To see the other types of publications on this topic, follow the link: Vauvat.

Journal articles on the topic 'Vauvat'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Vauvat.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Rikander, Salla. "Vanhempien kokemus vauvan kuolemasta." Psykologia 52, no. 1 (2025): 38–60. https://doi.org/10.62443/psykologia.v52i1.144505.

Full text
Abstract:
Tutkimuksen aihe: Perinataalikuolemalla tarkoitetaan yli 22-viikkoisen tai yli 500 grammaa painavan sikiön syntymistä kuolleena tai vastasyntyneen kuolemaa ensimmäisen viikon aikana. Tämän tutkimuksen tarkoitus on selvittää perinataalikuoleman jälkeen vanhempien kokemusta vauvan kuolemasta ja kuoleman vaikutuksista vanhempien elämään sekä traumaoireiden, masennusoireiden ja ahdistusoireiden ilmenemistä vauvansa menettäneillä vanhemmilla. Aineisto: Vauvansa menettäneet vanhemmat rekrytoitiin 12 kuukauden ajalla vuosina 2012–2013 Pirkanmaan sairaanhoitopiirin Tampereen yliopistollisen keskussair
APA, Harvard, Vancouver, ISO, and other styles
2

Henninger, Laurent. "Vauban." Revue Défense Nationale N° 833, no. 8 (2020): 115–18. http://dx.doi.org/10.3917/rdna.833.0115.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Vaupot, Sonia. "The Relationship between the State and the Church in Vietnam through the History of the Society of Foreign Missions of Paris." Bogoslovni vestnik 79, no. 3 (2019): 825–36. http://dx.doi.org/10.34291/bv2019/03/vaupot.

Full text
Abstract:
Religion and the Catholic Church have played an important role in Vietnamese history. The article examines the development of the Catholic Church in Vietnam, from the 17th Century to the 20th Century, based on reports published by the Society of Foreign Missions of Paris (M.E.P.) who contributed to the evangelization of many Asian countries. In this contribution, we will highlight the work and the development of the M.E.P through their reports. We will also focus on the relationship between the states who played a specific role in the history of the Catholic Church in Vietnam, from the creatio
APA, Harvard, Vancouver, ISO, and other styles
4

GOSHIMA, RIHEE. "AN EXPERIMENTAL STUDY OF THE DOMICAL VAUJLT OF ST. SERGE. : Study of the construction method of the domical rib vault." Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ) 383 (1988): 108–20. http://dx.doi.org/10.3130/aijax.383.0_108.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Taassori, Meysam, Ali Shafiee, and Rajeev Balasubramonian. "VAULT." ACM SIGPLAN Notices 53, no. 2 (2018): 665–78. http://dx.doi.org/10.1145/3296957.3177155.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Taillemite, Étienne. "Un conflit Vauban-Louvois." Histoire, économie et société 15, no. 1 (1996): 113–15. http://dx.doi.org/10.3406/hes.1996.1856.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Quealy-Gainer, Kate. "Insanity by Susan Vaught." Bulletin of the Center for Children's Books 67, no. 5 (2014): 288. http://dx.doi.org/10.1353/bcc.2014.0070.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

González Moreno-Navarro, José Luis. "La bóveda tabicada: entre la conservación y la destrucción." Informes de la Construcción 56, no. 496 (2005): 67–72. http://dx.doi.org/10.3989/ic.2005.v57.i496.495.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Huerta, Santiago. "Mecánica de las bóvedas de fábrica: el enfoque del equilibrio." Informes de la Construcción 56, no. 496 (2005): 73–89. http://dx.doi.org/10.3989/ic.2005.v57.i496.496.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Holzmann, Gerard J. "Code Vault." IEEE Software 35, no. 5 (2018): 85–87. http://dx.doi.org/10.1109/ms.2018.3571225.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Huycke, LaRae. "The Vault." AJN, American Journal of Nursing 107, no. 6 (2007): 88. http://dx.doi.org/10.1097/01.naj.0000271862.22075.db.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Gutmann, Ludwig. "The vault." Neurology 91, no. 2 (2018): 94–96. http://dx.doi.org/10.1212/wnl.0000000000005760.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Weaver, Afaa Michael. "Vault-Mates." Pleiades: Literature in Context 37, no. 2 (2017): 177. http://dx.doi.org/10.1353/plc.2017.0152.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Cerpa, Andrés. "The Vault." Ploughshares 45, no. 1 (2019): 23. http://dx.doi.org/10.1353/plo.2019.0006.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Singh, Sanket. "Evidence Vault." INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT 08, no. 05 (2024): 1–5. http://dx.doi.org/10.55041/ijsrem33349.

