To see the other types of publications on this topic, follow the link: Type implant.

Journal articles on the topic 'Type implant'

Create a spot-on reference in APA, MLA, Chicago, Harvard, and other styles

Select a source type:

Consult the top 50 journal articles for your research on the topic 'Type implant.'

Next to every source in the list of references, there is an 'Add to bibliography' button. Press on it, and we will generate automatically the bibliographic reference to the chosen work in the citation style you need: APA, MLA, Harvard, Chicago, Vancouver, etc.

You can also download the full text of the academic publication as pdf and read online its abstract whenever available in the metadata.

Browse journal articles on a wide variety of disciplines and organise your bibliography correctly.

1

Farkhodjon Khusenovich, Mamatkulov. "MODERN APPROACHES TO THE DEVELOPMENT AND USE OF BIOCOMPATIBLE IMPLANTS: MATERIALS, TECHNOLOGIES AND PROSPECTS." Journal of Medical Genetics and Clinical Biology 2, no. 1 (2025): 148–56. https://doi.org/10.61796/jmgcb.v2i1.1207.

Full text
Abstract:
Objective: This study aims to evaluate the osseointegration potential of stainless steel implants manufactured using additive technologies for tibial prosthetics in rabbits, focusing on mechanical stability and bone-implant integration. Method: The experimental study was conducted on six chinchilla rabbits aged 6–8 months. Under general anesthesia, each rabbit underwent leg amputation followed by the implantation of a screw-type stainless steel implant produced through additive manufacturing. The implants were stabilized using the Ilizarov apparatus for six weeks. Clinical assessments, radiolo
APA, Harvard, Vancouver, ISO, and other styles
2

Tal, Haim, Vadim Reiser, Sarit Naishlos, Gal Avishai, Roni Kolerman, and Liat Chaushu. "Screw-Type Collar vs. Non-Screw-Type Collar Implants—Comparison of Initial Stability, Soft Tissue Adaptation, and Early Marginal Bone Loss—A Preclinical Study in the Dog." Biology 11, no. 8 (2022): 1213. http://dx.doi.org/10.3390/biology11081213.

Full text
Abstract:
Background: Implant neck characteristics may affect initial implant stability, soft tissue healing, and early marginal bone loss (EMBL) at second-stage surgery. The null hypothesis was that, following two-stage implant insertion, rough surface, non-screw-type collar implants will present lower EMBL at 2nd-stage surgery than rough-surface, screw-type collar implants. Methods: The study comprised seven male beagle dogs (mean weight 10.57 ± 2.8 kg; range 9–17 kg). A novel implant design was developed, composed of 2 parts: an apical part resembling a regular threaded implant, and a coronal non-scr
APA, Harvard, Vancouver, ISO, and other styles
3

Zhang, Jinyang, Xiao Zhang, Yang Chen, Wei Feng, and Xianshuai Chen. "Novel Design and Finite Element Analysis of Diamond-like Porous Implants with Low Stiffness." Materials 14, no. 22 (2021): 6918. http://dx.doi.org/10.3390/ma14226918.

Full text
Abstract:
The purpose of this study was to design porous implants with low stiffness and evaluate their biomechanical behavior. Thus, two types of porous implants were designed (Type I: a combined structure of diamond-like porous scaffold and traditional tapered thread. Type II: a cylindrical porous scaffold filled by arrayed basic diamond-like pore units). Three implant-supported prosthesis models were constructed from Type I, Type II and commercial implants (control group) and were evaluated by finite element analysis (FEA). The stress distribution pattern of the porous implants were assessed and comp
APA, Harvard, Vancouver, ISO, and other styles
4

Oates, T. W., S. Dowell, M. Robinson, and C. A. McMahan. "Glycemic Control and Implant Stabilization in Type 2 Diabetes Mellitus." Journal of Dental Research 88, no. 4 (2009): 367–71. http://dx.doi.org/10.1177/0022034509334203.

Full text
Abstract:
Diabetes mellitus is considered a relative contra-indication for implant therapy. However, the effect of glycemic level on implant integration in persons with diabetes remains poorly understood. The hypothesis of this research was that poor glycemic control is directly related to short-term-impairment implant stabilization. This prospective clinical study evaluated 10 non-diabetic individuals (12 implants) and 20 persons with type 2 diabetes (30 implants). Glycated hemoglobin (HbA1c) levels ranged from 4.7–12.6%. Implant stability was assessed by resonance frequency analysis over 4 months foll
APA, Harvard, Vancouver, ISO, and other styles
5

Velmurugan, D., T. Pridhar, T. Yuvaraj, R. Srinivasan, and B. Suresh Babu. "Studying the biomechanical effects of zirconia implant geometry and bone quality on the bone-implant interface using finite element analysis." Journal of Optoelectronic and Biomedical Materials 13, no. 2 (2021): 67–75. http://dx.doi.org/10.15251/jobm.2021.132.67.

Full text
Abstract:
The success of dental implants is influenced by several biomechanical factors such as implant design, bone quality, length of the implant, and the load transferred to the implant. The present studyaimsto determine the effects of bone quality, implant length, and bone type on stress/strain distribution in bone and implant for a zirconia implant. The study was performed using the three dimensional finite element analysis and four different lengths, two types of implants, and four different bone qualities. The Elastic modulus of a cancellous bone was varied to represent the four different bone qu
APA, Harvard, Vancouver, ISO, and other styles
6

Muhammad Ikman Ishak, Ruslizam Daud, Siti Noor Fazliah Mohd Noor, Khor Chu Yee, and Husniyati Roslan. "The Effect of Implant Length and Bone Quality on the Biomechanical Responses of Dental Implant and Surrounding Bone – A Three-Dimensional Finite Element Analysis." Journal of Advanced Research in Applied Mechanics 118, no. 1 (2024): 13–27. http://dx.doi.org/10.37934/aram.118.1.1327.

