Academic literature on the topic 'Wall thermal insulation efficacy'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Wall thermal insulation efficacy.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Wall thermal insulation efficacy"

1

Deng, Jun-Xi, Xiao Li, Xiao-Juan Li, and Tai-Bing Wei. "Research on the Performance of Recycled-Straw Insulating Concrete and Optimization Design of Matching Ratio." Sustainability 15, no. 12 (2023): 9608. http://dx.doi.org/10.3390/su15129608.

Full text
Abstract:
Construction solid waste and agricultural waste, as renewable resources, have gained increasing attention recently. This research aims to explore the mechanical and thermal properties of recycled-straw insulating concrete commonly made with construction waste and straw in northern Fujian, which can provide useful suggestions for the practical use of recycled-straw insulating concrete. The effects of recycled coarse aggregate, fly ash, and straw on the mechanical and thermal properties of recycled-straw insulating concrete were investigated by orthogonal tests. The results of the orthogonal tes
APA, Harvard, Vancouver, ISO, and other styles
2

Li, Haidong, Wenjun Zhang, Yunxing Zhang, Feifei Zhai, and Fuming Chen. "Thermal bridging and its mitigation in bamboo panel construction with steel frameworks and mineral wool insulation." BioResources 19, no. 1 (2023): 416–33. http://dx.doi.org/10.15376/biores.19.1.416-433.

Full text
Abstract:
An energy-efficient and environmentally conscious bamboo-constructed residential structure was created, comprising bamboo composite panels, steel framework, and mineral wool insulation. To ascertain the efficacy of this particular type of wall in enhancing thermal capabilities, the finite element method was employed to analyze the factors influencing the thermal performance of the exterior wall panels, insulation layer, framework, and interior wall panels. A more judicious design and implementation strategy, known as the 3# and 8# combination scheme, was evaluated in practical applications to
APA, Harvard, Vancouver, ISO, and other styles
3

Chamatete, Kunda, and Çağlar Yalçınkaya. "Numerical Evaluation on Thermal Performance of 3D Printed Concrete Walls: The Effects of Lattice Type, Filament Width and Granular Filling Material." Buildings 14, no. 4 (2024): 926. http://dx.doi.org/10.3390/buildings14040926.

Full text
Abstract:
Three-dimensional concrete printing (3DCP) is of great interest to scientists and the construction industry to bring automation to structural engineering applications. However, studies on the thermal performance of three-dimensional printed concrete (3DPC) building envelopes are limited, despite their potential to provide a long-term solution to modern construction challenges. This work is a numerical study to examine the impact of infill geometry on 3DPC lattice envelope thermal performance. Three different lattice structures were modeled to have the same thickness and nearly equal contour le
APA, Harvard, Vancouver, ISO, and other styles
4

Aktemur, Cenker, and Mutlu Tarık Çakır. "Investigating the Impact of Insulation Thickness on Condensation Levels: A Case Study in Sivas, Türkiye." Black Sea Journal of Engineering and Science 8, no. 3 (2025): 883–90. https://doi.org/10.34248/bsengineering.1593337.

Full text
Abstract:
During this extensive research, an intelligent composite wall was ingeniously devised, incorporating internal and external thermal insulation to effectively handle the cold climate conditions prevalent in Sivas, Turkey. The temperature conditions of the outdoors in this region fall significantly during the night and therefore require effective thermal management solutions. The key focus of this research work is to determine the least insulation thickness that would be required to prevent surface wall condensation, which may create potential issues. The study contributes notably to identifying
APA, Harvard, Vancouver, ISO, and other styles
5

Posani, Magda, Rosário Veiga, and Vasco Peixoto de Freitas. "Retrofitting Historic Walls: Feasibility of Thermal Insulation and Suitability of Thermal Mortars." Heritage 4, no. 3 (2021): 2009–22. http://dx.doi.org/10.3390/heritage4030114.

