To see the other types of publications on this topic, follow the link: Water pump installation.

Journal articles on the topic 'Water pump installation'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Water pump installation.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

SARTIKA, ERWANI MERRY, NOVIE THERESIA BR. PASARIBU, RUDI SARJONO, REYNALDY FELICIUS GUNAWAN, and CHRISENDY HALIM. "Pengendalian Simulator Water Supply System menggunakan PID Berdasarkan Identifikasi." ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika 10, no. 1 (2022): 213. http://dx.doi.org/10.26760/elkomika.v10i1.213.

Full text
Abstract:
ABSTRAKWater supply system dari sumber ke pengguna merupakan layanan penting, sehingga perlu dirancang untuk menyediakan air dengan tingkat tekanan yang cukup. Pengendalian water supply system dipengaruhi oleh kombinasi pemasangan pompa secara paralel dan seri untuk menghasilkan performansi yang dibutuhkan. Plant simulator water supply system dirancang dalam beberapa jenis instalasi yaitu pompa tunggal, pompa seri, pompa paralel, dan keran sebagai gangguan. Selain pengaruh instalasi, pengendalian plant simulator menggunakan PID diperlukan untuk menghasilkan tekanan air yang diinginkan. Plant s
APA, Harvard, Vancouver, ISO, and other styles
2

Mansyur, Amrullah, Muh Rusdi, and Yiyin Klistafani. "Uji Eksperimental Fenomena Water Hammer dengan Variasi Ketinggian Surge Tower." Jurnal Teknik Mesin Sinergi 21, no. 1 (2023): 105. http://dx.doi.org/10.31963/sinergi.v21i1.4226.

Full text
Abstract:
In this study an analysis of the water hammer process was carried out in a piping installation with two pumps of different specifications arranged in a single arrangement. The solution given as a form of water hammer protection is variations in the height of the surge tower in piping installations. The aim of this research is to identify the phenomenon of water hammer in piping installations with different pump discharges and the effect of the height of the surge tower as a damper against pressure fluctuations that occur. The test is carried out by closing the valve suddenly and varying the he
APA, Harvard, Vancouver, ISO, and other styles
3

Novikov, Andrey A., and Irina G. Ershova. "Experimental Installation at the Water-Ice Phase Transition." Elektrotekhnologii i elektrooborudovanie v APK 67, no. 2 (2020): 21–26. http://dx.doi.org/10.22314/2658-4859-2020-67-2-21-26.

Full text
Abstract:
The article reviewes the specifics of electricity production in Russia. One of the most effective energy saving methods is the use of heat pump installations. Its main property is the ability to extract heat from the environment: soil, water, reservoirs, the surrounding air, and the sun. Existing heat pumps with a water-ice phase transition are not efficient enough and have a high installation cost due to its complexity. (Research purpose) The research purpose is in determining the parameters and operating modes of the experimental installation at the water-ice phase transition. (Materials and
APA, Harvard, Vancouver, ISO, and other styles
4

Høeg, Arne, and Tor-Martin Tveit. "Low to very high temperature thermal energy recycling – 3 case studies." E3S Web of Conferences 313 (2021): 09001. http://dx.doi.org/10.1051/e3sconf/202131309001.

Full text
Abstract:
In this paper we present three case studies of the installation of a stirling-cycle high temperature heat pump applied to recycling thermal energy including steam generation. Many industries have heat demand at temperatures above 100°C and often the preferred energy carrier is steam. The optimal integration of a heat pump can be determined by investigating the thermal need of the process with pinch technology. For many industries, the pinch temperature is too high for conventional heat pumps. We present a heat pump solution that can recycle thermal energy and deliver this to a heat source up t
APA, Harvard, Vancouver, ISO, and other styles
5

Semenov, A., R. Kharak, Y. Bychkov, and V. Skrypnyk. "THE EFFICIENCY OF THE CONTROLLED ELECTRIC DRIVE IN WATER SUPPLY PUMP INSTALLATIONS." Slovak international scientific journal, no. 82 (April 10, 2024): 23–27. https://doi.org/10.5281/zenodo.10952901.

Full text
Abstract:
The efficiency of the controlled electric drive in pump installations for water supply systems has been studied. The impact of pump speed regulation on system productivity and reliability has been analyzed. The research results indicate a reduction in electricity consumption and optimization of pump installation operation when using a controlled electric drive, which opens up prospects for efficient resource utilization in modern water supply and drainage systems.
APA, Harvard, Vancouver, ISO, and other styles
6

Supriyono, Supriyono, Sugeng Dwi Riyanto, Muhamad Yusuf, Purwiyanto Purwiyanto, Vicky Prasetya, and Andesita Prihantara. "Penerapan Pompa Air Tenaga Surya Untuk Sarana Irigasi dan Edukasi Desa Wisata Widarapayung Wetan Cilacap." Madani : Indonesian Journal of Civil Society 6, no. 1 (2024): 26–35. http://dx.doi.org/10.35970/madani.v6i1.2026.

