Academic literature on the topic 'Modeling of relay protection'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Modeling of relay protection.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Modeling of relay protection"

1

Khoa, N. M., and D. D. Tung. "Modeling for Development of Simulation Tool: Impact of TCSC on Apparent Impedance Seen by Distance Relay." Engineering, Technology & Applied Science Research 8, no. 5 (2018): 3332–37. http://dx.doi.org/10.48084/etasr.2199.

Full text
Abstract:
The impact of thyristor controlled series capacitor (TCSC) on distance protection relays in transmission lines is analyzed in this paper. Voltage and current data are measured and collected at the relay locations to calculate the apparent impedance seen by distance protection relays in the different operating modes of the TCSC connected to the line. Short-circuit faults which occur at different locations on the power transmission line are considered in order to locate the fault for the purpose of evaluating the impact of TCSC on the distance protection relay. Matlab/Simulink simulation softwar
APA, Harvard, Vancouver, ISO, and other styles
2

Khoa, Ngo Minh, and Doan Duc Tung. "Modeling for Development of Simulation Tool: Impact of TCSC on Apparent Impedance Seen by Distance Relay." Engineering, Technology & Applied Science Research 8, no. 5 (2018): 3332–37. https://doi.org/10.5281/zenodo.1490318.

Full text
Abstract:
The impact of thyristor controlled series capacitor (TCSC) on distance protection relays in transmission lines is analyzed in this paper. Voltage and current data are measured and collected at the relay locations to calculate the apparent impedance seen by distance protection relays in the different operating modes of the TCSC connected to the line. Short-circuit faults which occur at different locations on the power transmission line are considered in order to locate the fault for the purpose of evaluating the impact of TCSC on the distance protection relay. Matlab/Simulink simulation softwar
APA, Harvard, Vancouver, ISO, and other styles
3

Nwachi, G.U., P.I. Obi, E.A. Amako, and C.S. Ezeonye. "Modeling and Simulation of a Coordinated Power System Protection using Overcurrent Relay." Nigerian Research Journal of Engineering and Environmental Sciences 7, no. 1 (2022): 238–49. https://doi.org/10.5281/zenodo.6725273.

Full text
Abstract:
<em>The efficient and reliable operation of a protection system cannot be overemphasized as any shortfall in such system has both huge financial implications and makes the station dangerous and unsafe. The data for the overcurrent relay coordination analysis used in this study was obtained from the Ohiya Umuahia 132/33 kV substation of the Transmission Company of Nigeria (TCN) while the electric transient analyzer program (ETAP) software was used for the analysis. Firstly, a three-phase (3-phase) short circuit test was conducted on the network at the 33 kV busbar. Then, a detailed sequence of
APA, Harvard, Vancouver, ISO, and other styles
4

Mishra, Debani Prasad, Rudranarayan Senapati, Suman Patra, and Bimalendu Mishra. "Enhancing the Performance of Reverse Power Relay for Generator Protection." WSEAS TRANSACTIONS ON POWER SYSTEMS 16 (December 28, 2021): 336–43. http://dx.doi.org/10.37394/232016.2021.16.33.

Full text
Abstract:
The generator is the most important component in energy generation, and it needs to be protected from both internal and external disturbance. Reverse power relays (RPR), with the directional relay being the most commonly utilized as the principal safeguard, are used to trip the turbine generators to minimize the damage of prime mover. Modeling tools are helpful for learning the basics of a power system, especially for newbie engineers. These tools assist novice engineers in modulating the system in both normal and abnormal situations. This paper demonstrates how to model and simulate a digital
APA, Harvard, Vancouver, ISO, and other styles
5

Al-Badrany, Ahmad A. "Modeling and Simulation of Out of Step Blocking Relay for Power Swing using Concentric Polygons Scheme." Tikrit Journal of Engineering Sciences 17, no. 1 (2010): 21–31. http://dx.doi.org/10.25130/tjes.17.1.08.

