Academic literature on the topic 'Water Level Sensor'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the lists of relevant articles, books, theses, conference reports, and other scholarly sources on the topic 'Water Level Sensor.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Journal articles on the topic "Water Level Sensor"

1

Wister, Miguel A., Ernesto Leon, Alejandro Alejandro-Carrillo, Pablo Pancardo, and Jose A. Hernandez-Nolasco. "Using IoT for Cistern and Water Tank Level Monitoring." Applied System Innovation 7, no. 6 (2024): 112. http://dx.doi.org/10.3390/asi7060112.

Full text
Abstract:
This paper proposes an experimental design to publish online the measurements obtained from four sensors: one sensor inside a cistern measures the level of drinking water, another sensor in a water tank monitors its level, a third sensor measures water flow or pressure from the pipes, and a fourth sensor assesses water quality. Several tank filling and emptying tests were performed. Experimental results demonstrated that if the cistern perceived that there was no water in the tank, it turned on the water pump to fill the tank to 100% of its storage capacity; while this was happening, the water
APA, Harvard, Vancouver, ISO, and other styles
2

Rizqi Satrio, Nur, Bima Romadhon Parada Dian Palevi, and Michael Ardita. "Perancangan Sensor Water Level Menggunakan Nirkabel." Jurnal FORTECH 6, no. 1 (2025): 30–41. https://doi.org/10.56795/fortech.v6i1.6105.

Full text
Abstract:
The design of the wireless water level sensor system aims to monitor water in the river effectively and efficiently. The system utilizes wireless technology to transmit data in real-time, allowing users to monitor water levels remotely. In this project, the water level sensor was selected for its high accuracy in measuring the depth of the water. The data collected by the sensors will be transmitted via a wireless communication module such as LoRa that we use to a web-based application or mobile device, where the user can visually monitor the status of the water level. The system test method i
APA, Harvard, Vancouver, ISO, and other styles
3

Salami, Ifedapo Abdullahi, Hadi Habaebi Mohamed, and Abdul Malik Noreha. "Capacitive electrode sensor implanted on a printed circuit board designed for continuous water level measurement." Bulletin of Electrical Engineering and Informatics 8, no. 2 (2019): 450–59. https://doi.org/10.11591/eei.v8i2.1515.

Full text
Abstract:
Water level sensors are one of the practical ways to get the actual measurement of the depth of a dam or canal. The ease of deployment and easy data acquisition makes them widely used in many fields. Therefore, it will be advantageous to have a miniaturized water level sensor for easier mobility and deployment. A novel method for measuring water level using a Printed Circuit Board has been proposed in this paper. The design stages of circuit sketching, printing of sketch on PCB and etching are discussed for the electrode water level sensor. A signal conditioning circuit is necessary to maintai
APA, Harvard, Vancouver, ISO, and other styles
4

Pereira, G. S., R. C. Ramirez, E. S. Agulto, and V. B. Ella. "Performance evaluation of a water level sensor under various turbidity levels in lowland crop production systems." IOP Conference Series: Earth and Environmental Science 1038, no. 1 (2022): 012033. http://dx.doi.org/10.1088/1755-1315/1038/1/012033.

Full text
Abstract:
Abstract The practice of alternate wetting and drying (AWD), a water-saving technology in lowland crop production systems, can be greatly facilitated using wireless water level sensors. However, these sensors generally work under clear water conditions. The sensitivity of these sensors to turbidity is important for accurate water level measurement and appropriate irrigation scheduling. This study evaluated the performance of a high-end water level sensor of the submersible pressure transducer type under various turbidity levels. The performance tests were performed in the laboratory using wate
APA, Harvard, Vancouver, ISO, and other styles
5

Mazratul, Firdaus Mohd Zin, Zuhri Kamal Farid, Izawana Ismail Syila, Siti Syahidah Ku Mohd Noh Ku, and Hafiz Kassim Abdul. "Development of dam controller technology water level and alert system using Arduino UNO." Development of dam controller technology water level and alert system using Arduino UNO 31, no. 3 (2023): 1342–49. https://doi.org/10.11591/ijeecs.v31.i3.pp1342-1349.

Full text
Abstract:
Recently, various water level detection monitoring systems integrations were implemented to various places such as rivers and reservoirs to avoid floods. Thus, it is determined to construct a project primarily focused on water level management, named dam controller technology (DCOTech). DCOTech is a system that controls the amount of water in a reservoir using a microcontroller ATMEGA328p and several functions to prevent flash floods. Water sustainability requires proper monitoring via sensors and a controller. Moreover, a buzzer is used in DCOTech to give a warning signal to the people around
APA, Harvard, Vancouver, ISO, and other styles
6

Indrasari, W., and L. V. Kadarwati. "Prototype of water level monitoring system using magnetic sensor and ultrasonic based on Arduino Mega 2560." Journal of Physics: Conference Series 2193, no. 1 (2022): 012052. http://dx.doi.org/10.1088/1742-6596/2193/1/012052.