Full text
Abstract:
Widarapayung Wetan Village was designated as an innovation village by the Cilacap Regency Innovation Village Determination which is located in Binangun District, Cilacap Regency. The main potential of Widarapayung Wetan Village is in the tourism sector, such as Widarapayung Beach and the pioneering tourist village. The facilities that have been built and already exist in this pilot tourism village are an art performance stage, pavilion, gazebo, gamelan instruments, plantation land, and rice fields. One of the pioneering developments of tourist villages is the development of educational tourism
APA, Harvard, Vancouver, ISO, and other styles
7

Ardana, I. Gusti Ngurah, I. Ketut Suherman, I. Nyoman Sutarna, and I. Nengah Darma Susila. "Implementation of Pump Installation Simulation with Smart Relay-Based Water Level for Practical Tools in Learning Process." Logic : Jurnal Rancang Bangun dan Teknologi 19, no. 2 (2019): 91. http://dx.doi.org/10.31940/logic.v19i2.1273.

Full text
Abstract:
Polytechnic is a skill-based education with a lot of training and practice, it is necessary to be prepared practicum facilities in terms of instrumentation and control devices, especially pump installation system. An important role in the operation of a system is the electrical system in the form of control, which is useful to facilitate pump installation operation system and this piping is called the Water Level Control. The complicated difficulty is assembling electrical installations manually. This problem can be solved with water level control pump installation system based on smart relay.
APA, Harvard, Vancouver, ISO, and other styles
8

Dragomirescu, Andrei, Carmen-Anca Safta, Nicolae Orăşanu, Ioan Magheţi, and Lucian Mândrea. "Vibrations of water hydraulic systems – an experimental approach." E3S Web of Conferences 85 (2019): 06006. http://dx.doi.org/10.1051/e3sconf/20198506006.

Full text
Abstract:
This paper presents an experimental study of the vibrations induced both by cavitating and by non-cavitating flow in a hydraulic installation that comprises the main elements of a water hydraulic system. The cavitation was triggered by progressively closing a butterfly valve. The vibrations were measured on the pump, on the bearings housing, on the pump drive motor, and at nine measurement points located upstream and downstream of the main elements of the installation. The measurements were carried out at different flow rates obtained at different openings of the butterfly valve. The results s
APA, Harvard, Vancouver, ISO, and other styles
9

Wahyudi, Muhammad Prihadi Eko, Abdullah Sani, Daniel Sutopo Pamungkas, et al. "Evaluasi Penyediaan Air Bersih Dengan Sumber Listrik Tenaga Surya Untuk Fasilitas Umum Desa Pasir Panjang." Jurnal Pengabdian kepada Masyarakat Politeknik Negeri Batam 4, no. 2 (2022): 70–78. http://dx.doi.org/10.30871/abdimaspolibatam.v4i2.2836.

Full text
Abstract:
In 2018, Batam State Polytechnic has carried out community service in the village of Pasir Panjang, Rempang Island. Pasir Panjang village is one of the villages that is still not electrified by the local electricity company. The village also experiences difficulties in providing clean water because of its location on the coast. Therefore, the dedication of the Department of Electrical Engineering at the State Polytechnic of Batam in the form of grants and installation of water pumps for public facility with an independent power source from a 100WP solar cell. The problem arises when after carr
APA, Harvard, Vancouver, ISO, and other styles
10

Mathers, Harry, and Cameron Selin. "ECONOMIC ARTIFICIAL LIFT INSTALLATION IN FLOOD PRONE AREAS." APPEA Journal 32, no. 1 (1992): 398. http://dx.doi.org/10.1071/aj91031.

Full text
Abstract:
The development and exploration program in ATP 259P has evolved such that more discoveries are remote from the existing infrastructure of the Jackson Oil Field and Tickalara to Cooroo pipeline. To increase the likelihood for a commercial well completion, new ideas are being implemented, including use of a portable beam pump to test new completions, and placement of beam pumps on piles.A trailer-mounted portable beam pumping unit provides timely and cost effective data on the production characteristics of a new well, enabling more accurate designs for permanent artificial lift installations.An
APA, Harvard, Vancouver, ISO, and other styles
11

Parenden, Daniel, Peter Sahupala, and Hariyanto Hariyanto. "Utilization of Solar Energy for Water Pump Installation Design." International Journal of Heat and Technology 39, no. 3 (2021): 933–37. http://dx.doi.org/10.18280/ijht.390329.

Full text
Abstract:
In summer, the utilization of solar energy can possibly satisfy the water demand. This paper examines the fluid flow in solar pump systems with solar cells. Specifically, a solar pump system model was designed and subjected to an installation test. The model consists of two solar cell units connected in series, which generate electricity and flow into the pump system. By the principles of fluid mechanics, the test results were analyzed to optimize the pump efficiency. The analysis shows that the solar cell efficiency is influenced by solar intensity, while the pump loss is maximized by fluid f
APA, Harvard, Vancouver, ISO, and other styles
12

Bublikov, A., K. Sosnin, and Yu Papaika. "Automatic control of the coal mining drainage installation taking into account the trison tariff for electricity." Collection of Research Papers of the National Mining University 64 (2021): 239–52. http://dx.doi.org/10.33271/crpnmu/64.239.

Full text
Abstract:
Objective is to reduce the specific energy consumption for dewatering in coal mines by minimizing time intervals of the switched-on pumps during the peak load hours when the electric energy cost reaches its maximum. Research methodology. Simulation modelling of water pumping from a water intake facility at a mining enterprise has been used to study automotive control of a water-removal plant. In this context, simulation of the whole system of automatic control is performed involving the proposed algorithm of pump switching on/off in terms of the criteria of entering the peak load hours accordi
APA, Harvard, Vancouver, ISO, and other styles
13

Гонтарев, С., S. Gontarev, Сергей Мошаров, Sergey Mosharov, М. Корсак, and M. Korsak. "Novel Way for Continuous Filtration of Large Volumes of Water in Environmental Monitoring System." Safety in Technosphere 6, no. 3 (2017): 13–17. http://dx.doi.org/10.12737/article_59d3a1993a6f61.46420059.

