Dissertations / Theses on the topic 'Water - Purification - Dissolved air flotation'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 30 dissertations / theses for your research on the topic 'Water - Purification - Dissolved air flotation.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Löf, Ludwig. "Evaluation of Dissolved Air Flotation for Water Purification: With Focus on Floc Characteristics and PFAS." Thesis, KTH, Kemiteknik, 2021. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-298378.
Full textIn this project, attempts have been made to collect data that allows the municipal association Norrvatten in the decision-making process on the flotation/ sedimentation step of their water treatment process. In this sense, poly- and perfluorinated alkyl substances (PFAS) concentration and the characteristics of agglomerated particles (flocs) have been investigated and compared between the two modes that the process can be operated. For the floc characteristics, the creation and stability of the flocs were investigated, and the particle size, size distribution and zeta potential was identified as important properties and thereafter analysed using the instrument zetasizer. The concentration of eleven different PFAS compounds were analysed. The results of floc characteristics show that there is no major difference in creation and breakage of flocs in the two investigated modes, since the analysed samples had the same zeta potential, -6.45 mV. The results were deemed uncertain because of varying results, and improvement suggestions include using photoanalysis to confirm similar floc appearances and to produce more data so a statistical validity can be quantified. As for the PFAS concentration, the concentration of PFAS were slightly lower in the treatment step in which sedimentation was utilized (7.5 ng/l) compared to when flotation was utilized (9.2 ng/l). The flotation mode did, however, create foam with a high PFAS concentration (3800 ng/l) compared to the liquid samples (5.5-9.2 ng/l), so a potential PFAS removal source was identified. The results were based on one sample series, so improvements of validity can be achieved by gathering more data, analysing more samples, and analysing the same sample in two different instruments measuring PFAS concentrations.
Dlangamandla, Cynthia. "Bioflocculant dissolved air flotation system for the reduction of suspended solids-lipids-Proteinaceous matter from poultry slaughterhouse wastewater." Thesis, Cape Peninsula University of Technology, 2016. http://hdl.handle.net/20.500.11838/2485.
Full textPoultry slaughterhouse wastewater (PSW) contains organic matter that can be degraded by microorganisms. Such matter can further be used by the microbial community as a nutrient source for growth. Moreover, this type of wastewater also contains a high quantity of particulate matter, lipids and proteins, including antimicrobial compounds such as triclosan (TCS) and trichlorocarbanilide (TCC) used during cleaning and sanitising of processing facilities. Lipids and particulate matter lead to clogging of pipes and fouling of diffusers in the wastewater treatment plants (WWTPs). To overcome this problem, a pre-treatment system such as a dissolved air flotation system (DAFs) in which synthetic flocculants are used, is commonly used prior to the biological treatment of the wastewater. Synthetic flocculants add to the environmental burden associated with the use of synthetic compounds, particularly when these compounds are used in WWTPs. This study focused on the reduction of suspended solids, lipids and proteinaceous matter using a bioflocculant- supported DAF for the treatment of PSW.
Mukandi, Melody. "Modelling of a bioflocculant supported dissolved air flotation system for fats oil and grease laden wastewater pretreatment." Thesis, Cape Peninsula University of Technology, 2017. http://hdl.handle.net/20.500.11838/2637.
Full textIn the recent past, the poultry industry in South Africa has grown due to an increased demand of poultry products as a result of population growth and improved living standards. Furthermore, this has led to poultry slaughterhouses generating high strength wastewater which is laden with a high concentration of organic and inorganic pollutants from the slaughtering process and sanitation of equipment and facilities. As a result, South Africa has promulgated restrictions and a set of quality standards for effluent discharged into the environment to minimize ecological degradation and human health impact. Hence, there is a need for improved Poultry Slaughterhouse Wastewater (PSW) pre-treatment prior to either discharge into municipal wastewater treatment plants (WWTP) or on-site secondary treatment processes such as anaerobic digesters. Additionally, amongst the pre-treatment methods for Fats, Oil and Grease (FOG) laden wastewater, flotation remains the most popular with Dissolved Air Flotation (DAF) system being the most applied. However, modelling and optimization of a biological DAF system has never been attempted before in particular for a bioflocculant supported DAF (BioDAF) for PSW pre-treatment. Process modelling and optimization involves process adjustment to optimize influential parameters. In this study, Response Surface Methodology (RSM) was used to develop an empirical model of a BioDAF for pre-treatment of PSW, for which a bioflocculant producer including production conditions, flocculant type and its floc formation mechanism, were identified. Twenty-one (n = 21) microbial strains were isolated from the PSW and their flocculation activity using kaolin clay suspension (4g/L) was quantified, with a mutated Escherichia coli (mE.coli) [accession number LT906474.1], having the highest flocculation activity even in limited nutrient conditions; hence, it was used for further analysis in other experiments. Furthermore, the optimum conditions for bioflocculant production achieved using RSM were pH of 6.5 and 36°C conditions which induced instantaneous bioflocculant production with the highest flocculation activity. The bioflocculant produced by the mE.coli showed the presence of carboxyl/amine, alkyne and hydroxyl functional groups, which was indicative that the bioflocculant contained both polysaccharides and some amino acids.
Magalhães, Aléx Fabiano Ribeiro de. "Proposição, implantação, partida e ajustes de reatores biologicos e fisico-quimicos para tratamento e reciclagem de efluentes de lavadores de veiculos em escala real." [s.n.], 2005. http://repositorio.unicamp.br/jspui/handle/REPOSIP/258217.
