösningar ger stora besparingar i inköpt energi men i förhållande till effektbesparingarna generar detta tilläggsavgifter och en ekonomisk förlust. Vid jämförelse mot standardavtalet utan tilläggsavgifter sparas en stor andel inköpt energi och den potentiella ekonomiska besparingen ökar. Dock, visade det sig vid en totalkostnadsanalys att den årliga kostnaden för värmepumpslösningen med standardavtalet blir lika stor som kostnaden med det befintliga avtalet utan någon åtgärd och detta på grund av att tarifferna för inköpt fjärrvärme och fjärrkyla är högre. Värmeåtervinningsbatterierna har ett bättre förhållande mellan energi- och effektbesparing vilket resulterar i en ekonomisk vinst även vid gällande avtal. Eftersom återvinning av värme minskar andelen förbrukad energi är det även positivt ur en miljö- och hållbarhetssynpunkt. Slutsatsen är att om det befintliga avtalet fortsätter att nyttjas måste åtgärder som skapar ett bra förhållande mellan energi- och effektbesparing hittas. Alternativet är att försöka förhandla fram ett nytt avtal när gällande specialavtal löper ut för att göra åtgärder som värmepumpar lönsamma. Utöver ovannämnda undersökning har arbetsmetoderna för energibesparingar på Akademiska Hus undersökts genom kvalitativa intervjuer där syftet var att belysa hur nuvarande samarbete ser ut mellan de olika yrkesrollerna samt om det finns en tydlig strategi för hur energimålet ska nås. En slutsats efter utförda intervjuer är att det upplevs att det finns för lite tid att genomföra ett energiarbete. Bakomliggande orsak till detta anses vara att det skulle behövas en bättre arbetsmetodik, tydligare struktur för arbetsfördelning samt mer resurser i form av en dedikerad arbetsgrupp som jobbar operativt med energifrågan.<br>Akademiska Hus AB is a government owned real estate company, their primary mission is to own and administrate facilities for education, research and student housing. One of their energy goals is to reduce the amount of acquired energy by half between the year 2000 and 2025. The purpose of this thesis is to find solutions and ways to make improvements regarding HVAC-systems to achieve this energy goal. The work has been carried out at the property area Campus Solna, which have an agreement with special amendments and conditions with Stockholm Exergi concerning district heating and cooling. The agreement is designed with beneficial tariffs at high utilization, one example is that during the winter season Akademiska Hus gets compensated for using the district cooling but it also exists surcharges at underutilization of delivered heating and cooling. This puts limitations in which types of measures that can be performed to reduce the amount of acquired energy and at the same time have a positive economical result. The selected solutions are two different types of heat pumps and a change to more efficient heat recovery exchangers for ventilation. The calculations have been executed with regard to the current special agreement and then compared to another existing agreement within the corporation to examine if Campus Solna would benefit from another agreement. The utilization time for the district heating and cooling consist of a relation between energy and power, results show that saving measures where the ratio between them are about the same size is the most profitable economically. The results after the performed calculations show that the two types of heating pumps generate large savings in acquired energy but in relation to the reduced power usage causes surcharges and an economical loss. When compared to the other agreement without the additional charges the potential economical outcome improves while reducing the acquired energy. However, when performing a total cost analysis, the calculations with the other agreement indicate that the total annual cost for acquired energy with the heating pump solutions will amount to the same as using the existing agreement without performing any energy saving measures. This is due to the difference in tariffs between the agreements. The heat recovery exchangers have a better relation between energy and power savings, which results in an economical profit regardless of the agreements. This measure also decreases the consumed energy, which has a positive impact on the environment and sustainability. In conclusion, if the current agreement is to be used in the future energy saving measures have to meet the requirement of the energy and power ratio. However, finding enough of such measures that helps Campus Solna to achieve their energy goal can be problematic. The alternative is to renegotiate the agreement to make solutions like heat pumps profitable. Through qualitative interviews with a selection of personnel, work methods connected to energy saving has been discussed to see if there are possibilities for improvements regarding collaboration between the different departments to achieve the energy goal. One conclusion after the interviews is that the personnel are experiencing that there is not enough time to focus on energy savings and projects in their daily work. Hence, there is a need for better working methods, a clearer structure for how the work is to be distributed and more resources in the form of a dedicated working group that works operationally with the energy issue.
APA, Harvard, Vancouver, ISO, and other styles
46

Uludag, Suat, and Helmut Diliwi. "Potential measures and improvements in energy consumptions regarding ventilations systems with heat recovery." Thesis, KTH, Byggteknik och design, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-254162.

