To see the other types of publications on this topic, follow the link: Type implant.

Dissertations / Theses on the topic 'Type implant'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 dissertations / theses for your research on the topic 'Type implant.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse dissertations / theses on a wide variety of disciplines and organise your bibliography correctly.

1

ROGERS, RICHARD RALPH JR. "INDIVIDUAL ADJUSTMENT, COUPLE CORRESPONDENCE ON ADJUSTMENT AND TYPE OF PENILE IMPLANT RECEIVED AS CORRELATES OF SEXUAL AND IMPLANT SATISFACTION (IMPOTENCE, ERECTILE, DYSFUNCTION)." Diss., The University of Arizona, 1986. http://hdl.handle.net/10150/183783.

Full text
Abstract:
This study was an ex post facto analysis of data gathered on 49 couples in which the men were organically impotent and subsequently received either an inflatable (n = 34), noninflatable penile prosthesis (n = 11) or both, in succession (n = 4). One purpose of this study was to examine the degree of correspondence for the patient and partner on their postsurgical psychological and sexual adjustment. The second purpose was to assess the relative contribution of each individual's psychological and sexual adjustment, couple correspondence on their adjustment, and the type of implant received on th
APA, Harvard, Vancouver, ISO, and other styles
2

Pessoa, Roberto Sales e. [UNESP]. "Influência do tipo de conexão protética, do platform-switching e do designe do implante no ambiente biomecânico de implantes imediatos com carga imediata." Universidade Estadual Paulista (UNESP), 2010. http://hdl.handle.net/11449/104182.

Full text
Abstract:
Made available in DSpace on 2014-06-11T19:32:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-25Bitstream added on 2014-06-13T19:43:55Z : No. of bitstreams: 1 pessoa_rs_dr_arafo.pdf: 1780565 bytes, checksum: 78498002897f7571851e27403dd44a72 (MD5)<br>Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)<br>O objetivo do presente trabalho de pesquisa foi avaliar a influencia do tipo de conexao protetica, do platform-switching, e do design do implante no ambiente biomec.nico de implantes imediatos com carga imediata. Para tanto, um modelo de alveolo de extraçao de u
APA, Harvard, Vancouver, ISO, and other styles
3

Pessoa, Roberto Sales e. "Influência do tipo de conexão protética, do platform-switching e do designe do implante no ambiente biomecânico de implantes imediatos com carga imediata /." Araraquara : [s.n.], 2010. http://hdl.handle.net/11449/104182.

Full text
Abstract:
Resumo: O objetivo do presente trabalho de pesquisa foi avaliar a influencia do tipo de conexao protetica, do platform-switching, e do design do implante no ambiente biomec.nico de implantes imediatos com carga imediata. Para tanto, um modelo de alveolo de extraçao de um incisivo central superior foi constru.do baseado em tomografia computadorizada. Implantes inseridos no alveolo de extra..o foram avaliados por meio de analises em elementos finitos. Uma Analise de Variancia (α=0.05) foi utilizada para interpretar os dados do pico de deformaçao equivalente no osso, do pico de tens.es equivalent
APA, Harvard, Vancouver, ISO, and other styles
4

Moulton, Ethan David. "Influence of drill guide type and operator experience on accuracy of dental implant placement." Oklahoma City : [s.n.], 2006.

Find full text
APA, Harvard, Vancouver, ISO, and other styles
5

Schuler, Martin. "Multifunctional titanium dental implant surface based on biochemically modified molecular assembly systems /." Zürich : ETH, 2006. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=16914.

Full text
APA, Harvard, Vancouver, ISO, and other styles
6

Bédué, Olivier. "Synthese d'un implant refractif epicorneen a base de collagene de type quatre placentaire natif, reticule au glutaraldehyde." Paris 6, 1994. http://www.theses.fr/1994PA066724.