Full text
Abstract:
This paper investigates a power swing effect on a distance protection relay performance installed on (HV/EHV) transmission line as well as power system stability. A conventional distance relay can’t properly operate under transient stability conditions; therefore, it cause mol-operation, and it will adversely impact on its trip signals. To overcome this problem, the Out Of Step (OOS) relay has modeled and simulated to joint with distance relay to supervise and control on its trip signals response. The setting characteristics technique of the OOS based on concentric polygons scheme method to de
APA, Harvard, Vancouver, ISO, and other styles
6

Marei, Marwa M., Manal H. Nawir, and Ali Abdul Razzaq Altahir. "An improved technique for power transformer protection using fuzzy logic protective relaying." Indonesian Journal of Electrical Engineering and Computer Science 22, no. 3 (2021): 1754–60. https://doi.org/10.11591/ijeecs.v22.i3.pp1754-1760.

Full text
Abstract:
The three-phase power transformer in the transmission or distribution substations represents one of the essential devices on electric power networks. Losing this devise cause a disconnection of the power utility to a large number of electrical loads. The robust protection system must be designed to protect the device during abnormal operations. A complete protection system for a poly-phase power transformer for one of the Karbala transmission networks (East Karbala substation) is modeled and simulated, adopting a fuzzy logic protective relaying using MATLAB/SIMULINK environment. This study dis
APA, Harvard, Vancouver, ISO, and other styles
7

Yang, Ting, Xiyang Qian, and Liqing Ren. "Application of Artificial Intelligence Algorithm in Relay Protection of Distribution Network." International Transactions on Electrical Energy Systems 2022 (August 29, 2022): 1–12. http://dx.doi.org/10.1155/2022/7138367.

Full text
Abstract:
A distribution network in supply chain management increases product reachability and handling density across different warehouses and customers. Relays in the distribution network prevent congestion, supply stagnancy, and delayed deliveries. Protecting the relay functions and streamlining them are tedious due to the varying vehicle and goods densities. This article introduces a populous relay management scheme (PRMS) for multi-access in delivery networks to address the problem above. The proposed scheme relies on vehicle and goods movement frequency for improving the relay utilization without
APA, Harvard, Vancouver, ISO, and other styles
8

Zakri, Azriyenni Azhari, and Fahrul Rozi. "MODELING TO IMPROVE THE PERFORMANCE OF REVERSE POWER RELAY IN GENERATOR." SINERGI 24, no. 3 (2020): 231. http://dx.doi.org/10.22441/sinergi.2020.3.008.

Full text
Abstract:
The generator is the primary component in electricity generation and requires a protection system from internal and external interference that occurs. This study considers how to improve the performance of relays in power plants. A model of a generator that is executed in a fault condition to reset the protective equipment, namely Reverse Power Relay (RPR). The study is intended to model the state of internal and external fault on the generator by applying a working principle of RPR. The model is designed to anticipate the actual fault in the generator. The simulation results obtained output s
APA, Harvard, Vancouver, ISO, and other styles
9

Cherkashyna, Veronika, and Vladyslav Tsyupa. "ANALYSIS OF DIFFERENTIAL RELAY PROTECTION ALGORITHMS AND THEIR MODELLING IN MATLAB." Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency, no. 1 (6) (July 9, 2023): 113–18. http://dx.doi.org/10.20998/2224-0349.2023.01.13.

Full text
Abstract:
The paper is devoted to identifying the prospects for software implementation of differential relay protection. The purpose of this study was to analyse the algorithms of the devices' operation, which allowed to create a mathematical model in the MATLAB software environment with the prospect of integration in the form of a single regional relay protection server into the unified energy system of Ukraine. It has been established that virtual models have both advantages and disadvantages compared to digital-analog devices. Their positive feature is that, due to the block principle of constructio
APA, Harvard, Vancouver, ISO, and other styles
10

Doletskaya, Larisa I., Vladislav I. Ziryukin, and Roman V. Solopov. "An electric power system object model creating experience for researching the operation of digital means of relay protection and automation." Journal Of Applied Informatics 16, no. 4 (2021): 83–95. http://dx.doi.org/10.37791/2687-0649-2021-16-4-83-95.

