Academic literature on the topic 'Particle beam detectors'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Particle beam detectors.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Particle beam detectors"

1

Jiménez, José Miguel, and Paolo Chiggiato. "Vacuum science and technology at CERN." Europhysics News 51, no. 4 (2020): 24–26. http://dx.doi.org/10.1051/epn/2020404.

Full text
Abstract:
Vacuum is essential in particle accelerators. Low gas density allows charged particles beams to circulate without excessive losses. Indeed, beam losses are detrimental for instrumentation; they increase induced radioactivity, background noise in particle detectors, and beam-induced heat loads to cryogenic equipment.
APA, Harvard, Vancouver, ISO, and other styles
2

Waid, Simon, Andreas Gsponer, Jürgen Burin, Philipp Gaggl, Richard Thalmeier, and Thomas Bergauer. "SiC based beam monitoring system for particle rates from kHz to GHz." Journal of Instrumentation 19, no. 04 (2024): C04055. http://dx.doi.org/10.1088/1748-0221/19/04/c04055.

Full text
Abstract:
Abstract The extremely low dark current of silicon carbide (SiC) detectors, even after high-fluence irradiation, was utilized to develop a beam monitoring system for a wide range of particle rates, i.e., from the kHz to the GHz regime. The system is completely built from off-the-shelf components and is focused on compactness and simple deployment. Beam tests using a 50 um thick SiC detector reveal, that for low fluences, single particles can be detected and counted. For higher fluences, beam properties were extracted from beam cross sections using a silicon strip detector. Overall, accurate re
APA, Harvard, Vancouver, ISO, and other styles
3

Oancea, C., A. Resch, S. Barna, et al. "High-count-rate particle tracking in proton and carbon radiotherapy with Timepix2 operated in ultra-short acquisition time." Journal of Instrumentation 19, no. 11 (2024): C11002. http://dx.doi.org/10.1088/1748-0221/19/11/c11002.

Full text
Abstract:
Abstract This work investigates the operational acquisition time limits of Timepix3 and Timepix2 detectors operated in frame mode for high-count rate of high deposited energy transfer particles. Measurements were performed using alpha particles from a 241Am laboratory source and proton and carbon ion beams from a synchrotron accelerator. The particle count rate upper limit is determined by overlapping per-pixel particle signals, identifiable by the hits per pixel counter > 2, indicating the need to decrease acquisition time. On the other hand, the lower limit is the time required to collect
APA, Harvard, Vancouver, ISO, and other styles
4

Simeonov, R., and V. Kozhuharov. "Influence of beam content composition on testbeam studies of hadron calorimeters." Journal of Physics: Conference Series 2794, no. 1 (2024): 012002. http://dx.doi.org/10.1088/1742-6596/2794/1/012002.

Full text
Abstract:
Abstract Hadron calorimeters are one of the most important detectors in the contemporary nuclear and particle physics experiments. Their construction and verification process takes years in designing, testing and data analysis of prototypes. Crucial step for the prototypes are tests performed by exposing the detectors to charge particle beams. Here we study the impact of the different beam content composition to one of the main properties of the hadron calorimeters – their energy resolution. We implement a test detector - Metal Hadronic Calorimeter (MACA) in GEANT4 environment and we perform d
APA, Harvard, Vancouver, ISO, and other styles
5

Kim, Sungjoon, Manoj B. Jadhav, Vikas Berry, Jessica E. Metcalfe, and Anirudha V. Sumant. "Novel indium phosphide charged particle detector characterization with a 120 GeV proton beam." Journal of Instrumentation 19, no. 08 (2024): P08016. http://dx.doi.org/10.1088/1748-0221/19/08/p08016.

Full text
Abstract:
Abstract Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and radiation hardness. To explore the possibility, promising candidate materials were selected, and particle tracking detectors were fabricated. An indium phosphide detector with a metal-intrinsic-metal structure has been fabricated for particle tracking. The detector was tested using radioactive sources and a high energy proton beam at Fermi National Accele
APA, Harvard, Vancouver, ISO, and other styles
6

Gunsing, F., F. Belloni, E. Berthoumieux, M. Diakaki, E. Dupont, and E. Ferrer-Ribas. "MicroMegas-based detectors for time-of-flight measurements of neutron-induced reactions." EPJ Web of Conferences 239 (2020): 17007. http://dx.doi.org/10.1051/epjconf/202023917007.