Full text
Abstract:
The robustness of dental implant systems in the context of occlusal restoration relies significantly on biomechanical factors associated with the imposition of excessive loads. These factors encompass the macro geometries of the implants, bone qualities, parafunctional oral habits, and specific materials employed. The choice of different implant lengths in different bone qualities may give rise to distinct effects on the way loads are distributed across the interface between the implant and the adjacent bone. As of now, the influence of implant length and bone quality on the surrounding tissue
APA, Harvard, Vancouver, ISO, and other styles
7

Min-Hsuan Lin, Min-Hsuan Lin, 馮已榕 Min-Hsuan Lin, 陳俊榮 I-Jung Feng, and 毛念平 Chun-Jung Chen. "Evaluation of Peri-implant Bone Change and its Risk Factors in Patients Presenting to a Medical Center: A 7-year Cross-sectional Study." Journal of Periodontics and Implant Dentistry 5, no. 2 (2022): 081–87. http://dx.doi.org/10.53106/261634032022090502001.

Full text
Abstract:
<p>Abstract: Objective: To evaluate the amount of peri-implant bone loss detected on digital panoramic radiographs in patient presenting to Chi-Mei medical center and to determine the factors associated with peri-implant bone loss. Materials and Methods: The panoramic radiographs of patient who presenting to Chi-Mei medical center (CMH) form year of 2008 to 2014 were screened. Those with at least one dental implant were selected and further evaluated. Submerged implants, implants with healing cap, failure implants, and implants with blurred vision were excluded. For patient level, sex, a
APA, Harvard, Vancouver, ISO, and other styles
8

de Carvalho Silva Leocádio, Amanda, Matusalém Silva Júnior, Guilherme José Pimentel Lopes de Oliveira, et al. "Evaluation of Implants with Different Macrostructures in Type I Bone—Pre-Clinical Study in Rabbits." Materials 13, no. 7 (2020): 1521. http://dx.doi.org/10.3390/ma13071521.

Full text
Abstract:
The objective of this study was to assess the primary stability and the osseointegration process in implants with different macrostructures (Cylindrical vs. Hybrid Conical) in rabbit tibiae. Twenty-four (24) rabbits were used, divided into 3 experimental periods (2, 4 and 8 weeks) with 8 animals each. Each animal bilaterally received 2 implants from each group in the tibial metaphysis: Cylindrical Implant (CI) and Hybrid Conical Implant (HCI). All implants were assessed for insertion torque. After the experimental periods, one of the implants in each group was submitted to the removal counter-
APA, Harvard, Vancouver, ISO, and other styles
9

Shosheva, Olesya, Mikhail Zhmaylo, Leonid Maslov, et al. "Comparative analysis of lumbar spine reconstruction using implants made of homogeneous PEEK and lattice titanium." Russian journal of biomechanics. 29, no. 1 (2025): 53–73. https://doi.org/10.15593/rjbiomech/2025.1.04.

Full text
Abstract:
Despite significant advances in neurosurgery, stable spinal reconstruction after total en bloc spondylectomy (TES) remains a challenge. This procedure standardly consists of replacing the vertebra with an implant and performing transpedicular fixation. However, standard serial implants do not always provide sufficient support and adequate load distribution, increasing the risks of instability, deformations and subsidence of the implant. It is therefore crucial to develop customized implants based on additive technologies. Three different implants were examined in this study: two polymeric impl
APA, Harvard, Vancouver, ISO, and other styles
10

Kuntjoro, Mefina, Nike Hendrijantini, Agus Dahlan, Husniya Juwita Farha, and Mayang Aziza Hanif Ardianto. "An Overview of Type 2 Diabetes Mellitus (T2DM): Dental Implant Survival Rates." Indonesian Journal of Prosthodontics 3, no. 2 (2022): 61–65. http://dx.doi.org/10.46934/ijp.v3i2.124.

Full text
Abstract:
Background: Dental implants are an alternative treatment to replace missing teeth, as it is one of the oral health problems in the elderly. The success of dental implants is affected by a process known as osseointegration. Systemic conditions such as T2DM can interfere with the osseointegration process which can lead to implant failure. As the patient's blood glucose level increases, it will increase the accumulation of AGEs. These AGEs will interfere with the stages of bone-implant contact and also bone growth around the implant Objectives: To review dental implant survival rates in T2DM pati
APA, Harvard, Vancouver, ISO, and other styles
11

Romanos, Georgios E., Rafael Arcesio Delgado-Ruiz, and Ana I. Nicolas-Silvente. "Volumetric Changes in Morse Taper Connections After Implant Placement in Dense Bone. In-Vitro Study." Materials 13, no. 10 (2020): 2306. http://dx.doi.org/10.3390/ma13102306.

Full text
Abstract:
The stability of the implant–abutment interface is crucial for the maintenance of the implant index integrity. Several factors are capable of inducing deformation in implant–abutment connection, such as the actual insertion of the implant into the bone. This study aimed to evaluate the deformations produced in the connection after the insertion of the implant. Ten implants with two different implant carriers (Type A: carrier attached to platform and Type B: carrier attached inside the index-connection) were placed in artificial Type II bone, and volumetric changes were evaluated for different
APA, Harvard, Vancouver, ISO, and other styles
12

Vermeulen, Lisa, Aladdin Speelman, Valdiela Daries, and Vincent Philips. "Development of a radiographic dental implant guide for identification of dental implant types." South African Dental Journal 75, no. 8 (2020): 432–37. http://dx.doi.org/10.17159/2519-0105/2020/v75no8a3.