Full text
Abstract:
The ventilation system is in itself a huge necessity in our everyday life as it provides sufficient amount of fresh air to our indoor climate, while it simultaneously circulates the residing air pollutants out of the building. Although, for this to be made possible, large amounts of energy is required to be consumed, which in turn leads to an increased energy cost. The knowledge to minimize the use of energy occurs in many different scopes of practices throughout our society. Many people however, avoid such measures due to the high initial costs which are presented, but also because they haven't enough awareness of how they should rectify the problem. The Study is mainly based on researching previously performed measures of system upgrades in the ventilation industry regarding ventilation systems with heat recovery, while understanding the different elements that influences the choice to either upgrade or renovate the already existing system. The implementation of thesis happened through information gathering, a literature study and a qualitative research, which in this case were interviews. The literature study consisted of scientific reports, evaluations and a couple of digital sources which were relevant to the subject we were focusing on. The interviews on the other hand were conducted with experienced officials and employees in the ventilation industry, with the purpose of having a better understanding behind the reason of a system being upgraded. The final results of the study indicated that the most common reason why a costumer/property owner sought an upgrade or renovation of the ventilation system was mainly because of contamination in the heat exchanger, which in return increased the energy consumption while at the same time impaired the indoor climate.<br>Ventilationssystemet är en nödvändighet i vår vardag, då det ska tillföra god inomhusluft samtidigt som den cirkulerar bort luftföroreningarna som finns inuti byggnaden. Men för att detta ska möjliggöras förbrukas stora mängder energi, som i sin tur leder till en ökad energikostnad. Kunskapen för att minimera energianvändningen förekommer i många varierande verksamhetsområden. Däremot är det många som undviker sådana åtgärder på grund av de höga initialkostnaderna men även eftersom de inte har kännedom kring hur dom ska åtgärda problemet. Studien är främst baserad på att ta reda på tidigare utförda åtgärder av systemuppgradering i ventilationsbranschen med inriktning inom ventilationssystem med värmeåtervinning, och genom det begripa vilka faktorer som påverkar valet till att man vill uppgradera eller renovera sitt befintliga system. Genomförandet av arbetet grundades på faktainsamling, litteraturstudie och en kvalitativ forskning i form av intervjuer. Den inhämtade litteraturen bestod av vetenskapliga rapporter, teknikupphandlingar, utvärderingar och digitala källor som var relevanta kring ämnesområdet. Intervjuerna utfördes med erfarna tjänstemän inom branschen, i syfte med att innehava en djupare förståelse kring systemuppgradering av ventilationssystem och anledningen till detta. Slutresultat av undersökningen tydde på att den mest förekommande anledningen till att en kund/fastighetsägare sökte en uppgradering eller renovering av sitt ventilationssystem med värmeåtervinning var på grund av nedsmutsning i värmeväxlaren, vilket försämrade inomhusklimatet och ökade energiförbrukningen.
APA, Harvard, Vancouver, ISO, and other styles
47

Andersson, Josefin. "Utredning av värmesystem i Boliden AB:s anläggning vid Tara-gruvan." Thesis, Umeå universitet, Institutionen för tillämpad fysik och elektronik, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-79326.