Full text
Abstract:
Le but de cette these est l'elaboration d'un implant refractif epicorneen a partir d'une proteine extraite du placenta humain: le collagene de type quatre, et de l'agent reticulant associe: le glutaraldehyde (pentanedial). Le premier chapitre de ce memoire est consacre a une etude bibliographique complete de la chimie et de la biochimie du collagene, du glutaraldehyde et de leurs interactions. Dans un deuxieme chapitre, nous presentons l'elaboration de la mise en uvre des materiaux collageniques par la methode de moulage en rotation, et l'etude des conditions d'hydratation et de reticulation d
APA, Harvard, Vancouver, ISO, and other styles
7

Bittencourt, Rodolfo Sommer. "Efeito do tipo e do posicionamento de reforço estrutural de sobredentaduras implanto-suportadas na transmissão de cargas aos implantes = Effect of the type and design of structural reinforcements of implant-supported overdentures in the stress transmission onto implants / Rodolfo Sommer Bittencourt ; orientador, Rodrigo Nunes Rached." reponame:Biblioteca Digital de Teses e Dissertações da PUC_PR, 2009. http://www.biblioteca.pucpr.br/tede/tde_busca/arquivo.php?codArquivo=1690.

Full text
Abstract:
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2009<br>Inclui bibliografias<br>Este estudo avaliou o efeito de reforços estruturais de fibra de vidro e de metal fundido, bem como diferentes desenhos de posicionamento da fibra de vidro, no padrão de transmissão de cargas aos implantes em um modelo de sobre dentadura implanto-suportad<br>This study evaluated the effect of glass fibers and cast metal reinforcements, and different designs of the glass fibers reinforcement, in the patterns of force transmission onto the implants in an implant-supported overdenture mo
APA, Harvard, Vancouver, ISO, and other styles
8

Lundin, Karin. "Experiences from Cochlear Implantation and Auditory Brainstem Implantation in Adults and Children : Electrophysiological Measurements, Hearing Outcomes and Patient Satisfaction." Doctoral thesis, Uppsala universitet, Institutionen för kirurgiska vetenskaper, 2016. http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-275091.

Full text
Abstract:
Cochlear implants (CIs) and auditory brainstem implants (ABIs) are prostheses for hearing used in patients with profound hearing impairment. A CI requires an operational cochlear nerve to function in contrast to an ABI. ABIs were initially designed for adult patients with neurofibromatosis type 2 (NF2), suffering from bilateral vestibular schwannomas. Now ABIs are also used for patients, both adults and children, with congenital cochlear malformations, cochlear nerve hypoplasia/aplasia, and cochlear ossification. The aims of this thesis are to evaluate hearing outcome in patients implanted wit
APA, Harvard, Vancouver, ISO, and other styles
9

Frei, Christian. "The thread injection : thread transport in circular pipe flow applied in a minimally invasive openporous implant system for endonasal surgery /." [S.l.] : [s.n.], 2000. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=13549.

Full text
APA, Harvard, Vancouver, ISO, and other styles
10

Погорєлов, Максим Володимирович, Максим Владимирович Погорелов, Maksym Volodymyrovych Pohorielov та В. О. Бойко. "Особливості застосування хітозан-апатитного імплантата в ділянках кістки з різною щільністю". Thesis, Видавництво СумДУ, 2011. http://essuir.sumdu.edu.ua/handle/123456789/14107.

Full text
APA, Harvard, Vancouver, ISO, and other styles
11

Defossez, Henri Jean-Paul. "Analysis of bone remodelling around a new type of hip implant using image processing techniques applied on X-ray and DEXA systems." Thesis, University of Leeds, 2004. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.401086.

Full text
APA, Harvard, Vancouver, ISO, and other styles
12

Verma, Rohit. "Infrared neural stimulation of the cochlear nucleus : towards a new generation of auditory brainstem implants." Thesis, University of Manchester, 2014. https://www.research.manchester.ac.uk/portal/en/theses/infrared-neural-stimulation-of-the-cochlear-nucleus-towards-a-new-generation-of-auditory-brainstem-implants(acfb2108-59a4-43d9-82db-f4e68ef7edc6).html.

