To see the other types of publications on this topic, follow the link: Vitallium.

Journal articles on the topic 'Vitallium'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Vitallium.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Gore, David, Robert Q. Frazer, Robert E. Kovarik, and Juan E. Yepes. "Vitallium®." Journal of Long-Term Effects of Medical Implants 15, no. 6 (2005): 673–86. http://dx.doi.org/10.1615/jlongtermeffmedimplants.v15.i6.90.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Sadek, Sherif A., and Dina Elawady. "Impact of Removable Partial Denture Type on Patient Satisfaction and Abutment Survival Rate-RCT." Open Access Macedonian Journal of Medical Sciences 7, no. 15 (2019): 2513–19. http://dx.doi.org/10.3889/oamjms.2019.668.

Full text
Abstract:
BACKGROUND: Patient’s satisfaction and the preservation of abutments is the most important outcomes that the clinician seeks during fabrication of any dental treatment, especially when it is concerned with removable prosthodontic rehabilitation.
 AIM: The present study evaluates three different Removable Partial Denture (RPD) types restoring mandibular class II modification I edentulous cases with regards to patient’s satisfaction and abutments survival.
 METHODS: Forty-two partially edentulous patients were divided into three groups (Group I rehabilitated with Vitallium RPD, Group I
APA, Harvard, Vancouver, ISO, and other styles
3

Rodas Rivera, Ruddy. "Historia de la implantología y la oseointegración, antes y después de Branemark." Revista Estomatológica Herediana 23, no. 1 (2014): 39. http://dx.doi.org/10.20453/reh.v23i1.46.

Full text
Abstract:
En 1911 los traumatólogos inmovilizaban fracturas óseas con dispositivos de acero inoxidable con contenido férrico, teniendo como secuela la corrosión. En 1932 el Vitallium, una aleación exenta de hierro, fue considerada ideal, no corrosiva y biocompatible para estos  nes. En 1940 un estudio en fémur de gatos comparó la corrosión del vitallium (gold estándar) respecto a otros metales, entre ellos el titanio. Histológica y radiogrၠcamente el titanio produjo menos efecto inƒ amatorio y corrosivo comparado al vitallium. Este estudio describe la característica inédita del titanio de “soldarse”
APA, Harvard, Vancouver, ISO, and other styles
4

Saadat, Ehsan, John V. Tiberi, Dennis W. Burke, and Young-Min Kwon. "Smith-Petersen Vitallium Mold Arthroplasty." JBJS Case Connector 3, no. 4 (2013): e112. http://dx.doi.org/10.2106/jbjs.cc.m.00126.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Baker, J. F., M. H. Vioreanu, and H. A. Khan. "Smith-Petersen Vitallium mould arthroplasty." Journal of Bone and Joint Surgery. British volume 93-B, no. 9 (2011): 1285–86. http://dx.doi.org/10.1302/0301-620x.93b9.27374.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Ekstrand, K., and I. E. Ruyter. "Etching Patterns of Co-Cr Alloys for Bonded Cast Restorations." Journal of Dental Research 66, no. 9 (1987): 1479–84. http://dx.doi.org/10.1177/00220345870660091301.

Full text
Abstract:
Resin-bonded bridges may replace missing teeth and act as splints in periodontal treatment. The objective of this study was to investigate the etch pattern after electrolytic etching of selected Co-Cr alloys in hydrochloric acid and to assess the changes in alloy composition after different etching times. The alloys investigated were Vitallium, Wironit, Wironium, Nobilium Hard, and Niranium NN. Alloy specimens were electrolytically etched in a hydrochloric acid solution for 1, 2, 5, and 10 min. The etched specimens were examined in a light microscope and a scanning electron microscope (SEM). D
APA, Harvard, Vancouver, ISO, and other styles
7

Weisberger, Edward C., and Charly T. Nguyen. "Laryngotracheal Reconstruction Using a Vitallium Alloy Miniplate." Annals of Otology, Rhinology & Laryngology 105, no. 5 (1996): 363–66. http://dx.doi.org/10.1177/000348949610500506.