Full text
Abstract:
Abstract Water level monitoring is an activity to observe the water level by identifying and anticipating flood problems that will arise for action to be taken as early as possible. This system is connected by water level measurement. This prototype uses two types of sensors to measure the water level, the UGN3503 magnetic sensor will detect the water level horizontally, and ultrasonic sensors will detect vertically. Arduino Mega 2560, as a control system, regulates the work of the integrated sensors. The experiment using one UGN3503 sensor is obtained the maximum deviation on the addition or
APA, Harvard, Vancouver, ISO, and other styles
7

Reddy, Mr P. Obula, T. S. Sabiha, S. Reshma, S. .Rajkumar, and ,K Venkata Sai Chaitanya Kumar. "Smart Water Level Monitoring and Prevention Using IOT." INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT 09, no. 04 (2025): 1–9. https://doi.org/10.55041/ijsrem43727.

Full text
Abstract:
Flood is a common problem not only in India but worldwide and most of the water bodies are easily accessible to common people. At times it may happen that the weather conditions may change suddenly and the water bodies may become violent, resulting in a flood which can lead to loss of lives as well as livestock. Therefore, a rapid flood detection system that can reach a wide area such as the internet is necessary to minimize the effect sof disasters. So, this paper proposes a flood detection system with the help of the Internet of Things (IoT).DHT-11 Digital Temperature and Humidity Sensor. Th
APA, Harvard, Vancouver, ISO, and other styles
8

Sihombing, Jaya, Ariep Jaenul, Sinka Wilyanti, and Nadya Putri. "Prototype of Drainage Water Level Monitoring System Using Internet of Things (IoT) Based Web." SMARTICS Journal 8, no. 2 (2022): 10–16. http://dx.doi.org/10.21067/smartics.v8i2.7559.

Full text
Abstract:
Information on water levels needs to be conveyed quickly. So, when the rainfall is high, the supervisory team that monitor the drainage water level needs to be alert move quickly to prevent losses. In addressing these problems, the author will provide a solution in Monitoring of the water level system in the drainage water reservoir so that the operator and maintenance team can find out if there is an over discharge in the drainage water reservoir when the rainfall is very high. By utilizing ultrasonic sensors to detect changes in drainage water level. The ultrasonic sensor used has better rel
APA, Harvard, Vancouver, ISO, and other styles
9

Mardhotillah, Ibnu, Rolly Yesputra, and Syartika Anggraini. "Tongkat Pintar Bagi Penyandang Disabilitas Tunanetra Berbasis Ultrasonic Dan Water Level." JUTSI (Jurnal Teknologi dan Sistem Informasi) 1, no. 3 (2021): 227–34. http://dx.doi.org/10.33330/jutsi.v1i3.1314.

Full text
Abstract:
Abstract: At this time, persons with visual impairments are divided into two, namely total blindness and those who still have residual vision, with the reduced functioning of the sense of sight, someone who is visually impaired tries to maximize the functioning of the other senses such as smell, hearing, and so forth. Based on existing conditions in the field, as well as previous research, the researchers wanted to design a tool that could help people with visual impairments. This tool system works from the design of stick-shaped devices, the electronics are placed, such as arduino, ultrasonic
APA, Harvard, Vancouver, ISO, and other styles
10

Cruz, Kristelle Marie S. Dela, Victor B. Ella, Delfin C. Suministrado, Gamiello S. Pereira, and Edzel S. Agulto. "A Low-Cost Wireless Sensor for Real-Time Monitoring of Water Level in Lowland Rice Field under Alternate Wetting and Drying Irrigation." Water 14, no. 24 (2022): 4128. http://dx.doi.org/10.3390/w14244128.

Full text
Abstract:
The use of wireless sensors for real-time monitoring of field water level would greatly facilitate the application of alternate wetting and drying (AWD), an irrigation water management technique proven to result to significant water savings and reduced methane emissions in lowland rice production systems. However, most of the commercially available wireless sensors are generally costly. This study developed a low-cost wireless sensor that can perform real-time monitoring of water depth and surface temperature in lowland rice fields under an AWD irrigation regime. The sensor is composed mainly
APA, Harvard, Vancouver, ISO, and other styles
More sources

Dissertations / Theses on the topic "Water Level Sensor"

1

Šamánek, Radek. "Posouzení časových změn přesnosti vykazovaného průtoku a proteklého objemu u měřicích systémů využívajících vzdouvací objekty." Master's thesis, Vysoké učení technické v Brně. Fakulta stavební, 2019. http://www.nusl.cz/ntk/nusl-391943.

