Academic literature on the topic 'Flowmeter'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Flowmeter.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Flowmeter"

1

Ben Salamah, Mohammad J., and Mehmet Savsar. "Analyzing and Detecting Drifts in a Flowmeter by Discrete Fourier Transform." Mathematical Modelling of Engineering Problems 8, no. 4 (2021): 519–26. http://dx.doi.org/10.18280/mmep.080404.

Full text
Abstract:
Large flowmeters are used in many industrial facilities, including power plants, cooling-water stations for refineries, and petrochemical plants. These flowmeters are employed for various purposes, including billing. Just like all machines, flowmeters are subject to failure. Drift is a particular type of failure in which the flowmeter produces an error in measurement that would incrementally increase with time. Maintenance technicians calibrate and fix all measuring equipment, including flowmeters. Nevertheless, downsizing policies and budget cuts in most contemporary industrial facilities hav
APA, Harvard, Vancouver, ISO, and other styles
2

Szudarek, Maciej, Mateusz Turkowski, and Adam Piechna. "CFD Model of a Mechanical Oscillator Flowmeter." Sensors 23, no. 1 (2022): 116. http://dx.doi.org/10.3390/s23010116.

Full text
Abstract:
Most of the studies on mechanical oscillator flowmeters were conducted in the ‘80s and ‘90s when computational fluid dynamics (CFD) was not a viable scientific tool in flow metrology. Still, many topics related to the application of mechanical oscillator flowmeters require further investigation. In the article, a numerical model of a mechanical oscillator flowmeter is developed with the commercial software ANSYS Fluent. The model is validated against experimental data obtained at a water calibration stand. The influence of the selected turbulence model, dynamic mesh method, as well as grid and
APA, Harvard, Vancouver, ISO, and other styles
3

Hou, Qing Qiang, Yong Mei Huang, Zhi Liang Zhang, and Bin Sun. "Automatic Calibration of Clamp-On Ultrasonic Flowmeter Based on Fieldbus Control System." Advanced Materials Research 301-303 (July 2011): 1730–34. http://dx.doi.org/10.4028/www.scientific.net/amr.301-303.1730.

Full text
Abstract:
In practical application, some flowmeters are not allowed to be calibrated off-line periodically, thus on-line calibration is necessary to be implemented in workplace [1]. As a non-invasive flowmeter, the clamp-on ultrasonic flowmeters are widely used in on-line calibration system. As a master flowmeter, ultrasonic flowmeters must be calibrated before or during using. Based on multiple fieldbus control system, an automatic calibration system for the ultrasonic flowmeter was designed. The comparison results between ultrasonic and electromagnetic flowmeter obtained during the process of calibrat
APA, Harvard, Vancouver, ISO, and other styles
4

MacLeod, J. D., and W. Grabe. "Comparison of Coriolis and Turbine-Type Flowmeters for Fuel Measurement in Gas Turbine Testing." Journal of Engineering for Gas Turbines and Power 117, no. 1 (1995): 132–37. http://dx.doi.org/10.1115/1.2812761.

Full text
Abstract:
The Machinery and Engine Technology (MET) Program of the National Research Council of Canada (NRCC) has established a program for the evaluation of sensors to measure gas turbine engine performance accurately. The precise measurement of fuel flow is an essential part of steady-state gas turbine performance assessment. Prompted by an international engine testing and information exchange program, and a mandate to improve all aspects of gas turbine performance evaluation, the MET Laboratory has critically examined two types of fuel flowmeters, Coriolis and turbine. The two flowmeter types are dif
APA, Harvard, Vancouver, ISO, and other styles
5

Sun, Zhiqiang. "Design and Performance of the Converging-Diverging Vortex Flowmeter." Metrology and Measurement Systems 18, no. 1 (2011): 129–36. http://dx.doi.org/10.2478/v10178-011-0012-5.