Full text
Abstract:
In an effort to improve the auditory brainstem implant, a prosthesis in which user outcomesare modest, infrared neural stimulation (INS) was applied to the cochlear nucleus in a ratanimal model. Pulsed INS, delivered to the surface of the cochlear nucleus via an opticalfibre, evoked auditory brainstem responses (ABR) and generated broad neural activation inthe inferior Colliculus (IC). Varying the parameters of the laser stimulation revealed laserpeak power to be the dominating parameter for both ABR and IC responses. Strongestresponses were recorded when the fibre was placed at lateral positi
APA, Harvard, Vancouver, ISO, and other styles
13

Pugliano, Marion. "Conception et optimisation d'un implant thérapeutique combiné à des organoïdes de cellules souches pour la nanomédecine régénérative ostéoarticulaire." Thesis, Strasbourg, 2019. http://www.theses.fr/2019STRAJ111.

Full text
Abstract:
Notre équipe a mis au point une stratégie innovante d’implants thérapeutiques biphasiques, pour une régénération plus efficace et plus durable du cartilage articulaire, dans le cadre du traitement des lésions ostéochondrales. Ces implants pourraient représenter de meilleures alternatives aux traitements actuellement utilisés en chirurgie orthopédique. Dans un premier temps, nous avons élaboré un modèle d’implant thérapeutique à base de collagène de type II dérivé de méduse, fonctionnalisé par des nanoréservoirs de facteurs de croissance TGF-β3 et équipé de cellules souches mésenchymateuses hum
APA, Harvard, Vancouver, ISO, and other styles
14

Mahmoud, Hussein. "A description of dental implants placed at Tygerberg Oral Health Centre." University of the Western Cape, 2019. http://hdl.handle.net/11394/7532.

Full text
Abstract:
Magister Scientiae Dentium - MSc(Dent)<br>Purpose This study analyzed the dental surgical implant therapy in the past 5 years at Tygerberg Oral Health Centre, UWC Dental School, Cape Town, South Africa. The findings of this study serve as a guideline for the estimation of the prevalence in this dental hospital. The importance of this study was to aid in the establishment of the formalized electronic database for dental implant therapy. The data generated will form a foundational basis for future studies that may be conducted in the field of implantology. Methodology A retrospective cross-se
APA, Harvard, Vancouver, ISO, and other styles
15

Mahmoud, Hussein. "A description of dental implants placed at Tygerberg Oral Health Centre." University of Western Cape, 2020. http://hdl.handle.net/11394/7242.

Full text
Abstract:
Magister Scientiae Dentium - MSc(Dent)<br>This study analyzed the dental surgical implant therapy in the past 5 years at Tygerberg Oral Health Centre, UWC Dental School, Cape Town, South Africa. The findings of this study serve as a guideline for the estimation of the prevalence in this dental hospital. The importance of this study was to aid in the establishment of the formalized electronic database for dental implant therapy. The data generated will form a foundational basis for future studies that may be conducted in the field of implantology.
APA, Harvard, Vancouver, ISO, and other styles
16

Silva, Camila Perfeito Evangelista da. "Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns." Universidade de São Paulo, 2018. http://www.teses.usp.br/teses/disponiveis/25/25146/tde-31082018-144600/.

Full text
Abstract:
Aim: To evaluate the effect of different Ti-base abutment heights and cement type on the pullout retention of zirconia-based restorations. Methods: Identical crowns were designed in a CAD software to fit two different Tibase abutment heights, as follows (n=10/group): (i) 4-mm-height Ti-base abutment (Tall), and (ii) 2.5-mm-height Ti-base abutment (Short). Four cement types were selected: (i) Temporary cement (Provisional); (ii) Glass-ionomer cement (Meron); (iii) self-adhesive resin cement (U200), and (iv) conventional resin cement (Ultimate) with universal adhesive for treatment of titanium a
APA, Harvard, Vancouver, ISO, and other styles
17

Welander, Maria. "Soft tissue integration to dental implants /." Göteborg : Deptartment of Periodontology, Institute of Odontology, The Sahlgrenska Academy at University of Gothenburg, 2008. http://hdl.handle.net/2077/18196.

Full text
APA, Harvard, Vancouver, ISO, and other styles
18

Whitehead, N. J. "The electrical assessment of oxygen implants into n-type gallium arsenide." Thesis, University of Surrey, 1990. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.236869.

