Dissertations / Theses on the topic 'X-ray simulation method'
Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles
Consult the top 37 dissertations / theses for your research on the topic 'X-ray simulation method.'
Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.
You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.
Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.
Lopresti, Mattia. "Non-destructive X-ray based characterization of materials assisted by multivariate methods of data analysis: from theory to application." Doctoral thesis, Università del Piemonte Orientale, 2022. http://hdl.handle.net/11579/143020.
Full textShinozaki, Osamu, Hirohide Furutani, Masaki Misawa, Naoki Takada, Kazuki Yamauchi, and Kazuhiro Yamamoto. "Lattice Boltzmann simulation on continuously regenerating diesel filter." The Royal Society, 2011. http://hdl.handle.net/2237/20056.
Full textLonie, Sandra. "A molecular dynamics simulation study of diffuse x-ray scattering from Câ†1â†0Hâ†1â†6." Thesis, University of Aberdeen, 1997. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.287696.
Full textLiu, Yu. "Simulation study on PEM fuel cell gas diffusion layers using X-ray tomography based Lattice Boltzmann method." Thesis, Loughborough University, 2011. https://dspace.lboro.ac.uk/2134/9254.
Full textYamamoto, Kazuhiro. "Boundary Conditions for Combustion Field and LB Simulation of Diesel Particulate Filter." Global Science Press, 2013. http://hdl.handle.net/2237/20029.
Full textLiu, Fang. "Monte Carlo modeling of an x-ray fluorescence detection system by the MCNP code." Thesis, Georgia Institute of Technology, 2009. http://hdl.handle.net/1853/33959.
Full textStångberg, Valgeborg Fredrik. "Toward a Novel Gas Cell for X-Ray Spectroscopy : Finite Element Flow Simulation and Raman Characterization." Thesis, Uppsala universitet, Molekyl- och kondenserade materiens fysik, 2019. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-394134.
Full textLester, Sonia. "A study of scattered radiation in diagnostic radiology using Monte Carlo simulation." Thesis, Institute of Cancer Research (University Of London), 1998. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.287993.
Full textHenkel, Thilo Johannes. "Strain-related phenomena in (In,Ga)N/GaN nanowires and rods investigated by nanofocus x-ray diffraction and the finite element method." Doctoral thesis, Humboldt-Universität zu Berlin, 2018. http://dx.doi.org/10.18452/18707.
Full textIn this thesis, nanofocus x-ray diffraction and the finite element method are applied to analyze the local strain field in (In,Ga)N/GaN nanowires and micro-rods which are discussed as candidates for a plethora of future optoelectronic applications. However, to improve and tailor their properties, a fundamental understanding on the level of individual objects is essential. In this spirit, the dependence of the vertical normal component, epsilon_zz, of the elastic strain tensor on the geometry of an axial (In,Ga)N/GaN nanowire is systematically analyzed using the finite element method. Hereby, it is found that if the ratio of nanowire radius and (In,Ga)N segment length approaches unity, a significantly negative epsilon_zz value is observed. This stands in stark contrast to naive expectations and shows that the common knowledge about planar systems where epsilon_zz would always be greater or equal zero cannot easily be translated to nanowires with an equivalent material sequence. As the origin of this effect significant shear strains are discussed which go along with a convex deformation of the outer surface resulting in a highly complex strain distribution. The increased active area of core-shell (In,Ga)N/GaN micro-rods makes them promising candidates for next-generation light emitting diodes. However, it is found that the emission wavelength is significantly red-shifted along the rod height. To shed light on the origin of this phenomenon, nanofocus x-ray diffraction is applied to analyze the local strain field. Due to the high spatial resolution it is possible to investigate the strain field within individual side-facets and to detect a significant gradient along the rod height. Based on the deformation field simulated using the finite element method and subsequent kinematic scattering simulations it is possible to translate the strain state into an In content.
Philippov, Sergey. "Modelagem computacional para a interpretação de dados de medição de tensões mecânicas pelo método de difração de raios X." Universidade do Estado do Rio de Janeiro, 2006. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=326.
Full textTensões mecânicas residuais próximas à superfície são importantes em relação às propriedades de materiais, como resistência, durabilidade, resistência a fricção etc. Muitos métodos modernos de tratamento de superfície produzem gradientes das tensões. Porém, até agora ainda não há um método de medição dos parâmetros destes gradientes, apesar de várias tentativas. A aplicação do método de difração de raios X ao problema é interessante pela possibilidade de avaliar os gradientes em camadas muito finas (~10m). Neste trabalho novos métodos como modelagem computacional, análise de Fourier e operação de convolução são aplicados à dados simulados que se obtêm pelo método de tensometria por raios X chamado método-sen2ψ. É mostrado que os gradientes de tensão produzem não-linearidades nas dependências experimentais e para gradientes fortes o suficiente estas não-linearidades podem ser registradas em experimento. São analisadas funções diferentes de distribuição de tensões e os efeitos que estas produzem para estados diferentes de tensões (uni-, bi- e tridimensional). É mostrado que a influência do gradiente pode ser descrita através da operação de convolução, e a função de gradiente pode ser obtida utilizando a transformada de Fourier e a operação de deconvolução. São estimados o menor valor de gradiente que pode ser registrado e a menor profundidade da distribuição não-homogênea de tensão que ainda tem efeito nos dados.