Full text
Abstract:
When stenosis of the larynx and trachea involves loss of anterior support, this is usually corrected by an autograft of costochondral cartilage or of hyoid bone anchored with suture material. This paper describes an alternative technique employing a Vitallium alloy miniplate placed anterior to the airway as a means for providing support. This is placed over a fascial or auricular cartilage graft. Together, they provide a smooth scaffold for mucosal migration. Thirteen patients were treated at Indiana University Medical Center between 1991 and 1993 by means of this technique. Ten of the 13 pati
APA, Harvard, Vancouver, ISO, and other styles
8

Rostoker, G., J. Robin, O. Binet, M. D. Vignon-Pennamen, and P. Mammoudy. "Cutaneous granuloma over a vitallium plate." Contact Dermatitis 16, no. 3 (1987): 175–78. http://dx.doi.org/10.1111/j.1600-0536.1987.tb01416.x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Andrew Hodge, W. "Vitallium-mold arthroplasty of the knee." Journal of Arthroplasty 6, no. 3 (1991): 195–97. http://dx.doi.org/10.1016/s0883-5403(06)80164-6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Merle, C., M. Vigan, D. Devred, P. Giradrdin, B. Adessi, and R. Laurent. "Generalized eczema from vitallium osteosynthesis material." Contact Dermatitis 27, no. 4 (1992): 257. http://dx.doi.org/10.1111/j.1600-0536.1992.tb03259.x.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Wallenböck, E., and M. Pötsch. "Radiusköpfchenprothese im Langzeitergebnis—Vitallium versus Silastic." Unfallchirurgie 20, no. 2 (1994): 115–18. http://dx.doi.org/10.1007/bf02588152.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Sargent, Larry A., and K. Dwayne Fulks. "Reconstruction of Internal Orbital Fractures with Vitallium Mesh." Plastic and Reconstructive Surgery 88, no. 1 (1991): 31–38. http://dx.doi.org/10.1097/00006534-199107000-00006.

Full text
APA, Harvard, Vancouver, ISO, and other styles
13

Ronsevié, Radmilo. "RECONSTRUCTION OF INTERNAL ORBITAL FRACTURES WITH VITALLIUM MESH." Plastic and Reconstructive Surgery 89, no. 6 (1992): 1176. http://dx.doi.org/10.1097/00006534-199206000-00038.

Full text
APA, Harvard, Vancouver, ISO, and other styles
14

Sengezer, Mustafa, and Richard C. Sadove. "Reconstruction of Midface Bone Defects with Vitallium Micromesh." Journal of Craniofacial Surgery 3, no. 3 (1992): 125–33. http://dx.doi.org/10.1097/00001665-199211000-00003.

Full text
APA, Harvard, Vancouver, ISO, and other styles
15

Sudhakar, K. V. "Investigation of failure mechanism in vitallium 2000 implant." Engineering Failure Analysis 12, no. 2 (2005): 257–62. http://dx.doi.org/10.1016/j.engfailanal.2004.05.005.

Full text
APA, Harvard, Vancouver, ISO, and other styles
16

Swanson, A. R., T. D. Braden, and J. A. McGehee. "Pyrolytic Carbon and Cobalt-Chromium Bone Liners Flexible Implant Arthropinlasty." Veterinary and Comparative Orthopaedics and Traumatology 01, no. 02 (1988): 64–67. http://dx.doi.org/10.1055/s-0038-1633166.