Full textDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo
Made available in DSpace on 2018-08-04T11:01:23Z (GMT). No. of bitstreams: 1 Magalhaes_AlexFabianoRibeirode_M.pdf: 2242026 bytes, checksum: b4ae2e107eb7317d892ade5a7815f862 (MD5) Previous issue date: 2005
Resumo:Com a intenção de preencher a lacuna decorrente de poucos estudos sobre o tratamento de efluentes da lavagem de veículos, na presente pesquisa, propõe-se um sistema de tratamento composto de biofiltros aerados submersos seguidos por flotação por ar dissolvido na remoção dos principais contaminantes contidos nos mesmos. Para isso, foi concebida, instalada e operada uma instalação protótipo em escala real, visando possibilitar a reutilização do efluente tratado. O sistema foi montado em uma transportadora e destinado ao tratamento dos efluentes de lavagens de caminhões tipo baú através de lavador tipo ¿rollover¿. Apesar de terem sido previstos três meses para a operação do sistema, vários problemas de origem operacional do próprio lavador de veículos impediram a realização dos testes de longa duração. Mesmo assim, o período de testes foi útil para estabelecer-se quais alterações físicas deveriam ser incorporadas à instalação proposta para a solução de diversos problemas específicos relativos à concepção original do sistema, subsidiando dados para a otimização de futuros sistemas a serem implantados em escala real. Concluiu-se que, após as modificações introduzidas, tais como a alteração de dispositivos de entrada e saída dos reatores, substituição de acessórios de controle de pressão e vazão, entre outros, a alternativa proposta para tratamento e reúso deste tipo de efluente é plenamente viável
Abstract: With the intention to contribute for aim of filling out the emptiness provoked by few studies on the treatment of carwash affluent, in this research, it intends to create a treatment system composed of aerated submerged biological filter (BAS) following for the dissolved air flotation (FAD) on the removal of the main pollutants present in this effluent type. For that, it was become designed, installed and operated an installation prototype in real scale, seeking the water recycling. The system was installed at cargo transport interprise and destined to the treatment of the carwash effluent type "rollover". In spite of it have been preview three months for the operation time of the system, several operational problems of the washer accomplish of the long time tests. Even so, the time of tests was useful to establish which physical alterations should be incorporate in the installation proposed for the solution of problems to the original conception of the system, subsidizing data for the otimization of the future systems to be implanted in real scale. This research was finish, after the modifications, such as the alteration of inlet and outlet devices of the reactors, pressure and flow control, among other, the proposal alternative for treatment and reuse of rollover type carwash effluent type is fully viable
Mestrado
Saneamento e Ambiente
Mestre em Engenharia Civil
Vašalovská, Petra. "Modelový výzkum účinnosti separačních technologií úpravy vody." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2012. http://www.nusl.cz/ntk/nusl-225461.
Full textPetiraksakul, Anurak. "The efficiency of particle removal by dissolved air flotation." Thesis, Loughborough University, 1999. https://dspace.lboro.ac.uk/2134/11168.
Full textAl-Shamrani, Abdullah A. M. "Destabilisation of oil-water emulsions and separation using dissolved air flotation." Thesis, University of Manchester, 2002. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.488142.
Full textMcLoughlin, Liam. "A comparative study of flocculative water treatment by dissolved air flotation and sedimentation." Thesis, Queen's University Belfast, 1996. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.284679.
Full textSjölander, Anna. "The effect of water chemistry and fibre-size distribution on dissolved air flotation efficiency." Thesis, Linköping University, Department of Physics, Chemistry and Biology, 2009. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-19306.
Full textThe purpose of this diploma work was to investigate the problem of insufficient fibre recovery in the dissolved air flotation-cell at the new thermomechanical pulping-line at Braviken Paper Mill. An investigation of the effect of process parameters on the removal efficiency in the micro-flotation process was undertaken.
The experiments were carried out for two setups at the Noss pilot plant with a small-scale flotation unit. Factorial design helped plan the experiments and four factors were controlled; temperature, fibre-size distribution, water quality and feed concentration. Three samples, feed, overflow and filtrate, were taken from each experiment and concentration measurements were made. The results were analyzed using the software MODDE.
The results from showed an influence from the fibre-size distribution. To see if the fibre-size distribution really had an effect on the results, follow-up experiments were carried out. These experiments showed no influence from temperature, fibre-size distribution or water quality. This concludes that none of those three factors influenced the results significantly.
Additional experiments were done to examine the influence from concentration and fibre-size distribution on the flotation efficiency and these showed an influence from the feed concentration. When increasing the feed concentration the efficiency of the flotation process decreased.
Mohamad, Radzi Aliff R. "Removal of oil droplets from oil-in-water mixtures by dissolved air flotation (DAF)." Thesis, University of Surrey, 2017. http://epubs.surrey.ac.uk/813553/.
Full textBakeev, Emil Almazovich. "The risk of tank geometry on the performance of dissolved air flotation in portable water treatment." Thesis, University of Newcastle Upon Tyne, 2003. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.268363.
Full textGonzalez, Galvis Juan Pablo. "Development of a Large Batch Bench-Scale Dissolved Air Flotation System for Drinking Water Treatability Tests." Thesis, Université d'Ottawa / University of Ottawa, 2019. http://hdl.handle.net/10393/39336.
Full textSlacke, Mark Philip. "The potential use of lignin Mannich bases as flocculating agent in white water clarification using dissolved air flotation." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1998. http://www.collectionscanada.ca/obj/s4/f2/dsk2/tape17/PQDD_0005/MQ33754.pdf.
Full textSartori, Luci. "Influência do uso de polímeros sintéticos no desempenho da flotação por ar dissolvido aplicada no tratamento de água para abastecimento." Universidade de São Paulo, 1998. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-12092016-105327/.
Full textThe usage of synthetic polymers as flocculation aids for the treatment of supply water is a practice which have been widely stimulated, however its usage in flocculation aiming supply water flocculation has been scarcely studied. This work presents the results of the study of the influence of synthetic polymer application as a flocculation aids for clarifying prepared water containing high levei of color (100 ± 9.0 CU) and low turbidity (6.80 ± 1.0 NTU) through flotation. Three different kinds of polymers were investigated - cationic, anionic and non-ionic - which were applied together with the primary cogulant (aluminium sulphate). After the optimization of this coagulant dosage (40 mg/L), without the utilization of polymers, it was studied the flotation performance by the reduction of the coagulant dosage together with the application of different polymer dosages. It was also studied the influence of the time after rapid mixing for the polymer addition, and of time and average velocity gradient and flotation. Two units of dissolved air flotation were used, a bench unit and a pilot plant unit (with continuous flow). After the flocculation parameters adequacy, the essays obtained with FLOTATESTE showed that the application of 0.5 mg/L of non-ionic polymer allowed a reduction of 50% on coagulant dosage, without meningful drops of the color and turbidity removal efficient (96% and 93% respectively). On the other hand, the cationic polymer, at 0.25 mg/L, enabled a 70% reduction on the aluminium sulphate dosage with color and turbidity removal efficiency of 90%. The plant flotation unit, operating under a flow rate of 262 m3/m2d and with polymer application, under conditions optimized by FLOTATESTE, was able to provide good results of colour removal (82% and effluent color of 18.6 CU) and turbicity removal (83% with turbicity of 1.23 NTU in the effluent). In the essays with the pilot plant flotation unit, operating under a flow rate of 525 m3/m2d after reduction of 70% on the coagulant dosage (application of 0,25 mg/L of cationic polymer) , an up to 79% reduction in mass of sludge generated was observed.
