To see the other types of publications on this topic, follow the link: Ventilation Strategie.

Dissertations / Theses on the topic 'Ventilation Strategie'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 45 dissertations / theses for your research on the topic 'Ventilation Strategie.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

GUILLAUMONT, SOPHIE. "Strategie ventilatoire des enfants atteints de mucoviscidose : etude au repas et a l'exercice musculaire." Montpellier 1, 1991. http://www.theses.fr/1991MON11086.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Simon, Isabelle. "Interet d'un nouveau systeme d'analyse de la ventilation dans la strategie diagnostique du syndrome d'apnees du sommeil." Angers, 1994. http://www.theses.fr/1994ANGE1064.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Borges, João Batista. "Regional Lung Kinetics of Ventilator-Induced Lung Injury and Protective-Ventilation Strategies Studied by Dynamic Positron Emission Tomography." Doctoral thesis, Uppsala universitet, Hedenstiernalaboratoriet, 2014. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-230022.

Full text
Abstract:
Mechanical ventilation in itself can harm the lung and cause ventilator-induced lung injury (VILI), which can induce or aggravate acute respiratory distress syndrome (ARDS). Much debate remains over pivotal concepts regarding the pathophysiology of VILI, especially about the precise contribution, kinetics, and primary role of potential VILI mechanisms. Consequently, it remains largely unknown how best to design a well-timed and full-bodied mechanical ventilation strategy. Little is known also about small airways dysfunction in ARDS. Dynamic positron emission tomography (PET) with [18F]fluoro-2
APA, Harvard, Vancouver, ISO, and other styles
4

Cubí, Montanyà Eduard. "Energy efficient ventilation strategies for surgery rooms." Doctoral thesis, Universitat Politècnica de Catalunya, 2014. http://hdl.handle.net/10803/284903.

Full text
Abstract:
Surgery rooms are a space type with particularly stringent indoor environmental quality (IEQ) requirements, which translate into high energy use. Due to the unclear IEQ and infection control requirements for surgery rooms in Spain, these spaces are often designed and operated 24 hours per day and 7 days per week, to meet the most stringent recommendations (not only the requirements) in the available guidelines. While health and safety must remain top priority in hospitals, the high energy use of HVAC systems in surgery rooms makes these a clear energy efficiency target. The objective of this t
APA, Harvard, Vancouver, ISO, and other styles
5

Wong, Kit Iong. "ETS measurements and ventilation strategies for indoor environment." Thesis, University of Macau, 2008. http://umaclib3.umac.mo/record=b1942988.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Accili, Alessia. "Natural ventilation strategies for nearly – Zero Energy Sports Halls." Thesis, KTH, Energiteknik, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-200892.

Full text
Abstract:
In line with the article 9 of the EPDB, member states shall ensure that all new public properties are nearly zero energy buildings (n-ZEB) by December 31, 2018. Sports buildings account for a significant share of the European building stock consumption. More than half of their current energy needs are related to lighting, and a relevant energy use is due to domestic hot water. This work aims to test different energy measures to design nearly zero energy sports halls in Mediterranean climates. Under a holistic approach, the design of the base case sports hall includes the implementation of pass
APA, Harvard, Vancouver, ISO, and other styles
7

West, Aaron William. "An Exploration of the Natural Ventilation Strategies At the World Trade Center, Amsterdam." Thesis, Virginia Tech, 2000. http://hdl.handle.net/10919/35628.

Full text
Abstract:
The push to design environmentally conscious and sustainable buildings has surged over the past twenty year, thus leading to the development of new methods for harnessing the natural elements of the earth. In recent years the international firm of Kohn, Pederson and Fox has been a champion of the sustainability movement. In fact many of the newer passive ventilation strategies under development can be seen in Kohn, Pedersen Fox International (KPFI) current commission for the World Trade Center (WTC) currently under construction in Amsterdam, Netherlands. This multi-million square foot complex
APA, Harvard, Vancouver, ISO, and other styles
8

Robinson, Bryce RH M. D. "Implications of acute resuscitation and mechanical ventilation strategies upon pulmonary complications following injury." University of Cincinnati / OhioLINK, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1427882608.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Carbonare, Nicolas [Verfasser], and A. [Akademischer Betreuer] Wagner. "Occupant-centered control strategies for decentralized residential ventilation / Nicolas Carbonare ; Betreuer: A. Wagner." Karlsruhe : KIT-Bibliothek, 2021. http://d-nb.info/1238147844/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Santolini, Enrica <1989&gt. "Study of ventilation strategies, in agricultural buildings through CFD modeling and experimental analysis." Doctoral thesis, Alma Mater Studiorum - Università di Bologna, 2019. http://amsdottorato.unibo.it/8852/1/tesi_dottorato_ES.pdf.