Full text
Abstract:
INTRODUCTION: Identification of dental implant types can be a complex process for inexperienced health care professionals. Dental implants can have subtle differences in their morphology, which make it difficult to distinguish them from one another The unique appearance of dental anatomy and the placement of custom restorations ensure accurate identification of bodies or human remains when radiographic techniques are correctly applied. AIMS AND OBJECTIVES: To develop a radiographic dental implant guide for ten common dental implant types currently used in the Western Cape, South Africa; using
APA, Harvard, Vancouver, ISO, and other styles
13

Kim, Yang-Hee, Dong-Wook Park, Keun-Yeong Song, Hyung-Guhn Lim, Jeong-Pil Jeong, and Jae-Hong Kim. "Use of High-Resolution Ultrasound in Characterizing the Surface Topography of a Breast Implant." Medicina 59, no. 6 (2023): 1092. http://dx.doi.org/10.3390/medicina59061092.

Full text
Abstract:
Background and Objectives: With the emergence of breast implant-associated anaplastic large cell lymphoma (BIA-ALCL), it has become necessary to identify the implant shell type patients have received. Therefore, an immediate, reliable method for identifying a breast implant shell type is essential. Evidence-based research and applying a real-world technique that identifies the surface topographic information of the inserted breast implants, without surgery, has become of paramount importance for breast implant physicians. Methods and Materials: A review of the medical records of 1901 patients
APA, Harvard, Vancouver, ISO, and other styles
14

Danza, Matteo, Dorina Lauritano, and Francesco Carinci. "Successful Rehabilitation of Partial Edentulous Maxilla and Mandible with New Type of Implants: Molecular Precision Implants." Case Reports in Medicine 2014 (2014): 1–8. http://dx.doi.org/10.1155/2014/307364.

Full text
Abstract:
The extraction of teeth results in rapid bone resorption both vertically and horizontally in the first month. The loss of alveolar ridge reduces the chance of implant rehabilitation. Atraumatic extraction, implant placement in extraction socket, and an immediate prosthesis have been proposed as alternative therapies to maintain the volume and contours tissue and reduce time and cost of treatment. The immediate load of implants is a universally practiced procedure; nevertheless a successful procedure requires expertise in both the clinical and the reconstructive stages using a solid implant sys
APA, Harvard, Vancouver, ISO, and other styles
15

Cohen, Omer, Dieter D. Bosshardt, Evegeny Weinberg, Gil Slutzkey, and Ofer Moses. "The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium." Materials 14, no. 10 (2021): 2645. http://dx.doi.org/10.3390/ma14102645.

Full text
Abstract:
Background: Stress concentrated at an implant’s neck may affect bone-to-implant contact (BIC). The objective of this study was to evaluate four different implant neck designs using two different drilling protocols on the BIC. Methods: Ninety-six implants were inserted in 12 minipigs calvarium. Implants neck designs evaluated were: type 1–6 coronal flutes (CFs), 8 shallow microthreads (SMs); type 2–6 CFs,4 deep microthreads (DMs); type 3–4 DMs; type 4–2 CFs, 8 SMs. Two groups of forty-eight implants were inserted with a final drill diameter of 2.8 mm (DP1) or 3.2 mm (DP2). Animals were sacrific
APA, Harvard, Vancouver, ISO, and other styles
16

Lixandru, Cosmin Ionuț. "RETROSPECTIVE STUDY ON THE INFLUENCE OF THE TYPE OF PROSTHETIC MATERIAL ON THE LEVELS OF BONE RESORPTION AROUND DENTAL IMPLANTS." Romanian Journal of Oral Rehabilitation 16, no. 4 (2024): 100–107. https://doi.org/10.62610/rjor.2024.4.16.10.

Full text
Abstract:
Aim of the study: The aim of the study was to evaluate the influence and impact that types of prosthetic materials can have on levels of bone resorption around dental implants. Materials and methods: This retrospective study was conducted between January 1, 2016 and December 31, 2023 at a private dental clinic in the city of Sibiu, Romania. The realization of the study involved the detailed analysis of the medical records of the patients who came to the clinic during this period of time for complex implanto-prosthetic rehabilitation. The results of this study were obtained by the analysis of a
APA, Harvard, Vancouver, ISO, and other styles
17

Referendaru, Alexandru Daniel, Anca Iuliana Popescu, Iasmin Mirea, Stefania Andrada Iancu, Raluca Monica Comaneanu, and Horia Mihail Barbu. "Experimental Studies Regarding the Distribution of the Masticatory Pressures According to the Turn�s Length of the Dental Implants." Revista de Chimie 71, no. 8 (2020): 304–12. http://dx.doi.org/10.37358/rc.20.8.8303.

Full text
Abstract:
In order to study comparatively the behaviour of the bone-implant interface at mechanical stresses depending on the length of the implant turns, we chose a complex case, a total bimaxillary edentate. 7 implants were virtually inserted into the maxilla (2 pterigoid implants in the lateral regions and 3 implants in the frontal region), and 4 implants were inserted into the mandible (two in the premolar regions and two corresponding to the canines). The FEA analyzes were performed separately for the maxilla and for the mandible, applying a force of 200N on each type of implant. The critical areas
APA, Harvard, Vancouver, ISO, and other styles
18

Matsuoka, Takashi, Tamaki Nakano, Satoshi Yamaguchi, et al. "Effects of Implant–Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis." Materials 14, no. 9 (2021): 2421. http://dx.doi.org/10.3390/ma14092421.

Full text
Abstract:
The attainment of a good aesthetic outcome in dental implant treatment requires inter-implant papilla reconstruction, which is very difficult to perform. Maintenance of the inter-implant bone is essential for maintenance of the inter-implant papilla. The aim of this study was to investigate the mechanical influences of the implant–abutment connection type and inter-implant distance on the inter-implant bone by using three-dimensional finite element analysis. Three computer-aided design models of two-piece implants were designed: external connection (EC), internal connection (IC), and conical c
APA, Harvard, Vancouver, ISO, and other styles
19

Bae, Eun-Bin, So-Hyoun Lee, Young-Chan Jeon, et al. "Effect of neck design on peri-implant tissue responses in external connection type implant : a prospective pilot clinical study." Journal of The Korean Dental Association 55, no. 11 (2017): 766–76. http://dx.doi.org/10.22974/jkda.2017.55.11.002.