Paz, Júnior Gilberto José da [UNESP]. "Uso de floculador hidráulico de manta de lodo acoplado a flotador por ar dissolvido no tratamento de água de abastecimento." Universidade Estadual Paulista (UNESP), 2009. http://hdl.handle.net/11449/98069.
Full textCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Novas tecnologias para o tratamento de água vêem sendo desenvolvidas e suas combinações podem apresentar bons resultados principalmente quando submetidas a variações sazonais de origem natural e antropicas. A crescente poluição dos corpos d’água causa florescimentos de algas e cianobactérias nos mananciais, com aparecimento de sabor e odor na água bruta, podendo ocorrer também a liberação de toxinas pelas cianobactérias. Os processos de tratamento de água convencionais têm apresentado deficiências quanto à remoção de cianobactérias e cianotoxinas, principalmente quanto ao aspecto de remoção das células viáveis e na capacidade de remover as toxinas extracelulares. As cianobactérias retidas no lodo dos decantadores representam riscos à qualidade final da água tratada. O presente projeto de pesquisa consistiu em experiência com floco-decantador de manta de lodo acoplado a flotador por ar dissolvido, formando um conjunto composto pelos dois tipos de equipamentos ou tecnologias e ainda com dispositivo limitador de manta. O objetivo da pesquisa foi avaliar o desempenho da instalação proposta quando submetida a variações da qualidade da água bruta, principalmente quando submetido à sobrecarga de algas e cianobactérias, simulando possíveis florações nos mananciais. Os resultados dos ensaios no modulo experimental com água natural apresentaram remoção satisfatória de turbidez , com valores abaixo de 3,0 uT da água floco-floto-decantada e em torno de 0,1 uT da água filtrada. Os ensaios realizados com água natural com presença elevada de algas e cianobactérias, evidenciaram a importância da unidade de flotação, com remoção de clorofila_a de 82% na água decantada/flotada e próximo de 99% na água filtrada, em relação à água bruta, sendo que a turbidez manteve-se abaixo de 3 uT na saída do modulo floco-floto-decantador e a turbidez...
New technologies for water treatment have been developed and their combinations can produce good results especially when subjected to seasonal variations of natural and anthropogenic. The increasing pollution of water bodies causes blooms of algae and cyanobacteria in water sources, with the appearance of taste and odor in raw water, but may also occur the release of toxins by cyanobacteria. The processes of conventional water treatment have shown deficiencies in the removal of cyanobacteria and cyanotoxins, especially on the aspect of removal of viable cells and the ability to remove extracellular toxins. Cyanobacteria retained in the sludge of the sedimentation tanks pose to the final quality of treated water. This research project was to experiment with floc-settling sludge blanket coupled to dissolved air flotation, forming a group composed of two types of equipment or technology, and with relief device blanket. The research aimed to evaluate the performance of the proposed development when subjected to variations in raw water quality, especially when subjected to the overload of algae and cyanobacteria to simulate possible blooms in the springs. The results of tests on an experimental module with natural water showed satisfactory removal of turbidity, with values below 3 uT decanted and around 0,1 uT filtered water. Tests conducted with water with high presence of algae and cyanobacteria, have highlighted the importance of unity flotation Chlorophyll “a” with removal of 82% in the decanted water / rappel and around 99% in filtered water compared to raw water, and the turbidity remained below 3 uT the output of modulo-flake-floto sedimentation and turbidity of filtered water was below 0,6 uT. The limiting device of the ground and periodic removal of sludge, decreased the retention time of the cells retained in the sludge which may have prevented the release of toxins into the water... (Complete abstract click electronic access below)
Chaves, Karina Oliveira. "Desenvolvimento e aplicaÃÃo de sistema de Floco-FlotaÃÃo por Ar Dissolvido para tratamento de Ãgua de lavagem do filtro da ETA GaviÃo." Universidade Federal do CearÃ, 2012. http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=8123.
Full textNo cenÃrio brasileiro, os resÃduos de EstaÃÃes de Tratamento de Ãgua (ETAs) sÃo normalmente lanÃados in natura em corpos hÃdricos, apresentando-se como potencialmente danosos ao meio ambiente, sendo necessÃrio tratÃ-los para que sejam descartados conforme os aspectos legais. Estudos demonstram que a tecnologia da FlotaÃÃo por Ar Dissolvido (FAD) tem sido viÃvel para este fim. Acredita-se que a incorporaÃÃo da floculaÃÃo em cortinas numa mesma unidade de flotaÃÃo possa promover elevada eficÃcia ao sistema, traduzindo-se como uma inovaÃÃo tecnolÃgica: o Floco-Flotador por Ar Dissolvido (FFAD). Uma unidade piloto de FFAD foi construÃda para o tratamento da Ãgua de lavagem dos filtros da ETA GaviÃo, pertencente à Companhia de Ãgua e Esgoto do Cearà (CAGECE). Esta pesquisa teve como objetivo quantificar e verificar o atendimento da Ãgua de lavagem dos filtros (ALF) desta ETA e da Ãgua clarificada via FFAD aos padrÃes de lanÃamento de efluentes conforme as ResoluÃÃes n 430/11 e 357/05 do CONAMA e Portaria n 154/2002 da SEMACE. Estudos de tratabilidade da ALF em Jartest foram realizados para avaliar a influÃncia da dosagem de polÃmeros catiÃnicos e a viabilidade de gradientes de velocidade decrescente (35 a 5,6 s-1) a serem empregados no equipamento de FFAD desenvolvido. Ensaios de flotaÃÃo foram realizados a fim de avaliar a dosagem do polÃmero e os parÃmetros de processo como taxas de recirculaÃÃo (TR) e taxas de aplicaÃÃo superficial (TAS). ApÃs definidos estes parÃmetros, ensaios de FFAD foram realizados em triplicata para coleta da AC a fim de comparÃ-la com os principais padrÃes de lanÃamento de efluente em corpos hÃdricos classe II. Somente os parÃmetros pH, Fluoreto, AmÃnia, E. coli e SÃlidos dissolvidos da ALF atenderam aos padrÃes de lanÃamento. Ao aplicar polÃmero a 1 mg.L-1, taxa de recirculaÃÃo de 15%, gradientes de velocidade decrescente (19,3 a 5,6 s-1), taxa de aplicaÃÃo superficial de 57 m3.m-2.d-1 com tempo de detenÃÃo hidrÃulico de 22 minutos no FFAD, os resultados alcanÃaram elevada eficiÃncia na remoÃÃo de turbidez (superior a 98%) mesmo enfrentando variaÃÃes bruscas na qualidade da ALF (94,4 a 410 UT). Observou-se tambÃm significativa eficiÃncia mÃdia na remoÃÃo de coliformes totais (98,5%), cor aparente (97,6%), DQO (92,6%) e remoÃÃo de alumÃnio (84,1%). Diante destes resultados, constatou-se que a ALF da ETA GaviÃo tratada via Floco-flotaÃÃo por ar dissolvido atendeu aos referidos padrÃes de lanÃamento em corpos hÃdricos.