Full text
Abstract:
The article is devoted to the operation logic modeling of relay protection and automation terminals in order to their verification, adjustment and further exploitation. The problem of adjusting protection terminals mutual interaction is unlikely to appear in real conditions due to wide variety of them. The authors propose a solution to this problem by creating a verified model based on a digital twin of an electric power network section created in the MatLab software package. This model helps to study the functioning of the researched protection settings in nominal, repair, emergency and post-
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Modeling of relay protection"

1

Ristanovic, Dragan. "New methodology for transmission line relay testing and evaluation using advanced tools." Texas A&M University, 2003. http://hdl.handle.net/1969.1/355.

Full text
Abstract:
Protective relays are important parts of the power system. The protection guards valuable equipment, and protective relays play a vital role in performing the task. The relay detects fault conditions within an assigned area, opens and closes output contacts to cause the operation of other devices under its control. The relay acts to operate the appropriate circuit breakers to prevent damage to personnel and property. To ensure consistent reliability and proper operation, protective relay equipment must be evaluated and tested. The importance of the relay evaluation issue is linked to capabili
APA, Harvard, Vancouver, ISO, and other styles
2

Cho, Sungmin. "Modeling and testing of digital protection relay for an induction motor." Thesis, Cho, Sungmin (2010) Modeling and testing of digital protection relay for an induction motor. Other thesis, Murdoch University, 2010. https://researchrepository.murdoch.edu.au/id/eprint/4117/.

Full text
Abstract:
The project details the modelling of the induction motor SEL701 Relay in PowerFactory. In order to prove operational reliability, both off-line and on-line testing were implemented to verify the characteristic curve of the relay by measuring trip times. Prior to modelling the relay, the thermal limit curves of the motor were studied to scheme the motor protection relay. In addition, the requirement of motor protection is discussed and the elements of a protection relay corresponding to the requirements are presented. The results indicate that the off-line (simulation) and on-line test have con
APA, Harvard, Vancouver, ISO, and other styles
3

Patel, Daxe. "Modeling and testing of an instantaneous overcurrent relay using VTB and VTB-RT." Master's thesis, Mississippi State : Mississippi State University, 2006. http://sun.library.msstate.edu/ETD-db/ETD-browse/browse.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Aminu, Maruf Asumo. "Modeling and Simulation of Protective Relay for Short Circuits in AC Micro-grids using Fuzzy Logic." Thesis, Curtin University, 2016. http://hdl.handle.net/20.500.11937/51625.

Full text
Abstract:
The duo of high human appetite for electricity in the 21st century and high human population growth rate entail inadequacy of contemporary electric power protective systems for the emerging micro-grid. This thesis presents results of a research which seeks to propose a new model of protective device for short circuits in ac micro-grids. Response of the proposed relay is consistent with a reliable device. Consequently, a protective relay for short circuits in micro-grids is proposed.
APA, Harvard, Vancouver, ISO, and other styles
5

Nozdrenko, Valerii Stanislavovych, Валерий Станиславович Ноздренков, Валерій Станіславович Ноздренков та Е. А. Шолудько. "Моделирование релейной защиты с помощью среды SPAC 800". Thesis, Изд-во СумДУ, 2008. http://essuir.sumdu.edu.ua/handle/123456789/4125.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Magrin, Fabiano Gustavo Silveira 1978. "Modelagem de um relé de proteção diferencial de transformador no RTDS." [s.n.], 2014. http://repositorio.unicamp.br/jspui/handle/REPOSIP/259599.