Full text
Abstract:
MicroMegas detectors are versatile gaseous detectors which are used for ionizing particle detection. A MicroMegas detector consists of two adjacent gas-filled volumes. One volume acts as a drift region with an electric field operating in the ionization chamber regime, the second volume is the amplification region acting as a parallel-plate avalanche counter. The use of the microbulk technique allows the production of thin, radiation resistant, and low-mass detector with a highly variable gain. Such MicroMegas detectors have been developed and used in combination with neutron time-of-flight mea
APA, Harvard, Vancouver, ISO, and other styles
7

Oancea, C., C. Bălan, J. Pivec, et al. "Stray radiation produced in FLASH electron beams characterized by the MiniPIX Timepix3 Flex detector." Journal of Instrumentation 17, no. 01 (2022): C01003. http://dx.doi.org/10.1088/1748-0221/17/01/c01003.

Full text
Abstract:
Abstract This work aims to characterize ultra-high dose rate pulses (UHDpulse) electron beams using the hybrid semiconductor pixel detector. The Timepix3 (TPX3) ASIC chip was used to measure the composition, spatial, time, and spectral characteristics of the secondary radiation fields from pulsed 15–23 MeV electron beams. The challenge is to develop a single compact detector that could extract spectrometric and dosimetric information on such high flux short-pulsed fields. For secondary beam measurements, PMMA plates of 1 and 8 cm thickness were placed in front of the electron beam, with a puls
APA, Harvard, Vancouver, ISO, and other styles
8

Dierlamm, Alexander, Matthias Balzer, Felix Ehrler, et al. "A Beam Monitor for Ion Beam Therapy Based on HV-CMOS Pixel Detectors." Instruments 7, no. 1 (2023): 9. http://dx.doi.org/10.3390/instruments7010009.

Full text
Abstract:
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world-wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation is the distinct peak in the depth-dependent energy deposition, which can be exploited to accurately deposit doses in the tumor cells. To guarantee this, high accuracy in monitoring and control of the particle beam is of the utmost importance. Before the particle beam enters the patient, it traverses a monitoring system which has to give fast feedback to the b
APA, Harvard, Vancouver, ISO, and other styles
9

Royon, Christophe, William d’Assignies D., Florian Gautier, Tommaso Isidori, Nicola Minafra, and Alexander Novikov. "Fast Timing Detectors and Applications in Cosmic Ray Physics and Medical Science." Instruments 7, no. 2 (2023): 14. http://dx.doi.org/10.3390/instruments7020014.

Full text
Abstract:
We use fast silicon detectors and the fast sampling method originally developed for high energy physics for two applications: cosmic ray measurements in collaboration with NASA and dose measurements during flash beam cancer treatment. The cosmic ray measurement will benefit from the fast sampling method to measure the Bragg peak where the particle stops in the silicon detector and the dose measurement is performed by counting the number of particles that enter the detector.
APA, Harvard, Vancouver, ISO, and other styles
10

PAVLOVIČ, MÁRIUS, KATARÍNA SEDLAČKOVÁ, ANDREA ŠAGÁTOVÁ, and IVAN STRAŠÍK. "APPLICATION OF THE S3M AND MCNPX CODES IN PARTICLE DETECTOR DEVELOPMENT." International Journal of Modern Physics: Conference Series 27 (January 2014): 1460153. http://dx.doi.org/10.1142/s2010194514601537.

Full text
Abstract:
Semiconductor detectors can be used to detect neutrons if they are covered by a conversion layer. Some neutrons transfer their kinetic energy to hydrogen via elastic nuclear scattering in the conversion layer, and protons are produced as recoils. These protons enter the sensitive volume of the detector and are detected. In the process of detector development, Monte Carlo computer codes are necessary to simulate the detection process. This paper presents the main features of the S3M code (SRIM Supporting Software Modules) and shows its application potential. Examples are given for the neutron d
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Particle beam detectors"

1

Nellist, Clara. "Characterisation and beam test data analysis of 3D silicon pixel detectors for the ATLAS upgrade." Thesis, University of Manchester, 2013. https://www.research.manchester.ac.uk/portal/en/theses/characterisation-and-beam-test-data-analysis-of-3d-silicon-pixel-detectors-for-the-atlas-upgrade(22a82583-5588-4675-af5c-c3595b4ceb38).html.