Full text
Abstract:
The diploma thesis deals with monitoring of metrological characteristics of ultrasonic sensors located at the FAST and in-situ and the evaluation of the time development in the values of the discharge and the outflow volumes reported by the ultrasonic sensors.
APA, Harvard, Vancouver, ISO, and other styles
2

Dalkic, Yurdaer, and Zoubida Alshekhly. "Development and design of a prototype for monitoring the water level in water wells using LoRaWAN." Thesis, Malmö universitet, Fakulteten för teknik och samhälle (TS), 2018. http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-20667.

Full text
Abstract:
En översvämning kan inträffa när som helst och var som helst i världen. En översvämning börjar när vattennivån ökar, särskilt i dagvattenbrunnar i stadsområden. Genom att utnyttja de olika moderna teknologier som Internet of Things (IoT), förluster som orsakas av en översvämning kan minskas. Därför behövs en IoT-lösning för att övervaka vattennivån i brunnarna.Syftet med denna avhandling är att undersöka hur man konstruerar och implementerar ett IoT-baserat system som övervakar vattennivån för att bygga en prototyp med LoRaWAN teknologi. Konstruktionen av prototypen utförs genom att följa steg
APA, Harvard, Vancouver, ISO, and other styles
3

Бойчук, Дмитро Романович, та Dmytro Boychuk. "Розробка автоматизованого лабораторного стенду для перевіряння метрологічних характеристик давачів рівня води". Bachelor's thesis, Тернопільський національний технічний університет ім. І. Пулюя, Факультет прикладних інформаційних технологій та електроінженерії, Кафедра автоматизації технологічних процесів і виробництв, 2021. http://elartu.tntu.edu.ua/handle/lib/35485.

Full text
Abstract:
Робота виконана на кафедрі автоматизації технологічних процесів і виробництв факультету прикладних інформаційних технологій та електроінженерії Тернопільського національного технічного університету імені Івана Пулюя Міністерства освіти і науки України. Захист відбудеться «24» червня 2021 р. о 9.00 год. на засіданні екзаменаційної комісії №21 у Тернопільському національному технічному університеті імені Івана Пулюя.<br>Дана кваліфікаційній робота складається з таких розділів: – вступу, де проводиться опис актуальності автоматизації лабораторного стенду для вимірювання рівня води за допомогою р
APA, Harvard, Vancouver, ISO, and other styles
4

Abelin, Sarah. "Investigation of integrated waterlevel sensor solution forsubmersible pumps : A study of how sensors can be combined towithstand build-up materials and improvereliability in harsh environment." Thesis, KTH, Maskinkonstruktion (Inst.), 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-210223.

Full text
Abstract:
Monitoring water level in harsh environment in order to handle the start and stop function of drainage pumps has been a major issue. Several environmental factors are present, which affect and disturb sensor measurements. Current solutions with mechanical float switches, mounted outside of pumps, wear out, get entangled and account for more than half of all the emergency call outs to pumping stations. Since pumps are frequently moved around, a new sensor solution is needed which can be integrated within the pump house and is able to continuously monitor water level to optimize the operation of
APA, Harvard, Vancouver, ISO, and other styles
5

Janík, Vladimír. "Chytré čerpadlo na čerpání vody z nádrže." Master's thesis, Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií, 2021. http://www.nusl.cz/ntk/nusl-442364.

Full text
Abstract:
This thesis deals with the implementation of a system for measuring the amount of water in the tank using a 12V water pump. The whole system is controlled by the ESP32 microcontroller. The introduction deals with the theoretical analysis of various principles of measuring the level of liquids. The next part deals with the procedure of the construction of the measuring device and its theoretical analysis. The last part of the work deals with the control of the pump and the individual functions that provide this control. The ultrasonic distance sensor AJ-SR04M was chosen for the implementation o
APA, Harvard, Vancouver, ISO, and other styles
6

Fernandes, Lenita da Silva Lucio. "Controle feedback de n?vel baseado em sensor de imagem aplicado ao equipamento misturador-decantador ? invers?o de fases (MDIF?)." Universidade Federal do Rio Grande do Norte, 2009. http://repositorio.ufrn.br:8080/jspui/handle/123456789/15779.

Full text
Abstract:
Made available in DSpace on 2014-12-17T15:01:20Z (GMT). No. of bitstreams: 1 LenitaSLF.pdf: 2627101 bytes, checksum: 55e09659bccdbe036d1c49a7fea4b6ca (MD5) Previous issue date: 2009-09-03<br>Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico<br>The treatment of wastewaters contaminated with oil is of great practical interest and it is fundamental in environmental issues. A relevant process, which has been studied on continuous treatment of contaminated water with oil, is the equipment denominated MDIF? (a mixer-settler based on phase inversion). An important variable during the op
APA, Harvard, Vancouver, ISO, and other styles
7

Fraher, Patrick M. A. "Environmental sensor validation." Thesis, University of Oxford, 1995. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.308651.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Tekle, Tesfalem Tsegay. "Ultrasonic stream bridge sensors (USBS) error in water level estimation." Thesis, University of Iowa, 2014. https://ir.uiowa.edu/etd/4770.