In Brazil the filter backwash wastewater is normally released in to the water resources without proper treatment, representing a potential danger to the environment. Thus, it is necessary to treat this wastewater in order to dispose it in accordance to federal and state environmental laws. Studies show that Dissolved Air Flotation (DAF) technology has been feasible for this purpose. It is believed that the incorporation of flocculation in curtains and air dissolved flotation system in the same unit can promote high efficiency and significant size reduction, which translates in a technological innovation: the Floculator - Dissolved Air Flotation (FFAD) unit. A FFAD pilot unit was built to evaluate the treatment of GaviÃo Water Treatment Plant filter backwash wastewater, owned by the Water and Wastewater Company of Cearà (CAGECE). This research had as main objective to quantify and verify the compliance of the filter backwash wastewater parameters to the Resolution No. 430/11 and 357/05 of CONAMA and Ordinance No. 154/2002 of SEMACE. Treatability studies were performed with filter backwash wastewater using Jartest to evaluate the influence of cationic polymer dosages and the feasibility of decreasing flocculation velocity gradients (35 to 5.6 s-1) in the FFAD. Experimental runs of the flocculation - flotation system were performed to evaluate the best polymer dosage and the process parameters such as recirculation rates (TR) and surface application rates (TAS). These parameters were compared by observing the lower residual turbidity and best removal efficiency in the clarified water (AC). The treated wastewater was again characterized using physicalchemical and bacteriological parameters and compared to the specific legislation. The results showed that the use of 1 mg.L-1 of polymer, recirculation rate of 15% and surface application rate of 57 m3.m-2.d-1, presented the highest turbidity efficiency removal (> 98%) and a very stable performance against sudden changes in the influent quality (94.4 to 410UT). It should be noted that the unity showed also a high average efficiency total coliforms removal (98.5%), apparent color removal (97.6%), DOC removal (92.6%), of aluminum (84.1%) removal and turbidity (99.2 %) removal. Given these results, it was concluded that the AC coming from the treatment of ALF by ETA WTP GaviÃo FFAD met the discharge parameters listed for water resources.
Paz, Júnior Gilberto José da. "Uso de floculador hidráulico de manta de lodo acoplado a flotador por ar dissolvido no tratamento de água de abastecimento /." Ilha Solteira : [s.n.], 2009. http://hdl.handle.net/11449/98069.
Full textBanca: Dib Gebara
Banca: Carlos Gomes da Nave Mendes
Resumo: Novas tecnologias para o tratamento de água vêem sendo desenvolvidas e suas combinações podem apresentar bons resultados principalmente quando submetidas a variações sazonais de origem natural e antropicas. A crescente poluição dos corpos d'água causa florescimentos de algas e cianobactérias nos mananciais, com aparecimento de sabor e odor na água bruta, podendo ocorrer também a liberação de toxinas pelas cianobactérias. Os processos de tratamento de água convencionais têm apresentado deficiências quanto à remoção de cianobactérias e cianotoxinas, principalmente quanto ao aspecto de remoção das células viáveis e na capacidade de remover as toxinas extracelulares. As cianobactérias retidas no lodo dos decantadores representam riscos à qualidade final da água tratada. O presente projeto de pesquisa consistiu em experiência com floco-decantador de manta de lodo acoplado a flotador por ar dissolvido, formando um conjunto composto pelos dois tipos de equipamentos ou tecnologias e ainda com dispositivo limitador de manta. O objetivo da pesquisa foi avaliar o desempenho da instalação proposta quando submetida a variações da qualidade da água bruta, principalmente quando submetido à sobrecarga de algas e cianobactérias, simulando possíveis florações nos mananciais. Os resultados dos ensaios no modulo experimental com água natural apresentaram remoção satisfatória de turbidez , com valores abaixo de 3,0 uT da água floco-floto-decantada e em torno de 0,1 uT da água filtrada. Os ensaios realizados com água natural com presença elevada de algas e cianobactérias, evidenciaram a importância da unidade de flotação, com remoção de clorofila_a de 82% na água decantada/flotada e próximo de 99% na água filtrada, em relação à água bruta, sendo que a turbidez manteve-se abaixo de 3 uT na saída do modulo floco-floto-decantador e a turbidez... (Resumo completo, clicar acesso eletrônico abaixo)
Abstract: New technologies for water treatment have been developed and their combinations can produce good results especially when subjected to seasonal variations of natural and anthropogenic. The increasing pollution of water bodies causes blooms of algae and cyanobacteria in water sources, with the appearance of taste and odor in raw water, but may also occur the release of toxins by cyanobacteria. The processes of conventional water treatment have shown deficiencies in the removal of cyanobacteria and cyanotoxins, especially on the aspect of removal of viable cells and the ability to remove extracellular toxins. Cyanobacteria retained in the sludge of the sedimentation tanks pose to the final quality of treated water. This research project was to experiment with floc-settling sludge blanket coupled to dissolved air flotation, forming a group composed of two types of equipment or technology, and with relief device blanket. The research aimed to evaluate the performance of the proposed development when subjected to variations in raw water quality, especially when subjected to the overload of algae and cyanobacteria to simulate possible blooms in the springs. The results of tests on an experimental module with natural water showed satisfactory removal of turbidity, with values below 3 uT decanted and around 0,1 uT filtered water. Tests conducted with water with high presence of algae and cyanobacteria, have highlighted the importance of unity flotation Chlorophyll "a" with removal of 82% in the decanted water / rappel and around 99% in filtered water compared to raw water, and the turbidity remained below 3 uT the output of modulo-flake-floto sedimentation and turbidity of filtered water was below 0,6 uT. The limiting device of the ground and periodic removal of sludge, decreased the retention time of the cells retained in the sludge which may have prevented the release of toxins into the water... (Complete abstract click electronic access below)
Mestre
Pioltine, Andre. "Influência do tamanho de partículas floculadas na eficiência da clarificação de águas para abastecimento por flotação." Universidade de São Paulo, 2013. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-06062013-113030/.