Full text
Abstract:
Sommaren 2009 besökte WSP en anläggning i anslutning till Taragruvan i Navan, Irland. Syftet av deras besök var att se över ventilationssystemet som var föråldrat. I och med besöket insåg besiktaren att även deras värmesystem var i behov av en uppdatering och den uppgiften resulterade till detta examensarbete.   Det övergripande syftet med arbetet är att undersöka hur ett nutida värmesystem kan byggas upp och förbättra inomhusklimatet jämfört med ett äldre system. Uppgiften i arbetet består av att ta fram ett förslag på utformningen av ett nytt system som tar hänsyn till effektbehov och dagens klimatkrav.   Utredningen hänvisar en anläggning som används till omklädningsrum för gruvarbetarna samt kontorslokaler. Där är inomhusmiljön bristande, speciellt i omklädningsrummet där temperaturen och den relativa fukthalten är över rekommenderande värden. Omklädningsrummet är därigenom största fokus i undersökningen. Dessutom värms systemet upp med stora mängder olja vilket bidrar med stora utsläpp till miljön. Att kunna mildra anläggningens påverkan bidrar till ökad motivering för en eventuell investering. Utgångspunkten för arbetet ligger i att upprätta ett systems uppbyggnad utifrån anläggningens behov. Därefter läggs stor vikt vid att finna de rätta komponenterna för att optimera det tilltänkta systemet. För att teoretiskt kunna bygga upp ett system till anläggningen arbetas ett förslag fram via ett flödesschema för att skapa en tidig överblick. Efter detta ska systemets komponenter dimensioneras efter anläggningens behov, där uppvärmningen av tappvarmvatten, ventilationssystem och radiatorsystem samt luftavfuktning i omklädningsrummet inkluderas. För att undersöka möjligheten till ett energieffektivare värmesystem kommer arbetet att inkludera en utvärdering av värmeväxlare, värmepump och luftavfuktare samt inkluderingen av de befintliga ventilations- och värmesystemen.   I resultaten redovisas ett effektiviserat teoretiskt system som minskar energiförbrukningen och förbättrar inomhusklimatet i anläggningen. Genom att utnyttja befintlig värmeenergi kan arbetet redovisa ekonomiska fördelarna som uppkommer genom val av en effektiv värmepump inom systemet.<br>In the summer of 2009, WSP visited a facility adjacent to the Tara-mine at Navan, Ireland. The purpose of their visit was to control the ventilation system which was outdated. During the visit the inspector detected that their heating system also was in need of updating and that task led to this bachelor thesis.   The overall aim of this work is to investigate how a modern heating system can be assembled to improve the indoor climate compared to an older system, where the primary target is to develop a proposal for the formation of a new system that meet the power requirements and today's climate demands.   The study refers to a facility used as a changing room for the miners and as an office premise. The analysis focuses on the changing rooms as the indoor environment is especially inadequate with temperature and relative air humidity above recommendatory values for good indoor climate. In addition, the system is heated with large amounts of oil which contribute with large contaminations to the environment. Being able to moderate the impact the facility contribute to the surroundings is an additional motive for any investment.   The analysis began with an examination of the system demands from the facility’s needs, followed by a search of potential components which could optimize a contemplated system. In order to be able to build this system theoretically correct the thesis established a flow chart. On the basis of the flow chart, the system components is conform adjusted to the facility’s needs, which includes the heating of domestic hot water, ventilation- and heating systems, as well an air dehumidification unit in the locker room. To examine the possibilities of improving the energy efficiency of this heating system, the project will evaluate heat exchangers, a heat pump and a dehumidifier, and a coupling to the existing ventilation and heating systems.   The results are presented as a theoretical system that reduces the facility’s energy consumption and improves indoor climate. By utilizing the accessible thermal energy, the project also presents the economic advantages from choosing an efficient heat pump within the system.
APA, Harvard, Vancouver, ISO, and other styles
48

Pomerancevs, Juris. "Geothermal function integration in ice rinks with CO2 refrigeration system." Thesis, KTH, Tillämpad termodynamik och kylteknik, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-273166.

