Academic literature on the topic 'Probe-forming system'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Probe-forming system.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Probe-forming system"

1

Lebed, S. A. "A two-regime probe-forming system for modern nuclear nanoprobes." Technical Physics 47, no. 1 (2002): 88–91. http://dx.doi.org/10.1134/1.1435895.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Wen, Jianguo, James Mabon, Changhui Lei, et al. "The Formation and Utility of Sub-Angstrom to Nanometer-Sized Electron Probes in the Aberration-Corrected Transmission Electron Microscope at the University of Illinois." Microscopy and Microanalysis 16, no. 2 (2010): 183–93. http://dx.doi.org/10.1017/s1431927610000085.

Full text
Abstract:
AbstractWe evaluate the probe forming capability of a JEOL 2200FS transmission electron microscope equipped with a spherical aberration (Cs) probe corrector. The achievement of a real space sub-Angstrom (0.1 nm) probe for scanning transmission electron microscopy (STEM) imaging is demonstrated by acquisition and modeling of high-angle annular dark-field STEM images. We show that by optimizing the illumination system, large probe currents and large collection angles for electron energy loss spectroscopy (EELS) can be combined to yield EELS fine structure data spatially resolved to the atomic sc
APA, Harvard, Vancouver, ISO, and other styles
3

Shao, Zhifeng. "On the fifth order aberration in a sextupole corrected probe forming system." Review of Scientific Instruments 59, no. 11 (1988): 2429–37. http://dx.doi.org/10.1063/1.1139922.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Magilin, D. V., A. G. Ponomarev, V. A. Rebrov, et al. "Performance of the Sumy nuclear microprobe with the integrated probe-forming system." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 267, no. 12-13 (2009): 2046–49. http://dx.doi.org/10.1016/j.nimb.2009.03.015.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Jamieson, D. N., C. G. Ryan, and S. H. Sie. "Measurement of the aberrations of an electrostatic quadrupole probe forming lens system." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 54, no. 1-3 (1991): 33–37. http://dx.doi.org/10.1016/0168-583x(91)95486-w.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Ponomarev, A. G., G. S. Vorobjov, and A. A. Ponomarova. "Optimization of the quadrupole probe-forming system with individual power supplies for lenses." Radioelectronics and Communications Systems 53, no. 2 (2010): 113–18. http://dx.doi.org/10.3103/s0735272710020068.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Ignat’ev, I. G., D. V. Magilin, V. I. Miroshnichenko, A. G. Ponomarev, V. E. Storizhko, and B. Sulkio-Cleff. "Immersion probe-forming system as a way to the compact design of nuclear microprobe." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 231, no. 1-4 (2005): 94–100. http://dx.doi.org/10.1016/j.nimb.2005.01.040.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Breese, M. B. H., D. N. Jamieson, and B. L. Doyle. "The use of solenoid lenses in a two-stage nuclear microprobe probe-forming system." Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 188, no. 1-4 (2002): 261–66. http://dx.doi.org/10.1016/s0168-583x(01)01110-7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Matsuya, M., M. Saito, C. H. Nielsen, and S. Nakagawa. "The Large Depth of Focus (LDF) Mode in 3-Stage Lens System." Proceedings, annual meeting, Electron Microscopy Society of America 49 (August 1991): 990–91. http://dx.doi.org/10.1017/s0424820100089263.

Full text
Abstract:
The Large Depth of Focus (hereinafter abbreviated to LDF) mode has been developed. The depth of focus in the LDF mode has been made 3 to 5 times larger than that in a conventional probe forming system by changing the positions of imaging points in the 3-stage lens system. The LDF mode has been applied successfully to observing the specimen with a large height difference (2 mm) without defocus and to analyzing it by EDS.
APA, Harvard, Vancouver, ISO, and other styles
10

Sawada, Hidetaka, Christopher S. Allen, Shanshan Wang, Jamie H. Warner, and Angus I. Kirkland. "Aberration measurement of the probe-forming system of an electron microscope using two-dimensional materials." Ultramicroscopy 182 (November 2017): 195–204. http://dx.doi.org/10.1016/j.ultramic.2017.06.024.

Full text
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Probe-forming system"

1

Пономарьова, Ганна Олександрівна, Анна Александровна Пономарева та Hanna Oleksandrivna Ponomarova. "Квадрупольные зондоформирующие системы со свободными параметрами фокусирующих полей". Thesis, СумГУ, 2013. http://essuir.sumdu.edu.ua/handle/123456789/33748.

Full text
Abstract:
Дисертаційна робота присвячена визначенню впливу вільних параметрів фокусуючих полів на густину струму в зонді для систем формування прецизійних пучків іонів МеВ-х енергій у ядерному скануючому мікрозонді (ЯСМЗ). Як вільні параметри запропоновані додаткові джерела живлення магнітних квадрупольних лінз і кути конусності апертури. Результати проведеного числового моделювання зондоформуючої системи (ЗФС) на базі мультиплетів магнітних квадрупольних лінз (МКЛ) показали, що оптимізація процесу формування пучка з додатковими джерелами живлення лінз, яка ґрунтується на знаходженні найбільшого зведено
APA, Harvard, Vancouver, ISO, and other styles

Books on the topic "Probe-forming system"

1

Grime, G. W., and F. Watt. Beam Optics of Quadruple Probe-Forming Systems. Adam Hilger, 1985.