Residual stresses near the material surface are important for material's properties, like resistance, durability and friction resistance. A lot of modern methods of surface treatment produce stress gradients. However, up to now there is not a universal method of stress gradients parameters measurement, although various attempts were made. Aplication of X-ray diffraction method to the problem seems to be the best way to resolve it because of its possibility to measure the gradients in very thin layers (about 10m). Some new methods like computer simulation, Fourier analysis and operation of convolution are applied in this paper to simulate experimental data of X-ray tensometry method, called sin2ψ-method. It is shown that stress gradients produce non-linearities in the experimental dependences and for the gradients strong enough these non-linearities can be registered in experiment. There are analyzed different functions of stress distribution and the effects they produce for different stress states (one-, two- and three-dimensional). There is shown that the influence of gradient can be desribed by means of operation of convolution, and the gradient function can be found using Fourier transformation and deconvolution operation. It was estimated the smallest value of gradient that can be registered and the smallest depth of non-homogenious stress distribution that still has an effect on the data.
Ma, Jiajie. "Accuracy and reliability of non-linear finite element analysis for surgical simulation." University of Western Australia. School of Mechanical Engineering, 2006. http://theses.library.uwa.edu.au/adt-WU2010.0089.
Full textLübbert, Daniel. "Strain and lattice distortion in semiconductor structures : a synchrotron radiation study." Phd thesis, Universität Potsdam, 1999. http://opus.kobv.de/ubp/volltexte/2005/2/.
Full textIm ersten Teil der Arbeit werden Röntgen-Diffraktometrie und -Topographie zu einer Untersuchungsmethode kombiniert, mit der die makroskopische Krümmung von Halbleiter-Wafern ebenso wie ihre mikroskopische Defektstruktur abgebildet werden kann. Der zweite Teil ist der Untersuchung von epitaktisch gewachsenen und geätzten Oberflächengittern mit Abmessungen im Submikrometer-Bereich gewidmet. Die unterschiedlichen Gitterkonstanten der beteiligten Halbleitermaterialien führen zu einem inhomogenen Verzerrungsfeld in der Probe, das sich im Röntgenbild durch eine charakteristische Verformung des Beugungsmusters in der Umgebung der Bragg-Reflexe äussert. Die Analyse der experimentell gemessenen Beugungsmuster geschieht mit Hilfe eines neu entwickelten Simulationsverfahrens, das Elastizitätstheorie und eine semi-kinematische Röntgenbeugungstheorie miteinander verbindet. Durch quantitativen Vergleich der Simulationsergebnisse mit den Messdaten kann auf den genauen Verlauf des Verzerrungsfeldes in den Proben zurückgeschlossen werden. Dieses Verfahren wird erfolgreich auf verschiedene Halbleiter-Probensysteme angewendet, und schliesslich auch auf die Untersuchung von akustischen Oberflächenwellen in Halbleiterkristallen übertragen.
This thesis presents newly developed X-ray methods which can be used to characterize in detail the state of distortion of the crystal lattice in semiconductor wafers, devices and nanostructures. The methods use the extraordinary properties of the X-rays available from modern synchrotron sources such as the ESRF (Grenoble).
In the first part of the thesis, X-ray diffractometry and X-ray topography are combined into a new method, called X-ray rocking curve imaging, which allows to image the macroscopic curvature of semiconductor wafers as well as the underlying microscopic defect structure. The second part of the thesis deals with the investigation of epitaxially grown and subsequently etched semiconductor gratings with lateral periods below the micrometer. The lattice mismatch between the different materials used in heteroepitaxy leads to a non-uniform strain field in the sample, which is reflected in a characteristic distortion of the X-ray diffraction pattern around each Bragg peak. The experimental data are evaluated with the help of a newly developed simulation procedure which combines elasticity theory with a semi-kinematical theory of X-ray diffraction. From a quantitative comparison of measured and simulated data the detailed shape of the strain field in the samples can be deduced. This procedure is used successfully for the structural characterization of different types of semiconductor gratings, and is finally applied also to the investigation of surface acoustic waves in crystals.
Su, Ting. "Quantitative material decomposition methods for X-ray spectral CT." Thesis, Lyon, 2018. http://www.theses.fr/2018LYSEI056/document.
Full textX-ray computed tomography (X-ray CT) plays an important part in non-invasive imaging since its introduction. During the past few years, numerous technological advances in X-ray CT have been observed, including spectral CT, which uses photon counting detectors (PCDs) to discriminate transmitted photons corresponding to selected energy bins in order to obtain spectral information with one single acquisition. Spectral CT enables us to overcome many limitations of the conventional CT techniques and opens up many new application possibilities, among which quantitative material decomposition is the hottest topic. A number of material decomposition methods have been reported and different experimental systems are under development for spectral CT. According to the type of data on which the decomposition step operates, we have projection domain method (decomposition before reconstruction) and image domain method (decomposition after reconstruction). The commonly used decomposition is based on least square criterion, named proj-LS and ima-LS method. However, the inverse problem of material decomposition is usually ill-posed and the X-ray spectral CT measurements suffer from Poisson photon counting noise. The standard LS criterion can lead to overfitting to the noisy measurement data. In the present work, we have proposed a least log-squares criterion for projection domain method to minimize the errors on linear attenuation coefficient: proj-LLS method. Furthermore, to reduce the effect of noise and enforce smoothness, we have proposed to add a patchwise regularization term to penalize the sum of the square variations within each patch for both projection domain and image domain decomposition, named proj-PR-LLS and ima-PR-LS method. The performances of the different methods were evaluated by spectral CT simulation studies with specific phantoms for different applications: (1) Medical application: iodine and calcium identification. The decomposition results of the proposed methods show that calcium and iodine can be well separated and quantified from soft tissues. (2) Industrial application: ABS-flame retardants (FR) plastic sorting. Results show that 3 kinds of ABS materials with different flame retardants can be separated when the sample thickness is favorable. Meanwhile, we simulated spectral CT imaging with a PMMA phantom filled with Fe, Ca and K solutions. Different acquisition parameters, i.e. exposure factor and number of energy bins were simulated to investigate their influence on the performance of the proposed methods for iron determination
Renaud, Gilles. "Ordre chimique et désordre topologique dans les solutions solides AuNi : étude par résistivité et par absorption et diffusion du rayonnement synchrotron X." Grenoble 1, 1988. http://www.theses.fr/1988GRE10134.