Full text
Abstract:
Environmental control in agricultural and agro-industrial buildings is a very important and topical subject which falls within the domain of precision agriculture and smart food processing. There is a growing interest in the study of systems able to combine active and passive environmental control techniques and in the development of methodologies for modeling and simulating the environmental conditions in the agro-industrial sector. These ones need a process of validation and experimental calibration, but they can investigate specific aspects and variations of the thermo-fluidynamic phenomena
APA, Harvard, Vancouver, ISO, and other styles
11

McCrory, R. M. "Novel strategies for the prevention of ventilator - associated pneumonia." Thesis, Queen's University Belfast, 2004. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.411130.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Fuest, Sven [Verfasser]. "Protective signalling mechanisms in the lung induced by open-lung ventilation strategies / Sven Fuest." Gießen : Universitätsbibliothek, 2014. http://d-nb.info/106847453X/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Prajongsan, Pimolsiri. "Natural ventilation strategies to enhance human comfort in high-rise residential buildings in Thailand." Thesis, University of Liverpool, 2014. http://livrepository.liverpool.ac.uk/2006523/.

Full text
Abstract:
In this study a thermal comfort ventilation strategy called ‘ventilation shaft’, which is a vertical shaft located at the rear of a single-sided unit and with an exhaust at the building’s flat roof, is proposed for a single-sided residential unit in high-rise buildings in Bangkok. The main aim is to investigate its potential to maximize the unit’s indoor air velocity and to extend the occupants’ thermal comfort, which, therefore, reduces high electricity consumption due to cooling systems. By using the validated CFD code in DesignBuilder simulation software, the ventilation shaft’s effectivene
APA, Harvard, Vancouver, ISO, and other styles
14

Turner, Carolyn S. "Perceived thermal comfort and energy conservation strategies in residential heating." Diss., Virginia Polytechnic Institute and State University, 1985. http://hdl.handle.net/10919/49947.

Full text
Abstract:
The perception of thermal comfort is an important factor influencing the acceptability of residential heating strategies. The perceived thermal comfort may affect a person's inclination to try a strategy or to use it on a long-term basis. In the study, perceived thermal comfort was assessed in relation to room temperature, humidity, clothing worn, preferred room temperatures, personal control over the temperatures, and energy consumption. The relationships among these variables were examined for five families participating in a live-in study comparing five residential heating strategies. The s
APA, Harvard, Vancouver, ISO, and other styles
15

Kiamba, Lorna Ndanu. "Optimising environmental design strategies to improve thermal performance in office buildings in Kenya." Thesis, University of Nottingham, 2016. http://eprints.nottingham.ac.uk/33758/.

Full text
Abstract:
An examination of contemporary office buildings in the warm humid region of Kenya revealed the predominance of highly glazed lightweight buildings that are prone to overheating and rely on costly and unsustainable active climate control systems. In the midst of growing energy demand and a potential deficit in supply, the influx of these poorly designed buildings has intensified the need to explore viable climate-responsive design alternatives suitable to local conditions that can extend occupant comfort and reduce the need for energy intensive environmental control systems. This view is shared
APA, Harvard, Vancouver, ISO, and other styles
16

Rinaldi, Nicola. "Thermal Mass, Night Cooling and Hollow Core Ventilation System as Energy Saving Strategies in Buildings." Thesis, KTH, Byggnadsteknik, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-34855.

Full text
APA, Harvard, Vancouver, ISO, and other styles
17

Tucker, Brandon Raye. "Reducing the incidence of ventilator-associated pneumonia with selected positional strategies." Honors in the Major Thesis, University of Central Florida, 2010. http://digital.library.ucf.edu/cdm/ref/collection/ETH/id/1512.