Full text
Abstract:
This clinical study was conducted to evaluate the clinical effects of a concave neck of external connection type implant fixture designed for platform switching on the peri-implant tissue responses. Two types of implants with different neck designs were implanted in 20 patients. For the experimental group, the bioseal(BS) implant fixtures with 's' shaped concave profile on the neck were used, and non-bioseal(NBS) implant fixtures with a straight profile on the neck were used as control(Total of 40 implants, NBS: n = 19, BS: n=21). During the one-year period after implant placement, implant sur
APA, Harvard, Vancouver, ISO, and other styles
20

Agustín-Panadero, Rubén, Irene Bermúdez-Mulet, Lucía Fernández-Estevan, et al. "Peri-Implant Behavior of Tissue Level Dental Implants with a Convergent Neck." International Journal of Environmental Research and Public Health 18, no. 10 (2021): 5232. http://dx.doi.org/10.3390/ijerph18105232.

Full text
Abstract:
Introduction: The aim of this retrospective study was to analyze the radiographic peri-implant bone loss of bone level implants and tissue level implants with a convergent neck in screw-retained single crowns and in screw-retained fixed partial prostheses, after two years of functional loading. Materials and methods: The sample was divided into two groups according to their type: Group I: supracrestal implants with convergent transmucosal neck; Group II: crestal implants. In each group we distinguish two subgroups according to the type of prosthetic restoration: single crowns and a three-piece
APA, Harvard, Vancouver, ISO, and other styles
21

Oh, Ji-Hwan, Se-Wook Pyo, Jae-Seung Chang, and Sunjai Kim. "Up to a 15-Year Survival Rate and Marginal Bone Resorption of 1780 Implants with or without Microthreads: A Multi Center Retrospective Study." Journal of Clinical Medicine 12, no. 6 (2023): 2425. http://dx.doi.org/10.3390/jcm12062425.

Full text
Abstract:
The effect of microthreads at the implant neck on the amount of marginal bone resorption is controversial. This multicenter retrospective study compared the implant survival rate and amount of marginal bone resorption between two platform-switching internal connection implant systems with or without microthreads. Patient-related (age and sex), surgery-related (implant installation site, type, diameter, and length), and prosthesis-related (prosthesis type) data were collected from patient charts from the implant placement surgery to the final recall visit. A total of 1780 implants, including 13
APA, Harvard, Vancouver, ISO, and other styles
22

Rismanchian, Mansour, Bijan Movahedian Attar, Sayed Mohammad Razavi, Ali Nasir Shamsabad, and Majid Rezaei. "Dental Implants Immediate Loading Versus the Standard 2-Staged Protocol: An Experimental Study in Dogs." Journal of Oral Implantology 38, no. 1 (2012): 3–10. http://dx.doi.org/10.1563/aaid-joi-d-09-00104.1.

Full text
Abstract:
The endeavors to shorten implant treatment time have led to the concept of immediate loading. This research was designed to compare the immediate loading and the 2-staged methods on implant placement from a clinical, histological, and histomorphometric standpoint. Three months postextraction of 12 premolars of 3 dogs, 12 implants were inserted. Bone-implant contact (BIC), implant stability quotient (ISQ), the bone type in a 2-mm periphery around the implant, and the marginal bone loss (MBL) were recorded for unloaded implants (n = 6) and immediately loaded ones (n = 6). BIC, ISQ, MBL in the me
APA, Harvard, Vancouver, ISO, and other styles
23

Choi, Hyunsuk, and Min-Ho Hong. "Implant Restoration Using a New Cementless Screw-Retained Type Prosthetic (TDP) System: Case Series." Prosthesis 5, no. 2 (2023): 368–77. http://dx.doi.org/10.3390/prosthesis5020027.

Full text
Abstract:
The biological factors of dental implants have a significant impact on long-term prognosis. In the cement-retained type or screw cement-retained type prosthesis (SCRP) implants, dental luting cement is used between the abutment and the implant fixture. Residual excess cement remaining around the implant and gingiva is one of the major causes of peri-implantitis, which is the most common cause of late implant failure. The TDP implant prosthetic system is a new cementless screw-retained type prosthetic system, which overcomes the limitations of the conventional implant prosthetic systems. Using
APA, Harvard, Vancouver, ISO, and other styles
24

Demirci, Fatih, and Abdulsamet Tanık. "Evaluation of the demographic profile of patients with implant-supported fixed dental prostheses: A retrospective clinical study." International Dental Research 11, no. 3 (2021): 165–71. http://dx.doi.org/10.5577/intdentres.2021.vol11.no3.5.

Full text
Abstract:
Aim: In this study, the aim is to evaluate the demographic profile as well as clinical aspects of patients who received implant-supported fixed dental prostheses (FDP) between 2016 and 2019 years.
 Methodology: Among 150 patients with implant-supported FDP, 120 contacted patients were included in the study. The patients were examined in terms of gender, age groups, edentulism, restoration type, implant location, implant survival rate, and abutment type by using the computer software. Data results were analyzed by descriptive statistical methods.
 Results: Three hundred and six dental
APA, Harvard, Vancouver, ISO, and other styles
25

Melenekiotis, Andrew Sotirios, Rubens Moreno de Freitas, Marcos Boaventura Moura, et al. "Influence of bone quality on success and bone level changes around platform-switched morse taper connection implants supporting fixed partial prostheses: a one-year prospective clinical study." Journal of Orofacial Innovation and Science 1, no. 1 (2024): 10–18. https://doi.org/10.63281/jois.v1i1.2.