Full text
Abstract:
Design and Performance of the Converging-Diverging Vortex Flowmeter The converging-diverging structure is introduced to extend the lower limit of measurement of vortex flowmeters. As a compact device, the converging-diverging vortex flowmeter is proposed and designed, and its performance is studied experimentally. It is found that, first of all, an up to 51% extension of the lower measurement limit can be realized through the converging-diverging structure, compared with conventional vortex flowmeters; second, the converging-diverging vortex flowmeter with a trapezoidal bluff body has a larger
APA, Harvard, Vancouver, ISO, and other styles
6

Lian, Mingming, Jin Zheng, Zhen Li, Dongkui Huang, Qingfeng Xue, and Zhaoming Zhou. "Numeerical Calculation and Test of the Influence of Environmental Vibration on Coriolis Flowmeter." Journal of Physics: Conference Series 2503, no. 1 (2023): 012080. http://dx.doi.org/10.1088/1742-6596/2503/1/012080.

Full text
Abstract:
Abstract Coriolis mass flowmeters are resonant meters. In this paper, the intrinsic mode of the CMF300 model Coriolis flowmeter under fluid-structure interaction is calculated numerically, and the excitation mode and Coriolis force mode of the Coriolis mass flowmeter in the working state are analyzed. According to the results of modal analysis, the harmonic response analysis of the flowmeter was carried out, and the displacement, stress, and strain response curves of CMF300 under the action of excitation force of different frequency loads were obtained. It provides ideas for the modeling and d
APA, Harvard, Vancouver, ISO, and other styles
7

Ekejiuba, A.I.B., S.I. Onwukwe, and E.T. Gbaden. "Cost-Benefit Approach to Replacing Conventional Test Separators with Multiphase Flowmeters in Today's Well Performance Monitoring." European Journal of Advances in Engineering and Technology 7, no. 9 (2020): 1–4. https://doi.org/10.5281/zenodo.10667850.

Full text
Abstract:
<strong>ABSTRACT</strong> In spite of advances in multiphase flowmeter technology since inception, test separators continue to hold relevance in well performance monitoring around the globe. This paper investigated the economic viability of replacing existing test separators with multiphase flowmeters in today's well performance monitoring using a cost-benefit approach for supporting management decision-making process. Data analysis using cost-benefit approach indicates that given the current procurement and installation cost for multiphase flowmeters, it is not economically viable to replace
APA, Harvard, Vancouver, ISO, and other styles
8

Pereguda, Arkady I. "Reliability of the RBMK-1000 coolant flow measurement system." Nuclear Energy and Technology 5, no. 1 (2019): 81–87. http://dx.doi.org/10.3897/nucet.5.34296.

Full text
Abstract:
An analysis of statistical data of diagnostic measurements of two parameters determining the performance of the RBMK-1000 SHADR-8A flowmeters – the minimum value of the negative amplitude half-wave at the transistor flow measuring unit (TIBR) input and the mean-square deviation over the flowmeter ball rotation period – made it possible to develop a mathematical model of the flowmeter parametric reliability. This mathematical model is a random process, which is a superposition of two delayed renewal processes. Studying the flowmeter operational reliability model provides an exponential estimate
APA, Harvard, Vancouver, ISO, and other styles
9

Pereguda, Arkady I. "Reliability of the RBMK-1000 coolant flow measurement system." Nuclear Energy and Technology 5, no. (1) (2019): 81–87. https://doi.org/10.3897/nucet.5.34296.

Full text
Abstract:
An analysis of statistical data of diagnostic measurements of two parameters determining the performance of the RBMK-1000 SHADR-8A flowmeters – the minimum value of the negative amplitude half-wave at the transistor flow measuring unit (TIBR) input and the mean-square deviation over the flowmeter ball rotation period – made it possible to develop a mathematical model of the flowmeter parametric reliability. This mathematical model is a random process, which is a superposition of two delayed renewal processes. Studying the flowmeter operational reliability model provides an exponential estimate
APA, Harvard, Vancouver, ISO, and other styles
10

Zhang, Xiaoxiao. "P‐8.5: Research on Flowmeter Signal Processing Method Based on Improved Kalman Filterust." SID Symposium Digest of Technical Papers 55, S1 (2024): 1142–44. http://dx.doi.org/10.1002/sdtp.17304.