Full textThe goal of this research was to investigate the flocculated particles size distribution influence on the dissolved air flotation (DAF) efficiency. Special image acquisition method and equipment were used to characterize the flocculated particles and air microbubbles size distribution, as well as, the clusters (in terms of microbubbles number adhered and rise velocity) in the contact zone outlet of the DAF unit. Besides that, the experimental results were compared with those obtained from the DAF modeling proposed by Reali (1991). The trials were carried out with synthetic water (temperature of 26.0 ± 0.5oC; turbidity of 7.5±0.2 NTU; apparent color of 38±1 CU; alkalinity of 29.8±0.6 mg\'CA\'\'CO IND.3\'/L; conductivity of 59.3±0.8 \'mü\'S/cm; UV254nm of 0.128±0.004 \'CM POT.-1\'), that it was coagulated by applying 1.9 mg/L of \'AL POT.3+\' (22.5 mg/L alum). The trials were divided into two phases: Phase 1 - preliminary tests carried out in laboratory facilities (flotatest); Phase 2 - tests carried out in pilot facilities (DAF pilot unit). The results showed that: i) the flocculation conditions interfered directly on the efficiency of DAF process, and the best flocculation conditions were those that conducted to formation of flocculated particles size with Feret mean diameter above 300 \'mü\'m; ii) the best results were obtained applying flocculation time of 17 min, however, DAF was also capable of operating with a satisfactory efficiency when applying flocculation time of 10 min; iii) the special image acquisition method and equipment developed in this research proved to be a important tool to characterize the flocculated particles and air microbubbles size distribution, as well as, the number of air microbubbles adhered to the flocs surface and the clusters rise velocity; iv) the DAF modeling developed by Reali (1991) provided a reliable prediction of the microbubbles number adhered to the flocs surface, as well as, the clusters rise velocity.
Oliveira, Gislayne Alves. "REMOÇÃO DE CIANOBACTÉRIAS DE ÁGUAS POR PROCESSO DE FLOTAÇÃO POR AR DISSOLVIDO." Universidade Federal de Santa Maria, 2016. http://repositorio.ufsm.br/handle/1/7655.
Full textHuman activities generate qualitative and quantitative impacts of water resources which vary in intensity with the occupation and urbanization of a watershed, create a big problem due to the high concentration of nutrients. The nutrients released into waterways, when they exceed the limit self-purification of water resources can cause algal blooms and the development of cyanobacteria, which can be toxic organisms and has been negatively highlighting the water treatment system for public supply. This is because the conventional treatments are not effective for the removal of the cyanobacteria, and cause harmful effects to human health, but often the conditions are more precarious not occurring treatment before consumption. Many chemical agents used in the treatment can be reacted with cyanobacteria, causing cell lysis (breakage) worsening the dispersion of toxins in water. Accordingly, it was evaluated the removal efficiency of Dolichospermum cylindrica cyanobacterial species, as well as identify the best operating conditions and comparison of the application of natural coagulant - tannin with aluminum sulfate, using dissolved air flotation (DAF). The experiments were developed in bench scale using the equipment: pitchers test (coagulation / flocculation) and the bench flotation (DAF). The tests were conducted at different phases when using the two tested coagulants. In the first step we tried to determine the zeta potential of cyanobacteria, in the second part we build the coagulation diagram (pH coagulation x coagulant dosage), followed by flocculation tests which sought better results for the velocity gradient (Gf) and time flocculation (Tm) and at the end evaluate the FAD testing the design parameters such as saturation pressure (Psat), recirculation rate (R) and flotation velocity (Vf). The performance of the treatment system was evaluated from the cell count. The results show that the cells of cyanobacteria had no change in zeta potential in relation to different pH ranges, and negative behavior ranging from -25.7 to -20.1 mV. In the construction of the coagulation diagram aluminum sulfate coagulation showed a broad pH range (4.5 to 9), reducing a bit pH range when used as the tannin coagulant (6-9). Both coagulants showed excellent results using the DAF, but aluminum sulfate showed higher removal (97.93%), even with the lowest removal (87.97%) tannin ends up being more suitable for being biodegradable, and having adsorption capacity for metals in the water. In relation to the parameters of this design, it was noticed that it is better removal using aluminum sulphate Gf to 25 s-1, Tm 15 minutes, Psat 300 kPa, and R 10% Vf 2.5 cm.min-1 and tannin Gf 50 s-1, Tm 10 minutes, Psat 300 kPa, and R 15% Vf 2 cm.min-1. In general, FAD has shown good results for your application in the removal of cyanobacteria.
As atividades humanas geram impactos quali-quantitativos nos recursos hídricos que variam de intensidade com a ocupação e urbanização de uma bacia hidrográfica, gerando um grande problema devido à alta concentração de nutrientes. Os nutrientes lançados nos cursos d água, quando superam o limite de autodepuração dos recursos hídricos podem provocar a proliferação de algas e o desenvolvimento de cianobactérias, que são organismos que podem ser tóxicos e vem se destacando negativamente no sistema de tratamento de água para abastecimento público. Isso porque os tratamentos convencionais não são eficientes para a remoção das cianobactérias, e provocam efeitos deletérios à saúde humana, porém muitas das vezes as condições são mais precárias não ocorrendo o tratamento antes do consumo. Muitos agentes químicos utilizados no tratamento podem reagir com as cianobactérias, provocando a lise celular (rompimento) agravando a dispersão de toxinas na água. Nesse sentido, avaliou-se a eficiência na remoção de cianobactérias da espécie Dolichospermum cylindrica, assim como identificação das melhores condições de operação e comparação da aplicação do coagulante natural - tanino com o sulfato de alumínio, utilizando a flotação por ar dissolvido (FAD). Os experimentos foram desenvolvidos em escala de bancada utilizando os equipamentos: teste de jarros (coagulação/floculação) e o flotador de bancada (FAD). Os testes foram realizados em fases distintas sempre utilizando os dois coagulantes testados. Na primeira etapa procurou-se determinar o potencial zeta das cianobactérias e na segunda etapa construir o diagrama de coagulação (pH de coagulação x dosagem de coagulante), seguido dos testes de floculação a qual buscou melhores resultados para o gradiente de velocidade (Gf) e tempo de floculação (Tf) e por final avaliar a FAD testando os parâmetros de projeto como pressão de saturação (Psat), taxa de recirculação (R) e velocidade de flotação (Vf). O desempenho do sistema de tratamento foi avaliado a partir da contagem das células. Os resultados mostram que as células de cianobactéria não tiveram variação no potencial zeta em relação a diferentes faixas de pH, tendo um comportamento negativo variando de -25,7 a -20,1 mV. Na construção do diagrama de coagulação o sulfato de alumínio apresentou uma ampla faixa de pH de coagulação (4,5-9), reduzindo um pouco a faixa de pH quando utilizado o tanino como coagulante (6-9). Ambos os coagulantes apresentaram resultados excelentes utilizando a FAD, porém o sulfato de alumínio apresentou remoções mais elevadas (97,93%), mesmo com a remoção mais baixa (87,97%) o tanino acaba sendo mais indicado por ser biodegradável, além de ter a capacidade de adsorção de metais presentes na água. Em relação aos parâmetros de projeto avaliados, verificou-se melhores remoções utilizando o sulfato de alumínio para Gf 25 s-1, Tf 15 min, Psat 300 kPa, R 10% e Vf 2,5 cm.min-1 e para o tanino Gf 50 s-1, Tf 10 min, Psat 300 kPa, R 15% e Vf 2 cm.min-1. A FAD de modo geral apresentou bons resultados para sua aplicação na remoção de cianobactérias.