Full text
Abstract:
An in vivo evaluation was conducted on the ability of synthetic bone liners to protect the Swanson High Performance Silastic Finger Joints following 73 flexible arthroplasties in the rabbit stifle. Three different groups of synthetic bone liners were tested against a control group in which no bone liners were used. The implanted bone liners consisted of 48 full circumference liners fabricated from pyrolytic carbon, 34 full circumference and 32 partial circumference liners of a cobaltchromium alloy (Vitallium).
APA, Harvard, Vancouver, ISO, and other styles
17

Coughlin, Michael J., and Richard V. Abdo. "Arthrodesis of the First Metatarsophalangeal Joint with Vitallium Plate Fixation." Foot & Ankle International 15, no. 1 (1994): 18–28. http://dx.doi.org/10.1177/107110079401500105.

Full text
Abstract:
Forty-seven patients (58 feet) underwent first metatarsophalangeal joint fusion with a small Vitallium plate (Howmedica, Inc., Rutherford, NJ). Congruous joint surfaces were prepared with either cone-shaped or cup-shaped reamers. At an average follow-up of 19.2 months, 98% (57 feet) were successfully fused. Ninety-three percent (54 feet) noted good or excellent results. Plate removal was necessary in only 7% (4 feet) of cases. Complications included nonunion with plate breakage in 2% (1 foot) and delayed union in 2% (1 foot) of cases. This technique was useful and predictable in achieving succ
APA, Harvard, Vancouver, ISO, and other styles
18

Krizan, K. E., J. E. Laffoon, D. L. Zeitler, and S. Madison. "Surface evaluation of titanium and vitallium dental implants using SEM." Proceedings, annual meeting, Electron Microscopy Society of America 48, no. 4 (1990): 872–73. http://dx.doi.org/10.1017/s0424820100177490.

Full text
Abstract:
In recent years Titanium (Ti) has been the metal of choice for use as a dental implant material. Vitallium (Vi, and alloy composed of Co, Cr, Ni, and Fe) was considered in the past as an ideal implant material, but current studies show Ti is perhaps better tolerated by tissues in the oral cavity. The purpose of this study is to evaluate the surfaces of Ti and Vi endodontic endosseous implants (EEI) placed in a primate model for one year. In human clinical situations this type of dental implant is sometimes used to stabilize compromised teeth. Under intravenous general anestheisia four cynomolg
APA, Harvard, Vancouver, ISO, and other styles
19

Luhr, Hans-Georg. "Vitallium Luhr Systems for Reconstructive Surgery of the Facial Skeleton." Otolaryngologic Clinics of North America 20, no. 3 (1987): 573–606. http://dx.doi.org/10.1016/s0030-6665(20)31621-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Sudhakar, K. V., and Jyhwen Wang. "Fatigue Behavior of Vitallium-2000 Plus Alloy for Orthopedic Applications." Journal of Materials Engineering and Performance 20, no. 6 (2010): 1023–27. http://dx.doi.org/10.1007/s11665-010-9716-z.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Mahalingam, K., and D. Reidy. "SMITH-PETERSEN VITALLIUM MOULD ARTHROPLASTY: A 45-YEAR FOLLOW-UP." Journal of Bone and Joint Surgery. British volume 78-B, no. 3 (1996): 496–97. http://dx.doi.org/10.1302/0301-620x.78b3.0780496.

Full text
APA, Harvard, Vancouver, ISO, and other styles
22

Holm, R., and J. Ohnsorge. "ESCA-Untersuchungen zur Bildung und Wiederherstellung der Passivschicht auf Vitallium." Zeitschrift für Orthopädie und ihre Grenzgebiete 119, no. 05 (2008): 439–44. http://dx.doi.org/10.1055/s-2008-1053314.

Full text
APA, Harvard, Vancouver, ISO, and other styles
23

Campbell, Willis C., and James Rand. "THE CLASSIC: Interposition of Vitallium Plates in Arthroplasties of the Knee." Clinical Orthopaedics and Related Research 440, &NA; (2005): 22–23. http://dx.doi.org/10.1097/01.blo.0000187335.23465.20.