Full text
Abstract:
Orientador: Maria Cristina Dias Tavares<br>Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação<br>Made available in DSpace on 2018-08-25T04:21:56Z (GMT). No. of bitstreams: 1 Magrin_FabianoGustavoSilveira_M.pdf: 5471875 bytes, checksum: 204630879d78c9f5167f324d6d0f5fe9 (MD5) Previous issue date: 2014<br>Resumo: Devido à dificuldade de execução de testes em sistemas reais os engenheiros procuram ferramentas e modelos para simular ou emular os sistemas reais em laboratório. Nesse sentido, o objetivo deste projeto de pesquisa foi desenvol
APA, Harvard, Vancouver, ISO, and other styles
7

Cassata, Joseph Frank. "Relay Protection Scheme for Special Power Flow Controllers." Youngstown State University / OhioLINK, 2020. http://rave.ohiolink.edu/etdc/view?acc_num=ysu1595355623363128.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Abyaneh, Hossein Askarian. "Assessment of IDMT and distance relay settings." Thesis, University of Manchester, 1988. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.332331.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Siyambalapitiyage, Berty. "Protection of ungrounded systems using an advanced relay element." Thesis, Siyambalapitiyage, Berty (2010) Protection of ungrounded systems using an advanced relay element. Other thesis, Murdoch University, 2010. https://researchrepository.murdoch.edu.au/id/eprint/4066/.

Full text
Abstract:
The aim of this thesis project is to investigate single line to ground faults in an ungrounded system and determine an effective fault detection method. Ungrounded system analysis is conducted using ICAP simulation. The fault detection method is focused on three different parts. The first part is used to identify the faulted feeder. Second part is for identifying the faulted phase and the last part is for estimating the fault distance. After simulating the model of an ungrounded system using ICAP, it can be observed that when a ground fault is present, the voltage magnitude of the unfau
APA, Harvard, Vancouver, ISO, and other styles
10

Lima, Jose Augusto. "Relay Attack in RFiD Systems Analysis and Modeling." Thesis, University of Ottawa (Canada), 2011. http://hdl.handle.net/10393/28935.

Full text
Abstract:
A relay attack on an RFiD system is carried out by a team of two attackers: one stationed near the victim, and using a rogue Reader to activate the victim's TAG; and another stationed near the legitimate Reader, using a high-speed communication system to relay the communication between the victim's TAG to the legitimate Reader through the attackers in real time. The relay attack is one of the most significant threats to the security of RFiD systems, because it is difficult to detect, is not thwarted by standard challenge-and-response security protocols and is independent of any cryptographic a
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Modeling of relay protection"

1

Biryulin, Vladimir, Aleksey None, Dar'ya Kudelina, Oleg Larin, and Anton Tancyura. Relay protection and automation systems elektroenergeticheskim. INFRA-M Academic Publishing LLC., 2020. http://dx.doi.org/10.12737/1058880.

Full text
Abstract:
The manual includes basic information about the element base of relay protection and automation, principles of operation and circuit implementation of various types of relay protection and automation systems, algorithms of calculation of parameters of the action of relay protection and automation.&#x0D; Designed for students in specialty "power and electrical engineering", as well as professionals involved in the design and operation of relay protection and automation of electric power systems.
APA, Harvard, Vancouver, ISO, and other styles
2

Goremykin, Sergey. Relay protection and automation of electric power systems. INFRA-M Academic Publishing LLC., 2021. http://dx.doi.org/10.12737/1048841.

Full text
Abstract:
The textbook describes the main issues of the theory of relay protection and automation of electric power systems. The structure and functional purpose of protection devices and automation of power transmission lines of various configurations, synchronous generators, power transformers, electric motors and individual electrical installations are considered. For each of the types of protection of the above objects, the structure, the principle of operation, the order of selection of settings are given, the advantages and disadvantages are evaluated, indicating the scope of application. The manu
APA, Harvard, Vancouver, ISO, and other styles
3

Karavas, H. Protection relay test bench based on IBM P.C. UMIST, 1994.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Dorohin, Evgeniy. Fundamentals of operation of relay protection and automation. INFRA-M Academic Publishing LLC., 2024. http://dx.doi.org/10.12737/2125174.