Full text
APA, Harvard, Vancouver, ISO, and other styles
19

Alnasser, Anwar Salman M. "Five year survival and complication rates of dental implants in Type II diabetes patients: a systematic review." Thesis, The University of Hong Kong (Pokfulam, Hong Kong), 2011. http://hub.hku.hk/bib/B46600012.

Full text
APA, Harvard, Vancouver, ISO, and other styles
20

Hoffman, Amber L. "Types of stress placed on parents of deaf children when deciding on cochlear implantation." Online version, 2002. http://www.uwstout.edu/lib/thesis/2002/2002hoffmana.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
21

Wolf-Brandstetter, Cornelia. "Adsorptive Immobilisierung von Kollagen Typ I an Titanoxidoberflächen." Doctoral thesis, Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden, 2004. http://nbn-resolving.de/urn:nbn:de:swb:14-1095846029781-47918.

Full text
Abstract:
Titanium and titanium alloys are frequently used for implants in bone contact. In some cases (diabetis, osteoporosis) there are requirements for improved osseointegration. Initial reactions after surgery show an important influence on the long time stability of the implants. Newer studies focus on the surface composition of the implants in particular the modification with biological components. Collagen is the main component of bone and is therefore an interesting substance for the base modification of titanium implants. The aim of the work was to investigate the adsorptive immobilisation of c
APA, Harvard, Vancouver, ISO, and other styles
22

Ning, Steven. "Simulation and process development for ion-implanted N-type silicon solar cells." Thesis, Georgia Institute of Technology, 2013. http://hdl.handle.net/1853/47684.

Full text
Abstract:
As the efficiency potential for the industrial P-type Al-BSF silicon solar cell reaches its limit, new solar cell technologies are required to continue the pursuit of higher efficiency solar power at lower cost. It has been demonstrated in literature that among possible alternative solar cell structures, cells featuring a local BSF (LBSF) have demonstrated some of the highest efficiencies seen to date. Implementation of this technology in industry, however, has been limited due to the cost involved in implementing the photolithography procedures required. Recent advances in solar cell doping t
APA, Harvard, Vancouver, ISO, and other styles
23

Mathay, Margaux. "Virtual planning of Total Knee Arthroplasty surgery : Assessment of implant positioning of different implanting types." Thesis, KTH, Skolan för teknik och hälsa (STH), 2017. http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-209854.

Full text
Abstract:
Increased workload on our healthcare system calls for more automation, this too in the pre-operative planning of total knee arthroplasty (TKA) surgery. This should keep in mind however that success in TKA is measured through having proper limb alignment. This thesis project implemented a virtual positioning assessment software that provides an initial position based on its bone and implant inputs with their specific landmarks. Positions can be furtherly adapted and evaluated based on flexion facets, obtaining decreased pre-operative workloads. The software was validated through an analysis com
APA, Harvard, Vancouver, ISO, and other styles
24

Fluck, Daniel. "Ion-implanted KNbO₃ waveguides for blue-light second-harmonic generation /." Zürich, 1995. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=11225.

Full text
APA, Harvard, Vancouver, ISO, and other styles
25

Majkić, Aleksej. "Electro-optically tunable microring resonators in fluorine-implanted lithium niobate /." Zürich : ETH, 2009. http://e-collection.ethbib.ethz.ch/show?type=diss&nr=18179.

Full text
APA, Harvard, Vancouver, ISO, and other styles
26

Golozar, Mehdi. "Plasma electrolytic oxide coatings on low-modulus [beta]-type titanium alloys : applications to load-bearing orthopaedic implants." Thesis, University of Cambridge, 2015. https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.709079.

Full text
APA, Harvard, Vancouver, ISO, and other styles
27

Saha, Uttam Kumar. "Photoluminescence and kinetic of MOCVD grown P-type GaAs:Nd and Nd-implanted semi-insulating GaAs." Ohio University / OhioLINK, 1996. http://rave.ohiolink.edu/etdc/view?acc_num=ohiou1178044230.