Full text
Abstract:
The European Union is pursuing an ambitious policy on climate action, urgently calling for an acceleration in the transition toward net-zero emissions by 2050. In this context, retrofitting historic constructions can play a key role in reducing European energy consumption and consequent emissions. What is more, beyond the opportunity for tackling climate change, thermal retrofits can improve indoor comfort while lowering operational costs, factors that are fundamental to ensure the continued use of historic constructions over time, and with that, improving their preservation and durability. Th
APA, Harvard, Vancouver, ISO, and other styles
6

Zhang, Ming, Tie Wang, Xiaochuan Wang, Wentao Wu, and Jiaqi Guo. "Analysis on the laying method and thermal insulation effect of tunnel insulation layer in high-altitude cold regions." Electronic Journal of Structural Engineering 23, no. 4 (2023): 66–74. http://dx.doi.org/10.56748/ejse.23376.

Full text
Abstract:
To mitigate freeze-thaw damage in tunnels located in high-altitude cold regions, insulation layers are implemented to prevent the freezing of surrounding rocks. Currently, the selection of laying methods lacks a solid scientific basis, with the merits and demerits of various techniques remaining insufficiently evaluated. This study seeks to establish a scientifically grounded equilibrium between the anti-freezing efficacy and the construction impact of tunnel insulation in cold regions through the optimization of insulation design via numerical calculations. First, the advantages and disadvant
APA, Harvard, Vancouver, ISO, and other styles
7

Arya, Vineet Kumar, Eziaku Onyeizu Rasheed, and Don Amila Sajeevan Samarasinghe. "A Simulation-Based Study of Classroom IAQ and Thermal Comfort Performance Across New Zealand’s Six Climate Zones: The Avalon Typology." Buildings 15, no. 12 (2025): 1992. https://doi.org/10.3390/buildings15121992.

Full text
Abstract:
Indoor environmental quality profoundly impacts student learning outcomes and teacher effectiveness, particularly in primary education, where children spend most of their developmental years. The study compares the New Zealand Ministry of Education’s Designing Quality Learning Spaces (DQLS) version 2.0 for primary school classrooms with international standards set by OECD countries to develop IAQ and thermal comfort best practices in New Zealand across six climate zones. The research evaluates indoor air quality (IAQ) and thermal comfort factors affecting students’ and teachers’ health and per
APA, Harvard, Vancouver, ISO, and other styles
8

Meghna Vij. "Key Architectural Parameters for Optimizing energy efficiency of Building Envelopes: A Comprehensive Review." Tuijin Jishu/Journal of Propulsion Technology 45, no. 04 (2024): 1673–94. http://dx.doi.org/10.52783/tjjpt.v45.i04.8386.

Full text
Abstract:
Energy efficiency in building design has emerged as a pivotal concern due to escalating urbanization and its associated environmental impact. This paper critically examines the architectural parameters influencing the energy performance of building envelopes, with a specific focus on passive design strategies applicable to hospital buildings in India's composite climate. Hospitals, being high energy consumers, are key to achieving substantial energy savings through optimized building envelope design. The study explores passive techniques such as building orientation, thermal insulation, shadin
APA, Harvard, Vancouver, ISO, and other styles
9

Li, Huanyu, Guohui Feng, Yi Pu, and Han Wang. "Assessing the Application Effects and Operating Conditions on Three Different Insulation Capacity Walls Using Internal Quantitative Infrared Thermography in China." Buildings 14, no. 12 (2024): 3727. http://dx.doi.org/10.3390/buildings14123727.

Full text
Abstract:
Quantitative infrared thermography (QIRT) has emerged as a prominent topic within the field of thermal performance testing of building enclosures. The majority of the previous research has been conducted in Europe and North America, with limited research activity in Asia. Against the backdrop of China’s carbon emission reduction goals, quantitative infrared thermography offers a promising avenue for advancing building energy efficiency testing. This study conducted QIRT testing on three buildings with different insulation capabilities (old buildings, conventional insulated buildings, nearly ze
APA, Harvard, Vancouver, ISO, and other styles
10

Chen, Ximo. "Analysis of thermal characteristics and thermal storage performance of energy-saving phase change thermal storage materials in buildings." Thermal Science 28, no. 2 Part B (2024): 1509–17. http://dx.doi.org/10.2298/tsci2402509c.