Full text
Abstract:
Flowmeter is an instrument for measuring the flow rate of fluid, which is widely used in industrial, agricultural, environmental and other fields. However, the signal of flowmeter is often affected by various noises and interferences, which reduces the measurement accuracy. In order to improve the signal quality of flowmeter, this paper proposes a flowmeter signal processing method based on adaptive Kalman filter. This method uses the advantages of Kalman filter, combined with adaptive algorithm, dynamically adjusts the process noise covariance matrix and measurement noise covariance matrix, a
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Flowmeter"

1

Du, Preez M., and P. Hertzog. "Ultrasonic borehole flowmeter." Interim : Interdisciplinary Journal, Vol 7, Issue 1: Central University of Technology Free State Bloemfontein, 2008. http://hdl.handle.net/11462/378.

Full text
Abstract:
Published Article<br>Although research has been conducted in the field of Acoustic Doppler Borehole Flowmeters (ADBF), it has been focused on point source of flow and three dimensional borehole flow techniques. However as of yet, no studies have been conducted on the possible use of Acoustic Doppler Borehole Profiling (ADBP). This technique of borehole flow measurement is possibly a revolutionary concept in how vertical flow in a borehole is measured. It makes use of a single inexpensive transducer that can float on the surface of the water in a borehole and use Acoustic Doppler techniques to
APA, Harvard, Vancouver, ISO, and other styles
2

Ajayi, A. A. "Turbine flowmeter signal analysis." Thesis, University of Bradford, 1988. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.381420.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Amare, T. "Electromagnetic flowmeter for dielectric liquids." Thesis, Cranfield University, 1995. http://dspace.lib.cranfield.ac.uk/handle/1826/7116.

Full text
Abstract:
Experimental investigation and theoretical analysis of an electromagnetic flowmeter designed for use with dielectric liquids has been carried out. An extensive survey of the industrial users of flowmeters has been made, involving the participation of over 47 companies, which provides information about the current industrial use, attitudes and attributes of electromagnetic and other types of flowmeters. The design of the flowmeter is mainly concerned with overcoming the charge noise that is associated with the flow of dielectric liquids so as to effectively detect the weak flow signal. It is sh
APA, Harvard, Vancouver, ISO, and other styles
4

Somabha, Chalum. "Analysis of ultrasonic flowmeter output signals." Thesis, University of Liverpool, 2002. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.399270.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Le, Nam Tuan Phuong. "Modelling of calibration steam flowmeter test bench." Mémoire, Montréal : École de technologie supérieure, 2004. http://wwwlib.umi.com/cr/etsmtl/fullcit?pMQ86831.

Full text
Abstract:
Thèse (M. Ing.)--École de technologie supérieure, Montréal, 2004.<br>"Thesis submitted to École de technologie supérieure in fulfillment of the requirements for the degree of master in engineering mechanics". Bibliogr.: f. [78]-[79]. Également disponible en version électronique.
APA, Harvard, Vancouver, ISO, and other styles
6

Scanlon, Thomas J. "Vortex shedding flowmeter pulsating flow CFD studies." Thesis, University of Strathclyde, 1992. http://oleg.lib.strath.ac.uk:80/R/?func=dbin-jump-full&object_id=21339.

Full text
Abstract:
The computational analysis of vortex shedding flow is presented, using the commercially available computational fluid dynamics(CFD) software package PHOENICS. In this analysis it is shown how the use of the conventional PHOENICS default first-order hybrid-upwind convective differencing scheme provides an excellent example of the effects of multidimensional false diffusion. These effects are substantially reduced with the introduction of an alternative scheme, SUCCA ( Skew Upwind Corner Convection Algorithm), for the modelling of convective transport in 2D and 3D analyses; resulting in the prom
APA, Harvard, Vancouver, ISO, and other styles
7

Ferreira, V. C. S. "Flow patterns inside a turbine type flowmeter." Thesis, Cranfield University, 1988. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.380749.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Townsend, Russell James. "Experimental study of a scanning laser doppler flowmeter." University of Western Australia. Centre for Ophthalmology and Visual Science, 2005. http://theses.library.uwa.edu.au/adt-WU2005.0063.