Full text
Abstract:
Ice rinks are energy intense industrial applications. A typical single sheet ice rink in Sweden uses about 1000 MWh/season. A state-of-the art ice rink systems can use less than 500 MWh/season, indicating the potential for improvements. According to several investigations CO2 refrigeration system with heat recovery has proven to be energy-efficient and cost-effective solution in ice rinks.To further improve the efficiency, geothermal function may be added feature. The objective of this study is to evaluate the geothermal function from techno-economic perspective for a typical ice rink in Sweden. Modelling of several scenarios has been performed. Obtained results suggest that CO2 refrigeration system with 2-stage heat recovery, if upgraded with geothermal function, can save between 1.7 to 6.8% of energy annually. In the best case, this study suggests the geothermal function would pay back in 16.4 years.<br>Ishallar är energikrävande industriella applikationer. En typisk ishall i Sverige använder cirka 1000 MWh / säsong. Ett toppmodernt ishallsystem kan använda mindre än 500 MWh / säsong, vilket indikerar stora förbättringsmöjligheter. Enligt flera undersökningar har CO2-kylsystem med värmeåtervinning visat sig vara energieffektivt och kostnadseffektivt i ishallar.För att ytterligare förbättra effektiviteten kan geotermisk funktion läggas till. Syftet med denna studie är att utvärdera den geotermiska funktionen ur ett tekno-ekonomiskt perspektiv för en typisk ishall i Sverige. En modellering av flera scenarier har utförts. Resultaten antyder att CO2-kylsystem med 2-steg värmeåtervinning, om det uppgraderas med geotermisk funktion, kan spara mellan 1,7 och 6,8% energi årligen. I bästa fall antyder denna studie att den geotermiska funktionen skulle betala tillbaka om 16,4 år.
APA, Harvard, Vancouver, ISO, and other styles
49

Åsander, Henrik. "Tillvaratagande av värmeenergi ur gråvatten med värmepump i flerbostadshus." Thesis, Högskolan i Gävle, Energisystem, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-25099.