Full text
Abstract:
In order to explore the thermal characteristics and thermal storage performance analysis of energy-saving phase change heat storage materials in buildings, taking the common exterior wall insulation composite wall structure in southwestern China as an example, the influence of insulation board structure thickness design on the total cost of residential air conditioning energy consumption and insulation board cost is studied, thus clarifying the concept and calculation origin of economic insulation thickness. The experimental results show that by drawing mathematical functions of energy consump
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Wall thermal insulation efficacy"

1

Wang, Hao. "Numerical study of cooling demand and thermal performance for different wall constructions." Thesis, Högskolan i Gävle, Avdelningen för bygg- energi- och miljöteknik, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-19175.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Tink, Victoria J. "The measured energy efficiency and thermal environment of a UK house retrofitted with internal wall insulation." Thesis, Loughborough University, 2018. https://dspace.lboro.ac.uk/2134/33727.

Full text
Abstract:
Approximately 30% of the UK s housing stock is comprised of older, solid wall buildings. Solid walls have no cavity and were built without insulation; therefore these buildings have high heat loss, can be uncomfortable for occupants throughout the winter and require an above-average amount of energy to heat. Solid wall buildings can be made more energy efficient by retrofitting internal wall insulation (IWI). However, there is little empirical evidence on how much energy can be saved by insulating solid wall buildings and there are concerns that internal wall insulation could lead to overheati
APA, Harvard, Vancouver, ISO, and other styles
3

Gnanachelvam, Sayilacksha. "Fire and energy performance of cold-formed steel frame wall systems." Thesis, Queensland University of Technology, 2020. https://eprints.qut.edu.au/201471/1/Sayilacksha_Gnanachelvam_Thesis.pdf.

Full text
Abstract:
This research investigated the fire and energy performance of cold-formed light-gauge steel-framed (LSF) wall configurations and proposed suitable methods to improve their combined fire and energy performance through the incorporation of (1) appropriate fire-resistive and energy-efficient building materials and (2) modifications to the arrangement or configurations of walls. This research has advanced the current knowledge of both fire and energy performance of LSF walls, paving the way for the development and use of alternative materials and LSF wall configurations.
APA, Harvard, Vancouver, ISO, and other styles
4

Berglund, Johanna, and Carolina Björkman. "Värmeisoleringsmaterial i Sverige : En jämförelse av glasull, stenull samt förnyelsebara material." Thesis, Högskolan i Gävle, Energisystem och byggnadsteknik, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-35988.

Full text
Abstract:
I Sverige ska man följa Plan- och bygglagen samt Boverkets byggregler vid ny- och ombyggnation, där både krav och regler finns för värmeisolering. Ytterväggarna är en stor del av klimatskärmen där värmeisoleringsmaterialet påverkar den värmemängd som går förlorad. Beroende på vilket värmeisoleringsmaterial man väljer, har det olika för- och nackdelar. Av denna anledning är syftet att studera olika värmeisoleringsmaterial som används i Sverige idag och hur materialen skiljer sig åt. En enkätundersökning mejlades ut till entreprenörer och återförsäljare för att ta reda på vilka värmeisoleringsma
APA, Harvard, Vancouver, ISO, and other styles
5

Niedoba, Andrzej. "Fotbalový klub." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2014. http://www.nusl.cz/ntk/nusl-226539.

Full text
Abstract:
The project designs the new building of football club with one unit on the second floor and gym that is open to the public. The building has a flat roof. It is designed as a wall construction system with a contact thermal – insulation system. The project will also include the parking and pavements.
APA, Harvard, Vancouver, ISO, and other styles
6

Tomíček, Dominik. "Zdravotní středisko." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2018. http://www.nusl.cz/ntk/nusl-372191.

Full text
Abstract:
In my diploma thesis I drafted a layout of a medical facility of emergency care in the town Kravaře. I focus on a choice of an appropriate structural design and processing of the design documentation for the construction in accordance with the laws, bylaws and the technical standard. The building is a standalone three stories building without cellar and with a flat roof. There are 16 medical units, a pharmacy and an optician. The construction is based on reinforced concrete foundation slab and walled with sand-lime blocks. The ceiling is constructed from cast-in-place reinforced slab. The faça
APA, Harvard, Vancouver, ISO, and other styles
7

Pánková, Aneta. "Mateřská školka." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2017. http://www.nusl.cz/ntk/nusl-265502.