Full text
Abstract:
During ecological researches and monitoring of the natural aquatic environment it is very often necessary to carry out filtration of water large volumes for extraction on filters the weighed components, and for subsequent analysis of mineral and organic suspension’s structure. The installations applied now for vacuum filtration have a number of essential restrictions. The most important deficiency of existing installations for vacuum filtration is the use of a leak-tight receiver with rigid design. At intensive filtration such receiver has to have a large volume that limits filtration installa
APA, Harvard, Vancouver, ISO, and other styles
14

Wibolo, Achmad, I. Ketut Suherman, I. Dewa Made Pancarana, and I. Ketut Adi. "Analysis of the Selection and Installation of a Pump for an Overflow Swimming Pool with a Volume of 67 Cubic Meters." LOGIC : Jurnal Rancang Bangun dan Teknologi 23, no. 2 (2023): 138–46. http://dx.doi.org/10.31940/logic.v23i2.138-146.

Full text
Abstract:
In the swimming pool there is a pump system that is useful for circulating water. Pumps in swimming pools can affect water quality. Dirty water will be cleaned by the filter and will be re-circulated to the swimming pool. The calculations that must be known are the volume of the swimming pool, pump power, flow rate, and the curve of the pump. In order for the selection of a swimming pool pump to be appropriate, the correct calculation must be made so that the pump can provide the best performance for a swimming pool with a volume of 67 cubic meters and is able to circulate swimming pool water
APA, Harvard, Vancouver, ISO, and other styles
15

Liu, Hao, Hongyi Zhang, and Saqib Javed. "Long-Term Performance Measurement and Analysis of a Small-Scale Ground Source Heat Pump System." Energies 13, no. 17 (2020): 4527. http://dx.doi.org/10.3390/en13174527.

Full text
Abstract:
Recent data suggest that heat pumps, despite having the potential to cover over 90% of the global space and water heating demands, only provide less than 5% of global heating. Heat pumps, in general, and ground source heat pumps, specifically, offer significant potential for energy savings and carbon emissions reduction in buildings. The realization of these potential benefits, however, requires proper design, installation, and operation of the entire heat pump system. This paper presents the performance analysis of a Swedish ground source heat pump system providing space heating and hot water
APA, Harvard, Vancouver, ISO, and other styles
16

V. P. Markovskiy, S. D. Pushkaryov, A. I. Ogarkova, A. B. Utegulov, and I. V. Koshkin. "DEVELOPMENT OF A CONJUGATE ANALYSIS METHOD FOR THE EFFECTIVE USE OF HEAT PUMPS IN THE CLIMATIC CONDITIONS OF KOSTANAY REGION." Bulletin of Toraighyrov University. Energetics series, no. 2.2024 (June 28, 2024): 225–42. http://dx.doi.org/10.48081/qgdw8672.

Full text
Abstract:
The article discusses the issues of effective use of heat pumps in the northern region of Kazakhstan, Kostanay region. The purpose of this article is to study the physical and technological characteristics of various types of refrigerants for the effective use of heat pumps in the climatic conditions of Northern Kazakhstan, using the «Water – Water» coolant system, taking into account the external and internal parameters of the system’s interaction. An analysis of the estimated climatic and soil characteristics of the Kostanay region was carried out, and priority methods for designing heat pum
APA, Harvard, Vancouver, ISO, and other styles
17

Zhang, Bowen, Li Cheng, Chunlei Xu, and Mo Wang. "The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station." Energies 14, no. 4 (2021): 1039. http://dx.doi.org/10.3390/en14041039.

Full text
Abstract:
A prefabricated pumping station is a new type of pumping station that plays an important role in the construction of sponge cities in developing countries. It solves the problem of urban water-logging and makes great contributions to the sustainable development of water resources. In order to research the influence of different installation positions of pumps on the internal hydraulic performance of a prefabricated pumping station, based on ANSYS software, the computational fluid dynamics (CFD) numerical simulation method was used to analyze the internal flow state of the prefabricated pump st
APA, Harvard, Vancouver, ISO, and other styles
18

Prof. Praveen Rathod, Shreerang Karambelkar, Rutvik Khaire, Mangesh Dhavale, and Pruthviraj Raut. "Automated Water Pump System." international journal of engineering technology and management sciences 7, no. 3 (2023): 247–55. http://dx.doi.org/10.46647/ijetms.2023.v07i03.032.

Full text
Abstract:
Automated water pump systems are becoming increasingly important as they can regulate water pumps based on current data and conditions, reducing energy use and water waste while ensuring efficient water distribution. Research shows that automated water pump systems have several advantages over traditional manual systems, including increased efficiency, lower energy consumption, better water management, and improved pump performance. However, there are also some drawbacks to using these systems, such as higher upfront costs due to advanced equipment and technology requirements, complex installa
APA, Harvard, Vancouver, ISO, and other styles
19

Awari, G. K., P. M. Ardhapurkar, D. G. Wakde, and L. B. Bhuyar. "Performance analysis of air-lift pump design." Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science 218, no. 10 (2004): 1155–61. http://dx.doi.org/10.1243/0954406042369099.