Full text
Abstract:
Evaluate the influence of bone quality on success and bone level changes around Morse taper implants with platform-switchingsupporting fixed partial prostheses, within one year after implant placement. Platform-switched Morse taper connection implants with hydrophilic surfaces were placed to support metal-ceramic prostheses. Bone quality was surgically assessed by the surgeons according to their perception of resistance during implant site preparation and confirmed on periapical radiography. Implants were divided into two groups: bone type I/II and bone type III/IV. To evaluate bone level chan
APA, Harvard, Vancouver, ISO, and other styles
26

Di Lorenzo, Matteo, Andrea Torsani, Paolo Tonveronachi, Samuele Baruch, and Christian Caldari. "Risk factors for early implant failure: a retrospective-multicentric study of 2323 implants in screw retained fixed full arch rehabilitation." Journal of Oral Medicine and Oral Surgery 29, no. 2 (2023): 24. http://dx.doi.org/10.1051/mbcb/2023022.

Full text
Abstract:
Objectives: The aim of this retrospective study was to investigate possible risk factors for early implant failure in screw retained fixed full-arch rehabilitation. Methods: data of 487 patients (2323 implants) treated with full-arch rehabilitation supported by same implants brand were collected for the time period from 2017 to 2020 and examined to evaluate early implants failure rates. The following data were collected for statistical analysis: sex, age, health disorders (diabetes and hypertension) and bad habit (smoke) of the patient, location of the implant (maxilla or mandible, anterior or
APA, Harvard, Vancouver, ISO, and other styles
27

Moeintaghavi, Amir, Mehrdad Radvar, Hamid Reza Arab, Hamid Reza Boostani, and Elham Ghiami. "Evaluation of 3- to 8-Year Treatment Outcomes and Success Rates With 6 Implant Brands in Partially Edentulous Patients." Journal of Oral Implantology 38, S1 (2012): 441–48. http://dx.doi.org/10.1563/aaid-joi-d-10-00117.

Full text
Abstract:
The use of osseointegrated implants as a foundation for the prosthetic replacement of missing teeth has become widespread, with new dental implant systems being introduced every year. There is growing interest in identifying the factors associated with implant failure, such as implant type. This study was designed to establish the relationship between implant type and success. Eighty-eight patients (mean age, 52 years) with 268 implants (110 BioHorizons, 60 ITI, 60 Paragon, 18 Xive, six 3i, and 19 Allfit) participated in this 5-year retrospective study. Statistical significance was defined for
APA, Harvard, Vancouver, ISO, and other styles
28

Vicente Neto, Pedro, Ana Lúcia Franco Micheloni, Cássio Rocha Scarduelli, Karina Eiras Dela Coleta Pizzol, Francisco De Assis Mollo Júnior, and Elcio Marcantônio Júnior. "Predictability and success rate of short implants." Journal of Research in Dentistry 5, no. 2 (2018): 28. http://dx.doi.org/10.19177/jrd.v5e2201728-31.

Full text
Abstract:
In oral rehabilitation with dental implants, severely resorbed alveolar ridges are a challenging problem due to the reduced height of the residual bone. Continuous search for minimally invasive procedures has resulted in the conception of reduced-length dental implants, decreasing the necessary amount of bone for implantation, thereby reducing the need of bone-grafts. Given the growing demand in the field of implant dentistry and the continuous development of surgical techniques, this study aimed to review the current literature on the predictability and success rate of short implants. Relevan
APA, Harvard, Vancouver, ISO, and other styles
29

Yu, Jian, Chao Zhang, Wen-Ming Chen, et al. "Finite-element analysis of the influence of tibial implant fixation design of total ankle replacement on bone–implant interfacial biomechanical performance." Journal of Orthopaedic Surgery 28, no. 3 (2020): 230949902096612. http://dx.doi.org/10.1177/2309499020966125.

Full text
Abstract:
Purpose: Implant loosening in tibia after primary total ankle replacement (TAR) is one of the common postoperative problems in TAR. Innovations in implant structure design may ideally reduce micromotion at the bone–implant interface and enhance the bone-implant fixation and initial stability, thus eventually prevents long-term implant loosening. This study aimed to investigate (1) biomechanical characteristics at the bone–implant interface and (2) the influence of design features, such as radius, height, and length. Methods: A total of 101 finite-element models were created based on four comme
APA, Harvard, Vancouver, ISO, and other styles
30

Soegiantho, Patricia, Patricia Gillian Suryawinata, Wendy Tran, et al. "Survival of Single Immediate Implants and Reasons for Loss: A Systematic Review." Prosthesis 5, no. 2 (2023): 378–424. http://dx.doi.org/10.3390/prosthesis5020028.

Full text
Abstract:
Background: Immediate implant placement (IIP) or Type I implants have become more attractive than conventional implant placements as it reduces the number of surgical procedures and allows faster delivery of the final restoration compared to conventional implant placements. However, the survival of Type I implants varies depending on multiple factors. Purpose: To evaluate the survival rate of Type I implants, and to describe the factors influencing their failure. Materials and methods: A developed search strategy was applied to identify randomised controlled trials on single-unit immediate imp
APA, Harvard, Vancouver, ISO, and other styles
31

Bordin, Dimorvan, Mariane Boaventura de Castro, Marco Aurélio de Carvalho, Anderson Macena de Araujo, Altair Antoninha Del Bel Cury, and Priscilla Cardoso Lazari-Carvalho. "Different Treatment Modalities Using Dental Implants in the Posterior Maxilla: A Finite Element Analysis." Brazilian Dental Journal 32, no. 1 (2021): 34–41. http://dx.doi.org/10.1590/0103-6440202103890.

Full text
Abstract:
Abstract The objective of this study was to compare the biomechanical behavior of peri-implant bone tissue and prosthetic components in two modalities of treatment for posterior region of the maxilla, using short implants or standard-length implants associated with bone graft in the maxillary sinus. Four 3D models of a crown supported by an implant fixed in the posterior maxilla were constructed. The type of implant: short implant (S) or standard-length implant with the presence of sinus graft (L) and type of crown retention: cemented (C) or screwed (S) were the study factors. The models were
APA, Harvard, Vancouver, ISO, and other styles
32

Al Saleh, Fatma, Moosa AbuZayeda, Sudarat Kiat-amnuay, and Alexander Milosevic. "Survey of Dental Implant and Restoration Selection by Prosthodontists in Dubai." International Journal of Dentistry 2021 (August 17, 2021): 1–8. http://dx.doi.org/10.1155/2021/8815775.