Full text
Abstract:
Ensuring the integrity of evidence is paramount within the realm of digital forensics. The preservation of evidence gathered at a crime scene is essential for concluding investigations and delivering justice to those involved. Hence, it is imperative to safeguard this evidence from any form of tampering. The process that upholds the reliability of evidence is known as the "chain of custody." Failure to maintain the chain of custody can render the evidence inadmissible in court, potentially resulting in the dismissal of the case. To address these challenges and promote an eco-friendly approach,
APA, Harvard, Vancouver, ISO, and other styles
16

Tang, Chuhao, Tong Sun, Hongyu Duan, Yilin Liu, and Hong Qi. "Evaluation of the Performance of Two Nomograms and Four Vault Prediction Formulas for Implantable Collamer Lens Size Selection." Journal of Refractive Surgery 39, no. 7 (2023): 456–61. http://dx.doi.org/10.3928/1081597x-20230605-01.

Full text
Abstract:
Purpose: To evaluate the performance of different nomograms and vault prediction formulas in predicting the optimal Implantable Collamer Lens (ICL; STAAR Surgical) size and vault. Methods: This retrospective study included 108 participants (214 eyes) who underwent ICL implantation. The efficacy of the manufacturer's nomogram, Parkhurst nomogram, NK formula, KS formula, Zhu formula, and ZZ formula was assessed by comparing the indicated ICL sizes to the postoperative vault measurements. Additionally, Bland-Altman plots and the Friedman test were used to assess the agreement and absolute error b
APA, Harvard, Vancouver, ISO, and other styles
17

Baldioli, Vittoria, Richard Gunn, Sanders MacDonald, and Aly Mackay. "THE DOUNREAY FAST REACTOR VAULT CHARACTERISATION USING THE MONTE CARLO N-PARTICLE CODE AS A TOOL TO SUPPORT DECOMMISSIONING PLANNING." EPJ Web of Conferences 247 (2021): 04004. http://dx.doi.org/10.1051/epjconf/202124704004.

Full text
Abstract:
A combined empirical and theoretical characterisation approach was taken in order to investigate the activity distribution and inventory in the Dounreay Fast Reactor (DFR) vault, so as to aid with the decommissioning and waste management strategy of the cooling circuits located within the shielded vault. The DFR vault is a no-man access, shielded void, which surrounds the reactor core and the graphite shield. Empirical data was collected through various Non-Destructive Assay methods, utilising all available accesses into the reactor vault. This collection of information was then used to make a
APA, Harvard, Vancouver, ISO, and other styles
18

Zhu, Jun, Xue-Ying Zhu, Fen-Fen Li, Ye Yang, and Yu-Feng Ye. "Clinical prediction of insufficient vaults after implantable collamer lens implantation." International Journal of Ophthalmology 17, no. 7 (2024): 1300–1306. http://dx.doi.org/10.18240/ijo.2024.07.15.

Full text
Abstract:
AIM: To determine the factors related to preoperative ocular characters that are predictive of insufficient vault (<250 μm) after implantable collamer lens (ICL V4c; STAAR Surgical) implantation. METHODS: The participants underwent ICL surgery and were divided into the low (<250 μm) and normal (250-1000 μm) vault groups based on the postoperative vault at 3mo. The preoperative biometric parameters and clinical outcomes were compared between the two groups. The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized es
APA, Harvard, Vancouver, ISO, and other styles
19

Taube, Magdalena, Natalia Lisiak, Ewa Totoń, and Błażej Rubiś. "Human Vault RNAs: Exploring Their Potential Role in Cellular Metabolism." International Journal of Molecular Sciences 25, no. 7 (2024): 4072. http://dx.doi.org/10.3390/ijms25074072.