Full text
Abstract:
This item is only available in print in the UCF Libraries. If this is your Honors Thesis, you can help us make it available online for use by researchers around the world by following the instructions on the distribution consent form at http://library.ucf.edu/Systems/DigitalInitiatives/DigitalCollections/InternetDistributionConsentAgreementForm.pdf You may also contact the project coordinator, Kerri Bottorff, at kerri.bottorff@ucf.edu for more information.<br>Bachelors<br>Nursing<br>Nursing
APA, Harvard, Vancouver, ISO, and other styles
18

Bobba, Christopher M. "Strategies to Model and Develop Therapeutics for Ventilator Induced Lung Injury." The Ohio State University, 2019. http://rave.ohiolink.edu/etdc/view?acc_num=osu1555505746014545.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Lugg, Andrew. "Energy and cost efficient fuzzy environmental services control strategies for achieving high standards of indoor environmental quality and human comfort." Thesis, Cranfield University, 1999. http://hdl.handle.net/1826/4198.

Full text
Abstract:
Building designers aim to create buildings with high quality internal environments which are energy and cost efficient in their use. Failure to attain these objectives simultaneously can lead to reduced building occupant productivities. An important aspect of the building services system which can have a major effect on the provision of occupant comfort within a building is the adopted control strategy. The research project investigated the use of fuzzy control strategies as a means of achieving good standards of comfort provision for occupants while maintaining or improving energy and cost ef
APA, Harvard, Vancouver, ISO, and other styles
20

Greth, August V. "Evaluating Mine Cooling Systems and Mine Ventilation Strategies to be Applied in Deep and Hot US Mines." Thesis, University of Nevada, Reno, 2018. http://pqdtopen.proquest.com/#viewpdf?dispub=10817148.

Full text
Abstract:
<p> Metal production in the United States contributes significantly to the national and global economies due to resource demands. As mineral reserves are becoming scarce, demand has driven mining companies to operate at increasing depths underground. Along with this, production has continued to increase year after year, as lower grade ores are excavated economically. However, the increased mining depths and increased production have resulted in enlarged heat loads in the underground mine environment. Increased heat loads can result in temperatures, which are too high for mine workers to safely
APA, Harvard, Vancouver, ISO, and other styles
21

Mohammed, Mohammed Alhaji. "Natural ventilation : an evaluation of strategies for improving indoor air quality in hospitals located in semi-arid climates." Thesis, University of Newcastle upon Tyne, 2015. http://hdl.handle.net/10443/2837.

Full text
Abstract:
This thesis is an investigation into improving natural ventilation in low rise hospital wards in Northern Nigeria. The climate of this region is semi-arid, during the dry season, sub-Saharan fine dust (Harmattan dust) is blown into the region from the North East and during the wet season, Mosquitos are prevalent. The energy infrastructure in the whole of Nigeria is under resourced; hence ventilation strategies’ based on mechanical extraction are not possible. Five wards within low rise hospital buildings were studied; these were purpose designed hospital buildings, not converted buildings. Que
APA, Harvard, Vancouver, ISO, and other styles
22

Navidi, Parisa. "Inspiration By Nature: Biomimetic Research Informs Adaptable Building Skin System for Natural Ventilation and Daylight in Hot Dry Climate (Yazd, Iran)." DigitalCommons@CalPoly, 2014. https://digitalcommons.calpoly.edu/theses/1158.

Full text
Abstract:
Many plant species, including Barrel Cacti, have developed long-term evolutionary adaptable traits to survive in extreme climates. The most important trait of cacti in extreme hot dry climates is to reduce water evaporation and increase water storage. The exterior skin of a cactus plays an important role in preventing water evaporation through heat transmission. On the other hand, there have been many passive design strategies applied to the space planning and building design of architecture in hot dry climates. The goal of these passive design strategies is to regulate the penetration of heat
APA, Harvard, Vancouver, ISO, and other styles
23

Kolín, Jan. "Strategická koncepce firmy Bristec CZ, s.r.o." Master's thesis, Vysoká škola ekonomická v Praze, 2010. http://www.nusl.cz/ntk/nusl-74934.