Full textGolchert, Dennis J. "Application of X-ray microtomography to discrete element method simulations of agglomerate breakage /." St. Lucia, Qld, 2003. http://www.library.uq.edu.au/pdfserve.php?image=thesisabs/absthe17509.pdf.
Full textSilga, Matthias. "Elaboration de monocristaux de hgi::(2) alpha par la methode du flux force : application a la detection de rayonnements X gamma et alpha." Clermont-Ferrand 2, 1986. http://www.theses.fr/1986CLF21009.
Full textWang, Yongping. "Digital Simulative Test of Asphalt Mixtures Using Finite Element Method and X-Ray Tomography Images." Diss., Virginia Tech, 2007. http://hdl.handle.net/10919/28748.
Full textPh. D.
Ning, Jing. "Computer simulation for medical imaging with x-rays using the Monte Carlo methods." Thesis, University of Ulster, 2002. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.232847.
Full textCao, Weimin. "Theoretical and experimental studies of surface and interfacial phenomena involving steel surfaces." Doctoral thesis, KTH, Materialens processvetenskap, 2010. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-26194.
Full textQC 20101123
Moore, Zakhia. "Application of X-ray Diffraction Methods and Molecular Mechanics Simulations to Structure Determination and Cotton Fiber Analysis." ScholarWorks@UNO, 2008. http://scholarworks.uno.edu/td/888.
Full textJones, Cameron Christopher. "VALIDATION OF COMPUTATIONAL FLUID DYNAMIC SIMULATIONS OF MEMBRANE ARTIFICIAL LUNGS WITH X-RAY IMAGING." UKnowledge, 2012. http://uknowledge.uky.edu/cbme_etds/2.
Full textKulkarni, Kanchan Avinash. "Experimental Characterization and Finite Element Simulation of Laser Shock Peening Induced Surface Residual Stresses using Nanoindentation." University of Cincinnati / OhioLINK, 2012. http://rave.ohiolink.edu/etdc/view?acc_num=ucin1352489043.
Full textOhori, Shinya, and Kazuhiro Yamamoto. "Simulations on flow and soot deposition in diesel particulate filters." SAGE, 2013. http://hdl.handle.net/2237/20057.
Full textSokoltsova, Tetiana. "Development of a standardless miniature XRF setup for the analysis of actinides : coupling MC methods with fundamental parameters." Thesis, université Paris-Saclay, 2021. http://www.theses.fr/2021UPASP018.
Full textX-ray fluorescence (XRF) is qualitative and quantitative analytical tool for elemental analysis of many types of materials; it is non-destructive, fast and is suitable for the analysis of the wide range of elements. The method is based on the excitation of an analyte by a beam of primary X-rays to induce the emission of X-ray fluorescence from the sample. The goal of the quantitative XRF analysis is to relate the elemental concentrations to the measured fluorescence intensities. However, this task is not straightforward since the apparent fluorescence intensities are dependent on the weight fraction of an analyte, matrix composition, geometry of the experimental setup, parameters of the primary X-ray source and detection system, etc.. The quantitative information can be obtained applying theoretical or empirical approaches. One of the aims of this thesis is to investigate the performances of the miniaturised XRF setup intended to the analysis of actinides by their L X-ray lines (12 keV < E < 17 keV) installed in the analysis laboratory within ATALANTE facility (CEA Marcoule). The experimental setup includes an Ag-anode X-ray tube which irradiates a sample, a silicon drift detector (SDD) and a cylindrical HOPG monochromator. The latter element is positioned between the sample and the detection system and in such a geometry, it acts as a bandpass filter modifying the spectral distribution of the fluorescence radiation. In this manner, the spectra can be recorded in the energy range of interest reducing the burden on the detection system from an unwanted radiation. The HOPG monochromator of the experimental setup cover the energy range of interest and permits to analyse analysis of medium-Z (Se, Rb, Sr, Y, etc.) and high-Z (mainly U, Np, Pu, Am, and Cm) elements by their K and L X-ray lines, respectively. The second goal of this work is to refine the classical quantification algorithm based on the fundamental parameters taking into account the modifications of the spectral distribution by the HOPG crystal. Indeed, spectra measured with a classical XRF system can be successfully processed using a theoretical method based on mathematical equations without standards. Such method is called the fundamental parameters (FP) method. However, in order to process accurately the spectra measured with the present setup, it arises the necessity to know the transmission function of the HOPG filter. The detailed investigation of the miniature setup and of the physical phenomena involved was performed utilizing the Monte Carlo method for the radiation transport with the PENELOPE code. In addition, to establish a better understanding of the reflection properties of the HOPG crystal, ray-tracing simulations were performed using the dedicated the ray-tracing package XRT to model the cylindrical HOPG crystal and represent step by step the entire detection channel. The response of the developed optical system was simulated applying the experimental spectra recorded without the HOPG monochromator as an input data. The validity of the simulation model has been approved through the comparison with experimental data for different liquid samples containing medium-Z elements (a few tens of mg.L-1),what allowed to define the HOPG transfer function. Next, the estimated transfer function could be successfully applied in the FP-based software PyMCA to provide quantitative results. To conclude, it is demonstrated that the coupling of the PENELOPE Monte Carlo code and XRT simulations can be used to predict the spectral responses of the miniature setup under different geometrical conditions in order to help to improve it
Kalo, Kassem. "Caractérisation microstructurale et modélisation micromécanique de roches poreuses oolithiques." Thesis, Université de Lorraine, 2017. http://www.theses.fr/2017LORR0203/document.