Full text
Abstract:
After the flood event in 2008, Iowa Flood Center (IFC) designed a new water level measuring system, Ultrasonic Stream Bridge Sensors (USBS), to monitor stream water level in Iowa. The system is composed of an ultrasonic, a GSM cell modem, solar panel, and battery, and an internal temperature sensor; all components assembled in a weather proof box. The USBS are designed to be mounted in a bridge crossing and uses speed of sound to sense the distance from the sensor to the water surface. USBS are inexpensive compared to other system of water level measuring systems. However, ultrasonic sensor in
APA, Harvard, Vancouver, ISO, and other styles
9

Torunbalci, Mert Mustafa. "Wafer Level Vacuum Packaging Of Mems Sensors And Resonators." Master's thesis, METU, 2011. http://etd.lib.metu.edu.tr/upload/12613015/index.pdf.

Full text
Abstract:
This thesis presents the development of wafer level vacuum packaging processes using Au-Si eutectic and glass frit bonding contributing to the improvement of packaging concepts for a variety of MEMS devices. In the first phase of this research, micromachined resonators and pirani vacuum gauges are designed for the evaluation of the vacuum package performance. These designs are verified using MATLAB and Coventorware finite element modeling tool. Designed resonators and pirani vacuum gauges and previously developed gyroscopes with lateral feedthroughs are fabricated with a newly developed Silico
APA, Harvard, Vancouver, ISO, and other styles
10

Gatty, Hithesh K. "MEMS-based electrochemical gas sensors and wafer-level methods." Doctoral thesis, KTH, Mikro- och nanosystemteknik, 2015. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-172955.

Full text
Abstract:
This thesis describes novel microel ectromechanical system (MEMS) based electrochemical gas sensors and methods of fabrication. This thesis presents the research in two parts. In the first part, a method to handle a thin silicon wafer using an electrochemically active adhesive is described. Handling of a thin silicon wafer is an important issue in 3D-IC manufacturing where through silicon vias (TSVs) is an enabling technology. Thin silicon wafers are flexible and fragile, therefore difficult to handle. In addressing the need for a reliable solution, a method based on an electrochemically activ
APA, Harvard, Vancouver, ISO, and other styles
More sources

Books on the topic "Water Level Sensor"

1

Geological Survey (U.S.), ed. New pressure-based water-level sensor used by the U.S. Geological Survey. U.S. Geological Survey, 1992.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
2

Geological Survey (U.S.), ed. New pressure-based water-level sensor used by the U.S. Geological Survey. U.S. Geological Survey, 1992.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
3

Ksenofontov, Boris. Technologies and equipment for the creation of environmentally friendly and waste-free biotechnological industries. INFRA-M Academic Publishing LLC., 2023. http://dx.doi.org/10.12737/2048107.

Full text
Abstract:
The monograph examines modern biotechnological technologies and new equipment for solving environmental problems. The theoretical foundations of the cultivation of microorganisms and the most common ecobiotechnological technologies, including biological water purification, biotechnology of soil and air purification, as well as aerobic and anaerobic treatment of sewage sludge and waste generated during the processing of plant raw materials, are described. Possible ways of obtaining electricity by anaerobic digestion of sewage sludge are analyzed.&#x0D; It is intended for specialists in the fiel
APA, Harvard, Vancouver, ISO, and other styles
4

New pressure-based water-level sensor used by the U.S. Geological Survey. U.S. Geological Survey, 1992.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

New pressure-based water-level sensor used by the U.S. Geological Survey. U.S. Geological Survey, 1992.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
6

New pressure-based water-level sensor used by the U.S. Geological Survey. U.S. Geological Survey, 1992.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
7

Kajitvichyanukul, Puangrat, and Brian D'Arcy, eds. Land Use and Water Quality: The Impacts of Diffuse Pollution. IWA Publishing, 2022. http://dx.doi.org/10.2166/9781789061123.

Full text
Abstract:
Abstract The influence of landscapes – topography, soil, vegetation, geology – on water quality is an inherent part of the global water cycle. Land use has adverse impacts for example when soils are exposed, significant quantities of pollutants are released (including anthropogenic materials added to those naturally present), or pollutants are added directly to the water environment. Those impacts range from industrial development to farming and urbanisation. Whilst inefficient polluting industrial effluents are still tolerated in some countries, and poorly treated sewage globally remains a hu
APA, Harvard, Vancouver, ISO, and other styles
8

Crum, Brian A., Eduardo E. Benarroch, and Robert D. Brown. Neurologic Disorders Categorized by Anatomical Involvement. Oxford University Press, 2012. http://dx.doi.org/10.1093/med/9780199755691.003.0523.