Full text
Abstract:
This thesis solves the desing documentation for implementation of kidsgarden. The land is situated in the village Kramolna. Land is oriented to the southwest. The kidsgarden is detached as two-store building without basement. In kidsgarden there are designed three departments for children´s stay and multipurpose hall. The total projected number of children is 60. The building is founded on footings and covered with a flat roof. The building project is completed in accordance with layout, architecture and structural design and safety in use.
APA, Harvard, Vancouver, ISO, and other styles
8

Filipčík, Martin. "Polyfunkční dům." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2020. http://www.nusl.cz/ntk/nusl-409991.

Full text
Abstract:
The aim of the diploma thesis is composition of project documentation for construction of multifunctional building. Object is situated on the cadastral area of Třebíč in the location Na kopcích on the eastern part of city. Terain is slightly sloping. In the multifunctional bulding there are four above-ground floor and one below-ground floor. In the below-ground floor there are situated technical and storage spaces. In the first below-ground floor there are two entrances, the first one for administrative part and second one for residential part. The first and second above-ground floor is used f
APA, Harvard, Vancouver, ISO, and other styles
9

Juríková, Veronika. "Penzion pro seniory." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2019. http://www.nusl.cz/ntk/nusl-392230.

Full text
Abstract:
The diploma thesis deals with a new building of retirement home. This thesis aims to elaborate a project documentation for the construction of the building. It is a self-standing object on a flat land. The retirement home has one underground floor and three above ground floors. On the underground floor there are the retirement home’s technical equipment and warehouses. On the ground floor there are public services: patisserie and café, hairdresser, dining room. The first floor and the second floor are designed for the accommodation of seniors in single and double apartments. There are also a c
APA, Harvard, Vancouver, ISO, and other styles
10

Tušl, David. "Novostavba ústavu sociální péče - Bílá voda." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2018. http://www.nusl.cz/ntk/nusl-372148.

Full text
Abstract:
The subject of my master’s thesis deals with design of a new social care institution building. The building is located on land with spectacular view in Kratochvilka village. The building has four floors and basement. The building has forty beds for seniors and limited options of catering service. The building consists dining room, offices and nurse room on the first floor. Surgery, massage saloon and technical background is located in the basement. On the second, third and fourth floor are senior’s rooms. The walls will consist of bricks with an additional contact thermal insulation system ETI
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Wall thermal insulation efficacy"

1

Ridouane, El Hassan. Three-dimensional numerical evaluation of thermal performance of uninsulated wall assemblies: Preprint. National Renewable Energy Laboratory, 2011.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Ridouane, El Hassan. Thermal performance of uninsulated and partially filled wall cavities: Preprint. National Renewable Energy Laboratory, 2011.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Ignatova, Ol'ga, and Vladimir Zavadskiy. Technology of insulation and wall materials and products. INFRA-M Academic Publishing LLC., 2025. https://doi.org/10.12737/2141115.

Full text
Abstract:
The textbook provides an analysis and characteristics of various thermal, waterproofing and wall materials, an assessment of their suitability for use in construction. Classifications by structure, purpose, basic construction and operational properties, and areas of application are given. The basic schemes of manufacturing thermal insulation materials based on mineral and organic raw materials, as well as the basic principles of creating bitumen and polymer waterproofing materials are presented. Modern technologies for the production of wall products from cellular concretes, lightweight concre
APA, Harvard, Vancouver, ISO, and other styles
4

Gernot, Minke, ed. Building with earth: Design and technology of a sustainable architecture. Birkhauser-Publishers for Architecture, 2006.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Han, Byung J. Thermal Resistance of Wall Cavities Containing Reflective Insulation. Oak Ridge National Laboratory, 1988.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

Ward, Tim, Colin King, and Caroline Weeks. Reducing Thermal Bridging at Junctions When Designing and Installing Solid Wall Insulation: Fb 61. Taylor & Francis Group, 2014.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Parker, Philip M. The 2007-2012 World Outlook for Wall and Ceiling Acoustical Insulation Made from Mineral Wool for Thermal and Acoustical Envelope Insulation. ICON Group International, Inc., 2006.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