Full textThe aim of this work is to study the influence of the microstructure of heterogeneous porous rocks on the behavior at the macroscopic scale. Thus, we characterized the microstructure and micromechanical properties (thanks to nano-indentation tests) of two porous oolitic rocks (Lavoux limestone and iron ore) to calculate their effective mechanical and thermal properties. Oolitic rocks are constituted by an assemblage of porous grains (oolites), pores and inter-granular crystals. Scanning electron microscopy and X-ray 3D Computed Tomography were used to identify the different components of these rocks. Particular attention was given to X-Ray computed tomography since this analytical method allows the characterization of the porous network (size, spatial distribution, and volume fraction), and the shapes of oolites and inter-oolitic crystals. The novelty of this work lies in taking into account the 3D real shape of pores. Hence, we approximated porous oolites by spheres and irregularly shaped pores by ellipsoids. This approximation was performed thanks to the principal component analysis (PCA), which provides the geometrical properties such as length of semi-axes and orientation of resulting ellipsoids. The sphericity of the approximated oolites was calculated and the values close to 1 allowed us to consider oolites as spheres. To verify the approximation in the case of pores, we evaluated the contribution of these irregularly shaped three-dimensional pores to the overall elastic properties. Thus, compliance contribution tensors for 3D irregular pores and their ellipsoidal approximations were calculated using the finite element method (FEM). These tensors were compared and a relative error was estimated to evaluate the accuracy of the approximation. This error produces a maximum discrepancy of 4.5% between the two solutions for pores and ellipsoids which verifies the proposed approximation procedure based on PCA. The FEM numerical method was verified by comparing the numerical solution for compliance contribution tensors of ellipsoids to the analytical solution based on Eshelby’s theory. The difference between these two solutions does not exceed 3%. The same numerical method was used to calculate thermal resistivity contribution tensors. Calculated compliance and resistivity contribution tensors were used to evaluate effective elastic properties (bulk modulus and shear coefficient) and effective thermal conductivity by considering the two-step Maxwell homogenization scheme. The results showed an important influence of the porosity on effective properties. Finally, the results obtained for irregular pores were compared to those for ellipsoidal ones and they showed a good agreement with a maximum deviation of 4% which verifies once again the approximation of irregularly shaped pores by tri-axial ellipsoids
Khalili, Mohamed Hassan. "Tracking and modelling small motions at grain scale in granular materials under compression by X-Ray microtomography and discrete simulations." Thesis, Paris Est, 2016. http://www.theses.fr/2016PESC1128/document.
Full textThe present work is motivated by the study of creep in granular materials at the microscopic scale.The first part of this thesis deals with displacement measurements by microtomography. Classical digital image correlation fails to catch time-dependent (possibly fast) phenomena such as short-term creep. A new method named emph{Discrete Digital Projection Correlation} is developed to overcome this limitation. This method requires very few projections (about 100 times less than classical methods) of the deformed state to perform the correlation and retrieve grain displacements. Therefore, the acquisition time is remarkably reduced, which allows to study time-dependent phenomena.The method is tested on experimental data. While its accuracy compares favorably to that of conventional methods, it only requires acquisition times of a few minutes. The origins of measurement errors are tracked by numerical means, on simulated grain displacements and rotations.The second part is a numerical simulation study, by the Discrete Element Method (DEM), of oedometric compression in model granular materials, carried out with a simple model material: assemblies of slightly polydisperse spherical beads interacting by Hertz-Mindlin contact elasticity and Coulomb friction. A wide variety of initial states are subject to compression, differing in density, coordination number and fabric anisotropy. Despite apparently almost reversible strains, oedometric compression proves an essentially anelastic and irreversible process,due to friction, with important internal state changes affecting coordination number and anisotropy. Elastic moduli only describe the response to very small stress increments about well equilibrated configurations. The ratio of horizontal stress to vertical stress (or coefficient of earth pressure at rest, commonly investigated in soil mechanics) only remains constant for initially anisotropic assemblies. A simple formula relates it to force and fabric anisotropy parameters, while elastic moduli are mainly sensitive to the latter. Further studies of contact network instabilities and rearrangements should pave the way to numerical investigations of creep behavior
Noel, Claire. "Hydrodynamical simulations of detonations in superbursts." Doctoral thesis, Universite Libre de Bruxelles, 2007. http://hdl.handle.net/2013/ULB-DIPOT:oai:dipot.ulb.ac.be:2013/210652.
Full textIn a firt step we obtain the detonation profiles in pure carbon and in a mixture of carbon and iron. In both cases we underline the large difference between the total reaction length and the length on which some species burn. This difference leads to enormous numerical difficulties because all the length scales cannot be resolved at the same time in a single simulation. We show that the carbon detonation might be studied in a partial resolution approach like the one of Gamezo & al. (1999).
In a second step we construct a new reduced nuclear reaction network able to reproduce the energy production due to the photo-disintegrations of heavy elements, like ruthenium, which are thought to occur during superbursts in mixed H/He accreting systems. Using this new nuclear network we simulate detonations in mixture of carbon and ruthenium. An interesting feature is that, in this case, all the reaction lengths can be resolved in the same simulation. This makes the C/Ru detonations easier to study in future multi-dimensional simulations than the pure carbon ones (Noel & al. 2007b).
Finally we perform some numerical experiments which show that our algorithm is able to deal with initially inhomogeneous medium, and that the multi-dimensional simulations are attainable even if they are quite computational time consuming.