Rosa, Andrey Alexsandro. "Pré-cloração associada à adsorção em carvão ativado em pó e flotação por ar dissolvido na remoção de microcistina presente em três diferentes concentrações em águas provenientes de reservatório eutrofizado." Universidade de São Paulo, 2008. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-11072008-154329/.
Full textThe disordered growth of cities, the use of planting areas near the water sources and the launch of domestic and industrial wastewater without treatment are the main sources of water bodies\' pollution. Such pollution contributes to increase the nutrient loading in the water bodies. In association with climatic factors, this enrichment of nutrient provides suitable conditions for the bloom of potentially toxic algae. Thus, increases the concern over to develop treatment techniques that provide water quality able to ensure the health of the consumer population. In this research, waters were prepared with different concentrations of microcystin and some treatments were tested in bench scale. These tests consisted in prechlorination, adsorption on powdered activated carbon, coagulation/flocculation, dissolved air flotation and centrifugation. The diagram of treatment with activated carbon application after the rapid mix showed better results of apparent color, turbidity and residual concentration of microcystin. The influence of the concentration of microcystin in the simulated treatments was evaluated. It was found that for 104.92 µg/L of microcystin the application of 3.0 mg\'CL IND.2\'/L (10 seconds before rapid mix) and 30 mg/L of PAC (after a quick mixture) were not able to reduce the concentration of microcystin to less than 1 µg/L, as the limit established by Order 518/04 of the Health Ministry. Thus, it was decided to estimate the minimum dosage of powdered activated carbon (PAC) according to the initial concentration of microcystin found in the three prepared waters. The residual concentration of microcystin in each water, after the estimated dosage application of PAC was: Water 1 = 0.80 µg/L; Water 2 = 0.82 µg/L; Water 3 = 0, 23 µg/L.
Julio, Marcelo De. "Efeito da massa molecular das substâncias húmicas na eficiência da coagulação com o reagente de Fenton, floculação e flotação de águas de mesma cor verdadeira." Universidade de São Paulo, 2005. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-10102016-151804/.
Full textHumic substances\' presence in water destined for supply has brought many problems, such as halogenated byproducts formation, mainly when chlorine is used as preoxidant. With Fenton\'s reagent there is no formation possibility of these undesirable halogenated compounds, since the strong oxidative power of Fenton\'s reagent is due to hydroxyl radical (OH). In addition, with the same chemical product, it is possible to have the preoxidation and coagulation of organic compounds, because Fenton\'s reagent consists of Fe+2 ions and hydrogen peroxide application under acid conditions, with Fe+2 oxidized to Fe+3. Since these ions form hydrolyzed species that act as coagulants, Fenton\'s reagent can have the double function of oxidation and coagulation on treatment processes. Because of this, the current work proposed a methodology to use Fenton\'s reagent as coagulant agent in the treatment of waters having high true color caused by the introduction of humic substances extracted by peat. Besides this, humic substances molecular weight effect on coagulation, flocculation and flotation of waters was studied; for this, 4 distinct waters having the same true color were prepared, but with different humic substances molecular weights, obtained by ultrafiltration fractioning. Through optimization of coagulant dosage and respective coagulation pH and posterior construction of coagulation diagrams for each studied water, it was verified that the water prepared withthe smallest molecular weight humic substances was more difficult to treat, requiring higher coagulant (Fenton\'s reagent) dosages compared with the waters prepared with larger molecular weight humic substances. Furthermore, experiments of filtration after flotation were carried out, trying to simulate a complete cycle treatment, which verified that with Fenton\'s reagent, employed as coagulant agent, the filtered water reached the brazilian potable standards concerning the measured parameters (apparent color < ou = 3 HU, turbidity < 0.5 TU and residual total iron < 0.005 mg/L). The absorbance and total organic carbon values of filtered water were also very low, indicating that the disinfection byproducts formation with chlorine would be insignificant.
Oliveira, Nilton Fernandes de. "Avaliação da qualidade da água de lavagem de filtros e de lodo de decantador após tratamento sequencial por leito de drenagem, flotação por ar dissolvido e filtração." Universidade Federal de Uberlândia, 2015. https://repositorio.ufu.br/handle/123456789/14212.
Full textIn this study, we evaluated the quality of filter backwash water and sludge decanter Water Bom Jardim Treatment Plant, located in Uberlandia, Minas Gerais, after sequential treatment with drainage bed, flotation and filtration dissolved air, all bench scale. Compounds were evaluated drainage bed effluent three different types of geotextile webs: RT-21, RT-26 and RT-31, and tested three kinds of constituents of the sand grain size filters. The effluent drained, after passage through the drainage bed, passed through the flotation unit dissolved air and then by filtration units. Preliminary tests with crude sample of filter backwash water and sludge decanter, in order to characterize it and evaluate it as its physical, chemical and biological were performed. The geotextile webs used were chosen from results of previous studies, performed with the same type of system. The experiments were divided into stages I and II. In step I were conducted without addition of coagulant or auxiliary experiments on coagulation / flocculation flotation. The samples, after passage through the system, evaluating physical parameters pH, turbidity, true color and apparent color and about the chemical parameters, remaining concentrations of aluminum and iron. Step II The same tests were carried out in the same step I and determination of quality parameters, however, with aluminum sulphate dose of 5, 10 and 15 mg / L in the coagulation / flocculation flotation. Tests conducted in step I showed better performance were performed with the RT-26 blanket in the output of filter 01 with a reduction of 91.8% of the apparent color, 41.4% of true color and 97.6% turbidity. In phase II trials conducted in the best performance was drained with the RT-mat 26 the output of the filter 02 when subjected to a dosage of 15 mg / L aluminum sulfate as a coagulant agent. There was a reduction of 96.4% of the apparent color, 86.2% of true color and 99.6% turbidity. The presented results confirm the efficiency of the system in removing solids present in the water washing of filters and ETA decanter sludge studied and confirmed the capability of using this system as an alternative to disposal or optionally for a new water supply line treated.