Full text
APA, Harvard, Vancouver, ISO, and other styles
24

Ulku, Cagatay Han, Mustafa Avunduk, and Yavuz Uyar. "Biocompatibility of Vitallium as Ossicular Reconstruction Material in the Middle Ear." Otolaryngology–Head and Neck Surgery 131, no. 2 (2004): P148. http://dx.doi.org/10.1016/j.otohns.2004.06.244.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Pan, Hai-Le, Haruhiko Akiyama, Keiichi Kawanabe, Koji Goto, Kazutaka So, and Takashi Nakamura. "Long-term survivorship analysis of hip arthroplasty with vitallium mold cup." Journal of Orthopaedic Science 15, no. 4 (2010): 459–62. http://dx.doi.org/10.1007/s00776-010-1499-4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
26

Leslie, Bruce M., Martin O'Malley, and Arthur A. Thibodeau. "A forty-three-year follow-up of a vitallium scaphoid arthroplasty." Journal of Hand Surgery 16, no. 3 (1991): 465–68. http://dx.doi.org/10.1016/0363-5023(91)90015-4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Unwin, A. J., and P. J. Stiles. "Early Failure of Titanium Alloy Femoral Components: A Quantitative Radiological Analysis of Osteolytic and Granulomatous Change." Journal of the Royal Society of Medicine 86, no. 8 (1993): 460–63. http://dx.doi.org/10.1177/014107689308600812.

Full text
Abstract:
Shot blasted titanium alloy femoral components with a coarse finish were withdrawn from use in 1987 following reports of early component failure. We reviewed all coarse titanium femoral stems used in primary total hip arthroplasty in our institution between 1985 and 1987 and compared them to a similar stem made of vitallium which was also used over the same period. We found that, at an average of 5.2 years following implantation, over two-thirds of titanium components were associated with endosteal lysis. In many of the cases the early lytic changes were asymptomatic with significant bone loss
APA, Harvard, Vancouver, ISO, and other styles
28

Thomas, R. H., M. Rademaker, N. J. Goddard, and D. D. Munro. "Severe eczema of the hands due to an orthopaedic plate made of Vitallium." BMJ 294, no. 6564 (1987): 106–7. http://dx.doi.org/10.1136/bmj.294.6564.106.

Full text
APA, Harvard, Vancouver, ISO, and other styles
29

Ulku, Cagatay Han, Mustafa Cihat Avunduk, Yavuz Uyar, and Hamdi Arbag. "Biocompatibility of vitallium as ossicular reconstruction material in the middle ear: experimental animal study." Acta Oto-Laryngologica 125, no. 1 (2005): 38–42. http://dx.doi.org/10.1080/00016480410018241.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Aslam, N., and W. J. Ribbans. "First metatarsophalangeal joint arthrodesis using a vitallium plate with a mean two year follow up." Foot and Ankle Surgery 11, no. 4 (2005): 197–201. http://dx.doi.org/10.1016/j.fas.2005.07.002.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

Krizan, K. E., D. L. Zeitler, A. U. Dogan, and S. Madison. "Correlative electron microscopic study of metallic particle contaminates in tissue adjacent to dental implants: Part I—3 months." Proceedings, annual meeting, Electron Microscopy Society of America 46 (1988): 318–19. http://dx.doi.org/10.1017/s0424820100103656.

Full text
Abstract:
The purpose of this study is to evaluate metallic contaminants in tissue surrounding tapered endodontic endosseous implants (EEI) of two different metallic implants: titanium (Ti) and vitallium (Vi, an alloy comprised of Co, Cr, Ni and Fe). These implants are used to stabilize compromised teeth. Placement followed pulpectomy and drilling to the proper depth and size for the solid implant rods which use the root canal as a pathway to supporting bone. Application of various electron microscopy techniques reveal the visual image and chemical composition of dense particles adjacent to implants as
APA, Harvard, Vancouver, ISO, and other styles
32

Fessler, H., and D. C. Fricker†. "A Study of Stresses in Alumina Universal Heads of Femoral Prostheses." Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 203, no. 1 (1989): 15–34. http://dx.doi.org/10.1243/pime_proc_1989_203_004_01.