- B. Van Leer, J. Comp. Phys. 21, 101, 1979
- Fryxell, B.A. Muller, E. and Arnett, W.D. Technical report MPA 449, 1989
- Busegnies, Y. Francois, J. and Paulus, G. Shock Waves, 11, 2007
- Gamezo, V.N. Wheeler, J.C. Khokhlov, A.M. and Oran, E.S. ApJ, 512, 827, 1999
- Noël, C. Busegnies, Y. Papalexandris, M.V. & al. A&A, 470, 653, 2007
- Noël, C. Goriely, S. Busegnies, Y. & Papalexandris, M.V. submitted to A&A, 2007b
/
Un algorithme parallèle basé sur une méthode aux volumes finis inspirée du schéma MUSCL de Van Leer (1979) a été construit. Il a été développé sur base de la méthode de Lappas & al. (1999) qui permet de résoudre simultanément toutes les dimensions spatiales. Cette méthode se base sur la construction de surfaces appropriées dans l'espace-temps, le long desquelles les équations de bilan se découplent en équations plus simples à intégrer. Cet algorithme est actuellement le seul à éviter le "splitting" des dimensions spatiales. Dans les modèles conventionnels (PPM, FCT, etc.), l'intégration spatiale des équations est réalisée de manière unidimensionnelle pour chaque direction.
Un réseau de réactions nucléaires ainsi qu'une équation d'état astrophysique ont été inclus dans l'algorithme et celui-ci a ensuite été soumis à une grande variété de cas tests réactifs et non réactifs. Il a été comparé à d'autres codes généralement utilisés en astrophysique (Fryxell & al. 1989, Fryxell & al. 2000, Busegnies & al. 2007) et il reproduit correctement leurs résultats. L'algorithme est décrit dans Noël & al. (2007).
Sur base de cet algorithme, les premières simulations de détonation dans des conditions thermodynamiques représentatives des Superbursts ont été réalisées. Différentes compositions du milieu ont été envisagées (carbone pur, mélange de carbone et de fer, mélange de carbone et de cendres du processus rp). Dans la plupart des systèmes où des Superbursts ont été observés, la matière accrétée est un mélange d'hydrogène et d'hélium. Dans ce cas, des phases de combustion précédant le Superburst produisent des nucléides plus lourd que le fer (Schatz & al. 2003). Ces nucléides peuvent être photodésintégrés durant le Superburst. Pour prendre en compte ces réactions endothermiques de photodésintégration, nous avons construit un nouveau réseau réduit de réactions nucléaires qui a été incorporé dans l'algorithme hydrodynamique (Noël & al. 2007b). Ce réseau réduit reproduit globalement l'énergétique d'un réseau complet et a permis de faire la première simulation numérique de détonation dans des conditions caractéristiques de systèmes accréteurs d'un mélange hydrogène-hélium.
Finallement quelques simulations multidimensionelles préliminaires ont éte réalisées.
- Busegnies, Y. Francois, J. and Paulus, G. Shock Waves, 11, 2007
- Fryxell, B.A. Muller, E. and Arnett, W.D. Technical report MPA 449, 1989
- Fryxell, B.A. Olson, K. Ricker, P. & al. ApJS, 131, 273, 2000
- Lappas, T. Leonard, A. and Dimotakis, P.E. SIAM J. Sci. Comput. 20, 1064, 1999
- Noël, C. Busegnies, Y. Papalexandris, M.V. & al. A&A, 470, 653, 2007
- Noël, C. Goriely, S. Busegnies, Y. & Papalexandris, M.V. submitted to A&A, 2007b
- Röpke, F. K. PhD thesis, Technischen Universitat Munchen, 2003
- Schatz, H. Bildsten, L. Cumming, A. and Ouellette, M. Nuclear Physics A, 718, 247, 2003
- Van Leer, B. Comp. Phys. 21, 101, 1979
- Weinberg, N.N. and Bildsten, L. ArXiv e-prints, 0706.3062, 2007
Doctorat en Sciences
info:eu-repo/semantics/nonPublished
Finke, Justin David. "Monte Carlo/Fokker-Planck simulations of Accretion Phenomena and Optical Spectra of BL Lacertae Objects." Ohio University / OhioLINK, 2007. http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1181833339.
Full textЛитвиненко, Д. О., and А. О. Ніколаєнко. "Інтерфейс програми для чисельного моделювання спектрів рентгенівської дифрації." Thesis, Сумський державний університет, 2014. http://essuir.sumdu.edu.ua/handle/123456789/38742.
Full textCavalcante, Fernanda Rocha. "Cálculo dos coeficientes de conversão de dose equivalente e dose efetiva em termos do kerma no ar para fótons utilizando simulador." Pós-Graduação em Física, 2013. https://ri.ufs.br/handle/riufs/5300.