Full text
Abstract:
Non-coding RNAs have been described as crucial regulators of gene expression and guards of cellular homeostasis. Some recent papers focused on vault RNAs, one of the classes of non-coding RNA, and their role in cell proliferation, tumorigenesis, apoptosis, cancer response to therapy, and autophagy, which makes them potential therapy targets in oncology. In the human genome, four vault RNA paralogues can be distinguished. They are associated with vault complexes, considered the largest ribonucleoprotein complexes. The protein part of these complexes consists of a major vault protein (MVP) and t
APA, Harvard, Vancouver, ISO, and other styles
20

Bednarz, Łukasz, Izabela Drygała, Joanna Dulińska, and Jerzy Jasieńko. "Study of Materials Behavior in a Monumental Vault Strengthened by a Carbon Net in a Mineral Matrix Subjected to Seismic Influence." Applied Sciences 11, no. 3 (2021): 1015. http://dx.doi.org/10.3390/app11031015.

Full text
Abstract:
The application of the elasto-plastic material model known as the Barcelona Model (BM) for numerical assessment of a historical vault subjected to earthquake sequence is presented in this work. As a case study, part of a masonry vault erected in Southern Poland in the 12th century was chosen. For the study purposes, a 3D finite element model (FEM) of the vault was prepared using the ABAQUS/Standard software program. The essential details of the structure geometry were taken from the 3D scan of the vault. The first variant of the masonry vault was the structure without any strengthening, wherea
APA, Harvard, Vancouver, ISO, and other styles
21

Ando, Wakako, Kazutaka Kamiya, Hideki Hayakawa, Masahide Takahashi, and Nobuyuki Shoji. "Comparison of Phakic Intraocular Lens Vault Using Conventional Nomogram and Prediction Formulas." Journal of Clinical Medicine 9, no. 12 (2020): 4090. http://dx.doi.org/10.3390/jcm9124090.

Full text
Abstract:
This study aimed to compare the achieved vault using a manufacturer’s nomogram and the predicted vault using the currently available prediction formulas after posterior chamber phakic intraocular lens (EVO Implantable Collamer Lens; ICL, STAAR Surgical) implantation. We included 200 eyes of 100 consecutive patients (mean age ± standard deviation, 34.3 ± 7.8 years) undergoing ICL implantation with a central hole. Three months postoperatively, we quantitatively measured the actual vault, and we compared it with the predicted vault using anterior segment optical coherence tomography (CASIA 2, Tom
APA, Harvard, Vancouver, ISO, and other styles
22

Laila, Alif, Fahmida Chowdhury, Mst Taslima Akter, Sharmin Siddika, and Iffat Ara. "Use of vault drainage for reducing vault haematoma during vaginal hysterectomy." Bangladesh Medical Journal 45, no. 3 (2017): 121–25. http://dx.doi.org/10.3329/bmj.v45i3.33118.

Full text
Abstract:
A hysterectomy may be performed via abdominal, vaginal, or laparoscopic-assisted abdominal or vaginal approaches. Vaginal hysterectomy is associated with lower morbidity, faster recovery and shorter hospital stay compared with abdominal hysterectomy and should be considered the First choice for all benign conditions. But it is associated with a signi_cant risk of vault haematomas. Considering all the measures taken to reduce haematoma formation, vault drainage may help to reduce the postoperative complications and morbidity. The role of drain in abdominal surgery is well recognised. However, n
APA, Harvard, Vancouver, ISO, and other styles
23

Kedersha, N. L., J. E. Heuser, D. C. Chugani, and L. H. Rome. "Vaults. III. Vault ribonucleoprotein particles open into flower-like structures with octagonal symmetry." Journal of Cell Biology 112, no. 2 (1991): 225–35. http://dx.doi.org/10.1083/jcb.112.2.225.