Full text
Abstract:
The diploma thesis Strategic concept of company Bristec cz s.r.o. analyses and evaluates company's position in the market and searches opportunities for future development. The thesis is divided into theoretical and application part, which is then divided according to business activity of the company. Terms as mission, vision and goals and explained in the theoretical part. Principles of strategic management and conduction of strategic analysis are also described. Types of strategy from renowned authors and specifications of family companies are then introduced. The theoretical part furthermor
APA, Harvard, Vancouver, ISO, and other styles
24

Hancerli, Mustafa Yilmaz. "Appropriate Passive Cooling Strategies For Hot And Humid Climates: A Case Study In Cyprus." Master's thesis, METU, 2008. http://etd.lib.metu.edu.tr/upload/12609401/index.pdf.

Full text
Abstract:
In this study, energy conservation potential of appropriate passive cooling and basic heat avoidance strategies were investigated for hot and humid climates. Within this framework, thermal behavior of a case study building that is situated in Cyprus was assessed by collecting temperature and relative humidity data from various rooms of the building during certain days in August. Then, by using feasible simulation strategies of the software tool Summer-Building, the effectiveness of passive cooling measures in reducing energy consumption were examined, for summer months. In this context, the ca
APA, Harvard, Vancouver, ISO, and other styles
25

Rossi, Michele Marta. "Regression models to assess the thermal performance of Brazilian low-cost houses: consideration of natural ventilation." Universidade de São Paulo, 2016. http://www.teses.usp.br/teses/disponiveis/102/102131/tde-13102016-163056/.

Full text
Abstract:
Building performance simulations [BPS] tools are important in all the design stages, mainly in the early ones. However, some barriers such as time, resources and expertise do not contribute to their implementation in architecture offices. This research aimed to develop regression models (meta-models) to assess the thermal discomfort in a Brazilian low-cost house [LCH] during early design. They predicted the degree-hours of discomfort by heat and/or by cold as function of the design parameters changes for three Brazilian cities: Curitiba/PR, São Paulo/SP, and Manaus/AM. This work focused on usi
APA, Harvard, Vancouver, ISO, and other styles
26

Jamriska, Milan. "The effect of ventilation and air filtration on reduction of indoor concentration to submicrometer airborne particulates." Thesis, Queensland University of Technology, 2000.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
27

Tanned, Susanne, and Robert Törnqvist. "Intraoperativa strategier för att hantera ventilationen hos den vuxne obese patienten som genomgår laparoskopisk kirurgi i generell anestesi." Thesis, Örebro universitet, Institutionen för hälsovetenskaper, 2020. http://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-84193.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Dhalluin, Adrien. "Etude de stratégies de ventilation pour améliorer la qualité environnementale intérieure et le confort des occupants en milieu scolaire." Phd thesis, Université de La Rochelle, 2012. http://tel.archives-ouvertes.fr/tel-00823905.

Full text
Abstract:
La ventilation est un secteur clé du bâtiment, dont le rôle est d'assurer un air sain et confortable toute l'année, ce qui est rarement le cas dans les bâtiments scolaires, tout en minimisant les consommations énergétiques. Nos travaux consistent à apporter des éléments de réponses et des pistes d'amélioration pour l'élaboration de stratégies de ventilation appropriées au milieu scolaire, à partir de travaux expérimentaux et numériques. Pour ce faire, quatre modes de ventilation (naturelle et mixte) ont été testés dans des salles de classes de l'Université de La Rochelle, et leurs performances
APA, Harvard, Vancouver, ISO, and other styles
29

Salah, Heba. "Muscle Wasting in a Rat ICU Model : Underlying Mechanisms and Specific Intervention Strategies." Doctoral thesis, Uppsala universitet, Klinisk neurofysiologi, 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-328596.