Full textGrandezas dosimétricas são necessárias para avaliar exposições dos seres humanos à radiação de modo quantitativo e para descrever relações entre a dose e os efeitos biológicos causados pela interação da radiação com os órgãos e tecidos, fornecendo uma base para estimativas de riscos em proteção radiológica. No âmbito computacional, os simuladores antropomórficos são representações tridimensionais do corpo humano que quando acoplados a um código de transporte de radiação fornecem coeficientes de conversão para estimativa de dose equivalente e dose efetiva através de grandezas físicas, como por exemplo, o kerma no ar (Kar). Na literatura, os cenários de exposição são, em geral, formados por simuladores implementados na postura vertical (em pé). Neste trabalho, foram elaborados cenários de exposição no código Visual Monte Carlo utilizando um simulador voxel adulto feminino nas posturas vertical e sentada. O simulador foi irradiado por uma fonte plana de fótons monoenergéticos de 10 keV a 2 MeV nas geometrias de irradiação antero-posterior (AP), postero-anterior (PA), lateral direita (RLAT) e lateral esquerda (LLAT). Os coeficientes de conversão de dose equivalente e dose efetiva em termos do kerma no ar (HT/Kar e E/Kar ) foram calculados para ambos cenários e comparados. Os resultados mostram que a diferença relativa entre os coeficientes de conversão HT /Kar?? para os órgãos da cabeça e do tórax não foi significante (menor que 6%) devido à posição anatômica dos órgãos ser a mesma para ambas posturas. Entretanto, a diferença relativa é significante para órgãos da região abdominal inferior, como ovários (71% para fótons de 20 keV), bexiga (39% em 60 keV) e útero (37% em 100 keV), principalmente quando o simulador é irradiado na geometria AP. Nesta mesma geometria, os coeficientes de conversão E/Kar apresentaram diferenças mais evidentes (27% em 10 keV), devido uma mudança na dose absorvida de órgãos com fatores de ponderação teciduais (wT ) relevantes, situados na porção anterior do simulador. Assim, o cálculo dos coeficientes de conversão HT /Kar e E/Kar utilizando simuladores antropomórficos em diferentes posturas é importante para estimar mais precisamente a dose em indivíduos submetidos a cenários reais de exposição à radiação.
Maschio, Célio. "Desenvolvimento de metodos para avaliação de processos de filtração por meio de simulação por meio de simulação numerica e tomografia de raios-x." [s.n.], 2001. http://repositorio.unicamp.br/jspui/handle/REPOSIP/262896.
Full textTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica
Made available in DSpace on 2018-07-31T14:51:24Z (GMT). No. of bitstreams: 1 Maschio_Celio_D.pdf: 13410400 bytes, checksum: bcad1a44963fabb3c498533b4663302a (MD5) Previous issue date: 2001
Resumo: O objetivo deste trabalho foi o desenvolvimento de metodologias para o estudo de filtros e processos de filtração, utilizando a tomografia de raios-X, técnicas de processamento digital de imagens e simulação numérica. Os ensaios convencionais utilizados pelos fabricantes são realizados através da medida de parâmetros, tais como pressão e vazão, em pontos localizados a montante e a jusante do filtro. Estes ensaios não são eficientes na caracterização de defeitos e não revelam como ocorre o processo de saturação no interior do filtro. Neste trabalho, a tomografia de raios-X foi utilizada para duas finalidades básicas: estudar a distribuição de contaminantes e analisar defeitos no interior de elementos filtrantes. Os modelos de filtração encontrados na literatura não levam em conta o efeito do acúmulo de contaminantes no desempenho do filtro ao longo do processo de filtração. Neste trabalho, foi desenvolvido um modelo acoplando-se as equações de filtração com as equações fenomenológicas (lei de Darcy e equação da continuidade), de tal forma que o acúmulo de partículas no meio poroso (filtro) fosse considerado na simulação do processo de filtração. Os resultados demonstraram que o processo de saturação no interior dos elementos analisados não ocorre de forma homogênea, ou seja, o acúmulo de partículas é predominante em determinadas regiões. Em geral, há formação de canais preferenciais e o espaço interno do filtro não é totalmente utilizado na captura de partículas. Demonstrou-se também que, em alguns casos, o comportamento do filtro não é coerente com a especificação do fabricante. Foi possível, por fim, a utilização dos dados experimentais, obtidos via tomografia, para a validação do modelo teórico desenvolvido
Abstract: The development of methods for analysis of filters and filtration process, using X-ray computerized tomography, digital image processing and numerical simulation, was the objective of this work. Tests conventionally used by filter manufacturers are made through the measurement ofparameters, such as flow and pressure, at upstream and downstream ofthe filter. These tests are not efficient in the characterization of defects and do not reveal how the saturation process occurs within the filter. In this work, X-ray computerized tomography was used for two basic purposes: to evaluate contaminant distribution and to detect defects within the interior of the filter elements. The filtration models found in the literature do not consider the effect of contaminant concentration on the filter efficiency during the filtration processo In this work, filtration equations and phenomenological equations (Darcy's law and continuity equation) were coupled and a model that takes into account the contaminant accumulation on the filter performance was developed. The results demonstrated that the saturation process within the analyzed filters is not homogeneous, that is, the accumulation of partic1es is predominant in some regions. Generally, there are preferential channels and the interior of the filter elements is not totally utilized. In some cases, it was also demonstrated that the filter behavior does not agree with the manufacturer specifications. Finally, it was possible to use the experimental data obtained with X-ray computerized tomography, in order to validate the theoretical developed model
Doutorado
Materiais e Processos de Fabricação
Doutor em Engenharia Mecânica
Cozer, Thamara Cristina. "Análise de elementos traço presentes em tecidos mamários canino através da técnica de fluorescência de raios X." Universidade Tecnológica Federal do Paraná, 2016. http://repositorio.utfpr.edu.br/jspui/handle/1/1842.