Full text
Abstract:
[Truncated abstract] Purpose: To improve our ability to interpret and validate Heidelberg Retina Flowmeter (HRF) flow images by recording flow measurements from specific regions of the retinal vasculature in in-vitro and in-vivo eye models in which retinal blood flow can be manipulated. Methods: The first experiments utilised an isolated perfused pig eyes perfused with a 50%/50% Krebs/RBC solution at known flow rates ranging from zero to 300 μl/min. After HRF image acquisition, the retinal vasculature was perfused with fluorescein isothiocyanate (FITC), for fluorescence microscopy. Using the s
APA, Harvard, Vancouver, ISO, and other styles
9

Ghaoud, Tarek. "Improvements to signal processing for a vortex flowmeter." Thesis, University of Oxford, 2001. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.393753.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Ayatollahi, Ahmad. "A three channel pulsed doppler skin blood flowmeter." Thesis, University of Manchester, 1989. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.260814.

Full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Flowmeter"

1

United States. National Aeronautics and Space Administration., ed. Flowmeter evaluation for on-orbit operations. National Aeronautics and Space Administration, 1988.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Yeh, T. T. Flowmeter installation effects due to a generic header. U.S. Dept. of Commerce, Technology Administration, National Institute of Standards and Technology, 1996.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

C, Young Steven, and National Risk Management Research Laboratory (U.S.), eds. Application of the electromagnetic borehole flowmeter: Project summary. U.S. Environmental Protection Agency, National Risk Management Research Laboratory, 1998.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

A, Lewis M., and National Institute of Standards and Technology (U.S.), eds. Flow conditioner tests for three orifice flowmeter sizes. U.S. Dept. of Commerce, Technology Administration, National Institute of Standards and Technology, 1994.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Johnson, Aaron N. Gas flowmeter calibrations with the 26 m³ PVTt standard. U.S. Dept. of Commerce, Technology Administration, National Institute of Standards and Technology, 2011.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

Calla, Domenic. An ultrasound transducer for use in a doppler catheter flowmeter. National Library of Canada, 1995.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

American Society of Heating, Refrigerating and Air-Conditioning Engineers. Flowmeter test methods for mass flow measurement of volatile refrigerants. American Society of Heating, Refrigerating and Air-Conditioning Engineers, 2003.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

Deng, Tong. Simulation study of an ultrasonic transit time flowmeter based on Golay codes. UMIST, 1997.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

National Institute of Standards and Technology (U.S.), ed. Gas flowmeter calibrations with the 34 L and 677 L PVTt standards. U.S. Dept. of Commerce, National Institute of Standards and Technology, 2004.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

Yeh, T. T. Summary report of NIST's industry-government consortium research program on flowmeter installation effects: the 45 degree elbow. U.S. Dept. of Commerce, Technology Administration, National Institute of Standards and Technology, 1994.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Flowmeter"