Full text
Abstract:
3D silicon pixel detectors are a novel technology where the electrodes penetrate the sili- con bulk perpendicularly to the wafer surface. As a consequence the collection distance is decoupled from the wafer thickness resulting in a radiation hard pixel detector by design. Between 2010 and 2012, 3D silicon pixel detectors have undergone an intensive programme of beam test experiments. As a result, 3D silicon has successfully qualified for the ATLAS upgrade project, the Insertable B-Layer (IBL), which will be installed in the long-shutdown in 2013-14. This thesis presents selected results from t
APA, Harvard, Vancouver, ISO, and other styles
2

Ikram, M. "Radio-frequency generation of an electron plasma in a Malmberg-Penning trap and its interaction with a stationary or pulsed electron beam." Doctoral thesis, Università degli Studi di Milano, 2014. http://hdl.handle.net/2434/233616.

Full text
Abstract:
Experiments and numerical investigations on trapped electron plasmas and traveling electron bunches are discussed. A Thomson backscattering diagnostics set up was installed in the ELTRAP (Electron TRAP) device, a Penning-Malmberg trap operating at the Department of Physics of the University of Milano since 2001. Here, an infrared (IR) laser pulse collides with nanosecond electron bunches with an energy of 1-20 keV traveling through a longitudinal magnetic field in a dynamical regime where space-charge effects play a significant role. The backscattered radiation is optically filtered and detec
APA, Harvard, Vancouver, ISO, and other styles
3

Sirvent, Blasco Jose Luis. "Beam Secondary Shower Acquisition Design for the CERN High Accuracy Wire Scanner." Doctoral thesis, Universitat de Barcelona, 2019. http://hdl.handle.net/10803/666139.

Full text
Abstract:
The LHC injectors upgrade (LIU) project aims to boost the LHC luminosity by doubling the beam brightness with the construction of the new LINAC4, the first linear accelerator on the LHC chain. The brighter beams require upgrades on the full injector chain to deliver low emittance beams for the future High-Luminosity LHC (H-LHC). Thus, new and more precise beam instrumentation is under development to operate on this new scenario. These upgrades include the development of a new beam wire scanners generation (LIU-BWS), interceptive beam profile monitors used for the beam emittance calculation. Wi
APA, Harvard, Vancouver, ISO, and other styles
4

Liprandi, Silvia [Verfasser], and Peter [Akademischer Betreuer] Thirolf. "Development and performance evaluation of detectors in a Compton camera arrangement for ion beam range monitoring in particle therapy / Silvia Liprandi ; Betreuer: Peter Thirolf." München : Universitätsbibliothek der Ludwig-Maximilians-Universität, 2018. http://d-nb.info/1199265233/34.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Alarcón, Díez Víctor. "Development of charged particle detection systems for materials analysis with rapid ion beams : large solid angle detectors and numerical nuclear pulse processing." Thesis, Paris 6, 2016. http://www.theses.fr/2016PA066489/document.

Full text
Abstract:
Cette thèse présente de nouveaux développements en détection de particules chargées et traitement tout-numérique d'impulsions pour application à l'analyse avec des faisceaux d'ions rapides (IBA). Un ensemble de 16 détecteurs gravés sur une puce de Si est mis en œuvre, ce qui fournit un angle solide de détection environ 100 fois plus grande que celle des détecteurs utilisés auparavant pour l'IBA. Seize chaines d'acquisition sont également mises en œuvre avec une approche 'tout-numérique' pour le traitement des signaux issus des détecteurs. Dans son ensemble, le système ainsi développé a une rés
APA, Harvard, Vancouver, ISO, and other styles
6

Alarcón, Díez Víctor. "Development of charged particle detection systems for materials analysis with rapid ion beams : large solid angle detectors and numerical nuclear pulse processing." Electronic Thesis or Diss., Paris 6, 2016. http://www.theses.fr/2016PA066489.

Full text
Abstract:
Cette thèse présente de nouveaux développements en détection de particules chargées et traitement tout-numérique d'impulsions pour application à l'analyse avec des faisceaux d'ions rapides (IBA). Un ensemble de 16 détecteurs gravés sur une puce de Si est mis en œuvre, ce qui fournit un angle solide de détection environ 100 fois plus grande que celle des détecteurs utilisés auparavant pour l'IBA. Seize chaines d'acquisition sont également mises en œuvre avec une approche 'tout-numérique' pour le traitement des signaux issus des détecteurs. Dans son ensemble, le système ainsi développé a une rés
APA, Harvard, Vancouver, ISO, and other styles
7

Branger, Erik. "Development of a Beam Loss Monitoring system for CTF-3 TBL." Thesis, Linköpings universitet, Institutionen för fysik, kemi och biologi, 2013. http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-97645.