Full text
Abstract:
The air-lift pump is a well-established method for vertical transport of liquids and solid-liquid mixtures. The objectives of the present study are to evaluate the performance of a pump under predetermined operating conditions and to optimize the related parameters for the use of the pump for two-phase mixtures of air and water when a compressor is readily available. This paper is focused on the general mathematical functions applicable to air-lift pump installations. The effect of various design parameters on the performance of air-lift pump is presented. A user-friendly computer program is d
APA, Harvard, Vancouver, ISO, and other styles
20

Sudirman, Sudirman, and Hasan Basri. "Training of simple fire installation for security guard at Samarinda State Polytechnic." Community Empowerment 6, no. 12 (2021): 2172–75. http://dx.doi.org/10.31603/ce.6463.

Full text
Abstract:
The Samarinda State Polytechnic has a hydrant that does not work, because the installation is damaged and is 35 years old. Currently, a simple fire fighting water installation has been made at three points with a length of 257 meters for 16 buildings, which utilizes lake water inside the Samarinda State Polytechnic campus. Therefore, this service activity is intended to provide skills for security guard in the Samarinda State Polytechnic regarding the use of hydrants. The specifications of the equipment used are portable centrifugal pumps with a maximum capacity of 700 liters/minute, a horizon
APA, Harvard, Vancouver, ISO, and other styles
21

Yasa, I. Made Sumerta, I. Gusti Ngurah Agung Dwijaya Saputra, Ketut Vini Elfarosa, Anak Agung Putri Indrayanti, Ida Bagus Ketut Sugirianta, and Agus Adi Putrawan. "PLTS Utilization of Solar Power for Irrigation of "Nyayur"." Jurnal Pengabdian Masyarakat 5, no. 1 (2024): 136–43. http://dx.doi.org/10.32815/jpm.v5i1.1364.

Full text
Abstract:
Purpose: Around 10 hectares of rice fields, including nyayur land, in Subak Sembung Peguyangan, North Denpasar, Bali, do not receive water, especially in the dry season, due to the location of the land being higher than the main irrigation canal. For this reason, it is necessary to create water irrigation by installing a 125W/220V water pump with an electricity supply from solar power. Method: The stages of implementing the service are carried out with the stages of socialization, installation and testing of tools/systems, training and maintenance of tools/systems. Practical Applications: With
APA, Harvard, Vancouver, ISO, and other styles
22

Faccio, Maurizio, Mauro Gamberi, Mojtaba Nedaei, and Francesco Pilati. "Technical and economic modelling and evaluation of a water distribution system equipped with an autoclave for industrial production applications." Journal of Engineering, Design and Technology 16, no. 3 (2018): 342–59. http://dx.doi.org/10.1108/jedt-05-2017-0043.

Full text
Abstract:
Purpose The purpose of this paper is to investigate the autoclave-pump pressured water distribution system. Pressured water is used in many manufacturing processes, as a raw material or as a service fluid for different applications. Design/methodology/approach The performances and the total installation costs of such systems are strongly related to its design and to its decision variables definition. The authors first identify the independent variables (i.e. the decision variables) and the dependent variables of the system and, second, propose a techno-economic mathematical method able to dete
APA, Harvard, Vancouver, ISO, and other styles
23

Wang, Xingtao, Jian Zhang, Xiaodong Yu, and Lin Shi. "Research on the water hammer protection of the air vessel caused by underground pipe burst in long distance water supply system." MATEC Web of Conferences 246 (2018): 01066. http://dx.doi.org/10.1051/matecconf/201824601066.

Full text
Abstract:
The conventional air vessel installation is usually installed behind the check valve at the upstream end of the pipeline to effectively control the water hammer pressure due to pump trip. However, the water hammer pressure caused by underground pipe burst has been neglected. The water hammer protection of air vessel due to pipe burst in long distance water supply system was discussed in this paper. According to analysis of the process of the pipe burst, the mathematical model of underground pipe burst and air vessel were established. A new air vessel installation that was installed in the midd
APA, Harvard, Vancouver, ISO, and other styles
24

Ivashechkin, V. V., V. I. Krytskaya, V. N. Anufriev, and O. A. Avrutin. "Methodology for Analyzing the Actual Technical Condition of Downhole Pumping Equipment." ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations 64, no. 3 (2021): 275–86. http://dx.doi.org/10.21122/1029-7448-2021-64-3-275-286.

Full text
Abstract:
The reducing in the pressure characteristic of the submersible pump during operation occurs as a result of the combined action of a number of reasons. Pumping equipment wears out due to waterjet destruction of flow channels. The characteristics of submersible pumps are captured at the factory on special stands. At large group groundwater intakes, wells are equipped with an automated control system that allows testing the pump at the workplace and promptly making a decision on its replacement if the pressure characteristic is unacceptably reduced. The actual pressure characteristic of the pump
APA, Harvard, Vancouver, ISO, and other styles
25

Pasaribu, Gardin karnen Osmal. "Transfer Pump Selection for Oyama Hotel." Saudi Journal of Engineering and Technology 7, no. 7 (2022): 392–98. http://dx.doi.org/10.36348/sjet.2022.v07i07.007.