Full text
Abstract:
Background. With various surgical and prosthetic component designs being introduced in dental implants, decisions have to be made when choosing a system and a certain prosthodontic protocol. A survey of implant prosthodontic specialists has not been previously performed in the Middle East. Aim. This study aimed to determine selection criteria and choice of dental implants and restorations by prosthodontic specialists in the Emirate of Dubai, United Arab Emirates. Materials and Methods. A validated 16-item questionnaire was used in the survey which included demographic information, implant trai
APA, Harvard, Vancouver, ISO, and other styles
33

Alemayehu, Dawit Bogale, Masahiro Todoh, and Song-Jeng Huang. "Nonlinear Finite Element Analysis of Bone–Implant Contact in Three Short Dental Implant Models with Varying Osseointegration Percentages." Oral 4, no. 4 (2024): 505–24. http://dx.doi.org/10.3390/oral4040040.

Full text
Abstract:
Objectives: Dental implants have become a cornerstone of restorative dentistry, providing a long-lasting method for tooth replacement. The degree of osseointegration has a significant effect on biomechanical stability at the bone–implant contact (BIC), determining the continued efficacy of these implants. However, the exact consequences of changing osseointegration levels on different implant designs, especially in bones with variable densities, are not well known. Methods: This study used 3D finite element analysis (FEA) to look at the biomechanical performance of three short dental implants:
APA, Harvard, Vancouver, ISO, and other styles
34

Cosola, Saverio, Andrea Butera, Abenezer Hailu Zergaw, et al. "Glycemic Control and Implant Stability in Patients with Type II Diabetes: Narrative Review." Healthcare 13, no. 5 (2025): 449. https://doi.org/10.3390/healthcare13050449.

Full text
Abstract:
Advancements in implant design, surface characteristics, and surgical protocols have made implant restorations safe and highly predictable procedures. Bone metabolism plays a central role in the success of implant therapy. Diabetes mellitus is a significant disease impacting bone metabolism, particularly during the initial stages of osseointegration and in long-term survival. Moreover, aging is linked to various systemic conditions, such as diabetes, which increase the susceptibility of the periodontium and teeth to disease, often resulting in tooth loss. Studies on the impact of glycemic cont
APA, Harvard, Vancouver, ISO, and other styles
35

Soni, Suman, Anees Shahnawaz, Kumar Sharma Sushant, Kumar Bhartendu, and Choudhary V.P. "Comparative Analysis of Saline and Silicone Gel Implants in Subpectoral Breast Augmentation: A Prospective Study." International Journal of Pharmaceutical and Clinical Research 15, no. 12 (2023): 1783–88. https://doi.org/10.5281/zenodo.11207160.

Full text
Abstract:
<strong>Background:</strong>&nbsp;Breast augmentation is a popular cosmetic procedure with a critical choice between saline and silicone gel implants, each offering distinct advantages and disadvantages. This study aimed to provide objective data comparing these two implant types, shedding light on their complications, patient satisfaction, and aesthetic outcomes.&nbsp;<strong>Methods:</strong>&nbsp;Over a 1-year period, 120 women underwent primary cosmetic breast augmentation, with data collected through clinical evaluations, surveys, and ultrasound scans. Complication rates, implant characte
APA, Harvard, Vancouver, ISO, and other styles
36

Szpak, Piotr, and Jolanta Szymanska. "The Relationship Between Marginal Bone Loss Around Dental Implants and the Specific Characteristics of Implant-Prosthetic Treatment." Current Issues in Pharmacy and Medical Sciences 31, no. 2 (2018): 97–100. http://dx.doi.org/10.1515/cipms-2018-0019.

Full text
Abstract:
Abstract The marginal bone loss around dental implants is an important indicator that helps to evaluate the course and the final outcome of implant-prosthetic treatment. It is, therefore, important to understand the factors that may affect this. The aim of the study was to assess the impact of the specific characteristics of implant-prosthetic treatment on the marginal bone loss around implants. The study included 28 patients, aged 37-66 years, treated with dental implants. Every patient received at least one of the two types of implants: with Morse taper connection and with internal hexagonal
APA, Harvard, Vancouver, ISO, and other styles
37

Dayan, Cagatay, Onur Geckili, and Canan Bural. "The Influence of Implant Shape on Primary Stability of Implants With a Thread Cutting and Forming Design: An Ex Vivo Study." Journal of Oral Implantology 45, no. 3 (2019): 181–85. http://dx.doi.org/10.1563/aaid-joi-d-18-00158.

Full text
Abstract:
The design of an implant has a great effect on primary stability. The purpose of this study was to determine the differences in primary stability between straight and tapered Neoss ProActive implants in type I and type III bones using resonance frequency analysis (RFA) and electronic percussive testing (EPT) methods. Fresh cow vertebrae and pelvis were used as models of type III and type i bone, respectively. Implants of 2 different designs—straight and tapered Neoss ProActive implants with a thread cutting and forming (TCF) design, both 3.5-mm wide and 11-mm long—were placed in both types of
APA, Harvard, Vancouver, ISO, and other styles
38

Mude, Madhusudana Naik. "Breast implant rupture: removal and re-implantation: a dual case report." International Surgery Journal 12, no. 2 (2025): 218–21. https://doi.org/10.18203/2349-2902.isj20250150.