Full text
APA, Harvard, Vancouver, ISO, and other styles
28

Hennessy, John 1980. "High mobility germanium MOSFETs : study of ozone surface passivation and n-type Dopant channel implants combined with ALD dielectrics." Thesis, Massachusetts Institute of Technology, 2010. http://hdl.handle.net/1721.1/58174.

Full text
Abstract:
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2010.<br>Cataloged from PDF version of thesis.<br>Includes bibliographical references (p. 107-111).<br>Germanium offers higher electron and hole mobility than silicon, making it an attractive option for future high-performance MOSFET applications. To date, Ge p-channel device behavior has shown promise, with many reports of measured hole mobilities exceeding that of Si. However, Ge n-channel devices have shown poor performance due to an asymmetric distribution of interface state densit
APA, Harvard, Vancouver, ISO, and other styles
29

Schwartz, Mark Aaron. "Molecular and Cellular Dynamics of the Healing Response Associated with Implanted Expanded Polytetrafluoroethylene." Diss., Tucson, Arizona : University of Arizona, 2005. http://etd.library.arizona.edu/etd/GetFileServlet?file=file:///data1/pdf/etd/azu%5Fetd%5F1410%5F1%5Fm.pdf&type=application/pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
30

Mascarenhas, Faye. "The Effect of Cyclic Loading on the Zirconia/Titanium Implant Abutment Interface and the Mechanism of Failure between Three Different Types of Abutments." The Ohio State University, 2015. http://rave.ohiolink.edu/etdc/view?acc_num=osu1440122618.

Full text
APA, Harvard, Vancouver, ISO, and other styles
31

Erichsen, Christine Margaret. "Effects of immunocastration on feedlot performance in bulls of different breed-types implanted with estradiol 17-ß." Thesis, National Library of Canada = Bibliothèque nationale du Canada, 1999. http://www.collectionscanada.ca/obj/s4/f2/dsk2/ftp01/MQ40044.pdf.

Full text
APA, Harvard, Vancouver, ISO, and other styles
32

Muster, Dominique. "Contribution a l'etude physique et a la mise en oeuvre de revetements pour implants chirurgicaux : utilisation de la dissociation thermique de composes du type metal-cabonyle : consolidation par implantation ionique non reactive." Université Louis Pasteur (Strasbourg) (1971-2008), 1992. http://www.theses.fr/1992STR13244.

Full text
Abstract:
Apres revue des differentes methodes d'elaboration de couches minces, nous justifions le choix de la dissociation thermique de composes du type metal-carbonyle (essentiellement ir et w), avec realisation d'un reacteur special, pour proteger la surface d'implants chirurgicaux metallique. L'etude de ces couches a ete realisee en utilisant les methodes modernes de la physique des surfaces (avec realisation d'un spectrometre auger specifique). L'adherence a ete examinee par differentes methodes (avec mise au point d'un scratch-test). Les conclusions ont ete les suivantes: structures cristallograph
APA, Harvard, Vancouver, ISO, and other styles
33

Aboud, Abdullah Ibrahim. "Contribution à l'étude du fonctionnement hydraulique et hydrologique de réseaux de drainage implantés sur deux types de sols lorrains : aspects quantitatif et qualitatif." Vandoeuvre-les-Nancy, INPL, 1990. http://www.theses.fr/1990INPL091N.

Full text
APA, Harvard, Vancouver, ISO, and other styles
34

MENCIO, FRANCESCA. "Implant-abutment interface:bacterial leakage and microgap formation in two different type of Implant connections." Doctoral thesis, 2014. http://hdl.handle.net/11573/918426.