Full text
Abstract:
The textbook contains a brief description of the most common relay protection devices, automation, secondary switching elements and the procedure for their operational maintenance.&#x0D; It is intended for the operational personnel of power plants, substations, field teams of electric networks engaged in the operation of electrical equipment, for dispatchers of the joint dispatching service of electric networks and regional dispatching departments, employees of relay protection and automation services of various levels and technical managers of relevant organizations.
APA, Harvard, Vancouver, ISO, and other styles
5

Kezunovic, Mladen, Jinfeng Ren, and Saeed Lotfifard. Design, Modeling and Evaluation of Protective Relays for Power Systems. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-20919-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

SAE International Congress & Exposition (1992 Detroit, Mich.). Analytical modeling and occupant protection technologies. Society of Automotive Engineers, 1992.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Yakimov, A. S. Thermal Protection Modeling of Hypersonic Flying Apparatus. Springer International Publishing, 2018. http://dx.doi.org/10.1007/978-3-319-78217-1.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

P, Zannetti, ed. Environmental modeling. Computational Mechanics Publications, 1993.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
9

Bonnet, Pierre. Enterprise data governance: Reference and master data management, semantic modeling. ISTE Ltd., 2010.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
10

Pierre, Bonnet. Enterprise data governance: Reference and master data management, semantic modeling. ISTE Ltd., 2010.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Book chapters on the topic "Modeling of relay protection"

1

Kezunovic, Mladen, Jinfeng Ren, and Saeed Lotfifard. "Modeling of Digital Relay and Power System Signals." In Design, Modeling and Evaluation of Protective Relays for Power Systems. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-20919-7_4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Kezunovic, Mladen, Jinfeng Ren, and Saeed Lotfifard. "Design and Implementation of Relay Communication Schemes and Trip Logic." In Design, Modeling and Evaluation of Protective Relays for Power Systems. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-20919-7_5.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Kezunovic, Mladen, Jinfeng Ren, and Saeed Lotfifard. "Design and Implementation of Overcurrent, Pilot, and Distance Protection." In Design, Modeling and Evaluation of Protective Relays for Power Systems. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-20919-7_6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Kezunovic, Mladen, Jinfeng Ren, and Saeed Lotfifard. "Design and Implementation of Transformer and Busbar Differential Protection." In Design, Modeling and Evaluation of Protective Relays for Power Systems. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-20919-7_7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Abood, Samir I., and John Fuller. "Overcurrent Relay." In Power System Protection and Relaying. CRC Press, 2023. http://dx.doi.org/10.1201/9781003394389-6.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Kezunovic, Mladen, Jinfeng Ren, and Saeed Lotfifard. "Testing of Digital Protective Relays." In Design, Modeling and Evaluation of Protective Relays for Power Systems. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-20919-7_8.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Zheng, Xinyu, Jiliang Zhang, and Gaofeng Pan. "UAV Relay Communications." In UAV Communications: Modeling and Analyses. Springer Nature Singapore, 2024. http://dx.doi.org/10.1007/978-981-97-0383-8_5.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Li, Xiuzhi, and Guihua Qiu. "Relay Protection Stability of Intelligent Substation." In Lecture Notes in Mechanical Engineering. Springer Nature Singapore, 2023. http://dx.doi.org/10.1007/978-981-99-2921-4_66.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Kezunovic, Mladen, Jinfeng Ren, and Saeed Lotfifard. "Basics of Protective Relaying and Design Principles." In Design, Modeling and Evaluation of Protective Relays for Power Systems. Springer International Publishing, 2016. http://dx.doi.org/10.1007/978-3-319-20919-7_3.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Kam, Hei, and Fred Chen. "Design and Modeling of Micro-relay." In Microsystems and Nanosystems. Springer New York, 2014. http://dx.doi.org/10.1007/978-1-4939-2128-7_2.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Modeling of relay protection"