Find full text
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Probe-forming system"

1

Binder, Thomas. "Technical equipment for echocardiography." In ESC CardioMed, edited by Frank Flachskampf. Oxford University Press, 2018. http://dx.doi.org/10.1093/med/9780198784906.003.0084.

Full text
Abstract:
Advances in ultrasound technology are shaping the way we apply echocardiography today. The industry has now developed a vast array of scanners that are targeted to different clinical requirements, budgets, and applications. In general, they can be categorized into high-end, mid-range, portable, and handheld scanners. Aside from image quality, much emphasis is placed on ergonomics, the user interface, and the patient data archiving system, which are all important to optimize workflow. Phased array transducers are used in echocardiography. Much of the signal processing (i.e. beam forming) occurs
APA, Harvard, Vancouver, ISO, and other styles
2

Szielasko Klaus, Youssef Sargon, Niese Frank, et al. "Multi-Method Probe Design for the Electromagnetic Characterization of Advanced High Strength Steel." In Studies in Applied Electromagnetics and Mechanics. IOS Press, 2014. https://doi.org/10.3233/978-1-61499-407-7-52.

Full text
Abstract:
Electromagnetic non-destructive testing (NDT) systems have been used in steel strip production lines for a long time. Indirect electromagnetic determination of approximate yield and ultimate strength values can be considered state of the art. However, the excellent mechanical properties of advanced high strength steel (AHSS) are particularly sensitive to process variations. Characteristics and homogeneity of texture, grain size and secondary phase content are crucial during forming and welding of steel strips. Ultrasonic methods can be applied in order to indirectly characterize these properti
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Probe-forming system"

1

Callon, R. "Cathodic Protection of Concrete Caissons and Deck of a Ship Repair Yard." In CORROSION 2016. NACE International, 2016. https://doi.org/10.5006/c2016-07175.

Full text
Abstract:
Abstract Two types of impressed current cathodic protection and a sacrificial method were used to protect over 100,000m2 of reinforced concrete caissons and deck slab of a new ship repair yard. The structures comprised of 53 caissons weighing 4,000 tonnes each forming over 2km of quays and piers. The specification required that the systems were monitored using Reference Electrodes and current pick up probes. All current adjustments and monitoring was carried out from one central location. This paper describes the CP and monitoring systems used and compares the monitoring results from the diffe
APA, Harvard, Vancouver, ISO, and other styles
2

Chen, Yongxu, Tesfaalem Haile, Peyman Derik Vand, and John Wolodko. "Detection of Biofilm Forming Microbes Using Electrochemical Methods." In CORROSION 2020. NACE International, 2020. https://doi.org/10.5006/c2020-15087.

Full text
Abstract:
Abstract Microbiologically Influenced Corrosion (MIC) and biofouling are major challenges to operators who manage water systems in the oil & gas and other sectors. Key to these threats is the formation and accumulation of biofilms in piping systems due to the agglomeration of both biotic components (e.g. microorganisms such as bacteria, archea and extracellular polymeric substances) and abiotic materials (e.g. inorganic solids). These biofilms adhere to inner pipe wall surfaces, and evolve over time depending on surrounding environmental conditions. Manual detection of biofilm formation an
APA, Harvard, Vancouver, ISO, and other styles
3

Sun, Wei, Srdjan Nesic, and Sankara Papavinasam. "Kinetics of Iron Sulfide and Mixed Iron Sulfide/Carbonate Scale Precipitation in CO2/H2S Corrosion." In CORROSION 2006. NACE International, 2006. https://doi.org/10.5006/c2006-06644.

Full text
Abstract:
Abstract Glass cell experiments were conducted to investigate kinetics of iron sulfide and mixed iron sulfide/carbonate scale precipitation in CO2/H2S corrosion. Weight gain/loss (WGL) method was used to investigate the scale formation using X65 carbon steel as substrates. Scanning Electron Microscopy (SEM/EDS), X-ray Diffraction methodology (XRD), X-ray Photoelectron Spectroscopy (XPS), and Electron Probe Micro-analyzer (EPMA) were used to analyse the scale. The experimental results show that the corrosion products formed in CO2/H2S system depend on the competitiveness of iron carbonate and m
APA, Harvard, Vancouver, ISO, and other styles
4

Frail, Paul R., Reza Sharghi-Moshtaghin, Gilad Zorn, and Martin M. Morra. "Elucidating the Differences between Weight Loss and Instantaneous Corrosion Rates for Azole Films on Copper Metallurgy." In CORROSION 2015. NACE International, 2015. https://doi.org/10.5006/c2015-05924.