Full text
Abstract:
Transfer Pump Selection for Oyama Hotel. The calculation and selection of the transfer pump has been carried out in the clean water installation of the Oyama hotel building. Transfer pump is required to move (lift) clean water from the ground water tank to the roof tank. The pump selection method is based on calculation of pump capacity and head. Pump capacity calculation is based on water demand during peak hours. Pump head calculation is based on static head and friction loss in the piping. From the results of the calculations, the capacity is 20m3/hour and the pump head is 9 bars.
APA, Harvard, Vancouver, ISO, and other styles
26

Hamdani*, Hamdani, Dwiprima Elvanny Myori, and Ali Basrah Pulungan Pulungan. "Public education via the implementation of alternative energy sources in solar water pump." Dinamisia : Jurnal Pengabdian Kepada Masyarakat 8, no. 1 (2024): 104–13. https://doi.org/10.31849/dinamisia.v8i1.16873.

Full text
Abstract:
This dedication is underpinned by public insight, and manager Mushalla Darul Ittihad's opinion about alternative energy still needs to be improved. The imbalance between the available electricity and the electricity load used often disrupts electricity due to overload. Interfere with the smoothness of worship activities. Besides lighting and sound amplifiers, the biggest electric charge lies on the water pumps that live all day. Therefore, additional power sources not charging the mushalla's operating costs are needed to cope with the problem. This activity aims to educate participants and off
APA, Harvard, Vancouver, ISO, and other styles
27

Hua, Ertian, Yabo Song, Caiju Lu, Mingwang Xiang, Tao Wang, and Qizong Sun. "Numerical Study on the Influence of Installation Height and Operating Frequency of Biomimetic Pumps on the Incipient Motion of Riverbed Sediment." Water 16, no. 13 (2024): 1925. http://dx.doi.org/10.3390/w16131925.

Full text
Abstract:
Biomimetic pumps can effectively enhance the hydrodynamics of plain river networks, improve the water environment, and facilitate the transport of sticky bottom sediment. In this paper, a biomimetic pump equipped with an NACA0012 wing profile was used as the research subject, and a commercial CFD package was employed to investigate the impact of the pump’s installation height (the vertical distance from the hydrofoil’s pivot to the riverbed) and operating frequency on the incipient motion of riverbed sediment. The results indicate that the lowest maximum near-bed velocity is obtained at an ins
APA, Harvard, Vancouver, ISO, and other styles
28

Marchi, A., A. R. Simpson, and N. Ertugrul. "Assessing variable speed pump efficiency in water distribution systems." Drinking Water Engineering and Science 5, no. 1 (2012): 15–21. http://dx.doi.org/10.5194/dwes-5-15-2012.

Full text
Abstract:
Abstract. Energy savings and greenhouse gas emission reductions are increasingly becoming important design targets in many industrial systems where fossil fuel based electrical energy is heavily utilised. In water distribution systems (WDSs) a significant portion of operational cost is related to pumping. Recent studies have considered variable speed pumps (VSPs) which aim to vary the operating point of the pump to match demand to pumping rate. Depending on the system characteristics, this approach can lead to considerable savings in operational costs. In particular, cost reductions can take a
APA, Harvard, Vancouver, ISO, and other styles
29

Marchi, A., A. R. Simpson, and N. Ertugrul. "Assessing variable speed pump efficiency in water distribution systems." Drinking Water Engineering and Science Discussions 5, no. 1 (2012): 47–65. http://dx.doi.org/10.5194/dwesd-5-47-2012.

Full text
Abstract:
Abstract. Energy savings and greenhouse gas emission reductions are increasingly becoming important design targets in many industrial systems where fossil fuel based electrical energy is heavily utilised. In water distribution systems (WDSs) a significant portion of operational cost is related to pumping. Recent studies have considered variable speed pumps (VSPs) which aim to vary the operating point of the pump to match demand to pumping rate. Depending on the system characteristics, this approach can lead to considerable savings in operational costs. In particular, cost reductions can take a
APA, Harvard, Vancouver, ISO, and other styles
30

Monangin, Galvani Amideo, Novi Dwi Raharjo, Ahmad Ahmad, and Eddy Setiadi Soedjono. "North Banjarmasin’s distribution pump’s electric energy audit at PT Air Minum Bandarmasih." Indonesian Journal of Multidisciplinary Science 3, no. 2 (2023): 110–14. http://dx.doi.org/10.55324/ijoms.v3i2.715.

Full text
Abstract:
This study aims to audit the electrical energy of the North Banjarmasin zone distribution pump at the Bandarmasih Drinking Water Company in Banjarmasin City. The case study method was used to find out the description of the problem conditions of the pump installation system and the existing distribution network. The largest electricity consumption is in the operation of distribution pumps. One of the distribution pumps is the Banua Anyar booster pump which serves the North Banjarmasin zone. Electricity consumption during 2022 on the Banua Anyar booster is 1,223,432 kWh at a cost of Rp. 1,521,7
APA, Harvard, Vancouver, ISO, and other styles
31

Oliinyk, Halyna. "Study of the efficiency of using a heat pump in the heat supply system of a private house." Scientific journal of the Ternopil national technical university 107, no. 3 (2022): 14–20. http://dx.doi.org/10.33108/visnyk_tntu2022.03.014.

Full text
Abstract:
Currently, air-to-water heat pumps are in high demand, which, thanks to the high coefficient of heat conversion, reduce energy consumption and negative impact on the environment. The advantages of using a heat pump are safety, environmental friendliness, economy, and the fact that when using it, dependence on rising prices for natural energy sources is reduced. One of the main problems of the air-to-water heat pump is a decrease in productivity when the outside air temperature drops in winter. This paper analyzed the efficiency of air-to-water heat pump Mitsubishi Electric PUHZ-SHW230YKAR1 for
APA, Harvard, Vancouver, ISO, and other styles
32

Martin-Candilejo, Araceli, David Santillán, and Luis Garrote. "Pump Efficiency Analysis for Proper Energy Assessment in Optimization of Water Supply Systems." Water 12, no. 1 (2019): 132. http://dx.doi.org/10.3390/w12010132.