Minke, Gernot. Building with Earth: Design and Technology of a Sustainable Architecture. De Gruyter, Inc., 2012.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

Minke, Gernot. Building with Earth: Design and Technology of a Sustainable Architecture. de Gruyter GmbH, Walter, 2013.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

Minke, Gernot. Building with Earth: Design and Technology of a Sustainable Architecture. Fourth and Revised Edition. de Gruyter GmbH, Walter, 2021.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Wall thermal insulation efficacy"

1

Zhang, D. B., Z. L. Wang, H. Shi, X. Chen, and Y. H. Wang. "Application of Ground Penetrating Radar Technique in Defect Detection for External Wall Thermal Insulation System of Inorganic Thermal Insulation Mortar." In Lecture Notes in Civil Engineering. Springer Nature Singapore, 2024. http://dx.doi.org/10.1007/978-981-99-3362-4_15.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Semko, Volodymyr, Oleg Yurin, Nataliia Mahas, and Anastasiia Norka. "Insulation Thermal Conductivity (Providing Thermal Protection Norms Maintenance) Dependence on Size of a Wall Rounding Radius and an Insulation Thickness." In Lecture Notes in Civil Engineering. Springer International Publishing, 2022. http://dx.doi.org/10.1007/978-3-031-14141-6_37.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Prasittisopin, Lapyote, Kittisak Pongpaisanseree, Patiphat Jiramarootapong, and Chalermwut Snguanyat. "Thermal and Sound Insulation of Large-Scale 3D Extrusion Printing Wall Panel." In RILEM Bookseries. Springer International Publishing, 2020. http://dx.doi.org/10.1007/978-3-030-49916-7_111.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Xu, Shanshan, Ming Cao, Yunli Zhang, and Hao Jiang. "Study on thermal performance of new building energy-saving wall insulation materials." In Advances in Frontier Research on Engineering Structures Volume 1. CRC Press, 2023. http://dx.doi.org/10.1201/9781003336631-62.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Raj, Amritha, Maheshwar Kotwal, Dhanya Sathyan, and K. M. Mini. "Thermal Insulation by Fiber Added High Volume Flyash Aerated Concrete Wall Cladding." In Lecture Notes in Civil Engineering. Springer International Publishing, 2021. http://dx.doi.org/10.1007/978-3-030-80312-4_57.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

El-Gamal, S., A. Al-Kalbani, and O. Al-Hatmi. "Developing and Investigating the Performance of Thermal Insulation Lightweight Sandwich Wall Panels." In Lecture Notes in Civil Engineering. Springer Nature Singapore, 2022. http://dx.doi.org/10.1007/978-981-19-0507-0_57.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Han, Xiao, Cheng-Hsuan Yang, Yuxiang Chen, and Alejandra Hernandez Sanchez. "A Robotic Method to Insert Batt Insulation into Light-Frame Wood Wall for Panel Prefabrications." In CONVR 2023 - Proceedings of the 23rd International Conference on Construction Applications of Virtual Reality. Firenze University Press, 2023. http://dx.doi.org/10.36253/10.36253/979-12-215-0289-3.58.

Full text
Abstract:
Currently, industrial robot arms are trending in prefabricated building construction; however, a notable gap exists in established automated processes and related research specifically for the insertion of batt thermal insulation. The current method for accomplishing this task relies on manual insertion, which is labour-intensive for the workers and poses long-term health and safety concerns. This research presents an ongoing research project aimed at developing a feasible robotic process for the automated insertion of batt thermal insulation into prefabricated light-frame wood wall frames. Th
APA, Harvard, Vancouver, ISO, and other styles
8

Han, Xiao, Cheng-Hsuan Yang, Yuxiang Chen, and Alejandra Hernandez Sanchez. "A Robotic Method to Insert Batt Insulation into Light-Frame Wood Wall for Panel Prefabrications." In CONVR 2023 - Proceedings of the 23rd International Conference on Construction Applications of Virtual Reality. Firenze University Press, 2023. http://dx.doi.org/10.36253/979-12-215-0289-3.58.