Full text
Abstract:
The Compact Linear Collider (CLIC) study is a feasibility study for a new linear accelerator that aims to reach a center-of-mass collision energy of 3 TeV. To keep the length of the accelerator reasonable, a high accelerating gradient of 100 MeV/m is provided by a novel acceleration scheme, where power is extracted from a high-intensity drive beam to accelerate a high-energy main beam. The Test Beam Line (TBL) at the CLIC Test Facility 3 (CTF-3) is an experimental beamline constructed to test the technology for deceleration and power extraction of the drive beam. A Beam Loss Monitoring (BLM) s
APA, Harvard, Vancouver, ISO, and other styles
8

Cullen, Ashley James. "Strip detector for high spatial resolution dosimetry in radiation therapy." Centre for Medical Radiation Physics - Faculty of Engineering, 2009. http://ro.uow.edu.au/theses/848.

Full text
Abstract:
Radiation therapy is an established modality in the treatment of tumours. With treatments ever evolving and increasing in terms of their complexities, the need arises to ensure the best quality treatment is delivered; the survival of the patient relies upon it. A modern treatment such as Intensity Modulated Radiation Therapy employs steep dose gradients varying dynamically to deliver complex dose profiles, whilst the experimental Microbeam Radiation Therapy (MRT) involves the delivery of an array of intense beams tens-of-microns wide separated by several hundred microns. In both cases, convent
APA, Harvard, Vancouver, ISO, and other styles
9

Polesello, Giacomo. "A Search for vmu <->vttau oscillations at the CERN SPS neutrino beam with the NOMAD detector." Paris 7, 1999. http://www.theses.fr/1999PA077206.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Caravaca, Rodríguez Javier. "Measurement of the electron-neutrino component of the T2K beam and search for electron-neutrino disappearance at the T2K Near Detector." Doctoral thesis, Universitat Autònoma de Barcelona, 2014. http://hdl.handle.net/10803/283399.

Full text
Abstract:
T2K es un experimento de oscilaciones de neutrinos de largo recorrido en el que por primera vez se ha observado la aparición de neutrinos electrónicos en un haz de neutrinos muónicos. Así pues, el único ángulo de mezcla que quedaba por conocer, q13, es medido con gran precisión. el background principal de esta medida es la contaminación de neutrinos electrónicos producida en el haz junto con la componente de neutrinos muónicos. Ésta es una componente irreducible que ha de ser medida y controlada. La componente intrínseca de neutrinos electrónicos es medida antes de las oscilaciones en el
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Particle beam detectors"

1

service), SpringerLink (Online, ed. Model of the Response Function of CUORE Bolometers. Springer Science+Business Media B.V., 2011.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Workshop on Electronuclear Physics with Internal Targets and the BLAST Detector (1992 Arizona State University). Electronuclear physics with internal targets and the BLAST detector: Workshop on Electronuclear Physics with Internal Targets and the BLAST Detector, Arizona, USA, March 19-21, 1992. Edited by Alarcon Ricardo and Butler Malcolm. World Scientific, 1993.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Ricardo, Alarcon, and Milner Richard, eds. Proceedings of the Second Workshop on Electronuclear Physics with Internal Targets and the BLAST Detector. World Scientific, 1999.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
4

Rossi, Leonardo, Tilman Rohe, Norbert Wermes, and Peter Fischer. Pixel Detectors: From Fundamentals to Applications. Springer, 2010.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Pixel Detectors: From Fundamentals to Applications (Particle Acceleration and Detection). Springer, 2006.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

Vignati, Marco. Model of the Response Function of CUORE Bolometers. Springer Netherlands, 2016.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Caminada, Lea. Study of the Inclusive Beauty Production at CMS and Construction and Commissioning of the CMS Pixel Barrel Detector. Springer, 2014.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
8

(Editor), Richard Milner, and Ricardo Alarcon (Editor), eds. Proceedings of the 2nd Workshop on Electro-Nuclear Physics With Internal Targets and Blast Detector. World Scientific Publishing Company, 1999.