Full text
Abstract:
Water supply systems need to be designed accounting for both construction and operational costs. When the installation requires water pumping, it is key for the operational costs to know how well the pump can perform. So far, pump efficiency has been considered using conservative values, in the absence of a better estimation. The aim of this paper was to improve determining the energy costs by clarifying what the value of the pump performance should be. For this, 226 commercial pumps were studied, registering the efficiency at the optimum operating point, as well as other variables such as the
APA, Harvard, Vancouver, ISO, and other styles
33

FINYK, Iryna. "FEATURES OF THE USE OF HEAT PUMPS IN THE HEATING SYSTEMS OF PRIVATE HOUSES." Herald of Khmelnytskyi National University. Technical sciences 311, no. 4 (2022): 14–17. http://dx.doi.org/10.31891/2307-5732-2022-311-4-14-17.

Full text
Abstract:
In the paper, it is investigated that economics is the main advantage of thermal pumps. The financial costs during the heating season are almost three times lower than natural gas. You do not need any permissions to connect. The operation of heat pump units is absolutely safe and environmentally friendly. Since ancient times, heat pump units have been used as alternative heating systems. Such systems are reliable, have a long term of operation and are the most environmentally friendly. Heat pump units are seen as a new step toward the development of more efficient and safer systems. The main h
APA, Harvard, Vancouver, ISO, and other styles
34

Song, Xijie, Kuizheng Zhu, and Zhengwei Wang. "Research on the Influence of Symmetrical Installation of Blade on the Sediment Erosion in a Multi-Stage Centrifugal Pump." Symmetry 16, no. 12 (2024): 1636. https://doi.org/10.3390/sym16121636.

Full text
Abstract:
Double suction pumps are widely used in the Yellow River in the China water intake pump stations, which face serious sediment wear. A prediction model for gap erosion in gas-liquid solid three-phase flow was constructed. A gas core factor has been added to the gap erosion model to achieve accurate prediction of particle impact velocity and impact angle caused by cavitation air core deformation. The influence mechanism of cavitation flow and sand-laden suction vortex on the sediment erosion. Usually, double suction pumps are one type. This study aims to explore the effects of the symmetrical an
APA, Harvard, Vancouver, ISO, and other styles
35

Di Schio, Eugenia Rossi, Vincenzo Ballerini, and Paolo Valdiserri. "The Bin Method to Investigate the Effect of Climate Conditions on the SCOP of Air Source Heat Pumps: the Italian Case." WSEAS TRANSACTIONS ON HEAT AND MASS TRANSFER 17 (May 7, 2022): 124–30. http://dx.doi.org/10.37394/232012.2022.17.13.

Full text
Abstract:
The paper investigates the seasonal performances of electric air-to-water heat pumps specifically related to climatic conditions of the place where the heat pump is installed. The analysis is carried out using easily available weather data for some Italian towns differently located, and using the bin-method proposed by UNI/TS 11300-4. Two different types of heat pumps (on-off and inverter-driven variable speed compressor) are considered and comparisons between different types of heat pumps and different places of installation are performed. The analysis shows that the climate of the installati
APA, Harvard, Vancouver, ISO, and other styles
36

Treshcheva, Milana, Dmitriy Treshchev, and Daria Pozdeeva. "Applying heat pumps to utilize municipal solid waste at St. Petersburg TPP." E3S Web of Conferences 140 (2019): 04002. http://dx.doi.org/10.1051/e3sconf/201914004002.

Full text
Abstract:
In this article, we address an urgent problem of solid waste management. We consider the possibility of applying gasification technology for municipal solid waste disposal at existing TPPs in St. Petersburg in order to produce thermal and electric energy. St. Petersburg Northern TPP-21, facing the problem of undercooling of the circulating water in the cooling towers, is proposed as a possible placement site. Using this water as a source of low-grade heat of a heat pump installation is considered as the possible solution to the problem. The study was carried out by calculating the thermal circ
APA, Harvard, Vancouver, ISO, and other styles
37

Jiao, Weixuan, Zhishuang Li, Li Cheng, Yuqi Wang, and Bowen Zhang. "Study on the Hydraulic and Energy Loss Characteristics of the Agricultural Pumping Station Caused by Hydraulic Structures." Agriculture 12, no. 11 (2022): 1770. http://dx.doi.org/10.3390/agriculture12111770.

Full text
Abstract:
The pumping station is an important part of the agricultural irrigation and drainage system. The sump is one of the common water inlet types of agricultural pumping stations. In the sump, to facilitate the installation and maintenance of equipment, some hydraulic structures, such as pump beams, maintenance platforms and chest walls, are added to the sump. At present, the impact of hydraulic structures in the sump on the hydraulic performance of the pump device is not clear, so this paper focused on the impact of hydraulic structures on the hydraulic characteristics and entropy generation chara
APA, Harvard, Vancouver, ISO, and other styles
38

Shin, Ji-Hyun, Yong-In Kim, and Young-Hum Cho. "Development of Operating Method of Multi-Geothermal Heat Pump Systems Using Variable Water Flow Rate Control and a COP Prediction Model Based on ANN." Energies 12, no. 20 (2019): 3894. http://dx.doi.org/10.3390/en12203894.