1

Zakharov, V. O., D. I. Baranova, and R. V. Solopov. "Modeling of Automated Electric Power System in Simintech Software Package." In 2024 7th International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA). IEEE, 2024. https://doi.org/10.1109/rpa65165.2024.10932939.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Vaytelenok, L. V., V. S. Kovzhenkin, and R. V. Solopov. "Modeling and Analysis of the Functioning of Digital Relay Protection with Remote Current Measuring Transducers." In 2024 7th International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA). IEEE, 2024. https://doi.org/10.1109/rpa65165.2024.10932930.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Blagorazumov, D. O., A. A. Volkova, and M. S. Malyutin. "Analysis of Formulas for Calculating the Magnetizing Inrush Current and Their Application for Modeling Purposes." In 2024 7th International Youth Scientific and Technical Conference on Relay Protection and Automation (RPA). IEEE, 2024. https://doi.org/10.1109/rpa65165.2024.10932965.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Cheng, Zheyuan, Trupal R. Patel, Juergen Holbach, et al. "Assessing Inverter-Based Resources Modeling Gaps in Commonly Used Short-Circuit Programs." In 2025 78th Annual Conference for Protective Relay Engineers (CFPR). IEEE, 2025. https://doi.org/10.1109/cfpr67343.2025.11013194.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Baeté, C., L. Bortels, B. Van Den Bossche, M. Purcar, and J.-M. Dewilde. "CP System Validation of Offshore Structures through Modeling." In CORROSION 2012. NACE International, 2012. https://doi.org/10.5006/c2012-01657.

Full text
Abstract:
Abstract Nowadays offshore structures are typically equipped with a sacrificial anode cathodic protection system (SACP). Design and application of SACP systems is well documented and most owners of marine equipment rely on this traditional approach. SACP systems for big structures result in a large amount of anodes increasing the mechanical load on the structure, installation cost (welding) and the release of soluble metals into the environment. Moreover, monitoring of the CP performance requires access to the anodes in order to verify the material consumption resulting in expensive ROV inspec
APA, Harvard, Vancouver, ISO, and other styles
6

Parker, Keith, Trey Johnston, Christophe Baeté, and Michael Snow. "Case Study: Integrated External Corrosion Management for a 12-Inch Crude Oil Pipeline." In CONFERENCE 2023. AMPP, 2023. https://doi.org/10.5006/c2023-18970.

Full text
Abstract:
Abstract Recent years have seen advances in controlling external corrosion for buried pipelines. Specialized equipment and methods for assessing cathodic protection effectiveness and AC corrosion threats, state-of-the art corrosion sensing equipment, remote monitoring dataloggers, and advanced modeling techniques offer operators technologically advanced means and methods for managing external corrosion risks. While proof of compliance continues to rely on long-established field tests and monitoring cycles, there are opportunities to improve external corrosion management programs to incorporate
APA, Harvard, Vancouver, ISO, and other styles
7

Ruiz, Jose, and Montie Smith. "Virtual Protection Relay: Myth or Reality?" In 2024 77th Annual Conference for Protective Relay Engineers (CFPR). IEEE, 2024. http://dx.doi.org/10.1109/cfpr61009.2024.10743011.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Thomas, Mini S., Anupama Prakash, and Nizamuddin. "Modeling and Testing of Protection Relay IED." In 2008 Joint International Conference on Power System Technology and IEEE Power India Conference (POWERCON). IEEE, 2008. http://dx.doi.org/10.1109/icpst.2008.4745389.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Khani, Hadi, Mohamed Maria, and Saman Alaeddini. "Automated Modeling of Power System Protective Devices for Advanced Analysis of Protection System Performance." In 2019 72nd Conference for Protective Relay Engineers (CPRE). IEEE, 2019. http://dx.doi.org/10.1109/cpre.2019.8765889.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

V. Lopes, Felipe, Jônatas S. Costa, Tiago R. Honorato, et al. "Transmission Line Protection Performance in the Presence of Wind Power Plants: Study on the Busbar Capacitance Modeling During Relay Testing Procedures." In Simpósio Brasileiro de Sistemas Elétricos - SBSE2020. sbabra, 2020. http://dx.doi.org/10.48011/sbse.v1i1.2184.