Full text
Abstract:
Aim The aim of this study is to evaluate, both in vitro and in vivo, two different types of implant-abutment connections: screwed connection and cemented connection, analyzing the permeability of the IAI to bacterial colonization and the stability to chewing forces. Materials and Methods In this study were compared two different types of implant-abutment connections: internal hexagon screwed connection (Winsix®, BioSAF IN, Ancona, Italy ) Group 1; and internal hexagon cemented-conical connection (Bone System®, Milano, Italy) Group 2. Group 1 and Group 2 were compared on three levels: imp
APA, Harvard, Vancouver, ISO, and other styles
35

Su, Cheng-yu, and 蘇政于. "Adjacent Implant-Supported Prostheses Type in Posterior Mandibular:a Finite element analysis." Thesis, 2011. http://ndltd.ncl.edu.tw/handle/8k2r9u.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>醫學工程研究所<br>99<br>For the adjacent implant prostheses type. Most studies have advocated the theory of splinting implant prostheses, but don’t have clinical evidence. Therefore, the purpose of this study is to investigate the stress distribution of different prostheses types in implants and cortical bone. The distribution of stress can be obtained by applying the same loading to any position in clinically indicated with various coefficient of friction and interference. Then, the values of implants and cortical bone are used as a reference to make the prostheses type in clinical
APA, Harvard, Vancouver, ISO, and other styles
36

Wakjira, Yosef, and Yosef Wakjira. "SELECTION OF OPTIMUM THREAD SHAPE AND TYPE FOR DENTAL IMPLANT AND NUMERICAL ANALYSIS OF INTERFACE OF IMPLANT AND CORTICAL BONE." Thesis, 2019. http://ndltd.ncl.edu.tw/handle/7k3vwg.

Full text
Abstract:
碩士<br>國立臺灣科技大學<br>機械工程系<br>107<br>The choice of the thread structure of the implant plays a crucial role in the dental treatment. This study was undertaken to: i - Identify the optimum design of the thread, ii - Investigate the impacts of different implant thread models on bone implant-interface stress distribution, iii - Investigate Static and other behaviors of implants. On the Other hand, At the interface of the jawbone and roots of teeth, the effect of stress distribution in the interface of cortical bone and implant (PDL) is evaluated along with the numerical analysis. A full mechanical s
APA, Harvard, Vancouver, ISO, and other styles
37

WANG, YU-WEI, and 王昱崴. "Early-Voltage Variation and Dependence of VT Implant for n-type FinFETs." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/47365866755668715959.

Full text
Abstract:
碩士<br>明新科技大學<br>電子工程系碩士班<br>104<br>Planar field effect transistors in semiconductor industry have been used for a long time, playing a main role in the past. Since the process technology is promoted, the shrinkage of device profile is well done. However, this technology gradually approaches the physical limitation. Most of researchers or scientists seek the other available alternatives. A fin field effect transistor (FinFET) device seems a good choice in this process era. In this study, the FinFETs compared to the conventional planar field-effect transistors, increasing the transistor chann
APA, Harvard, Vancouver, ISO, and other styles
38

Lien, Hsu Sheng, and 連旭昇. "Fabrication of N-Type Solar Cells by Boron Ion Implant and Phosphorus Diffusion." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/76699146793072018256.

Full text
APA, Harvard, Vancouver, ISO, and other styles
39

Guedes, Sara Catarina Oliveira. "Radiological outcomes of bimalleolar fractures: are timing of surgery and type of implant important?" Master's thesis, 2020. https://hdl.handle.net/10216/128864.

Full text
Abstract:
Introdução: O objetivo da cirurgia de redução aberta e fixação interna (ORIF) das fraturas bimaleolares do tornozelo é reconstituir a anatomia do mesmo. Os parâmetros radiológicos mais comummente usados para avaliar a qualidade da redução são tibiofibular clear space (TFCS), tibiofibular overlap (TFO), talocrural angle (TCA) e medial clear space (MCS). Atualmente são escassos os estudos sobre os resultados radiológicos da cirurgia nas fraturas bimaleolares. O objetivo deste estudo é avaliar a qualidade da cirurgia assim como os fatores envolvidos na restauração anatómica, no pós-operatório e n
APA, Harvard, Vancouver, ISO, and other styles
40

Guedes, Sara Catarina Oliveira. "Radiological outcomes of bimalleolar fractures: are timing of surgery and type of implant important?" Dissertação, 2020. https://hdl.handle.net/10216/128864.