Full text
Abstract:
The structure of rat liver vault ribonucleoprotein particles was examined using several different staining techniques in conjunction with EM and digestion with hydrolytic enzymes. Quantitative scanning transmission EM demonstrates that each vault particle has a total mass of 12.9 +/- 1 MD and contains two centers of mass, suggesting that each vault particle is a dimer. Freeze-etch reveals that each vault opens into delicate flower-like structures, in which eight rectangular petals are joined to a central ring, each by a thin hook. Vaults examined by negative stain and conventional transmission
APA, Harvard, Vancouver, ISO, and other styles
24

Motoshima, Yoshie, and Akira Maeda. "KASAMATSU VERSUS TSUKAHARA VAULT." Science of Gymnastics Journal 7, no. 2 (2015): 15–24. https://doi.org/10.52165/sgj.7.2.15-24.

Full text
Abstract:
In the gymnastics vault, many male gymnasts presently perform vaulting of the Kasamatsu type in competitions. The purpose of this study was to clarify the characteristics of the vaulting motion of the Kasamatsu vault in comparison with the Tsukahara vault. Six male college gymnasts performed the Kasamatsu and Tsukahara vaults. Their vaulting motion was captured by the 3-dimensional optical motion capture system MAC3D. For both the Kasamatsu and Tsukahara vaults, horizontal velocity of the center of mass decreased, vertical velocity increased, and angular momentum was produced in the board cont
APA, Harvard, Vancouver, ISO, and other styles
25

Vaught, Sabina. "Institutional Racist Melancholia: A Structural Understanding of Grief and Power in Schooling." Harvard Educational Review 82, no. 1 (2012): 52–77. http://dx.doi.org/10.17763/haer.82.1.e3p454q1070131g4.

Full text
Abstract:
In this article, Sabina Vaught undertakes the theoretical and analytical project of conceptually integrating Whiteness as property, a key structural framework of Critical Race Theory (CRT), and melancholia, a framework originally emerging from psychoanalysis. Specifically, Vaught engages Whiteness as property as an analytic tool to examine data from a larger ethnographic study of juvenile prison and schooling. She suggests that the psychoanalytic framework of melancholia enriches and complicates this analysis and proposes a theoretical move toward understanding structural affective processes i
APA, Harvard, Vancouver, ISO, and other styles
26

Kickhoefer, Valerie A., Yie Liu, Lawrence B. Kong, et al. "The Telomerase/Vault-Associated Protein Tep1 Is Required for Vault RNA Stability and Its Association with the Vault Particle." Journal of Cell Biology 152, no. 1 (2001): 157–64. http://dx.doi.org/10.1083/jcb.152.1.157.

Full text
Abstract:
Vaults and telomerase are ribonucleoprotein (RNP) particles that share a common protein subunit, TEP1. Although its role in either complex has not yet been defined, TEP1 has been shown to interact with the mouse telomerase RNA and with several of the human vault RNAs in a yeast three-hybrid assay. An mTep1−/− mouse was previously generated which resulted in no apparent change in telomere length or telomerase activity in six generations of mTep1-deficient mice. Here we show that the levels of the telomerase RNA and its association with the telomerase RNP are also unaffected in mTep1−/− mice. Al
APA, Harvard, Vancouver, ISO, and other styles
27

Liu, Li, Ji He Zhou, and Zhan Le Gao. "Research on Computer System Collecting the Vault Techniques." Applied Mechanics and Materials 401-403 (September 2013): 1474–79. http://dx.doi.org/10.4028/www.scientific.net/amm.401-403.1474.