Full text
Abstract:
Stora mängder energi lämnar bostäder med avloppsvattnet utan något bemödande att återföra det uppvärmda vattnets värmeenergi tillbaka till byggnaden. Med ökade klimatskalsförbättringar av traditionellt slag för att möta de nära-nollenergikrav på nybyggnationer för bostadshus som träder i kraft i slutet av 2020 kan energiförlusterna i byggnader till allt större del allokeras till det avloppsvatten som lämnar byggnaden. Målet med detta arbete är att undersöka huruvida betydande energibesparingar inom området kan erhållas, samt att bedöma de ekonomiska möjligheterna och utsikterna för att tillvarata värmeenergi med hjälp av värmepump ur gråvatten från  flerbostadshus uppkopplade mot fjärrvärmenät. Och i och med det visa vilka faktorer som visar sig utöva påverkan på de driftmässiga besparingsmöjligheterna samt uppvisa hur pass känsligt resultatet är i förhållande till ett urval av dessa faktorer. Arbetet utgörs av och har genomförts i två delar: en litteraturstudie och en beräkningsstudie. Avloppsvatten kan delas in i spillvatten, dagvatten och dräneringsvatten. Spillvatten är avfallsbidraget från hushåll och andra fastigheter till avloppet. Hushållens spillvatten kan i sin tur indelas i gråvatten och svartvatten. Gråvatten är det vatten som kommer från bad, disk och tvätt, vilket av det skälet även kallas BDT-vatten. Svartvatten är det vatten som spolas ut från toaletter, och kallas därför även klosettvatten. Vid separerade flöden infinner sig möjligheten att tillvarata värmeenergi direkt från gråvatten, som också är den varmare, volymmässigt största och mer lätthanterliga fraktionen, både ur vattenrenings- och värmeåtervinningssynpunkt. Studier på källsorterande system visar på flera fördelar i stort med att hålla hushållens avloppsflöde separerade, såsom bland annat utökad resurseffektivitet av kväve och fosfor vid reningsverken. Nedsmutsning av värmeväxlarytor, i synnerhet av biofilm, utgör en utmaning då avloppsvatten ska användas som värmekälla och är något som måste beaktas även vid tillvaratagande av värme ur gråvatten. Resultatet från beräkningsstudien av ett enskilt fall med tappvarmvattenförvärmning, givet en rad antaganden, gav en driftmässig kostnadsbesparing på cirka 31 000 kr per år och ett nuvärde på dessa årliga besparingar sett över 20 år på cirka 355 000 kr. Energibesparingen uppgick till cirka 63 000 kWh per år vilket innebär en minskning av totala behovet av köpt energi för tappvarmvattenproduktion med cirka 67 % vid uppvärmning av tappvarmvatten till 55 °C. Känslighetsanalysen visar att avgörande parametrar i beräkningsstudien såsom el- och fjärrvärmepris, värmepumpens livslängd och kalkylräntan medför relativt stora förändringar av resultatet om de tillåts att variera. Det är uppenbart att det finns stora mängder energi att återvinna, det är också uppenbart att svårigheter gör att gråvatten som värmekälla inte kan behandlas lättvindigt då bland annat den långsiktiga utvecklingen av vattenanvändningen och hög föroreningsgrad är faktorer som måste beaktas i tillägg till de faktorer som tas upp i känslighetsanalysen. Dubbla system med fjärrvärme och värmepump innebär en högre investering men är samtidigt något som kan ses som ett verktyg för att utnyttja de ökande energiprisvariationer som en allt större andel förnybar icke-reglerbar elproduktion sannolikt innebär genom att helt enkelt kunna variera uppvärmningssätt efter varierande energipriser och finna optimal andelsfördelning. För en fastighetsägare blir det i takt med en sådan utveckling alltmer gynnsamt att kunna välja det som för tiden är det billigaste alternativet.<br>Large amounts of energy leave homes with wastewater without any effort to return the heated water's thermal energy back to the building. With increased thermal envelope improvements of a traditional nature to meet the nearly zero-energy requirements for residential buildings that will come into effect by the end of 2020, energy losses in buildings can increasingly be allocated to the wastewater leaving the building. The aim of this work is to investigate whether significant energy savings in the mentioned area can be obtained, as well as to assess the economic opportunities and prospects for utilizing heat energy from grey water from multi-residential buildings connected to district heating networks with the help of a heat pump. And by that show which factors are shown to influence the operational savings and how sensitive the results are in relation to a selection of these factors. The work consists of and has been carried out in two parts: a literature study and a calculation study. Household wastewater can be divided into grey and black water. Grey water is the water that comes from bath, dishes and laundry and black water is the water that is flushed out of the toilets. Separated flows reveal the possibility of utilizing thermal energy directly from grey water, which is also the warmer, volume largest and more manageable fraction, both from a water purification and heat recovery standpoint. Studies on source separated systems show a wide range of benefits, largely by keeping household wastewater separated, such as increased resource efficiency of nitrogen and phosphorus at the wastewater treatment plants. The contamination of heat exchanger surfaces, especially biofilm, poses a challenge when wastewater is used as a heat source and is something that has to be taken into account even when using grey water as a heat source. The result of the calculations of an individual case with preheating of domestic hot water, given a series of assumptions, resulted in operational cost savings of approximately SEK 31,000 per year and a present value of these annual savings over 20 years of approximately SEK 355,000. Energy savings amounted to approximately 63,000 kWh per year, which means a reduction of the total need for purchased energy for domestic hot water production by 67 % with an assumption of a final domestic hot water temperature of 55 °C. The sensitivity analysis shows that crucial parameters in the calculation study such as electrical and district heating price, heat pump life and discount rate entail relatively large changes in profit if allowed to vary. It is obvious that there are large amounts of energy to potentially recycle. It is also obvious that difficulties cause grey water as a source of heat not be treated easily because, among other things, the long-term development of household water use and high pollution rates are factors that must be considered in addition to the factors brought up in the sensitivity analysis. District heating and heat pump combined imply a higher investment than a single heating system, but at the same time is something that can be seen as a tool for utilizing the assumed increasing energy price variations that an increasing proportion of intermittent renewable power generation implies simply by varying heating configuration with changes in energy prices and finding the optimal share. For a property owner, it would at this point be favorable to be able to choose what the cheapest option is currently.
APA, Harvard, Vancouver, ISO, and other styles
50

Meurling, Axel. "Återvinning av värme från datahall : En ekonomisk jämförelse mellan kylmaskiner och frikyla." Thesis, Mittuniversitetet, Avdelningen för kemiteknik, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-31748.