Full text
Abstract:
Currently, industrial robot arms are trending in prefabricated building construction; however, a notable gap exists in established automated processes and related research specifically for the insertion of batt thermal insulation. The current method for accomplishing this task relies on manual insertion, which is labour-intensive for the workers and poses long-term health and safety concerns. This research presents an ongoing research project aimed at developing a feasible robotic process for the automated insertion of batt thermal insulation into prefabricated light-frame wood wall frames. Th
APA, Harvard, Vancouver, ISO, and other styles
9

Leonhardt, E. H. "Pressure Characteristics of Perlite Insulation in Double-Wall Tanks under Repeated Thermal Cycling." In Advances in Cryogenic Engineering. Springer US, 1995. http://dx.doi.org/10.1007/978-1-4757-0513-3_41.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Liu, Ke, Yanbin Zhang, Yi Hui, Qiang Sun, and Shoufeng Zhang. "Research on the Technology of Integrated Thermal Insulation Single-sided Composite Shear Wall." In Proceedings of the 2024 3rd International Conference on Applied Mechanics and Engineering Structures (AMES 2024). Atlantis Press International BV, 2024. http://dx.doi.org/10.2991/978-94-6463-473-0_14.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Wall thermal insulation efficacy"

1

Hock, V. F., H. Cardenas, E. Sear, and R. Knoll. "Experimental Heat Transfer Model for Optimizing Heat Exchanger Tubing." In CORROSION 1993. NACE International, 1993. https://doi.org/10.5006/c1993-93515.

Full text
Abstract:
ABSTRACT Shell-and-tube heat exchangers are frequently employed to supply domestic hot water for large buildings such as hospitals, restaurants, schools, and office complexes. An optimal heat exchanger transfers heat from the source to the target material with minimal losses to the surrounding environment. The actual amount of heat transferred varies with the heat exchanger design, the specific applications desired, the physical limits as directed by thermal efficiency, and finally, with fouling (corrosion bi-product and/or scaling). In order to combat the problems of corrosion and scale build
APA, Harvard, Vancouver, ISO, and other styles
2

Brown, Kevin J., and Kenneth A. Trimber. "Building Wall and Coating Condition Evaluation." In SSPC 2014 Greencoat. SSPC, 2014. https://doi.org/10.5006/s2014-00006.

Full text
Abstract:
Abstract The performance of coatings applied to cementitious building walls is a function of both the coating itself and the integrity of the building wall assembly. This paper addresses the tests that can be conducted to assess both the condition of the exterior coating system and the building walls, including: infrared thermal imaging; moisture testing of walls and insulation; examination of sealants, coping, scuppers, gutters, and downspouts; assessment of air infiltration and exfiltration; analysis of coating thickness, adhesion and continuity (coverage, holidays, pinholes); determination
APA, Harvard, Vancouver, ISO, and other styles
3

Singer, Marc, Nick Bardsley, Julie Morgan, et al. "Prediction of Top of Line Corrosion Risk Due to Damages in External Pipeline Insulation." In CORROSION 2021. AMPP, 2021. https://doi.org/10.5006/c2021-16789.

Full text
Abstract:
Abstract This paper presents the methodology adopted to evaluate the effect of external insulation damage on TLC within carbon steel flowlines. A field development, consisting of subsea wells in 830 m water depth, transports wet gas via two 20” diameter production flowlines. The wet gas contains about 1.5 to 2 mol% CO2. The pipeline system is largely carbon steel with only short lengths made of CRA piping. Lean MEG mixed with corrosion inhibitor is injected at the wellheads for hydrate inhibition. A subsea remotely operated vehicle inspection of the deep water 20” spools revealed insulation da
APA, Harvard, Vancouver, ISO, and other styles
4

Aylott, P. J., J. F. D. Stott, R. D. Eden, and H. K. Grover. "Monitoring of Marine Biofouling of Titanium Tubed Heat Exchanger Using a Remote Controlled Thermal Resistance Method." In CORROSION 1995. NACE International, 1995. https://doi.org/10.5006/c1995-95195.