Full text
Abstract:
we protocol to research and develop sport biomechanics quick response system for vault technical training, which quick analyzes vault techniques of athletes by using pressure plate on vault board to collect data of step position and strength, combined with synchronous acquisition of coxa joint kinematic parameters. This is helpful to improve the technical training effective of vault gymnast.
APA, Harvard, Vancouver, ISO, and other styles
28

Stewart, P. L., L. B. Kong, A. C. Siva, V. A. Kickhoefer, L. Harrington, and L. H. Rome. "Single Particle Reconstruction of the Vault from TEP1 Knockout Mice and Refinement of the Computationally Selected Vault Barrel." Microscopy and Microanalysis 6, S2 (2000): 268–69. http://dx.doi.org/10.1017/s1431927600033833.

Full text
Abstract:
The vault complex is a ubiquitous and predominantly cytoplasmic 13 MDa ribonucleoprotein assembly, composed of three proteins (TEP1, 240 kDa; VPARP, 193 kDa; and MVP, 100 kDa) and an untranslated RNA (vRNA) Although the basic cellular function of the vault is still unclear, recently it has been shown that induction of the major vault protein (MVP) has a direct negative influence on the nuclear uptake of the anti-cancer drug, doxorubicin. We have been applying cryo-EM single particle reconstruction methods to study the structure and molecular architecture of this cellular component. A published
APA, Harvard, Vancouver, ISO, and other styles
29

Thakur, Ashish, and Amit Saxena. "Improved Vault based Tokenization to Boost Vault Lookup Performance." International Journal of Computer Applications 177, no. 21 (2019): 24–32. http://dx.doi.org/10.5120/ijca2019919666.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Pollock, Richard A. "Acute nasal fractures: Vault-by-vault assessment and repair." Operative Techniques in Plastic and Reconstructive Surgery 5, no. 3 (1998): 223–35. http://dx.doi.org/10.1016/s1071-0949(98)80015-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

Ross, J. W. "Apical vault repair, the cornerstone or pelvic vault reconstruction." International Urogynecology Journal 8, no. 3 (1997): 146–52. http://dx.doi.org/10.1007/bf02764847.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Karki, Gyanendra Man Singh, BB Neupane, MC Regmi, R. Shrestha, and SN Gupta. "Vaginal Cuff Dehiscence after Hysterectomy and One Minute Technique of Laparoscopic Vault Closure." Nepal Journal of Obstetrics and Gynaecology 11, no. 2 (2017): 8–11. http://dx.doi.org/10.3126/njog.v11i2.17450.

Full text
Abstract:
Aims: This study was done to observe the rate of vaginal cuff dehiscence of one minute technique of laparoscopic vault closure in laparoscopic hysterectomy.Methods: It was a descriptive study performed in Birat Hospital among 1012 patients undergoing total laparoscopic hysterectomy for both benign and malignant gynaecological conditions between 2012 to 2013. Monopolar cautery was used for laparoscopic colpotomy and vault was closed by laparoscopic single running suture, that is, one-minute laparoscopic vault closure technique. Patients were followed up for vaginal cuff dehiscence and the dehis
APA, Harvard, Vancouver, ISO, and other styles
33

Zhou, Ji He, Zhan Le Gao, Yi Liu, and Li Liu. "Biomechanics Quick Response System Research of Vault Technical Training." Applied Mechanics and Materials 457-458 (October 2013): 405–9. http://dx.doi.org/10.4028/www.scientific.net/amm.457-458.405.

Full text
Abstract:
We protocol to research and develop sport biomechanics quick response system for vault technical training, which quick analyzes vault techniques of athletes by using pressure plate on vault board to collect data of step position and strength, combined with synchronous acquisition of coxa joint kinematic parameters. This is helpful to improve the technical training effective of vault gymnast. We use a regular camera to shoot the positive side of athletes. At the same time the pressure plate is placed on vault board to collect dynamic data. Use MATLAB as a development platform, and input the vid
APA, Harvard, Vancouver, ISO, and other styles
34

Kochkonyan, Taisiya, Ghamdan Al-Harazi, Dmitry Domenyuk, Sergei Dmitrienko, Milana Budaichieva, and Stanislav Domenyuk. "Clinical types of hard palatal vault in people with various gnathic dental arches within physiologically optimal norm." Archiv Euromedica 12, no. 1 (2022): 91–98. http://dx.doi.org/10.35630/2199-885x/2022/12/1.20.