Full textEstudos realizados com cães apontam que dos grupos tumorais analisados, os de mama representam cerca de 25% a 50% dos tipos de tumores. Deste total, metade é considerado maligno. Apesar de representar um valor considerável de malignidade, estudos nesta área são poucos representativos e escassos na literatura. É de conhecimento que os tumores são causados por mudanças químicas e bioquímicas que ocorrem na célula. Atualmente, pesquisas são realizadas para entender o comportamento dessas alterações e por este motivo é de grande valia conhecer os elementos traço presentes nestes tecidos. Para esta finalidade a técnica mais empregada é a de ED-XRF (Fluorescência de Raios X de Dispersão de Energia), uma vez que é uma técnica analítica não destrutiva que permite determinar e quantificar a composição elementar das amostras, porém não identifica elementos com baixos números atômicos (menor que Z=10). Foram analisadas 56 amostras de tecido mamário canino benignas e malignas, fixadas em formalina a 10% tamponada e mantida à temperatura ambiente. Primeiramente para a quantificação dos elementos traço Ca, Fe, Cu e Zn foram determinadas as curvas de calibração de padrões diluídos em água, com concentrações de Ca, Fe, Cu e Zn, variando de 400 mg/kg a 35 mg/kg, de 20 mg/kg a 2 mg/kg, de 10 mg/kg a 1 mg/kg e de 100 mg/kg a 9 mg/kg, respectivamente. As medições foram submetidas à técnica de ED-XRF utilizando um tubo de raios X com ânodo de prata e técnica de exposição de 30 kV e 100uA e um tempo de exposição de 1000 segundos (incerteza ≤ 3%). O código XRMC (X-Ray Monte Carlo) foi utilizado para validação do método experimental, que tem o objetivo de simular computacionalmente as respostas esperadas para os ensaios experimentais validando assim a eficácia da metodologia. As concentrações dos elementos traço obtidas foram analisadas estatisticamente onde verificou-se uma variação significativa do elemento Zn, estando este presente em maior concentração no tecido mamário maligno do que no benigno. Este resultado pode estar relacionado à presença deste elemento nas matrizes de metaloproteinases, e em neoplasias malignas estão mais concentradas porque há característica de invasão tumoral neste tipo de neoplasia. Em outra comparação estatística pode-se verificar que os elementos traços Fe, Cu e Zn tem concentração equivalente tanto na região central do tumor tanto quanto na periferia, com exceção do Ca, este concentrando-se mais na região tumoral o que pode se dever às calcificações. Estudos nessa área são de grande potencial por permitir um melhor entendimento do processo patológico em tumores mamários caninos.
Studies with dogs show that the breast cancer represent about 25% to 50% of tumor types. Of this total, half is considered malignant. Despite representing a considerable amount of malignancy, studies in this area are few representative and scarce in the literature. It is known that tumors are caused by chemical and biochemical changes that occur in the cell. Currently, surveys are conducted to understand the behavior of these changes and for this reason, it is of great value to know the trace elements present in these tissues. For this purpose, the most common technique is to ED-XRF (X-Ray Fluorescence Energy Dispersion) since it is a non-destructive analytical technique to determine and quantify the elemental composition of the samples, although it doesn’t identify elements with low atomic numbers (less than Z= 10). Were analyzed 56 samples of canine breast tissue benign and malignant, fixed in 10% buffered formalin and kept at ambient temperature. First, for the measurement of trace elements Ca, Fe, Cu and Zn were determined standards for calibration curves diluted in water to concentrations of Ca, Fe, Cu and Zn, ranging from 400 mg/kg to 35 mg/kg, from 20 mg/kg to 2 mg/kg, from 10 mg/kg to 1 mg/kg and from 100 mg/kg to 9 mg/kg, respectively. Measurements were subjected to ED-XRF technique using an X-ray tube with silver anode and exposure technique of 30 kV and 100 uA and exposure time of 1000 seconds (uncertainty ≤ 3%). The XRMC code (X-Ray Monte Carlo) was used for validation of experimental method, which is intended to simulate by computer the expected responses for experimental tests, therefore validating the methodology efficiency. The concentrations of trace elements obtained were analyzed statistically where there was a significant variation of Zn element, the latter being present in higher concentration in malignant breast tissue than benign. This result may be related to the presence of this element in the matrix metalloproteinases, and malignant neoplasms are more concentrated because there are characteristic of tumor invasion in this type of neoplasm. In another statistical comparison it can be seen that the trace elements Fe, Cu and Zn is equivalent concentration both in the central region of the tumor as well as in the periphery, with the exception of Ca, this focusing more on the tumor region may be due to calcifications. Studies in this area are of great potential for allowing a better understanding of the disease process in canine mammary tumors.
Cedola, Alessia. "Production de faisceaux de rayons-X submicroniques par guide d'onde en couches minces." Université Joseph Fourier (Grenoble ; 1971-2015), 1999. http://www.theses.fr/1999GRE10040.
Full textIglesias, Susana Marrero. "Simulação e análise de gradientes de tensão em materiais e ligas metálicas." Universidade do Estado do Rio de Janeiro, 2008. http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=788.
Full textThe residual stress influences the mechanical behavior of metals and alloys. The stress field can determine the material performance. Then, become of great importance the study and determination of residual stress field. The standard X-ray diffraction method for residual stress measurement ent ( sen2ψ Method) presents limitations in the strong stress gradient determination. For that reason, the superficial stress gradient determination is one of the most important theoretical and experimental problem in engineering, especially in the analysis of the stress gradients due to surfaces treatments as laser or ionic implantation. The computational simulation and numerical methods give us the possibility of solve this problems. In this work is developed and applied two methods of modeling and simulation for the study of the material behavior with strong stress gradient. Is applied this modeling technique for different stress distribution in pure metals and metallic alloys. Is established a methodology for the composite material cases and is presents the results for the case of siluminium, showing that the behavior is similar to the other metals testing as steel and aluminum. Also, using Fourier analysis is determined the distortion function for the broadened profiles in the presence of stress gradient. In this work is shown the relation between the attenuation and stress distribution functions in the distortion. Is shown, results for several stress distribution functions. Moreover, is developed a methodology for the determination of stress gradient parameters using the computational simulation of the diffraction lines also developed in this work. The methodology is based in the simulation of the profiles broadened by stress gradient and the analysis of these distortions. Of the developed methodologies for the determination of stress distribution functions for the gradient case, the one that uses Fourier analysis is mathematically correct, but presents difficulties in the determination of the gradient functions for cases of complex stress distributions and in the scales determination of the functions involved in the deconvolution process. The high complexity of this method and the numeric problems that it carries leaves as, to propose the use of the developed methodology using the integral breath of the diffraction profiles for the approximate determination of the stress distribution function. The methodology application is simple and its accuracy will depend on the amount of data determined in the direct simulation to obtain the calibration graphics.