Neste trabalho foi avaliada a qualidade da água de lavagem de filtros e de lodo de decantador da Estação de Tratamento de Água Bom Jardim, localizada na cidade de Uberlândia-MG, após tratamento sequencial por leito de drenagem, flotação por ar dissolvido e filtração, todos em escala de bancada. Foram avaliados efluentes de leitos de drenagem compostos de três tipos de mantas geotêxteis distintas: RT-21, RT-26 e RT-31, e testados três tipos de granulometria de areia constituintes dos filtros. O efluente drenado, após passagem pelo leito de drenagem, passava pela unidade de flotação por ar dissolvido e em seguida pelas unidades de filtração. Foram realizados testes preliminares com amostra bruta da água de lavagem de filtros e de lodo de decantador, com o objetivo de caracterizá-la e avaliá-la quanto as suas características físicas, químicas e biológicas. As mantas geotêxteis utilizadas foram escolhidas a partir de resultados de trabalhos anteriores, realizados com o mesmo tipo de sistema. Os experimentos foram divididos nas etapas, I e II. Na etapa I foram conduzidos experimentos sem adição de agente coagulante ou auxiliares na coagulação/floculação da flotação. As amostras, após passagem pelo sistema, foram avaliadas quanto aos parâmetros físicos pH, turbidez, cor verdadeira e cor aparente e quanto aos parâmetros químicos, concentrações remanescentes de Alumínio e Ferro. Na etapa II foram realizados os mesmos ensaios da etapa I e mesmas determinações dos parâmetros de qualidade, entretanto, com dosagem de sulfato de alumínio de 5, 10 e 15 mg/L na coagulação/floculação da flotação. Os ensaios conduzidos na etapa I que mostraram melhor desempenho foram os realizados com a manta RT-26 na saída do Filtro 01 com redução de 91,8% da cor aparente, 41,4% da cor verdadeira e 97,6% da turbidez. Nos ensaios conduzidos na etapa II o melhor desempenho foi com o drenado da manta RT-26 na saída do Filtro 02 quando submetido a uma dosagem de 15 mg/L de sulfato de alumínio, como agente coagulante. Houve redução de 96,4% da cor aparente, 86,2% da cor verdadeira e 99,6% da turbidez. Os resultados apresentados confirmam a eficiência do sistema na remoção de sólidos presentes na água de lavagem de filtros e de lodo de decantador da ETA estudada, e confirmam a potencialidade de utilização deste sistema como alternativa ao descarte e como opção de nova linha de fornecimento de água tratada.
Mestre em Engenharia Civil
Dobiáš, Pavel. "Flotace rozpuštěným vzduchem – od poloprovozního modelu po plnou realizaci." Doctoral thesis, Vysoké učení technické v Brně. Fakulta chemická, 2018. http://www.nusl.cz/ntk/nusl-385284.
Full textL?do, Patr?cia Guilhermina da Silva. "Flota??o por ar dissolvido na clarifica??o de ?guas com baixa turbidez utilizando sulfato de alum?nio e sementes de Moringa oleifera como coagulantes." Universidade Federal do Rio Grande do Norte, 2008. http://repositorio.ufrn.br:8080/jspui/handle/123456789/15886.
Full textCoordena??o de Aperfei?oamento de Pessoal de N?vel Superior
This work aims to investigate the process of Dissolved air Flotation (DAF) for clarifying water samples with low turbidity using aluminum sulphate and Moringa oleifera seeds as coagulants. The experimental procedure was carried out in a bench scale flotation unit. The influences on the pre-treatment conditions (coagulant dosage and flocculation time) and flotation parameters (superficial application rate and recirculation rate) were evaluated considering the efficiency of the process. The efficiency was evaluated by determining the turbidity of the untreated and treated water samples. The results obtained showed that turbidity reduction can be obtained very efficiently by using DAF and the latter coagulant in low turbidity water. Using aluminum sulphate in pH?s 5.0 and 6.0 better efficiencies were obtained with low concentrations (15 mg/L), achieving values of 92% of turbidity reduction. In the case of use of Moringa oleifera better efficiencies of reduction of turbidity were reported when using a concentration of 50 mg/L in all range of pH?s, achieving 86% of reduction. The zeta potential was also determined, in an attempt to aid comprehension of the coagulation mechanisms involved. The coagulation mechanisms with Moringa oleifera seeds were shown to be adsorption and charge neutralization, as well as adsorption and bridging. Concerning aluminum sulphate, the predominant mechanisms are adsorption and charge neutralization and enmeshment in a precipitate. The results indicate that for low turbidity water, Moringa oleifera seeds could potentially be a viable substitute for aluminum sulphate
O presente trabalho tem como objetivo investigar o processo da flota??o por ar dissolvido sob press?o - FAD para clarifica??o de ?guas com baixa turbidez utilizando sulfato de alum?nio e sementes de Moringa oleifera como coagulantes. O procedimento experimental foi realizado em uma unidade de flota??o em escala de bancada. Foram avaliadas as influ?ncias das condi??es do pr?-tratamento (dosagem de coagulante e tempo de flocula??o) e par?metros de processo da flota??o (taxa de aplica??o superficial e taxa de recircula??o) na efici?ncia do processo. A efici?ncia foi avaliada pela determina??o de turbidez nas amostras de ?gua bruta e tratada. Os resultados obtidos mostraram que elevadas efici?ncias de redu??o da turbidez podem ser conseguidas com o uso da FAD em ?guas com baixa turbidez utilizando estes coagulantes. Para o sulfato de alum?nio, nos pHs 5,0 e 6,0 as melhores efici?ncias foram alcan?adas com baixas dosagens (15 mg/L), alcan?ando valores de at? 92% de redu??o. Para a Moringa oleifera, as melhores efici?ncias de redu??o de turbidez foram ? dosagem aproximada de 50 mg/L para todos os pHs, alcan?ando valores de 86% de redu??o. Determinou-se tamb?m o potencial zeta, com o objetivo de auxiliar na compreens?o dos mecanismos envolvidos na coagula??o. Os mecanismos de coagula??o com sementes de Moringa oleifera indicam ser adsor??o e neutraliza??o de cargas e adsor??o e forma??o de pontes. No que diz respeito ao sulfato de alum?nio os mecanismos predominantes s?o adsor??o e neutraliza??o de cargas e varredura. Os resultados indicam que para ?guas de baixa turbidez, as sementes de Moringa oleifera podem ser um substituto potencialmente vi?vel em rela??o ao sulfato de alum?nio
Souza, Irene Monteiro da Franca. "Influência do gradiente médio de velocidade na zona de contato na eficiência de clarificação de água para abastecimento por flotação." Universidade de São Paulo, 2012. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-17102012-103326/.