Full text
Abstract:
The study is based on an analysis of conebeam computed tomograms and biometric examination of jaw cast models obtained from 68 people aged 21–35 with permanent teeth physiological occlusion. The findings were used to identify the relationship between the morphometric values (height, depth) of the palatal vault, and the linear parameters (length, width) of dental arches. In patients with mesognathic dental arches, the palatal vault index, taken as a ratio between the palate height to the alveolar part width, was 41.14 ± 2.87%, whereas the width indicators exceeded (by 2.43 times on average) the
APA, Harvard, Vancouver, ISO, and other styles
35

FERNANDES, Sarah Maria Boldrini, Paulo CARRARA, Júlio Cerca SERRÃO, Alberto Carlos AMADIO, and Luis MOCHIZUKI. "Kinematic variables of table vault on artistic gymnastics." Revista Brasileira de Educação Física e Esporte 30, no. 1 (2016): 97–107. http://dx.doi.org/10.1590/1807-55092016000100097.

Full text
Abstract:
Abstract The table vault is an event of male and female Artistics Gymnastics. Although it can be performed in a variety of rotations and body positions in different phases, it can be separated in three groups: handspring, Yurchenko and Tsukahara. It is believed that kinematic variables of vault may vary according to group of vault or gymnast body position, but few studies compares the real differences among the three groups of vaults, comparing and describing the variables in different phases. Vault kinematic variables could be diversifying according to the approach or position of the vaulting
APA, Harvard, Vancouver, ISO, and other styles
36

Raj, Pritish. "Continuous Integration for New Service Deployment and Service Validation Script for Vault." INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT 08, no. 06 (2024): 1–5. http://dx.doi.org/10.55041/ijsrem35565.

Full text
Abstract:
Modern cloud-native applications demand robust security measures to safeguard sensitive data such as passwords, API keys, and encryption keys. Managing these secrets securely within Kubernetes clusters presents a significant challenge. In response, this project proposes a comprehensive solution leverag- ing HashiCorp Vault, Kubernetes, and Docker to enhance secret management and strengthen overall security posture.HashiCorp Vault serves as a centralized secrets management tool, provid- ing encryption, access control, and auditing functionalities. By integrating Vault with Kubernetes, secrets c
APA, Harvard, Vancouver, ISO, and other styles
37

Di, Yu, Ying Li, and Yan Luo. "Prediction of Implantable Collamer Lens Vault Based on Preoperative Biometric Factors and Lens Parameters." Journal of Refractive Surgery 39, no. 5 (2023): 332–39. http://dx.doi.org/10.3928/1081597x-20230207-03.

Full text
Abstract:
Purpose: To establish and validate the accuracy of implantable collamer lens (ICL) vault size prediction formula based on preoperative biometric factors and lens parameters. Methods: This study included 300 patients (300 eyes) with Visian ICL V4c (STAAR Surgical) implantation. They were randomly divided into the formula establishment group and formula validation group. Anterior segment measurements, ICL V4c size and power, and vault 1 week postoperatively were collected from all patients. Multiple linear regression analysis was performed to establish the prediction formula. Mean absolute error
APA, Harvard, Vancouver, ISO, and other styles
38

Motoshima, Yoshie, Junichi Kitagawa, and Akira Maeda. "THE RELATIONSHIP BETWEEN THE MECHANICAL PARAMETERS IN THE TAKE-OFF OF A VAULT AND THE DROP JUMP ABILITY." Science of Gymnastics Journal 7, no. 3 (2015): 37–45. https://doi.org/10.52165/sgj.7.3.37-45.