Full text
Abstract:
Critical care has undergone several developments in the recent years leading to improved survival. However, acquired muscle weakness in the intensive care unit (ICU) is an important complication that affects severely ill patients and can prolong their ICU stay. Critical illness myopathy (CIM) is the progressive decline in the function and mass of the limb muscles in response to exposure to the ICU condition, while ventilator-induced diaphragm dysfunction (VIDD) is the time dependent decrease in the diaphragm function after the initiation of mechanical ventilation. Since the complete underlying
APA, Harvard, Vancouver, ISO, and other styles
30

Castro, Renata Torres Sarmento de. "Avaliação do desempenho da ventilação natural e do sombreamento em casas de Maceió projetadas segundo princípios abordados na cartilha de Armando de holanda." Universidade Federal de Alagoas, 2011. http://repositorio.ufal.br/handle/riufal/728.

Full text
Abstract:
This survey deals with the dimensionality of the natural ventilation and its fitness to building houses in the Brazilian Northeast. It is a case study due to the limited sample of the object evaluated, since that its abridgement involved only two houses located in Maceió city in the state of Alagoas. As matter of fact, by the end of 1970 through 1980, a pernambucano architect under the name of Armando de Holanda wrote a booklet guide containing 9 (nine) bioclimatic strategies to solve the problem of the hot and damp ventilation that reaches the tropical regions causing distress to their inhabi
APA, Harvard, Vancouver, ISO, and other styles
31

Partlová, Jana. "Hodnocení ekonomické situace vybrané soukromoprávní korporace a návrhy na její zlepšení." Master's thesis, Vysoké učení technické v Brně. Fakulta podnikatelská, 2019. http://www.nusl.cz/ntk/nusl-399661.

Full text
Abstract:
This thesis deals with the analysis of VENTILÁTORY, s.r.o. 2013-2017. The selected methods of economic and strategic analysis evaluate the internal and external environment of the company and its financial situation. Based on the results obtained from the analyzes, measures have proposed that lead to the improvement of the identified status.
APA, Harvard, Vancouver, ISO, and other styles
32

Schutte, Abraham Jacobus. "An integrated energy efficiency strategy for deep mine ventilation and refrigeration / Abraham Jacobus Schutte." Thesis, 2014. http://hdl.handle.net/10394/12198.

Full text
Abstract:
South Africa’s electricity supply is under pressure. Mining is one of South Africa’s largest electricity consumers with electricity-intensive services such as compressed air, cooling, ventilation, etc. More than 40% of mine electricity consumption is used for cooling and ventilation. There is a need to reduce the operational cost on a mine as electricity prices are set to increase at least 2% above South Africa’s inflation target. The mine-cooling and ventilation system was investigated for energy cost-saving. No clear energy and cost-saving strategy for the entire mine-cooling and ventilation
APA, Harvard, Vancouver, ISO, and other styles
33

Otáhal, Michal. "Biomechanický model interakce ventilace a oběhu za podmínek umělé plicní ventilace." Doctoral thesis, 2019. http://www.nusl.cz/ntk/nusl-406244.

Full text
Abstract:
MUDr. Michal Otáhal Biomechanický model interakce oběhu a ventilace za podmínek UPV Abstract: Conventional mechanical ventilation provides gas exchange in conditions of respiratory failure by application positive airway pressure in the respiratory system. Due to the significant change in pressure conditions inside the thorax during conventional artificial ventilation the circulation can be significantly affected. Recruitment maneuver (RM) techniques can be a part of ventilation strategy in patients with the Acute Respiratory Distress Syndrome (ARDS), that are used to re-aerate collapsed parts
APA, Harvard, Vancouver, ISO, and other styles
34

GAI, GIORDANA. "Quantitative fire risk assessment of road tunnels through advanced consequence analysis." Doctoral thesis, 2018. http://hdl.handle.net/11573/1079224.

Full text
Abstract:
The thesis is focused on the fire risk in road tunnels and its numerical estimation through quantitative risk analysis (QRA) supported by fire and evacuation modeling. According to the in-force regulations concerning the Trans-European Road Network, the quantitative risk assessment is a mandatory step for existing tunnels that do not comply with the minimum structural safety requirements. When the risk does not reach the acceptability threshold, alternative configurations and mitigation strategies must be designed to reduce the residual risk under a suitable level, and again the QRA is usefu
APA, Harvard, Vancouver, ISO, and other styles
35

Chang, Yu-Hao, and 張育豪. "The simulation of ventilation strategies for crop and architectural arrangement." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/42581895550531039971.