Full text
Abstract:
Abstract Water systems with mixed metallurgies require proper low carbon steel and copper alloy metal corrosion control. Improper copper corrosion control can lead to failure of copper alloys, such as admiralty brass metal within the system and cause galvanic corrosion on less noble metal, like carbon steel and cast iron. Azoles, benzotriazole (BZT) and tolyltriazole (TTA), are generally used to control copper corrosion in heat exchangers that are employed in open recirculation cooling tower systems, via a film forming mechanism on the metal surface. Monitoring of corrosion control can be done
APA, Harvard, Vancouver, ISO, and other styles
5

Feasey, N. D., R. J. Wintle, E. R. Freiter, and M. M. Jordan. "Field Experiences with a Novel near Real Time Monitor for Scale Deposition in Oilfield Systems." In CORROSION 2000. NACE International, 2000. https://doi.org/10.5006/c2000-00117.

Full text
Abstract:
Abstract Mineral scale deposition is a well-known problem for the petroleum industry. The application of scale inhibitors can often prevent such deposits forming, but assessment of the concentrations of these needed for control has relied on indirect methods for assessing brine stability. Such methods use laboratory tests and measurement of scale inhibitor residuals. Recently a new technique for direct measurement of the stability of oilfield brines has been developed. This technique uses TSMR (Thickness Shear Mode Resonator) technology. Deposition on the probe alters resonant frequency, measu
APA, Harvard, Vancouver, ISO, and other styles
6

Ponomarova, A. A., G. S. Vorobjov, and I. V. Barsuk. "Comparison of the ion-optical characteristics of conventional quadrupole probe-forming lenses in the nuclear scanning microprobe system." In 2014 24th International Crimean Conference "Microwave & Telecommunication Technology" (CriMiCo). IEEE, 2014. http://dx.doi.org/10.1109/crmico.2014.6959612.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Tatum, Jim A., and Duncan L. MacFarlane. "Induced ultrafast phenomena in InGaAIP lasers." In OSA Annual Meeting. Optica Publishing Group, 1991. http://dx.doi.org/10.1364/oam.1991.mg2.

Full text
Abstract:
We study the ultrafast gain dynamics of visible wavelength InGaAIP semiconductor diode lasers. Our experimental configuration makes use of an ultrafast dye laser system that produces a train of pulses forming a suitable signal with which to probe these diode lasers. When the pulse train is coupled into the active region of the diode laser, we observe a phase locking of a self-induced oscillation in the diode laser to the dye laser pulse train. This locking extends over a large range of probe wavelengths. In addition to this entrainment, we observe the gain recovery dynamics of the diode laser,
APA, Harvard, Vancouver, ISO, and other styles
8

Taylor, Graham, and Andy Sarles. "Feedback Controlled Bilayer Heating Within the Regulated Attachment Method." In ASME 2013 Conference on Smart Materials, Adaptive Structures and Intelligent Systems. American Society of Mechanical Engineers, 2013. http://dx.doi.org/10.1115/smasis2013-3132.

Full text
Abstract:
Synthetic lipid bilayers provide a cell-inspired environment for studying the functions of biomolecules. The regulated attachment method (RAM) is one method for forming liquid-supported lipid bilayers — known as droplet interface bilayers (DIBs) — that form at the interface of lipid-encased aqueous volumes in oil. While RAM allows for independent control of the aqueous phases on both sides of the membrane and provides a convenient way to control the size of the bilayer, previous studies utilizing this technique have been performed exclusively at room temperature. The goal of this research is t
APA, Harvard, Vancouver, ISO, and other styles
9

Hager, J. M., S. Simmons, D. Smith, S. Onishi, L. W. Langley, and T. E. Diller. "Experimental Performance of a Heat Flux Microsensor." In ASME 1990 International Gas Turbine and Aeroengine Congress and Exposition. American Society of Mechanical Engineers, 1990. http://dx.doi.org/10.1115/90-gt-256.

Full text
Abstract:
The performance characteristics of a heat flux microsensor have been measured and analyzed. This is a new heat flux gage system that is made using microfabrication techniques. The gages are small, have high frequency response, can measure very high heat flux, and output a voltage directly proportional to the heat flux. Each gage consists of a thin thermal resistance layer sandwiched between many thermocouple pairs forming a differential thermopile. Because the gage is made directly on the measurement surface and the total thickness is less than 2µm, the presence of the gage contributes negligi
APA, Harvard, Vancouver, ISO, and other styles
10

Dymnikov, Alexander D., Gary A. Glass, Floyd D. McDaniel, and Barney L. Doyle. "Comparison Of Electromagnetic, Electrostatic And Permanent Magnet Quadrupole Lens Probe-Forming Systems For High Energy Ions." In APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY: Twenty-First International Conference. AIP, 2011. http://dx.doi.org/10.1063/1.3586097.

Full text
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!