Full text
Abstract:
Breast implant surgery is now among the top five plastic surgeries done for cosmetic purpose globally. Silicone implants are the most common type of implants used whereas saline implants are used by very few. In the long run, rupture of the breast implant is a complication of these kind of surgeries. As per one study, over a period of 3-20 years, the silicone implants are likely to rupture. After three years of the breast implant surgery, it has been estimated that the survival rate for the silicone breast implants is around 83-85%. Some implant ruptures are silent or asymptomatic. Early diagn
APA, Harvard, Vancouver, ISO, and other styles
39

Doornewaard, Ron, Maarten Glibert, Carine Matthys, Stijn Vervaeke, Ewald Bronkhorst, and Hugo de Bruyn. "Improvement of Quality of Life with Implant-Supported Mandibular Overdentures and the Effect of Implant Type and Surgical Procedure on Bone and Soft Tissue Stability: A Three-Year Prospective Split-Mouth Trial." Journal of Clinical Medicine 8, no. 6 (2019): 773. http://dx.doi.org/10.3390/jcm8060773.

Full text
Abstract:
In fully edentulous patients, the support of a lower dental prosthesis by two implants could improve the chewing ability, retention, and stability of the prosthesis. Despite high success rates of dental implants, complications, such as peri-implantitis, do occur. The latter is a consequence of crestal bone loss and might be related to the implant surface and peri-implant soft tissue thickness. The aim of this paper is to describe the effect of implant surface roughness and soft tissue thickness on crestal bone remodeling, peri-implant health, and patient-centered outcomes. The mandibular overd
APA, Harvard, Vancouver, ISO, and other styles
40

Hallab, Nadim James, Lauryn Samelko, and Dennis Hammond. "Particulate Debris Released From Breast Implant Surfaces Is Highly Dependent on Implant Type." Aesthetic Surgery Journal 41, no. 7 (2021): NP782—NP793. http://dx.doi.org/10.1093/asj/sjab051.

Full text
Abstract:
Abstract Background Although breast implants (BIs) have never been safer, factors such as implant debris may influence complications such as chronic inflammation and illness such as ALCL (anaplastic large cell lymphoma). Do different types of BIs produce differential particulate debris? Objectives The aim of this study was to quantify, investigate, and characterize the size, amount, and material type of both loosely bound and adherent surface particles on 5 different surface types of commercial BIs. Methods Surface particles from BIs of 5 surface types (n = 5/group), Biocell, Microcell, Siltex
APA, Harvard, Vancouver, ISO, and other styles
41

Jeng, Ming-Dih, Po-Yi Liu, Jia-Hum Kuo, and Chun-Li Lin. "Load Fatigue Performance Evaluation on Two Internal Tapered Abutment–Implant Connection Implants Under Different Screw Tightening Torques." Journal of Oral Implantology 43, no. 2 (2017): 107–13. http://dx.doi.org/10.1563/aaid-joi-d-16-00129.

Full text
Abstract:
This study evaluates the load fatigue performance of different abutment–implant connection implant types—retaining-screw (RS) and taper integrated screwed-in (TIS) types under 3 applied torque levels based on the screw elastic limit. Three torque levels—the recommended torque (25 Ncm), 10% less, and 10% more than the ratio of recommended torque to screw elastic limits of different implants were applied to the implants to perform static and dynamic testing according to the ISO 14801 method. Removal torque loss was calculated for each group after the endurance limitation was reached (passed 5 ×
APA, Harvard, Vancouver, ISO, and other styles
42

Madi, Marwa, Osama Zakaria, and Shohei Kasugai. "Coated vs Uncoated Implants: Bone Defect Configurations After Progressive Peri-implantitis in Dogs." Journal of Oral Implantology 40, no. 6 (2014): 661–69. http://dx.doi.org/10.1563/aaid-joi-d-12-00089.

Full text
Abstract:
In this study, hydroxyapatite coated vs uncoated implants were used to evaluate the type and dimensions of bone defects after progressive peri-implantitis in dogs. Thirty-two dental implants with 4 different surfaces—machined (M), sandblasted acid-etched (SA), 1-μm thin sputter hydroxyapatite (HA)-coated (S), and plasma-sprayed HA-coated (P)—were inserted into the mandibles of 4 beagle dogs after extracting all mandibular premolars. Experimental peri-implantitis was induced after 3 months using ligature to allow for plaque accumulation. After 4 months, ligatures were removed and plaque accumul
APA, Harvard, Vancouver, ISO, and other styles
43

Anitua, Eduardo, Adriana Montalvillo, Asier Eguia, and Mohammad Hamdan Alkhraisat. "Clinical Performance of Extra-Short (≤5.5 mm) Compared to Longer Implants Splinted under the Same Prosthesis: A Randomized Clinical Trial." Dentistry Journal 12, no. 9 (2024): 292. http://dx.doi.org/10.3390/dj12090292.

Full text
Abstract:
Objective: This randomized controlled split-mouth trial compared the performance of 5.5 mm length implants (test group; TG) splinted within the same fixed prosthesis as longer implants (≥6.5 mm; control group; CG) in posterior regions. Methods: The primary hypothesis was that implant length does not affect marginal bone loss (MBL) one year post-implantation, while the secondary hypotheses included implant survival, peri-implant clinical variables, and prosthetic complications. Fifteen patients (eight males, seven females) with a mean age of 67 ± 9 years were included. Results: No significant d
APA, Harvard, Vancouver, ISO, and other styles
44

Calvo-Guirado, Jose Luis, Nuria García Carrillo, Félix de Carlos-Villafranca, et al. "A micro-CT evaluation of bone density around two different types of surfaces on one-piece fixo implants with early loading-an experimental study in dogs at 3 months." AIMS Bioengineering 9, no. 4 (2022): 383–99. http://dx.doi.org/10.3934/bioeng.2022028.