Zeiske, Tim. "Understanding complex biomolecular systems through the synergy of molecular dynamics simulations, NMR spectroscopy and X-Ray crystallography." Thesis, 2016. https://doi.org/10.7916/D8TX3F60.
Full textBootsma, Gregory James. "Physics and Computational Methods for X-ray Scatter Estimation and Correction in Cone-beam Computed Tomography." Thesis, 2013. http://hdl.handle.net/1807/65456.
Full text"Automatic extraction of bronchus and centerline determination from CT images for three dimensional virtual bronchoscopy." 2000. http://library.cuhk.edu.hk/record=b5890498.
Full textThesis (M.Phil.)--Chinese University of Hong Kong, 2000.
Includes bibliographical references (leaves 64-70).
Abstracts in English and Chinese.
Acknowledgments --- p.ii
Chapter 1 --- Introduction --- p.1
Chapter 1.1 --- Structure of Bronchus --- p.3
Chapter 1.2 --- Existing Systems --- p.4
Chapter 1.2.1 --- Virtual Endoscope System (VES) --- p.4
Chapter 1.2.2 --- Virtual Reality Surgical Simulator --- p.4
Chapter 1.2.3 --- Automated Virtual Colonoscopy (AVC) --- p.5
Chapter 1.2.4 --- QUICKSEE --- p.5
Chapter 1.3 --- Organization of Thesis --- p.6
Chapter 2 --- Three Dimensional Visualization in Medicine --- p.7
Chapter 2.1 --- Acquisition --- p.8
Chapter 2.1.1 --- Computed Tomography --- p.8
Chapter 2.2 --- Resampling --- p.9
Chapter 2.3 --- Segmentation and Classification --- p.9
Chapter 2.3.1 --- Segmentation by Thresholding --- p.10
Chapter 2.3.2 --- Segmentation by Texture Analysis --- p.10
Chapter 2.3.3 --- Segmentation by Region Growing --- p.10
Chapter 2.3.4 --- Segmentation by Edge Detection --- p.11
Chapter 2.4 --- Rendering --- p.12
Chapter 2.5 --- Display --- p.13
Chapter 2.6 --- Hazards of Visualization --- p.13
Chapter 2.6.1 --- Adding Visual Richness and Obscuring Important Detail --- p.14
Chapter 2.6.2 --- Enhancing Details Incorrectly --- p.14
Chapter 2.6.3 --- The Picture is not the Patient --- p.14
Chapter 2.6.4 --- Pictures-'R'-Us --- p.14
Chapter 3 --- Overview of Advanced Segmentation Methodologies --- p.15
Chapter 3.1 --- Mathematical Morphology --- p.15
Chapter 3.2 --- Recursive Region Search --- p.16
Chapter 3.3 --- Active Region Models --- p.17
Chapter 4 --- Overview of Centerline Methodologies --- p.18
Chapter 4.1 --- Thinning Approach --- p.18
Chapter 4.2 --- Volume Growing Approach --- p.21
Chapter 4.3 --- Combination of Mathematical Morphology and Region Growing Schemes --- p.22
Chapter 4.4 --- Simultaneous Borders Identification Approach --- p.23
Chapter 4.5 --- Tracking Approach --- p.24
Chapter 4.6 --- Distance Transform Approach --- p.25
Chapter 5 --- Automated Extraction of Bronchus Area --- p.27
Chapter 5.1 --- Basic Idea --- p.27
Chapter 5.2 --- Outline of the Automated Extraction Algorithm --- p.28
Chapter 5.2.1 --- Selection of a Start Point --- p.28
Chapter 5.2.2 --- Three Dimensional Region Growing Method --- p.29
Chapter 5.2.3 --- Optimization of the Threshold Value --- p.29
Chapter 5.3 --- Retrieval of Start Point Algorithm Using Genetic Algorithm --- p.29
Chapter 5.3.1 --- Introduction to Genetic Algorithm --- p.30
Chapter 5.3.2 --- Problem Modeling --- p.31
Chapter 5.3.3 --- Algorithm for Determining a Start Point --- p.33
Chapter 5.3.4 --- Genetic Operators --- p.33
Chapter 5.4 --- Three Dimensional Painting Algorithm --- p.34
Chapter 5.4.1 --- Outline of the Three Dimensional Painting Algorithm --- p.34
Chapter 5.5 --- Optimization of the Threshold Value --- p.36
Chapter 6 --- Automatic Centerline Determination Algorithm --- p.38
Chapter 6.1 --- Distance Transformations --- p.38
Chapter 6.2 --- End Points Retrieval --- p.41
Chapter 6.3 --- Graph Based Centerline Algorithm --- p.44
Chapter 7 --- Experiments and Discussion --- p.48
Chapter 7.1 --- Experiment of Automated Determination of Bronchus Algorithm --- p.48
Chapter 7.2 --- Experiment of Automatic Centerline Determination Algorithm --- p.54
Chapter 8 --- Conclusion --- p.62
Bibliography --- p.63