Full text
Abstract:
I samband med att elkonsumtionen ökar och att allt mer elkrävande utrustning installeras är det intressant att studera vilken metod som bäst lämpar sig för att kyla bort oönskad värme och ifall den värmen kan nyttjas där den är önskad. Målet med denna rapport är att ekonomiskt jämföra två olika lösningar för att kyla två serverhallar som står intill varandra. Ena lösningen är att ersätta kylmaskinerna med värmepumpar med kompletterande borrhål, där det är tänkt att köldmediumet passerar värmepumparna om det finns ett värmebehov. Den andra lösningen är att byta ut befintliga kylmaskiner mot modernare utrustning. Syftet med rapportens resultat är att det ska ligga som grund för ett investeringsbeslut av fastighetsägaren. Aktörerna i serverhallarna utvecklar en sammanlagd effekt om 104kW. Serverhallarnas sammanlagda area på ca 100m2 utgör bara en liten del av den 9877m2 stora fastigheten som är de lokaliserade i, övriga fastigheten fungerar som gymnasieskola. Arbetet har genomförts med hjälp av platsbesök, litteraturstudie, kartläggning av energiförbrukning, framtagning av varaktighetsdiagram och energibehovsberäkningar. Fastigheten har ett maxeffektbehov på 350kW och förbrukar 956000kWh, serverhallen kyls idag med tre kylmaskiner av äldre modell. Värmen som utvecklas i serverhallen används som primärvärme för att värma skolan men fastighetsägaren anser att det inte är så effektivt som det skulle kunna vara, samt att systemet klarar inte av att leverera en tillräckligt varm framledningstemperatur. En lösning med värmepumpar som skulle stå för 75% av effektbehovet tillför då 262,5kW och 717000kWh som innebär en energitäckningsgrad på 94% vilket medför att fjärrvärmeeffekten minskar från 220kW till 87,5kW. En kylmaskinslösning med tänkt kylmaskin klarar av att täcka 67% av effektbehovet och 86% av energibehovet. Fjärrvärmen skulle med kylmaskinslösningen minska från 220kW till 130kW. Investeringskostnaden för värmepumpslösningen med frikyla beräknas till 2090000kr och för kylmaskinen 750000kr. Nettobesparingen för 10 år blir för värmepumpar med frikyla 2930000kr medan kylmaskinerna är dyrare i drift än befintlig kylmetod. Nuvärdet efter 10 år blir för värmepumparna 1220000kr<br>As electricity consumption increases and more demanding equipment is installed, it is interesting to study which method is best suited for cooling off unwanted heat and if that heat can be used where it is desired. The aim of this report is to compare two solutions economically to cool two server halls adjacent to each other. The purpose of the report is that it should be the basis for an investment decision by the property owner. The operators in the server halls develop a total power of 104kW. The total area of the two halls of about 100m2 constitutes to only a small part of the 9877m2 large property in which they are located. The remaining part of the property serves as an upper secondary school. The work has been carried out by means of site visits, literature studies, energy consumption mapping, production of a duration chart and energy demand calculations. The property has a maximum power requirement of 350kW and consumes 956000kWh. The cooling is today supplied by three older cooling units. The heat developed in the server hall is used as primary heat for the school, but the property owner believes it is not as effective as it could be and that the system is unable to deliver sufficiently hot flow temperature. A heat pump solution would account for 75% of the power requirement would supply 262.5kW and 717000kWh, which means an energy coverage of 94%, which reduces the district heating power from 220kW to 87.5kW. A cooling machine solution with the specified cooling unit is capable of covering 67% of the power requirement and 86% of the energy demand. The district heating would decrease with 90kW from present values. The investment cost of the heat pump solution with boreholes is estimated at 2090000kr and for the cooling unit 750000kr. The net savings for 10 years will then be 2930000kr for the heat pumps while the cooling machine solution would be more expensive in operation than the existing solution. The net present value for the heat pumps after 10 years will amount to 1220000kr.
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!

To the bibliography