Full text
Abstract:
In this paper, the performance of transmission line differential and distance protection functions available in phasor- and time-domain-based relays is evaluated considering the presence of wind power plants. In the proposed study, an investigation on the system busbar capacitance modeling during relay testing procedures is carried out, indicating differences verified in the number of operations and operation times of four real protective relays. The obtained results reveal that the busbar capacitance modeling is critical for some protection functions, affecting mainly the reliability of trans
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Modeling of relay protection"

1

McDermott, Thomas E., Jeffrey D. Doty, James G. O'Brien, Crystal R. Eppinger, and Tamara Becejac. Cybersecurity for Distance Relay Protection. Office of Scientific and Technical Information (OSTI), 2020. http://dx.doi.org/10.2172/1602545.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Burkes, Klaehn, and Ian Webb. Effect of GPS Manipulation to Traditional and Next Generation Relay Protection. Office of Scientific and Technical Information (OSTI), 2020. http://dx.doi.org/10.2172/1651101.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Meliopoulos, Sakis, George Cokkinedes, and Kaiyu Liu. Estimation Based Protection Relay-Application to Distribution System with High DER Penetration. Office of Scientific and Technical Information (OSTI), 2021. http://dx.doi.org/10.2172/1996378.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

BURKES, KLAEHN, and IAN WEBB. EFFECT OF GPS MANIPULATION TO TRADITIONAL AND NEXT GENERATION RELAY PROTECTION FINAL REPORT. Office of Scientific and Technical Information (OSTI), 2021. http://dx.doi.org/10.2172/1827959.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Hossain-McKenzie, Shamina, Nicholas Jacobs, Adam Summers, et al. Harmonized Automatic Relay Mitigation of Nefarious Intentional Events (HARMONIE) - Special Protection Scheme (SPS). Office of Scientific and Technical Information (OSTI), 2022. http://dx.doi.org/10.2172/1890265.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Bailey, David M. Modeling and Simulation for Force Protection Unclassified. Defense Technical Information Center, 2002. http://dx.doi.org/10.21236/ada408571.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

VON BOETTICHER, Albrecht, Johannes HÜBL, Corinna WENDELER, and Axel VOLKWEIN. Modeling the Impact of Shallow Landslides on Flexible Protection Barriers. Cogeo@oeaw-giscience, 2011. http://dx.doi.org/10.5242/iamg.2011.0285.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Cipiti, Benjamin, Timothy Dunn, Samual Durbin, et al. Material Protection, Accounting, and Control Technologies (MPACT): Modeling and Simulation Roadmap. Office of Scientific and Technical Information (OSTI), 2016. http://dx.doi.org/10.2172/1296697.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Tow Leong, Tiang, Mohd Saufi Ahmad, Ang Qian Yee, et al. HANDBOOK OF ELECTRICAL SYSTEM DESIGN FOR NON-DOMESTIC BUILDING. Penerbit Universiti Malaysia Perlis, 2023. http://dx.doi.org/10.58915/techrpt2023.001.

Full text
Abstract:
This technical report presents the electrical system installation design for development of a factory with 1 storey and 2 storey of offices. Firstly, the general methodology of designing the electrical system are elaborated in this report. As overall, the methodologies in designing the components of the electrical system are explained and elaborated, which included: (a) load and maximum demand estimation; (b) miniature circuit breaker (MCB) selection; (c) moulded case circuit breaker (MCCB) selection; (d) air circuit breaker (ACB) selection, (e) residual current device (RCD) selection; (f) pro
APA, Harvard, Vancouver, ISO, and other styles
10

Roth, Stephen. The Integration of Building Information Modeling with Fire Protection Systems, Software, and Workflows. SFPE Foundation, 2024. https://doi.org/10.64167/f99p-f0cf.

Full text
Abstract:
The objectives of this SFPE Foundation research project were to (1) investigate existing software tools and schemas, and the integration of these schemas into building information modeling (BIM) to fire engineering workflows; (2) Interview various stakeholders, including fire engineers, members of the SFPE Foundation, building owners, and BIM and analysis software vendors; (3) After careful analysis, select the best tools and workflows and incorporate them into a final user report. This research project focuses on three overriding themes in relation to fire protection engineering: software too
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!