Full textThe present work aimed to study the influence of velocity gradient (Gzc) associated with the hydraulic detention time (tzc) and the rate of surface application (TASzc) in the contact zone in the efficiency of clarification of a unit rectangular dissolved air flotation pilot scale, treating water supplies. Two different kinds of configurations of the reactor dissolved air flotation in pilot scale (UPFA) (A and B) were studied, which differ in the length of the contact zone - A (90 mm) and B (140 mm). The TASzc - A (133 ± 3 m/h) and B (86 ± 1 m/h) - and tzc - A (54 ± 1 s) and B (84 ± 1 s) were different. Three different values of Gzc were analysed - A (1.8, 6.5, 10.2 s-1) and B (0.9, 4.7, 6.3 s-1) by insertion of grilles with different characteristics within the zone contact. And for each value of Gzc, three values of A/V (3.73, 4.90, 6.41 g/m³) were investigated. In all trials, the following parameters were set: flow of synthetic raw water (5.4 m³/h), synthetic raw water temperature (26 ± 1ºC), coagulation pH (6.5 ± 0.1); flocculation time (17.2 minutes), the speed gradient flocculation (110 s-1); flow disposal after flocculation (0.8 m³/h), input flow to the flotation (Qe) (4, 6 m³/h), input speed for flotation (ve) (180 m/h), cross-flow velocity (45 m/h), TASzs (14.6 ± 0.2 m/h), saturation pressure (4.5 ± 0.1 kgf/cm ²). The pilot plant was fed with synthetic water, which showed turbidity of approximately 7.4 ± 0.6 NTU, and apparent color, about 39.4 ± 4.3 HU. The removal efficiency of the analyzed parameters for each Gzc is less sensitive to variations in the A/V in the configuration A than in the configuration B. In configuration A, the grille that showed Gzc about 6.5 s-1 gave better results for each A/V analysis. In configuration B, the grille that has generated Gzc around 4.7 s-1 provided the best removal efficiency of turbidity and color for each A/V studied. Furthermore, in the configuration B, the removal efficiency of color and turbidity was less sensitive to variations in A/V for Gzc 4.7 s-1 than for other values of Gzc. The grille that generated the best results in the configuration A was the same for the configuration B. Therefore the use of that grille favored the performance of configurations A and B. Comparing all the situations studied in two configurations, the test with the configuration A (with tzc the 54 s) with Gzc of 6.3 s-1 and A/V of 4.9 g/m³, had the highest removal efficiencies of color and turbidity.
Meca, Karen Soraia. "Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento." Universidade de São Paulo, 2014. http://www.teses.usp.br/teses/disponiveis/18/18138/tde-14112017-104621/.
Full textThe performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.
Steinbach, Sandra. "Dissolution and precipitation of air in dissolved air flotation." Thesis, 2012. http://hdl.handle.net/10210/6178.
Full textThe use of dissolved air flotation (DAF) as a water clarification process has gained momentum over the past two decades. Despite its increased application there is a lack of information concerning the understanding of the underlying principles of the process. Plants are being designed based mainly on empirical guidelines, especially with respect to the bubble production system. Bubbles are generated in the DAF process when water, supersaturated with air under pressure, is released under atmospheric conditions. The efficiency of air dissolution and precipitation determines the quantity of air available for flotation and thus, to a large extent, the success of the whole DAF process. The first part of this thesis deals with a rational model for predicting the air transfer efficiency in packed saturators which are used in most modern DAF plants to dissolve air into water. The model assumes the Lewis-Whitman two-film theory for interfacial mass transfer and uses the Onda correlations to estimate the mass transfer coefficient. The model provides good insight into the effects of key design parameters on the air transfer efficiency. The experimental verification of the model required a method for predicting the saturator air composition and a technique to practically determine the air transfer efficiency in the packed bed of an operating saturator. Both methods are described in detail in this study. The verification of the mass transfer model showed a close agreement of experimental and theoretical results and the model thus provides a powerful tool for the design of packed saturators. The second part of the thesis deals with air precipitation and the quantity of air released after depressurization. Based on a literature review on this subject it was assumed that the air release is incomplete and that it would be a function of the operating conditions of the saturation system as well as of the design of the injection nozzle across which the pressure is released. Since the injection nozzles play an important role in the DAF process numerous experiments were carried out which measured the released air volume for different nozzle configurations and saturator pressures. The results of this study showed that the air release after depressurization is indeed incomplete and that it takes a long time for all the excess air to come out of solution. It was found that the efficiency with which the air was released is a function of the saturator pressure and the nozzle design. The experimental observations led to the formulation of a two-step air release model, which explains the precipitation process in terms of a slow and fast release step. The mathematical framework for quantification of the model is provided. Once the model is quantified it will be possible to compare the performance of different injection nozzles solely with regard to their design features and independent of any parameters influencing the air release downstream of the nozzle. This model may then help to further the understanding of the precipitation process and could lead to the development of some rational guidelines for nozzle design and prediction of nozzle performance.
Rajagopaul, Rachigan. "The evaluation of polymeric organic coagulants for potable water treatment by dissolved air flotation." Thesis, 2001. http://hdl.handle.net/10321/2767.
Full textHistorically inorganic coagulants were the coagulants of choice for OAF treatment of potable water. Water treatment practitioners using OAF technology preferred ferric chloride, an inorganic coagulant. Ferric chloride formed light, floatable floes at relatively low flocculation intensities and detention times. The inorganic coagulant was also more forgiving during incidents of overdosing and raw water and pH variability
M
Bickerton, Benjamin James. "Optimization of Dissolved Air Flotation for Drinking Water Treatment." Thesis, 2012. http://hdl.handle.net/10222/15344.
Full textJaji, Kehinde Temitope. "Treatment of Oilfield Produced Water with Dissolved Air Flotation." 2012. http://hdl.handle.net/10222/15347.
Full text