Full text
Abstract:
Introdução: O objetivo da cirurgia de redução aberta e fixação interna (ORIF) das fraturas bimaleolares do tornozelo é reconstituir a anatomia do mesmo. Os parâmetros radiológicos mais comummente usados para avaliar a qualidade da redução são tibiofibular clear space (TFCS), tibiofibular overlap (TFO), talocrural angle (TCA) e medial clear space (MCS). Atualmente são escassos os estudos sobre os resultados radiológicos da cirurgia nas fraturas bimaleolares. O objetivo deste estudo é avaliar a qualidade da cirurgia assim como os fatores envolvidos na restauração anatómica, no pós-operatório e n
APA, Harvard, Vancouver, ISO, and other styles
41

Ventura, Rita de Cássia Cabral. "Influence of connection type (internal VS. external) on implant impression accuracy: an in vitro study." Master's thesis, 2015. http://hdl.handle.net/10451/25827.

Full text
Abstract:
Tese de Mestrado, Medicina Dentária, Universidade de Lisboa, Faculdade de Medicina Dentária, 2015<br>Purpose: The aim of the present study was to evaluate if there was any significant difference in accuracy between implant-level impressions made on internal connection and external connection implant systems. The null hypothesis tested was that the accuracy of implant-impressions was not affected when internal connection or external connection implants were used. Materials and Methods: Two master models were fabricated with polyurethane by duplicating an edentulous mandibular arch. In each mode
APA, Harvard, Vancouver, ISO, and other styles
42

Chen, Chun-Ta, and 陳俊達. "A Study on Quality Control for Implant-type Scrap PC Electric Poles for Foundation Construction." Thesis, 2005. http://ndltd.ncl.edu.tw/handle/58661056492935554945.

Full text
Abstract:
碩士<br>國立成功大學<br>建築學系碩博士班<br>93<br>Reducing construction waste is one of the evaluations criteria for the national standards of green building. To properly carry out the concept of recycling and reusing waste materials requires us to reconsider the property of the materials, and their reuse value. Taiwan Power Company’s scrap PC electric poles will increase in number due to “expansion of roads”, “external vandalism” and “City Electric Wires and Cable Underground Replacement Plan”, etc. The scrap poles’ material and property are similar to the PC stake. Right now, it is common in the country
APA, Harvard, Vancouver, ISO, and other styles
43

CHEN, CHUNG-JEN, та 陳忠任. "Research of high-temperature microstructural characteristics,mechanical properties and biocompatibility on β-type titanium implant alloys". Thesis, 2014. http://ndltd.ncl.edu.tw/handle/v39z59.

Full text
Abstract:
碩士<br>臺北醫學大學<br>醫療器材產業碩士專班<br>102<br>The Ti-25Ta alloy was characterized via optical microscopy, scanning electron microscopy, X-ray diffraction, transmission electron microscopy, hardness test, contact angle test and biological assay. It was found that the volume fraction of the needle-like ?恁? martensite phase decreased with increasing the heat treatment temperature. When the alloy underwent heat treatment at temperatures between 700°C and 1000°C, its microstructure was essentially a (?? + ?恁?) phase structure. The hardness test results for the TTa-3 sample exhibits the maximum Hv value to t
APA, Harvard, Vancouver, ISO, and other styles
44

Liaw, Ying-Chu, and 廖盈筑. "Accuracy on dental implant positioning for 3D printing surgical guide with Master or C type sleeves." Thesis, 2016. http://ndltd.ncl.edu.tw/handle/23u7mv.

Full text
Abstract:
碩士<br>國立陽明大學<br>生物醫學工程學系<br>104<br>Steroligthographic surgical guide could provide accurate position in implant surgery. However, it would be restricted in surgical space of posterior region for maximum mouth opening limitation. Types of sleeves were used to solve the problem, but the accuracy between different kinds of sleeves was unknown. The aim of this study was using surgical templates with master and C type sleeves to get the deviation of implant neck, implant apex, axial angulation from actual implant placement. To compare the accuracy for types of sleeves. There were two parts in this
APA, Harvard, Vancouver, ISO, and other styles
45

Chang, Kai-Chun, and 張凱鈞. "Surface Characterizations and Cell responses of Titanium Surface Coated with Type I Collagen Using a Natural Cross-Linker for Implant Applications." Thesis, 2014. http://ndltd.ncl.edu.tw/handle/8t774h.