Full text
Abstract:
Neurological disorders of the brain, spine, and peripheral nervous system are examined. Symptoms and signs related to disorders of the cerebral cortex may lead to alterations in cognition and consciousness. Unilateral neurologic symptoms involving a single neurologic symptom commonly localize to the cerebral cortex. Abnormalities of speech and language are localized to the dominant cerebral hemisphere, whereas abnormalities of the nondominant hemisphere may lead to visuospatial deficits, confusion, or neglect of the contralateral side of the body. The hypothalamus is important in many function
APA, Harvard, Vancouver, ISO, and other styles

Book chapters on the topic "Water Level Sensor"

1

Kłoda, Rafał, Jan Piwiński, Roman Szewczyk, Anna Ostaszewska-Liżewska, and Kamil Duchna. "Visualization River Water Level Using Internet Technologies." In Recent Trends in Control and Sensor Systems in Emergency Management. Springer International Publishing, 2017. http://dx.doi.org/10.1007/978-3-319-70452-4_2.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Xu, Changbao, Xiaobo Pu, Jiahao Fang, Tingting Yang, and Mingyong Xin. "Water Level Monitoring Sensor Based on Iontronic Piezo-Capacitance Effect." In Sustainable Development of Water and Environment. Springer Nature Switzerland, 2023. http://dx.doi.org/10.1007/978-3-031-42588-2_23.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Yesmin, Sebina, Dipankar Chetia, Tenison Basumatary, and Hidam Kumarjit Singh. "Fiber Optic Sensor for Detection of Chlorine Level in Water." In Advances in Communication, Devices and Networking. Springer Singapore, 2018. http://dx.doi.org/10.1007/978-981-10-7901-6_47.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Kumar, Suraj, Saurabh Kumar Singh, and Ashwani Kumar Tiwari. "Groundwater Level Behaviour Assessment Using Sensor-Based Water Level Recorder and GIS in Umaria Coalfield, Madhya Pradesh, India." In Mining Impact on Soil and Water Resources. CRC Press, 2025. https://doi.org/10.1201/9781003442554-14.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Majumder, Ritam, Hrishav Karmakar, Soumik Kumar Dey, Abhirup Bhattacharyya, and Subhankar Bhattacharjee. "High Precision Water Level Sensor Design and Development for Wireless Sensor Network in Agricultural IoT (AIoT)." In Springer Proceedings in Information and Communication Technologies. Springer Nature Singapore, 2024. https://doi.org/10.1007/978-981-97-5157-0_57.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Sulistyowati, Riny, Hari Agus Sujono, and Ahmad Khamdi Musthofa. "A River Water Level Monitoring System Using Android-Based Wireless Sensor Networks for a Flood Early Warning System." In Proceedings of Second International Conference on Electrical Systems, Technology and Information 2015 (ICESTI 2015). Springer Singapore, 2016. http://dx.doi.org/10.1007/978-981-287-988-2_43.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Krah, T., N. Ferreira, S. Büttgenbach, A. Wedmann, F. Härtig, and K. Kniel. "Coordinate Measurement on Wafer Level – From Single Sensors to Sensor Arrays." In Smart Sensors, Measurement and Instrumentation. Springer International Publishing, 2015. http://dx.doi.org/10.1007/978-3-319-10948-0_19.

Full text
APA, Harvard, Vancouver, ISO, and other styles
8

Xu, Jikai, Zhihao Ren, Bowei Dong, Chenxi Wang, Yanhong Tian, and Chengkuo Lee. "Evolution of Wafer Bonding Technology and Applications from Wafer-Level Packaging to Micro/Nanofluidics-Enhanced Sensing." In Advanced MEMS/NEMS Fabrication and Sensors. Springer International Publishing, 2021. http://dx.doi.org/10.1007/978-3-030-79749-2_7.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Di Mauro, A., G. F. Santonastaso, S. Venticinque, and A. Di Nardo. "Open Datasets and IoT Sensors for Residential Water Demand Monitoring at the End-Use Level: A Pilot Study Site in Naples (Italy)." In Springer Water. Springer International Publishing, 2022. http://dx.doi.org/10.1007/978-3-030-95844-2_4.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Selvaraj, S., Vijaykumar S. Nayanegali, G. Sathyavathi, and Meduri Ravi. "A Capacitive Pressure Sensor with a New Wafer Level Sealing Approach." In Lecture Notes in Mechanical Engineering. Springer Nature Singapore, 2025. https://doi.org/10.1007/978-981-96-3445-3_35.