Find full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Particle beam detectors"

1

Windischhofer, Philipp. "In-Beam Performance of Single-Photon Avalanche Diodes." In Physics for Particle Detectors and Particle Detectors for Physics. Springer Nature Switzerland, 2023. http://dx.doi.org/10.1007/978-3-031-39055-5_5.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Minty, Michiko G., and Frank Zimmermann. "Collimation." In Particle Acceleration and Detection. Springer Berlin Heidelberg, 2003. http://dx.doi.org/10.1007/978-3-662-08581-3_6.

Full text
Abstract:
AbstractParticles at large betatron amplitudes or with a large momentum error constitute what is generally referred to as a beam halo. Such particles are undesirable since they produce a background in the particle-physics detector. The background arises either when the halo particles are lost at aperture restrictions in the vicinity of the detector, producing electro-magentic shower or muons, or when they emit synchrotron radiation that is not shielded and may hit sensitive detector components. In superconducting hadron storage rings, a further concern is localized particle loss near one of th
APA, Harvard, Vancouver, ISO, and other styles
3

Méot, François. "Spectrometer; Mass Separator." In Particle Acceleration and Detection. Springer International Publishing, 2024. http://dx.doi.org/10.1007/978-3-031-59979-8_13.

Full text
Abstract:
AbstractThis chapter is an introduction to nuclear physics spectrometer and mass separator optical systems. Optical specificities are discussed, leaning on concepts and on theoretical material introduced in earlier chapters, or found in Optical Elements and Keywords (Chap. 14). The chapter begins with a brief overview of mass separation techniques and their use, and continues with a reminder of underlying beam optics principles. The simulation of mass separation requires essentially three optical elements from library. DIPOLE[S] which allows for curved EFBs and field index; it also allows seve
APA, Harvard, Vancouver, ISO, and other styles
4

Kirkby, Jasper. "Detectors for ø, τ-charm and B Factories." In Frontiers of Particle Beams: Factories with e+ e- Rings. Springer Berlin Heidelberg, 1994. http://dx.doi.org/10.1007/978-3-662-13972-1_20.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Mobit, P. N., and G. A. Sandison. "Is the Spencer-Attix Cavity Equation Applicable for Solid-State Detectors Irradiated in Megavoltage Electron Beams?" In Advanced Monte Carlo for Radiation Physics, Particle Transport Simulation and Applications. Springer Berlin Heidelberg, 2001. http://dx.doi.org/10.1007/978-3-642-18211-2_48.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

"Development of accurate dosimetry SiPM-based detectors for FLASH RT." In Book of Abstracts - RAD 2025 Conference. RAD Centre, Niš, Serbia, 2025. https://doi.org/10.21175/rad.abstr.book.2025.33.2.

Full text
Abstract:
FLASH radiotherapy and particle therapy are performed using ultra-high dose rate radiation (UHDR), specifically a dose rate higher than 40 Gy/sec. The advantage of FLASH compared to conventional therapy (CT) is based on the FLASH effect: improved normal tissue sparing while still maintaining tumor control. Accurate dosimetry and real-time beam monitoring are critical for its clinical translation, but current detectors suffer from saturation effects in the signal production and signal read-out when dealing with UHDR beams. We report on our development and preliminary tests a novel dosimeter for
APA, Harvard, Vancouver, ISO, and other styles
7

MARTIŠÍKOVÁ, M., B. HARTMANN, O. JÄKEL, C. GRANJA, and J. JAKUBEK. "PERSPECTIVES OF THE PIXEL DETECTOR TIMEPIX FOR NEEDS OF ION BEAM THERAPY." In Astroparticle, Particle, Space Physics, Radiation Interaction, Detectors and Medical Physics Applications. WORLD SCIENTIFIC, 2012. http://dx.doi.org/10.1142/9789814405072_0091.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

ANTONELLI, M., A. TALLAIRE, J. ACHARD, et al. "BUNCH BY BUNCH X-RAY BEAM POSITION AND INTENSITY MONITORING USING A SINGLE CRYSTAL DIAMOND DETECTOR." In Astroparticle, Particle, Space Physics, Radiation Interaction, Detectors and Medical Physics Applications. WORLD SCIENTIFIC, 2012. http://dx.doi.org/10.1142/9789814405072_0123.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

ABBANEO, D., S. BALLY, H. POSTEMA, et al. "A DEDICATED BEAM TESTS OF THE FULL-SCALE PROTOTYPE OF GEMS FOR CMS IN A STRONG MAGNETIC FIELD." In Astroparticle, Particle, Space Physics, Radiation Interaction, Detectors and Medical Physics Applications. WORLD SCIENTIFIC, 2012. http://dx.doi.org/10.1142/9789814405072_0109.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