Full text
Abstract:
&lt;abstract&gt; &lt;p&gt;The study's main objective was to evaluate the bone density and osseointegration around dental implants with two different implant surfaces with early loading, using a micro-CT device. Twenty-four Fixo® implants (Oxyimplant, Biomec Italy) 3.5 × 8.5 mm with Laser (test group) and acid-etched surface (control group) were placed in six young beagle dog's mandibles. MicroCT (Albira, Germay) evaluation with seven regions of interest was defined in each implant on two different surfaces. A total of 168 sites were studied, and four isocountours were also done in each implant
APA, Harvard, Vancouver, ISO, and other styles
45

Iglesias, Nicholas J., Vasudev Vivekanand Nayak, Arthur Castellano, et al. "The Effect of Three-Dimensional Stabilization Thread Design on Biomechanical Fixation and Osseointegration in Type IV Bone." Biomimetics 10, no. 6 (2025): 395. https://doi.org/10.3390/biomimetics10060395.

Full text
Abstract:
Achieving the appropriate primary stability for immediate or early loading in areas with low-density bone, such as the posterior maxilla, is challenging. A three-dimensional (3D) stabilization implant design featuring a tapered body with continuous cutting flutes along the length of the external thread form, with a combination of curved and linear geometric surfaces on the thread’s crest, has the capacity to enhance early biomechanical and osseointegration outcomes compared to implants with traditional buttressed thread profiles. Commercially available implants with a buttress thread design (T
APA, Harvard, Vancouver, ISO, and other styles
46

Mahajan, Ankit, Jyoti Kumari, Mohammed Ahsan Razi, Ria Sahay, Isha Badalia, and Tannu Priya. "A Cross-sectional Study Examining the Effects of Periodontitis, Implant, and Prosthesis Characteristics on the Peri-implant Status." Journal of Pharmacy and Bioallied Sciences 17, Suppl 2 (2025): S1565—S1567. https://doi.org/10.4103/jpbs.jpbs_138_25.

Full text
Abstract:
ABSTRACT Background: Implant design, prosthesis features, and pre-existing periodontitis all have a big impact on peri-implant state. To increase implant lifetime and guarantee ideal peri-implant health, it is essential to comprehend these elements. Materials and Methods: One hundred and fifty dental implant patients participated in cross-sectional research. The participants were divided into three groups according to their history of periodontal disease: healthy, treated, and untreated. The prosthesis type (cement-retained or screw-retained) and implant attributes (length, diameter, and surfa
APA, Harvard, Vancouver, ISO, and other styles
47

EL-KHOURY, Nadim, Gabriel MENASSA, Carole CHAKAR, Abdel Rahman KASSIR, and Nada NAAMAN. "Clinical and Radiographic evaluation of bone remodeling around implants placed in horizontally augmented bone: A Pilot Study." International Arab Journal of Dentistry 14, no. 2 (2023): 112–19. http://dx.doi.org/10.70174/iajd.v14i2.936.

Full text
Abstract:
Introduction: Marginal bone loss after implant placement is one of the most used criteria to assess the success of osseointegrated implants over time. The type of implant connection and implant surface type are reported to have an influence on bone remodeling around the placed implants. This study aimed to evaluate marginal bone loss around two implant systems with different connections and surfaces in horizontally augmented sites. Methods: This randomized control pilot study included 8 implants placed in 3 patients who needed implant placement in previously horizontally grafted sites. The pla
APA, Harvard, Vancouver, ISO, and other styles
48

Kalidindi, S. R., and P. Ahmad. "A Numerical Investigation of the Mechanics of Swelling-Type Intramedullary Hip Implants." Journal of Biomechanical Engineering 119, no. 3 (1997): 241–47. http://dx.doi.org/10.1115/1.2796087.

Full text
Abstract:
The novel concept of swelling-type intramedullary hip implants that attain self-fixation by an expansion-fit mechanism resulting from controlled swelling of the implant (by absorption of body fluids) was examined in detail using a finite element model of the implant-femur system. Some of the potential advantages of this technique over traditional techniques include enhanced fixation, lower relative micromotions, improved bony ingrowth, and elimination of acrylic cement. The finite element model created in this study incorporated: (i) the major aspects of the three-dimensional geometry of the i
APA, Harvard, Vancouver, ISO, and other styles
49

Marinelli, Grazia, Angelo Michele Inchingolo, Claudio Carone, et al. "Impact of diabetes and prediabetes on dental implant success: a comprehensive review." Oral & Implantology 16, no. 3.2suppl (2024): 760–76. https://doi.org/10.11138/oi.v16i3.2suppl.142.

Full text
Abstract:
Dental implants are a standard solution for tooth loss, but their success is influenced by systemic conditions such as diabetes mellitus (DM) and prediabetes. These conditions can affect bone metabolism, immune function, and wound healing, all essential for implant integration and stability. This narrative review examines the impact of DM and prediabetes on dental implant outcomes, focusing on osseointegration, peri-implant health, implant survival, and post-surgical complications. DM, including Type 1 and Type 2, is characterized by chronic hyperglycemia due to insulin dysfunction. Poor glyce
APA, Harvard, Vancouver, ISO, and other styles
50

Kızılırmak, Burcu, Neslihan Güntekin, Reza Mohammadi, Meryem Erdoğdu, and Ali Rıza Tunçdemir. "Investigation of the effect of implant crown ratio and material type on the force transmitted to the implant in implant-supported restorations: a finite element analysis study." Journal of Health Sciences and Medicine 7, no. 6 (2024): 604–9. https://doi.org/10.32322/jhsm.1535336.

Full text
Abstract:
Aims: The crown implant ratio may pose a problem, especially when short implants are used. This condition is associated with marginal bone loss. Therefore, in this study, it was aimed to evaluate the stresses arising from the bone, implant and its parts and the restoration by finite element analysis (FEA), as a result of comparing a situation with ideal bone support and a similar situation with vertical bone loss. The null hypothesis is that the type of material and crown length chosen for implant-supported restorations will not make a difference in terms of stress on implants of different siz
APA, Harvard, Vancouver, ISO, and other styles
We offer discounts on all premium plans for authors whose works are included in thematic literature selections. Contact us to get a unique promo code!