Full text
Abstract:
Abstract A study of the marine biofouling characteristics for titanium tubed heat exchangers has been carried out using a purpose designed test rig that enabled an accurate simulation of expected service conditions. Test rigs were constructed as self-contained remote controllable units that could be moved from site to site enabling fouling data to be obtained for different seawater environments. The quantification of fouling was performed using a combination of thermal resistance measurements, biofilm sample analyses and differential pressure measurements and data were obtained giving real-tim
APA, Harvard, Vancouver, ISO, and other styles
5

Primeaux, Dudley J. "Bring on the Heat: a Novel Technique to Assess Thick-Film Thermoset Plural Component Coating Application." In Coatings+ 2019. SSPC, 2019. https://doi.org/10.5006/s2019-00042.

Full text
Abstract:
Abstract Thermal Imaging, or Infrared Thermography, is an evaluation technique that has been used in the general construction industry for many years. Often times this is used to evaluate the degree of heat loss in a structure for insulation purposes, or for detecting water leaks behind a closed wall area. Some recent cases have also shown this technique applicable for testing strength of concrete structures,. Since high solids, plural component coatings system are based upon thermoset chemistry, they often exhibit exothermic characteristics during application. The use of thermal imaging techn
APA, Harvard, Vancouver, ISO, and other styles
6

Al-Borno, Amal, Mick Brown, Xianyi Chen, and Monica Chauviere. "Identification and Testing of Potential Coatings for Use on Walls of Bag House of Flue Gas Desulfurization Process." In CORROSION 2012. NACE International, 2012. https://doi.org/10.5006/c2012-01174.

Full text
Abstract:
Abstract Flue Gas Desulfurization (FGD) results in aggressive conditions in the bag house component of the scrubbers. A test program was conducted to select a coating for corrosion protection of the internal surfaces of the bag house. Laboratory tests were developed to simulate the corrosive conditions in the bag house based on the following operating parameters: hot gas (187°F/86°C) containing water vapor and unreacted CaO, SO3 and SO2. Additionally, if the external thermal insulation is wet or inadequate, the wall temperature is cooled. If the wall temperature is below the internal process d
APA, Harvard, Vancouver, ISO, and other styles
7

Poor, Ralph P. "Vacuum Tempering at Higher Pressures." In HT 2013, edited by B. Lynn Ferguson. ASM International, 2013. https://doi.org/10.31399/asm.cp.ht2013p0289.

Full text
Abstract:
Abstract Vacuum tempering has long been recognized for ensuring part cleanliness and brightness, but recent technological advancements significantly improve processing efficiency. By increasing the operating pressure to 2 bar absolute, new vacuum furnace designs dramatically reduce heating and cooling times while maintaining the traditional benefits of vacuum-purged tempering. The process involves an initial evacuation, backfilling with an inert gas, and utilizing convection heating, with the increased gas pressure enabling higher molecular density and more rapid thermal transfer. Additional i
APA, Harvard, Vancouver, ISO, and other styles
8

Yang, Hongyan, and Dongyi Zhou. "Research on External Wall Thermal Insulation Layer Cracking Technology." In 2016 International Conference on Robots & Intelligent System (ICRIS). IEEE, 2016. http://dx.doi.org/10.1109/icris.2016.73.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Huang, C. L. "Fireproof performance study of building exterior wall thermal insulation material." In The 2015 International Conference on Electronics, Electrical Engineering and Information Science (EEEIS2015). WORLD SCIENTIFIC, 2016. http://dx.doi.org/10.1142/9789814740135_0111.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Lei Hu and Tanshu Yang. "Studies of fire prevention issues in exterior wall thermal insulation system." In 2011 Second International Conference on Mechanic Automation and Control Engineering (MACE). IEEE, 2011. http://dx.doi.org/10.1109/mace.2011.5988430.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Wall thermal insulation efficacy"

1

Meißner, Frank, Heike Sonntag, and Anita Morandell-Meißner. Water uptake measurement for thermal renovations – comparison between non-destructive method, the Karsten tube, and automatic laboratory measurements. Department of the Built Environment, 2023. http://dx.doi.org/10.54337/aau541652209.