1

Nilsson, Gert E. "Perimed’s LDV Flowmeter." In Laser-Doppler Blood Flowmetry. Springer US, 1990. http://dx.doi.org/10.1007/978-1-4757-2083-9_4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Holloway, G. Allen. "Medpacific’s LDV Blood Flowmeter." In Laser-Doppler Blood Flowmetry. Springer US, 1990. http://dx.doi.org/10.1007/978-1-4757-2083-9_3.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Borgos, John A. "TSI’s LDV Blood Flowmeter." In Laser-Doppler Blood Flowmetry. Springer US, 1990. http://dx.doi.org/10.1007/978-1-4757-2083-9_5.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Sampaolesi, Roberto, Juan Roberto Sampaolesi, and Jorge Zárate. "Heidelberg Retina Flowmeter (HRF)." In The Glaucomas. Springer Berlin Heidelberg, 2013. http://dx.doi.org/10.1007/978-3-642-35500-4_26.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Gu, Chen, Guozeng Feng, and Yuejiao Guo. "Experimental research on performance of a novel differential pressure flowmeter: Olive-shaped flowmeter (OSF)." In Advances in Measurement Technology, Disaster Prevention and Mitigation. CRC Press, 2022. http://dx.doi.org/10.1201/9781003330172-10.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Bertacchini, Alessandro, and Paolo Pavan. "An Ultra-Low Cost Triboelectric Flowmeter." In Lecture Notes in Electrical Engineering. Springer International Publishing, 2019. http://dx.doi.org/10.1007/978-3-030-11973-7_14.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Norgia, M., A. Pesatori, and L. Rovati. "Optical Flowmeter Sensor for Blood Circulators." In Lecture Notes in Electrical Engineering. Springer Netherlands, 2009. http://dx.doi.org/10.1007/978-90-481-3606-3_15.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Amadi-Echendu, J. E., E. H. Higham, and P. J. Hurren. "Plant Health Monitoring Using a Turbine Flowmeter." In COMADEM 89 International. Springer US, 1989. http://dx.doi.org/10.1007/978-1-4684-8905-7_25.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Lévesque, J. M., J. Néron, and C. M. Tran. "18-Paths Acoustic Flowmeter and Transducer Protrusion." In Hydraulic Machinery and Cavitation. Springer Netherlands, 1996. http://dx.doi.org/10.1007/978-94-010-9385-9_115.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Ding, Shoucheng, Limei Xiao, and Guici Yuan. "A Time Difference Method Pipeline Ultrasonic Flowmeter." In Lecture Notes in Electrical Engineering. Springer Berlin Heidelberg, 2011. http://dx.doi.org/10.1007/978-3-642-21697-8_60.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Flowmeter"

1

Wang, Zhe, Yiming Shen, Zhuochen Wang, et al. "Microfluidic flowmeter using a PDMS-coated capillary." In 29th International Conference on Optical Fiber Sensors, edited by Manuel Lopez-Amo Sainz, José Luís Santos, and Tong Sun. SPIE, 2025. https://doi.org/10.1117/12.3062293.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

MacLeod, J. D., and W. Grabe. "Comparison of Coriolis and Turbine Type Flow Meters for Fuel Measurement in Gas Turbine Testing." In ASME 1993 International Gas Turbine and Aeroengine Congress and Exposition. American Society of Mechanical Engineers, 1993. http://dx.doi.org/10.1115/93-gt-070.

Full text
Abstract:
The Machinery and Engine Technology (MET) Program of the National Research Council of Canada (NRCC) has established a program for the evaluation of sensors to measure gas turbine engine performance accurately. The precise measurement of fuel flow is an essential part of steady-state gas turbine performance assessment. Prompted by an international engine testing and information exchange program, and a mandate to improve all aspects of gas turbine performance evaluation, the MET Laboratory has critically examined two types of fuel flowmeters, Coriolis and turbine. The two flowmeter types are dif
APA, Harvard, Vancouver, ISO, and other styles
3

Liu, Xin, Xiangyu Yun, Junming Liang, and HuiYong Zhang. "Experimental Study on Measurement Characteristics of Different Type Flow Meters in Pb-Bi Environment." In 2022 29th International Conference on Nuclear Engineering. American Society of Mechanical Engineers, 2022. http://dx.doi.org/10.1115/icone29-91675.

Full text
Abstract:
Abstract Lead bismuth eutectic is one of the most promising materials for coolant of fourth-generation reactor due to its outstanding heat transfer performance and chemical stability. However, the density and viscosity of lead bismuth eutectic is quite different from water, leading to a difficulty for flow measurement because of the high temperature operating environment and its strongly corrosive. Therefore, there is currently not a reliable flowmeter for measuring the volume flow of the lead bismuth eutectic. Electromagnetic flow meter has the advantage for measuring lead bismuth eutectic fl
APA, Harvard, Vancouver, ISO, and other styles
4

Gryshanova, Iryna, and Ivan Korobko. "Research on Developing Propeller Flowmeters With Increased Accuracy." In ASME 2004 Heat Transfer/Fluids Engineering Summer Conference. ASMEDC, 2004. http://dx.doi.org/10.1115/ht-fed2004-56805.