Full text
Abstract:
Three-dimensional, frozen-stress photoelasticity was used to study the best shape for a proposed alumina universal head loaded on to a Vitallium cone taper spigot with a 30° inclined force, as in vivo. Typical cone taper friction values were reproduced in the photoelastic models. The location of the highest tensile stresses in the Mark I shape with a flat crown was found to be on the inner surface of the crown. Changing to a torispherical surface in the Mark II shape reduced this magnitude. However, the Mark III shape with a hemispherical inner crown surface gave even lower stress there, equal
APA, Harvard, Vancouver, ISO, and other styles
33

Northover, Julian R., and Mohammed Maqsood. "58-year follow-up of a vitallium mold hip arthroplasty: A case report and literature review." Acta Orthopaedica 79, no. 6 (2008): 731–33. http://dx.doi.org/10.1080/17453670810016786.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

Strumas, N., O. Antonyshyn, MJ Yaffe, G. Mawdsley, and P. Cooper. "Computed Tomography Artefacts: An Experimental Investigation of Causative Factors." Canadian Journal of Plastic Surgery 6, no. 1 (1998): 23–29. http://dx.doi.org/10.1177/229255039800600101.

Full text
Abstract:
N Strumas, O Antonyshyn, MJ Yaffe, G Mawdsley, P Cooper. Computed tomography artefacts: An experimental investigation of causative factors. Can J Plast Surg 1998;6(1):23-29. The factors that produce computed tomography (CT) artefacts associated with craniofacial fixation devices were analyzed. The effects of attenuation, motion, partial volume and implant shape were evaluated. By using a CT phantom model with an engine to produce reproducible motion, a vitallium rod, fixation plate and blank were scanned sequentially. for each experimental condition, the degree of artefact produced was quantif
APA, Harvard, Vancouver, ISO, and other styles
35

TAGUCHI, NOZOMU, Iwai TOHNAI, Fumikazu NARUSE, et al. "The correction of temporomandibular ankylosis by arthroplasty and the insertion of silicone coated cast vitallium glenoid fossa." Japanese Journal of Oral & Maxillofacial Surgery 32, no. 11 (1986): 2127–32. http://dx.doi.org/10.5794/jjoms.32.2127.

Full text
APA, Harvard, Vancouver, ISO, and other styles
36

Chapman, Cary B., Brian W. Su, Stefano M. Sinicropi, Roderick Bruno, Robert J. Strauch, and Melvin P. Rosenwasser. "Vitallium radial head prosthesis for acute and chronic elbow fractures and fracture-dislocations involving the radial head." Journal of Shoulder and Elbow Surgery 15, no. 4 (2006): 463–73. http://dx.doi.org/10.1016/j.jse.2005.09.010.

Full text
APA, Harvard, Vancouver, ISO, and other styles
37

Liu, Ming, Yaqi Hao, Lierui Zheng, Lin Niu, and Di Miao. "Role of Coke in the Passive Properties of Vitallium 2000 CoCrMo Casting Alloy in Simulated Oral Environment." Journal of Materials Engineering and Performance 28, no. 12 (2019): 7527–36. http://dx.doi.org/10.1007/s11665-019-04469-2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
38

Martinella, R., S. Giovanardi, and G. Palombarini. "Wear of ultrahigh molecular weight polyethylene sliding against surface-treated Ti6Al4V, AISI 316 stainless steel and Vitallium." Wear 133, no. 2 (1989): 267–79. http://dx.doi.org/10.1016/0043-1648(89)90041-0.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Haftbaradaran-Esfahani, Mohammadreza, Mehdi Ahmadian, and Amir Hossein Nassajpour-Esfahani. "Fabrication and characterization of porous biomedical Vitallium alloy with 58S bioglass coating prepared by sol-gel method." Applied Surface Science 506 (March 2020): 144959. http://dx.doi.org/10.1016/j.apsusc.2019.144959.