Full text
APA, Harvard, Vancouver, ISO, and other styles

Conference papers on the topic "Water Level Sensor"

1

Sharma, Shivani, Tasin Nusrat, Mehmet Yazgan, and Stavros Vakalis. "Millimeter-wave stepped frequency radar for high-accuracy water-level monitoring." In Radar Sensor Technology XXIX, edited by Abigail S. Hedden and Gregory J. Mazzaro. SPIE, 2025. https://doi.org/10.1117/12.3053647.

Full text
APA, Harvard, Vancouver, ISO, and other styles
2

Latham, Jacob, Grace Dadzie, Alfred Kalyanapu, and Susmit Shannigrahi. "AquaCam: An ML-Enhanced Low-Cost, Deploy-Anywhere Water Level Detection Sensor." In 2025 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops). IEEE, 2025. https://doi.org/10.1109/percomworkshops65533.2025.00149.

Full text
APA, Harvard, Vancouver, ISO, and other styles
3

Frontera-Bergas, M., F. Mestre-Sansó, R. Sanchez, E. Isern, and B. Alorda-Ladaria. "Low-Cost Water Level Sensor with Improved Data Quality for Flash Flood Monitoring in Urban Areas." In 2024 IEEE SENSORS. IEEE, 2024. https://doi.org/10.1109/sensors60989.2024.10784687.

Full text
APA, Harvard, Vancouver, ISO, and other styles
4

Enriko, I. Ketut Agung, Fikri Nizar Gustiyana, FA Brian Ganda Pratama, Ahmad Luthfi, Sri Kuntadi, and Nila Indah Febriyanti. "Implementation of Ultrasonic Sensor Using LoRaWAN Protocol for Monitoring Water Level in Aquaponic Pond." In 2024 10th International Conference on Wireless and Telematics (ICWT). IEEE, 2024. http://dx.doi.org/10.1109/icwt62080.2024.10674669.

Full text
APA, Harvard, Vancouver, ISO, and other styles
5

Ranjan, Prem, and Atanu Chowdhury. "Design and Development of an Inter-digital Capacitive Sensor-based Water-level Monitoring System." In 2024 4th International Conference on Advancement in Electronics & Communication Engineering (AECE). IEEE, 2024. https://doi.org/10.1109/aece62803.2024.10911333.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Kabir, Md Shahriar, Khalid Mahmud Niloy, Md Imon Hossen, Sumaiya Afrose, and Md Ismail Hossain Mofazzol. "Development of IoT-based Scale Sensor to Measure AWD System Water Level in Crop Field." In 2024 IEEE 3rd International Conference on Robotics, Automation, Artificial-Intelligence and Internet-of-Things (RAAICON). IEEE, 2024. https://doi.org/10.1109/raaicon64172.2024.10928536.

Full text
APA, Harvard, Vancouver, ISO, and other styles
7

Dorsey, Michael H., George J. Licina, Brian J. Saldanha, and Richard C. Ebersole. "Monitoring for Corrosion and Microbiological Activity in a Cooling Water System." In CORROSION 2002. NACE International, 2002. https://doi.org/10.5006/c2002-02009.

Full text
Abstract:
Abstract Corrosion of heat exchanger tubes and carbon steel piping at a chemical processing plant had been attributed to a high level of microbiological activity in the cooling water. Two electrochemical biofilm activity sensors with integrated data acquisition and data analysis capabilities were installed in the plant’s cooling system to augment the coupon-based corrosion monitoring activity. Those sensors provided the plant with an on-line measurement and early detection of biofilm activity on metallic surfaces. Sensor response was correlated with coupon examinations, determinations of bioci
APA, Harvard, Vancouver, ISO, and other styles
8

Hartono, Ambran, Salsabila Tahta Hirani Putri, Naufal Dzaki, Biaunik Niski Kumila, Edi Sanjaya, and Nashrul Hakiem. "Developing Sensor of a Water Level Control Prototype Using Fuzzy Logic Based on Soil Moisture Levels with Internet of Things Integration." In 2024 12th International Conference on Cyber and IT Service Management (CITSM). IEEE, 2024. https://doi.org/10.1109/citsm64103.2024.10775887.

Full text
APA, Harvard, Vancouver, ISO, and other styles
9

Iseri, Hajime, and Takahiko Uchida. "Prevention of MIC in Cooling Water Systems by Using a New Monitoring & Control System." In CORROSION 2002. NACE International, 2002. https://doi.org/10.5006/c2002-02006.