Full text
Abstract:
In the vault in gymnastics, the take-off motion is important to the success of the vault and to perform more difficult vaults. Vaulting ability has been studied by motion analysis, but this method is not effective for easy evaluation. Therefore, the purpose of this study was to investigate the relationship between the mechanical parameters in the take-off of a vault and the drop jump ability, by focusing on the rebound drop jump index (RDJ index) calculated from the two variables of contact time and flight time. Male gymnasts performed the Kasamatsu vault, and their vaulting motion was capture
APA, Harvard, Vancouver, ISO, and other styles
39

D’Almeida, Sandhya, and Diana Lobo. "A Case Report on Vaginal Vault Prolapse." International Journal of Scientific Research 3, no. 6 (2012): 413–14. http://dx.doi.org/10.15373/22778179/june2014/139.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

Lee, Dae-Jong, Chang-Kyu Song, Sung-Moo Park, and Myung-Geun Chun. "Real Fuzzy Vault for Protecting Face Template." Journal of Korean Institute of Intelligent Systems 23, no. 2 (2013): 113–19. http://dx.doi.org/10.5391/jkiis.2013.23.2.113.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Grkovic, Vladan, Milan Kolarevic, Miomir Vukicevic, and Miso Bjelic. "Automatic configuration of modular vault walls." Facta universitatis - series: Architecture and Civil Engineering 10, no. 3 (2012): 291–300. http://dx.doi.org/10.2298/fuace1203291g.

Full text
Abstract:
Products such as modular partition walls of vault rooms (with or without vault doors) are made at the request of the client who chooses the safety degree and provides the available dimensions of the wall that should be made. Modular construction of vault walls is the system of construction of industrially made elements which are composed in situ, which allows design of products adjusted to individual requirements of clients. Since the vault wall modules repeat in every new project and since they differ only by their number and dimensions, the use of modern CA (Computer Aided) tools and the pos
APA, Harvard, Vancouver, ISO, and other styles
42

Lindskog, Annika J. "Saving Lucia by Anna Vaught." James Joyce Quarterly 58, no. 1-2 (2020): 221–23. http://dx.doi.org/10.1353/jjq.2020.0046.

Full text
APA, Harvard, Vancouver, ISO, and other styles
43

Gissinger, Bastien. "Fouras (Charente-Maritime). Fort Vauban." Archéologie médiévale, no. 42 (December 1, 2012): 290. http://dx.doi.org/10.4000/archeomed.11058.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Latournerie, Marie-Aimée. "L’élection de Vézelay selon Vauban." Tribonien N° 7, no. 2 (2024): 138–47. http://dx.doi.org/10.3917/trib.007.0138.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Giebisch, Antonia. "Ergebnisse der VAUNET-Mediennutzungsanalyse 2024." merz | medien + erziehung 69, no. 3 (2025): 3–4. https://doi.org/10.21240/merz/2025.03.02.

Full text
Abstract:
In den vergangenen Jahren lässt sich ein kontinuierlicher Bedeutungszuwachs von Audio- und audiovisuellen Inhalten in der Alltagsmediennutzung der Bevölkerung feststellen. Laut der VAUNET-Mediennutzungsanalyse 2024 entfallen darauf durchschnittlich 9 Stunden und 38 Minuten pro Tag (88,5 % der gesamten Mediennutzungszeit). Die durchschnittliche Gesamtmediennutzung in Deutschland beläuft sich auf 10 Stunden und 53 Minuten pro Tag. Die Nutzung audiovisueller Medien lässt sich in verschiedene Angebotsformen differenzieren. Im Durchschnitt verbringen Bürger*innen in Deutschland täglich 5 Stunden un
APA, Harvard, Vancouver, ISO, and other styles
46

Laptev, B. V., A. B. Lapteva, and A. Y. Renzyak. "Experience of phakic lens implantation for the correction of myopia and astigmatism: feature of preoperative examination and lens parameters." Fyodorov journal of ophthalmic surgery, no. 2 (June 21, 2023): 6–12. http://dx.doi.org/10.25276/0235-4160-2023-2-6-12.