Full text
APA, Harvard, Vancouver, ISO, and other styles
40

高, 茹茹. "Application Status of Cobalt-Chromium Alloy, Pure Titanium, Vitallium 2000, and PEEK Frameworks in Removable Partial Dentures." Advances in Clinical Medicine 15, no. 03 (2025): 304–10. https://doi.org/10.12677/acm.2025.153616.

Full text
APA, Harvard, Vancouver, ISO, and other styles
41

Proussaefs, Periklis, and Jaime Lozada. "Evaluation of two Vitallium blade-form implants retrieved after 13 to 21 years of function: A clinical report." Journal of Prosthetic Dentistry 87, no. 4 (2002): 412–15. http://dx.doi.org/10.1067/mpr.2002.122960.

Full text
APA, Harvard, Vancouver, ISO, and other styles
42

Fessler, H., and D. C. Fricker†. "Friction in Femoral Prosthesis and Photoelastic Model Cone Taper Joints." Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 203, no. 1 (1989): 1–14. http://dx.doi.org/10.1243/pime_proc_1989_203_003_01.

Full text
Abstract:
Static axial push-on and lift-off, and push-on and twist-off experiments were designed and performed to measure the effective, room-temperature coefficient of friction μ for different design femoral prosthesis cone taper joints comprising a universal head on a stem spigot. Alumina and metal heads were tested on metal spigots using either distilled water, Ringer's solution, blood or no lubricant. Complementary push-on and lift-off friction tests of Araldite model joints for subsequent frozen-stress, photoelastic stress analysis were performed at 130°C. It was found that lubricant caused little
APA, Harvard, Vancouver, ISO, and other styles
43

Lim, Yi-Jia, and Beng Kuen Chan. "Short-term to medium-term outcomes of cemented Vitallium radial head prostheses after early excision for radial head fractures." Journal of Shoulder and Elbow Surgery 17, no. 2 (2008): 307–12. http://dx.doi.org/10.1016/j.jse.2007.07.020.

Full text
APA, Harvard, Vancouver, ISO, and other styles
44

Knott, Patrick T., Steven M. Mardjetko, Richard H. Kim, et al. "A comparison of magnetic and radiographic imaging artifact after using three types of metal rods: stainless steel, titanium, and vitallium." Spine Journal 10, no. 9 (2010): 789–94. http://dx.doi.org/10.1016/j.spinee.2010.06.006.

Full text
APA, Harvard, Vancouver, ISO, and other styles
45

Professor, Laila Mia Qadiri. "Investigating the properties and Usage of Cobalt." ISRG Journal of Education, Humanities and Literature (ISRGJEHL) II, no. III (2025): 47–53. https://doi.org/10.5281/zenodo.15569103.

Full text
Abstract:
<em>This essay is about a study on characteristic and uses of cobalt. The aim of this research is to find out information about characteristic and uses of cobalt. Through library research regarding to its characteristic it is found that Cobalt is a silvery-gray metal that is commonly used as an alloy with Iron and is known for its high tendency to complexes. Cobalt is found in nature in minerals such as Cobaltite CoAsS and Erythrite (Co3(AsO4)2.8H2O), This metal is hard and has little chemical activity. Its reactivity is less than that of iron, and it reacts slowly with dilute acids, releasing
APA, Harvard, Vancouver, ISO, and other styles
46

Gross, T. P., and D. W. Lennox. "Osteolytic cyst-like area associated with polyethylene and metallic debris after total knee replacement with an uncemented vitallium prosthesis. A case report." Journal of Bone & Joint Surgery 74, no. 7 (1992): 1096–101. http://dx.doi.org/10.2106/00004623-199274070-00019.