Full text
Abstract:
Abstract The potential ennoblement of corrosion resistant metals, such as stainless steel, is thought to be one of the processes of microbiologically influenced corrosion (MIC).1)-3) In order to prevent MIC, the electrical potential of metals must keep under a critical level. Electrical potential monitoring and control is necessary to prevent MIC in a cooling water environment. A new type of monitoring and control system has been developed in this study. The concept of this system is to detect hazardous MIC at low levels, and to control the microorganisms proactively. In order to detect the mi
APA, Harvard, Vancouver, ISO, and other styles
10

Diederichs, Annika Martina, Anders Nilas Rosborg Black, Khadijeh Nastaran Jafari, and Birit Buhr. "Integrity Evaluation of Offshore Wind Structures Utilizing Complementary Monitoring Techniques." In CONFERENCE 2023. AMPP, 2023. https://doi.org/10.5006/c2023-19292.

Full text
Abstract:
Abstract To categorize the level of corrosion internally in uncoated offshore wind turbine structures a combination of different online monitoring systems has successfully been utilized combining findings from online corrosion monitoring, continuous water level monitoring and online water quality monitoring. Online water level monitoring is being used to identify leakage of the J-Tube seal and evaluating corresponding corrosion risks as not all leakages can be identified by manual measurements, which are typically only performed over a few hours. The findings of the water level monitoring are
APA, Harvard, Vancouver, ISO, and other styles

Reports on the topic "Water Level Sensor"

1

Raymond, Kara, Laura Palacios, Cheryl McIntyre, and Evan Gwilliam. Status of climate and water resources at Chiricahua National Monument, Coronado National Memorial, and Fort Bowie National Historic Site: Water year 2019. National Park Service, 2022. http://dx.doi.org/10.36967/nrr-2293370.

Full text
Abstract:
Climate and hydrology are major drivers of ecosystems. They dramatically shape ecosystem structure and function, particularly in arid and semi-arid ecosystems. Understanding changes in climate, groundwater, and water quality and quantity is central to assessing the condition of park biota and key cultural resources. The Sonoran Desert Network collects data on climate, groundwater, and surface water at 11 National Park Service units in southern Arizona and New Mexico. This report provides an integrated look at climate, groundwater, and springs conditions at Chiricahua National Monument (NM), Co
APA, Harvard, Vancouver, ISO, and other styles
2

Seginer, Ido, Louis D. Albright, and Robert W. Langhans. On-line Fault Detection and Diagnosis for Greenhouse Environmental Control. United States Department of Agriculture, 2001. http://dx.doi.org/10.32747/2001.7575271.bard.

Full text
Abstract:
Background Early detection and identification of faulty greenhouse operation is essential, if losses are to be minimized by taking immediate corrective actions. Automatic detection and identification would also free the greenhouse manager to tend to his other business. Original objectives The general objective was to develop a method, or methods, for the detection, identification and accommodation of faults in the greenhouse. More specific objectives were as follows: 1. Develop accurate systems models, which will enable the detection of small deviations from normal behavior (of sensors, contro
APA, Harvard, Vancouver, ISO, and other styles
3

Belkin, Shimshon, Sylvia Daunert, and Mona Wells. Whole-Cell Biosensor Panel for Agricultural Endocrine Disruptors. United States Department of Agriculture, 2010. http://dx.doi.org/10.32747/2010.7696542.bard.

Full text
Abstract:
Objectives: The overall objective as defined in the approved proposal was the development of a whole-cell sensor panel for the detection of endocrine disruption activities of agriculturally relevant chemicals. To achieve this goal several specific objectives were outlined: (a) The development of new genetically engineered wholecell sensor strains; (b) the combination of multiple strains into a single sensor panel to effect multiple response modes; (c) development of a computerized algorithm to analyze the panel responses; (d) laboratory testing and calibration; (e) field testing. In the course
APA, Harvard, Vancouver, ISO, and other styles
4

Greinert, Jens. Mine Monitoring in the German Baltic Sea 2020; Dumped munition monitoring AL548, 03rd – 16th November 2020, Kiel (Germany) – Kiel (Germany) „MineMoni-II 2020“. GEOMAR Helmholtz Centre for Ocean Research Kiel, 2021. http://dx.doi.org/10.3289/cr_al548.

Full text
Abstract:
ALKOR cruise AL548 took place as part of the EMFF (European Maritime and Fisheries Fund)-funded project BASTA (Boost Applied munition detection through Smart data inTegration and AI workflows; https://www.basta-munition.eu) and as continuation of the munition monitoring started within the BMBF-funded project UDEMM (Environmental Monitoring for the Delaboration of Munition in the Sea; https://udemm.geomar.de/). In October 2018, a first cruise (POS530 MineMoni2018) was conducted, to gather data for a broad baseline study in the German Baltic Sea. Results show a moderate contamination level on re
APA, Harvard, Vancouver, ISO, and other styles
5

Raymond, Kara, Laura Palacios, Cheryl McIntyre, and Evan Gwilliam. Status of climate and water resources at Saguaro National Park: Water year 2019. Edited by Alice Wondrak Biel. National Park Service, 2021. http://dx.doi.org/10.36967/nrr-2288717.