Full text
Abstract:
This research is devoted to an increase in the accuracy of propeller flowmeters. Achievement of this goal solved a number of problems. These include the following: • development of a detailed multi-parametrical mathematical model that considers many influences; • investigation of propeller flowmeter behavior in the dynamic mode at propeller acceleration from the condition of rest and its sudden retardation; • study of propeller flowmeters in the static mode. The analysis of the influence of physical properties of measured liquids and flowmeter geometrical parameters on the static characteristi
APA, Harvard, Vancouver, ISO, and other styles
5

Owen, I., I. Fyrippi, and M. P. Escudier. "Flowmetering of Shear-Thinning Non-Newtonian Liquids (Keynote)." In ASME/JSME 2003 4th Joint Fluids Summer Engineering Conference. ASMEDC, 2003. http://dx.doi.org/10.1115/fedsm2003-45588.

Full text
Abstract:
This paper describes the results of an investigation into the performance of Coriolis, Electromagnetic, and clamp-on single-beam Ultrasonic flowmeters operating with non-Newtonian liquids. The flowmeters have been tested on Newtonian liquids (water and a glycerine/water solution) and non-Newtonian liquids (various polymer solutions and a synthetic clay) with flow rates that span the laminar and turbulent regions. It has been shown that the Coriolis flowmeter operates within the manufacturer’s specification with non-Newtonian liquids. The Electromagnetic flowmeter showed a slight deviation duri
APA, Harvard, Vancouver, ISO, and other styles
6

Da Roz, Fa´bio, Marcus Vini´cius B. Nunes, Ju´lio Ce´sar de M. Palhares, and Nancy Flora Alves Pinto. "Performance Analysis of Turbine Meter and Ultrasonic Meter." In 2008 7th International Pipeline Conference. ASMEDC, 2008. http://dx.doi.org/10.1115/ipc2008-64085.

Full text
Abstract:
The performance analysis of Turbine - Type and Ultrasonic natural gas flowmeters installed in series in the same stream. The instruments were connected to flow computers for a period of 18 months. During this time all measured differences between the Ultrasonic flowmeter and the Turbine flowmeter were recorded. The performance between instruments is presented in graphs. Throughout this time all system maintenance events were recorded.
APA, Harvard, Vancouver, ISO, and other styles
7

Rotondo, J. "Injection Allocation in Secondary Petroleum Recovery." In SPE Argentina Region Young Professionals Symposium. SPE, 2024. http://dx.doi.org/10.2118/223496-ms.

Full text
Abstract:
Abstract This study proposes an enhancement to the injection allocation method in Golfo San Jorge aimed at increasing the accuracy of injected flow rate measurements during secondary oil recovery, with the objective of reducing the number of flowmeter interventions in the field. Two new correction factors are introduced in the calculation of injection allocation, which consider the stabilization of the injector well after an intervention with wireline or workover equipment, as well as the measurement obtained from the flowmeter associated with the well or an external flowmeter. The analysis in
APA, Harvard, Vancouver, ISO, and other styles
8

Comes, M., P. Drumea, M. Blejan, I. Dutu, and A. Vasile. "Ultrasonic Flowmeter." In 2006 29th International Spring Seminar on Electronics Technology. IEEE, 2006. http://dx.doi.org/10.1109/isse.2006.365135.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Hissam, D. Andy, Mike Leberman, and Rick McLeroy. "Testing and Comparative Evaluation of Space Shuttle Main Engine Flowmeter Bearings." In World Tribology Congress III. ASMEDC, 2005. http://dx.doi.org/10.1115/wtc2005-63299.