Full text
Abstract:
碩士<br>國立陽明大學<br>口腔生物研究所<br>102<br>Titanium (Ti) metal is widely used for biomedical applications. It owns good mechanical properties, corrosion resistance and biocompatibility. However, Ti belongs to bioinert materials, which means it can’t initiate good responses or interactions to surrounding biological tissue. Many investigators developed several surface modification methods to enhance the surface bioactivity of Ti. One of the commonly used for surface modifications is immobilization of bioactive molecules on Ti surface, which can trigger the desired tissue responses, for example: recruitin
APA, Harvard, Vancouver, ISO, and other styles
46

Tremblay, Corinne. "L'intégration audiovisuelle en fonction du type de stimuli, de la maturation, de l'intégrité neurologique et de l'expérience." Thèse, 2008. http://hdl.handle.net/1866/6708.

Full text
APA, Harvard, Vancouver, ISO, and other styles
47

Astudillo, Joel Luan de Racskai Robert. "Manufacture and viability assessment of a composite Ti/HAp coating for replacement of single HAp layers on stain-less steel type 316 medical implant spinal screws." Master's thesis, 2019. http://hdl.handle.net/10362/73718.

Full text
Abstract:
Current medical implant spinal screws rely on a thin Hydroxyapatite layer to im-prove bone-implant fixation, however this coating presents weak mechanical strength performance. Recent advances in materials science research have explored the production of composite coating for the use in medical implant coatings industry. This new field of composite engineering approaches, enabled a promising cheaper and improved alter-native to current production methods using solely Hydroxyapatite. CERAMED S.A. in-terest on developing new upgraded and cheaper Atmospheric Plasma Spray coatings culminated on t
APA, Harvard, Vancouver, ISO, and other styles
48

Jiang, Bo-Ren, and 江博仁. "Investigation of Si-implanted p-type GaN." Thesis, 2002. http://ndltd.ncl.edu.tw/handle/76147071454078862055.

Full text
Abstract:
碩士<br>國立中央大學<br>光電科學研究所<br>90<br>p-type GaN can be converted to n-type by Si + ion implantation. We used AFM, XRD, PL, Raman scattering, Hall, and DLTS measurement to investigate the mechanism of this conversion.
APA, Harvard, Vancouver, ISO, and other styles
49

Tsung, Wei-Hao, and 鐘偉豪. "Biomechanical Analysis of Implants with Different Screw-type in Mandibular Molar Area." Thesis, 2006. http://ndltd.ncl.edu.tw/handle/74425709237143398040.

Full text
Abstract:
碩士<br>高雄醫學大學<br>牙醫學研究所碩士班<br>94<br>In recent the applications of dental implants are becoming more and more prevalent. The problems related to the prosthesis of dental implants, therefore, had been noted because dental implants are more in the posterior area in which there were always loaded with high occlusion forces. The success of dental implants mainly depends on how much forces in the prosthesis can endure. Dentists and scholars had been working to obtain a high success rate of dental implants, since it was introduced. Clinical studies have been reported that the significant bone loss ar
APA, Harvard, Vancouver, ISO, and other styles
50

Yang, Jheng Wei, and 楊政偉. "Development of plunger-type 3D printer for the manufacture of biodegradable implants." Thesis, 2017. http://ndltd.ncl.edu.tw/handle/q7wjcm.

Full text
Abstract:
碩士<br>長庚大學<br>機械工程學系<br>105<br>The Fused Deposition Modeling technology is a common available method in most of the 3D printing process. The mandatory step of the high temperature process becomes a major limitation for its clinical practices, especially in the medical application. In this study, we designed and developed a new plunger-type 3D printer in order to solve the major deficit of the high temperature process in 3D printing process. This main design of this plunger 3D printer included the usage of Dichloromethane as a solvent to solve the materials of Polycaprolactone (PCL), Lidocaine,
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!