KIRYUNIN, A. E., and P. STRIZENEC. "VALIDATION OF THE LOCAL HADRONIC CALIBRATION SCHEME OF ATLAS WITH COMBINED BEAM TEST DATA IN THE ENDCAP AND FORWARD REGIONS OF ATLAS." In Astroparticle, Particle, Space Physics, Radiation Interaction, Detectors and Medical Physics Applications. WORLD SCIENTIFIC, 2012. http://dx.doi.org/10.1142/9789814405072_0121.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Particle beam detectors"

1

Craplet, Alie. "Sub-GeV particle identification with aerogel Cherenkov threshold detectors and tagged photon beam for the Water Cherenkov Test Experiment." In 42nd International Conference on High Energy Physics. Sissa Medialab, 2024. https://doi.org/10.22323/1.476.1114.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Ono, Keita. "In-beam charged particle detector using 0.2-mm thick plastic scintillator for the J-PARC KOTO experiment." In 42nd International Conference on High Energy Physics. Sissa Medialab, 2024. https://doi.org/10.22323/1.476.0969.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Rovelli, A., G. Ciavola, G. Cuttone, et al. "Low-intensity beam diagnostics with particle detectors." In Beam instrumentation. AIP, 1997. http://dx.doi.org/10.1063/1.52296.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

ERICH, Griesmayer. "Diamond Detectors for beam instrumentation." In Technology and Instrumentation in Particle Physics 2014. Sissa Medialab, 2015. http://dx.doi.org/10.22323/1.213.0088.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Barschel, Colin. "Beam profile measurements based on modern vertex detectors and beam-gas interactions." In Technology and Instrumentation in Particle Physics 2014. Sissa Medialab, 2015. http://dx.doi.org/10.22323/1.213.0084.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Finocchiaro, P. "Particle detectors for low intensity ion beam diagnostics." In The fifteenth international conference on the application of accelerators in research and industry. AIP, 1999. http://dx.doi.org/10.1063/1.59060.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Kye-Ryung Kim, Yong-Sub Cho, In-Seok Hong, et al. "Proton beam energy measurement using semiconductor detectors at the 45MeV test beam line of PEFP." In 2007 IEEE Particle Accelerator Conference. IEEE, 2007. http://dx.doi.org/10.1109/pac.2007.4439969.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Walsh, S., C. Buttar, P. Sellin, D. Morgan, C. Hardingham, and J. Burrage. "Characterisation and preliminary analysis of the 1996 GaAs keystone test beam detectors." In Instrumentation in elementary particle physics. AIP, 1998. http://dx.doi.org/10.1063/1.55067.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Arcidiacono, Roberta, Nicolo Cartiglia, Francesca Cenna, et al. "Laboratory and Beam Test Results of TOFFEE ASIC and Ultra Fast Silicon Detectors." In Topical Workshop on Electronics for Particle Physics. Sissa Medialab, 2018. http://dx.doi.org/10.22323/1.313.0028.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Olivier Dadoun and Philip Bambade. "Backscattering of secondary particles into the ILC detectors from beam losses along the extraction lines." In 2007 IEEE Particle Accelerator Conference (PAC). IEEE, 2007. http://dx.doi.org/10.1109/pac.2007.4440555.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Particle beam detectors"

1

Tanthapanichakoon, Wiwut. Development of phase doppler anemometer for measuring velocity and size distribution of paticulate materials. Chulalongkorn University, 2004. https://doi.org/10.58837/chula.res.2004.72.

Full text
Abstract:
Particle size analysis is an essential analytical task in a large variety of processes of industrial and laboratorial relevance. Phase doppler anemometer (PDA) is one of well-established techniques allowing simultaneous measurement of velocity and size of particles, droplets, or bubbles in two-phase flows including spray atomization. The method is based upon the principle of light scattering interferometry. When a particle passes through the probe volume defined by the intersection of two laser beams, the phase of the light scattered by the particle carries information about the particle size,
APA, Harvard, Vancouver, ISO, and other styles
2

Palni, Prabhakar. Evidence for the Heavy Baryon Resonance State $\Lambda_{b}^{\ast0}$ Observed with the CDF II Detector, and Studies of New Particle Tracking Technologies Using the LANSCE Proton Beam. Office of Scientific and Technical Information (OSTI), 2014. http://dx.doi.org/10.2172/1128847.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!