Full text
Abstract:
As the global energy trend continues, the importance of energy savings and efficient use is being emphasized, and the installation and operation of geothermal heat pump systems is increasing. In many buildings, where an actual geothermal heat pump system has been installed, problems of efficiency deterioration occur frequently because of the inefficient operation after installation of the heat pump system. The purpose of this study was to develop and verify the operating method for energy saving and performance improvement of multiple geothermal systems. A coefficient of performance (COP) pred
APA, Harvard, Vancouver, ISO, and other styles
39

Sudirman. "Major and Minor Head Losses Analysis on The Piping System in Pondok Pesantren Tahfizhul Qur'an Ibnu Abbas Tarakan." BEST : Journal of Applied Electrical, Science, & Technology 3, no. 1 (2021): 11–16. http://dx.doi.org/10.36456/best.vol3.no1.3535.

Full text
Abstract:
The head loss analysis in this study is focused on the existing piping system at the Ibnu Abbas Tarakan Tahfizhul Qur'an Islamic Boarding School, so that it is known that the flow losses that occur are both major losses and minor losses. The stages taken are; literature review by reviewing several previous studies then continued with data collection on the piping system in Ibnu Abbas Tarakan Islamic Boarding School. The discussion of head losses in the piping system is divided into four parts according to the existing branching of the pipe installation when the water comes out of the pump. Hea
APA, Harvard, Vancouver, ISO, and other styles
40

TRUNOV, S. S. "SUBSTANTIATION OF AN ENERGY-SAVING FUNCTIONAL DIAGRAM OF THE HEAT STORAGE UNIT FOR HEATING WATER ON CATTLE FARMS." Elektrotekhnologii i elektrooborudovanie v APK 71 (2024): 68–75. http://dx.doi.org/10.22314/2658-4859-2024-71-3-68-75.

Full text
Abstract:
Analysis of electric energy consumption on cattle farms has shown that hot water supply is one of the energy-intensive technological processes on such farms. In order to save energy resources when heating water, a functional scheme of an accumulator installation has been developed that allows heating water for watering cows and providing technological needs. The standard water temperature for drinking is 12-15 degrees Celsius, for technological needs - 55-65 degrees Celsius. (Research purpose) The research purpose is substantiating and developing a functional scheme of an energy-saving install
APA, Harvard, Vancouver, ISO, and other styles
41

Hong-wen, Jin, Yang Lei, Song Bing-qi, Wu Yong-liang, and Zhang Yan-peng. "Study on the influence factors of energy efficiency ratio of low temperature air source heat pump." E3S Web of Conferences 165 (2020): 01030. http://dx.doi.org/10.1051/e3sconf/202016501030.

Full text
Abstract:
In this paper, through the experimental study of two heating seasons, it is found that the heat pump installation position and orientation, circulating pump work/frequency conversion, frosting conditions, etc. have a greater impact on the heat pump unit energy efficiency ratio. According to the actual operation data and theoretical derivation, the analysis shows that the energy efficiency ratio increases by 2.4% when the installation position and orientation increase the air temperature by 1K. The circulating water pump can save 78% of the power consumption in the period by changing the power
APA, Harvard, Vancouver, ISO, and other styles
42

Rzeźnik, Ilona. "Investigation of temperature drop in domestic hot water circuit." E3S Web of Conferences 44 (2018): 00158. http://dx.doi.org/10.1051/e3sconf/20184400158.

Full text
Abstract:
The results of experimental investigation of determining the time of temperature drop in domestic hot water circuit were presented in this paper on the example of single-family house. The test were carried out on vertical sections of installations made of PE-X/Al/PE pipes (cross-linked polyethylene and aluminum) with and without insulation. The temperature drop process was investigated in temperature range typical for domestic hot water installation from 55ºC to 40ºC. On the basis of the obtained results with appropriate adjustment of the working time of circulation pump, energy savings of 90%
APA, Harvard, Vancouver, ISO, and other styles
43

Kondus, Vladyslav, Ivan Pavlenko, Oleksandr Kulikov, and Oleksandr Liaposhchenko. "Development of a High-Rotational Submersible Pump for Water Supply." Water 15, no. 20 (2023): 3609. http://dx.doi.org/10.3390/w15203609.

Full text
Abstract:
Submersible pumps are the leading electricity consumers in centralized water supply systems. Considering the cost structure of the life cycle of pumping equipment, the main costs should include investment costs, electricity costs during operation, and costs of repairing pumping equipment. Considering the growing cost of electricity in the world, the cost of manufacturing pumping equipment is significantly increasing, which in turn causes an increase in its price. The key factor in increasing the competitiveness of such equipment on the market is its modernization with the achievement of a high
APA, Harvard, Vancouver, ISO, and other styles
44

Mustofa, W. A., and P. H. Tjahjanti. "Impact of Pipe Length on Discharge and Headloss in PVC Water Pipe Installations." IOP Conference Series: Earth and Environmental Science 1242, no. 1 (2023): 012019. http://dx.doi.org/10.1088/1755-1315/1242/1/012019.