Full text
Abstract:
This paper provides a summary of testing of Space Shuttle Main Engine (SSME) flowmeter bearings and cage material. This testing was conducted over a several month period in 2004 at the Marshall Space Flight Center (MSFC). The test program’s primary objective was to compare the performance of bearings using the existing cage material and bearings using a proposed replacement cage material. In order to meet the test objectives for this program, a flowmeter test rig was designed and fabricated to measure both breakaway and running torque for a flowmeter assembly. Other test parameters, such as mo
APA, Harvard, Vancouver, ISO, and other styles
10

Ferreira, Ana Lui´sa A. S., Andre´ Paulo Kotchetkoff Neto, and Ma´rcio Manha˜es Gomes de Almeida. "Effects of Ultrasonic Flowmeter Internal Diameter Differences on the OSBRA Pipeline Measurement Results." In 2010 8th International Pipeline Conference. ASMEDC, 2010. http://dx.doi.org/10.1115/ipc2010-31110.

Full text
Abstract:
The objective of this paper is to describe the effect of the differences between the pipe and the ultrasonic flowmeter internal diameters on the flow-rate measurement results, and to compare the values found with the differences on the pipe balance. The work included field analysis, numerical simulation and meter calibration. The ultrasonic meter balance differences were the reason for this research. The field analysis presents the balance and internal diameter differences. The numerical simulations comprise one, two and three-path meters with arrangements similar to the OSBRA meters. Three fl
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Flowmeter"

1

Mills, Chris. PR-363-18604-Z01 Mass-Based Proving Methods for Mass Flow Meters. Pipeline Research Council International, Inc. (PRCI), 2019. http://dx.doi.org/10.55274/r0011579.

Full text
Abstract:
Due to the increased utilization of mass-based flowmeters for flow measurement of hydrocarbons, there is a requirement for a direct method for proving/calibrating a mass flowmeter directly using a measured mass. The project objective was to identify, review and rank suitable methods for proving/calibrating a mass-based flowmeter directly using a measured mass. The preferred method has been recommended and potential changes to industry standards have been highlighted. This report has a related webinar.
APA, Harvard, Vancouver, ISO, and other styles
2

Flach, G. P. Electromagnetic Borehole Flowmeter Testing in R-Area. Office of Scientific and Technical Information (OSTI), 2000. http://dx.doi.org/10.2172/765407.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Scott, Jennifer L. Flow conditioner tests for three orifice flowmeter sizes. National Bureau of Standards, 1994. http://dx.doi.org/10.6028/nist.tn.1367.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Yeh, T. T. Flowmeter installation effects due to a generic header. National Bureau of Standards, 1996. http://dx.doi.org/10.6028/nist.tn.1419.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Aronson, David, and Alexander Heifetz. Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter. Office of Scientific and Technical Information (OSTI), 2021. http://dx.doi.org/10.2172/1826477.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Flach, Gregory P., and L. Romanowsk. Electromagnetic Borehole Flowmeter (EBF) Testing in R-area (U). Office of Scientific and Technical Information (OSTI), 2000. http://dx.doi.org/10.2172/1469275.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Johnson, Aaron N., and John D. Wright. Gas flowmeter calibrations with the 26m^3 PVTt standard. National Institute of Standards and Technology, 2004. http://dx.doi.org/10.6028/nist.sp.1046.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Wright, John D., Jean-Philippe Kayl, Aaron N. Johnson, and Gina M. Kline. Gas flowmeter calibrations with the working gas flow standard. National Institute of Standards and Technology, 2009. http://dx.doi.org/10.6028/nist.sp.250-80.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Flach, G. P. Electromagnetic Borehole Flowmeter Testing at the H-Area Extraction Wells. Office of Scientific and Technical Information (OSTI), 2002. http://dx.doi.org/10.2172/799461.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Mattingly, G. E., and T. T. Yeh. NBS' industry - government consortium research program on flowmeter installation effects :. National Bureau of Standards, 1988. http://dx.doi.org/10.6028/nist.ir.88-3898.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!