Full text
Abstract:
Purpose. To evaluate postoperative vault parameters – from the posterior surface of the phakic posterior intraocular lens (PIOL) to the anterior surface of the lens, its correlation with the preoperative data study and the choice of the PIOL size. Material and methods. This research was based on the retrospective analysis of 128 eyes (64 patients) for the period from February 2019 to May 2021. The age of patients varied from 21.0 to 42.0 29.5±5.5 (mean 29.5±5.5) years. All patients underwent PIOL implantation with Staar EVO Visian ICL (V4C) PIOL. The follow-up period ranged between 3 to 24 mon
APA, Harvard, Vancouver, ISO, and other styles
47

Zhou, Jianguang, Decai Qiu, Shangqu Sun, et al. "Settlement Prediction Method of Extra-Large Diameter Tunnels in Soft Rock Strata." Advances in Civil Engineering 2023 (April 8, 2023): 1–12. http://dx.doi.org/10.1155/2023/5558160.

Full text
Abstract:
This research was undertaken to predict the result of vault settlement during the excavation of super-large-span tunnels in soft rock strata, which are prone to deformation and hard to predict aftermaths. Numerical simulation was applied to tackle with vault problems during excavation of super-large-span soft rock tunnels such as proneness to deformation and hard prediction on vault settlement. As a result, a model for continuous prediction of vault settlement as the tunnel face keeps advancing was proposed, with influencing factors such as excavation span and tunnel depth taken into considera
APA, Harvard, Vancouver, ISO, and other styles
48

Nishimura, Mayuko, Chie Tachiki, Taiki Morikawa, et al. "Cranial Vault Deformation and Its Association with Mandibular Deviation in Patients with Facial Asymmetry: A CT-Based Study." Diagnostics 15, no. 13 (2025): 1702. https://doi.org/10.3390/diagnostics15131702.

Full text
Abstract:
Background/Objectives: Facial asymmetry is known to cause not only deformities in the facial skeleton but also alterations in the cranial vault. However, limited research has explored the association between mandibular asymmetry and cranial vault deformation. This study aimed to evaluate the three-dimensional craniofacial morphology, including the cranial vault, in patients with skeletal mandibular prognathism using computed tomography (CT) imaging. Methods: Patients were classified into two groups: those with facial asymmetry (ANB ≤ 0°, Menton deviation ≥ 4 mm) and those without (ANB ≤ 0°, Me
APA, Harvard, Vancouver, ISO, and other styles
49

Zhu, Yi, Jing Zhang, Haobin Zhu, Jili Chen, and Jibo Zhou. "The effect of mydriasis on moderate-to-high myopic eyes with implantable collamer lenses V4 and V4c." European Journal of Ophthalmology 30, no. 3 (2019): 462–68. http://dx.doi.org/10.1177/1120672119831218.

Full text
Abstract:
Purpose:To evaluate the vault change and anterior segment movement induced by mydriasis in moderate-to-high myopic eyes with implantable collamer lenses (ICL).Setting:Shanghai, ChinaDesign:A prospective consecutive observational study.Methods:A total of 45 eyes of 24 patients with ICL V4 implantation and 128 eyes of 65 patients with ICL V4c implantation were included and analyzed. Anterior chamber depth, posterior corneal endothelium-to-ICL distance, and vault before and after mydriasis were measured by Pentacam (Oculus, Wetzlar, Germany) at 1, 3, and 6 months after surgery.Results:Significant
APA, Harvard, Vancouver, ISO, and other styles
50

Yadav, Munjal, and Gehanath Baral. "Abdominal Sacro-Colpopexy Surgery for Vaginal Vault Prolapse at Nobel Medical College Teaching Hospital." Journal of Nobel Medical College 13, no. 2 (2024): 60–65. https://doi.org/10.3126/jonmc.v13i2.74461.

Full text
Abstract:
Background: Post-hysterectomy Vault prolapse is an uncommon late complication of hysterectomy. Women often experience restrictions in physical, emotional, and social functioning which decreases the overall quality of life. Vaginal vault prolapse can be treated by pelvic floor muscle training, pessary insertion, and surgery. Abdominal sacro-colpopexy is a procedure that surgically corrects vault prolapse using Prolene mesh to lift and hold the vaginal vault in the correct anatomical position. The study aimed to determine the success rate and complications of Abdominal sacro-colpopexy when perfo
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!