Full text
Abstract:
碩士<br>國立屏東科技大學<br>車輛工程系所<br>103<br>The efficiency of ventilation in the greenhouse is determined by the external environment and the structure of the greenhouse. In order to enhance the use of the resource and reduce the waste of energy. A simulation model by CFD was established in this study to assist in designing ventilation system.Because of the influence of window structure, air flow is rapid and concentrated when through the window. The average velocity of the district where closer the windward window is higher than farther ones. On the contrary, the uniformity of velocity in the area bec
APA, Harvard, Vancouver, ISO, and other styles
36

Lee, Shiun-Kuu, and 李訓谷. "The Analysis of Ventilation System Energy Saving and Intelligent Control Strategies." Thesis, 1995. http://ndltd.ncl.edu.tw/handle/17269180153527856695.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Huang, Chiung-Hui, and 黃瓊慧. "The effect of treatment strategies on ventilation/ perfusion mismatch during hypovolemic shock." Thesis, 2008. http://ndltd.ncl.edu.tw/handle/68813463543595503530.

Full text
Abstract:
碩士<br>國防醫學院<br>海底醫學研究所<br>96<br>Background: Hypovolemic shock leads to hypoperfusion, which causes inadequate oxygen delivery to tissues and requirement. Under the physiological compensation, the increase oxygen supply or tissues oxygen extraction, can increase the arterial blood oxygen content, but whether improved the pulmonary ventilation-perfusion distribution , still is unknown. In clinical practice, the whole blood transfusion and Norepinephrine therapy improve the systemic hemodynamic change. The former elevated blood volume, the latter increases vascular resistance, both have that was
APA, Harvard, Vancouver, ISO, and other styles
38

Lan, Wei-En, and 藍偉恩. "A Strategic Study on Hybrid Ventilation and Noise Reduction of a Large Hall Space." Thesis, 2015. http://ndltd.ncl.edu.tw/handle/36669377218061126365.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>建築系<br>104<br>As the trend of building sustainability in recent years, the design requirements of architectural acoustics performance increased. Effective natural or hybrid ventilation system is helpful to reduce air-conditioning energy consumption. On the other hand, natural ventilation strategies challenged the common practice in acoustic design. Case studies on building acoustic solutions associated with natural ventilation were reviewed with a large auditorium that induces heat evacuation. Carry out the hall interior space flow field simulation by analysis using CFD metho
APA, Harvard, Vancouver, ISO, and other styles
39

Zaatari, Marwa. "Pollutant control strategies for acceptable indoor air quality and energy efficiency in retail buildings." Thesis, 2013. http://hdl.handle.net/2152/23305.

Full text
Abstract:
Indoor air is associated with substantial health risks and is estimated to be responsible for the loss of over 4.7 million healthy life years (years lost due to morbidity and mortality) annually in the U.S. The highest indoor air-related health benefits can be expected from policies and strategies that efficiently target pollutants having the greatest contribution to the burden of disease. This burden is caused by indoor sources as well as by outdoor pollutants transported to the indoors. The diversity of pollutants, pollutant sources, and the resulting health effects challenge the comparison
APA, Harvard, Vancouver, ISO, and other styles
40

Wu, Yu-Hsun, and 吳昱勳. "Computer Simulation and Full-scale Experiment of Optiomal Ventilation Strategies on Building Energy Conservation Designs in Kaohsiung Area." Thesis, 2009. http://ndltd.ncl.edu.tw/handle/u39eq7.

Full text
Abstract:
碩士<br>國立中山大學<br>機械與機電工程學系研究所<br>97<br>In recent years, HVAC systems of commercial buildings imposed heavy load on power demand, especially during summertime on-peak periods. The HVAC power consumption of commercial buildings usually accounts for 40% of total which indicated huge potential for energy-savings if proper operation strategies can be implemented. In this research, three different operational strategies were studied in an attempt to conserve energy, namely: the Night Purge, Free Cooling,and Pre-cooling. They were simulated , under the local weather conditions, and then validated with
APA, Harvard, Vancouver, ISO, and other styles
41