Full text
Abstract:
Abstract This study was conducted to investigate the implications of pipe length on water discharge and headloss in clean water pipe installations in Klampok hamlet, Indonesia. Three residential houses were selected as research sites, each equipped with a 2-inch diameter PVC type pipe and a water pump with a power of 3.6 housepower. The goal was to measure the water discharge, major and minor headloss, and the flow pattern within these pipe installations. Results revealed a water pump discharge to the reservoir of 0.004 m3/s, while the reservoir water discharge designated to supply residents’
APA, Harvard, Vancouver, ISO, and other styles
45

Klendiy, P., L. Kolodiychuk, and O. Dudar. "Energy efficient water pumping installation on the basis of frequency-regulated electric drive." Energy and automation, no. 2(54) (June 22, 2021): 81–96. http://dx.doi.org/10.31548/energiya2021.02.081.

Full text
Abstract:
Electric pumping units are not characterized by optimal operating modes and today are energy-intensive technologies. Water consumption is determined by unevenness and is formed under the influence of many, often uncontrollable factors. The inconsistency of the planned water supply regime with the actual water consumption leads to excessive pressures, which causes not only direct overconsumption of electricity at pumping stations, but also increases the likelihood of accidents in the network, contributes to greater water losses due to leaks in the water supply network. additional overconsumptio
APA, Harvard, Vancouver, ISO, and other styles
46

mohamd, Ibrahim Salim masoud, Abuladeem Basher Alrabee, Rashid H. Abugoffa, Ayat Abdulmajid Almabruk, and Hannah Hamed Abozaid. "Troubleshooting Techniques for Electric Submersible Pumps (ESPs)." International Science and Technology Journal 36, no. 1 (2025): 1–22. https://doi.org/10.62341/iarh1943.

Full text
Abstract:
Electric Submersible Pumps (ESPs) are a widely preferred solution for artificial lift, particularly in high water-cut wells. This study investigates troubleshooting and optimization techniques for ESP installations, with a focus on the applications of Advanced Gas Handlers (AGH) and Variable Speed Drives (VSD). It examines two case studies: the Waha field equipped with an AGH and the Sarir field employing an oversized pump. The primary objectives include leveraging AGH capabilities to reduce tubing costs and enhance production rates, as well as optimizing oversized pump performance while evalu
APA, Harvard, Vancouver, ISO, and other styles
47

Gumilang, Reno Reza, and Citra Indah Asmarawati. "ANALISIS HEADLOSS PADA JARINGAN PERPIPAAN DISTRIBUSI AIR BERSIH DI PERKEBUNAN MARINA KOTA BATAM." Computer and Science Industrial Engineering (COMASIE) 8, no. 1 (2023): 77–85. http://dx.doi.org/10.33884/comasiejournal.v8i1.6678.

Full text
Abstract:
The rapid population growth will be directly proportional to the need for clean water, so that sooner or later various problems will arise in fulfilling the need for clean water. Marina Plantation, which is located in the city of Batam, is an area where the majority of the population work as gardeners and breeders. The increase in population and the expansion of the plantation area have resulted in a decrease in the burden on the clean water network. In this study the method used is a quantitative method using the Darcy Weisbach calculation formula with the help of Excel software to simplify c
APA, Harvard, Vancouver, ISO, and other styles
48

Murano, Giovanni, Francesca Caffari, Nicolandrea Calabrese, and Marco Dall’Ombra. "Meeting 2030 Targets: Heat Pump Installation Scenarios in Italy." Sustainability 17, no. 13 (2025): 5938. https://doi.org/10.3390/su17135938.

Full text
Abstract:
The study examines the role of heat pumps (HPs) in achieving the targets set by the Italian National Integrated Energy and Climate Plan (PNIEC) for 2030, using official data and European-recognized calculation methodologies to quantify the renewable energy produced. Starting from the current stock analysis—21 million HPs installed in 2022, providing 39 GWth of thermal capacity—the research outlines potential growth scenarios based on installation trends from the past three years: Scenario A assumes 2.5 million HPs/year, (b) 2.2 million/year, and (c) 1.6 million/year. Only Scenario A, the most
APA, Harvard, Vancouver, ISO, and other styles
49

Abdreshov, Sh A., I. S. Seitasanov, A. A. Yakovlev, Ye S. Sarkynov, and B. A. Zulpykharov. "FEASIBILITY STUDY COMPLETED DEVELOPMENT OF THE WATER-JET PUMP INSTALLATION." Вестник Алматинского университета энергетики и связи, no. 4 (2019): 82–87. http://dx.doi.org/10.51775/1999-9801_2019_47_4_82.

Full text
APA, Harvard, Vancouver, ISO, and other styles
50

Velasco, F. J. S., J. Giménez-Villa, J. R. García-Cascales, F. Illán-Gómez, J. P. Delgado Marín, and R. A. Otón-Martínez. "Comparative analysis of the behaviour of the hot water production system of an indoor swimming pool." Journal of Physics: Conference Series 2766, no. 1 (2024): 012110. http://dx.doi.org/10.1088/1742-6596/2766/1/012110.

Full text
Abstract:
Abstract In this paper, we analyse the thermal behaviour and the environmental impact of an indoor swimming pool placed in Pozo Estrecho, Cartagena, in the Southeast of Spain. The existing installation is formed by a group of solar thermal collectors supported by two propane heaters which heat the water of the pool and satisfy the needs of hot water in the changing room of the pool. Here we propose an installation based on the use of a heat pump supported by solar thermal collectors. In this work, we first describe the installations. They are modelled with Trnsys and the models employed briefl
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!