Full text
Abstract:
The energy-efficient renovation of existing buildings requires precise knowledge of the wall structure. When using interior insulation systems, the driving rain resistance of the façade is also decisive for the function of the entire wall structure. When using interior insulation on exposed brick facades, the verification can often only be done with the help of a hygrothermal simulation. In practice, a non-destructive method, the Karsten tube or various modifications, is used to assess this essential characteristic value quickly. However, the measured values obtained from this method do not ag
APA, Harvard, Vancouver, ISO, and other styles
2

Liu, Pei, and Chiemi Iba. Influence of Energy-saving Renovation Plan on the Hygrothermal Distribution Inside Kyo-machiya Soil Walls Considering their Moisture Buffering Effect. Department of the Built Environment, 2023. http://dx.doi.org/10.54337/aau541650556.

Full text
Abstract:
Kyo-machiya are traditional townhouses in Kyoto that represent an important aspect of cultural heritage preservation. Because of the poor thermal insulation performance, they require energy-saving renovations. However, their unique soil walls possess a moisture-buffering effect that can be strongly influenced by the applied renovation plan and are expected to remain functional even after renovation. Conventional renovation methods apply an inside vapor barrier to the interior insulation to prevent condensation between the insulation and wall; however, applying this barrier may hinder the buffe
APA, Harvard, Vancouver, ISO, and other styles
3

Johra, Hicham. Project CleanTechBlock 2 Thermal conductivity measurement of cellular glass samples. Department of the Built Environment, Aalborg University, 2019. http://dx.doi.org/10.54337/aau307323438.

Full text
Abstract:
The goal of the project CleanTechBlock 2 is to develop and test a durable and sustainable construction wall element which complies with the building regulations of 2020, and has a certain aesthetics attractiveness. The CleanTechBlock (CTB) prefabricated elements consist of cellular glass insulation blocks mounted in between two layers of brick masonry [1] [2]. The aim of this technical document is to report the results of the different experimental investigations performed on the CTB and other commercial cellular glass samples to determined their thermal conductivity. These experimental invest
APA, Harvard, Vancouver, ISO, and other styles
4

Willi, Joseph, Keith Stakes, Jack Regan, and Robin Zevotek. Evaluation of Ventilation-Controlled Fires in L-Shaped Training Props. UL's Firefighter Safety Research Institute, 2016. http://dx.doi.org/10.54206/102376/mijj9867.

Full text
Abstract:
Investigations of recent firefighter line of duty deaths caused by rapid fire progression have highlighted a deficiency in firefighters’ understanding of how certain tactics affect the fire dynamics of ventilation-controlled fires. Many fires are in a ventilation-limited, decay state by the time firefighters arrive at the scene, meaning that introducing additional ventilation to the environment has the potential to cause rapid and intense fire growth. To more effectively teach firefighters about the potential effects of ventilation on a compartment fire, ventilation-controlled fires should be
APA, Harvard, Vancouver, ISO, and other styles
5

George and Hawley. PR-015-09605-R01 Extended Low Flow Range Metering. Pipeline Research Council International, Inc. (PRCI), 2010. http://dx.doi.org/10.55274/r0010728.

Full text
Abstract:
Natural gas meters are often used to measure flows below their minimum design flow rate. This can occur because of inaccurate flow projections, widely varying flow rates in the line, a lack of personnel available to change orifice plates, and other causes. The use of meters outside their design ranges can result in significant measurement errors. The objectives of this project were to examine parameters that contribute to measurement error at flow rates below 10% of a meters capacity, determine the expected range of error at these flow rates, and establish methods to reduce measurement error i
APA, Harvard, Vancouver, ISO, and other styles
6

Weinschenk, Craig, Daniel Madrzykowski, and Paul Courtney. Impact of Flashover Fire Conditions on Exposed Energized Electrical Cords and Cables. UL Firefighter Safety Research Institute, 2019. http://dx.doi.org/10.54206/102376/hdmn5904.

Full text
Abstract:
A set of experiments was conducted to expose different types of energized electrical cords for lamps, office equipment, and appliances to a developing room fire exposure. All of the cords were positioned on the floor and arranged in a manner to receive a similar thermal exposure. Six types of cords commonly used as power supply cords, extension cords, and as part of residential electrical wiring systems were chosen for the experiments. The non-metallic sheathed cables (NMB) typically found in residential electrical branch wiring were included to provide a link to previous research. The basic t
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!