Lin, Ming-tse, and 林明澤. "The Application of Natural Ventilation Strategies for Architectural Design in Hot-humid ClimatePreliminary Design of College of Design Building in NTUST." Thesis, 2010. http://ndltd.ncl.edu.tw/handle/50465991536694923225.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>建築系<br>98<br>Situated in a humid environment, Taiwan’s passive high-performance architectural design can benefit much from the application of natural ventilation. However, the air current of urban wind field is hard to predict. Conventional architectural design approach does not yet process a capable tool to capture this phenomenon. Thus, the integration of natural ventilation design strategy with conventional building design process remains a difficult task. In view of this, this study seeks to discuss the early stage of architectural design with the ventilation design strat
APA, Harvard, Vancouver, ISO, and other styles
42

Yeh, Yi-Ling, and 葉怡伶. "Emergency Response and Rescue Strategies for Road Tunnel Fires of Combined Effect of Water Spray and Tunnel Ventilation Systems of Dongao Tunnel." Thesis, 2018. http://ndltd.ncl.edu.tw/handle/72h36y.

Full text
Abstract:
碩士<br>中央警察大學<br>消防科學研究所<br>106<br>This study is based on "evacuation safety theory" and it explores the effect of water spray system and ventilation system on emergency rescue of tunnel fires. Should a fire hazard occur, the unique dimension of long road tunnels may create an environment that is difficult in evacuation and rescue of personnel. In recent years, water spray systems have been set up for the protection of long tunnels in Taiwan, such as the Dongao tunnel in Su-Hua Highway and the Caopu tunnel in South Bound Highway. Besides, with the interaction of water spray system and ventilati
APA, Harvard, Vancouver, ISO, and other styles
43

IMANI, AMIR. "The reappearance of iranian vernacular architecture using natural ventilation and passive cooling strategies to improve conditions for food security and education in developing countries with hot climates." Doctoral thesis, 2019. http://hdl.handle.net/11573/1232195.

Full text
Abstract:
ABSTRACT : The largest problem facing human beings today is global warming. Every day, due to heavy consumption of petroleum and nuclear products, a huge amount of electricity is used. This electricity, in turn, fuels the global industry that produces cooling and warming systems for buildings, and this worrying reality has created a lot of biological disasters by adding pollution to our environment, including the increase of greenhouse gas etc. Currently, seventy percent of developing countries are located in hot temperature climates. In addition to dealing with hot climate issues, these
APA, Harvard, Vancouver, ISO, and other styles
44

Malá, Irena. "Časná pooperační péče u pacienta s levostrannou mechanickou srdeční podporou HeartMate II." Master's thesis, 2013. http://www.nusl.cz/ntk/nusl-324071.

Full text
Abstract:
Author's name: Bc. Irena Malá School: Charles university, Prague 1st Faculty of Medicine Institut of Theory and Practice of Nursing Vídeňská 800, 140 59 Prague 4 - Krč Program: Health Care Administration Title: Early postoperative care of the patient with the left ventricular assist device HeartMate II Diploma thesis supervisor: PhDr. Hocková Jana, PhD. Number of pages: 170 Number of attachments: 41 Year: 2013 Key words: early postoperative care, hypotermia, blood transfusion, fluid resuscitation, perioperative cardiovascular dysfunction, pharmacologic support, ventricular assist device HeartM
APA, Harvard, Vancouver, ISO, and other styles
45

Coelho, Luís Miguel da Silva. "Influência da estratégia de ventilação no consumo energético de edifícios de serviços com utilização permanente e baixas cargas térmicas." Master's thesis, 2013. http://hdl.handle.net/10316/99773.

Full text
Abstract:
Dissertação de Mestrado em Engenharia Mecânica, especialidade de Energia e Ambiente, apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.<br>Os principais responsáveis pelo consumo de energia em edifícios não residenciais são os equipamentos instalados, a iluminação e o AVAC (aquecimento, ventilação e ar condicionado). Por sua vez, o consumo de energia pelos sistemas de AVAC depende de uma série de fatores, nomeadamente das características térmicas do edifício em questão, da estratégia de ventilação e da intensidade das cargas térmicas internas, sejam elas originadas pe
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!