Full text
APA, Harvard, Vancouver, ISO, and other styles
47

Mareci, Daniel, Catalin Bocanu, Neculai Aelenei, and Gheorghe Nemtoi. "Galvanic Corrosion Between Ti/Ti6Al4V and Various Dental Alloys." Eurasian Chemico-Technological Journal 6, no. 3 (2017): 221. http://dx.doi.org/10.18321/ectj615.

Full text
Abstract:
&lt;p&gt;The corrosion tendencies of metals are related with their position in the electromotive series. These electrode potential degrees may change due to the composition of the alloys, the surrounding medium or due to the alterations in the composition because of the recurrent costing. The galvanic corrosion appears when different electrochemical potentials are bound to one another and the electrical conductibility is assured by the presence of an electrolyte. It is difficult to avoid coupling of different metals, a problem concerning the choice of the alloy used for the implant bone supra-
APA, Harvard, Vancouver, ISO, and other styles
48

Kotz, Rainer. "The History of Bone Tumour Treatment and the State of the Art in Vienna." PRILOZI 38, no. 3 (2017): 31–38. http://dx.doi.org/10.2478/prilozi-2018-0004.

Full text
Abstract:
Abstract Purposes:Bone tumours have been a tragedy for the patient in any time period. In the majority of the cases it occurs in children or young adults. In the past the affected limbs could not be spared and the overall prognosis was poor. Methods:Chemotherapy successfully introduced for the purpose of overcoming the poor overall prognosis (Rosen and Jaffe) and tumour prostheses were invented for the purpose of salvaging the affected limbs (Marcove, Scales, Campanacci, Sivas, Salzer). According to the Vienna Tumour Registry in 1968, the first custom-made Vitallium prosthesis for the proximal
APA, Harvard, Vancouver, ISO, and other styles
49

Krizan, K. E., D. L. Zeiller, A. U. Dogan, J. E. Laffoon, and S. Madison. "Correlative electron microscopic study of metallic particle contaminants in tissue adjacent to dental implants: Part II. 12 months." Proceedings, annual meeting, Electron Microscopy Society of America 47 (August 6, 1989): 1088–89. http://dx.doi.org/10.1017/s0424820100157425.

Full text
Abstract:
This research is a follow up of the study reported last year Part I-3 months. The purpose of this study Part II-12 months is to evaluate titanium (Ti) and vitallium (Vi, an alloy composed of Co, Cr, Ni, and Fe) endodontic endosseous implants (EEI) and the tissue surrounding them, one year after insertion. In humans this type of implant is sometimes used to stabilize compromised teeth. An adult primate model was employed using comparable techniques during implantation. Various clinical and research methodologies were used to investigate EEI and adjacent tissue in subapical bone of the maxillae
APA, Harvard, Vancouver, ISO, and other styles
50

Carvalho, Tânia Regina Vieira de, Paula Rocha Andrade, and Jonas Moraes Filho. "PESQUISA DE HEMOPARASITOS EM CARRAPATOS COLETADOS EM CÃES RESIDENTES NO MUNICIPIO DE ITU, SÃO PAULO/SP, BRASIL." Brazilian Journal of Global Health 2, no. 8 (2022): 20–22. http://dx.doi.org/10.56242/globalhealth;2022;2;8;20-22.

Full text
Abstract:
Resumo OBJETIVO: Objetivou-se nesse estudo relatar a ocorrência de Ehrlichia canis, Babesia canis vogeli e Rangelia vitalli, em carrapatos coletados em cães residentes no município de Itu_São Paulo/SP, Brasil. MÉTODOS: Foi realizada a extração de DNA de 200 amostras de carrapatos com o “kit” de extração “PureLink Genomic DNA Kit” (Invitrogen®) e realizada a PCR em tempo real para a detecção de Ehrlichia canis, Rangelia vitalli, Babesia canis vogeli. RESULTADOS: Foram testados 200 carrapatos, sendo 1/200 (0,5%) da espécie do gênero Amblyomma aureolatum e 199/200 (99,5%) de Rhipicephalus sanguin
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!