Full text
Abstract:
Climate and hydrology are major drivers of ecosystems. They dramatically shape ecosystem structure and function, particularly in arid and semi-arid ecosystems. Understanding changes in climate, groundwater, and water quality and quantity is central to assessing the condition of park biota and key cultural resources. The Sonoran Desert Network collects data on climate, groundwater, and surface water at 11 National Park Service units in south-ern Arizona and New Mexico. This report provides an integrated look at climate, groundwater, and springs conditions at Saguaro National Park (NP) during wa
APA, Harvard, Vancouver, ISO, and other styles
6

Sridhar, Yang, and Song. 4VRVLN6 Effects of Solids and Biofilms on Dewpoint and Corrosion in Pipelines. Pipeline Research Council International, Inc. (PRCI), 2008. http://dx.doi.org/10.55274/r0011265.

Full text
Abstract:
Internal corrosion occurs where water or other corrosive electrolyte accumulates. This is the principle used in Internal Corrosion Direct Assessment (ICDA). Although ICDA focuses on nominally dry gas with episodes of water upset, the well accepted criteria for dry gas (e.g., water less than 7 lb/MMCF) may be significantly influenced by the presence of bacterial biofilms and hygroscopic solids, such as iron oxide corrosion products and some salts. Therefore, understanding the changes in dew point induced by the presence of these compounds is necessary to better quantify gas quality requirements
APA, Harvard, Vancouver, ISO, and other styles
7

Marshall, Amber, Krystle Turner, Carol Richards, Marcus Foth, Michael Dezuanni, and Tim Neale. A case study of human factors of digital AgTech adoption: Condamine Plains, Darling Downs. Queensland University of Technology, 2021. http://dx.doi.org/10.5204/rep.eprints.227177.

Full text
Abstract:
As global agricultural production methods and supply chains have become more digitised, farmers around the world are adopting digital AgTech such as drones, Internet of Things (IoT), remote sensors, blockchain, and satellite imagery to inform their on-farm decision-making. While early adopters and technology advocates globally are spruiking and realising the benefits of digital AgTech, many Australian farmers are reluctant or unable to participate fully in the digital economy. This is an important issue, as the Australian Government has said that digital farming is essential to meeting its tar
APA, Harvard, Vancouver, ISO, and other styles
8

Friedman, Shmuel, Jon Wraith, and Dani Or. Geometrical Considerations and Interfacial Processes Affecting Electromagnetic Measurement of Soil Water Content by TDR and Remote Sensing Methods. United States Department of Agriculture, 2002. http://dx.doi.org/10.32747/2002.7580679.bard.

Full text
Abstract:
Time Domain Reflectometry (TDR) and other in-situ and remote sensing dielectric methods for determining the soil water content had become standard in both research and practice in the last two decades. Limitations of existing dielectric methods in some soils, and introduction of new agricultural measurement devices or approaches based on soil dielectric properties mandate improved understanding of the relationship between the measured effective permittivity (dielectric constant) and the soil water content. Mounting evidence indicates that consideration must be given not only to the volume frac
APA, Harvard, Vancouver, ISO, and other styles
9

Hodul, M., H. P. White, and A. Knudby. A report on water quality monitoring in Quesnel Lake, British Columbia, subsequent to the Mount Polley tailings dam spill, using optical satellite imagery. Natural Resources Canada/CMSS/Information Management, 2022. http://dx.doi.org/10.4095/330556.

Full text
Abstract:
In the early morning on the 4th of August 2014, a tailings dam near Quesnel, BC burst, spilling approximately 25 million m3 of runoff containing heavy metal elements into nearby Quesnel Lake (Byrne et al. 2018). The runoff slurry, which included lead, arsenic, selenium, and vanadium spilled through Hazeltine Creek, scouring its banks and picking up till and forest cover on the way, and ultimately ended up in Quesnel Lake, whose water level rose by 1.5 m as a result. While the introduction of heavy metals into Quesnel Lake was of environmental concern, the additional till and forest cover scour
APA, Harvard, Vancouver, ISO, and other styles
10

Chea, Chou. The Local Governance of Common Pool Resources: The Case of Irrigation Water in Cambodia. Cambodia Development Resource Institute, 2010. https://doi.org/10.64202/wp.47.201008.

Full text
Abstract:
The study seeks out the factors that enable or constrain the good governance of common pool resources in Cambodia, using irrigation water as the case for analysis. It explores the dynamics of community-based natural resource management (CBNRM) and decentralised natural resource management (DNRM) from a local perspective and how these two approaches interact. The study found that CBNRM, an approach that is being implemented locally to manage irrigation water, is working, although unsatisfactorily due to three main constraints. The first is difficulty maintaining the participation of the communi
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!